Loading...
HomeMy WebLinkAbout001058 Original ContractCity of Port Angeles Record # 001058 NET ENERGY METERING CONNECTION AGREEMENT for CUSTOMER FUEL CELL, SOLAR, WIND, or HYDROPOWER ELECTRIC GENERATING FACILITIES of 100 KILOWATTS or LESS This Net Energy Metering Connection Agreement is executed in duplicate this 5th day of April 7 20 16 between Port of Port Angeles (hereinafter referred to as "Customer "), and the City of Port Angeles Department of Public Works and Utilities (hereinafter referred to as the City). Both parties, who may be herein further referred to collectively as "Parties" and individually as "Party ", agree as follows: 1. CUSTOMER ELECTRIC GENERATING FACILITY 1.1 Customer has elected, in accordance with RCW 80.60 et seq., to operate either a net energy metering fuel cell, solar, wind or hydropower electric generating facility, with a generating capacity of not more than one hundred kilowatts, in parallel with the City's transmission and distribution facilities. This generating facility is intended to offset either part or all of the Customer's electrical requirements. 1.2 Customer's Application for Net Metered Electrical Generation, including the location of the electrical generating installation and details on the electrical generating unit(s) is hereby incorporated into this agreement as Appendix A. 1.3 The installation is identified by the City with the following designators: Transformer No. 45 -AS -08 , on feeder /phase F1202 /ABC Customer Utility Location No. 159768 1.4 A separate agreement shall be entered into for each Customer's electrical service location(s). 1.5 The electrical generating system used by the Customer shall be located on the Customer's premises. It shall include all equipment necessary to meet applicable safety, power quality, and connection requirements established by the National Electrical Code (Articles 690 and 705), National Electrical Safety Code, the Institute of Electrical and Electronics Engineers, Underwriters Laboratories, and the City's Connection Standards, as set forth in Appendix B, which is attached hereto. 1.6 The City shall have the sole authority to determine which connection requirements set forth herein are applicable to Customer's proposed installation. 2. PAYMENT FOR NET ENERGY 2.1 The City shall measure the net electricity produced or consumed by the Customer during each billing period, in accordance with normal metering practices. PW 1201 -01 Net Metering Agreement.DOC 1 of 6 3/28/01 2.2 If the electricity supplied by the City exceeds the electricity generated by the Customer and fed back to the City during the billing period, or any portion thereof, then the Customer shall be billed for the net electricity supplied by the City together with the appropriate customer charge paid by other customers of the City in the same rate class. 2.3 If the electricity generated by the Customer and distributed back to the City during the billing period, or any portion thereof, exceeds the electricity supplied by the City, then the Customer shall be: (a) billed for the appropriate customer service charge as other customers of the City in the same rate class; and (b) credited for the net excess kilowatt -hours generated during the billing period, with this kilowatt-hour credit appearing on Customer's bill for the following billing period. 2.4 At the beginning of each calendar year, any remaining unused kilowatt -hour credit accumulated by the Customer during the previous year shall be granted to the City without any compensation to the Customer. 2.5 Customer shall pay any amount owing for electric service provided by the City in accordance with applicable rates and policies. Nothing in this Section 2 shall limit City's rights under applicable Rate Schedules, Customer Service Policies, and General Provisions. 