Loading...
HomeMy WebLinkAbout722 S Francis St - Building d'Ott'~_ ~;C} y;J CITY OF PORT ANGELES PUBLIC WORKS - ELECTRICAL DIVISION ~21 EAST 5TH STREET. PORT ANGELES. WA 91l~62 Application Number pin number Property Address ASSESSOR PARCEL NUMBER: Application description Subdivision Name Property Use Property zoning . . . Application valuation 04-00001177 Date .725825 722 S FRANCIS ST 06-30-00-0-2-2590-0000- COMM ADDITION 4/11/05 COMMERCIAL NEIGHBORHOOD 142260 Owner Contractor GREEN CROW TIMBER LLC PO BOX 2439 PORT ANGELES WA 983620312 MOORE CONSTRUCTION 1385 E. ELLIOTT CREEK RD. PORT ANGELES WA 98362 (360) 457-8890 REMODEL EXISTING AND ADDITION OF NEW QFF----- TYPE V NON-RATED BUSINESS:OFF/PRO/MED/REST TOTAL % LOT COVERAGE NUMBER OF STORIES EXISTING LOT COVERAGE LOT SIZE PROPOSED LOT COVERAGE TOTAL LOT COVERAGE NUMBER OF UNITS 10.61 1. 00 1228.00 22500.00 1160.00 2388.00 2.00 ,( \.-\ {'o Structure Information Construction Type Occupancy Type Other struct info ---------------------------------------------------------------------------- Permit Additional desc Sub Contractor Permit Fee Issue Date Expiration Date ELECTRICAL NEW COMMERICAL HALVORSEN/ 200A SVC OFFICE HALVORSEN ELECTRIC 95.80 4/11/05 10/08/05 Plan Check Fee Valuation .00 o ~ ... Qty 1. 00 Unit Charge Per 95.8000 ECH EL-COM 101-200 NEW SRV FEEDER Extension 95.80 ~ "- (\ ---------------------------------------------------------------------------- Special Notes and Comments Building address sign shall not be less than 6" & not more than 12" in height. Numbers colors must contrast with wall color they are mounted on. (Ord. 14.36.050-E) When roof gutters are installed, drains will located in dry wells or piped to approved storm drain locations. Comments from Fire Department are seperate and attached. proposal will result in an office addition in the CO zone for lot coverage of 12%(2908 sq.ft.) Setbacks are good. 11 off-street parking spaces are provided - 7 are required. Dimension changes on Parking Lot design, see site plan attached with changes required. Electrical load calculations and elctrical permits are required. MArNTAIN CLEARANCES FROM SERVICE WIRES '. It,. ~ Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Totar 95.80 95.80 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 95.80 95.80 .00 .00 COMMENTSI ACTION NEEDED ELECfRICAL PERMIT INSPECfJON RECORD CALL 417-4735 FOR ELECTRICAL INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLA WFUL TO COVER, INSULA TE OR CONCEAL ANY WORK BEFORE IT IS INSPECTED AND ACCEPTED. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPEcnON TYPE DATE ACCItPTltD COMMENTS YES NO UnCH. ~{)T 1{~1-I-lN I COVER ..~'"' ~ ..... SERVICE FINAL I GENERAL COMMENTS: PW.II02.1~ (41961 '~ "Ioiir;;- CITY OF PORT ANGELES PUBLIC WORKS - ELECTRICAL DIVISION ~21 EAST 5TH STREET. PORT ANGELES. WA 911:\62 Application Number pin number . . . . 04-00001177 .725825 Page 2 Date 4/11/05 COMMENTS/ACTION NEEDED ELECfRICAL PERMIT INSPEQ'JON RECORD CALL 417-4735 FOR ELECTRICAL INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLA WFUL TO COVER, INSULA TE OR CONCEAL ANY WORK BEFORE IT IS INSPECTED AND ACCEPTED. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPEcnON TYPE DATE COMMENTS NO 9, ~- ~J GENERAL COMMENTS: PW.II02.l~ (41961 '~ "Ioiir..'" CITY OF PORT ANGELES PUBLIC WORKS - ELECTRICAL DIVISION ~21 EAST 5TH STREET. PORT ANGELES. WA 911:\62 Application Number Application pin number Property Address ASSESSOR PARCEL NUMBER: Application type description Subdivision Name Property Use Property zoning . . . Application valuation 04-00001177 Date 725825 722 S FRANCIS ST 06-30-00-0-2-2590-0000- COMM ADDITION 4/28/05 COMMERCIAL NEIGHBORHOOD 142260 Owner Contractor Structure Information Construction Type Occupancy Type Other struct info 000 MOORE CONSTRUCTION 1385 E. ELLIOTT CREEK RD. PORT ANGELES WA 98362 (360) 457-8890 000 REMODEL EXISTING AND ADDITION OF NEW OFF TYPE V NON-RATED BUSINESS:OFF/PRO/MED/REST TOTAL ~ LOT COVERAGE NUMBER OF STORIES EXISTING LOT COVERAGE LOT SIZE PROPOSED LOT COVERAGE TOTAL LOT COVERAGE NUMBER OF UNITS 10.61 1. 