Loading...
HomeMy WebLinkAbout1032 W 13th Street - Building '".aa or i ELECTRICAL PERMIT - ‘, CITY OF PORT ANGELES 360417-4735 Application Number 16-00000391 Date 3/18/16 Application pin number . . 549939 Property Address 1032 W 13TH ST ASSESSOR PARCEL NUMBER: 06-30-00-0-3-9635-0000- REPORT STATE SALES TAX Application type description ELECTRICAL ONLY on your excise tax form Subdivision Name Property Use to the City of Port Angeles Property Zoning RS7 RESDNTL SINGLE FAMILY (Location Code 0502) Application valuation . . . 0 Owner Contractor FRENCH VONDA L PROTECT YOUR HOME 1 1032 W 13TH ST 3750 PRIORITY WAY SOUTH DRIVE PORT ANGELES WA 983637221 #200 - , INDINAPOLIS IN 46240 (317) 810-4720 Permit ELECTRICAL ALTER RESIDENTIAL Additional desc . Permit Fee . . . 64.00 Plan Check Fee . . .00 1 Issue Date . . . 3/18/16 Valuation . . . . 0 Expiration Date . 9/14/16 Qty Unit Charge Per Extension 1.00 64.0000 ECH EL-SINGLE CIR LIMITED RES 64.00 I Fee summary Charged Paid Credited Due Permit Fee Total 64.00 64.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total '64.00 64.00 .00 .00 illo INSPECTION TYPE DATE: RESULTS: INSPECTOR: DITCH SERVICE i ROUGH-IN • FINAL COMMENTS: PERMIT WILL EXPIRE SIX(6)MONTHS FROM LAST INSPECTION Signature of owner or Electrical Contractor X Date: C.,........„t‘ ,yOH(iir;CITY OF PORT ANGELES PER;\MIT APPLICATION _ t - Y (`,Building Division/Electrical Inspections �"Vn321 East Fifth Street–P.O.Box 1150/Port Angeles Washington,98362 ; V Ph:(360)417-4735 Fax:(360)417-4711 r. late: 3/16/2016 _1&2 Single Family Dwelling 'Ran ReviewM3y Be Regi.rired,R v Con-dote Sia >l Ran Review Inforrrti i Sheet ,fobAddress: aildrg awe FaolaK —..__.._.. cesciptiat d axwe Installation of a low voltage home security system Omer InformationVonda French Contractor Information ti reP13rra Protect Your Hann_ MealirgPddess` 1032 W_13th St_. MiilirgAdiess 3750 Prot r,Way s,_, c qty Port Angeles sate: WA ze: " gB3B3 Oty, Indpls stag lno _ Zr Ft ne:36047713.634_Fa____. Fins 866-502-3559 F 31 7-564254.__....... License#/Exp. LicerEe#/Exp. PROTEYH934Rs exp 12/1U;_01;3,__,__ Item Unit Charoe Cly Total(Qty M.tltioi.ii,,e by Unit(Theme), Service/Feeder 200Arrp. $120.00 $__—__...__. Sam ca'Feeder201-400Amp. $14&00 $__ .---._.._...... Service/Feeder 401 60D Arp $?06 00 • $ Service/Feeder 601-1000 Arrp. $26200 $. Savica'Feeder vier 1000 Arrp. $37300 $ Branch C rail vii'Service Feerbr $ 500 $__________. Brach rail Service Feeder 6303 Each Aditc el Brandi Ortait $ Soo Balch Orate 1-4 $ 7500 $ .._. ..... T .Service'Feeder 200 Arp. $ 9300 $....__............_._... Tarp,Servic6'Feec+er 201-400 Arp. $110.00 $-_ Tarp.SerHcaFeeder 401-600 ATP. $149.00 . .... $ Tarp SaviceFeeder601-1000Arp. $16BA0T_---. $' Portal to Rxtal Fbuty $ 9&00 $ - Sgrol Omit/united Energy-18 2 rarriy DAdiing $ 64.00 i $ 64 00 ._.__. fy n.tadured Hone Connection $120.00 $._________.._..... Penev able Electrical Energy-5(VA 9,rstan a Less $10200 Thermostat $ 56.00 $— - Nle$5.00 for each aiitiaai T-Sat NEW OCNSTRUCT1ON QALY: first 13:0 Sere R. $12000 $_._.._.. ......._._.. Each Adcitiaal 500 are R.or Ration of $ 40.00 $_._ Eat at:dicinga Detadled Garage $ 74.00 Each gni wring Rid or F#Tit $110.00 _._.... $-_-- 64 00 Tot-ii Owner as defined ty RC.W.19.28.261:(1)CM.ner v6ll oaxpy the structure for two years after this electrical permit is finaPzed 2;0,Nies is r cza irra9 to tire an electrical c crlravtor if above said property is for sale,rent or lease.Permit expires after six months of last inspection. After reefing the above staianent,I herdry certify that I am the c net ot the above named property or a iicerF/oi electrical ccnirriIi,r.1 of.rrals:ixj the detrital installation or alteration in corrpl lance with the electrical laws,R1EC.,FOAL Chapter 1928,WAC.Geller 26-45t3 t CO C of Pod Angeles M nidpal Code,and Utility Specifications and PMC 14.05.050 regarcfrg Electrical Penni Applications. Signature of owner,electrical contractor or electrical administrator: ❑ cast, ❑ ch ® Dedt Card#tigelfgaiiateit x Dae-Kwon Roberts gym: 3/16/2016 „„ Otlpl/d)12 Application Number . . . . . 22-00001471 Date 11/23/22 Application pin number . . . 516214 Property Address . . . . . . 