Loading...
HomeMy WebLinkAbout1617 W 15th St - BuildingApplication Number Application pin number Property Address ASSESSOR PARCEL NUMBER Application type description Subdivision Name Property Use Property Zoning Application valuation Owner Contractor Special Notes and Comments When roof gutters are installed drains will located in dry wells or piped to approved storm drain locations 05/12/2005 04 16 PM SROBERDS No land use issues are noted Lot coverage is 21% Electrical load calculations and elctrical permits are required COMMENTS /ACTION NEEDED CITY OF PORT ANGELES PUBLIC WORKS ELECTRICAL DIVISION 121 EAST 5TH STREET PORT ANGELES WA 98362 05 0)000329 668873 1617 W 15TH ST 06 30 99 0 4 0760 0000 RES .DDITION RS7 RESDNTL SINGLE FAMILY 50000 Date 9/01/05 ACHESON MICHAEL B COZI HOMES CONSTRUCTION INC 1617 W 15TH ST 324 E 9TH ST PORT ANGELES WA 983636846 PORT ANGELES WA 98362 (360) 452 9906 Structure Information 000 000 588 SQ FT ADDITION Construction Type TYPE V NON RATED Other struct info TOTAL LOT COVERAGE 21 00 NUMBER OF STORIES 1 00 EXISTING LOT COVERAGE 2256 00 LOT SIZE 10494 00 NUMBER OF UNITS 1 00 Permit ELECTRICAL ALTER RESIDENTIAL Additional desc EL SVC 8 CIRCUITS Permit pin number 59246 Sub Contractor ELECTRIC SERVICE Permit Fee 69 30 Plan Check Fee 00 Issue Date 9/01/05 Valuation 0 Expiration Date 2/28/06 Qty Unit Charge Per Extension 1 00 48 1000 ECH EL R OR 1RM 1 4 ALT CIRCUITS 48 10 4 00 5 3000 ECH EL R OR RM ALT ADDNT CIRCUITS 21 20 Other Fees STATE SURCHARGE 4 50 Fee summary Charged Paid Credited Due Permit Fee Total 69 30 �9 30 00 00 Plan Check Total 00 00 00 00 Other Fee Total 4 50 4 50 00 00 Grand Total 73 80 '3 80 00 00 CALL 417 -4735 FOR ELECTRICAL INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE IT IS INSPECTED AND ACCEPTED. DITCH ROUGH -IN COVER SERVICE FINAL GENERAL COMMENTS: ELECTRICAL PERMIT INSPECTION RECORD KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED YES I NO 07; s COMMENTS PW- 1102.15 [4/96] ectrical Contractor Owner 0 Annual Permit O Alarm O Carnival 0 Commercial Residential O Residential Maint. O Signs Thermostat Telecom. Job wired by Electrical contractor name porchasEr's mailing City L J State ZIP w-••. 573 6'z- Telephone number er FAX number Li, 4 'Premise o name V k K2 c, 2S0 Address r t pjcnL Ili.. City s Inspection Date 9i, Z0 39Vd ectrical Contractor O Owner License number r -'o1/4, jr. Q (3 -.SI'I 13Z, ELECTRICAL WORK PERMIT APPLICATION O Request Inspection 11 'Installation description I hereby certify that I am the owner of the above named property or a licensed electrical contractor (or the firm's authorized agent) and am making the electrical installation or alteration in compliance with the electrical l law Chapter 19.28 RCW /SIgnaty+Fe )f owner, /ctrica tractor or electrical administrator Expiration X t I/ t 1 of card 0 WALLS CE TH ERMOSTAT SERVICE Insulation Only Insulation Only Dote Appro al By Due Approved By J Dale Approved By P Approved By Mar ER 1 q, z S Cover s Cover bo, �•n FEEDER ste Approves By bola Aprevee By I Dote Approved By Dale Approved By J Electrical Load Additions and or stthtractions O NO LOAD CHANGES O Baseboard KW O Fumace KW 0 Overhead Service Heat Pump Ton LAR O Temp Service Fan -Wall KW Underground Service Area, Building or Equipment Inspected O Cash O Check O Credit Card Card Service Information Voltage Phase 0 1 0 3 Service Size: Feeder Size; Action Taken Inspection fee Discover a I Electrical Inspector VZb9ZSt'09E TE S0 S00Z/10/60 s ~~ CITY OF PORT ANGELES , DEPARTMENT OF COMMumfy.l):EVELOPMENT - BUIT.DINGDIVISION 321 EAST 5TH STRBET,PORT ANGELES, W A 98362 , J";., Application Number Application pin number Property Address ASSESSOR PARCEL NUMBER: Application type description . Subdivision Name Use 05-00001166 Date 768406 1617 H 15TH ST 06-30-99-0-4~0760-0000~ MECHANICAL APPL:,PERMIT" 11/29/05 r , RS7 RESDNTl>SIN~~ ,FAMILY 3100 Contractor PELLET HEAT CO. 230",~T,lST SUITE ,C PORT ANGELES HA 98362 (360) .457:"'4406 HA 983636846 MECHANICAL PERMIT FREESTANDING PELLET STOVE 65920 50.00 Plan Check Fee 11/29/05 Valuation . . 5/28/06 .00 o Unit Charge Per 50.0000 ECH ME-HOOD Extension 50.00 Charged Paid Due 50.00 .00 50.00 .00 .00 .00 .00 .00 .00 t:',.i~;, \ -z,(z.?IAt'" ~V=- ' Separate Permits. are requiredfor electrical work, SEPA, 9horellne, ESA, utiUtl,es, priVate and public impro":~ITl~ry~'l11~;p~rjTlttbec()ines null and void If work or construction authorized is l'IotcomlTlsngedwithin 180:d,a~dfponstru9tlonorYlo~,1~i~u~p~rt,d.aflor~andoned for a period of 180 days after the work as commenced, or~ required Inspections have not been,requested,wlthin180,claySlromthe last Inspection. 'I hereby certify that I have read andexan,inE~atf1jsappJicatlon and know the same to be trueandcQrrect/A11 proVisions of laws and ordinances governing this type of work will pe q<?J1lpIlEKiwith whether ~pecified herein or not.. The, granting Of a permit does not presume to give authority to violate or cancel theprovi~iI)~s of any'state or'locallaw regulating conStiUetion or the'perfuimance of construction. ' ' Signature of Owner (if owner is builder) Date Date T:\Policics\1102_15 buildingpennit inspection record05.wpd [11412005] , .~ "- ~ ~ '"" ~ ,~ BUILDING PERMIT INSPECTION RECORD CALL 417-4815 FOR BUILDING INSPECTIONS. CALL 417-4735 FOR ELECTRICAL INSPECTIONS. CALL 417-4807 FOR PUBLIC WORKS UTILITIES . . PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. . POST PERMIT IN A CONSPICUOUS LOCATION. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE. ~' .. INSPECTION TYPE DATE. ACCEPTED COMMENTS I YES NO .. FOUNDATION: . FOOTINGS WALLS . FOUNDATION DRAINAGE I DOWN SPOUTS . PIERS POST HOLES (POLE BLDGS.) PLUMBING UNDER FLOOR I SLAB ROUGH-IN WATER LINE (ME~ TO BLDG) GAS LINE FINAL DATE ACCEPTED BY: BACK-FLOW I WATER AIR SEAL .. WALLS CEILING I . FRAMING JOISTS I GIRDERS SHEAR W ALLlHOLD DOWNS WALLS I ROOF I CEILING DRYWALL (INTERIOR BRACED PANEL ONLY) T-BAR . INSULATION .C SLAB WALL I FLooRI CEILING I I MECHANICAL HEAT PUMPI FURNACEI DUCTS I GAS LINE _. . 1-'2- /J'f / O} -..:1"l,...'- FINAL I ~/~/or'DATE WOOD STOVE I PELLET I CHIMNEY , '-- 7LL ACCEPTED BY: COMMERCIAL HOOD I DUCTS ' I MANUFACTURED HOMES .' FOOTING I SLAB BLOCKING & HOLD DOWNS SKIRTING PLANNING DEPT. SEPARATE PERMIT /#'5 SEPA: PARKINGlLIGHTlNG .. . ESA: LANDSCAPING C SHORELINE: .... . FINAL. INSPECTIONS REQUIRED PRIOR TO OCCUPANCYIUSE RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED YES NO ELECTRICAL - LIGHT DEPT. 417-4735 ELECTRICAL LIGHT DEPT CONSTRUCTION R. W.I PWI CONSTRUCTION - R. W. .... ENGINEERING 417-4807 , Pw I ENGINEERING I .' FIRE 417-4653' FIRE DEPT. " PLANNING DEPT. 417-4750 . / PLANNING DEPT. BUll..DING 417-4815 7;;'/:J.}/dr \. Ii-...... BUll..DING T:\Policies\II02 15 buil . 'Ii on record05. IMoo5 ding penm nspecti wpd [ 11 22 05; 2:33PM , ~ ~,... . + -- Fill out COMrL~TI!;L l' ano In 1.'(1\.,. .1 UUJ .............V.. ...... ~..v r~~~ :'- -,~ ~ -::- COMPLETE to b.lIcc"pted for rfl"flew. 1C YIJIJ h...t: an)' qUl!Stlon,. call (360) 4i 7-4fllS 360 452 0503;# 2 _........r-,....... .-. Dlt8Iuur:u,_iJr: 71&(L:J o(~ Applictllll or A~ent: ?t:LlK1'" ~ C-e Phone: 451~ ~~(o Owneor: t\AI \(~ A:..H~~J Phone: Address:~~ Cjt)':~ ~~ ~ Zip: Q83ba..__ Ar,hilcetlE~in.er: Phone' - contractor~~ ~_ '-.(l State Licens':1~""~lx.p:~ Phone:~_ Address: ~- Ca. J S'J City:..l:bcr A1-J6tSE'S. Zip:..9~2 PROJECT ADDRESS: ! k?I -, W I 2.!~ ZONING: LEGAL DBSCRlPTION: Lot_B Block: SubdivlSion: rPA ~~ 'SP e 7.. CLALLA.\'! COlT:'ITY PARCEL NtJMB'ER: ..o~q04Ci fL:JC~ 7 VIT> ~o Credit Card Holder N.I1l~: 8i11ul\( Al.Il.1rl:lQl; CredIt Cardlypt VISA_Me _ N .T)!'E OF WURK: ~ Re~i'knLitll CJ Nl3w Cons!]', 0 Re-roof K Stove ::J \hhj.family a Addltio%l Cl Move Cl Oan.ge --, t.-:;omm=rclQ.1 0 Remodel D DeLl"oCllition C DecK o Rtlfl8ir D Sign r:l Other BRU':F DESCRIPTION OF THE r'RO/TECL t t-J5mLL CUy: Exp. Date: SIZIJV AUlA. nON: SF.@$ ISF.-) SF. @ S ~ I::;F. =- S .'.___ SF.@$ IS'E'.;; S ~ TOTAL VALUATION $..3Im uU _ ~:1 J.J \...~ ----------- COUBtrUCti013 Type:,_.. '" TOTAL Sq.r:1. ~& COMMERCIALIRESIDEN1'lAL: Occupancy Group: Occupant Load: No. orSlOne,!: _ Lot S:zc: _ lWJting Sl.j, FI, It Proposed Sq. Ft F.xisting 101 covtrlge _ % Il Proposed lot co\'erugc _% - Totlllol CClVCra&O APPROV AI..S: I PLAN: ___ : BLOG: ' D}>WU: lI'l.RE:-==: OTHRR:_ [ P~1J'G USE ONLY: .. ~~"/W~t1anclts): 0 Yes C No SEPA ChecyJist rcquirtd7 t:l Yes 0 No Other: Rlln ,nfl'l/G PERMIT APPLlCi\TION Sll'BMlTIALI 'me Buildln& Division ~3.ll provide yuu wilh il1(Qrnultlol'lon the appli\,'.~tlOn:u1d riM. ~lJblllittal requiren'lCnta iryou hive qUllStiOns, "'A.l.U.<\'1'lON ur CONStRUCTION; In nil uaes, 1\ valu),Illnn amount mu.t b@tnteredbythe applie turt.. This figure will be rC\'J(:wnl .1J"d :1uy be revised by the Building Division tl) QtJmply with ~UlTent fee schedule,. Cuntact tht P~rrnit Coordinator it 417.4315 for usis tar.ce, l"LA." CHECK FEE: IF Il plan check ree is due: it must be &ubmitted at tho time the buildiD& pennit applicac10n wd CVl'll'lmr.til'lo pla.ns rue ~ubmittl'>tl. All other permit fees arc due It the time ofponnit iS~\I11nce. EXPTRA'nON 01' PLAN REVIEW: B'no pennll is i"ucd within 180 day, Oflll~ lblle n!"applieRtion, the IilppUcatJol1 will expire. Th(; El'J ild1."lg Official can ~ll.tend the time for acrion by the applicant up 10 180 day. upon written roqucllt by the applieanL (Nee Section 10: ,4 'J 1 the Uniform euildjn~ Code. C\lIrent edition). No llpplicllti('ln can be extended more than Dnce. / hereby certify tnat I hs\lS t'98d and 9xSfTltned fh/~ 8pp/lWion and know the same fo be I",~ end C()mjct. 111m authOr1ZBd to 8pply for rhls permil and 'JndersitJnd t/la/ K lIS my rt!sponsibillty 10 detD(min6 wllt/' perm"s are requlf90 ,not tns City'.~, s, must sLJch permits prior 10 wo,* r:J'nRI;1.<\^~t',"\I\~fhll1\prml\ ~d Applicant: DIne: II ' 1- %- -t:) J PREPARED 12/23/05, 12:39:26 CITY OF PORT ANGELES ADDRESS CONTRACTOR OWNER PARCEL . . APPL NUMBER: INSPECTION TICKET INSPECTOR: JAMES L LIERLY PAGE DATE 9 12/23/05 1617 15TH ST PELLET HEAT CO. ACHESON MICHAEL B 06-30-99-0-4-0760-0000- 05-00001166 MECHANICAL APPL. (360) 457-4406 SUBDIV: PHONE PHONE : PERMIT PERMIT: ME 00 MECHANICAL PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ME6 01 12/13/05 JLL 12/14/05 DA ME6 02 12/19/05 JLL 12/19/05 AP ME99 01 .