00 1228.00 22500.00 1160.00 2388.00 2.00 -..J ~ ~ GREEN CROW TIMBER LLC PO BOX 2439 PORT ANGELES WA 983620312 Permit . . . . . Additional desc . Permit pin number Sub Contractor Permit Fee Issue Date Expiration Date ELECTRICAL NEW COMMERICAL ANG. COMM./VOICE DATA 47951 ANGELES COMMUNICATIONS INC. 42.20 Plan Check Fee 4/28/05 Valuation 10/25/05 .00 o v Qty 1. 00 Unit Charge Per 42.2000 EL-LOW VOLT SYS <=2500 SQFT Extension 42.20 '- ~ ~ (\ " V Special Notes and Comments Building address sign shall not be less than 6" & not more than 12" in height. Numbers colors must contrast with wall color they are mounted on. (Ord. 14.36.050-E) when roof gutters are installed, drains will located in dry wells or piped to approved storm drain locations. Comments from Fire Department are seperate and attached. Proposal will result in an office addition in the CO zone for lot coverage of 12%(2908 sq.ft.l Setbacks are good. 11 off-street parking spaces are provided - 7 are required. Dimension changes on Parking Lot design, see site plan attached with changes required. Electrical load calculations and elctrical permits are r<;,quired. MAINTAIN CLEARANCES FROM SERVICE WIRES t1 '\ Fee summary Charged Paid Credited Due ----------------~ ---------- ---------- ---------- ---------- Permit Fee Total 42.20 42.20 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 42.20 42.20 .00 .00 COMMENTS/ACTION NEEDED ELECfRICAL PERMIT INSPEQ'JON RECORD CALL 417-4735 FOR ELECTRICAL INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLA WFUL TO COVER, INSULA TE OR CONCEAL ANY WORK BEFORE IT IS INSPECTED AND ACCEPTED. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPEcnON TYPE DATE COMMENTS NO '(;) - ;z -0 -)' GENERAL COMMENTS: PW.II02.1~ (41961 cfr"ORT ""-'G: !;,...~~<.. ~naW ~-- ~-~ CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY DEVELOPMENT - BUILDING DNISION 321 EAST 5TH STREET, PORT ANGELES, WA 98362 , I Application Number pin number Property Address ASSESSOR PARCEL NUMBER: Application description Subdivision Name Property Use Property Zoning . . . Application valuation 04-00001177 Date .725825 722 S FRANCIS ST 06-30-00-0-2-2590-0000- COMM ADDITION 4/01/05 COMMERCIAL NEIGHBORHOOD 142260 Owner Contractor GREEN CROW TIMBER LLC PO BOX 2439 PORT ANGELES WA 983620312 MOORE CONSTRUCTION 1385 E. ELLIOTT CREEK RD. PORT ANGELES WA 98362 (360) 457-8890 REMODEL EXISTING AND ADDITION OF NEW OFF----- TYPE V NON-RATED BUSINESS:OFF/PRO/MED/REST TOTAL % LOT COVERAGE NUMBER OF STORIES EXISTING LOT COVERAGE LOT SIZE PROPOSED LOT COVERAGE TOTAL LOT COVERAGE NUMBER OF UNITS 10.61 1. 00 1228.00 22500.00 1160.00 2388.00 2.00 '.j ~ N Structure Information Construction Type Occupancy Type Other struct info Permit Additional desc Permit Fee Issue Date Expiration Date ELECTRICAL ALTER COMMERCIAL 36.40 4/01/05 9/28/05 Plan Check Fee Valuation .00 o 1 l.1 1.1\ ").. ~ c\\ ~ ~ 0) '\ Qty 1. 00 Unit Charge Per 36.4000 EC EL-LOW VOLTAGE Extension 36.40 Special Notes and Comments Building address sign shall not be less than 6" & not more than 12" in height. Numbers colors must contrast with wall color they are mounted on. (Ord. 14.36.050-E) When roof gutters are installed, drains will located in dry wells or piped to approved storm drain locations. Comments from Fire Department are seperate and attached. Proposal will result in an office addition in the CO zone for lot coverage of 12%(2908 sq.ft.) Setbacks are good. 11 off-street parking spaces are provided - 7 are required. Dimension changes on Parking