HomeMy WebLinkAbout1944 Village Cir - BuildingLinda Pangrle
From. Ken Dubuc
Sent: Thursday August 11 2011 10'45 AM
To Linda Pangrle
Subject: inspections
Linda,
Here is some info for you
1925 Village Circle 10 -1514
1929 Village Circle 10 -1513
1933 Village Circle 11 -78
1940 Village Circle 11 -125
1944 Village Circle 11 -12G.:.
1119 Village Place 11 -276
1123 Village Place 11 -277
All of these were finaled on 7 22 2011
Thanks,
Ken
1
PREPARED 7/27/11 8 10 52 INSPECTION TICKET PAGE 9
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 7/27/11
ADDRESS 1944 VILLAGE CIR SUBDIV
TENANT NBR STEPHANIE HOLCOMB
CONTRACTOR PHONE
OWNER STEPHANIE HOLCOMB PHONE
PARCEL 06 30 13 5 7 0270 0000
APPL NUMBER 10 00000513 RES NEW SFR
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
PL6 01 12/02/10 JLL
12/02/10 AP
PL2 01 3/09/11 JLL
3/09/11 AP
PL99 01 7/27/11
PLUMBING WATER SUPPLY
December 1 2010 3 58 26 PM 1pangrle
BRUCE 912 0079
WATER SUPPLY LINE METER TO BLDG
December 2 2010 4 16 30 PM jlierly
PLUMBING ROUGH IN
March 9 2011 8 21 45 AM 1pangrle
JOHN 460 6902
ROUGH IN PLUMBING
March 9 2011 4 51 59 PM jlierly
PLUMBING FINAL
July 26 2011 9 31 56 AM 1pangrle
BRUCE 912 0079
PLUMBING FINAL
COMMENTS AND NOTES
PREPARED 7/27/11 8 10 52
CITY OF PORT ANGELES
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
PERMIT PL 00 PLUMBING PERMIT
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
INSPECTION TICKET
INSPECTOR JAMES LIERLY
ADDRESS 1944 VILLAGE CIR SUBDIV
TENANT NBR STEPHANIE HOLCOMB
CONTRACTOR PHONE
OWNER STEPHANIE HOLCOMB PHONE
PARCEL 06 30 13 5 7 0270 0000
APPL NUMBER 10 00000513 RES NEW SFR
FRAMING RIM JOIST TOE NAILS
MORNING
December 21 2010 8 41 32 AM pbarthol
BL9 01 2/18/11 JLL BLDG SHEARWALL
2/18/11 AP February 18 2011 8 43 04 AM 1pangrle
BRUCE 912 0079
SHEARWALL
February 18 2011 4 51 57 PM jlierly
BL3 03 4/14/11 PB BLDG FRAMING
4/15/11 AP April 14 2011 8 20 23 AM 1pangrle
BRUCE 912 0079
FRAMING
April 15 2011 8 48 33 AM pbarthol
BAIR 01 4/20/11 JLL BLDG AIR SEAL
4/20/11 AP April 20 2011 8 31 26 AM 1pangrle
BRUCE 912 0079
AIRSEAL
April 20 2011 3 57 25 PM jlierly
BLI 01 4/22/11 JLL BLDG INSULATION
4/22/11 AP April 22 2011 8 19 51 AM 1pangrle
BRUCE 912 0079
WALL INSULATION
April 22 2011 4 09 54 PM jlierly
BLDR 01 4/27/11 JLL BLDG DRYWALL IBWP
4/27/11 AP April 27 2011 8 09 55 AM 1pangrle
BRUCE 912 0079
IBWP
April 27 2011 4 22 52 PM jlierly
PW99 01 7/19/11 RV PUBLIC WORKS FINAL
7/19/11 AP Agg July 20 2011 7 19 43 AM rvess
July 20 2011 7 20 04 AM rvess
BL99 01 7/27/11 BLDG FINAL
July 26 2011 9 31 18 AM 1pangrle
BRUCE 912 0079
BUILDING FINAL
PERMIT ME 00 MECHANICAL PERMIT
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
ME99 01 7/27/11
MECHANICAL FINAL
July 26 2011 9 31 36 AM 1pangrle
BRUCE 912 0079
MECHANICAL FINAL
CONTINUED ONTO NEXT PAGE
PAGE 8
DATE 7/27/11
PREPARED 4/27/11 8 12 45
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY
ADDRESS 1944 VILLAGE CIR
TENANT NBR STEPHANIE HOLCOMB
CONTRACTOR
OWNER
PARCEL
APPL NUMBER
BL3 03 4/14/11 PB
4/15/11 AP
BAIR 01
BLDR 01 4/27/11
STEPHANIE HOLCOMB
06 30 13 5 7 0270 0000
10 00000513 RES NEW SFR
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
BL9 01 2/18/11 JLL
2/18/11 AP
4/20/11 JLL
4/20/11 AP
BLI 01 4/22/11 JLL
4/22/11 AP
INSPECTION TICKET
FRAMING RIM JOIST
MORNING
December 21 2010 8
BLDG SHEARWALL
February 18 2011 8
BRUCE 912 0079
SHEARWALL
February 18 2011 4
BLDG FRAMING
April 14. 2011 8 20
BRUCE 912 0079
FRAMING
April 15 2011 8 48
BLDG AIR SEAL
April 20 2011 8 31
BRUCE 912 0079
AIRSEAL
April 20 2011 3 57
BLDG INSULATION
April 22 2011 8 19
BRUCE 912 0079
WALL INSULATION
April 22 2011 4 09
BLDG DRYWALL IBWP
April 27 2011 8 09
BRUCE 912 0079
IBWP
SUBDIV
PHONE
PHONE
COMMENTS AND NOTES
TOE NAILS
41 32 AM pbarthol
43 04 AM 1pangrle
51 57 PM jlierly
23 AM 1pangrle
33 AM pbarthol
26 AM 1pangrle
25 PM jlierly
51 AM 1pangrle
54 PM jlierly
55 AM 1pangrle
PAGE 2
DATE 4/27/11
PREPARED 4/22/11 8 22 12 INSPECTION TICKET
CITY OF PORT ANGELES
ADDRESS
TENANT NBR
CONTRACTOR
OWNER
PARCEL
APPL NUMBER
REQUESTED
TYP /SQ COMPLETED
BL9 01 2/18/11
2/18/11
BL3 03 4/14/11
4/18/11
BAIR 01 4/20/11
4/20/11
1944 VILLAGE CIR
STEPHANIE HOLCOMB
STEPHANIE HOLCOMB
06 30 13 5 7 0270 0000
10 00000513 RES NEW SFR
INSP DESCRIPTION
RESULT RESULTS /COMMENTS
JLL
AP
PB
AP
JLL
AP
INSPECTOR JAMES LIERLY
FRAMING RIM JOIST
MORNING
December 21 2010 8
BLDG SHEARWALL
February 18 2011 8
BRUCE 912 0079
SHEARWALL
February 18 2011 4
BLDG FRAMING
April 14 2011 8 20
BRUCE 912 0079
FRAMING
April 15 2011 8 48
BLDG AIR SEAL
April 20 2011 8 31
BRUCE 912 0079
AIRSEAL
April 20 2011 3 57
BLDG INSULATION
April 22 2011 8 19
BRUCE 912 0079
WALL INSULATION
SUBDIV
PHONE
PHONE
COMMENTS AND NOTES
TOE NAILS
41 32 AM pbarthol
43 04 AM 1pangrle
51 57 PM jlierly
23 AM 1pangrle
33 AM pbarthol
26 AM 1pangrle
25 PM jlierly
51 AM 1pangrle
PAGE 2
DATE 4/22/11
PREPARED 4/20/11 8 32 55 INSPECTION TICKET
CITY OF PORT ANGELES
ADDRESS 1944 VILLAGE CIR
TENANT NBR STEPHANIE HOLCOMB
CONTRACTOR
OWNER
PARCEL
APPL NUMBER
REQUESTED
TYP /SQ COMPLETED
BL3 03 4/14/11 PB
4/15/11 AP
BAIR 01
STEPHANIE HOLCOMB
06 30 13 5 7 0270 0000
10 00000513 RES NEW SFR
BL9 01 2/18/11 JLL
2/18/11 AP
INSP DESCRIPTION
RESULT RESULTS /COMMENTS
INSPECTOR JAMES LIERLY
FRAMING
MORNING
December 21 2010
BLDG SHEARWALL
February 18 2011
BRUCE 912 0079
SHEARWALL
February 18 2011
BLDG FRAMING
April 14 2011 8
BRUCE 912 0079
FRAMING
April 15 2011 8 48
BLDG AIR SEAL
April 20 2011 8 31
BRUCE 912 0079
AIRSEAL
SUBDIV
PHONE
PHONE
RIM JOIST TOE NAILS
COMMENTS AND NOTES
8 41 32 AM pbarthol
8 43 04 AM 1pangrle
4 51 57 PM jlierly
20 23 AM 1pangrle
33 AM pbarthol
26 AM 1pangrle
PAGE 2
DATE 4/20/11
PREPARED 4/14/11 8 23 29 INSPECTION TICKET PAGE 3
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 4/14/11
ADDRESS 1944 VILLAGE CIR SUBDIV
TENANT NBR STEPHANIE HOLCOMB
CONTRACTOR PHONE
OWNER STEPHANIE HOLCOMB PHONE
PARCEL 06 30 13 5 7 0270 0000
APPL NUMBER 10 00000513 RES NEW SFR
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
BL9 01 2/18/11 JLL BLDG SHEARWALL
2/18/11 AP February 18 2011 8 43 04 AM 1pangrle
BRUCE 912 0079
SHEARWALL
February 18 2011 4 51 57 PM jlierly
BL3 03 4/14/11 JLL BLDG FRAMING
FRAMING RIM JOIST TOE NAILS
MORNING
December 21 2010 8 41 32 AM pbarthol
April 14 2011 8 20 23 AM 1pangrle
BRUCE 912 0079
FRAMING
COMMENTS AND NOTES
PREPARED 3/09/11 9 13 34 INSPECTION TICKET PAGE 9
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 3/09/11
ADDRESS 1944 VILLAGE CIR SUBDIV
TENANT NBR STEPHANIE HOLCOMB
CONTRACTOR PHONE
OWNER STEPHANIE HOLCOMB PHONE
PARCEL 06 30 13 5 7 0270 0000
APPL NUMBER 10 00000513 RES NEW SFR
PERMIT PL 00 PLUMBING PERMIT
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
PL6 01 12/02/10 JLL PLUMBING WATER SUPPLY
12/02/10 AP December 1 2010 3 58 26 PM 1pangrle
BRUCE 912 0079
WATER SUPPLY LINE METER TO BLDG
December 2 2010 4 16 30 PM jlierly
PL2 01 3/09/11 L PLUMBING ROUGH IN
March 9 2011 8 21 45 AM 1pangrle
JOHN 460 6902
ROUGH IN PLUMBING
COMMENTS AND NOTES
PREPARED 2/18/11 8 44 07 INSPECTION TICKET PAGE 3
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 2/18/11
ADDRESS 1944 VILLAGE CIR SUBDIV
TENANT NBR STEPHANIE HOLCOMB
CONTRACTOR PHONE
OWNER STEPHANIE HOLCOMB PHONE
PARCEL 06 30 13 5 7 0270 0000
APPL NUMBER 10 00000513 RES NEW SFR
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
BL9 01 2/181
FRAMING RIM JOIST TOE NAILS
MORNING
December 21 2010 8 41 32 AM pbarthol
BLDG SHEARWALL
February 18 2011 8 43 04 AM 1pangrle
BRUCE 912 0079
SHEARWALL
COMMENTS AND NOTES
Application Number
Application pin number
Property Address
ASSESSOR PARCEL NUMBER
Tenant nbr name
Application type description
Subdivision Name
Property Use
Property Zoning
Application valuation
Application desc
INSTALL A FIRE SPRINKLER SYSTEM
Owner
Fee summary
Permit Fee Total
Plan Check Total
Grand Total
CITY OF PORT ANGELES
FIRE DEPARTMENT PERMIT
321 East 5th Street, Port Angeles, WA 98362
11 00000126
221372
1944 VILLAGE CIR
06 30 13 5 7 0270 0000
STEPHANIE HOLCOMB
FIRE SPRINKLER SYSTEM
RESIDENTIAL HIGH DENSITY
1875
Contractor
Special Notes and Comments
A full acceptance test will be required for the fire
sprinkler system
Call for cover inspection for all sprinkler installations
Charged Paid Credited
00 00 00
00 00 00
00 00 00
g sL, a//610
Date 2/15/11
STEPHANIE HOLCOMB INNOVATED FIRE SPRINKLERS
1334 SAMARA DR 81 NEW HAVEN LANE
PORT ANGELES WA 98363 PORT ANGELES
(360) 670 8694 (360) 452 7583
Structure Information 000 000 FIRE SPRINKLER SYSTEM
WA 98362
Permit FIRE SPRINKLER RESIDENTIAL
Additional desc FIRE SPRINKLER SYSTEM
Permit pin number 181297
Permit Fee 00 Plan Check Fee 00
Issue Date 2/15/11 Valuation 1875
Expiration Date 8/14/11
Due
00
00
00
REPORT SALES TAX
on your state excise tax form
to the City of Port Angeles
(Location Code 0502)
This permit becomes null and void if work authorized is not commenced within 180 days, if work is suspended or
abandoned for a period of 180 days afer the work has commenced, or if required inspections have not been requested with
180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be
true and correct. All provisions of recognized standards, laws and ordinances governing this type of work will be compied
with whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel
the 3rovisions of any state or local law regulating the work specified in the permit.