3. INTERRUPTION OR REDUCTION OF DELIVERIES 3.1 The City may require Customer to interrupt or reduce deliveries as follows: (a) when necessary in order to construct, install, maintain, repair, replace, remove, investigate, or inspect any of its equipment or part of its system; or (b) if it determines that curtailment, interruption, or reduction is necessary because of emergencies, force or compliance with prudent electrical practices. 3.2 Whenever possible, the City shall give Customer reasonable notice of the possibility that interruption or reduction of deliveries may be required. 3.3 Notwithstanding any other provision of this Agreement, if at any time the City determines that either: (a) the facility may endanger City personnel, or (b) the continued operation of Customer's facility may endanger the integrity of the City's electric system, The City shall have the right to disconnect Customer's facility from the City's electric system. Customer's facility shall remain disconnected until such time as the City is satisfied that the condition(s) referenced in (a) or (b) of this section 3.3 have been corrected. 4. CONNECTION 4.1 Customer shall deliver the excess energy to the City at the City's meter. PW 1201 -01 Net Metering Agreement.DOC 2 of 6 3/28/01 4.2 Customer shall pay for designing, installing, inspecting, operating, and maintaining the electric generating facility in accordance with all applicable laws and regulations and shall comply with the City's Connection Standards set forth in Appendix B, which is attached hereto. 4.3 Customer shall pay for the City's standard watt -hour meter electrical hook -up, if not already present. 4.4 Customer shall not commence parallel operation of the generating facility until written approval of the connection facilities has been given by the City. Such approval shall not be unreasonably withheld. The City shall have the right to have representatives present at the initial testing of Customer's protective apparatus. 5. MAINTENANCE AND PERMITS 5.1 Customer shall: (a) maintain the electric generating facility and connection facilities in a safe and prudent manner and in conformance with all applicable laws and regulations including, but not limited to, the City's Connection Standards, Appendix B, and (b) obtain any governmental authorizations and permits required for the construction and operation of the electric generating facility and connection facilities, including electrical permit(s). 5.2 Customer shall reimburse the City for any and all losses, damages, claims, penalties, or liability it incurs as a result of Customer's failure to obtain or maintain any governmental authorizations and permits required for construction and operation of Customer's generating facility or failure to maintain Customer's facility as required in (a) of this Section 5. 6. ACCESS TO PREMISES 6.1 The City may enter Customer's premises or property to: (a) inspect, with prior notice, at all reasonable hours, Customer's protective devices; (b) read meter; and (c) disconnect at the City's meter or transformer, without notice, the connection facilities if, in the City's opinion, a hazardous condition exists and such immediate action is necessary to protect persons, or the City's facilities, or property of others from damage or interference caused by Customer's electric generating facilities, or lack of properly operating protective devices or inability to inspect the same. 7. INDEMNITY AND LIABILITY 7.1 The Customer assumes the risk of all damages, loss, cost and expense and agrees to indemnify the City, its successors and assigns, and its respective directors, officers, employees and agents, from and against any and all claims, losses, costs, liabilities, PW 1201 -01 Net Metering Agreement.DOC 3 of 6 3/28/01 damages and expenses including, but not limited to, reasonable attorney fees, resulting from or in connection with performance of the agreement or which may occur or be sustained by the City on account of any claim or action brought against the City for any reason including but not limited to loss to the electrical system of the Customer, caused by or arising out of an electrical disturbance. 