Lot design, see site plan attached with changes required. Electrical load calculations and elctrical permits are required. MAINTAIN CLEARANCES FROM SERVICE WIRES Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 36.40 36.40 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 36.40 36.40 .00 .00 Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction orwork is suspended or abandoned for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Signature of Owner (if owner is builder) Date Signature of Contractor or Authorized Agent Date T:IPoliciesll 102_15 building permit inspection record05.wpd [1/4/2005] BUILDING PERMIT INSPECTION RECORD CALL 417-4815 FOR BUILDING INSPECTIONS. CALL 417-4735 FOR ELECTRICAL INSPECTIONS. CALL 417-4807 FOR PUBLIC WORKS UTILITIES '~LEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE. INSPECTION TYPE DATE ACCEPTED COMMENTS YES I NO FOUNDATION: FOOTINGS WALLS FOUNDATION DRAINAGE / DOWN SPOUTS PIERS POST HOLES (POLE BLDGS.) PLUMBING UNDER FLOOR / SLAB ROUGH-IN WATER LINE (METER TO BLDG) GAS LINE BACK FLOW / WATER AIR SEAL WALLS CEILING I I FRAMING JOISTS / GIRDERS SHEAR WALL/HOLD DOWNS WALLS / ROOF / CEILING DRYWALL (INTERlOR BRACED PANEL ONLY) T-BAR INSULATION SLAB WALL / FLOOR / CEILING I I MECHANICAL HEAT PUMP / FURNACE / DUCTS GAS LINE WOOD STOVE / PELLET / CHIMNEY COMMERCIAL HOOD / DUCTS MANUFACTURED HOMES FOOTING / SLAB BLOCKING & HOLD DOWNS SKIRTING tfc.1rt6 i-f - /1./ 7 :S/""/~ PLANNING DEPT. SEPARATE PERMIT #'s SEPA: /17./ /lev -1;h~ :: PARKINGILIGHTlNG ESA: LANDSCAPING SHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/uSE RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED YES NO ELECTRlCAL - LIGHT DEPT. 417-4735 1,18!.? :7' AcO ELECTRlCAL LIGHT DEPT , I CONSTRUCTION - R.W. CONSTRUCTION R.W. / PW/ ENGINEERING 417-4807 PW / ENGINEERING FIRE 417-4653 FIRE DEPT. PLANNING DEPT. 417-4750 PLANNING DEPT. BUILDING 417-4815 BUILDING T:\Policies\1102_15 building permit inspectIOn record05.wpd [1/4/20051 t) ~ '-- -.... ~ BUILDING PERMIT - APPLICATION Fill out COMPLETELY and in INK. Your application and site.plan MUST BE COMPLETE to be accepted for review. If you have any questions, call (360) 417-4815 Applicant or Agent:.JJi.1wr16t-/e Mf~ Phone: Owner:6eet'\ rmw P~r.J-i.,.s- Phone: Address: 72..2-S . ~nLI ~ City: Bs(~1P~~ ArchitectJEngineer: Phone: Contractor_PeVlI''W1-,;/ ,.d~L1I rState License #:-.Pr:;N1V H1~ Address: 50? W Sti:1.- City:~t--l/v1jP,lR<; PROJECT ADDRESS: 12- z... 5. -fra n Co'l S S1:- LEGAL DESCRIPTION: Lot: Block: CLALLAM COUNTY PARCEL NUMBER: Subdivision: Credit Card Holder Name: Billing Address: Credit CardType VISA . MC # TYPE OF WORK: o Residential 0 New Constr. 0 Re-roof o Multi-family 0 Addition 0 Move IIl-'Conlmercial 0 Remodel 0 Demolition_ D. Repair. ,0 Sign - BRIEF DESCRIPTION OF THE PROJECT: '-I-57-?' 77 S- L{-~2-33:2-S- Zip: q ~ t. ? Phone: L/ ~""7-d. 77. Zip: q ~b"] ZONING: City: Exp. Date: - - APPROVALS: PLANNING USE ONLY: PLAN: - BLDG: DPWU: SEP A Checklist required? 0 Yes 0 No Other: FIRE: ESAlWetland(s): 0 Yes 0 No OTHER: - or o Stove _ o Garage o Deck o Other COMMERCIALIRESIDENTIAL: Occupancy Group: No. of Stories: Lot Size: Existing Sq. Ft. Existing lot coverage % & Proposed lot coverage Occupant Load: & Proposed Sq. Ft. % = Total lot coverage ISF. = $ ISF, =$ .