1032 W 13TH ST ASSESSOR PARCEL NUMBER: 06-30-00-0-3-9635-0000- Application type description ELECTRICAL ONLY Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . RS7 RESDNTL SINGLE FAMILY Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc PV system ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ FRENCH VONDA L LUMIO HX, INC 1032 W 13TH ST 1550 W DIGITAL DR PORT ANGELES WA 983637221 LEHI UT 84043 (360) 637-4343 ---------------------------------------------------------------------------- Permit . . . . . . ELECTRICAL ALTER RESIDENTIAL Additional desc . . Permit Fee . . . . 240.00 Plan Check Fee . . .00 Issue Date . . . . 11/23/22 Valuation . . . . 0 Expiration Date . . 5/22/23 Qty Unit Charge Per Extension 2.00 120.0000 ECH EL-0-200 SRV FEEDER 240.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 240.00 240.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 240.00 240.00 .00 .00 Public Works and Utilities Department 321 E. 5th Street, Port Angeles, WA 98362 360.417.4735 | www.cityofpa.us | electricalpermits@cityofpa.us EL1-2 SF 1 - 2 SINGLE-FAMILY ELECTRICAL PERMIT APPLICATION Project Address: Project Description: Single-Family Residential Duplex / ARU Building Square footage: OWNER INFORMATION Name: Email: Mailing Address: Phone: ELECTRICAL CONTRACTOR INFORMATION Name: License: Mailing Address: Expiration Date: Email: Phone: PROJECT DETAILS Item Unit Charge Quantity Total (Quantity x Unit Charge) Service/Feeder 200 Amp.$120.00 $ Service/Feeder 201-400 Amp.$146.00 $ Service/Feeder 401-600 Amp.$205.00 $ Service/Feeder 601-1000 Amp.$262.00 $ Service/Feeder over 1000 Amp.$373.00 $ Branch Circuit W/ Service Feeder $5.00 $ Branch Circuit W/O Service Feeder $63.00 $ Each Additional Branch Circuit $5.00 $ Branch Circuits 1-4 $75.00 $ Temp. Service/Feeder 200 Amp.$93.00 $ Temp. Service/Feeder 201-400 Amp.$110.00 $ Temp. Service/Feeder 401-600 Amp.$149.00 $ Temp. Service/Feeder 601-1000 Amp.$168.00 $ Portal to Portal Hourly $96.00 $ Signal Circuit/Limited Energy - 1&2 DU.$64.00 $ Manufactured Home Connection $120.00 $ Renewable Elec. Energy: 5KVA System or less $102.00 $ Thermostat (Note: $5 for each additional)$56.00 $ First 1300 Square Feet $120.00 $ Each Additional 500 square feet``$40.00 $ Each Outbuilding / Detached Garage $74.00 $ Each Swimming Pool / Hot Tub $110.00 $ TOTAL $ required to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection. After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I am making the electrical installation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296- Date Print Name Signature (Owner Electrical Contractor / Administrator) New Construction Only [Electrical Permit Applications may be submitted to City Hall or electricalpermits@cityofpa.us or faxed to 360.417.4711] Lumio LUMIOHI784K4 PREPARED 11/22/22,14:41:53 PAYMENT DUE CITY OF PORT ANGELES PROGRAM BP820L --------------------------------------------------------------------------- APPLICATION NUMBER:22-00001471 1032 W 13TH ST FEE DESCRIPTION AMOUNT DUE --------------------------------------------------------------------------- ELECTRICAL ALTER RESIDENTIAL 240.00 TOTAL DUE 240.00 Please present reciept to the cashier with full payment SCOPE OF WORK TO INSTALL A ROOF MOUNTED SOLAR PHOTOVOLTAIC SYSTEM AT THE OWNER RESIDENCE LOCATED AT 1032 W 13TH ST, PORT ANGELES, WA 98363, USA. THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. THE PV SYSTEM DOES NOT INCLUDE STORAGE BATTERIES. EQUIPMENT SUMMARY 33 Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULES 33 ENPHASE IQ8PLUS -72-2-US (240V) MICROINVERTERS GENERAL NOTES THESE CONSTRUCTION DOCUMENTS HAVE BEEN BASED ON FIELD INSPECTIONS AND OTHER INFORMATION AVAILABLE AT THE TIME. ACTUAL FIELD CONDITIONS MAY REQUIRE MODIFICATIONS IN CONSTRUCTION DETAILS. • ARCHITECT HAS NOT BEEN RETAINED TO SUPERVISE ANY CONSTRUCTION OR INSTALLATION OF ANY EQUIPMENT AT SITE. • CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL, EQUIPMENT, TOOLS, OBTAINS ALL PERMITS, LICENSES AND PAY ALL REQUIRED FEES AND COMPLETE INSTALLATION. • CONTRACTOR HAS THE FULL RESPONSIBILITY TO CHECK AND VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS. ANY DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER BEFORE PROCEEDING WITH THE WORK. ANY WORK STARTED BEFORE CONSULTATION AND ACCEPTANCE BY THE ENGINEER SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE SUBJECT TO CORRECTION BY THEM WITHOUT ADDITIONAL COMPENSATION. • DAMAGE CAUSED TO THE EXISTING STRUCTURE, PIPES, DUCTS, WINDOWS, WALL, FLOORS, ETC. SHALL BE REPAIRED TO THE ORIGINAL CONDITION OR REPLACED BY THE CONTRACTOR AT NO