Loading...
HomeMy WebLinkAbout1622 Milwaukee Dr - Building $~ Y!I! CITY OF PORT ANGELES PUBLIC WORKS - ELECTRICAL DIVISION :m EAST 5TH STREET. PORT ANGELES. WA 9l\:l62 Application Number Application pin number property Address ASSESSOR PARCEL NUMBER: Application type description subdivision Name Property Use property Zoning . . . Application valuation 05-00000661 Date 12/30/05 497364 1622 MILWAUKEE DR 06_30_00_9_9_0140-0000- RES REMODEL RS9 RESDNTL SINGLE FAMILY 6500 Contractor Owner ------------------------ ------------------------ OWNER BRASTAD ANDREW piC M 1622 MILWAUKEE DR PORT ANGELES WA 983631104 ---------------------------------------------------------------------------- Permit . . . . . Additional desc . Permit pin number Permit Fee Issue Date Expiration Date ELECTRICAL ALTER RESIDENTIAL OWNER/ BATH-MASTER BEDRM. 67751 48.10 12/30/05 6/28/06 Plan Check Fee valuation .00 o "- ~ \J 7V ---------------------------------------------------------------------------- Qty 1. 00 Unit Charge Per 48.1000 ECH EL-R OR RM 1-4 ALT CIRCUITS Extension 48.10 Special Notes and Comments The Fire Department has reviewed the project application and has no comments 08/10/2005 09:57 AM SROBERDS - The proposal will result in an addition to a s.f. res in the RS-9 for total lot coverage of 7%. No land use issues are noted. Electrical load calculations and elctrical permits are required ." Public Works Utility Engineering has no requirements for this plan review. ~ .... ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE SURCHARGE 4.50 (' t ~ ;;. 1\ ~ ~ ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 48.10 48.10 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 4.50 4.50 .00 .00 Grand Total 52.60 52.60 .00 .00 tJ ~ CO~1MENTS/ ACTION NEEDED ELECfRICAL PERMIT INSPECfION RECORD CALL 417-4735 FOR ELECTRICAL INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLA WFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE IT IS INSPECTED AND ACCEPTED. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE COMMENTS NO I 3-,ol:~ GENERAL COMMENTS: PW -1102.1 ~ (-4196] $ l.~ -~'.; "t- ':$>'" ""'... ELECTRICAL WORK PERMIT APPLICATI(~/ 04 License number Date Expires Installation description o Commercial y('ReSidential o New J(Altered/Addition Job wired by o Electrical Contractor ~wner City State ZIP Ih4 ~_ t-!ft1--/k,rl~ ~} ~~~ / /J -~'~{7~ ( f (j , ALd::r. .. Telephone number FAX number , '. Premises owner's name L.j IJndv B (tL5"@._ Address of4nspect~.. ... . \ I!J? ~if-:' /u:;,Xwa.wke-e.:.:.JJG,"ve C', / _ q I Y'Pt7(71Jn~{/) r uJ~. t3~3 " Phone number 0 s~~le ins ~n:d2- t.f/ 7-;).'1/51 WOY'/..L) Owner as dejine.d by RCW19.:!8.261:(J) Owner will occupy the structure for two years after this eleCtrical permit isfina/ized, (2) Owner is required to hire an electrical contrapor if above said property is for sale, rent or lease. After reading the above statement, I hereby certify that I am the owner of the above named p~~perty or a licensed electrical contractor. 1 am making the electrical instal- lation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296-468, The City of Port Angeles Municipal Code, and Utility Specifications. < o Cash 0 Check # o Credit Card Card # Visa Mastercard Discover x Date: Expiration Date of card '.' Electrical Load Additions and or subtractions IJ NO LOAD CHANGES Cl Baseboard KW o Furnace KW o Heat Pump _ Ton )(Fan-ivall I ~ KW SAME DAY INSPECTION, CALL BEFORE 7:00 AM 360-417-4735 Service Information LAR o Overhead Service o Temp Service o Underground Service Voltage :;l.;;J..O PhaseA!f 1 IJ 3 Service Size: ~ ""..p Feeder Size: .y. " ROUGH-IN " / THERMOSTAT SERVICE 1~!:5 d!(!, "- Dale Approved By Dale Approved By FINAL "- / DITCH FEEDER 54~6 A-&2 '-! lIle ApprovedBy../ "- Dale Approved By ../ Date Approved By Inspection Area, Building or Equipment Inspected Action Taken Electrical Date Inspector . . -, . ~ ,- -- \ ,- ' .. ~ - , , Af)"/:<- VA~ )D<:"' , / '0, 16'-011 'I ~~ , N^ILED TO 5^Mt. ~ I UV r.:::;J EXISTING SHEETING.) . CS-20 STMrflNG MIN. 9" E!.CH W^LL (NEW <I. OLD) - 5'-0" T'-BlI" , ----r-- " 60W 3' 0" i 3'-~1/Z" F 5'-0" ~ 4'-0"_ 306B 5040 XO 5f!>Wf' &,1 :;l;c.I'~j 8\"1~do.'" I I , >- I~ :; \!l C Z ;:~ Ia:, i= \!)e <fl !\?\ 1;1 zu - ( I- .. l~ ~ ~~ tj= 'r < 0 o. "1 ... 1-, :S z, 0' ~ I- 13. - <fl to => OJ' :=; <fl to \!l -' , -' ~ Z\!l < ~ \b -z 3: :1:_ , 3:=; in I~ :I:~ Z I ~ LL tl.." --' < in--' "" I <""I- .J z3:0<fl \ 0 , .~ N MASTER BDRM \ ---71------------ / I" ~ 8' ~ /" to\.- ~ I " ~. // I "T1 ! " . T I l- - 21-8" I " ~ " to d..ODr- I ~ I ~"1 I l() L C.\o::><.t \ <;1 0 o I ~ I I I , 31/8 X 10 1/2 24f-V4 GLULAM f!>EAM G G I ~'l ~ to, ~ ~ 1 y I l ~ I ; I ~ \!) I ' in I I "r -- '" j_: 7-6" J~o....... JC +- <5 en 2'- ,<,>" ~ ~ M"".,h. I(,,,,~\-.- aD o , ({) ~ .' MAIN FLOOR PLAN 1/411 = 1', I CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY DEVELOPMENT - BUILDING DNISION 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Application Number Application pin number property Address ASSESSOR PARCEL NUMBER: Application type description subdivision Name Property Use Property Zoning . . . Application valuation 05-00000661 Date 497364 1622 MILWAUKEE DR 06-30-00-9-9-0140-0000- RES REMODEL 8/22/05 -- Owner Contractor F/tJlI[(fO ~/O0 P0 t;" ~ RS9 RESDNTL SINGLE FAMILY 6500 BRAS TAD ANDREW pic M 1622 MILWAUKEE DR PORT ANGELES WA 983631104 OWNER 3' r ( ~ 7' P 0' ('J Permit BUILDING PERMIT -RESIDENTIAL Additional desc ENLARGE BEDROOM Permit pin number 57398 Permit Fee 162.75 Plan Check Fee 65.10 Issue Date 8/22/05 Valuation 6500 Expiration Date 2/18/06 Qty Unit Charge Per Extension BASE FEE 92.75 5.00 14 . 0000 THOU BL-2001-25K (14 PER K) 70.00 permi t . . . . . Add~tional desc . Permit pin number Permit Fee Issue Date Expiration Date MECHANICAL PERMIT 57406 54.25 Plan Check Fee 8/22/05 Valuation 2/18/06 .00 o Qty Unit Charge Per Extension 47.00 7.25 BASE FEE 1.00 7.2500 ECH ME-VENT FAN Permit . . . .. PLUMBING PERMIT Additional, desc . Permit pin number 57414 Permit Fee 68.00 Plan Check Fee. . .00 Issue Date . \. .. 8/22/05 Valuation 0 Expiration Dat\. 