~~ MECHANICAL GAS LINE 12/12/2005 12:21 PM PBARTHOL --------------------------- MIKE 457-4406 12/14/2005 09:22 AM PBARTHOL --------------------------- BLB ON GAUGE. NEEDS 24-30LBS AND RECALL INSPECTION MECHANICAL GAS LINE 12/15/2005 04:30 PM MIKE 457-4406 PERMIT ON TANK 12/19/2005 04:33 MECHANICAL FINAL 12/21/2005 12:32 MARY 452-7916 CALL FIRST PBARTHOL --------------------------- PM JLIERLY ---------------------------- TIME: 17: 00 PM PBARTHOL --------------------------- -------------------------------------- COMMENTS AND NOTES -------------------------------------- . ~~ CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY DEVELOPMENT - BUILDING DIVISION 321 EAST 5TH STREET,PORTANGELES, WA 98362 COZI HOMES CONSTRUCTION INC 324 E 9TH ST PORT ANGELES (360) 452-9906 000 588 SQ.FT ADDITION TYPE V NON-RATED TOTAL % LOT COVERAGE NUMBER OF STORIES EXISTING LOT COVERAGE LOT SIZE NUMBER OF UNITS .' . . '" .. .'~.~ -'" Application Number ,,,.~.,.~.c~~:!J;lp,. pin number Prbperty"Address ASSBSSORPARCBL NUMBBR: ,'. ,..~~I;.:i:o~"type description SubdivisiOn,Name Property Use Property Zoning . . . Application valuation 05~00000329 Date 668873 1617 W 15TH. ST 06-30-99-0-4-0760-0000- RES ADDITION RS7 RESDNTL SINGLE FAMILY 50000 _~j 1\ '.. ,--,.-~,g'n..' .:,..-_ Contractor ACHESON MICHAEL B .'.. "~-','!.Q~T,W..)..5:r~,R..o;r PORTANG~LES WA 983636846 Structure Information 000 Construction Type Other struct info . . .......,,\"'~...........~~-""1..,--..""'_1 5/23/05 " -'-.~,'" --'. ',..,".' ~"..: WA 98362 21.00 1.00 2256.00 10494.00 '. ,..1.J~.0._,,_ --------:---------------------------------------------~----------~----------- Permit . . . . _ Additional desc . Permit pin number "'--""'Pl!-rm:rt' <Pee' "'. Issue Date . . Expiration Date . BUILDING PERMIT -RESIDENTIAL 588SF ADDNT ,4. ' .' 49312 667.25 Plan Check Fee 5/23/05 Valuation 11/19/05 Qty Unit Charge Per BASB FEE 25.00 10.1000 THOU BL-25.001-50K (10.10 PERK) Special Notes and Comments ........""'1Ihen',.roof. ~tters are installed, drains will located in dry" wells or piped to approved storm drain locations. 05/12/2005 04:16 PM SROBBRDS ---------~-----------~----- . No land use issues are noted. Lot coverage is 21%. ....._.,..ro.~e.~~i~a~.~oad calculations and elctrical permits ar~, requ1reu. 266';'90 . 50000 Extension ... 414.75 252.50 Other Fees STATE SURCHARGB ---------------------------------------------------------------------------- 4.50 -------------------------------------~-------------------------------------- Fee summary Charged Paid Credited Due' ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 667.25 667.25 .00 .00 . "-~._.<_pl>an. Check ,.Total 266.90 266.90 .00 .00', Other,Fee Total 4.50 4.50 .00 .00 Grand Total 938.65 938.65 .00 .00 ~.~ '..., :-,--..:,' ~ ~~. ~\ """"- ~.. - -.:J t 07 '1: (Y\ " ~ 1 Separ",te.permlts are required for electrical work, SEPA, Shqreline, ESA, utilities, private and public improvements. This permit becomes null.andvoid if work or construction authorized is not commenced within 180 days, if construction or work Is suspended or abandoned for a periOd of 180 days after the work as commenced, or If required Inspections have not been requested within 1.80 days from the last Inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws'and'ordinances governing this type of work will be complied with whether specified herein or not. The granting otape.rmit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. $'" :)..3 r-I?$ ture of Contractor or Authorized Agent Date Signatureof Owner (if owner is builder) T:\Policies\1102_IS building permit inspection reco~dOS.wpd [1/4I2OOS) ~;,~>' "",:,,,;:,j,;,,' .:' Date BUILDING PERMIT INSPECTION RECORD CALL 417-4815 FOR BUILDING INSPECTIONS. CALL 417-4735 FOR ELECTRICAL INSPECTIONS. CALL 417-4807 FOR PUBLIC WORKS UTILITIES PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATEOR CONCEAL ANY WORJ{BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECfION TYPE DATE ACCEPTED COMMENTS YES ' I NO -, ,'.' FOUNDATION: FOOTINGS - "'-f ,.!itfJ.c~ .d'A.F _/ ',' '~~ WALLS 1-21~ .:::JLL FOUNDATION DRAINAGE 1 DOWN SPOlJI'S , PIERS POST HOLES (POLE BLDGS.) - PLOMBING UNDER FLOOR 1 SLAB ROltGH-IN WATER LINE (METER TO BLDG) GAS LINE ,,- " BACK FLOW 1 WATER ", - AIR SEAL " , WALLS Iq-7-<9.r:: ..H.l CEILING " I , , FRAMING JOISTS 1 GIRDERS SHEAR W ALLIHOLD DOWNS WALLS 1 ROOF 1 CEILING q~2-0t::. .. \ LL.. DRYWALL (INTERIOR BRACED PANEL ONLY) T.BAR " INSULATION SLAB WALL 1 FLOOR 1 CEILING '(:/...1"]... 0<<: I~U.L I MECHANICAL HEAT PUMP 1 FURNACE 1 DUCTS f GAS LINE 1/a..I/11i IIJ r ' --ru..., WOOD STOVE 1 PELLET 1 CHIMNEY , " COMMERCIAL HOOD 1 DUCTS , MANUFACTURED HOMES FOOTING 1 SLAB BLOCKING & HOLD DOWNS SKIRTING , PLANNING DEPT. SEPARATEPERMIT#'s SEPA: PARKINGILIGHTING ESA: LANDSCAPING .. . "". SHORELINE: " FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCYIUSE - ' .> , RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED -YES 'NO - I"i ELECTRICAL - LIGHT DEPT. 417-4735 ELECTRICAL , LIGHT DEPT CONSTRUCTION R. W.I PWI CONSTRUCTION - R.W. ENGINEERING 417-4807 PW 1 ENGINEERING -1,- , FIRE 417-4653 FIRE DEPT. t " , PLANNING DEPT. 417-4750 -, PLANNING DEPT. '," BUILDING 417-4815 V~ I 0(, cru.