Signature of Contractor or Aut`h'orized Agent Date Signature of Owner (if Owner is builder) Date
FIRE PERMIT INSPECTION RECORD
Call 360 -417 -4655 for fire inspections. Please provide a minimum 24 -hour notice It is unlawful to cover, insulate
or conceal any work before inspected and accepted. Post permit in a conspicuous location.
Inspection Type Date Passed I Comments
FIRE SPRINKLER
Underground piping hydrostatically tested
Underground piping flushed
Interior piping hydrostatically tested
Interior piping inspection
Dry system air tested at 40 psi (24 hours)
Sprinkler final .1_2Z_11 KM
FIRE ALARM
Rough -in inspection
Alarm final
LP -GAS Completed by Contractor
Underground piping inspection /pressure test Test #1
Above ground piping inspection/pressure test Piping pressure test
Tank (container) inspection Time initiated
Test #2
Appliance inspection Piping pressure test
Time initiated
LP -gas final
UNDERGROUND STORAGE TANK (UST) ABANDONMENT
Removal of flammable /combustible liquids
Tank appropriately abandoned
UST abandonment final
PERMIT OTHER (specify)
permit final
GENERAL COMMENTS
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE
2/15/00
psi
psi
1
I
Applicant or Agent vac e_ Q-/✓'
Owner S fe t-±cr C` c) Ga
Owner's Addtss ''a 3 (4 c- �,n�C, u'-� 0
Contractor /Engineer I1b43'V 47El,' F _1 1
Contractor /Engineer's Address u p.A
License /,t.1/1/0 V
d
PROJECT ADDRESS 9 V L'/ Q, C. i v c (J2_
Parcel Number
Project Type Brief Description.
Check all that apply
?New Construction
Addition
Remodel
Repair
Re -roof
Demolition
Sign
Heat System
Other
BUILDING PERMIT APPLICATION Print in ink
For City Use Orly
Date Received
Permit 1\ -12.
Date Approved
CITY OF PORT ANGELES
Attn Building Permit Technician
321 E. Fifth St. Port Angeles WA 98362
(360) 417 -4815 fax (360) 417 -4711
)?Ckesidential Commercial Multi- family Industrial
wall- mounted projecting freestanding awning other
Total sign area sq ft. Maximum allowed sign area sa ft.
Heat pump wood burning stove gas fireplace pellet stove other
Floor Areas Existing (sq. ft.) Proposed (so. ft.)
Basement
1 S1 Floor
2 Floor
3rd Floor
Garage
Carport
Covered Porch
Deck
Shed
Other
Total footprint of structures sq ft. Lot size
Max height of proposed structures
Will a lawn sprinkler system be installed?
Will a fire snnkler system be installed?
ft.
Occupancy group
Occupant load
Construction type
I have read and completed this application and know it to he true and correct
understand that it is my responsibility to determine what permits are required
projects.
Date 2 /.3 t' Print Name 1 i�c 1 L' Qom` Signatu
T Forms /Building Division/Bldg Permit Appl. -2006 Code doc
Phone Z 7S 3
Phone ?c c7 C. `7
'Phone y.y
Expires 81,21/
TOTAL VALUATION /87 "s; o
sq ft. Lot coverage
re
Lot Z 7 Zoning
per sq ft.
of bedrooms
of full baths
of half baths
I am authorized to apply for this permit and
and to obtain permits prior to working on
PREPARED 12/20/10 9 23 05 INSPECTION TICKET PAGE 4
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 12/20/10
ADDRESS 1944 VILLAGE CIR SUBDIV
TENANT NBR STEPHANIE HOLCOMB
CONTRACTOR PHONE
OWNER STEPHANIE HOLCOMB PHONE
PARCEL 06 30 13 5 7 0270 0000
APPL NUMBER 10 00000513 RES NEW SFR
PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
BL1 01 11 /10 /10 JLL BLDG FOUNDATION FOOTING TIME 09 00
11/10/10 AP November 9 2010 4 01 08 PM 1pangrle
BRUCE 912 0079
FOOTINGS
HE REQUESTED THE EARLIEST POSSIBLE MORNING INSPECTION SO
THEY CAN POUR TODAY
November 10 2010 4 36 53 PM jlierly
BL2 01 11/12/10 PB BLDG FOUNDATION STEM WALL TIME 01 00
11/12/10 AP November 12 2010 8 28 33 AM 1pangrle
BRUCE 912 0079
STEMWALL
AFTERNOON
November 12 2010 4 53 01 PM pbarthol
BLFD 01 11/22/10 PB BLDG FOUNDATION DRAINAGE
11/23/10 CA November 19 2010 4 27 28 PM 1pangrle
STAN 461 1834
FOUNDATION DRAINAGE
PLEASE INSPECT AS EARLY AS POSSIBLE
unable to inspect because of snow reschedule inspection
DSD 01 11/22/10 PB BLDG DOWN SPOUT DRAINS
11/23/10 CA November 19 2010 4 27 13 PM 1pangrle
STAN 461 1834
DOWNSPOUT DRAINS
PLEASE INSPECT AS EARLY AS POSSIBLE
unable to inspect because of snow reschedule inspection
BLFD 02 11/30/10 JLL BLDG FOUNDATION DRAINAGE
11/30/10 AP November 30 2010 8 28 24 AM 1pangrle
STAN 461 1834
FOUNDATION DRAINAGE
November 30 2010 4 38 55 PM jlierly
DSD 02 11/30/10 JLL BLDG DOWN SPOUT DRAINS
11/30/10 AP November 30 2010 8 28 09 AM 1pangrle
STAN 461 1834
DOWNSPOUT DRAINS
November 30 2010 4 38 55 PM jlierly
BL3 01 12/15/10 JLL BLDG FRAMING TIME 01 00
12/15/10 DA December 15 2010 8 10 59 AM 1pangrle
BRUCE 912 0079
SUBFLOOR NAILING
AFTERNOON
December 15 2010 4 33 00 PM jlierly
Nail rim joist to mud sill 6 oc around perimeter/j11
BL3 02 12/20/10 JLL BLDG FRAMING TIME 09 00
December 20 2010 9 15 00 AM 1pangrle
BRUCE 912 0079
CONTINUED ONTO NEXT PAGE
PREPARED 12/15/10 8 12 39 INSPECTION TICKET PAGE 1
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 12/15/10
ADDRESS 1944 VILLAGE CIR SUBDIV
TENANT NBR STEPHANIE HOLCOMB
CONTRACTOR PHONE
OWNER STEPHANIE HOLCOMB PHONE
PARCEL 06 30 13 5 7 0270 0000
APPL NUMBER 10 00000513 RES NEW SFR
PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
BL1 01 11 /10 /10 JLL BLDG FOUNDATION FOOTING TIME 09 00
11 /10 /10 AP November 9 2010 4 01 08 PM 1pangrle
BRUCE 912 0079
FOOTINGS
HE REQUESTED THE EARLIEST POSSIBLE MORNING INSPECTION SO
THEY CAN POUR TODAY
November 10 2010 4 36 53 PM jlierly
BL2 01 11/12/10 PB BLDG FOUNDATION STEM WALL TIME 01 00
11/12/10 AP November 12 2010 8 28 33 AM 1pangrle
BRUCE 912 0079
STEMWALL
AFTERNOON
November 12 2010 4 53 01 PM pbarthol
BLFD 01 11/22/10 PB BLDG FOUNDATION DRAINAGE
11/23/10 CA November 19 2010 4 27 28 PM 1pangrle
STAN 461 1834
FOUNDATION DRAINAGE
PLEASE INSPECT AS EARLY AS POSSIBLE
unable to inspect because of snow reschedule inspection
DSD 01 11/22/10 PB BLDG DOWN SPOUT DRAINS
11/23/10 CA November 19 2010 4 27 13 PM 1pangrle
STAN 461 1834
DOWNSPOUT DRAINS
PLEASE INSPECT AS EARLY AS POSSIBLE
unable to inspect because of snow reschedule inspection
BLFD 02 11/30/10 JLL BLDG FOUNDATION DRAINAGE
11/30/10 AP November 30 2010 8 28 24 AM 1pangrle
STAN 461 1834
FOUNDATION DRAINAGE
November 30 2010 4 38 55 PM jlierly
DSD 02 11/30/10 JLL BLDG DOWN SPOUT DRAINS
11/30/10 AP November 30 2010 8 28 09 AM 1pangrle
STAN 461 1834
DOWNSPOUT DRAINS
November 30 2010 4 38 55 PM jlierly
BL3 01 12/15/10 L BLDG FRAMING TIME 01 00
December 15 2010 8 10 59 AM 1pangrle
BRUCE 912 0079
SUBFLOOR NAILING
AFTERNOON
COMMENTS AND NOTES
VZ.