2/18/06 Qty Unit Charge Per Extension BASE FEE 47.00 3.00 .0000 ECH PL- EA.FIXTURE ON ONE TRAP 21.00 ---------------------------------------------------------------------------- Special Notes and Comments The Fire Department has reviewed the project application and has no comments 08/10/2005 09:57 AM SROBERDS - The proposal will result in an addition to a s.f. res in the RS-9 for total lot coverage of 7%. No land use issues are noted. Electrical load calculations and elctrical permits are required. public works Utility Engineering has no requirements for Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authonzed IS not commenced within 180 days, if construction or work is suspended or abandoned for a penod of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last inspection I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authonty to violate or cancel the provisions of any state or local law regulating construction or the performance of constructIOn. Signature of Contractor or Authorized Agent Date Signature of Owner (If owner is builder) T.\Pol1cles\1102_15 bUlldmgpermlt mspectlOn record05 wpd [1/4/2005] CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY DEVELOPMENT - BUILDING DNISION 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Application Number . . . . . 05-00000661 Application pin number 497364 Page 2 Date 8/22/05 Special Notes and Comments this plan review. Other Fees STATE SURCHARGE 4.50 Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 285.00 285.00 .00 .00 Plan Check Total 65.10 65.10 .00 .00 Other Fee Total 4.50 4.50 .00 .00 Grand Total 354.60 354.60 .00 .00 Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized IS not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authonty to violate or cancel the provisions of any state or local law regulating construction or the performance of construction Signature of Contractor or Authorized Agent Date Signature of Owner (If owner is builder) Date T \Pohcles\1102_15 bUlldmgpenmt mspectlOn record05 wpd [1/4/2005] BillLDING PERMIT INSPECTION RECORD 05 -tP~ J CALL 417-4815 FOR BUILDING INSPECTIONS CALL 417-4735 FOR ELECTRICAL INSPECTIONS. CALL 417 -4807 FOR PUBLIC WORKS UTILITIES PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED COMMENTS YES NO FOUNDATION: FOOTINGS r I WALLS '/4-)0(, Jvv FOUNDATION DRAINAGE 1 DOWN SPOUTS I PIERS POST HOLES (POLE BLDGS.) II n-Ib-OL~ ci.L.y PLUMBING f"nu/</ UNDER FLOOR 1 SLAB ROUGH-IN V) ~~.f,p. vW I 6;b;O~ f'b WATER LINE (METER TO BLDG) GAS LINE BACK FLOW 1 WATER AIR SEAL WALLS ( .'14~L<fbt,~ CEILING I FRAMING JOISTS 1 GIRDERS SHEAR WALL/HOLD DOWNS 111- '1 -OS .,J ,... V WALLS 1 ROOF 1 CEILING r - DRYW ALL (INTERIOR BRACED PANEL ONLY) T.BAR INSULATION SLAB WALL 1 FLOOR 1 CEILING I liS-to" ..::JW I . MECHANICAL HEAT PUWWI FURNACE 1 DUCTS A~ GAS LINE WOOD STOVE 1 PELLET 1 CHIMNEY b;il<% ~J';J COMMERCIAL HOOD 1 DUCTS MANUFACTURED HOMES FOOTING 1 SLAB BLOCKING & HOLD DOWNS SKlRTING PLANNING DEPT SEPARATE PERMIT #'s SEPA P ARKINGILIGHTlNG ESA LANDSCAPING SHORELINE FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCYIUSE RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED YES NO ELECTRICAL - LIGHT DEPT 4 I 7-4735 ELECTRICAL LIGHT DEPT CONSTRUCTION R W 1 PWI CONSTRUCTION - R.W ENGINEERING 417-4807 PW 1 ENGINEERING FIRE 417-4653 FIRE DEPT PLANNING DEPT 417-4750 , /, / PLANNING DEPT BUILDING 417-4815 tJ/~/("V 'fVP BUILDING T \Pohcles\1102_15 bUlldmg permit mspectlOn record05 wpd [1/4/2005] PREPARED 6/06/06, 8:59 17 CITY OF PORT ANGELES ADDRESS CONTRACTOR OWNER PARCEL APPL NUMBER. INSPECTION TICKET INSPECTOR JAMES L LIERLY PAGE DATE 6 6/06/06 1622 MILWAUKEE DR 01 10/18/05 10/18/05 SUBDIV: PHONE PHONE : BRASTAD ANDREW pic M 06-30-00-9-9-0140-0000- 05-00000661 RES REMODEL PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BUILDING POST/COLUMN FTG TIME. 17:00 10/17/2005 08 55 AM PBARTHOL ---------------------------ANDY INSPECTION REQUEST AFTER 10:00 AM 10/17/2005 09 48 AM PBARTHOL --------------------------- 10/19/2005 08 11 AM PBARTHOL --------------------------- BUILDING SHEARWALL 10/27/2005 08 25 AM PBARTHOL --------------------------- ANDY 452-3493 10/28/2005 04 45 PM JLIERLY ---------------------------- add na11s 1nto beam 4" ocIJ11 BUILDING SHEARWALL TIME. 17:00 11/07/2005 08.53 AM PBARTHOL --------------------------- ANDY 452-3493 11/08/2005 08:36 AM JLIERLY ---------------------------- BUILDING AIR SEAL 01/04/2006 04:35 PM JLIERLY ---------------------------- 01/04/2006 04:41 PM JLIERLY ---------------------------- BUILDING FRAMING 01/04/2006 03:32 PM DYASUMUR --------------------------- ANDY PH. 452 3493 REQUEST FRAMING AND PLUMBING INSPECTIONS 01/04/2006 04.31 PM JLIERLY ---------------------------- BUILDING INSULATION * OVERRIDE TAKEN BY DYASUMUR DATE: 01/05/06 TIME. 07.51:03 01/05/2006 07:50 AM DYASUMUR --------------------------- ANDY PH 452-3493 AFTERNOON INSPECTION 01/05/2006 04:58 PM JLIERLY ---------------------------- BL99 01 ~/ 6/0 ~LL BUILDING FINAL TIME 13:00 ANDY 452-3493 06/05/2006 10 13 AM DYASUMUR --------------------------- ----------- - -------------------------------------------------------------------------------- BL6 BL9 BL9 BAIR 01 BL3 BLI 01 10/28/05 10/28/05 JLL AP JLL DA JLL AP JLL AP JLL AP JLL AP 458-3493 TUE AM PERMIT: ME 00 MECHANICAL PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ME99 01 02 11/07/05 11/08/05 ______~___~~~~~~~~~~~~~~~~~~I~~=;~::~:__~__::~:~___________________ PERMIT: PL 00 PLUMBING PERMIT R QUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS PL2 1/04/06 1/04/06 01 1/04/06 1/04/06 JLL AP PLUMBING ROUGH-IN 01/04/2006 11 35 ANDY 452-3493 01/04/2006 04 32 PM JLIERLY ---------------------------- PL99 01 -Tiji/06 06 JLL PLUMBING FINAL TIME. 13:00 ~ ANDY 452-3493 06/05/2006 10:15 AM DYASUMUR ------------ -------------------~~~~~~-~~~~~~:-~~-~~~~:-~------------------------------------- 01 1/05/06 1/05/06 01 1/04/06 1/04/06 TIME: 17 00 AM DYASUMUR --------------------------- PREPARED 1/05/06, 13 08 28 CITY OF PORT ANGELES ADDRESS CONTRACTOR OWNER PARCEL APPL NUMBER: 1622 MILWAUKEE DR BRASTAD ANDREW PiC M 06-30-00-9-9-0140-0000- 05-00000661 RES REMODEL INSPECTION TICKET INSPECTOR JAMES L LIERLY PAGE DATE 1 1/05/06 SUBDIV: PHONE PHONE PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL6 01 10/18/05 10/18/05 JLL AP BL9 