ADDITIONAL COST. • THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR THE PROPER INSTALLATION AND COMPLETION OF THE WORK WITH APPROVED MATERIALS. • NO CHANGES ARE TO BE MADE WITHOUT THE CONSULTATION AND APPROVAL OF THE ARCHITECT. • CONTRACTOR SHALL OBTAIN BULDING PERMIT. NO WORK TO START UNLESS BUILDING PERMIT IS PROPERLY DISPLAYED. • ALL WORKMANSHIP AND MATERIALS SHALL BE OF FIRST QUALITY AND IN COMPLIANCE WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE, THE DEPARTMENT OF ENVIRONMENTAL PROTECTION AND ALL PERTINENT AGENCIES. • IT 1S ESSENTIAL THAT ALL WORK PROCEED WITH THE MAXIMUM COOPERATION OF ALL PARTIES AND WITH MINIMUM INTERFERENCE TO THE OCCUPANTS WITHIN THE BUILDING. THE OWNER'S DIRECTIONS IN THIS REGARD SHALL BE FULLY COMPLIED WITH. • ALL EXPOSED PLUMBING, HVAC, ELECTRICAL DUCTWORK, PIPING AND CONDUITS ARE TO BE PAINTED BY GENERAL CONTRACTOR. • THE CONTRACTOR SHALL PERFORM THE WORK IN STRICT CONFORMANCE WITH THE LOCAL LAWS, REGULATIONS AND THE NATIONAL ELECTRIC CODE. • THE CONTRACTOR SHALL OBTAIN ALL PERMITS, APPROVALS, AFFIDAVITS, CERTIFICATIONS, ETC. AND PAY ALL FEES AS REQUIRED BY THE LOCAL AUTHORITIES. • CONTRACTORS SHALL OBTAIN FIRE CERTIF. UPON COMPLETION OF WORK.• ELECTRICAL NOTES ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION.• ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. • WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. • WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. • WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. • ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE.• MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURERS INSTRUCTION. • MODULE SUPPORT RAIL SHALL BE BONDED TO THE MODULE• GOVERNING CODES 2020 NATIONAL ELECTRICAL CODE 2018 INTERNATIONAL FIRE CODE 2018 INTERNATIONAL BUILDING CODE 2018 INTERNATIONAL RESIDENTIAL CODE WASHINGTON ADMINISTRATIVE CODE (WAC) AHJ NAME : PORT ANGELES CITY WIRING AND CONDUIT NOTES ALL CONDUIT SIZES AND TYPES SHALL BE LISTED FOR ITS PURPOSE AND APPROVAL FOR THE SITE APPLICATIONS • ALL PV CABLES AND HOMERUN WIRES BE #10AWG *USE-2, PV WIRE, OR PROPRIETARY SOLAR CABLING SPECIFIED BY MFR, OR EQUIVALENT; ROUTED TO SOURCE CIRCUIT COMBINER BOXES AS REQUIRED • ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE DERATED ACCORDING TO AS PER LATEST NEC CODE. • EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2, 90°C RATED, WET AND UV RESISTANT, AND UL LISTED RATED FOR 600V, UV RATED SPIRAL WRAP SHALL BE USED TO PROTECT WIRE FROM SHARP EDGES • PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED THHN/THWN-2 INSULATED, 90°C RATED, WET AND UV RESISTANT, RATED FOR 1000V PER NEC 2017 • 4-WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH THE HIGHER VOLTAGE TO GROUND MARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE MEANS • ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION• VOLTAGE DROP LIMITED TO 2%• AC CONDUCTORS >4AWG COLOR CODED OR MARKED: PHASE A OR L1- BLACK, PHASE B OR L2- RED, PHASE C OR L3- BLUE, NEUTRAL- WHITE/GRAY • VOLTAGE DROP LIMITED TO 2%• AC CONDUCTORS >4AWG COLOR CODED OR MARKED: PHASE AOR L1- BLACK, PHASE B OR L2- RED, PHASE C OR L3- BLUE, NEUTRAL- WHITE/GRAY • SYSTEM RATING 13.200 kWDC 9.900 kWAC PHOTOVOLTAIC SYSTEM FIRE CLASSIFICATION LISTING IN ACCORDANCE WITH UL 1703 STANDARD. SHEET INDEX PV1 COVER PAGE PV2 SITE PLAN PV3 ROOF PLAN PV4 STRING LAYOUT & BOM PV5-PV6 ATTACHMENT DETAILS PV7 ELECTRICAL LINE & CALCS. PV8 SPECIFICATIONS & NOTES PV9-PV10 SIGNAGE PV11 JOB SAFETY PLAN PV12-PV21 EQUIPMENT SPECIFICATIONS PROJECT SITE HOUSE PHOTO SCALE: NTS PROJECT SITE VICINITY MAP SCALE: NTS SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (33) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) (33) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 13.200 kWDC AC SYSTEM SIZE: 9.900 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS VONDA L FRENCHRESIDENCE1032 W 13TH ST, PORT ANGELES, WA 98363, USAAPN.# : 0630000396350000DATE: 9/15/2022 SHEET NAME COVER PAGE SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-1 SITE NOTES A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS.• THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS AN UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES.• THE SOLAR PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS.• PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION [NEC 110.26]• LEGEND JB (N) JUNCTION BOX UM (E) UTILITY METER MSP (N) MAIN SERVICE PANEL PM (N) PRODUCTION METER IQ (N) ENPHASE IQ COMBINER AC (N) NON FUSED AC DISCONNECT VENT, ATTIC FAN (ROOF OBSTRUCTION) ROOF ATTACHMENT -------CONDUIT ENPHASE IQ8PLUS -72-2-US (240V) MICROINVERTER Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULES UNIRAC SOLARMOUNT LIGHT RAIL 168" MILL TRENCH SCALE: 1/16"= 1'-0" SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (33) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) (33) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 13.200 kWDC AC SYSTEM SIZE: 9.900 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS VONDA L FRENCHRESIDENCE1032 W 13TH ST, PORT ANGELES, WA 98363, USAAPN.# : 0630000396350000DATE: 9/15/2022 SHEET NAME SITE PLAN SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-2 DESIGN SPECIFICATION RISK CATEGORY:II CONSTRUCTION:SFD ZONING:RESIDENTIAL SNOW LOAD (ASCE7-16): 25 PSF EXPOSURE CATEGORY: C WIND SPEED (ASCE7-16): 126 MPH MODULE TYPE, DIMENSIONS & WEIGHT NUMBER OF MODULES: 33 MODULES MODULE TYPE:Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULE WEIGHT: 48.5 LBS MODULE DIMENSIONS: 74" X 41.1" = 21.12 SF UNIT WEIGHT OF AREA: 2.3 PSF ROOF DESCRIPTION ROOF ROOF TILT AZIMUTH TRUSS SIZE TRUSS SPACING ROOF MATERIAL #1 22° 121° 2" x 4" 24" o.c. COMP SHINGLE #2 22° 301° 2" x 4" 24" o.c. COMP SHINGLE ARRAY AREA & ROOF AREA CALC'S ROOF # OF MODULES ARRAY AREA (Sq. Ft.) #1 20 422.42 #2 13 274.58 (TOTAL ARRAY AREA/TOTAL ROOF AREA) X 100% = (696.99/1647.31) X 100% = 42.32% LEGEND JB (N) JUNCTION BOX UM (E) UTILITY METER MSP (N) MAIN SERVICE PANEL PM (N) PRODUCTION METER IQ (N) ENPHASE IQ COMBINER AC (N) NON FUSED AC DISCONNECT VENT, ATTIC FAN (ROOF OBSTRUCTION) ROOF ATTACHMENT -------CONDUIT ENPHASE IQ8PLUS -72-2-US (240V) MICROINVERTER Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULES UNIRAC SOLARMOUNT LIGHT RAIL 168" MILL TRENCH PANEL HEIGHT OFF ROOF 6" DEAD LOAD CALCULATION EQUIPMENT'S DESCRIPTIONS QTY LBS/UNIT TOTAL WEIGHT MODULES 33 48.5 1600.5 MID CLAMP 54 0.3 16.2 END CLAMP 24 0.31 7.44 UNIRAC SOLARMOUNT LIGHT RAIL 168" MILL 21 6.89 144.69 SPLICE BAR 14 0.65 9.1 RT-200-MINI BK2 79 0.5 39.50 TOTAL WEIGHT OF THE SYSTEM (LBS)1817.43 TOTAL ARRAY AREA ON THE ROOF (SQ. FT.) 696.99 WEIGHT PER SQ. FT. (LBS)2.61 WEIGHT PER PENETRATION (LBS)23.01 SCALE: 1/8"= 1'-0" SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (33) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) (33) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 13.200 kWDC AC SYSTEM SIZE: 9.900 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS VONDA L FRENCHRESIDENCE1032 W 13TH ST, PORT ANGELES, WA 98363, USAAPN.# : 0630000396350000DATE: 9/15/2022 SHEET NAME ROOF PLAN SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-3 SCALE: 1/8"= 1'-0" BILL OF MATERIALS EQUIPMENT QTY DESCRIPTION SOLAR PV MODULE 33 Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) INVERTER 33 ENPHASE IQ8PLUS -72-2-US (240V) JUNCTION BOX 1 JUNCTION BOX, NEMA 3R, UL LISTED IQ COMBINER BOX 1 ENPHASE IQ COMBINER 4C W/IQ GATEWAY (X-IQ-AM1-240-4C) PRODUCTION METER 1 PRODUCTION METER, 240V NON FUSED AC DISCONNECT 1 60A NON FUSED AC DISCONNECT, 240V, NEMA 3R, UL LISTED (KNIFE SWITCH) ATTACHMENT 79 RT-200-MINI BK2 ENPHASE Q CABLE 45 ENPHASE Q CABLE 204V (PER CONNECTOR) BRANCH TERMINATOR 3 BRANCH TERMINATOR IQ WATER TIGHT CAP 12 IQ WATER TIGHT CAPS CAP 24 RAIL END CAPS RAILS 21 UNIRAC SOLARMOUNT LIGHT RAIL 168" MILL BONDED SPLICE 14 SPLICE KIT MID CLAMP 54 UNIVERSAL SELF STANDING MID CLAMPS, UNIRAC, UNIVERSAL AESTHETIC FASTENER (UNIVERSAL-AF) MID CLAMP, 30-46MM, PREASSEMBLED INTEGRATED BONDING, DARK FINISH, QTY. 1, 302045D END CLAMP 24 CONCEALED UNIVERSAL END CLAMPS GROUNDING LUG 6 GROUNDING LUG A B C - MODULE STRINGING SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (33) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) (33) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 13.200 kWDC AC SYSTEM SIZE: 9.900 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS VONDA L FRENCHRESIDENCE1032 W 13TH ST, PORT ANGELES, WA 98363, USAAPN.# : 0630000396350000DATE: 9/15/2022 SHEET NAME STRING LAYOUT & BOM SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-4 SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (33) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) (33) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 13.200 kWDC AC SYSTEM SIZE: 9.900 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS VONDA L FRENCHRESIDENCE1032 W 13TH ST, PORT ANGELES, WA 98363, USAAPN.