-- BUILDING T:\Policies\1102_15 building pennit inspection record05.wpd (1/412005) PREPARED 1/03/06, 13:36:48 CITY OF PORT ANGELES ADDRESS CONTRACTOR OWNER PARCEL . . APPL NUMBER: INSPECTION TICKET INSPECTOR: JAMESL LIERLY PAGE DATE 1 1/03/06 1617 15TH ST COZI HOMES CONSTRUCTION INC ACHESON MICHAEL B 06-30-99-0-4-0760-0000- 05-00000329 RES ADDITION (360) 452-9906 SUBDIV: PHONE PHONE : PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL1 01 7/20/05 JLL 7/20/05 AP BI2 01 7/21/05 JLL 7/21/05 AP BL3 01 9/02/05 JLL 9/02/05 AP BAIR 01 9/06/05 JLL 9/07/05 DA BAIR 02 9/07/05 JLL 9/07/05 AP BLI 01 9/07/05 JLL 9/07/05 AP BL99 01 ~ ~ BUILDING FOUNDATION FOOTING 07/19/2005 01:57 PM DYASUMUR GERRATT 460-8557 07/19/2005 03:08 PM JLIERLY ---------------------------- 07/20/2005 04:07 PM JLIERLY ---------------------------- BUILDING FOUNDATION WALL 07/20/2005 02:18 PM DYASUMUR GARRET 460-8557 EARLY IN P.M. AFTER NOON SO THEY CAN POUR IN P.M. SAME DAY 07/21/2005 03:35 PM JLIERLY ---------------------------- BUILDING FRAMING 08/31/2005 11:13 AM PBARTHOL KEN 460-0036 **** CALL 1ST **** 09/02/2005 04:25 PM JLIERLY ---------------------------- BUILDING AIR SEAL TIME: 17:00 KEN 460-0036 09/07/2005 12:29 PM JLIERLY ---------------------------- finish airsea1 and reca11/j11 BUILDING AIR SEAL 09/06/2005 03:43 PM PBARTHOL KEN ZIGLER 460-0036 09/07/2005 04:53 PM JLIERLY ---------------------------- BUILDING INSULATION TIME: 17:00 KEN 460-0036 09/06/2005 09:17 AM PBARTHOL --------------------------- 09/07/2005 04:54 PM JLIERLY ---------------------------- BUILDING FINAL TIME: 13:00 12/29/2005 09:35 AM DYASUMUR --------------------------- CALL COZI HOMES @ 460-0036 BEFORE GOING, HE HAS KEYS. -------------------------------------- COMMENTS AND NOTES -------------------------------------- PREPARED 12/19/05, 13:43:45 CITY OF PORT ANGELES INSPECTION TICKET INSPECTOR, JAMES L LIERLY PAGE DATE 6 12/19/05 ADDRESS CONTRACTOR OWNER PARCEL . . APPL NUMBER: 1617 15TH ST PELLET HEAT CO. ACHESON MICHAEL B 06-30-99-0-4-0760-0000- 05-00001166 MECHANICAL APPL. SUBDIV: PHONE PHONE : (360) 457-4406 PERMIT PERMIT: ME 00 MECHANICAL PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ ME6 01 12/13/05 JLL 12/14/05 DA MECHANICAL GAS LINE 12/12/2005 12:21 PM PBARTHOL --------------------------- MIKE 457-4406 12/14/2005 09:22 AM PBARTHOL --------------------------- aLB ON GAUGE. NEEDS 24-30LBS AND RECALL INSPECTION MECHANICAL GAS LINE 12/15/2005 04:30 PM PBARTHOL --------------------------- MIKE 457-4406 PERMIT ON TANK ME6 02 ~~ -------------------------------------- COMMENTS AND NOTES ----------------------------------____ ~ BUILDING DIVISION CITY OF PORT ANGELES * * Correction Notice " " Job Located at -tGD vd i\., l~- Inspection of your work revealed that the fOllowing is not in accordance with the codes governing the work in this jurisdiction: fz<f11 (il-~' =; L$s < /;S", CAlf-I:: s AI~<ii.t') :2:.' - .' C') t-Bs -' ~et~ rA/$/fq;r~",; These corrections must be made and are not to be covered until reinspection is made. When corrections have been made, please call 4/7., 'flY <.;: :~t~nsP::~~:i&r $:!:f: , / ....Inspector for Building Division DO NOT REMOVE THIS TAG PREPARED 12/13/05, 12:59:04 CITY OF PORT ANGELES INSPECTION TICKET INSPECTOR: JAMES L LIERLY PAGE DATE 6 12/13/05 ADDRESS CONTRACTOR OWNER ,PARCEL , , APPL NUMBER: 1617 15TH ST PELLET HEAT CO, ACHESON MICHAEL B 06-30-99-0-4-0760-0000- 05-00001166 MECHANICAL APPL, SUBDIV: PHONE PHONE : (360) 457-4406 PERMIT PERMIT: ME 00 MECHANICAL PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ME6 01 12/13/05 /d-/I".P JLL ])/4- MECHANICAL GAS LINE 12/12/2005 12:21' PM PBARTHOL --------------------------- MIKE 457-4406 -------------------------------------- COMMENTS AND NOTES -------------------------------------- PREPARED 9/07/05, 12:50:43 CITY OF PORT ANGELES ADDRESS CONTRACTOR OWNER PARCEL . . APPL NUMBER: INSPECTION TICKET INSPECTOR: JAMES'L LIERLY PAGE DATE 5 9/07/05 1617 W 15TH ST COZI HOMES CONSTRUCTION INC ACHESON MICHAEL B 06-30-99-0-4-0760-0000- 05-00000329 RES ADDITION (360) 452-9906 SUBDIV: PHONE PHONE : PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BLl 01 7/20/05 JLL 7/20/05 AP BI2 01 7/21/05 JLL 7/21/05 AP BL3 01 9/02/05 JLL 9/02/05' AP BAIR 01 9/06/05 JLL 9/07/05 DA BAIR 02 -!f!(;k J~ BLI 01 # JfJrJ b~ BUILDING FOUNDATION FOOTING 07/19/2005 01:57 PM DYASUMUR GERRATT 460-8557 07/19/2005 03:08 PM JLIERLY ---------------------------- 07/20/2005 04:07 PM JLIERLY ---------------------------- BUILDING FOUNDATION WALL 07/20/2005 02:18 PM DYASUMUR GARRET 460-8557 EARLY IN P.M. AFTER NOON SO THEY CAN POUR IN P.M. SAME DAY 07/21/2005 03:35 PM JLIERLY ---------------------------- BUILDING FRAMING 08/31/2005 11:13 AM PBARTHOL KEN 460-0036 **** CALL 1ST **** 09/02/2005 04:25 PM JLIERLY ---------------------------- BUILDING AIR SEAL TIME: 17:00 KEN 460-0036 09/07/2005 12:29 PM JLIERLY ---------------------------- finish airseal and recall/jll BUILDING AIR SEAL 09/06/2005 03:43 PM PBARTHOL KEN ZIGLER 460-0036 BUILDING INSULATION TIME: 17:00 KEN 460-0036 09/06/2005 09:17 AM PBARTHOL --------------------------- -------------------------------------- COMMENTS AND NOTES --------------------------------_----- PREPARED 9/02/05, 12:29:~4 CITY OF PORT ANGELES ADDRESS CONTRACTOR OWNER PARCEL . . APPL NUMBER: INSPECTION TICKET INSPECTOR: JAMES L LIERLY PAGE DATE 3 9/02/05 1617 W 15TH ST COZI HOMES CONSTRUCTION INC ACHESON MICHAEL B 06-30-99-0-4-0760-0000- 05-00000329 RES ADDITION (360) 452-9906 SUBDIV: PHONE PHONE : PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL1 01 7/20/05 JLL 7/20/05 AP BI2 01 7/21/05 JLL 7/21/05 AP BL3 01 ~+- BUILDING FOUNDATION FOOTING 07/19/2005 01:57 PM DYASUMUR GERRATT 460-8557 07/19/2005 03:08 PM JLIERLY ---------------------------- 07/20/2005 04:07 PM JLIERLY ---------------------------- BUILDING FOUNDATION WALL 07/20/2005 02:18 PM DYASUMUR GARRET 460-8557 EARLY IN P.M. AFTER NOON.SO THEY