01 10/28/05 JLL 10/28/05 DA BL9 02 11/07/05 JLL 11/08/05 AP BAIR 01 1/04/06 JLL 1/04/06 AP BL3 01 1/04/06 JLL 1/04/06 AP BLI 01 ~ JLL ~ BUILDING POST/COLUMN FTG TIME 17 00 10/17/2005 08 55 AM PBARTHOL ---------------------------ANDY 458-3493 TUE AM INSPECTION REQUEST AFTER 10 00 AM 10/17/2005 09 48 AM PBARTHOL --------------------------- 10/19/2005 08 11 AM PBARTHOL --------------------------- BUILDING SHEARWALL 10/27/2005 08 25 AM PBARTHOL --------------------------- ANDY 452-3493 10/28/2005 04 45 PM JLIERLY ---------------------------- add na11s 1nte beam 4" ec/]ll BUILDING SHEARWALL TIME 17 00 11/07/2005 08 53 AM PBARTHOL --------------------------- ANDY 452-3493 11/08/2005 08 36 AM JLIERLY ---------------------------- BUILDING AIR SEAL 01/04/2006 04.35 PM JLIERLY ---------------------------- 01/04/2006 04 41 PM JLIERLY ---------------------------- BUILDING FRAMING 01/04/2006 03.32 PM DYASUMUR --------------------------- ANDY PH 452 3493 REQUEST FRAMING AND PLUMBING INSPECTIONS. 01/04/2006 04:31 PM JLIERLY ---------------------------- BUILDING INSULATION * OVERRIDE TAKEN BY DYASUMUR DATE' 01/05/06 TIME: 07:51 03 01/05/2006 07:50 AM DYASUMUR --------------------------- ANDY PH 452-3493 AFTERNOON INSPECTION -------------------------------------- COMMENTS AND NOTES -------------------------------------- rpe> l 'r " A ~cM-. ~,~ b \J tr"i\.- :I:N. <;. c.) \ . PREPARED 1/04/06, 13 30 22 CITY OF PORT ANGELES ADDRESS CONTRACTOR OWNER PARCEL APPL NUMBER 1622 MILWAUKEE DR BRASTAD ANDREW pic M 06-30-00-9-9-0140-0000- 05-00000661 RES REMODEL INSPECTION TICKET INSPECTOR: JAMES L LIERLY PAGE DATE 5 1/04/06 SUBDIV PHONE PHONE PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL6 01 10/18/05 10/18/05 JLL AP BL9 01 10/28/05 JLL 10/28/05 DA BL9 02 11/07/05 JLL 11/08/05 AP BL3 01 ~~ BUILDING POST/COLUMN FTG TIME. 17 00 10/17/2005 08.55 AM PBARTHOL ---------------------------ANDY 458-3493 TUE AM INSPECTION REQUEST AFTER 10 00 AM 10/17/2005 09.48 AM PBARTHOL --------------------------- 10/19/2005 08:11 AM PBARTHOL --------------------------- BUILDING SHEARWALL 10/27/2005 08.25 AM PBARTHOL --------------------------- ANDY 452-3493 10/28/2005 04.45 PM JLIERLY ---------------------------- add nalls lnte beam 4" ec/]ll BUILDING SHEARWALL TIME 17 00 11/07/2005 08 53 AM PBARTHOL --------------------------- ANDY 452-3493 11/08/2005 08 36 AM JLIERLY ---------------------------- BUILDING FRAMING 01/04/2006 03 32 PM DYASUMUR --------------------------- ANDY PH 452 3493 REQUEST FRAMING AND PLUMBING INSPECTIONS. PERMIT: PL 00 PLUMBING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS PL2 $~ 01 PLUMBING ROUGH-IN TIME 17 00 01/04/2006 11.35 AM DYASUMUR --------------------------- ANDY 452-3493 -------------------------------------- COMMENTS AND NOTES -------------------------------------- '[<{[al<' ~ ~(L- ~( PREPARED 11/07/05, 10 59.51 CITY OF PORT ANGELES ADDRESS CONTRACTOR OWNER PARCEL APPL NUMBER 1622 MILWAUKEE DR INSPECTION TICKET INSPECTOR JAMES L LIERLY PAGE DATE 5 11/07/05 BRASTAD ANDREW piC M 06-30-00-9-9-0140-0000- 05-00000661 RES REMODEL SUBDIV PHONE PHONE PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL6 10/18/05 JLL 10/18/05 AP 01 BL9 10/28/05 JLL 10/28/05 DA 01 BL9 ~~ 02 BUILDING POST/COLUMN FTG TIME 17.00 10/17/2005 08 55 AM PBARTHOL ---------------------------ANDY 458-3493 TUE AM INSPECTION REQUEST AFTER 10 00 AM 10/17/2005 09 48 AM PBARTHOL --------------------------- 10/19/2005 08 11 AM PBARTHOL --------------------------- BUILDING SHEARWALL 10/27/2005 08 25 AM PBARTHOL --------------------------- ANDY 452-3493 10/28/2005 04 45 PM JLIERLY ---------------------------- add oalls lote beam 4" ee/)ll BUILDING SHEARWALL TIME 17 00 11/07/2005 08 53 AM PBARTHOL --------------------------- ANDY 452-3493 -------------------------------------- COMMENTS AND NOTES -------------------------------------- PREPARED 10/28/05, 12 59 07 CITY OF PORT ANGELES INSPECTION TICKET INSPECTOR. JAMES L LIERLY PAGE DATE 5 10/28/05 ADDRESS CONTRACTOR OWNER PARCEL APPL NUMBER 1622 MILWAUKEE DR SUBDIV PHONE PHONE BRASTAD ANDREW PiC M 06-30-00-9-9-0140-0000- 05-00000661 RES REMODEL PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL6 01 10/18/05 JLL 10/18/05 AP BUILDING POST/COLUMN FTG TIME: 17.00 10/17/2005 08 55 AM PBARTHOL ---------------------------ANDY 458-3493 TUE AM INSPECTION REQUEST AFTER 10:00 AM 10/17/2005 09 48 AM PBARTHOL --------------------------- 10/19/2005 08 11 AM PBARTHOL --------------------------- BUILDING SHEARWALL 10/27/2005 08 25 AM PBARTHOL --------------------------- ANDY 452-3493 BL9 01 ~~~JSLA -------------------------------------- COMMENTS AND NOTES -------------------------------------- ~ ~\s k:. ~ PREPARED 10/18/05, 13:48:08 CITY OF PORT ANGELES INSPECTION TICKET INSPECTOR JAMES L LIERLY PAGE DATE 9 10/18/05 ADDRESS CONTRACTOR OWNER PARCEL _ _ APPL NUMBER 1622 MILWAUKEE DR SUBDIV- PHONE PHONE - BRASTAD ANDREW piC M 06-30-00-9-9-0140-0000- 05-00000661 RES REMODEL PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL6 "' /o/ifdf7{J- BUILDING POST/COLUMN FTG TIME 17:00 10/17/2005 08-55 AM PBARTHOL ---------------------------ANDY 458-3493 TUE AM INSPECTION REQUEST AFTER 10 00 AM 10/17/2005 09:48 AM PBARTHOL --------------------------- -------------------------------------- COMMENTS AND NOTES -------------------------------------- BUILDING PERMIT - APPL!CATION www cltyofpa us Print out form and fill out COMPLETEL Y in INK. Your application and site plan MUST BE COMPLETE to be accepted for review. Questions? Call: PERMITS (360) 417-4815 Fax (360) 417-4711 Dale Approved Date Issued ApplIcant or Agent: And r e \.;{) '"B r-~.)4-~d Owner:~ drG-l-0 brc.s\-eo.d Address: 1&2 2 ;t1 (I WC<v{ Ke-<... CIty. Por~ AnJ cA< ~ Architect/Engineer: E \/ e S .{-DVl e.. / U '\j L-'- , / State License #: 452.