7.2 Such indemnity, protection, and hold harmless includes any demand, claim, suit or judgement for damages, death or bodily injury to all persons, including officers, employees or agents, and subcontractors of either Party hereto including payment made under or in connection with any Worker's Compensation Law or under any plan for employees' disability and death benefits or property loss which may be caused or contributed to by the connection, maintenance, operation, use, presence, or removal of Customer's equipment. The only exception will be liability occasioned by the sole negligence or willful misconduct of the City or its employees acting within the scope of their employment and liability occasioned by a partial negligence of the City or its employees acting within the scope of their employment to the extent that such partial liability is fixed by a court of competent jurisdiction. 7.3 The provisions of Section 7 shall not be construed to relieve any insurer of its obligations to pay any insurance claims in accordance with the provisions of any insurance policy. 7.4 The City shall have no liability, ownership interest, control or responsibility for the Customer's Electric Generating Facility or its connection with the City's electric system, regardless of what the City knows or should know about the Customer's Electric Generating Facility or its connection. 7.5 Customer recognizes that it is waiving immunity under Washington Industrial Insurance law, Title 51 RCW, and further agrees that this indemnification clause has been mutually negotiated. This indemnification shall extend to and include attorney's fees and the costs of establishing the right of indemnification hereunder in favor of the City. 8. INSURANCE 8.1 Customer shall maintain, during the term of this Agreement, Comprehensive Personal Liability Insurance with a combined single limit in an amount equivalent to the industry standard for this type of insurance. 8.2 Such insurance shall, by endorsement to the policy or policies, provide for thirty (30) calendar days written notice to the City prior to cancellation, termination, attention, or material change of such insurance. 8.3 The City shall have the right to inspect or obtain a copy of the original policy or policies of insurance. 9. INDEPENDENT CONTRACTORS 9.1 The Parties hereto are independent contractors and shall not be deemed to be partners, joint venturers, employees, franchisees or franchisers, servants or agents of each other for any purpose whatsoever under or in connection with this Agreement. PW 1201 -01 Net Metering Agreement.DOC 4 of 6 3/28/01 10. GOVERNING LAW 10.1 This Agreement shall be interpreted, governed, and constructed under the laws of the State of Washington as if executed and to be performed wholly within the State of Washington. Venue of any action arising hereunder or related to this agreement shall lie in Clallam County, Washington. 11. AMENDMENTS, MODIFICATIONS OR WAIVER 11.1 Any amendments or modifications to this Agreement shall be in writing and agreed to by both Parties. The failure of any Party at any time or times to require performance of any provision hereof shall in no manner affect the right at a later time to enforce the same. No waiver by any Party of the breach of any term or covenant contained in this Agreement, whether by conduct or otherwise, shall be deemed to be construed as a further or continuing waiver of any such breach or waiver of the breach of any other term or covenant unless such waiver is in writing. 12. APPENDICES The Agreement includes the following appendices attached and incorporated by reference: Appendix A: Customer's Application for Net Metered Electrical Generation to City of Port Angeles. Appendix B: City's Connection Standards for Customer Electric Generating Facilities of 100 Kilowatts or Less. 13. NOTICES All written notices shall be directed as follows: City of Port Angeles: Electrical Engineering Manager 321 East 5th Street P.O. Box 1150 Port Angeles, WA 98362 Customer: Port of Port Angeles Name P.O. Box 1350 Address Port Angeles, WA 98362 City, State & Zip PW 1201 -01 Net Metering Agreement.DOC 5 of 6 3/28/01 Customer notices to the City, pursuant to this Section 13, shall refer to the Service Address set forth in Appendix A. 14. TERM OF AGREEMENT This Agreement shall be in effect when signed by the Customer and the City and shall remain in effect thereafter month to month unless terminated by either Party on thirty (30) days' prior written notice in accordance with Section 13. 