Loading...
HomeMy WebLinkAbout3016ORDINANCE NO. 3016 AN ORDINANCE of the City of Port Angeles, Washington, amending the electrical code ordinance to allow certain updated electrical devices to be installed and to delete the requirements for disconnect devices on the outside of buildings and separate transfer switch devices for generator connections and amending Ordinance 2552 as amended and Chapter 14.05 of the Port Angeles Municipal Code. THE CITY COUNCIL OF THE CITY OF PORT ANGELES DOES HEREBY ORDAIN as follows: Section 1. Ordinance 2552 as amended and Chapter 14.05 of the Port Angeles Municipal Code are hereby amended by amending PAMC 14.05.160 to read as follows: 14.05.160 Wiring Methods. A. All buildings in the Downtown, Fire Zone 1 as defined in Chapter 14.24 PAMC, and any open space mall -type structures without fire wall separation, industrial zoned property, piers, docks, wharfs, structures over water, and permanent structures at the Clallam County fairgrounds, shall be wired in an approved raceway. or with MC cable (1 hour minimum fire wall rating) B. All mains and circuits exceeding 300 volts between conductors, and circuits exceeding 150 volts to ground, shall be installed in approved raceways. C. The fault duty rating of all service equipment shall exceed the available fault current. The minimum fault duty rating required on service equipment for non - dwelling installations shall be at least 20,000 AIC. D. Wood used for support or other purposes in electrical installations, in contact with the earth or subject to moisture, shall be commercially pressure treated and labeled for earth contact. E. Electric meters shall not be permitted inside buildings or within carports or porches without written approval of the Inspector. If an electric meter is made inaccessible, such as by the installation of a fence (with a locked gate or not gate) or other enclosure, the owner shall relocate the meter to an accessible location, as determined by the Inspector. if the electric meter is located behind a locked gate, the owner may provide an approved lock box rather than relocating the electric meter. 1 F. Where more than one electric meter is used, a permanent label shall be attached pn each meter base showing the apartment or unit number. G. In Residential Occupancies, 20 amp branch circuits will be limited to 20 outlets and /or lighting devices and 15 amp circuits will be limited to 15 devices. I. . 1 1 • - el • A transfcr switch uscd to conncct an cmcrgcncy gcncrator shall be a scparatc publication. Section 2 - Effective Date. This Ordinance shall take effect five days after the date of PASSED by the City Council of the City of Port Angeles at a regular meeting of said Council held on the 6th day of Apr i 1 ATTEST: APPROVED AS TO FORM: , 1999. Craig D. Knu on, City Attorney PUBLISHED: Apr i 1 11, 1999 99:03 By Summary 2 Summary of Ordinance Adopted by the Port Angeles City Council on April 6. 1999 Ordinance No. 3016 This Ordinance of the City of Port Angeles, Washington, amends the electrical code ordinance to allow certain updated electrical devices to be installed and to delete the requirements for disconnect devices on the outside of buildings and separate transfer switch devices for generator connections and amends Ordinance No. 2552, as amended, and Chapter 14.05 of the Port Angeles Municipal Code. The full text of the Ordinance is available at City Hall in the City Clerk's office or will be maile d upon request. Office hours are Monday through Friday from 8:00 a.m. to 5:00 p.m. This Ordinance shall take effect five days after the date of publication of this summary. Becky J. Upton City Clerk Publish: April 11. 1999