-3L.iC1.3 Phone: 3 C?b - ~ Phone Zip: q 8.3 "'.3 Phone: Contractor Exp: Phone: Address: City: PROJECT ADDRESS: 1& 2 2. JVl; I w ~ tA k e -<- b r; V c. LEGAL DESCRIPTION: Lot: .1'1 Block: SubdivisIOn: Dc. ea V\ CLALLAM COUNTY PARCEL NUMBER: D (0.3 00 0 C} '1 0 { '" 0 Zip: ZONING: VIGt.J t<;: ~l-c,... ~~;i~i~ ~~~~=::ldi{;2~ ~ ~f~.)e~~~ k e ~~S-\-~C~ity: Credit Card Type VISA~MC # TYPE OF WORK: SIZENALUATION: o ResIdential 0 }/ew Constr 0 Re-roof 0 Stove SF @ $ o MultI-famIly rnI' AdditIOn 0 Move 0 Garage SF @ $ o CommercIal 0 Remodel 0 DemolItIOn 0 Deck SF. @ $ o RepaIr 0 Sign 0 Other TOTAL VALUATION BRIEF DESCRIPTION OF THE PROJECT. el/"\ k.r::j -f.' b<ldr{)d ,'1/\ PA- Exp. Date: (" /SF = $ /SF = $ /SF. = $ $ 0.:f"OD I COMMERCIAL/RESIDENTIAL: Occupancy Group -8. -") No of Stones 1- Lot Size t g'l95'L EXistIng Sq Ft 10'13 Total lot coverage Occupant Load & Proposed Sq % .'01 -I' Construction Type Ft/q Z-. = TOT AL Sq Ft II J> ::;--- , . I APPROV ALS: PLAN: BLDG: DPWU: FIRE: OTHER: PLANNING USE ONLY: J?:SA/Wetland(s) 0 Yes 0 No SEPA ChecklIst reqUIred? 0 Yes 0 No Other. BUILDING PERMIT APPLICA TION SUBMITT AL: The BUIldIng DIVISion can prOVide you WIth InformatIOn on the applIcatIOn and plan submIttal reqUIrements If you have questIOns V ALUA TION OF CONSTRUCTION In all cases, a valuation amount must be entered by the applIcant ThiS figure wIll be reViewed and may be revised by the BUIldIng DIVISIOn to comply WIth current fee schedules Contact the PermIt CoordInator at 417-4815 for assistance PLAN CHECK FEE. IF a pl ck fee IS due It must be submitted at the time the bUIldIng permit applIcation and constructIOn plans are submitted All other permit fees are due at the time of permIt Issuance EXPIRATION OF PLAN REVIEW: Ifno permit IS Issued WithIn 180 days of the date of applIcatIOn, the application will expire. The BUIldIng OffiCial can extend the tIme for actIOn by the applIcant up to 180 days upon wntten request by the applIcant (see SectIOn R 10532 of the InternatIOnal BUIldIng/ReSidential Code, 2003) No applIcatIOn can be extended more than once I hereby certify that I have read and exammed thiS applicatIOn and know the same to be true and correct I am authonzed to apply for thiS permit and understand that It IS my responSibility to determme what permils are reqUired, not the Cily's, and that I must obtam such permils pnor to work wwwcltyofpaus APPlIcan~aJaA- Date .:fulr {~'05 ho,-<s<.. ~ 52 fr.x 2.c",ff- = (3523, FI- J'1FI- (0 cJZ;: (f--:::; .2. 2.- Pr- )( l ( r:; t' -::- LJ lo 7- '-h~\ -=- \~ I ~ 5'1 F+ ~ Prescriptive Approach - Simple Form For the Washington State Energy Code (2003 Edition) Climate Zone 1 Site Information Ol9 ?f.-"OO CJ ('\ c 1l..4 (;. Lot: ) 4 0 c..~L\ h\/,,.e,,~.) E. 5 h ~e..> Address Il.., L 2.. M . l U..X'lL-\ (Leo t... -0 r City Po (~l- A. D e...l e. ~ State' WA Zip q [3(..;.5 Contact A ~'\c\ \1 "\)c<;,s h" q I Phone (/-I) L/ Sl- 3 LfCj 3 Phone 2L vV) Y I 7 - 2.. t...f 1::;- Building Department Use Only Permit #. Notes. ,lr'l " , o,="'::,h , "c' .. _d~' 1- " ,>_< Fax. - >" ' l' , l)_ ,'>, ',11 , I _ , .~, '";'1 1 _', > 'L':, _ .. '" ',," 0'" ',.1 ,'.<. :,,-,! .- ..- ,,__ _<,~ _, ~,':O r ;: ~.' ; ,'f' > ~;;: ,-" '"r_ p ",-t ' i', _!t n,'" n IllIte azmg tIon ny Glazmg Glazmg U-Factor Door9 Wall Wall Wall Slab4 OptIon Area 10 U- Ceilmg2 Vaulted Above Int4 Ext4 Floors On % of Floor Vertical Overhead 11 factor Ceiling3 Grade Below Below Grade Grade Grade ill UnlimIted Group R-3 040 058 0.20 R-38 R-30 R-21 R-21 R-l0 R-30 R-l0 Occupancy Only Table 6-1 PRESCRIPTIVE REQUIREMENTS 0,1 FOR GROUP R OCCUPANCY CLIMATE ZONE 1 (Ur dGl' O' 01) See the code text for footnote references This project complies with the following: ./ The project is a single family reSidence or duplex ./ The project IS wood frame OR all of the Insulation is intenor or extenor of the framing ./ All bUilding components meet the requirements listed in Table 6-1, Option III ./ The project Will meet all other provISions of the WSEC and VIAQ The project will take advantage of the following exceptions to the prescriptive option. ~ 602 6 Exception 1 One door, that IS 24 ft 2 or less, that does not meet the standards IS allowed Location of the door taking thiS exception AJ /) r-t ~ claar . o 6026 Exception 2 Doors With a U-factor of 0 40 allowed without calculations, Option III only Location of the door(s) taking thiS exception . T'/pE:.. D F l-\GAt SO"'i2.c...p'? \" " I' v ~ \~,~<. '<.~ C.;...l y- Copynght 2002, WSUCEEP02-056 Copied by permission from the Washington State University ExtenSion Energy Program Prescriptive - Simple Form - Climate Zone 1 7/26/2004 : t"J,>'~ ;_. .:~ ;~~~'~." ... '-:., .'~', ~,:.~:. :~~ J: /~:~~ ~~~:~-';-~~; ~: l:~., Gene H. Unger · Engineering, Inc. 30 October 2003 Civil · Structural · Management 1401 West 7th Street Port Angeles. Washington 98363 Office (360) 452-2098 Fax (360) 417-2098 E-mail: ungerpe@olypen.com Andrew Brastad 1622 Milwaukee Drive Port Angeles, W A 98363 Subject: Engineeril')g on proposed addition. ',.~- (, .-- ,.; -..~ 6ear Mr. Brastad: , , ._~:. ~ ~ .-! t. I ',.J '.. Enclosed please find one copy of the engineering for your proposed addition. Paul Eyestone received copies for permit. I am sorry for taking so long to forward this to you. I am also enclosing an invoice for this work. Thank you for using Gene Unger Engineer, INC. for this work. Sincerely, p~ fct ,;f~/CA~ Gene H. Unger, PE . /' - ~ INC.: Engineering Invoice , ' ./. , . " .....' '1,1, -~'" . . ., ~ ~ \ ~ >" I.... .. , ' '" ";. - -' I 03037B1.doc 1 Gene Unger Engineering, Inc. 1401 W. 7th Street Port Angeles, W A 98363 BILL TO Eyestone-Brastad; 03037 DATE 10/23/2003 Invoice INVOICE # 2003127 DESCRIPTION AMOUNT 4 Jun. Engr on addition 172 50 6 Jun Engr additIOn & deliver 14250 ~\\> '\ \(D~ " I Thank you for your busmess. I Total $315 00 1_ _ . ___ __...~ __ __________J F'r.L ~ -f. tf) #'I of? - t ~".F r",,( G, rI, t/,. H Vv/-Hi' '03 ____ _______ ___ p ~ t? 3 '7 t I -----.... If? w",~ .' Ir();~c t/ ~ tJ ~~ '? J1 ~ E""'1Y' A~)/('tU tJ;a~t-e:r e:/ It 2..2., fV1, )WCl ~ f....e tJ r, /tf/{; /In? e r~C;, wA 10> b Z E'#c I~~':"f C.P"'"~ z. ~,/ F/~d y, CtJ 1I.e-v~d '::""I''--'''~_ 6e I,IA/, Ere 5-1 &JH-e ~ Ie/ '7, h.~,~., 'ZI> 5, L,"coll-f #:2.6 ) 10 r -r A HI' -e I't' oS J w,If 9 tB -:> If ?- ~.:) 7 - J# / tJ 6<A1~ )-1 . tt", r ~ y' ) JI d I W, 7 -r-J., ~",.1; ~I't Y ~ /~~" w.l} 9036"3 :3 tf I) - 4'>2.. - "2-1J 'I B I I 11 I I I r EXPIRES, "3 ~/7- d ~ j :3& C!J;{) d '"7 E"y~ ~ f-~..Q - grtllf5>'/-""',1: 6-, /-I. 14, I I 4 JUA?e' C)J 7' z.. Co-rl eI, r;:n.,J ~ I<:J 9 7 v< A t::: W/~~,' fp P1/h &1' /1 // ~ I I i I ! I I I i I .5 -e; ~ ",.. ; c: :::z I!rH ~ " " ;:1 5,; / ~-E>~"'; V1 / : " IS-t)O It. -r . vV I; c1 , Ce.