15. SIGNATURES IN WITNESS WHEREOF, the Parties hereto have caused two originals of this Agreement to be executed by their duly authorized representatives. This Agreement is effective as of the last date set forth below: CUSTOMER: CITY OF PORT ANGELES: C Ll- Signature Signat Chris Hartman Shailesh Shere Print name Director of Engineering Title 04/05/2016 Date Print name Electrical Engineering Manager Title 04/05/2016 Date PW1201 -01 Net Metering Agreement.DOC 6 of 6 3/28/01 {�.9II+ii t4C fl APPENDIX A Application for Net Metered Electrical Generation Thank you for your interest in establishing a renewable energy or fuel cell connection with City of Port Angeles, Electric Utility. Please note generation systems must meet certain requirements to be considered. • The project must be not more than 100 kilowatts (kW) in size. • Generation must be fueled by solar, wind, hydropower, or be a fuel cell. • Owner provides power conditioning, connection, and safety equipment. • Projects will be considered on a fast come first served basis. Please complete Customer and Installer Information and the appropriate section for the type of generation proposed to be installed. In addition, include a one -line diagram and description of protection equipment. Please allow at least ten working days for processing your application. Questions may be directed to Electrical Engineering Manager, at telephone number (360) 417 -4702. Customer Information Owner Name: Port of Port Angeles Mailing Address: P.o.Box 1350 City, State & Zip: Port Angeles, WA 98362 Email Address: ehrish @portofpa.com Service Address: 2220 W. 18th St., Port Angeles, WA 98362 (If different than Mailing Address) 2220 W. 18th St., Port Angeles, WA 98362 Daytime Telephone: 360- 452 -3959 Electric Utility Account No.: Expected System Operational Date: 5/19/2016 Installer Information (If different from Customer Information) Installer Name: A &R SOLAR Mailing Address: 2444 1 st Ave S. City, State & Zip: Seattle, WA 98134 Email Address: permits @a- rsolar.com Daytime Telephone: 206- 707 -9937 PW1201_02 [Revised 01/20161 1 of 2 Photovoltaic Solar Svstem Information PV Module Manufacturer: solar world PV Module Model Number: SW 260 PV Power Rating per Module: 260 Inverter Manufacturer: SNIA Inverter Model Number: (QTV.10) SMA S66000 -us Inverter's Power Rating (kW): 8kW DC Watts Number of Modules: 351 Total Output: 91.26kW DC Watts (AC continuous) Describe the protection equipment to be used and the physical location of the installation: Installation of a 91,26kW photovoltaic system on the roof, Inverters and electrical equipment to be located on the exterior South wall of the main building. Installation Cost Information Estimated cost of installation: 209,450 Drawings Attached: o one line ❑V/ manufacturers literature a design drawings PW1201_02 [Revised 01/2016] 2 of 2 `v- �r- N�*R SOIAR AND 1-1 S RECENOR POSSESS10iI UC;�� NK) F COIFE�' RiGHT IN OR LTCENS� TO USE 1TOk THE HT-RF IN NOP NNY RNGlif TO REPRGDUCE P,,Iz.; AN'Y PARF � / � ]� u 2u El 17- El :,o El El LE - - - - - - - - - - - - - - - - - > 7 0 6 NP, 11 co 4c cd � � � \ �\ � -711 < z \ \ \ \ \\ \ \3 Z Z, < jl O �t �r SMA Certifications Efficient Safe Simple • For countries that require UL • 97 peak efficiency • Galvanic isolation • Patented automatic grid certification ILiL 1741 /IEEE 15:7 • OptiCooll active temperature voltage detection" • Optional integrated AFCI management system • Integrated DC disconnect switch functionality meets the req*vnents of NEC 2011 690.11 SUNNY BOY 5000 -US / 6000 -US / 7000 -US / 8000 -US Versatile