V
Application Number
Application pin number
Property Address
ASSESSOR PARCEL NUMBER
Application type description
Subdivision Name
Property Use
Property Zoning
Application valuation
Application desc
New home
Owner
STEPHANIE HOLCOMB
1334 SAMARA DR
PORT ANGELES
Permit
Additional desc
Permit pin number 178376
Permit Fee 145 50
Issue Date 12/03/10
Expiration Date 6/01/11
Qty
1 00
1 00
Unit Charge
110 3000
35 2000
Fee summary Charged
Permit Fee Total
Plan Check Total
Grand Total
WA 98363
ELECTRICAL NEW RESIDENTIAL
Per
ECH
ECH
145 50
00
145 50
INSPECTION TYPE DATE.
DITCH
SERVICE
ROUGH IN
FINAL
COMMENTS
PERMIT WILL EXPIRE SIX (6) MONTHS FROM LAST INSPECTION
Signature of owner or Electrical Contractor X
ELECTRICAL PERMIT
CITY OF PORT ANGELES
360- 417 -4735
10 00001410
713020
1944 VILLAGE CIR
06 30 13 5 7 0270 0000
ELECTRICAL ONL
RESIDENTIAL HIGH DENSITY
0
145 50
00
145 50
Contractor
OLYMPIC WIRING INC
9601 PROVOST ROAD NW
SILVERDALE WA 98383
(360) 692 0134
Plan Check Fee
Valuation
EL R SQFT FIRST 1300
EL R SQFT ADDITIONAL 500
Paid Credited
00
00
00
RESULTS
12l&Jln
12.211 i .P
Date 12/03/10
00
0
Extension
110 30
35 20
Due
00
00
00
INSPECTOR.
7iNp
Date:
REPORT STATE SALES TAX
on your excise tax form
to the City of Port Angeles
(Location Code 0502)
v
PREPARED 11/30/10 8 29 31 INSPECTION TICKET PAGE 3
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 11/30/10
ADDRESS 1944 VILLAGE CIR SUBDIV
TENANT NBR STEPHANIE HOLCOMB
CONTRACTOR PHONE
OWNER STEPHANIE HOLCOMB PHONE
PARCEL 06 30 13 5 7 0270 0000
APPL NUMBER 10 00000513 RES NEW SFR
PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
BL1 01 11 /10 /10 JLL BLDG FOUNDATION FOOTING TIME 09 00
11/10/10 AP November 9 2010 4 01 08 PM 1pangrle
BRUCE 912 0079
FOOTINGS
HE REQUESTED THE EARLIEST POSSIBLE MORNING INSPECTION SO
THEY CAN POUR TODAY
November 10 2010 4 36 53 PM jlierly
BL2 01 11/12/10 PB BLDG FOUNDATION STEM WALL TIME 01 00
11/12/10 AP November 12 2010 8 28 33 AM 1pangrle
BRUCE 912 0079
STEMWALL
AFTERNOON
November 12 2010 4 53 01 PM pbarthol
BLFD 01 11/22/10 PB BLDG FOUNDATION DRAINAGE
11/23/10 CA November 19 2010 4 27 28 PM 1pangrle
STAN 461 1834
FOUNDATION DRAINAGE
PLEASE INSPECT AS EARLY AS POSSIBLE
unable to inspect because of snow reschedule inspection
DSD 01 11/22/10 PB BLDG DOWN SPOUT DRAINS
11/23/10 CA November 19 2010 4 27 13 PM 1pangrle
STAN 461 1834
DOWNSPOUT DRAINS
PLEASE INSPECT AS EARLY AS POSSIBLE
unable to inspect because of snow reschedule inspection
BLFD 02 11/30/10 JLL BLDG FOUNDATION DRAINAGE
November 30 2010 8 28 24 AM 1pangrle
STAN 461 1834
FOUNDATION DRAINAGE
DSD 02 11/30/10 JLL BLDG DOWN SPOUT DRAINS
November 30 2010 8 28 09 AM 1pangrle
STAN 461 1834
DOWNSPOUT DRAINS
COMMENTS AND NOTES
PREPARED 11/22/10 8 26 38 INSPECTION TICKET PAGE 2
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 11/22/10
ADDRESS 1944 VILLAGE CIR SUBDIV
TENANT NBR STEPHANIE HOLCOMB
CONTRACTOR PHONE
OWNER STEPHANIE HOLCOMB PHONE
PARCEL 06 30 13 5 7 0270 0000
APPL NUMBER 10 00000513 RES NEW SFR
PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
BL1 01 11 /10 /10 JLL BLDG FOUNDATION FOOTING TIME 09 00
11 /10 /10 AP November 9 2010 4 01 08 PM 1pangrle
BRUCE 912 0079
FOOTINGS
HE REQUESTED THE EARLIEST POSSIBLE MORNING INSPECTION SO
THEY CAN POUR TODAY
November 10 2010 4 36 53 PM jlierly
BL2 01 11/12/10 PB BLDG FOUNDATION STEM WALL TIME 01 00
11/12/10 AP November 12 2010 8 28 33 AM 1pangrle
BRUCE 912 0079
STEMWALL
AFTERNOON
November 12 2010 4 53 01 PM pbarthol
BLFD 01 11/22/10 JLL BLDG FOUNDATION DRAINAGE
November 19 2010 4 27 28 PM 1pangrle
I' STAN 461 1834
FOUNDATION DRAINAGE
PLEASE INSPECT AS EARLY AS POSSIBLE
DSD 01 11/22/10 JLL BLDG DOWN SPOUT DRAINS
November 19 2010 4 27 13 PM 1pangrle
STAN 461 1834
DOWNSPOUT DRAINS
PLEASE INSPECT AS EARLY AS POSSIBLE
COMMENTS AND NOTES
0,u/1-6c4.- r& iW sfte4 8gMs r-
PREPARED 11/12/10 9 03 10 INSPECTION TICKET PAGE 5
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 11/12/10
ADDRESS 1944 VILLAGE CIR SUBDIV
TENANT NBR STEPHANIE HOLCOMB
CONTRACTOR PHONE
OWNER STEPHANIE HOLCOMB PHONE
PARCEL 06 30 13 5 7 0270 0000
APPL NUMBER 10 00000513 RES NEW SFR
PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
BL1 01 11 /10 /10 JLL BLDG FOUNDATION FOOTING TIME 09 00
11/10/10 AP November 9 2010 4 01 08 PM 1pangrle
BRUCE 912 0079
FOOTINGS
HE REQUESTED THE EARLIEST POSSIBLE MORNING INSPECTION SO
THEY CAN POUR TODAY
November 10 2010 4 36 53 PM jlierly
BL2 01 11 12/10 JLL BLDG FOUNDATION STEM WALL TIME 01 00
Z1 l
L� November 12 2010 8 28 33 AM 1pangrle
BRUCE 912 0079
STEMWALL
AFTERNOON
COMMENTS AND NOTES
PREPARED 11 /10 /10 8 08 44 INSPECTION TICKET PAGE 9
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 11 /10 /10
ADDRESS 1944 VILLAGE CIR SUBDIV
TENANT NBR STEPHANIE HOLCOMB
CONTRACTOR PHONE
OWNER STEPHANIE HOLCOMB PHONE
PARCEL 06 30 13 5 7 0270 0000
APPL NUMBER 10 00000513 RES NEW SFR
PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
BL1 01 11/10/10
BLDG FOUNDATION FOOTING TIME 09 00
November 9 2010 4 01 08 PM 1pangrle
BRUCE 912 0079
FOOTINGS
HE REQUESTED THE EARLIEST POSSIBLE MORNING INSPECTION SO
THEY CAN POUR TODAY
COMMENTS AND NOTES
eai\r
c
Application Number
Application pin number
Property Address
ASSESSOR PARCEL NUMBER
Tenant nbr name
Application type description
Subdivision Name
Property Use
Property Zoning
Application valuation
Application desc
1 124 SF SFR 376 SF GARAGE 48 SF CVRD PORCH
Owner
STEPHANIE HOLCOMB
1334 SAMARA DR
PORT ANGELES
Permit
Additional desc
Permit pin number
Permit Fee
Issue Date
Expiration Date
T \Policies \1102 15 [10/08]
WA 98363
Qty Unit Charge Per
1 00 55 0000 HR PW INSPECTION
Qty Unit Charge Per
1 00 420 0000 EA PW WATER METER DROP IN
Permit PUBLIC WORKS STORMWATER
Additional desc STORM WATER CONNECTION
Permit pin number 166314
Permit Fee 135 00
CITY OF PORT ANGELES
PUBLIC WORKS UTILITIES
321 EAST 5TH STREET PORT ANGELES, WA 98362
10 00000513
082325
1944 VILLAGE CIR
06 30 13 5 7 0270 0000
STEPHANIE HOLCOMB
RES NEW SFR
RESIDENTIAL HIGH DENSITY
107396
Contractor
OWNER
Date 10/28/10
Structure Information 000 000 1 124 SF SFR 376 SF GAR 48 CVR PORCH
Other struct info TOTAL W LOT COVERAGE 30 90
CONSTRUCTION TYPE VB
FIRE SPRINKLERS REQUIRED YES
NUMBER OF STORIES 1 00
LOT SIZE 5002 00
PROPOSED LOT COVERAGE 1548 00
TOTAL LOT COVERAGE 1548 00
NUMBER OF UNITS 1 00
PUBLIC WORKS INSPECTION
DRIVEWAY INSPECTION
166322
55 00 Plan Check Fee
10/28/10 Valuation
4/26/11
0 0
0
Extension
55 00
Permit PUBLIC WORKS RES WATER SERV
Additional desc 3/4 DROP IN WATER METER
Permit pin number 166298
Permit Fee 420 00 Plan Check Fee 00
Issue Date 10/28/10 Valuation 107396
Expiration Date 4/26/11
Extension
420 00
Plan Check Fee 00
REPORT SALES TAX
on your state excise tax form
to the City of Port Angeles
(Location Code 0502)
Separate Permits are required for electrical work, SEPA, Shoreline ESA, utilities private and public improvements This permit becomes
null and void if work or construction authorized is not commenced within 180 days if construction or work is suspended or abandoned
for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last
inspection I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of
laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construct
/g
Signature of Contractor o horized Agent Date Signature of Owner (if owner is builder) Date
PW UTILITIES (Engineering Division)
WATERLINE METER
SEWER CONNECTION
SANITARY
STORM
SITE DRAINAGE
SITE EROSION CONTROL
PARKING
SIDEWALK
CURB GUTTER
DRIVEWAY APPROACH
BACK -FLAW DEVICE
RESIDENTIAL
ENGINEERING 417 -4831
FIRE 417 -4653
I PLANNING DEPT 417 -4750
BUILDING 417 -4815
T ,Policies \l 102 1 [10/08]
PERMIT INSPECTION RECORD
CALL 417 -4831 FOR UTILITY INSPECTIONS PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER,
INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED 4ND ACCEPTED POST PERMIT IN A CONSPICUOUS LOCATION
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE
INSPECTION TYPE DATE ACCEPTED COMMENTS
YES I NO
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
DATE YES NO COMMERCIAL DATE ACCEPTED
YES I NO
CONSTRUCTION R.W PW/ CONSTRUCTION R.W
PW ENGINEERING
FIRE DEPT
PLANNING DEPT
BUILDING
Application Number 10 00000513
Application pin number 082325
Issue Date 10/28/10 Valuation
Expiration Date 4/26/11
Qty Unit Charge Per
1 00 135 0000 EA SAN SEW STM CON OTHER
Permit
Additional desc
Permit pin number
Permit Fee
Issue Date
Expiration Date
SANITARY SEWER HOOK UP
Qty Unit Charge Per
1 00 150 0000 EA SAN SEWER HOOKUP
CITY OF PORT ANGELES
PUBLIC WORKS UTILITIES
321 EAST 5TH STREET PORT ANGELES, WA 98362
166306
150 00 Plan Check Fee 00
10/28/10 Valuation 107396
4/26/11
Special Notes and Comments
May 25 2010 8 28 21 AM rbecker
The permit did not say if you were installing a lawn
sprinkler system or a fire system If you are installing a
lawn sprinkler or a closed fire system you will need to
install a double check valve assembly If you are installing
a open fire system you will not need to install a backflow
assembly
If you have any question contact Ron Becker at 417 4886 or
E mail me at rbecker @cityofpa us
Address numbers shall be plainly visible from the street
Address numbers shall be a minimum of six inches high and be
of contrasting color from the background
All homes in new subdivisions that are outside of the Fire
Department four minute response area shall be equipped with
residential fire sprinkler systems that comply with the
International Fire Code (IFC) and National Fire Protection
Association (NFPA)
This project will require seperate permit and fire
sprinkler plans for review
Call for cover inspection for all sprinkler installations
May 25 2010 10 49 05 AM sroberds
The proposal will result in a new sfr in the RHD for a total
of 31% lot coverage and 43% site coverage No land use
issues anticipated
Electrical load calculations and electrical permits are