CAN POUR IN P.M. SAME DAY 07/21/2005 03:35 PM JLIERLY ---------------------------- BUILDING FRAMING 08/31/2005 11:13 AM PBARTHOL KEN 460-0036 **** CALL 1ST **** -------------------------------------- COMMENTS AND NOTES -------------------------------------- PREPARED 9/06/05, 12:20:44 CITY OF PORT ANGELES INSPECTION TICKET INSPECTOR: JAMES L LIERLY PAGE DATE 6 9/06/05 ADDRESS CONTRACTOR OWNER PARCEL . . APPL NUMBER: 1617 W 15TH ST COZI HOMES CONSTRUCTION INC ACHESON MICHAEL B 06-30-99-0-4-0760-0000- 05-00000329 RES ADDITION SUBDIV: PHONE PHONE : (360) 452-9906 PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL1 01 7/20/05 7/20/05 JLL AP BUILDING FOUNDATION FOOTING 07/19/2005 01:57 PM DYASUMUR GERRATT 460-8557 07/19/2005 03:08 PM JLIERLY ---------------------------- 07/20/2005 04:07 PM JLIERLY ---------------------------- BUILDING FOUNDATION WALL 07/20/2005 02:18 PM DYASUMUR GARRET 460-8557 EARLY IN P.M. AFTER NOON SO THEY CAN POUR IN P.M. SAME DAY 07/21/2005 03:35 PM JLIERLY ---------------------------- BUILDING FRAMING 08/31/2005 11:13 AM PBARTHOL KEN 460-0036 CALL 1ST **** 09/02/2005 04:25 PM JLIERLY ---------------------------- BAIR 01 ~06 05 fN'\.,~_ BUILDING AIR SEAL TIME: 17:00 ~~ KEN 460-0036 ----------- -- ----------------------- COMMENTS AND NOTES -------------------------------------- 01 7/21/05 7/21/05 JLL AP BI2 BL3 01 9/02/05 9/02/05 JLL AP PREPARED 7/21/05, 13:36:48 CITY OF PORT ANGELES INSPECTION TICKET INSPECTOR: JAMES L LIERLY PAGE DATE 7 7/21/05 ADDRESS CONTRACTOR OWNER PARCEL . . APPL NUMBER: 1617 W 15TH ST COZI HOMES CONSTRUCTION INC ACHESON MICHAEL B 06-30-99-0-4-0760-0000- 05-00000329 RES ADDITION SUBDIV: PHONE PHONE : (360) 452-9906 PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL1 01 7/20/05 JLL 7/20/05 AP BUILDING FOUNDATION FOOTING 07/19/2005 01:57 PM DYASUMUR GERRATT 460-8557 07/19/2005 03:08 PM JLIERLY ---------------------------- 07/20/2005 04:07 PM JLIERLY ---------------------------- BUILDING FOUNDATION WALL 07/20/2005 02:18 PM. DYASUMUR GARRET 460-8557 EARLY IN P.M. AFTER NOON SO THEY CAN POUR IN P.M. SAME DAY BI2 01 ~ -------------------------------------- COMMENTS AND NOTES -------------------------------------- PREPARED 7/20/05, 12:59:04 CITY OF PORT ANGELES INSPECTION TICKET INSPECTOR: JAMES L LIERLY PAGE DATE 4 7/20/05 ADDRESS CONTRACTOR OWNER PARCEL . . APPL NUMBER: 1617 W 15TH ST COZI HOMES CONSTRUCTION INC ACHESON MICHAEL B 06-30-99-0-4-0760-0000- 05-00000329 RES ADDITION SUBDIV: PHONE PHONE : (360) 452-9906 ------------------------------------------------------------------------------------------------ PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS -------------------------------------~--------------~------------------------------------------- BL1 01 ~.~ BUILDING FOUNDATION FOOTING 07/19/2005 01:57 PM DYASUMUR GERRATT 460-8557 07/19/2005 03:08 PM JLIERLY ---------------------------- -------------------------------------- COMMENTS AND NOTES ------------------------------------__ BUILDING PERMIT - A):>>PLlCATION Date Issued: Fill out COMPLETELY and in INK. Your application and site plan MUST COMPLETE to be accepted for review. If you have any questions, cal PERMITS (360) 417-4815 FAX(360)417-4711 Applicant or Agent: /l4"A/k G-~;(/ ~ ~C/fI1'l5CT" Phone: L./S"7-rS-2.3 I .' Owner: /WI /<~ -1 ,41~~V /<~ /It:::fft5Sl::JN Phone: Address: /c'/7 W. /57H S"T;'ft!!1t!JfT City: ;Ptt1~r 4-~~ Architect/Engineer: MAlI< G6'>"'N /G/~~6";,v' ~,o Phone: /'" Ii ~ I Contracto~ L-O 3-1 t-If?n1€pS State License #: - Exp: - Phone: Address: - City: - Zip: PROJECT ADDRESS: /&'/7 #'- /.~rd 5"7"-. ; ~ltr ~~ ZONING: /(S-7 . ,/ LEGAL DESCRIPTION: Lot:&.f f1IJf (1 Block: Jf () 7 Subdivision: T,P A CLALLAM COUNTY PARCEL NUMBER: _t!J{., 3-0 ~ Cfn Ii V t"f roo tJ)(9(9-(!)- Zip: 9'?3~:3 0/5" 7-952-~ Credit Card Holder Name: Billing Address: City: Credit Card Type VISA MC # Exp. Date: TYPE OF WORK: SIZEN ALUATION: p(Residential 0 New Constr. 0 Re-roof 0 Stove SF. @ $ /SF.7$ -- o Multi-family )(Addition 0 Move 0 Garage SF. @$ /SF. = $ /' o Commercial ""Remodel 0 Demolition 0 Deck SF. @$ /SF. = $'/ o Repair 0 Sign 0 Other TOTAL VALUATION $ ~() / Clt:)O BRIEF DESCRIPTION OF THE PROJECT: eM~~~~ /?~ ~O/T7&V A-vL:? /1t/'Tm.t~ /</~ ;<(~('-X/e't-- . . CO:MMERCIALIRESIDENTIAL: Occupancy Group: Occupant Load: Construction Type: No. of Stories: ?. Lot Size: (0,'-1'1'" ExistingSq.Ft.1-;~ & Proposed Sq. Ft. G"B8 =TOTALSq.Ft. zalS Total lot coverage ~ I I % ~ e/C/sr. ~r/feM/r ':: / ~~8 1- PIlIP': 6'~8 t:t> ;:f!t.~{- =- 2/ APPROVALS: PLAN: BLDG: DPWU: FIRE: OTHER:_ PLANNING USE ONLY: ESNWetland(s): 0 Yes 0 No SEPA Checklist required? 0 Yes 0 No Other: VALUATION OF CONSTRUCTION: In all cases, a valuation amount must be entered by the applicant. This figure will be reviewed and may be revised by the Building Division to comply with currentfee schedules. Contact the Permit Coordinator at 417 -4815 for assistance. PLAN CHECK FEE: IF a plan check fee is due it must be submitted at the time the building permit application and cohstruction plans are submitted. All other permit fees are due at the time of permit issuance. EXPIRATION OF PLAN REVIEW: If no permit is issued within 180 days of the date of application, the application will expire. The Building Official can extend the time for action by the applicant up to 180 days upon written request by the applicant (see Section R105.3.2 of the International BuildinglResidential Code, 2003). No application can be extended more than once. . I hereby certify that I have read and examined this application and know the same to be true and correct. I am authorized to apply for this permit and understand that it is my responsibility to determine what permits are required ,not the City's, and that I must obtain such permits prior to work. nRVESSIBLDG-fu=-b,oob=\2004-Buildmgponnit.wpd APPli~~ .Dat" -r - :2-7 -t:7~ r4 ~ .J " Multi-Loaded Beamr 2003 International BuildinQ Code (01 NOS) 1 Ver: 6.00.7 By: Henry W. Gibson, Gibson Design Group on: 04-28-2005 : 11 :41 :39 AM Proiect: ACHESON - Location: Beam 1 - Ridge Beam Summary: . 