# : 0630000396350000DATE: 9/15/2022 SHEET NAME ATTACHMENT DETAILS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-5 SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (33) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) (33) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 13.200 kWDC AC SYSTEM SIZE: 9.900 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS VONDA L FRENCHRESIDENCE1032 W 13TH ST, PORT ANGELES, WA 98363, USAAPN.# : 0630000396350000DATE: 9/15/2022 SHEET NAME ATTACHMENT DETAILS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-6 ID TYPICAL INITIAL CONDUCTOR LOCATION FINAL CONDUCTOR LOCATION CONDUCTOR CONDUIT # OF PARALLEL CIRCUITS CURRENT-CARRYING CONDUCTORS IN CIRCUIT CONDUIT FILL PERCENT OCPD EGC TEMP. CORR. FACTOR CONDUIT FILL FACTOR CONT. CURRENT MAX. CURRENT BASE AMP. DERATED AMP. TERM. TEMP. RATING LENGTH VOTAGE DROP 1 3 ARRAY JUNCTION BOX 12 AWG Q CABLE COPPER - 1 2 N/A N/A 6 AWG BARE COPPER 0.82 (47°C)N/A 13.31A 16.64A N/A N/A 90°C 52FT 0.55% 2 1 JUNCTION BOX IQ COMBINER BOX 12 AWG THWN 2 COPPER MIN 0.75" DIA EMT 3 6 20.45%20A 6 AWG THWN-2 COPPER 1.04 (25°C)0.8 13.31A 16.64A 30A 24.96A 90°C 36FT 0.82% 3 1 IQ COMBINER BOX PRODUCTION METER 6 AWG THWN 2 COPPER MIN 0.75" DIA EMT 1 3 36.77%N/A 6 AWG THWN-2 COPPER 1.04 (25°C)1 39.93A 49.91A 75A 78.00A 90°C 5FT 0.08% 4 1 PRODUCTION METER NON FUSED AC DISCONNECT 6 AWG THWN 2 COPPER MIN 0.75" DIA EMT 1 3 36.77%N/A 6 AWG THWN-2 COPPER 1.04 (25°C)1 39.93A 49.91A 75A 78.00A 90°C 5FT 0.08% 5 1 NON FUSED AC DISCONNECT MSP 6 AWG THWN 2 COPPER MIN 0.75" DIA EMT 1 3 36.77%50A 6 AWG THWN-2 COPPER 1.04 (25°C)1 39.93A 49.91A 75A 78.00A 90°C 5FT 0.08% SCALE: NTS INTERCONNECTION 120% RULE - NEC 705.12(B)(2)(3)(b) UTILITY FEED + SOLAR BACKFEED 200A + 50A = 250A BUSS RATING X 120% 225A x 120% = 270A SERVICE INFO UTILITY PROVIDER:PORT ANGLES AHJ NAME:PORT ANGELES CITY MAIN SERVICE VOLTAGE:240V MAIN SERVICE PANEL:225 A MAIN BREAKER RATING:200 A MAIN SERVICE LOCATION:SOUTH SERVICE FEED SOURCE:OVERHEAD A SURGE PROTECTOR WILL BE ADDED TO PROPERLY PROTECT THE SENSITIVE ELECTRONICS PER NEC 2020 SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (33) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) (33) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 13.200 kWDC AC SYSTEM SIZE: 9.900 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS VONDA L FRENCHRESIDENCE1032 W 13TH ST, PORT ANGELES, WA 98363, USAAPN.# : 0630000396350000DATE: 9/15/2022 SHEET NAME ELECTRICAL LINE & CALCS. SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-7 SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) VMP 37.13 V IMP 10.77 A VOC 45.3 V ISC 11.14 A TEMP. COEFF. VOC -0.27%/K PTC RATING 376.55 W MODULE DIMENSION 74"(L) x 41.1"(W) PANEL WATTAGE 400 W INVERTER SPECIFICATIONS MANUFACTURER / MODEL ENPHASE IQ8PLUS -72-2-US (240V) MAX DC SHORT CIRCUIT CURRENT 15 A CONTINUOUS OUTPUT CURRENT 1.21 A AMBIENT TEMPERATURE SPECS RECORD LOW TEMP -6°C AMBIENT TEMP (HIGH TEMP 2%)25°C CONDUIT HEIGHT 7/8" ROOF TOP TEMP 90°C CONDUCTOR TEMPERATURE RATE 47°C MODULE TEMPERATURE COEFFICIENT OF VOC -0.27%/K PERCENT OF VALUES NUMBER OF CURRENT CARRYING CONDUCTORS IN EMT 0.80 4-6 0.70 7-9 0.50 10-20 VOLTAGE RISE IN Q CABLE FROM THE MICROINVERTERS TO THE JUNCTION BOX FOR BRANCH CIRCUIT #1 OF 11 IQ8PLUS MICROS, THE VOLTAGE RISE ON THE 240 VAC Q CABLE IS 0.55% FOR BRANCH CIRCUIT #2 OF 11 IQ8PLUS MICROS, THE VOLTAGE RISE ON THE 240 VAC Q CABLE IS 0.55% FOR BRANCH CIRCUIT #3 OF 11 IQ8PLUS MICROS, THE VOLTAGE RISE ON THE 240 VAC Q CABLE IS 0.55% VOLTAGE RISE FROM THE JUNCTION BOX TO THE IQ COMBINER BOX VRISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN FT.) = (1.21 AMP X 11) X (0.00205 OHMS/FT) X (36 FT X 2) = 13.31 AMPS X 0.00205 OHMS/FT) X 72 FT = 1.96 VOLTS %VRISE = 1.96 VOLTS ÷ 240 VOLTS = 0.82% THE VOLTAGE RISE FROM THE JUNCTION BOX TO THE IQ COMBINER BOX IS 0.82% VOLTAGE RISE FROM THE IQ COMBINER BOX TO THE PRODUCTION METER VRISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN FT.) = (1.21 AMP X 33) X (0.00051 OHMS/FT) X (5 FT X 2) = 39.93 AMPS X 0.00051 OHMS/FT) X 10 FT = 0.20 VOLTS %VRISE = 0.20 VOLTS ÷ 240 VOLTS = 0.08% THE VOLTAGE RISE FROM THE IQ COMBINER BOX TO THE PRODUCTION METER IS 0.08% VOLTAGE RISE FROM THE PRODUCTION