required
All connections to City storm drain facilities require an
Extension
150 00
REPORT SALES TAX
on your state excise tax form
to the City of Port Angeles
(Location Code 0502)
Page 2
Date 10/28/10
107396
Extension
135 00
Separate Permits are required for electrical work, SEPA, Shoreline ESA, utilities private and public improvements This permit becomes
null and void if work or construction authorized is not commenced within 180 days if construction or work is suspended or abandoned
for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last
inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of
laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Signature of Contractor or Authorized Agent Date Signature of Owner (if owner is builder) Date
T \Policies \1 102 15 [10 /08i
CALL 417 -4831 FOR UTILITY INSPECTIONS PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER,
INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE
INSPECTION TYPE DATE ACCEPTED COMMENTS
PW UTILITIES (Engineering Division)
WATERLINE METER
SEWER CONNECTION
SANITARY
STORM
SITE DRAINAGE
SITE EROSION CONTROL
PARKING
SIDEWALK
CURB GUTTER
DRIVEWAY APPROACH
BACK -FLOW DEVICE
T ,Policies \1102 1 [10 /08]
RESIDENTIAL
PERMIT INSPECTION RECORD
YES NO
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
DATE YES NO COMMERCIAL DATE ACCEPTED
YES I NO
CONSTRUCTION R.W PW/ CONSTRUCTION R.W
ENGINEERING 417 -4831 PW ENGINEERING
FIRE 417 -4653 I I I I FIRE DEPT
PLANNING DEPT 417 -4750 I I I I PLANNING DEPT
BUILDING 417 -4815 I I I BUILDING
Application Number
Application pin number
Special Notes and Comments
inspection by Public Works and Utilities Engineering prior
cover Notice will be given 48 hours in advance of
commencing work
Sanitary sewer connection inspection is required by
Public Works prior to back fill of ditch 24 hour advance
notice is required
Construct driveway to City Standards Concrete with exposed
aggregate or other non standard finishes(including colors or
dyes)are not allowed in the City road right of way Broom
finish only An inspection by Public Works Engineering is
required prior to pouring concrete
Other Fees
Fee summary
Permit Fee Total
Plan Check Total
Other Fee Total
Grand Total
T \Policies \1102 15 [10 /08]
CITY OF PORT ANGELES
PUBLIC WORKS UTILITIES
321 EAST 5TH STREET PORT ANGELES, WA 98362
10 00000513
082325
RES UNDERGRND SERVICE FEE
SEWER SYSTEM DELV CHARGE
STATE SURCHARGE
PW WATER SYSTEM USE FEE
Charged Paid Credited
760 00 760 00 00
00 00 00
4734 50 4734 50 00
5494 50 5494 50 00
Page 3
Date 10/28/10
770 00
1980 00
4 50
1980 00
Due
00
00
00
00
REPORT SALES TAX
on your state excise tax form
to the City of Port Angeles
(Location Code 0502)
Separate Permits are required for electrical work, SEPA, Shoreline ESA, utilities private and public improvements This permit becomes
null and void if work or construction authorized is not commenced within 180 days if construction or work is suspended or abandoned
for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last
inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of
laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction
Signature of Contractor or Authorized Agent Date Signature of Owner (if owner is builder) Date
PW UTILITIES (Engineering Division)
WATERLINE METER
SEWER CONNECTION
SANITARY
STORM
SITE DRAINAGE
SITE EROSION CONTROL
PARKING
SIDEWALK
CURB GUTTER
DRIVEWAY APPROACH
BACK -FLOW DEVICE
CONSTRUCTION R.W PW/
ENGINEERING 417 -4831
I FIRE 417 -4653 I
I PLANNING DEPT 417 -4750 I
BUILDING 417 -4815
T \Policies \11021 [10/08]
RESIDENTIAL
PERMIT INSPECTION RECORD
CALL 417 -4831 FOR UTILITY INSPECTIONS PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE IT IS UNLAWFUL TO COVER,
INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED POST PERMIT IN A CONSPICUOUS LOCATION
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE
INSPECTION TYPE DATE ACCEPTED COMMENTS
YES NO
I I
I I
I I
I I
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
DATE YES NO COMMERCIAL DATE ACCEPTED
YES I NO
CONSTRUCTION R.W
PW ENGINEERING
I FIRE DEPT
I PLANNING DEPT
BUILDING
I I I
I I I
I I
I I
Application Number
Application pin number
Property Address
ASSESSOR PARCEL NUMBER
Tenant nbr name
Application type description
Subdivision Name
Property Use
Property Zoning
Application valuation
Application desc
1 124 SF SFR 376 SF GARAGE 48 SF CVRD PORCH
Owner
STEPHANIE HOLCOMB
1334 SAMARA DR
PORT ANGELES
T:FormsBuilding DivisionBuilding Permit
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY ECONOMIC DEVELOPMENT BUILDING DIVISION
321 EAST 5TH STREET PORT ANGELES, WA 98362
3 00 7 2500 EA
1 00 10 6500 EA
8 00 14 8000 EA
WA 98363
Permit
Additional desc
Permit pin number
Permit Fee
Issue Date
Expiration Date
Qty Unit Charge Per
8 00 5 6000 THOU
Permit
Additional desc
Permit pin number 165803
Permit Fee 200 80
Issue Date 10/28/10
Expiration Date 4/26/11
Qty Unit Charge Per
10 00000513
082325
1944 VILLAGE CIR
06 30 13 5 7 0270 0000
STEPHANIE HOLCOMB
RES NEW SFR
RESIDENTIAL HIGH DENSITY
107396
Contractor
OWNER
Structure Information 000 000 1 124 SF SFR 376 SF GAR 48 CVR PORCH
Other struct info TOTAL LOT COVERAGE 30 90
CONSTRUCTION TYPE VB
FIRE SPRINKLERS REQUIRED YES
NUMBER OF STORIES 1 00
LOT SIZE 5002 00
PROPOSED LOT COVERAGE 1548 00
TOTAL LOT COVERAGE 1548 00
NUMBER OF UNITS 1 00
BUILDING PERMIT RESIDENTIAL
1 124 SF SFR 376 SF GARAGE
165795
1065 05
10/28/10 Valuation
4/26/11
BASE FEE
BL -100 001 500K (5 60 PER K)
MECHANICAL PERMIT
Plan Check Fee
Plan Check Fee
BASE FEE
ME VENT FAN (SINGLE DUCT)
ME STOVE /FIREPLACE /MISC APP
ME HEATER(SUSP /WALL /FLOOR MTD)
Date 10/28/10
Date Print Name Signature of Contractor or /tiorized Agent
692 28
107396
Extension
1020 25
44 80
00
Valuation 0
Extension
50 00
21 75
10 65
118 40
REPORT SALES TAX
on your state excise tax form
to the City of Port Angeles
(Location Code 0502)
=0
Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and
void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned fora period of 180 days
after the work has commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have
read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will
be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any
state or local law regulating construction or the performance of construction.
16/9- cdo 13 tie caPtc,1
Signature of Owner (if owner is builder)
FOUNDATION
Footings
Stemwall
Foundation Drainage Downspouts
Piers
Post Holes (Pole Bldgs.)
PLUMBING
Under Floor Slab
Rough -In
Water Line (Meter to Bldg)
Gas Line
Back Flow Water
AIR SEAL.
Walls
Ceiling
FRAMING
Joists Girders Under Floor
Shear Wall Hold Downs
Walls Roof Ceiling
Drywall (Interior Braced Panel Only)
T -Bar
INSULATION:
Slab
Wall Floor Ceiling
MECHANICAL.
Heat Pump Furnace FAU Ducts
Rough -In
Gas Line
Wood Stove Pellet Chimney
Commercial Hood Ducts
BUILDING PERMIT INSPECTION RECORD
PLEASE PROVIDE A MINIMUM 24 -HOUR NOTICE FOR INSPECTIONS
Building Inspections 417 4815 Electrical Inspections 417 4735
Public Works Utilities 417 4831 Backflow Prevention Inspections 417 4886
IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED
POST PERMIT IN CONSPICUOUS LOCATION KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
MANUFACTURED HOMES
Footing Slab
Blocking Hold Downs I
Skirting
PLANNING DEPT Separate Permit #s SEPA.
Parking Lighting I ESA.
Landscaping I SHORELINE.
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/ USE
Inspection Type
Electrical 417 -4735
Construction R.W PW Engineering 417 -4831
Fire 417 -4653
Planning 417 -4750
Building 417 -4815
T Forms /Building Division /Building Permit
FINAL Date Accepted by
FINAL Date Accepted by
Date Accepted By
IngSAM
Application Number 10 00000513
Application pin number 082325
Permit PLUMBING PERMIT
Additional desc
Permit pin number 165811
Permit Fee 142 00 Plan Check Fee
Issue Date 10/28/10 Valuation
Expiration Date 4/26/11
Qty Unit Charge Per Extension
BASE FEE 50 00
9 00 7 0000 EA PL- PLUMBING TRAP 63 00
1 00 7 0000 EA PL -WATER LINE 7 00
1 00 15 0000 EA PL -SEWER LINE 15 00
1 00 7 0000 EA PL -WATER HEATER 7 00
Special Notes and Comments
May 25 2010 8 28 21 AM rbecker
The permit did not say if you were installing a lawn
sprinkler system or a fire system If you are installing a
lawn sprinkler or a closed fire system you will need to
install a double check valve assembly If you are installing
a open fire system you will not need to install a backflow
assembly
If you have any question contact Ron Becker at 417 4886 or
E mail me at rbecker@cityofpa us
Address numbers shall be plainly visible from the street
Address numbers shall be a minimum of six inches high and be
of contrasting color from the background
All homes in new subdivisions that are outside of the Fire
Department four minute response area shall be equipped with
residential fire sprinkler systems that comply with the
International Fire Code (IFC) and National Fire Protection
Association (NFPA)
This project will require seperate permit and fire
sprinkler plans for review
Call for cover inspection for all sprinkler installations
May 25 2010 10 49 05 AM sroberds
The proposal will result in a new sfr in the RHD for a total
of 31% lot coverage and 43% site coverage No land use
issues anticipated
Electrical load calculations and electrical permits are
required
All connections to City storm drain facilities require an
inspection by Public Works and Utilities Engineering prior
cover Notice will be given 48 hours in advance of
Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and
void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days
after the work has commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have
read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will
be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any
state or local law regulating construction or the performance of construction.