5.125 IN x 22.5 IN x 33.0 FT (3 + 28 + 2) /24F-V4 - Visually Graded Western Species - Dry Use Section Adequate By: 17.0% Controlling Factor: Moment of Inertia / Depth Required 21.35 In Left Cantilever Deflections: Dead Load: Live Load: Total Load: Center Span Deflections: Dead Load: Live Load: Total Load: Right Cantilever Deflections: Dead Load: Live Load: Total Load: Center Span Left End Reactions (Support A): Live Load: Dead Load: Total Load: BearinQ LenQth Required (Beam only, support capacity not checked): Center Span RiQht End Reactions (Support B): Live Load: Dead Load: Total Load: BearinQ LenQth Required (Beam only, support capacity not checked): Dead Load Uplift F.S.: Beam Data: Left Cantilever LenQth: Left Cantilever Unbraced LenQth-Top of Beam: Left Cantilever Unbraced Length-Bottom of Beam: Center Span LenQth: Center Span Unbraced LenQth-Top of Beam: Center Span Unbraced Length-Bottom of Beam: RiQht Cantilever LenQth: RiQht Cantilever Unbraced LenQth-Top of Beam: RiQht Cantilever Unbraced Length-Bottom of Beam: Live Load Duration Factor: Live Load Deflect. Criteria: Total Load Deflect. Criteria: Left Cantilever Loading: Uniform Load: Live Load: Dead Load: Beam Self Weight: Total Load: Point Load 1 Live Load: Dead Load: Location (From left end of span): Center Span Loading: Uniform Load: Live Load: Dead Load: Beam Self Weight: Total Load: Trapezoidal Load 1 Left Live Load: Left Dead Load: RiQht Live Load: RiQht Dead Load: Load Start: Load End: Load LenQth: RiQht Cantilever Loading: Uniform Load: Live Load: Dead Load: Beam Self Weight: Total Load: Point Load 1 Live Load: Dead Load: Location (From left end of span): Properties For: 24F-V4- Visually Graded Western Species Bending Stress: DLD-Left= LLD-Left= TLD-Left= OLD-Center- LLD-Center= TLD-Center= DLD-RiQht= LLD-RiQht= TLD-Right= LL-Rxn-A= DL-Rxn-A= TL-Rxn-A= BL-A= LL-Rxn-B= DL-Rxn-B= TL-Rxn-B= BL-B= FS= L1= Lu1-Top= Lu1-Bottom= L2= Lu2-Top= Lu2-Bottom= L3= Lu3- T op= Lu3-Bottom= Cd= U U wL-1= wD-1= BSW= wT-1= PL 1-1 = PD1-1= X1-1= wL-2= wD-2= BSW= wT-2= TRL-Left-1-2= TRD-Left-1-2= TRL-RiQht-1-2= TRD-Right-1-2= A-1-2= B-1-2= C-1-2= r - ;)--~ "Or; wL-3= wD-3= BSW= wT-3= PL 1-3= PD1-3= X1-3= Fb= -0.10 IN -0.15 IN = 2U470 -0.26 IN = 2U281 0.30 IN 0.45 IN = L/754 0.75 IN = U449 -0.07 IN -0.10 IN = 2U476 -0.17 IN = 2U283 4314 LB 3058 LB 7372 LB 2.21 IN 3848 LB 2742 LB 6590 LB 1.98 IN 1.5 3.0 FT 2.0 FT 2.0 FT 28.0 FT 2.0 FT 2.0 FT 2.0 FT 2.0 FT 2.0 FT 1.00 360 240 0 PLF 0 PLF 28 PLF 28 PLF 300 LB 180 LB 1.0 FT 175 PLF 105 PLF 28 PLF 308 PLF 113 PLF 68 PLF 113 PLF 68 PLF 0.0 FT 24.0 FT 24.0 FT 0 PLF 0 PLF 28 PLF 28 PLF 225 LB 135 LB 2.0 FT 2400 PSI 'f PaQe:2 Multi-Loaded Beam[ 2003 International BuildinQ Code (01 NOS) 1 Ver: 6.00.7 By: Henry W. Gibson. Gibson Design Group on: 04-28-2005 : 11 :41 :39 AM Project: ACHESON - Location: Beam 1 - Ridge Beam Shear Stress: Modulus of Elasticity: Stress Perpendicular to Grain: BendinQ Stress of Compo Face in Tension: Adjusted Properties Fb' (Tension): Adjustment Factors: Cd=1.00 CI=0.99 Cv=0.91 Fv= Ex= Ey= Fc perp= Fb_cpr= Fb'= Fv': Fv'= Adiustment Factors: Cd=1.00 Design ReQuirements: ControllinQ Moment: M= 14.0 Ft from left support of span 2 (Center Span) Critical moment created by combining all dead loads and live loads on span(s) 2 ControllinQ Shear: V= At a distance d from left support of span 2 (Center Span) Critical shear created by combining all dead loads and live loads on span(s) 1, 2 Comparisons With ReQuired Sections: Section Modulus (Moment): SreQ= S= Area (Shear): AreQ= A= Moment of Inertia (Deflection): IreQ= 1= 240 1800000 1600000 650 1850 PSI PSI PSI PSI PSI PSI 2192 240 PSI 46701 FT-LB 5988 LB 255.65 IN3 432.42 IN3 37.43 IN2 115.31 IN2 4159.22 IN4 4864.75 IN4 1- Multi-Loaded Beam[ 2003 International Building Code (01 NDS)] Ver: 6.00.7 By: Henry W. Gibson, Gibson Design Group on: 04-28-2005 Project: ACHESON - Location: Beam 1 - Ridge Beam Summary: 5.125 IN x 22.5 IN x 33.0 FT (3 + 28 + 2) /24F-V4 - Visually Graded Western Species - Dry Use Section Adequate By: 17.0% Controlling Factor: Moment of Inertia / Depth Required 21.35 In SHEAR, MOMENT, AND DEFLECTION DIAGRAMS Load combination shown: Controllin Shear/Moment/Deflection Dia rams 7000 6808 Ibs @ 3 ft 3500 Shear (Ibs) 0 46701 ft-Ibs 17 ~ I I I -3500 -7000 50000 25000 Moment (ft-Ib) 0 -25000 -50000 -0.8 -486 ft-Ibs @ 3 ft in @ 0 ft -0.4 Deflectio'n (in) 0 0.8 0.749 in @ 1 Center Span = 28 ft 0.4 Left Cantilever = 3 ft Right C ntilever = 2 ft Controllina Load Cases: Shear: Critical shear created by combining all dead loads and live loads on span(s) 1, 2 Moment: Critical moment created