== /" 0, 7~ I I' r/~ .p ::2-' cr -:=::- ~G' Jr) "v.t 1/ 6.:; ~tAr w" II ~/ 9 ,y.;;t;" /t7,,-(- NI}f~"",,-/ t?/ 3'- I "7 rod f (p. &1d ".u_.1 iJ.,,,:?V<O }"lYtlf )~<vV~,' 'l-~ -=- /6/ If /_rf rw -:::-- I. D PvV-C~C'1 '1> r.N~- 617(bf8+~,.~~/6'f/::= /tl/crlS>J fr - t:l ,. 7 (IY, 7 J.. o.,j') /6. 'I:::: II,? I 9--r : EY<$-r,#'1~ - Blco,.f;c,/ ~,f1,V, J-I J~"t!! ' ~::z ~~C 7' 1.3' I I I. La-r~ot/ N-;; ~ /0/, 9 [~(J-18)' ~J-t- :a- If -= PI) =- /I,f [~(~51 - 1-9&0 .J- 11./ 7 :;;- 1?O~ Jb~ , PI - p.z... ~ /'1.1 [~{lfBD :::.. J Fag .1- 572- 2- '1'2- 2- Cf / by , ,ocf- -1- $1.,,, jV!"'f.;,::- Z6 ( qg) (7 t- B) + p.t-f~g)z (;7) 6 I ~ 7'].--0 ..J.- I:>O?b --- ~7 g 1 b rg - /Cl (if;7 Ib 7/ Gd v~ Y/ $ . Wr- - /--{; -Fz;- ~ = - w"\/ - -;]......6 ;Fl7 /.w ~ lib- It) /efF jcr>fJlr 0 - - :::...- "?-("2-6) 5/er.A1 ,( er" d vVlttl ~ 11 ~~-t., l' tf)( . ~ . Ey-e ~ t-<P7"r-c. - J"'(J(,Pf."J L/ J_~ 'd:z /) :J t:J ~ ~HtU, ,/.q~..J : FtPf >tr - u/~ Co r F -= 1014F W A' ~ '7 7, 5' -I- It.::: .It 9;J -F'C7 ' W.s::::: qg,..~- b -6 = ~ '" ,>- ~v ' ~N~ 117 r4 },- ~J"3' 7') J~'>IIj- If r;. == It) , 4- '7- ~ i'7 r ..p:- pI) i-{ t:6-;; L ,;J a.,,( .:?-1"f A,I .A / T;~:-yI, vJ,~c/ ~f.Ar-t/~ ;4 tAlly~1-/ ";,..4 .p - O. 7 (~ f) / I, ,.t = ,;, 7 4 p;' T ~.. It (8) S-,74:::- r 7' l.{ f b" E1J ::: f:J.- (II, 6) (3 + 7) + O~Ff- !I. ~; /7rjJ -.::::- C:b '17 -I- '2-'" ,~ t >- }h-;'?/ /b~, Go <J~'" > W,A{ - /6 f'&, /6"7B _ r 1=: ~(16) >1 pli 16 ..., B ( 'f.. ') _ A -v-~ ":;:( J' )',,,,) ~ Jf ~'-j- Off Olr !9' tJ,. 3 i i I i i i I , I I I e f eJ' Tth1€ - ~ rA. f.~ p( &: ,11, lA, , ::r- 1ANf-€ '" ~ ~?- "-~~- ~ I If r)crj- ; t I' -e G',., 11 ~ ~ ...e.-,r-<d ~ I Y't;lt. ~-e~, '/II '" (1.7 : '7-X 6 e 7-- -P--"b. ~ r IC-,. r/~jj 11' ; .5 /:J '11?1 , / I /7- -F-P, 7 J--x(3 (}r hi e /6" C7/C/ ,t:) IIFrr-? /J t1.- 7-"t. i/ V /E- c7,C, 1.fZ c- ~ ',__ 'i ;-1/ vVl;(P' Z-- x- t fJ F #:-2 I. T ~ 2- eft C / J- X b p, T, de c f- ;y1.Y F JOt7r {J -< ~ ' '-I '- 6 . . F t ~ 'YJt1 d ?C.. ,.., ,;o/~r J-t-= ~s-(-:::)T JloflJ:.) + 6o(J)=JfJ5i,5 JJ '- -=:: I!;( %-;)r, s(}Z; ~ f) +'10 =,;,C:'IIf"' T--~n t ~;"IO t1~(O Ir#-z... I' , I " r If '1 ? ' "I:" L 'I ~ {,. ~ -1~ : ~., ~ ~1- thf ~ ... ~./d S. t-U ,f G,H.tI,. ,t( T~.e I () -; d'7~ ~7" 'J It '- ) .i1~_ ., ()II i> + t:7,1 ,,(; I'M ~ EIG /..$,7-;'/ ~ k1 ~, 4/1 wAI!? 5/",7 . ~ A- IA/;f~ P-l 10 VV 11" I rJl WI U ~....., . ... rlofl!""? >r,~,T1 o f '2- 2-() <!'f /' If/ /A Ti-y pt/ W 4' /1 IC<-'1 ~ I ~ rd I' -(.,( ci If'~ 1N,..,lt- 1),~ .,v.,/J ~t-e~ 7/~1 / f11 t1 ~ t-- J Cf r.j ~ yt7;' tl, -? ~,,/ b~ rl <f; / e"/ wii"h Tv M -Ik <P l ",' J E.J(,~1;;'/ f/v'e(II~ 7"-:01(, >''''';4..( ..-( ~ ( j j, ~-;t.~ -e ;;T- / Jt;";, ? c C9-V1-j-;'", v:' f-y 7i /) .[) W Yl d-~ ('" c/ 70 ~ ft.e Y" 1:';' f) 'f' ~ /5;;-~/ yI-f II, /' j) / t -€, 11" YI "f 17 ..,I t. / (/ ?t-F~ r 1/1'1 /' C 7' 20 :.v r+h L v1 P 'N t O!,{)., 1 () () I b , c~ ;J~t" , 'I.v Ctf/ t-/J..-7-e c t: w p{ //5-/ ,ptll ~r 1/ . 9 rJe>'Jpl-t; ~ac 4 v''/' II 11...;/ % 101 vJdl /1",1€5 , G '1-< ~ 7-o>?t (;> - tYCl$- ;-do/ FtPo-r;-:: r ~ t5l/H. t/, , , Z- X'~ o~ / to c.AJ v J'T~~ '~1: tJ .,,, ~ 9 /' Je, ~A-, ~ ~ The City of Port Angeles Building inspections Dept. Upon reviewing the single-family residential plans submitted for permit, the following are some of the items that will need to be taken in to consideration. 1- Foundation Footing. The minimum size of a footing in Seismic zone D2 are as follows. (1 Story 12" WI 6" min. thick) (2 story IS" WI 7" min. thick) (3 story 23" WI 8" min. thick) (Load bearing value of soil 1,500 (pst). With 2 # 4 bars horizontal continuous 3" off the bottom of footing. The minimum specified compressive strength of concrete in basement walls, foundation walls, exterior walls and other vertical concrete work exposed to weather in moderate weathering table R402.2 of the IRC is 3000lbs with a min. of 5% air entrained, but not more that 7%. Foundations in seismic categories D2 that exceed 50'-0" in either direction are required to have a continuous footing per section R403.1.2 including support of an interior braced wall line. Locating and marking the property boundary is required for a footing inspection. Tables in chapter 4 of the IRe. Will be applied for soils that are heavy in moisture (hydraulic) in nature or foundation wall over 5'-0" in height. Verify site conditions and unbalanced back fill at time of application. Foundations Drains are required as per section R 405.1 (see exception for soil classification) 2- Foundation walls. Vertical steel in foundation walls as of July 1st 2004. Vertical bar reqd to be Yz" #4 bar with a hook and tied to the footing steel in place at 4'-0" O.C. at footing inspection. One #4 bar horizontal within the top 12"of the wall. Yz" anchor bolt with a 3" x 3" x '14" steel washer is required at 6'-0"OC for a 1 story and 4'-0"OC for a 2 story, along and within 12" of each end the pressure treated sill plate. Crawl space ventilation is required at (1') s.f. of vent per (150') s.f. of area per sec. R408.2. 2003 IRC. 6 mill black poly is required in crawl space as a below grade moisture barrier per section R406.3.2 2003 IRC. Finish grade shall be a 6" slope away from foundation within 10'-0" of the foundation wall measured horizontally as per sec. R406.3 2003 IRC. 3- Framing. All connections from a pier to a post and beam are required to have positive connection per code. In addition any connectorsl fasteners in contact with treaded wood are req'd to be hot dipped zinc/galv. (See manufacture details.) All floor joist are required to be blocked with 2x material at the beam support. 