$ . "" '2pt::> Construction Type: = TOTAL Sq.Ft. % BillLDING PERMIT APPLICATION SUBMITTAL: The Building Division can provide you with information on the application and plan submittal requirements if you have questions. VALUATION OF CONSTRUCTION: In all cases, a valuation amount must be entered by the applicant. TIlls figure will be reviewed and may be revised by the Building Division to comply with current fee schedules. Contact the Pennit Coordinator at 417-4815 for assistance. PLAN CHECK FEE: IF a plan check fee is due it mnst be submitted at the time the building.pennit application and construction plans are submitted. All other pennit fees are due at the time of pennit issuance, EXPIRATION OF PLAN REVIEW: Ifno pennit is issued within 180 days of the date of application, the application will expire. The Building Official can extend the time for action by the applicant up to 180 days upon written request by the applicant (see Section 107.4 of the Uniform Building Code, current edition). No application can be extended more than once. correct. I am authorized to apply for this permit and t lust 0 in such pennits prior to work. ate: 3/?O/.1S-- , / T:\FORMS\APPS\Buildingpermit. wpd Applicant 4vL:J lk~s ~trical Coa\nlctor Cl Annual Permlt a Alarm (J owner. a Cllrnlval CJ COrJ'merclaJ 0 Resldenttal 0 Restd4'!nttlll Malnt. 0 Signs 0 Thermostat ELECTRICAL WORK PERMIT APPLICATION ,.. o Request Inspection Thleco.ro. Installation description Job wired by '")il.lectrlcal ContradOr 0 Owner l,.icense number !.Joice ~ Zhh ~o Z/1_ Ho. "'vI,? 1 hereby certify thBt 1 am the owner of the above named property or a licensed electrical contractor (or the firm's authorized agent) and am waking the ~.\~tdcal mstallation Of alteration. in compliance with the ele<:tricallaw, Chapter 19.28 RCW. o Cash 0 Check # o Credit Card Visa Mastercard Discover Card # . . -----------...-.---- "n ri Ie Expiration Date of card z.-{) x Siena Insulatioh Only CEJUNG Insulation OnlY THERMOSTAT SERVICE nttl "f'PI"'~9Y D... A.PVfOYtd. By ~e AWIO'vedil)' sI.J, ., Cover ~-L? Ie -,pprove4 &y Dale ,"PPl"tlVtAl 51' :;_/... /;,~vor .dr>f) ,'r;}c ~~~~~ If)' DrrcH liEEDER DlIte Appl'O'lcdllY Due: Approved Dy Service Information ElActrical Lnad Additions and Dr subtractions o NO LOAD CHANGES o Baseboard KW o Fumace KW a Heat pump Ton LAR (J Fan-Wall _ KW Inspedion Atea, Building or Equipment Inspected Action Taken Electrical Date Inspector -C:;-7-05 f1;A1 ffL. ~ ArCJ<. ) Cl Overhead Service Cl Temp Se1Vic<l o Underground Service Voltage Phaae0103 Service Slze~ Feeder Size: .&7/7 L/~/_I__ ~ ~77\ ELECTRICAL WORK PERMIT APPLICATION o Request Inspection f o Electrical Contractor 0 Owner Q Annual Permit 0 Alarm 0 Carnival )(. Commercial 0 Residential 0 Residential Maint. 0 Signs Q Thermostat 0 Telecom. Job wired by )i'Electrical Contractor 0 Owner Installation description t)J:T-I/'.r- e(?p~ <;j:RVJc:E Electrical contractor name License number I /j;JLlII5Rr;EA/ ,<; FI8'TRIC fI/JLI//)CZ()"l'9~1 Purchaser's mailing address . '2.44 2 PL~/'E /?n City State ZIP P"I<T /WC-FlE<; 983"3 Teiephone number FAX number 5 Premises owner's name CREEP /'RIJ/I/ Address of inspection 811 <I FA'ln.Jo.<: City ??'Z. .$~ rA?1\Jc:..t/I...5 -s I hereby certify that I am the owner of the above named property or a licensed electrical contractor (or the firm's authorized agent) and am making the electrical installation or alteration in compliance with the electrical law, Chapter \9.28 RCW. o Cash 0 Check # ~ Credit Card ~ Mastercard Discover Card# _.Q~E!~__-____-____ Signature of owner, electrical contractor or electrical administrator X '~ Expiration Date of card Inspection fee $ 9',BtJ G -c:::. / WALLS Insulation Only Date Approved By 5'hlo': cover~ I Jf)ale Approved By CEILING Insulation Only Dale Approved By ~?om AlJ/) ~D e Approved By TIIERMOSTAT Date Appro\'cd By DITCH Date Approved By SERh ~1-dS Appw",' By - Dale Approved By ~ ~ '\:: I ~ FEEDER Electrical Load Additions and or subtractions o NO LOAD CHANGES o Baseboard KW il( Furnace i!i KW , ~Heat Pump Ton LAR o Fan-Wall KW Service Information )f Overhead Service o Temp Service o Underground Service Voltage 12t:>/Z4tJ Phase.8:l' 1 0 3 Service Size: 2rJp/J Feeder Size: Area, Building or Equipment Inspected Action Taken .e.((:..;<......~ 1 " $I/O q/u / ~