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner (if owner is builder)
T:FormsBuilding Division/Building Permit
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY ECONOMIC DEVELOPMENT BUILDING DIVISION
321 EAST 5TH STREET PORT ANGELES WA 98362
Page 2
Date 10/28/10
00
0
REPORT SALES TAX
on your state excise tax form
to the City of Port Angeles
(Location Code 0502)
BUILDING PERMIT INSPECTION RECORD
PLEASE PROVIDE A MINIMUM 24 -HOUR NOTICE FOR INSPECTIONS
Building Inspections 417 -4815 Electrical Inspections 417 -4735
Public Works Utilities 417 -4831 Backflow Prevention Inspections 417 -4886
IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED
POST PERMIT IN CONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION
Footings
Stemwall
Foundation Drainage Downspouts
Piers
Post Holes (Pole Bldgs.)
PLUMBING
Under Floor Slab
Rough -In
Water Line (Meter to Bldg)
Gas Line
Back Flow Water
AIR SEAL.
Walls
Ceiling
FRAMING
Joists Girders Under Floor
Shear Wall Hold Downs
Walls Roof Ceiling
Drywall (Interior Braced Panel Only)
T -Bar
INSULATION.
Slab
Wall Floor Ceiling
MECHANICAL.
Heat Pump Furnace FAU Ducts
Rough -In
Gas Line
Wood Stove Pellet Chimney
Commercial Hood Ducts
MANUFACTURED HOMES
Footing Slab
Blocking Hold Downs
Skirting
PLANNING DEPT Separate Permit #s SEPA.
Parking Lighting I ESA.
Landscaping I SHORELINE.
T.Forms /Building Division /Building Permit
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/ USE
Inspectiion Type
Electrical 417 -4735
Construction R.W PW Engineering 417 -4831
Fire 417 -4653
Planning 417 -4750
Building 417 -4815
FINAL Date Accepted by
FINAL Date Accepted by
Date Accepted By
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY ECONOMIC DEVELOPMENT BUILDING DIVISION
321 EAST 5TH STREET PORT ANGELES, WA 98362
Application Number
Application pin number
10 00000513
082325
Special Notes and Comments
commencing work
Sanitary sewer connection inspection is required by
Public Works prior to back fill of ditch 24 hour advance
notice is required
Construct driveway to City Standards Concrete with exposed
aggregate or other non standard finishes(including colors or
dyes)are not allowed in the City road right of way Broom
finish only An inspection by Public Works Engineering is
required prior to pouring concrete
Other Fees
Fee summary
Permit Fee Total
Plan Check Total
Other Fee Total
Grand Total
T:FormsBuilding Division/Building Permit
RES UNDERGRND SERVICE FEE
SEWER SYSTEM DELV CHARGE
STATE SURCHARGE
PW WATER SYSTEM USE FEE
Charged Paid Credited
1407 85 1407 85 00
692 28 692 28 00
4734 50 4734 50 00
6834 63 6834 63 00
Page 3
Date 10/28/10
770 00
1980 00
4 50
1980 00
Due
00
00
00
00
REPORT SALES TAX
on your state excise tax form
to the City of Port Angeles
(Location Code 0502)
Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and
void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days
after the work has commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have
read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will
be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any
state or local law regulating construction or the performance of construction.
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner (if owner is builder)
IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED
POST PERMIT IN CONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type
FOUNDATION
Footings
Stemwall
Foundation Drainage Downspouts 31
Piers
Post Holes (Pole Bldgs.)
PLUMBING
Under Floor Slab
Rough -In
Water Line (Meter to Bldg)
Gas Line
Back Flow Water
AIR SEAL.
Walls
Ceiling
FRAMING
Joists Girders Under Floor
t Shear Wall ),Hold Downs
Walls Roof Ceiling
Drywall (Interior Braced Panel Only)
T -Bar
INSULATION.
Slab
Wall Floor Ceiling
MECHANICAL.
Heat Pump Furnace FAU Ducts
Rough -In
Gas Line
Wood Stove Pellet Chimney
Commercial Hood Ducts
MANUFACTURED HOMES
Footing Slab
Blocking Hold Downs
Skirting
PLANNING DEPT
Parking Lighting
Landscaping
Separate Permit #s
Electrical
Construction R.W PW Engineering
Fire
Planning
Building
T.Forms /Building Division /Building Permit
BUILDING PERMIT INSPECTION RECORD
PLEASE PROVIDE A MINIMUM 24 -HOUR NOTICE FOR INSPECTIONS
Building Inspections 417 4815 Electrical Inspections 417 4735
Public Works Utilities 417 4831
Date
1 A 10-LO
i1 -17 —JO
11- 10
3-at-It
I7. -OZ -t0
1,(•_ZO
4_ n
Inspection Type
Accepted By Comments
'TLt.
-LL-
417-4735
417 -4831
417 -4653
417 -4750
417 -4815
Backflow Prevention Inspections 417 4886
FINAL Date L cepted by J
y- I4 -It fyrk.nn 0115 Pn
FINAL Date A cccepted by
SEPA.
ESA.
SHORELINE.
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/ USE
Date Accepted By
-21 -1 al.l
�MENip
a s ^a o s as
i OLYMPIC PENINSULA
At -Title Company
`A �N DERE,' PRE INSURANCE ESCROWS
C: NOTE. This form is furnished to give you a statement of actual settlement costs. Amounts paid to and by the settlement agent are shown. Items
marked '(p.o.c.)' were paid outside the closing; they are shown here for informational purposes and are not included in the totals.
D NAME ADDRESS
OF BORROWER.
E. NAME ADDRESS
OF SELLER.
F NAME'& ADDRESS
OF LENDER.
G. PROPERTY LOCATION
H. ETTLEMENT AGENT
P'LACE OF SETTLEMENT
I SETTLEMENT DATE.
FINAL
A. SETTLEMENT STATEMENT (HUD 1)
J. Summary of Borrower's Transaction
100. Gross Amount Due From Borrower
101 Contract sales price
102. Personal property
103 Settlement charges to borrower (line 1400)
104 HACC Prints, Eng., CC, Ins., Taxes, Permits, Cr Rpt
105 USDA Const. Holdback
120. Gross Amount Due From Borrower
200. Amounts Paid By Or In Behalf Of Borrower:
201 Deposit or earnest money
202. Principal amount of new loan(s)
203 Existing loan(s) taken subject to
204
205
206. HTF Loan Funds
207
208.
209
Adjustments For Items Unpaid By Seller
210. City/town taxes' to
211 County taxes to
212. Assessments to
213
214
215
216.
217
218
219
220, Total Paid By /For
Borrower.
300. Cash At Settlement From/To Borrower:
301 Gross amount due from borrower (line 120)
302. Less amount paid by /for borrower (line 220)
303. Cash ❑FROM) (DTO) Borrower
Previous Edition Is Obsolete
Form No 1581
3/86
Stephanie Holcomb
1334 Samara Dr Port Angeles, WA 98363
Housing Authority of the County of Clallam
2603 South Frances St., Port Angeles, WA 98362
USDA Rural Development
1601 E. Front St., Ste B, Port Angeles, WA 98362
1944 Village Circle, Port Angeles, WA 98362
Olympic Peninsula Title Company
319 S. Peabody, Suite A, Port Angeles, WA 98362 (360) 457 -4451
10/25/2010 DISBURSEMENT DATE. 10/25/2010
K. Summary of Seller's Transaction
400. Gross Amount Due To Seller
56.000.00 401 Contract sales price
402. Personal property
2,648.81 403
11,456.19 404
94,155.00 405
Adjustments For Items Paid By Seller In Advance:
106. City /town taxes to ti
107 County taxes to
108. Assessments to
109
110
111
112.
113
114
115
116.
164,260.00
10.00
159,250.00
5,000.00
OMB No. 2502 -0265
B. TYPE OF LOAN
1 FHA 2. FHMA 3 CONV UNINS.
4 VA 5 CONV INS.
6. FILE NUMBER. 7 LOAN NUMBER
95725 -DS
8. MORTGAGE INS. CASE NO.
Adjustments For Items Paid
406. City/town taxes
407 County taxes
408. Assessments
409
410
411
412.
413
414
415
416.
420. Gross Amount Due To Seller.
500. Reductions In Amount Due To Seller:
501 Excess deposit (see instructions)
502. Settlement charges to seller (line 1400)
503 Existing loan(s) taken subject to
504 Payoff 1st Mtg. Ln.
505 Payoff 2nd Mtg. Ln.
506. HACC SHOP 06 -01
507 HACC Revolved Shop Funds
508.
509
By Seller In Advance:
to
to
to
Adjustments For Items Unpaid By Seller.
510. City/town taxes to
511 County taxes to
512. Assessments to
513
514
515
516.
517
518.
519
164,260 00 520. Total Reductions
In Amount Due Seller
600. Cash At Settlement From/To Seller:
164,260.001 601 Gross amount due to seller (line 420)
164,260.001 602. Less reductions in amount due seller (line 520)
0.00 603. Cash (❑TO) ❑FROM) Seller
Page 1 of 3
56.000.00
1
56,000 00'
15,000.00
41,000.00
56,000.00
56,000.001
56,000.00
0 00
SB-4- 3538 -000 -I
HUD -1 (3 -86)
RESPA, HB 4305.2
City of Port Angeles
''Building Division
321 E 5 St.
Port Angeles, WA 98362
RESiuEN I,ML PL#4IV BCEVICVl GUIDELINES
EJ
PLAN REVIEW
Items described here are only a guide to common questions and missed items during plan review and
construction. All codes must be complied with (Please read and follow each item) SPECIAL NOTE Check
item #59 first to see if enaineerina will be needed because of lateral desian issues.
GENERAL.
1 Final grading of the property must be done prior to final inspection even if owner is doing required retaining
walls Occupancy of the home will not be allowed until there are no slopes steeper than 2 units horizontal
to 1 unit vertical or retaining walls are in place or an accepted soils report is submitted to the City If a
soils report was required initially all requirements of the soils report must be accomplished prior to final
inspection including submittal of all field reports
2. Acrylic stucco products have special requirements Verify such with the manufacturer Requirements may
include tongue and groove foam board under finish control joints special backing boards (sometimes OSB
is NOT allowed) self- furring or furred -out wire or fabric lath and sometimes installation by a certified
installer (certified by the manufacturer) Verify any and all requirements of stucco siding or acrylic stucco
products NO INSPECTION OF LATH OR STUCCO IS REQUIRED, BUT WRITTEN CERTIFICATION
BY A MANUFACTURER'S CERTIFIED INSTALLER MUST BE LEFT AT THE JOB SITE UNTIL FINAL
INSPECTION BY THE CITY
Inspection of shear wall nailing roof sheathing to blocking nailing and hold downs must be requested in
addition to standard inspections and before such items are covered up Please specify shear nail roof nail
or hold -down inspection when you request these they may be done simultaneously if ready
4 This plan is approved for OSB or plywood exterior wall sheathing only unless the approved plans at the
time of permit issuance reflect other materials being used Any change to wall sheathing material after
permit issuance must be submitted to the city for review prior to installation An additional plan review fee
will be assessed
5. "Tyvek" or equal approved weather resistive barrier (15# felt is OK) required on the exterior side of all
walls regardless of the type of siding used This includes garage walls gable portion of end walls and
cripple walls (at stepped foundation conditions) Apply over exterior sheathing or over studs in single -wall
construction T 1 -11 or similar panel siding must have 'Tyvek' or equal over the. studs.