METER TO THE NON FUSED AC DISCONNECT VRISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN FT.) = (1.21 AMP X 33) X (0.00051 OHMS/FT) X (5 FT X 2) = 39.93 AMPS X 0.00051 OHMS/FT) X 10 FT = 0.20 VOLTS %VRISE = 0.20 VOLTS ÷ 240 VOLTS = 0.08% THE VOLTAGE RISE FROM THE PRODUCTION METER TO THE NON FUSED AC DISCONNECT IS 0.08% VOLTAGE RISE FROM THE NON FUSED AC DISCONNECT TO THE MSP VRISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN FT.) = (1.21 AMP X 33) X (0.00051 OHMS/FT) X (5 FT X 2) = 39.93 AMPS X 0.00051 OHMS/FT) X 10 FT = 0.20 VOLTS %VRISE = 0.20 VOLTS ÷ 240 VOLTS = 0.08% THE VOLTAGE RISE FROM THE NON FUSED AC DISCONNECT TO THE MSP IS 0.08% TOTAL SYSTEM VOLTAGE RISE FOR ALL WIRE SECTIONS 0.55% + 0.82% + 0.08% + 0.08% + 0.08% = 1.61% SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (33) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) (33) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 13.200 kWDC AC SYSTEM SIZE: 9.900 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS VONDA L FRENCHRESIDENCE1032 W 13TH ST, PORT ANGELES, WA 98363, USAAPN.# : 0630000396350000DATE: 9/15/2022 SHEET NAME SPECIFICATIONS & NOTES SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-8 1 WARNING ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: POINT OF INTERCONNECTION, MAIN SERVICE DISCONNECT, AC DISCONNECT, AC COMBINER, INVERTER PER CODE: NEC 690.13(B) 2 CAUTION DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC LABEL LOCATION: MAIN SERVICE DISCONNECT/ AC DISCONNECT/ MAIN SERVICE PANEL/ REVENUE METER/ AC COMBINER PER CODE: NEC 705.12(C) 3 CAUTION : SOLAR ELECTRIC SYSTEM CONNECTED LABEL LOCATION: POINT OF INTERCONNECTION & INVERTER PER CODE: NEC 690.15 & 690.13(B) 4 SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE 'OFF' POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY LABEL LOCATION: MAIN SERVICE DISCONNECT IF MSD IS OUTSIDE PLACE IT THERE / IF MSD IS INSIDE PLACE ON THE AC DISCONNECT PER CODE: 2020 NEC 690.56(C) ADHESIVE FASTENED SIGNS THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED. • WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNING AND MARKINGS SHOULD COMPLY WITH ANSI 2535.4 [NEC 110.21(B) FIELD MARKING]. • ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT [IFC 605.11.1.3] • 5 PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH LABEL LOCATION: AC DISCONNECT PER CODE: NEC 690.56(C)(2) 6 PHOTOVOLTAIC AC DISCONNECT RATED AC OUTPUT CURRENT 39.93 AMPS NOMINAL OPERATING AC VOLTAGE 240 VOLTS LABEL LOCATION: INTERACTIVE SYSTEM POINT OF INTERCONNECTION PER CODE: NFPA 70, NEC 690.54 7 WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION: PLACE THIS LABEL AT P.O.C. TO SERVICE DISTRIBUTION EQUIPMENT (I.E. MAIN PANEL (AND SUBPANEL IF APPLICABLE)) PER CODE: NEC 705.12(B)(3)(2) 8 WARNING: PHOTOVOLTAIC POWER SOURCE LABEL LOCATION: CONDUIT PER CODE: NEC 690.31(D)(2) 9 CAUTION : SOLAR CIRCUIT LABEL LOCATION: MARKINGS PLACED ON ALL INTERIOR AND EXTERIOR CONDUIT, RACEWAYS, ENCLOSURES, AND CABLE ASSEMBLIES AT LEAST EVERY 1O FT, AT TURNS AND ABOVE/BELOW PENETRATIONS AND ALL COMBINER/JUNCTION BOXES PER CODE: IFC 606.11.1.4 10 WARNING - Electric Shock Hazard No user serviceable parts inside Contact authorized service provider for assistance LABEL LOCATION: INVERTER & JUNCTION BOXES (ROOF) PER CODE: NEC 690.13 (G)(3) & 690.13 (G)(4) SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (33) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) (33) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 13.200 kWDC AC SYSTEM SIZE: 9.900 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS VONDA L FRENCHRESIDENCE1032 W 13TH ST, PORT ANGELES, WA 98363, USAAPN.# : 0630000396350000DATE: 9/15/2022 SHEET NAME SIGNAGE SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-9 LABEL LOCATION: EACH SERVICE EQUIPMENT LOCATION AND AT THE LOCATION(S) OF THE SYSTEM DISCONNECT(S) FOR ALL ELECTRIC POWER PRODUCTION SOURCES CAPABLE OF BEING INTERCONNECTED (PER CODE: NEC 705.10) SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (33) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) (33) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 13.200 kWDC AC SYSTEM SIZE: 9.900 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS VONDA L FRENCHRESIDENCE1032 W 13TH ST, PORT ANGELES, WA 98363, USAAPN.