7/16" OSB sheathing is required to be nailed to pressure treated sill plate and bottom plate or sole plate of wall. (or other approved hold down's). Attic ventilation is required at (1') s.f. of vent per (150') s.f. Of area with an allowable 50% of ventilation can be located in the upper portion of the ridge if applicable per 2003 IRe. Truss design and calculations are required upon submitting an application, lateral connections are required to end walls where truss I rafters are perpendicular to end walls. A truss Irafter tie shall be required to prevent uplift per code. 4- Braced Wall Lines. In Seismic category D2 exterior and interior braced wall lines cannot exceed 25'-0". Wall bracing must start within 8'-0" of a transverse wall or a designed collector. Standard wall bracing methods are required as per section R602.10.3 of the 2003 IRC. If the wall bracing methods cannot be met, then refer to "Alternate Braced wall panel" Section 602.10.6 of the 2003 IRC. If any of the aforementioned methods cannot be met, engineering design will be required for the "SHEAR WALL" design. Section R602.1 0.9 for interior braced wall line support for 1 and 2 story buildings require a continuous footing supporting a braced wall line, interior and exterior not to exceed 50'-0"intervals. 5- Egress. Rooms used for sleeping are required to have one window with 5.TS.F. of openable space and a sill height of not more the 44" above finished floor for emergency escape per 2003 IRC. 6- Energy and Air Quality. Insulation, Heating, Air conditioning, Lighting, Windows and Appliances to meet 2003 WSEC & VIAQ. New single family structures are required to have a whole house exhaust fan with a 24hr timer per table 3-1, 3-2, 3-3 of the 2003 VIAQ. Mechanical fresh air intake (FA!) is required to have a 24 hr timer or windows in all bedrooms and living, dining area may have intake ports for fresh air per 2003 VlAQ if zone heat is applicable. 7- Dry Wall. (Gypsum wall board) 5/8" type "X" sheets rock is required in the accessible usable space under stairs and on ceiling of a garage only if a habitable area is located above the garage. The rating of the sheet rock & nail pattern must be visible to the inspector. Nail pattern for all sheet rock Yz" and 5/8" to be 8" on center and 12" OC if drywall screws are used. Per table 702.3.5 of the 2003 IRC. Interior braced wall panels are to be inspected prior to tape, bed and texture. Moisture resistant wallboard is required around w/c. A cementuous backer board is required for tiled areas at tub and showers. Vapor barrier is required. A perm rated paint may be substituted for a poly vapor barrier on the warm in winter side. 8- Plumbing. Water heaters are required to have two approved seismic straps in the upper and lower 1/3rd of the tank per UPC. T&P valve to be '%" I.D and directed to the exterior and turned 90 degree downward not less that 6"-12" above finish grade. Water heater s are required to have a 26 ga. Pan of other approved drain pan with a 0/.." drain line from pan to exterior. Impact protection for wlh and mechanical equip are required to resist 6,000lbs impact iflocated in the garage area. All DWV are req'd. to be tested under water pressure per 2003 UPC or air test (consult manufacture recommendations for air test) Min. test pressure in Residential LPG is 30 Ibs. 9- Smoke detectors. shall be located in each sleeping room and in the hall leading to each sleeping area. One smoke detector is required at the top of each stairs, and at least one smoke detector is required on every floor level. Smoke detectors must be within 6" to 12"from the ceiling if mounted on wall. Smoke detector shall not be less than 36" from any air return. Power supply for smoke detectors shall be from the main house supply that is not switched and required to be battery back up. Smoke detectors to be inter-connected so that if one smoke detector alarm will start a chain reaction to all other smoke detectors as per code. 10- Maximum building height allowable is 30'-0" based on an average grade plain per 2003 IRC. Property pins shall be located and marked for a footing inspection to verify zoning set back requirements. 11- Safety glazed tempered glass required within 24" of any doorway edge, along with other requirements as per 2003 IRe. 12- All water, sewer, gas, electrical, drywells, downspouts and footing drains are required to be inspected before cover. This letter is not intended to cover all items required by the City of Port Angeles, but is to serve as a guide to help you understand frequently asked questions, "ALL WORK IS SUBJECT TO FIELD APPROVAL" 4/05. ,- i Ir~ ..... <l ::r- " \ \S - -----r ~ d ~c.\~ :'4" Z.~r .b l--- A ttc..<..h <' <I U c.-rz:.,J<- zz' 2. I ' I I I 3 ,----- /- I \ 11\ c.. '" - 2 0 ~-I- /93' I LJ' // // ,// I ~ 2 2.. M; I \vc.."'\ --- ',,- L-ot .s 11 <:::. J B 0 S'1 ~1 ~ t -----=rho"lSC:: / 352 .3'1 FI- G. ",rC. a<- - 4 & 2.. :5'} r: f- d..ec...lc... -= /80 3, p~ -:.. ,I 3 ~ 1/0 ( ~t- [ q '" c\ '-\.d ~) o..dd. h~) +okt II % Co verc.U-<'" 'Ii :/r:~ OVERVIEW EXISTING - NO SCALE , : mr--r.Tf1lTffil' lTTT'TfTFiTTT'TT1 jTTT~ I~~ I' I' II" 11,1 I I,11 t 'I II ,,'i' i ,I' ., ,,', I" Ii 11.1 1,1 I' 1"1 "," '''11''1'' ",' \itll:!I!:III,!I'lliiil,lilil' 'II \,llil,l:> ,! !:If:li ~l ~III' ' : ' , 'II ' " "I' " ' ' ': " '111;;::!I:il:ilt,!::i:::';!::I!1 Ill:!: , J:ii: :1 I " ' ' I11I1 ! ! II i' :! ' : I I' !' I:' I ': : , 'I :1 . II!! I'! III I: i II : i ' 'I" ' i I: i i : : ; : ;, ,: ,:' i 'I III i !: III i i i ii, II : I, I . ; , " i : i II ! ' ;' , I" "I' I ;1 :, " g)J-i.lJ , . , 0-" 1J ' ,: I I , : ' " 1.:..J- Y ~'~_,.J ~~~ ,'=; -,t:~---' (-::j - . , "I" Ii'" ! illlll'l ' , ' " J' ' , I ' II 'I ! ' I' '., I '1111 I. I , II' I ' , '" "[' :. , I' , ! I , . , " ," l I,tl' ;,,:,li ! j ::!Il: ! 'il[I:'!'II. , I" I ,,'I I I ,,"1,111' 1:'1" ,'I J ,I 'I' '1'1 "i I,,' i 'I' II " ,,: I 1'111111 ,,::,:., ! ',1'1 ','i'll" 'i', 11'1 j I! : i; 1i!J! I: i ! i i! 1'111' 'I! I UI III i II w:! " 11'11 !1!lll!:l",:I!;ltl,I~1 1111!': 1,', , 'r-'"J'" 'II I, I ' '1 ' , , ! ! I I I ! 1.Ll1.,-",'--:--'-1 '1r-J i I " ii"11I 1.l[l;..L' ,~~ ,--L-...J I CO '.Cl ~- '. ,J OVERVIEW PROPOSED - NO SCALE d,'.:''':','[ 'r' :' ~ FILE >- cL <C z - 2 - .-J W ~ lL REAR -NORTH 1/8" = l' 1/8" = l' (j DATE: 12-13-02 REV.: 04-21-03 ~ Wi P \D Wi ~ If) II \S) LU ~ UJ \!) Z < l- ,t'lL 10 Il:\.... I~ IUJ -.;t o ~ _., .. Z t'lL . t'lL 0 LU'Wl\- Z 'I D: < s:--l!u O,:=l,O i If) i ~ n_ ____ __-------'-__ z ~ \S) W D ~ Z D ---1 ::J cD W Z o \- \S) W >- W o ~ t<) I t"- '.0 -.;t 5' ~ t<) '--" C\l ~ ~ tnO) C\l<( ~3: Ii} . zli} ....JUJ ouj u\;) ~z ....J<( \fi\;2 ~?2 C\l c PAGE ./ / 1 /// OF // 3 / - ~ S3139NY l~Od 4~_tr 3 _tr09~ :NOI L YJOl I ------- ----------------., :~3Clllng ! N t<) 9 9 ~ N ~ ~ ~ ~ D n<: pl1~9l1Jg r ;/ \ ><: z ~ ~I 9 ~ m_tr~-Lc;-tr (09~) Z9'ZQ6 '.1M 'S3-139NV JilIOd flZ# ',1S Nl0jNJ1 'S 9lZ - -- --. .