by combining all dead loads and live loads on span(s) 2 Deflection: Critical deflection created by combining all dead loads and live loads on span(s) 2 LOADING DIAGRAM P1 P1 ~ : : : ~ --- A Left Cantilever +3 ft , Center Span = 28 ft B Right qanti'lev~r = 2 ft Reactions Live Load A 4314 Lb B 3848 Lb Dead Load Total Load Uplift Load 3058 Lb 7372 Lb 0 Lb 2742 Lb 6590 Lb 0 Lb Left Cantilever . Page 2 Uniform Loading Live Load Dead Load Self Weiaht Total Load W OPlf o Plf 28 Plf 28 Plf Point Loading Live Load Dead Load Location P1 300 Lb 180 Lb 1 Ft Center Span Uniform Loading Live Load Dead Load Self Weiaht Total Load W 175 Plf 1 05 Plf 28 Plf 308 Plf ,7 Trapezoidal Loading Left LL TR1 112 Plf Left DL 68 Plf Riaht LL Riaht DL. Load Start Load End 112 Plf 68 PIt 0 Ft 24 Ft Riaht Cantilever 'Uniform Loading Live Load Dead Load Self Weiaht Total Load W 0 Plf 0 Plf 28 Plf 28 Plf Point Loading Live Load Dead Load P1 225 Lb 135 Lb Location 2 Ft '\ 1- ~ Roof Beamr 2003 International BuildinQ Code (01 NDS) 1 Ver: 6.00.7 By: Henry W. Gibson. Gibson Design Group on: 04-28-2005 : 11 :48:05 AM Project: ACHESON - Location: Beam 2 - Typical Header . Summary: 3.5 IN x 5.5 IN x 6.5 FT / #1 - DouQlas Fir-Larch - Dry Use Section Adequate By: 33.6% Controlling Factor: Section Modulus / Depth Required 4.76 In Deflections: Dead Load: Live Load: Total Load: Reactions (Each End): Live Load: Dead Load: Total Load: Bearing Length Required (Beam only, support capacity not checked): Beam Data: . Span: Maximum Unbraced Span: . Pitch Of Roof: Live Load Deflect. Criteria: Total Load Deflect. Criteria: Roof LoadinQ: Roof Live Load-Side One: Roof Dead Load-Side One: Tributary Width-Side One: Roof Live Load-Side Two: Roof Dead Load-Side Two: Tributary Width-Side Two: Roof Duration Factor: Beam. Self WeiQht: Slope/Pitch Adjusted LenQths and Loads: Adjusted Beam LenQth: Beam Uniform Live Load: Beam Uniform Dead Load: Total Uniform Load: Properties For: #1- DouQlas Fir-Larch BendinQ Stress: Shear Stress: Modulus of Elasticity: Stress Perpendicular to Grain: Adjusted Properties Fb' (Tension): Adjustment Factors: Cd=1.15 CI=1.00 Cf=1.30 DLD= LLD= TLD= LL-Rxn= DL-Rxn= TL-Rxn= BL= L= Lu= RP= U ! U LL1= DL1= TW1= LL2= DL2= TW2= Cd= BSW= Ladi= wL= wD adi= -wT= Fb= Fv= E= Fc_perp= Fb'= Fv': . Fv'= Adiustment Factors: Cd=1.15 Design ReQuirements: ControllinQ Moment: 3.25 ft from left support . Critical moment created by combining all dead and live loads. ControllinQ Shear: At a distance d from support. Critical shear created by combining all dead and live loads. Comparisons With ReQuired Sections: Section Modulus (Moment): Area (Shear): Moment of Inertia (Deflection): M= V= SreQ= S= AreQ= A= IreQ= 1= 0.06 0.09 0.15 609 401 1010 0.46 6.5 2.0 4 360 240 25.0 15.0 5.5 25.0 15.0 2.0 1.15 5 6.5 188 123 311 1000 180 1700000 625 1492 207 PSI IN IN = U855 IN = U516 LB LB LB IN FT FT : 12 PSF PSF FT PSF PSF FT PLF FT PLF PLF PLF PSI PSI PSI PSI PSI 1641 FT-LB 869 LB 13.20 IN3 17.65 IN3 6.29 IN2 19.25 IN2 22.59 IN4 48.53 IN4 ~ --,.. 8-~S 1*' Roof Beam[ 2003 International Building Code (01 NDS)] Ver: 6.00.7 By: Henry W. Gibson, Gibson Design Group on: 04-28-2005 Project: ACHESON - Location: Beam 2 - Typical Header Summary: 3.5 IN x 5.5 IN x 6.5 FT 1#1 - Douglas Fir-Larch - Dry Use Section Adequate By: 33.6% Controlling Factor: Section Modulus I Depth Required 4.76 In SHEAR, MOMENT, AND DEFLECTION DIAGRAMS Load combination shown: Controllin Shear/MomenUDeflection Dia rams 2000 1010 Ibs @ 0 ft 1000 Shear (Ibs) 0 -1000 -2000 2000 -1010 Ibs @ 6 ft k- 1641 ft-Ibs @ 3 ft 1000 Moment (ft-Ib) 0 -1000 -2000 -0.2 -0.1 Deflection (in) 0 0.1 0.2 10.151 in @ 3.2 ft Span = 6.5 ft Controllina Load Cases: Shear: Critical shear created by combining all dead and live loads. Moment: Critical moment created by combining all dead and live loads. Deflection: Critical deflection created by combining all dead and live loads. LOADING DIAGRAM 1 A I' w 1 B 'I , Span = 6.5 ft Reactions Live Load A 609 Lb B 609 Lb Dead Load Total Load Uplift Load 401 Lb 1010 Lb 0 Lb 401 Lb 1010 Lb 0 Lb Span Uniform Loading Live Load Dead Load Self Weiaht Total Load W 188 Plf 119 Plf 5 Plf 311 Plf I I 4/ / / / I I . I I I I I I I I I I I / I Prescriptive Approach - Simple Form For the Washington State Energy Code (2003 Edition) Climate Zone 1 Site Information RII"!!d. inf1npri~I-tITlPtit IIc::p()n1y... . ~-. '.~.:,=:J,'-:-'r!""".''''....-...~';-''_--:'''''~ ...~ ............1 . . Phone 2: 'PermiL#: . Lot: Address: /~/7 It/- /5"7lr~T~ City: ;!?OYZ.-T d7v~ State: Yt/4- Zip: f'?.3 ~ 3 Contact: /I-~I< ~~~ ~ Phone: "75"7- 9S-z...3 Fax: n UnIte azmg n hon ny Glazing Glazing U-Factor Door9 Wall Wall Wall Slab4 Option Area 10 U- Ceiling2 Vaulted Above Int4 Ext4 Floor5 On % of Floor Vertical Overhead]] factor Ceiling3 Grade Below Below Grade Grade Grade ill Unlimited Group R-3 DAD 0.58 0.20 R-38 R-30 R-21 R-21 R-I0 R-30 R-I0 Occupancy Only Table 6-1 PRESCRlPTIVE REQUIREMENTS 0,1 FOR GROUP R OCCUPANCY CLIMATE ZONE 1 (U r . d Gl . O' 0 1 ) See the code text for footnote references This project complies with the following: ..; The project is a single family residence or duplex. ..; The project is wood frame OR all of the insulation is interior or exterior of the framing. ,f All building components meet the requirements listed in Table 6-1, Option III. ,f The project will