# : 0630000396350000DATE: 9/15/2022 SHEET NAME SIGNAGE SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-10 SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (33) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) (33) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 13.200 kWDC AC SYSTEM SIZE: 9.900 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS VONDA L FRENCHRESIDENCE1032 W 13TH ST, PORT ANGELES, WA 98363, USAAPN.# : 0630000396350000DATE: 9/15/2022 SHEET NAME JOB SAFETY PLAN SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-11 SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (33) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) (33) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 13.200 kWDC AC SYSTEM SIZE: 9.900 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS VONDA L FRENCHRESIDENCE1032 W 13TH ST, PORT ANGELES, WA 98363, USAAPN.# : 0630000396350000DATE: 9/15/2022 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-12 SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (33) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) (33) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 13.200 kWDC AC SYSTEM SIZE: 9.900 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS VONDA L FRENCHRESIDENCE1032 W 13TH ST, PORT ANGELES, WA 98363, USAAPN.# : 0630000396350000DATE: 9/15/2022 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-13 SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (33) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) (33) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 13.200 kWDC AC SYSTEM SIZE: 9.900 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS VONDA L FRENCHRESIDENCE1032 W 13TH ST, PORT ANGELES, WA 98363, USAAPN.# : 0630000396350000DATE: 9/15/2022 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-14 SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (33) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) (33) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 13.200 kWDC AC SYSTEM SIZE: 9.900 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS VONDA L FRENCHRESIDENCE1032 W 13TH ST, PORT ANGELES, WA 98363, USAAPN.# : 0630000396350000DATE: 9/15/2022 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-15 SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (33) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) (33) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 13.200 kWDC AC SYSTEM SIZE: 9.900 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS VONDA L FRENCHRESIDENCE1032 W 13TH ST, PORT ANGELES, WA 98363, USAAPN.# : 0630000396350000DATE: 9/15/2022 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-16 SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (33) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) (33) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 13.200 kWDC AC SYSTEM SIZE: 9.900 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS VONDA L FRENCHRESIDENCE1032 W 13TH ST, PORT ANGELES, WA 98363, USAAPN.# : 0630000396350000DATE: 9/15/2022 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-17 SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (33) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) (33) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 13.200 kWDC AC SYSTEM SIZE: 9.900 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS VONDA L FRENCHRESIDENCE1032 W 13TH ST, PORT ANGELES, WA 98363, USAAPN.# : 0630000396350000DATE: 9/15/2022 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-18 SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (33) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) (33) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 13.200 kWDC AC SYSTEM SIZE: 9.900 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS VONDA L FRENCHRESIDENCE1032 W 13TH ST, PORT ANGELES, WA 98363, USAAPN.# : 0630000396350000DATE: 9/15/2022 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-19 SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (33) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) (33) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 13.200 kWDC AC SYSTEM SIZE: 9.900 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS VONDA L FRENCHRESIDENCE1032 W 13TH ST, PORT ANGELES, WA 98363, USAAPN.