--.! :~3NMO I N91S3d 9Nldllng 3N01S3A3 r ------- --------------------- ,,0-,00 .-------.----- ---.-. -- ------.- ------.1 I 1--'--- "H-,<;; --+-- --- - --- -. ,./.-,Zl - -- -. --- -- ---"'" - ---- - --- - ,,<7-,9.L --- . - - -- --.; i I . I r ,,/,-,\..1-"- "o-,e;;; -.f . - -- "H-,I? - -- - -" ! ; +' _) r--- ___ ~,' i : o : ' Ci ! i .~ --, l'l-lI.-J ___ --1 ~ ____I L --- -- - ------ ~ I ;' ~ I . I rr; --- .. Ii 1.- 1 ~ ~ I " i w:= ! ,,.J i In .x L' z i? I IrTr~ ~W ' - __L lJ __~__ ___ "Z!L n-,'\1l C)__ _ _. _ _ ___~ 5> , 'I --1 , __ 1I0",C:;L _K_ ~ __.__~_n___._~_. "ll-,e;;; ~ It ~ .,- t? a ~ LLI m 0 t:L 0 t\L lL Z 0 \= -< I a i z I I ::::) 0 I tL , I ~ I I ~? I I f;j ~;~ I I flh2 I I li:~ir;) ~~~~ I I z~><1.!l t3~~l!l I ~~~~ ~!*ro I xl2.lSz I ;t~~~ I --- I I I I I I I r ___ ____ __ I r II I II II II II II II II I II I I I I I I I , ._ __ ___ _ - .___ __ ____ ___ ___ J I I r-- I I II : I II .1 I ,1 I I I , ! ' i I I! ~ I' ..- I II Ii ~ ' i I' I! ..- I \:) i i Z I I \- I m I II X I LLI I [ Z I II 0 I \- II -< I , I D I' Z , ! ! ::::) Ii 0 tL I I! - I ! o ','\... lL ",,0 t<J w " ~ ", -< '''"' ~ (\J , '- A21YNllAJll32Jd .. 33'-61/2" - 4'-3" -+000 -------1 I I I r-------, I ,~----1 ' -+_____, .J I 1 r----~L.--'1 -- - ----;--- L -__ =-t,~- -1 __,___ J J 1 r ' ---- -- -, '- "-i ~-~~~, p-, - 5CiM /'-~-1 / / 'I . I' I ; I ! - I -, ' ~--" /,--1" ,2050 '1',30""'" i 1. 'I I -- ,--, I' I - 2'-o".-~ i--S1/2'! ~- 3'-0. ~(3' I, I -0" - -~-1' t - -------..1-. i I I " i / ,/ Ii t ,L__,_______ CROSS SECTION 1/411 = l' F ! , _____________ _ _~______1 1 Ii : I I: , ! ! ! i 1 i 16'-0" ,lJ:,... l___J i ----.T~ --r 'T - T I ! / / ,----~-~~, 4- X 10 DF::2 HV,DER T'Y1'1CfLUNO ':Q in I~ ,~ o '1 >< , , -i+~ Ii t.<) " t\l $':1 '9 'Q , :1 Ii :t l!. MASTER BDRM 15'.5" x 11'-5' C-11'i , I : J I, , n 'I , ~ I' IN I I-~I L_ \, ,I ': r---- 1-.___1 I ' '---"ifl t___ i :! iii' I I 1111 f , ,1'1' ,,~II I i'l '~l'll g 'I ii;,,1 !:; I ! II ! " " , ~ , I ~ I , L ___n ~ L_ ____. ': I -~ ! $.~ I . ' " ' --i:; 'i' :r ~ 31/8 ~ 10 1.'2 24F-v'4 C-LUUJ,\ BE';.'" ';- -~-<O -'~_::7=:::r " f ~ / ,.// ~ I I I ~ I ;:: I I I " I >::! ' , ~ i , ! I __L :i- -,( , I I , I 9 ~ I '. t<l 1-1,- , I' , ,.. . t<i ''-9 ~, I-tlS,...wKE DETEC1C~S INTE~CON~E,...'lEOll0 vOLT WIl'A'fTCX'( ~^,lUJr ;f/\ ~ /r-:- 3'~1C" -.;r - \- -- ~ ......... ~ / - -i - - 1-1 - , <3.. J \ I ~~. i ~~ / \ 1>' 1 2""6 ~ HIS " ! CLC5ET , / -~..:~-~] I I HER CLCSET 5'-S"x+'-5" L__,_ ~ t<) <;1 g , I ~ - t<l ----, ~ l' ;--- r -3"-1" -; ~ t<) '!) .n ~ i I , I ~-" ,'-----~ ! I MASTER BATH 7'1".4'-11" I I I~" I'f . f: :\ --:I ! '- ,,,,,", 5I-t ". , --- r -- ,...: --7-6" --- I I CONTlNUOlI5lUDGEVENJ COMrOSIllON SHINOlE KDOF1OO 16# FELT 7/1ir~~THIHG rXE-MANTlWSSES 024"D.c ~..a& INSULAllON 61fJ" &we 6/4Xt)PRJMf[)Srroce FJ&..~&t'AAGE ~.. STYlE CONTlHOOUS METAl GI.1TlUS -..J ~~ ~~ TRUSS/N-^lJ. CONNECTlDN.. (") "'. NAlt.$ . (1) H5 HUIOOCANE T1E re: OOJ$$ ~ 1, ----. ~X Z+X12 ~>>-..."RET'E f"1~r"'D5 W!4X4rr rosr5fN~!.-r~ ....-_L..l....., ,- , ~~~ ~~ ~~Ce~~~> 1:'~~e~~G: ~ ,."-~~-,~- -- -/--- .--....."::------ c,. ........---...- ----- -- -... -- - ~= ------/ . -- ----~ ~ ~:::,,:>/< // ----------:::::....:::.>--- ~ ~=- ---~ <= I --:' i,,,:er: ,.. fC~-~:: ~:-::-:::::c ::::~~ H If 111 fT'lll---" i I '-" ~ I II':! il' ;1" I.. -, I 1 I 'll~'1 ii' I' ,1!41 , ' ij~11 I I ! ii' i ,: II q' . : i a/': , I III II " 41" l .1 , ij" I I, ~ I ': ,( .', I .: I 1 F i I 'II I Ii ,'ill ' , 1,:1, I' i ~ !, :' 1\ !" , " I ',.,,1 , 'III ' 1.1 H'l.l I " '"t..___ " " i. j'" j. ' ~".-;-;-'-~'~o I I 1III I " " iJ" J I ' ~ '11',i.', ,,", ,,' I I I~_________J.. II (,1', i I:: :, I:':,' ' . " ". I I II ill - 'n_ .____ __. ,.' "1 1 ' ij, 1'l"I"I!'" ", I .' I"r~-".-. _. u n_.~..L",_ ,II'III!I"""" , , I ' ., i .. n, ,.," ,C"' . ,-". . : I ' I ;11 ----- :; ~'- - ,-::.:=-: tL-:::-~ , I Ii!! I ' , 'I' fT '~"- " ' ,\ 1'111 ' I ~_L L ~-" 1 ' ' ' : , ' ' ' I ,11;.1 I ' III' I I'" ' , : 1 I :' I' . ' I 'I I I I' I ' I . .11 ,: ,'" . ' ' 'II II : I I ' " ! " I" I :: ;" I ' I 'j'! ! I ! ' I 'I ! '-_ ii illli!iiij'! r ___ I, '1111 i I : ' , " L_J ,---=====------ ll~ i ::!:!I ...--1-===~--=--- ____ ' III i 1111 _H ~_____________LJ -Ll.LJ Ll ~ MAIN FLOOR PLAN 1/411 = l' fL <C z 2 -1 UJ DL iL /~ DATE: 12-13-02 REY,: 04-21-03 ~ ';II ~ Ul Q;\ 1- tn 10 ti) UJ -1 UJ ~ Z -< b2 a ~ ....c ~ UJ ..q- a c.Q CLI CL z a UJ UJ - a \- Z, I -< s: = <..) a :::) a tn'-1 / // z ~ m w D ~ Z D .-J ::J cD W Z o \- m W >- W o ~ t{) I t'-- ~ ..q- o c.Q t{) '-" C\I ~ d:l cnm C\I l1<< ~~ (j) (j)' 3w o-l UW zO ~~ (j)~ It)lI<: ~o C\lt\... __ ___ __ __J ~~--.J __~+u__ ,~-----+-----_______o*< ~---- -- -- 49'-61/2'" ~~~:~=-j --- -- L_ ---- --- , , , DECK :'----CN--l: , ,~.. 25'-10"X1J'-~'~" ~- ~:-_..--~--=-'"~--.-I~-t~~-, ~~--~-:'-=---,:------~.~--~~-~-~~~'~l ---.-,'----4-v -~---- T-o ------{'----- C)-oJ ,-;ct"?I_-81'?--rrt>/--3-a *3-01/21----5-", ---'''T- - 4-0 -- rj __J __ _ _~ ___ __ --- ____I -- -- ~-~ -_0__ ---9l!-t~~- --- r-- -- ---1- -- --- --- 1--- --r --- I I I ~! 1: ! t 1 I " 3C~8' I -- : I ,11........0 5a.4C....v 1 , 1 , c PAGE / OF 3 / 3 CITY OF PORT ANGELES LICHT DEPARTMENT N~ 18049 ELECTRICAL PERMIT Port Angeles, wasbJngto~____n_nJ._"B_l(:______._________________________, 191:1 In accordance with the City Ordinance to regulate the Installation, extension, or repair ot elec- trical equipment In, on, or about any building or other structure In the City of Port Angeles, per- :~::s: li~~:~:.5):l:::;.~';;~:lJ1~_IO:~cupancy..i?4L______.______._.__._.._ owner'7:;:r~4_~-..n-"f6.l/:~~~&.------n.--...~--- Tenant.._._&~~_.._.nn________.nn.___________...__ Wiring Contracto~ ___~~-d.6...n~..nnn___ By...n_n..n.n___.mn_______.___..n___n______n____nn___m..n V rum u I;N/:.i '--/0 T . Light Outlets..............................._.._..... Service, volts ...........~.......................u ype of Wiring. ----- '..;J Receptacle Outlets' No wIres .; Armored Cable ...mm.........__.......... -...-.......................... . -.;,.--r"X........;J'7....... L--"" Dryer KW ...... ...