performer with UL certification The Sunny Boy 5000 -US, 6000 -US, 7000 -US and 8000 -US inverters are UL certified and feature excellent efficiency. Graduated power classes provide flexibility in system design. Automatic grid voltage detection* and an integrated DC disconnect switch simplify installation, ensuring safety as well as saving time. These models feature galvanic isolation and can be used with all types of modules — crystalline as well as thin -film. US Patent US735254s'81 ----- ------- ---- ------- Efficiency curve SUNNY BOY 8000-US 98 96 Sunny Boy 5000-US Sunny Boy 6000 -US Sunny Boy 7000-US Sunny Boy 8000 -US Technical data 8. :aS a; Combiner Box Simplify wiring for added .3 208VAC 240VAC 277VAC 208VAC 240VAC 277VAC 208VAC 240VAC 277VA 240VAC 277YAC Input (DC) E� IV,; s 345 V) a' ,� 4s Max. recommended PV power (@ module STC) 6250 W 7500 W 8750 W 10000 W Max. DC power (@ cos N = 1) 5300 W 6350 W 7400 W 8600 W Max. DC voltage 600 V 600 V 600 V 600 V DC nominal voltage 310V 310V 310V 345 V MPP voltage range 250 V - 480 V 250 V - 480 V 250 V - 480 V 300 V - 480 V Min. DC voltage / start voltage 250 V/ 300 V 250V/300V 250 V / 300 V 300 V/ 365 V Max. input current / per string (at DC disconnect) 21 A / 20 A 25A/20A 30A/20A 30A/20A 36 A @ combined terminal 36 A @ combined terminal 36 A @ combined terminal 36 A @ combined terminal Number of MPP trackers / fused strings per MPP tracker 1 / 4 (DC disconnect) Output (AC) Output power / Rated power ; I AC nominal power 5000 W 6000 W 7000 W 7680 W 8000 W Max. AC apparent power 5000 VA 6000 VA 7000 VA 7680 VA 8000 VA Nominal AC voltage /adjustable 208V/• 24OV /• 277V/• 208V/• 24OV /• 277V/• 208V /• 24oV /• 277V/ 4 240V/• 277V/• AC voltage range 183 -229V 211 -264V 244 -305V 183 -229V 211 -264V 244 -305V 183 -229V 211 -264V 244 -305 t 211 -264V 244 -305V AC grid frequency; range 60 Hz; 59.3 - 60.5 Hz 60 Hz; 59.3 - 60.5 Hz 60 Hz; 59.3 - 60.5 Hz 60 Hz; 59.3 - 60.5 Hz Max. output current 24A 21 A 18A 29A 25A 22A 34A 29A 25A 32A 29A Power factor (cos rp) 1 1 I 1 Phase conductors / connection phases 1/2 1/2 1/ 1 1/2 1/2 1/ 1 1/2 1/2 1/ 1 1/ 2 1/ l Harmonics <4% <4% <4 % <4% Efficiency Max. efficiency 967:0 968% 96.8% 96.9% 96.8% 97.0% 97.1% 96.9% 97.0% 96.3.0 96.5% CEC efficiency 95.5% 95.5% 95.5% 95.5% 95.5% 96.0% 95.5% 96.0% 96.0% 96.0% 96.0% Protection devices DC reverse - polarity protection • • • • Integrated AFCI* 0 O 0 O AC short circuit protection i • • • Galvanically isolated / allpole sensitive monitoring unit •% •% •/- •% Protection class / overvoltage category f J III 1 / III I / III General data Dimensions (W / H / D) in mm (in) 470/615/240 (18.5/24/9) DC Disconnect dimensions (W / H / D) in mm (in) 187/297/190 (7/12/7.5) Packing dimensions (W / H / D) in mm (in) 390/580/800 (16/23/31.5) DC Disconnect packing dimensions W1 H / D) in mm (in) 370 / 240 / 280 (15 / 9 / 1 1) Weight/ DC Disconnect weight - 64 kg (141 lb) / 3.5 kg (8 lb) 66 kg (145 lb) / 3.5 kg (8 lb) Packing weight J DC Disconnect packing weight 67 kg (147 Ib) / 4 kg (91b) 69 kg (152 lb) / 4 kg (9 lb) Operating temperature range (full power)** -25 *C ... +45 *C ( -13 *F ... +l l 3 ° F) Noise emission (typical) 44 dB(A) 45 dB(A) 46 dB(A) 49 dB(A) Internal consumption at night 0.1 W 0.1 W 0.1 W 0.1 W Topology LF transformer LF transformer LF transformer LF transformer Cooling concept Opticool Opticool Opticool Opticool Electronics protection rating / connection area NEMA 3R J NEMA 3R NEMA 3R / NEMA 3R NEMA 3R / NEMA 3R NEMA 3R / NEMA 3R Features Display: text line / graphic •J- •/- •/- •/- Interfaces: RS485 / Bluetooth" 0/0 0/0 0/0 0/0 Warranty: 10 / 15 / 20 years 6/0 /0 6/0/0 9/0/0 0/0/0 Certificates and permits (more available on request) ULI741 (Second Ed.), UL1998, UL1699B, IEEE 1547, FCC Part 15 (Class A & B), C C22.2 No. 107.1 -2001 * For AFCI functionality specify SBXXXXUS -12 when ordering. * *For extended operating temperature range to -40 *C (-40 °F), specify SBXXXXUS-1 1 or SBXXXXUS -12 when ordering. • Standard features O Optional features -Not available Data at nominal conditions NOTE: US inverters ship with gray lids. Type designation SB 5000US SB 6000US SB 7000US SB 8000US ----- ------- ---- ------- Efficiency curve SUNNY BOY 8000-US 98 96 94 87uetooth PggyBack s BTPBINV- - _...... ................. -.7 ...... BTPBEXTANT-NR 8. :aS a; Combiner Box Simplify wiring for added .3 ui5 Eta R',� ° 30:? Vl m 9a5 E� IV,; s 345 V) a' ,� 4s gl Q Et. N. B 4an YP 3 Vu� [vl V? 94 87uetooth PggyBack s BTPBINV- with'.at Anterma BTPBEXTANT-NR 8. i o a; Combiner Box Simplify wiring for added array combiner box COMBOSWITCH convenience and safety S8CB-63R or SBCB6-4 92 . m gl Q u I w 90 V? 88j 3. 86 5 0.0 0.2 04 0.6 0.8 1.0 ' Output power / Rated power ; I Toll Free +1 888 4 SMA USA www.SMA-America.com Accessories RS485 interface ' 485USPB-NR 87uetooth PggyBack s BTPBINV- with'.at Anterma BTPBEXTANT-NR Combi•Swilch DC disconnect and PV a; Combiner Box Simplify wiring for added array combiner box COMBOSWITCH convenience and safety S8CB-63R or SBCB6-4 SMA Power Balancer Set = PBLSBUS•10 -NR SMA America, LLC TUV Power controlled: otr }9�aa a Lowest measuring tolerance in industry ' DCCLi�7.A Every component is tested to meet 3 times IEC requirements J -- #T Designed to withstand heavy accumulations of snow and ice J �' Sunmodule Plus: Positive performance tolerance J xm�, 25 -year linear performance warranty and 10 ear product warrant Y P Y Glass with anti reflective coating J World -class quality Fully- automated production lines and seamless monitoring of the process and mate- rial ensure the qualitythat the company sets as its benchmark for its sites worldwide. SolarWorld Plus- Sorting Plus- Sorting guarantees highest system efficiency. SolarWorld only delivers modules that have greater than or equal to the nameplate rated power. 25 -year linear performance guarantee and extension of product warranty to 10 years SolarWorld guarantees a maximum performance digression of 0.7% p.a. in the course of 25 years, a significant added value compared to the two -phase warranties com- mon in the industry. In addition, SolarWorld is offering a product warranty, which has been extended to 10 years.` 'in accordance with the applicable SolarWorld Limited Warranty at purchase. www.solarworld.com/warranty solarworld.com s ovas C Ris UL 1703 ffi k S MADEIN GERMANY O S SW 260 MONO REALVALUE PERFORMANCE UNDER STANDARD TEST CONDITIONS (STC)' L 'A SIN 260 Maximum power ple�, 260 Wp Open circuit voltage V�, 38.9 V Maximum power point voltage 30.7 V Short circuit current 9.18 A Maximum power point current 8.56A Module efficiency v 15.51 % Measuring tolerance (P,,) traceable to I LJV Rheinland: /-2% (TUV Power controlled) 'STC: 1000VI/ml, 25'C, AM 15 PERFORMANCE AT 800 W/M2, NOCT, AM 1.5 SW 260 Maximum power P111, 194.2 Wp Open circuit voltage V, 35.6 V Maximum power paint voltage vmp 28.1 V Short circuit current 7.42 A Maximum power point current 6.92 A miri�l reti.c7, mefffci :y under p.4tial load ccidit-ons at 25' C: at 200 W /4',100 %( + / -2 ".) of the SIC efficiency (1000 W/ni') is achieved. 1000 W/nnx DIMENSIONS COMPONENT MATERIALS 800 W/nn Length 65.94 in (1675 mm) Cells per module 60 Width 39.41 in (1001 mm) Cell type Mono crystalline V 600 W/m= Height 1.22 in (31 mm) Cell dimensions 156 mm x 156 mm 400 W/rn' Frame Clear anodized aluminum Front Tempered glass (EN 12150) Weight 39.5 lbs (17.9 kg) 200 W/nn' 100 W/nn= THERMAL CHARACTERISTICS ADDITIONAL DATA M.d.W -10ge [V] V, NOCT A6,C Powersorting -0 Wp/+S Wp Tcl,, 0. -,nc J-Box IP65 TC V - 0 —3io C Module leads MC4/KSK4 TCP,, -afl X"'C Module type (UL 1703) 1 PARAMETERS FOR OPTIMAL SYSTEM INTEGRATION 31 37 (10,00) Maximum system voltage SCIIINEC 1000 V Maximum reverse current 25A 6S.9 :71ST' Load /dynamic load 113 pst/30 psf (5.4/2.4 kN/ml Number of bypass diodes 3 Operating range -40' C to +85' C ... i4 39,41(1001) 122 (.,1) All units pmvlded are ini.perial. Sl timis Provided in pafen-,hese5, Solar) orld AG reserves ualo specification changesvc,-,hotjr nonce. SW-01-6002US G 12-2014