6 Exterior windows and doors shall be flashed with approved materials and caulking Caulked trim material
over the window or door flange is not an acceptable method
7 Overall dimensions of house plan must match site plan dimensions Verify any special requirements for
buildings located close to property lines R302
1 Building /Handouts /Residential Plan Pe\Pew Gui,elines (Rev 03- 18 -09)
Page 1 of 8
LIFE SAFETY MISC ITEMS
8 Sleeping rooms must have an egr window with 5 7 s f net clear opening 24" min height 20" min
width 44" maximum from floor to window sill Windows must meet all 4 dimensions R310 1
9 Safety or tempered glass shall be used in windows that are (R308 4)
Adjacent to a door (24 arc of either edge of the door in a closed position)
That are closer than 18" to floor (AND individual .pane is more than 9 s f 'top edge more than 36" a.f f
and walking surface within 36' horizontally of the window in question)
Walls enclosing a tub or shower (AND within 60" of the drain or within 60" of walking. surface) R308 4
Adjacent to stairways landings and ramps within 36" horizontally of a walking surface (AND less than
60' a.f f of the walking surface)
Adjacent to stairways within 60' of the bottom tread of the stair in any direction (AND less than 60"
aff)
10 Under -stair areas that are enclosed and accessible must be sheetrocked 1/2" GWB on walls and
underside of the stairway R311 2 2
11 Stairways shall have 10' min tread and 7 3/4" max. rise R311 5
12. Provide 36" high guards (with 4" max. spacing on rails) at porches balconies and raised floor surfaces
more than 30' above adjacent ground or floor R312 1
13 Smoke detectors required at all bedrooms hallway or room adjacent to bedrooms and at any ceilings that
are more than 24" above adjacent ceiling All smoke detectors interconnected and hardwired with battery
back -up R313 1
14 Garage /house separation wall is 1/2" GWB door must be 20 min rated or 1. 3/8" solid -core If living space
above use 5/8" GWB Type 'X" at the ceiling AND 1/2' GWB at walls that support the floor above Ducts in
garage must be 26 -gage sheet steel and have no openings in the garage R309
15 Exterior stairways must have a light located near the top landing of the stairway switched from inside (or
have motion- activation device) R303 6
16 Minimum room areas must be provided (120 s f min in at least one room 70 s f min all other habitable
rooms 7 foot min dimension in all habitable rooms) R304 1
17 Minimum ceiling heights must be provided (7 foot min with some exceptions) R305 1
FOOTINGS, FOUNDATIONS, AND CRAWL SPACES
18 All footings including exterior isolated pad footings must have a 24" (min) depth from the bottom of the
footing to finished grade R403 1 4 1
19 All footings shall be supported on undisturbed natural soils or engineered fill., Any placement of fill material
that will support a structure will require a geotechnical investigation and report submitted to the City prior to
placement of footings R401 2 R403 1
20 Lots shall be graded to drain surface water away from foundations The grade shall fall 6.' in the first TEN
feet around the perimeter of the structure R401 3
21 Top surface of footings shall be level Bottom surface of footings shall not have a slope that exceeds (1)
unit vertical in (10) units horizontal Any necessary stepping of the foundation must be approved during
plan review or prior to installation of the foundation R403 1 5
T Building /Handouts /Reside, tel Plan Review Guidelines (Rev 03- 18 -09)
Page 2 of 8
22. Wood sill plates of all exterior walls interior bearing walls (slab -on- grade) and interior shear walls (slab -on-
grade) must be anchored to foundation or slab with X 10' J -bolts with a 2' X 2" X 3/16' plate washer
Anchor bolts to be placed a maximum of 12' and no closer than 3 1/2 from the ends of the sill plate Each
piece of sill plate must have a minimum of (2) anchor bolts Anchor bolts shall be spaced no further than 6
feet apart. (Special spacing and sizing conditions may apply at alternate braced wall panels) R403 1 6
23 6' clearance required from finish grade to foundation mudsill plate R319
24 3 1/2' (min thickness for all concrete slabs -on -grade R506 1
25. Footing and foundation wall SIZES for two pour system
(Foundation walls NOT over 5 feet in height)
Footing supporting single story 12" wide X 6' thick.
Foundation wall supporting single story- 6' thick
Footing supporting two stories- 15' wide X 7" thick.
Foundation wall supporting two stories- 8" thick
Foundations that support more than two stories require an engineered design
26. Footing and fnd REINFORCEMENT for two pour system fnd walls NOT over 5 feet in height)
(Footings supporting single or two stories)
One continuous #4 horizontal rebar placed at center of footing with 3" (min) clearance from dirt.
(Foundation walls not over 5 feet in height)
One continuous #4 horizontal rebar placed within the top 12" of the wall
#4 vertical rebar placed at 48 inches o c. max (wet set ok) with a 6 -inch 90- degree hook. A
minimum of (2) vertical bars to be placed at front garage wall returns
27 Monolithically poured foundation systems
Bottom of footing shall be 12" wide (min) and extend to 24" below finished grade minimum
Footing shall have either one #5 continuous horizontal rebar placed at center and 8" above bottom of
footing or (2) #4 continuous horizontal rebar placed at center and in the middle third of the footing
measuring vertically
3 1/2" minimum slab thickness
When a monolithic system is used to support heated spaces an R 10 insulation board must be
installed on the outside of the foundation extending from bottom of footing to top of slab Exposed foam
insulation above grade must be protected from damage and sun with approved materials The material
used must extend a minimum of 12" below grade
28 Basement Walls (up to 9 feet) or Stem Walls (over 5 feet) or STEPPED FOUNDATIONS There are
special restrictions for this type of foundation wall under the new code In plan view the length of this type
of wall cannot exceed 35 feet. For stepped foundations this wall cannot exceed 7 feet high otherwise the
floor joists must connect DIRECTLY to the wall (for bracing the foundation wall) WET- SETTING IS NOT
allowed for the alternating hooks into the footing There are special blocking requirements if any of these
conditions cannot be met (note on the plans!) See R404 1
29 Under -floor pier pads supporting uniform load of wood framed floors shall be 18 'x 18" x 8" (min) Point
loads from other than floor girders will require larger footings sized according to the concentrated load
R403 1 1
30 Beams and /or girders in crawl space must meet span requirements for the loads imposed (from floor joists
and from any point loads) R501 2
T Building /Handouts /Residential Ran Review Guidelines (Rev 03- 18 -09)
Page 3 of 8
31 Access shall be provided to all under -floor spaces Access openings through the floor shall be a minimum
of 18' x 24 Openings through a perimeter wall shall be .a minimum of 16" x 24 R408 3
32. Under -floor spaces shall be ventilated by openings providing one (1) square foot of vent area per 150
square feet of crawl space area One such ventilating opening shall be within 3 feet of each corner of the
building R408 2
33 A ground cover of 6 mil black polyethylene or approved equal shall be laid over the ground within crawl
spaces. The,ground cover shall be overlapped 12" and extend to the foundation wall WSEC 502 1 6 7
34 The under -floor grade shall be cleaned of all vegetation and organic material All wood forms and
construction debris shall be removed prior to final inspection R408
35 Thickened -slab footings must be 12" min total depth (top of conc slab to bottom of footing 12" total)
(Revised from .IRC)
36 Foundation cripple walls shall be framed of studs not less in size than the studding above Cripple walls
with a height less than 14 inches shall be sheathed on one side with a wood structural sheathing or shall
be ,of solid blocking Cripple walls count as an additional "story' for lateral purposes R602 9
FLOOR FRAMING
37 18' (min) clearance beneath all floor joists and 12" (min) clearance beneath floor girders (beams) in crawl
spaces R308
38 Span of all joists (including 2nd level joists) must meet minimum live load of 40 psf (general living areas) or
30 psf (sleeping rooms) together with dead load of materials used R301 5 and Table R301 5
39 Span of beams for 2nd level or other supporting elements must meet minimum live and dead load
requirements R301 5
40 Wood posts in the crawl space shall have a connection to the concrete pier and a moisture barrier between
the post and footing (or use pressure- treated posts) R319 R407
41 Solid -sawn floor joists shall be blocked at all bearing points Engineered floor joists shall be installed per
manufacturer's specifications R502.7
42. Cutting drilling and notching of floor joists shall not exceed the limitations in Figure R502 8
43 Cutting drilling and notching of engineered I- joists shall be in accordance with the manufacturer's
specifications R502 8 2
44 All concentrated point loads originating from roof or floor load shall be transferred to bearing footings or
foundation walls Continuous support shall be provided by members that are equal in cross- sectional area
to the area of the load imposed and shall not be reduced in size at any point.
45 Wood members supported in concrete or masonry pockets shall have a 1 /2 inch air space provided at tops,
sides and ends of the member
46 All foundation plates sills and sleepers bearing on a concrete foundation or slab that is in direct contact
with the ground shall be pressure treated All wood framing members that rest on concrete foundations
and are within 8" of exposed ground shall be pressure treated R319
T Building /Handouts /Residential Plan Review Guidelines (Rev n3-18-09)
Page 4 of 8
47 Sawn lumber floor joists shall have 1W (min) bearing and shall lap 3 min at intermediate girders
Engineered Hoists shall have 1 3/4 (min) bearing (or per manufacturer's specifications)
48 Floor joists that are parallel to bearing partitions shall be doubled Some heavier load cases will require
girder beams or .pony walls Bearing partitions perpendicular to floor joists shall not be offset from the
supporting girder more than the depth of the joists unless the floor joists are of sufficient size to carry the
load R502 4
49 Floor cantilever spans shall not exceed the depth of the nominal floor joists Floor cantilevers constructed
in accordance with Table R502.3 3 (1) shall be permitted when supporting a light framed bearing wall and
roof only R502 3 3
50 Block in between floor joists beneath all interior braced walls (for walls perpendicular to joists) or align floor
joist with interior braced wall (see item #63 -T)