~_.__......____.u.uuu Sfze wlrJ......1f...!?..........~~':'::'-~ Non-Metallic .................--............-- . - J....--" (''l/O ~....- ~:::'r K:e-~~~-;~.-n;;:;; ::~~o:::: ::::€:~:q.~~:: . Knob & Tube.............................m_ RIgid ConduIt ......................_......._ Metallic Tubing ..............m.......... KW.___......u~..-.p.........uu------u. Heat Kw....l~..~..I\...0J............... Type of wiring: Entrance Cable ........... Motors: size, volts and phase: Rigid Conduit ............u... Metallic Tubing ...............00 Current transformers: No. & Size............................. Raceway ..............................._....._ Circuits, LIght....................................... Utlllty.._........_......u.....u........_......... Heat ......................................._...... Ser. NO.n............................................ Range ............................................. Water Heater ....m....n.................. Motor ............................................. Ser. No. ...................................00........ Dryer ......................__........................_ Furnace .........................._................... ? oRee) Total I.oad...............n'............ Ser. NO......................................n...... Ser. No. ............................................. Total....................................... Remarks: n______nu____u_u..nnuuu_nnnnnuu.uu__._u_.___..nnnunnhn.__n_nunn_nn.uu_u.h_....nn__n_____nu.h_nnu.nnn_nnu...._un__..nn __..___________n________n___.___.._n._____.______nn________..__n_.m_.nm_.nn___nn___n.____n_..n._nnn___.___.______m.___nnn __ /"'7 ped t: ~ Tre~~?~. IJ// ~;;;~ $___________,_________..________..___.. NO.____m______m_______..... By zi~_..__....._________m)?<-------....---- '-----.. NOTICE-Current must not be turned on until Certificate ot Inspection has been issued. It work: is to be con- cealed due noUce must be given the Inspector so that work may be Inspected before concealment. NOTIFY THE INSPECTOR BY PERMIT NUMBER WHEN READY FOR INSPECTION N~ 1 80 4 9 ELECTRICAL PERMIT Addrescfii!-~~1f.~t!.L~hh.~c4i....... Date...~..h-:.2...t.=.L~_h :~:::~~~;~~~~~::::.:::::::::::~::::::::::~:h::~=:~:...:::::::::5gi?{:::~::::..~::~.~t.~~:.~::.::::..:::...:::::::::~:--.::::::: NOTICE-Current must n()t be turned on until Certificate of Inspection has been issued. It work is to be con- cealed due notice must be given the Inspector so that work may be inspected before concealment. 1M Olympic Printers, Inc. In accordance with the City Ordinance to regulate the installation, extension, or repair of elec- trical equipment in, On, or about any building Or other structure in the City of Port Angeles, per- mission is hereby granted to do electrical work as listed below. Address ..n..ln~.~.~n.mM!.~.~.~.~.~~.n.p.f3..'nnmn.__m Occupancy__nn:B-E?n:.m.nn__nnnnmmn Owner ...:1J.i'!1QJh.\4nmnlli.B:l.~nmm.__mn..m Tenant..._m~.M.~n.m_mm__.n.__nn____mm.__.m__n Wiring Contractor ___m__~.~~.~.m...nnn.n.__m. By.nn.._______n___.__n___mmm..n__m__m..nnn.mn.n__. .. \ . Service, volts ..._____.......'......................... Type of Wiring: , "/ ::.~nw:::s::::::::.::::::::..~~~::::::.::::::~ :::::~~::~:::....::....::.::.:::..:::.:.: / Rigid Conduit ...nmn......______......... CITY OF PORT ANGELES LIGHT DEPARTMENT Ltg It Outlets.........__.__n_.............._.._..... Ree eptacle Outlets...____............_.._.___.... Dry. r, KW oun........__..__._________.____..'; / Ran ;e, KW.._.___..m.___uu____u..______:._... / Water Heater: / KW.....m...nnnnnn.m.nmmn.nm... Heat: KW....._m...........___m./.................. / Motors: size, volts/and phase: / \ ::::::::::..:::::::::::::S:::::::::::::{;'::::: ~ ,. " :::::::::::::::::::::::'..:::::::..:"::::::::::\:::::: , mn.............................------r---...---....- Total Load..._________________h....... N~ 18011 ELECTRICAL PERMIT ~/ '\ /' {~ Port Angeles, Washlngton..n...__mm___.__.__...____.____.__..__..______.____., 19C?..~ Enclosure ______~___.............. Metallic Tubing h.........__un.......... Raceway .........._.._..___............_.__.._ Circuits, Light................___.____..........._._ Utlllty ___.m.m____________..___.um....___.... Type of Wiring: Entrance Cable __......._. Rigid Conduit ...on._h_......._ Metallic Tubing ............_.. Current transformers: Heat .._............_.__...................._....... Range ....._..____._..................________.._.. Water Heater .....___._______............._. Motor ........_____.._____._...............__...... No. & Size............___......__...........__... Ser. No.__._._____..........................___...... Ser. No.._.____....................__......_.___...... Dryer ___...____................____.................... Furnace _.._......................_......_._..._..__. Ser. No..____.___................................__... Ser. No. .-__..________._____.________________._______ Total._.______._________.................___ Remarks: .m=-.rJ:.:'MS.~m__~~'Ln--.n--m___unuum.mm...--.m...--mm__----u-----um--m.m--mn..-- :aA::#::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::=::::::::::::::::::::::::::::::::::::::::::::::::::::: Permit Fee Treas. Receipt It- at:. . c?-. $.n..__15!__9.'?...m.mnm. No....Q?rz.lti...__... By n__..mn.mfd.....__.mm.~..__ NOTICE-Current must nDt; be turned on until Certificate of Inspection has been issued. If work is to be con. cealed due notice must be given the Inspector so that work may be inspected before concealment. NOTIFY THE INSPECTOR BY PERMIT NUMBER WHEN READY FOR INSPECTION ~t~ ELECTffiCAL PERMIT Address ...n.Lk~.:2.::uun.Mu\.ldt!.B:.0.J~:~.g:n.n1>K:.nuu.___u.___...uu..u.nu.m00 Date.n_n?J~f_.M4-_mu._______..___.u.__ OW:ler mmn.umW-M__Q::!:h__I1.____M.I'iJ.R__umn.uuu____.____.___________.m.... Tenant..u_.msA:~..m4$?~{3.b 0(, Wiring Contractor.mm.us.\l:E.g.(?g.~:e..!~u...________...______..m._u____.m__...___.u..____.mn. By._______________________u_____.____._______.____.___.m.. N~ 18011 NOTICE-Current must nDt; be turned on until Certlt1cate of Inspection haa been issued. If work Is to be con- cealed due notice must be given the Inspector so that work may be inspected before concealment.