meet all other provisions of the WSEC and VIAQ. The project will take advantage of the following exceptions to the prescriptive option: o 602.6 Exception 1. One door, that is 24 ft.2 or less, that does not meet the standards is allowed. Location of the door taking this exception o 602.6 Exception 2. Doors with a U-factor of 0.40 allowed without calculations, Option III only. Location of the door(s) taking this exception Copyright 2002, WSUCEEP02-056 Copied by permission from the Washington State University Extension Energy Program Prescriptive - Simple Form - Climate Zone 1 7/26/2004 . CITY OF PORT ANGELES LIGHT DEPARTMENT 321 E. Fifth Street Port Angeles, WA 98362 (206) 457-0411 PERMIT NO ...!J ~ i' b 7-<;' ~ ~~ - ~ DATE Site Address: o READY FOR INSPECTION License Number: WI LL CALL FOR INSPECTION Phone: Installed By: Owner/Business: Phone: Owner/Business Address: Sq. Ft. Jf RESIDENTIAL o COMMERCIAL o BASEBOARD KW _ o FURNACE KW _ o FAN/WALL KW o HEAT PUMP KW o TEMPORARY SERVICE o PERMANENT SERVICE o NEW CONSTRUCTION o REMODEL l'r ADD/ALTER CIRCUITS o SERVICE UPGRADE/REPAIR o OVERHEAD SERVICE o UNDERGROUND SERVICE VOLTAGE: o SINGLE PHASE o THREE PHASE SERVICE SIZE AMPS o SIGN o SPECIAL EQUIPMENT (LIST BELOW) 1:!tiJi; ~~~I--N-f DetailslDescription: . W.S. No. SERVICE SIZE CAPACITY: o O.K. NOT O.K. ACTION REQUIRED: 0 CHANGE TRANSFORMER o INSTALL SERVICE POLE DATE ENGR. o CHANGE SERVICE WIRE o OTHER o Ditch Inspection O.K. ~ Rough-in/cover O.K. ~i{J O.K. to connect service ~Final O.K. Site Address: Installer: ~ Permit/Receipt No. .3~8b New Meters --. 7~~-9;J-. . Notify Port Angeles City Light by Street Address and Permit Number when ready for inspection. Work must not be covered before inspection and O.K. for covering has been given by the electrical inspector in writing on either the Wiring Report or on the Building ermi!. PHONE 457-0411, EXT. 224. ~ NO OCCUPANCY OR USE ESTABLISHED UNDER THIS PERMIT $ ;). (), {)o Permit Fee WHilE - File by address YELLOW - file by number PINK - Top: Eng, Bottom, Customer GREEN - Top: Meier Dept., Bottom: City Hall OLYMPIC PRINTERS INC. . Site Address: Installed By: Owner/Business: Owner/Business Address: ~ Residential ~ Heat KW /2..;:, ;;zl Baseboard 0 Furnace/Boiler b Heatpump 0 Other o Commercial/lndustrial load Total Connected load (attach breakdown) Total Motor load (attach breakdown) DetailslDescription: CITY OF PORT ANGELES LIGHT DEPARTMENT PERMIT NO. /o--5'7:? /,/ ~z $7 / / ELECTRICAL PERMIT DATE s~ G. o READY FOR INSPECTION License Number: ~ILL CALL FOR INSPECTION Phone: Phone: Sq. Ft. --0 New Construction 10 Remodel o Service update/alter/repair o Overhead o Undergr9un~ D Voltage /C;Z~ ~0 ~1.0 030 Service size ~ o Temporary Amps o Add/alter circuits o Auxiliary power (list below) o Special equipment (list below) 1) ~vJ !-0u...{, (. , ;J. S KuJ dk>C 60Mr) , . W,S. No, Service Size Capacity: 0 O.K, 0 Not O.K. Comments o Ditch inspection O.K. -1iJ~'f; Rough-in/cover O,K. 1e<"^:~ O.K. to connect service .~ Final O,K. It..- Notify the Department of City Light by Street Address and Permit Number when ready for inspection. Work must not be covered or electrically energized before inspection and O,K. for covering or service has been given by the Inspector in Writing on the Wiring Report or the Building Permit. PHONE 457.0411, EXT. 158 or EXT. 224. :3D~ Site Address: 15~ . Date Hold for: 0 Easement 0 Letter o Signed up for service/meter o Meter Department notified for installation o Fire Department notified of inspection o Plan Review approved/pending Permit/Receipt No. New Meters o NO OCCUPANCY OR USE ESTABLISHED UNDER THIS PERMIT T~ Inspector WHITE - file by address YELLOW - file by number Amount paid PINK - Top: Eng, Bottom: Customer GREEN - Top: Inspector, Bottom: City Hall OLY,,",PIC PRINTERS. INC. . CITY OF PORT ANGELES LIGHT DEPARTMENT PERMIT NO. 13 !;5 7/2-0/ /17 ELECTRICAL PERMIT DATE a ) D READY FOR INSPECTION License Numbe/~..t23 D WILL CALL FOR INSPECTION Site Address: Installed By: Phone: Owner/Business Address: Sq. Ft. o Residential Heat KW o Baseboard 0 Furnace/Boiler o Heatpump 0 Other o Commerciai/lndustriai load Total Connected load (attach breakdown) Total Motor load (attach breakdown) o New Construction o Remodel o Service update/alter/repair o Overhead o Underground Voltage 010 03.0 Servi~size ~mporary o Add/alter circuits o Auxiliary power (list below) o Special equipment (list below) Amps Detai I slDescri ption: . W.S. No. Service Capacity: 0 O.K. 0 Not O.K. o Ditch inspection O.K. o Rough-in/cover O.K. ru--~.K. to connect service o Final O.K. Size Comments. Date Hold for: 0 Easement 0 Letter o Signed up for service/meter o Meter Department notified for installation o Fire Department notified of inspection o Plan Review approved/pending Installer: /~ I Site Address: . Notify the Department of City Light by Street Address and Permit Number when ready for inspection. Work must not be covered or electrically energized before inspection and O.K. for covering or service has been given by the Inspect 'n iting on the Wiring Report or the Building Permit. PHONE 457.0411, EXT. 158 or EXT. 224. /~~ In p etar I Amount paid WHITE - file by address YELLOW - file by number PINK - Top: Eng, Bottom: Customer GREEN - Top: Inspector, Bottom: City Hall NO OCCUPANCY OR USE ESTABLISHED UNDER THIS PERMIT OLYMPIC PRINTERS, INC.