WALL FRAMING
51 Wall studs taller than 10 feet shall have a stud height analysis by a professional engineer or architect.
Table R602 3.5
52. Non -load bearing stud heights shall be in accordance with Table R602.3 (5)
53 Studs shall be a minimum #3 grade standard grade or stud grade lumber R602.2
54 Where joists trusses or rafters are spaced more than 16" o c. and the bearing studs below are spaced at
24" o c. such members shall bear within 5' of the studs below unless the top plates are double 2x6 or a
third plate is added R602.3 3
55 Headers over windows and doors must meet minimum requirements for spans and imposed loads verify
point loads over openings (from trusses or other conditions) and size headers accordingly Headers must
be noted with size type and grade of lumber being used
GENERAL NOTE STATING ALL HEADERS SHALL BE. is acceptable
56 Interior bearing walls must have headers over openings and must be supported to a foundation
57 Top plate splices shall be offset a minimum of 24 inches R602 3 2
58. Fire blocking required at dropped ceilings soffits coved ceiling areas and every ten feet horizontally and
vertically at framed walls R602 8
59 Port Angeles is in Seismic Zone D1 Wind zone of 100 MPH Category C (within 1500 ft from shore line is
Category D) per the 2006 IRC When a house is considered IRREGULAR by any ONE the definitions
below the code will NOT allow prescriptive bracing for Seismic Zone C and the entire house must have a
lateral analysis and design by a licensed engineer (R301 2 2 2 2) Per that section of the code NO MIXING
OF PRESCRIPTIVE AND ENGINEERED LATERAL SYSTEMS IS ALLOWED UNDER THIS NEW 2006
IRC
The following are items that constitute an IRREGULAR BUILDING per the 2006 IRC
A. Exterior braced wall lines must be in one plane vertically from foundation to the uppermost story
(basically the upper floor must match the lower floor footprint) The most common area where
problems like this occur is in a garage with a second floor over it. To qualify for prescriptive bracing
the second floor joists must extend to the exterior walls of the garage If this does NOT occur then
your proposed house is IRREGULAR If the joists do extend to the exterior \A/ails of the garage then
the setback of the second floor walls cannot be more than four (4) feet setback from the garage walls
T Building /Handouts /Residential Plan Review Guidelines (Rev 03- 18 -09)
Page 5 of 8
(see p 44 of the 2006 IRC) Rooms created by roof trusses are OK under this provision (such as
bonus rooms over garages formed by the trusses /rafters)
B The perimeter of all floor diaphragms and all roof diaphragms must be supported on WALLS below If
you have beams holding up any part of the perimeter of a floor or a roof then your proposed house is
IRREGULAR The most common place you will find this problem is at large covered porches and
patios where the roof is supported only by post and beams Such covered porches and patios also
make the building IRREGULAR Related to this are areas of discontinuous diaphragms especially
changes in plate line heights which also are considered as separate roofs and therefore make the
building IRREGULAR
C In any elevation of the exterior the braced walls from an upper level wall must NOT occur over a
window or door In general this means that the windows of the upper story must align with the
windows of the lower story There are some exceptions based on up- sizing the header in the window
below (see 2006 IRC p 44 for details)
D When an opening in a floor or roof (such as a balcony overlook area or a courtyard area) exceeds the
lesser of 12 feet or 50% of the least dimension then your proposed house is IRREGULAR
E. When portions of a floor level are vertically offset (such as =a sunken room) then your proposed house
is IRREGULAR This does not apply to a slab -on- grade floor
F When braced wall lines do not occur in two perpendicular directions (such as portions of the house or
garage at an angle to the rest of the building) then your proposed house. is IRREGULAR
G If you have any portion of the above -grade walls that use masonry or concrete construction then your
proposed house is IRREGULAR Stepped foundations that create a daylight basement situation are
OK under this provision and do not make an irregular structure
60 THIS APPLIES TO ALL LATERAL BRACING (ITEMS 61 THRU 65) Add up all lengths of braced panels
(4 foot braced panels 2 -8' alt. braced panels and 24 or 16' portal frames COUNT as 48' of length each
portal frame counts as a total of 48' of bracing length —not 2 times 48 along the wall in question The
total length of braced walls must be at least 16% of the entire wall length AND the panels must occur at
least every 25 feet along the wall For 1 story of 2- story house 30% of the entire wall length must be
braced walls Check this for all braced wall lines including INTERIOR WALLS and including the front wall
of a garage if it is not part of another braced wall line (i e the garage sticks out in front of the house more
than 4 feet) See also #65 T below for areas where MORE than 35 feet between wall lines is needed
61 Garage lateral bracing systems with no 2 floor above
H Portal Frame for Garages (16' side panels 8 foot max. high walls 20' side panels 10 foot max.
high walls)
I Alternate Braced Walls— single -story condition (2' -8" min width X 10 foot max. height) sheathed on
one side (interior or exterior OK) with min 3/8' OSB or plywood and nailed with 8d common or galv
box nails and blocked at all edges Two (2) anchor bolts in sill plate two (2) hold -down devices
furthest studs (1800 pound capacity hold downs)
J Alternate Braced Walls —first floor of two -story condition (2' -8" min width X 10 foot max. height)
sheathed on BOTH interior and exterior sides of wall with min 3/8" OSB or plywood and nailed with 8d
common or galv box nails and blocked at all edges Two (2) anchor bolts in sill plate two (2) hold
down devices furthest studs (3000 pound capacity hold- downs) There are some provisions for plate
lines up to 12 feet high see Table R602 10 6 (basically a wider wall 3 -6' min length for 12 feet high)
K. Front Garage Panels —no hold -downs required
L. The exterior braced wall lines in a detached or attached garage cannot be more than 35 feet apart in
either direction or interior braced walls must be provided
62. 1 Floor Conditions Four (4) foot solid walls at all corners and at every 25 feet along any braced wall
line OR use one of the methods below
M Portal Frame for a House (slab -on -grade floors ONLY) 16" mir width for one-story structures 24 min
width for first floor of 2 story
T Building /I idouts /Residential Plan Review Guidelines (Rev 03 18 -09)
Page 6 of 8
N Alternate Braced Walls— single -story condition (2 -8' min width X 10 foot max height) sheathed on
one side (interior or exterior OK) with min 3/8" OSB or plywood and nailed with 8d common or gals
box nails and blocked at all edges Two (2) anchor bolts in sill plate two (2) hold -down devices
furthest studs (1800 pound capacity hold- downs)
0 Alternate Braced Walls —first floor of two -story condition (2' -8" min. width X 10 foot max height)
sheathed on BOTH interior and exterior sides of wall with min 3/8" OSB or plywood and nailed with 8d
common or galv box nails and blocked at all edges Two (2) anchor bolts in sill plate two (2) hold
down devices furthest studs (3000 pound capacity hold- downs) There are some provisions for plate
lines up to 12 feet high see Table R602 10 6 (basically a wider wall 3 =6' min length for 12 feet high)
P "Simpson" Brand StrongWalls —this method is still available following all the manufacturer's
specifications for connections
Q. Entire House Sheathed with OSB or Plywood —this method allows smaller side panels than 4 feet in
accordance with Table R602 10 5 CHECK THE OPENING HEIGHTS ADJACENT TO THESE
PANELS!
63. 1st Floor Conditions Braced wall (any of the methods listed above) must start at no more than 12.5_ feet
away from the corner of the braced wall lines and then at every 25 feet (min) along the wall line
64 2 Floor Conditions Braced walls (either of the methods listed below) must be within 12.5 feet of the
corner of the wall line in question
R. Standard four (4) foot panels on 2 levels can start at no more than 12.5 feet away from the corner
S Entire House Sheathed with OSB or Plywood —this method allows smaller side panels than 4 feet in
accordance with Table R602.10 5 CHECK THE OPENING HEIGHTS ADJACENT TO THESE
PANELS!
65. Exterior braced wall lines (or together with some interior wall lines) cannot be more than 35 feet apart.
T Certain areas can be up to 50 feet apart between wall lines IF there is additional bracing along the
exterior wall in question (50/35 1 43 more bracing than normally required or in other words 23% of
the total wall in bracing for 1 -story wall 43% of the total wall in bracing for 1 story of a 2 -story house)
R602 10 1 1 Exception 1 and 2
U Interior Braced Walls can be used when exterior walls are more than 25 feet apart. Interior Braced
Walls are minimum 1/2' GWB both sides of wall for a minimum length of 48' use 5d nails or screws at
7' o c Sole plate of wall must be attached to thickened slab footing (see item #22 above) with 1/2
anchor bolt 6' -0" o c. or solid blocking (walls perpendicular to joists) or LINE UP JOIST with braced
wall (walls parallel to joists)
66 The roof sheathing MUST nail into SOLID blocking and the block must connect to the double top plate
either with clips or toe nailed (for blocks that are top beveled) with 8d 6' o c For ventilation use not
more than two (2) 2' diameter holes BLOCKING MUST OCCUR AROUND ENTIRE PERIMETER OF
ALL ROOFS Table R602 3 (1) This applies to all houses both engineered AND prescriptive bracing
ROOF ATTIC
67 Truss drawings must show reactions of all girder trusses point loads onto headers must have headers
sized accordingly point loads over 5000 lbs onto double -top plates must be checked for bearing capacity
Use "Simpson brand TBE4 or TBE6 as needed to spread the load
68 Truss bottom chord live load must be minimum of 10PSF (see Table R301 5) Trusses must be sized for
the roof coverings specified on the plans (concrete tile etc and roof structure must be able to hold up the
roof (beams headers etc sized for roof loads) R802 10 2
69 Ice Shield is required for roofs up to 6 12 (.6 12 and over DO NOT require ice shield) R905 2 7 1
T Building /Handouts /Residential P n Review C sidelines (Rev 03- 18 -09)
Page 7 of 8
70 Attic ventilation must be provided at 1/150 of the attic area or 1/300 of the attic area if 50% of the venting
can be 3 feet above the eave venting (roof jack vents are 49 sq in /vent, ridge vents at 12 sq in. /foot)
R806 1
71 Attic mechanical equipment, need light and switch near opening and electric outlet. Access opening to
such mechanical equipment must be no further than 20 feet from equipment with 22" wide (min) walkway
from access opening to the equipment.
72. Attic access required 22' X 30" min and shall be in hallway or other readily accessible location R807 1
MECHANICAL.
73 Appliances located in a garage. or carport shall be protected from damage from vehicles M1307 3 1
74 Gas appliances located in a garage shall be raised 18' min above finish floor G2408 2 (305 3)
75 Ductwork that extends below grade (such as in the garage floor) shall be encased in 2" min concrete on all
sides and bottom in addition to the R 10 insulation foam board 603 8 IMC
76 Dryer exhaust ducts shall not exceed 25 feet in length The maximum length of the duct shah be reduced
2 5 feet for each 45- degree bend and 5 feet for each 90- degree bend Longer lengths in accordance with
the manufacturer's listing will be allowed Screws shall not be used to connect any dryer duct materials
M1501 3
77 Flex duct connections to sheet metal transition ducts shall have the inner sleeve taped with approved
materials prior to securing the flex duct with a zip tie or similar fastener 304 IMC
78 Flex duct shall be supported every 4 feet and have no sag that exceeds 1 /z per foot.
79 All exhaust fan ducts shall be connected to the fan housing and termination fittings with a minimum of 3
sheet metal screws and be sealed with approved tape or mastic.
8 0 Exhaust fans required 50 cfm in bathrooms 100 cfm in kitchen 50 cfm min in laundry room and one fan
sized for whole -house ventilation 302 2.2 WSVIAQ
81 Fuel- burning equipment shall not be installed in a closet, bathroom or a room readily usable as a bedroom
82. Water heaters must be secured to structure with straps around tank at 1/3 points to resist lateral
displacement. M1307 2
PLUMBING
83 Cleanouts shall be installed on all sinks and at the upper end of all building drains including any horizontal
drain branches greater than 5 feet in length from the main line A cleanout shall also be installed on the
exterior of the house within 24 inches of the foundation wall level with final grade and shall have a
threaded .type cap installed
84 30" min width for toilet and 24" clear space in front of toilet (UPC)
85. Water heaters pressure relief and the required drain pan shall have a drain that is 3/ JD copper or cpvc
material NO coil material shall be allowed per code and no reduction in the pipe shall reduce the ID of the
material less than 1/4 Pex type is a coil material and is not allowed for this application
T Building /Hai louts /Residential Plan Review Guideii, (Rev 03- 18 -09)
Page 8 of 8
,*oIM\ Kr dallam C ovh' W- ebsi+e- 5/ I Io� t'1ou ;gin )4u-Fhortfiy ,260 3$, Prk 95
BUILDING PER -MI APPLICATION Print in Ink 6
CITY OF PORT ANGELES
Attn Building Permit Technician
321 E. Fifth St. Port Angeles WA 98362
(360) 417 -4815 fax (360) 417 -4711
Applicant 5 4- e- 9 1 1Ck.. i t c.o„„ 10
4- Property Owner S}- �1,� t k ,,,,.1
Property Owner's Address c"
Contractor Ociov.ec f
Contractor's Address
License
PROJECT ADDRESS (q y y U tt
Parcel Number G (S 3o r3 5 o Z'7
Project Type 8 Brief Description. Residential
Check all that apply
"$New Construction 5k
Addition
Floor Areas
Basement
1 Floor
2 Floor
3 Floor
Garage
Carport
Covered Porch
Deck
Shed
Other
7 cu'e (o(
T Forms /Building Division /Building permit application
Existing (sq. ft.) Proposed (sq. ft.)
yg
r( I 8
Expires
Total footprint of structures t 5 9 5 sq ft. T Lot size 5C Z_,
Site Coverage the amount of impervious surface on a parcel including structures
and other impervious surfaces (see PAMC 17 94 135 for exemptions)
Max. height of proposed structures I J ft. Occupancy group
Will a lawn sprinkler system be installed? Occupant load
Will a fire sprinkler system be installed? Construction type
I have read and completed this application and know it to be true and correct. l am authori
that it is my responsibility to determine what permits are required, and to obtain permits pr,
Date s)1d1 10 Print Name 1 ,2 -O4 �j �t Signature
For City Use Only
Date Received 5-1 7,-1 0
ermit i O —5
ate Approved Ib
o e 7 "7
(2.4: Ph 9
F 10.k Ft X63
Phone
E -mail
Lot
Phone 9 [7 00'7 q,
Zoning pcp_p
Commercial Industrial
Multi-family 9
r'eg W cr g Q e_ 2'�'�0.�
1
Remodel
Repair
Demolition
Re -roof j louse )4..garage other tear off re -roof lay ove, one layer
Heat System Heat pump wood- burning stove gas fireplace pellet stove other
Other W &U ine44eir -S
per sq ft
-3® i 1
v4
TOTAL VALUATION IO7 T 6 -1j.22—
sq ft. Lot coverage 30+
paved driveways sidewalks patios
Site coverage I 13.j%
of bedrooms 3
of full baths Z.,,
of half baths
ply for this pe
g on projects
understand
0
1
0
\\\/\L' 4\r
0:3\
5'
C3L4°
Fi4- VI`s
0 210
9wvoscli_ta L1.---A610
go
CITY CIOVERN NT Site Information.
Lot: Z 7 Permit
Address I y L} L `ka C<<L1-_ Notes
City.
State 04 Zip 9 X3 �Z
Contact. `e. cba .ems ru, c 4e_
Phone 1 -11/ 1 `3 117_ 0 0 1
Phone 2
FAX
Table 6 -1
PRESCRIPTIVE REQUIREMENTS FOR GROUP R OCCUPANCY
CLIMATE ZONE 1
(Unlimited Glazing Option Only)
W ll W.11
Glazing Glazing, =U Factor. Door Wall a a,
'Vaulted Interior Exterior 1 'Slab on
AboVe
Option ArFloorOf :Ceiling .Ceilin
Vertical Overhead Factor g Grade' Below. 'below Floor Concrete
Grade.: Grade
Unlimited
Group R 3
IV and R -4 0.35 0 58 0.20 R 38 R 30 R 21 R 21 R 10 R 30 R 10
Occupancies
Only
This Project complies with the following-
The project is a single family residence or duplex.
The project is a wood frame OR all of the insulation is interior or exterior of the framing.
Al All building components meet the requirements listed above
The project will meet all other provisions of the WSEC and VIAQ
The Project will take advantage of the following exceptions to the prescriptive option.
602.6 Exception 2. One unlabeled or untested exterior swinging door 24 sq ft. or less, may be
installed per unit for ornamental, security or archttectura purposes.
Location of the door taking this exception *Tot, eA &o r
602.6 Exception 2. If a door is mostly glass, it should meet the requirement of the vertical
glazing U- factor listed above
Location of the door(s) taking exception
Type of Heat Source: e- C v Wet n
T /Building Division /Prescriptive Approach Simple Form
PRESCRIPTIVE APPROACH SIMPLE FORM
For the Washington State Energy Code (2006 Edition)
Climate Zone 1
Building Department Use Only
l!)RAh bA1
Please complete and return to Public Works Utilities Department
Applicant Information
Permanent service.
Name and address of party
responsible for permanent
service billing?
Contact Information
Site contact:
Contractor
Electrician
Excavator'
Rroject`;Type
Single- family residence
Commercial
Overhead service
Underground service
Project ;Information
Name S `T'e- 4� 41C" t.Gla.
Street: 4 :1 L i T t i `lca 4 --e CT- 7,ra
City I State I ZIP f W& Q 'a_
Daytime Phone
(if other ,pn above j y'3
oqe_
Name uk tee_ 9 ('Z. Oo 9 Title
Daytime Phone
Name Fl- "C Company'
Daytime Phone Z' 1 ‘3)
Name
Daytime Phone
I Name
I Daytime Phone
Existing
Company
Company
Home Phone
(tl1q'ew
Multi-family residence of units
Subdivision of lots
General service
Other
Description of work
Electrical transformer serving property is on a pole on the ground
Street address lot number
Nearest cross street:
Desired connection date
Total square footage
Voltage
Check all that apply
No Load Change
Supporting Documentation
Applicant's Signature
MAIL OR DELIVER COMPL
FAX TO 360- 417 -4711
Information form.xls
hd \FJdf 5 II;HT \FNGR\tIonyindls\Inror r
A/C ton)
21 Dryer
Water Heater
liUrl If rrr
Electrical Information Form
Public Works Utilities Department (360) 417 -4700
City Electrical Inspector (360) 417 -4735
�Qw• {�u r 5i
sT 9 o 3
1 24 sq ft. Main disconnect size 7...c:3 amps
71120/240 1ph 0120/208 3ph 0277/480 3ph
❑120/240 3ph 0480 3W 3ph Other
Standard residential loads (Lighting refrigerator dishwasher washer)
-Range /Oven Hot Tub
�kieating Pumps Hp)
Elevator Hp) Other
Please provide a copy of the following
*Detailed plot plan (dwg or dxf format mandatory for subdivisions)
*Electrical one -line drawing showing the service entrance panel and location
*Connected load data.
Size and locked rotor mps f all motors ov 50
Date
D FORM TO 321 E 5TH STREET PORT ANGELES WA 98362
WS
WF
r«. ,S(( ft C?
I
(1)
0
(-9
I C-271
100A c/o
2
O 2
I
7
J-35
3F SECT Cm,
6 W/3-LBC4
19
1013
---493Vb-
4 17 19
1 1 -201
g
1
13
0 -1
12
C)
91 1A 3 -17
II X
21 I
3 22
22
350 TPX
0
23
24
Village Cir
25
26
0
0
4"eVe1Ftitiii-by
o
0 sdIA
‘ro
11
1/0 /-■LCN 2"PVC
27 '0.0211 A
A 2006 29
7 1 3 5 v 0 J
3
6 3
2p14 t7)
i Q 102
t .1" J
1.13
Clallam County Assessor Treasurer Property Details 66759 HOUSING AUTHORIT Page 1 of 3
Clallam County Assessor Treasurer
Property Search Results 66759 HOUSING AUTHORITY OF CLALLAM for Year 2010 2011
Property
Account
Property ID
66759
Geographic ID 0630135702700000
Type Real
Tax Area. 0010 PA 121 PORT ST CNTY H2 L Land Use Code 97
Open Space: N DFL N
Historic Property N Remodel Property' N
Multi Family Redevelopment: N
Location N O l
Address. 1944 VILLAGE CIR Mapsco
PORT ANGELES WA G `1 ^P/ e/
Neighborhood Exempt All Exmpt Reference Map ID
Neighborhood CD 50110030
Owner
Name HOUSING AUTHORITY OF CLALLAM Owner ID ro 31369
Mailing Address: 2603 S FRANCIS ST Ownership 100 0000000000%
PORT ANGELES WA 98362 -6710
I Taxes and Assessments Due
Property Tax Information as of 05/20/2010
Amount Due if Paid on El_
I Statement
Year ID Taxing Jurisdiction
2010 48792 ST SCH STATE SCHOOL
Legal Description
Agent Code
Exemptions: EX
PENINSULA VILLAGE V15
P6 LOT 27 SURVEY V68
P69
First a Second
Half Half
Base 3 Base i Base Amount
Due Due Penalty I Interest Paid Due
$0 00 $0 00 $0 00 $0 00 $0 00 $0 00
1 2010 48792 CC-GEN COUNTY $0 00 $0 00 $0 00 $0 00 $0 00 $0 00
2010 48792 PORT PORT $0 00 $0 00 $0 00 $0 00_$0 00 $0 00
1T0 PORT ANG PORT ANGELES_ $0 00 $0 00 $0 00 $0 00 $0 00 $0 00
12010 48792 SD #121 SCHOOL DISTRICT #121 $000 $000 $000 $0 00 $0 00 $0 00
2010 48792 NTH OLY_LIBNORTH OLYMPIC LIBRARY
$0 $0 00 $0 00 $0 00 $0 00 $0 00
2010 48792 HOSP #2 HOSPITAL #2 $0 00 $0 00 $0 00 $0 00 $0 00 $0 00
2010 48792 WSMET PK DIST WILLIAM SHORE MET PARK DIST $0 00 $0 00 $0 00 $0 00 $0 00 $0 00
1 2010 48792 WEED CONTROL WEED CONTROL $1 63 mm $0 00_, $0 00 $0 00 $1 63 $0 00
i 2010 48792 TOTAL. $0.00$0.00 $0.00 $1.63 $0.00
2009 667592008 STSCH_ STATE SCHOOL $0_00 $0 00 $0 00 $0 00 $0 00 $0 00
1 2009 667592008 CC -_GEN COUNTY $0 $0 00 $0 00 $0 00 $0 00 $0 00
2009 667592008 PORT PORT $0 00 $0 00 $0,00 $0 00 $0 00_ $0 00
2009 667592008 PORT ANG PORT ANGELES $0 00 $000 $0 00 $0 00 $0 00 $0 00
2009 667592008 SD #121 SCHOOL DISTRICT #121 $0 00 $6 $0 00 $0 00 $0 00 $0 00
2009 667592008 NTH OLY LIB NORTH OLYMPIC LIBRARY $0 00 $0 00 $0 00 $0 00 $0 00 $0 00
2009 667592008 HO #2 HOSPITAL #2 $0 00 $0 00 $0 00 $0 00 $0 00 �$0 00
12009 667592008 FIRE PATROL FIRE PATROL $17 90 $0 00 $0 00 $0 00 $17 90 $0 00
http. /vpn.clallam.net 8084 /propertyaccess /Property aspx ?cid =0 &year= 2010 &prop_id =66 5/20/2010