# : 0630000396350000DATE: 9/15/2022 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-20 SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (33) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) (33) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 13.200 kWDC AC SYSTEM SIZE: 9.900 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS VONDA L FRENCHRESIDENCE1032 W 13TH ST, PORT ANGELES, WA 98363, USAAPN.# : 0630000396350000DATE: 9/15/2022 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-21 PREPARED 11/22/22,14:41:53 PAYMENT DUE CITY OF PORT ANGELES PROGRAM BP820L --------------------------------------------------------------------------- APPLICATION NUMBER:22-00001471 1032 W 13TH ST FEE DESCRIPTION AMOUNT DUE --------------------------------------------------------------------------- ELECTRICAL ALTER RESIDENTIAL 240.00 TOTAL DUE 240.00 Please present reciept to the cashier with full payment SCOPE OF WORK TO INSTALL A ROOF MOUNTED SOLAR PHOTOVOLTAIC SYSTEM AT THE OWNER RESIDENCE LOCATED AT 1032 W 13TH ST, PORT ANGELES, WA 98363, USA. THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. THE PV SYSTEM DOES NOT INCLUDE STORAGE BATTERIES. EQUIPMENT SUMMARY 33 Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULES 33 ENPHASE IQ8PLUS -72-2-US (240V) MICROINVERTERS GENERAL NOTES THESE CONSTRUCTION DOCUMENTS HAVE BEEN BASED ON FIELD INSPECTIONS AND OTHER INFORMATION AVAILABLE AT THE TIME. ACTUAL FIELD CONDITIONS MAY REQUIRE MODIFICATIONS IN CONSTRUCTION DETAILS. • ARCHITECT HAS NOT BEEN RETAINED TO SUPERVISE ANY CONSTRUCTION OR INSTALLATION OF ANY EQUIPMENT AT SITE. • CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL, EQUIPMENT, TOOLS, OBTAINS ALL PERMITS, LICENSES AND PAY ALL REQUIRED FEES AND COMPLETE INSTALLATION. • CONTRACTOR HAS THE FULL RESPONSIBILITY TO CHECK AND VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS. ANY DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER BEFORE PROCEEDING WITH THE WORK. ANY WORK STARTED BEFORE CONSULTATION AND ACCEPTANCE BY THE ENGINEER SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE SUBJECT TO CORRECTION BY THEM WITHOUT ADDITIONAL COMPENSATION. • DAMAGE CAUSED TO THE EXISTING STRUCTURE, PIPES, DUCTS, WINDOWS, WALL, FLOORS, ETC. SHALL BE REPAIRED TO THE ORIGINAL CONDITION OR REPLACED BY THE CONTRACTOR AT NO ADDITIONAL COST. • THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR THE PROPER INSTALLATION AND COMPLETION OF THE WORK WITH APPROVED MATERIALS. • NO CHANGES ARE TO BE MADE WITHOUT THE CONSULTATION AND APPROVAL OF THE ARCHITECT. • CONTRACTOR SHALL OBTAIN BULDING PERMIT. NO WORK TO START UNLESS BUILDING PERMIT IS PROPERLY DISPLAYED. • ALL WORKMANSHIP AND MATERIALS SHALL BE OF FIRST QUALITY AND IN COMPLIANCE WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE, THE DEPARTMENT OF ENVIRONMENTAL PROTECTION AND ALL PERTINENT AGENCIES. • IT 1S ESSENTIAL THAT ALL WORK PROCEED WITH THE MAXIMUM COOPERATION OF ALL PARTIES AND WITH MINIMUM INTERFERENCE TO THE OCCUPANTS WITHIN THE BUILDING. THE OWNER'S DIRECTIONS IN THIS REGARD SHALL BE FULLY COMPLIED WITH. • ALL EXPOSED PLUMBING, HVAC, ELECTRICAL DUCTWORK, PIPING AND CONDUITS ARE TO BE PAINTED BY GENERAL CONTRACTOR. • THE CONTRACTOR SHALL PERFORM THE WORK IN STRICT CONFORMANCE WITH THE LOCAL LAWS, REGULATIONS AND THE NATIONAL ELECTRIC CODE. • THE CONTRACTOR SHALL OBTAIN ALL PERMITS, APPROVALS, AFFIDAVITS, CERTIFICATIONS, ETC. AND PAY ALL FEES AS REQUIRED BY THE LOCAL AUTHORITIES. • CONTRACTORS SHALL OBTAIN FIRE CERTIF. UPON COMPLETION OF WORK.• ELECTRICAL NOTES ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION.• ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. • WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. • WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. • WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. • ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE.• MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURERS INSTRUCTION. • MODULE SUPPORT RAIL SHALL BE BONDED TO THE MODULE• GOVERNING CODES 2020 NATIONAL ELECTRICAL CODE 2018 INTERNATIONAL FIRE CODE 2018 INTERNATIONAL BUILDING CODE 2018 INTERNATIONAL RESIDENTIAL CODE WASHINGTON ADMINISTRATIVE CODE (WAC) AHJ NAME : PORT ANGELES CITY WIRING AND CONDUIT NOTES ALL CONDUIT SIZES AND TYPES SHALL BE LISTED FOR ITS PURPOSE AND APPROVAL FOR THE SITE APPLICATIONS • ALL PV CABLES AND HOMERUN WIRES BE #10AWG *USE-2, PV WIRE, OR PROPRIETARY SOLAR CABLING SPECIFIED BY MFR, OR EQUIVALENT; ROUTED TO SOURCE CIRCUIT COMBINER BOXES AS REQUIRED • ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE DERATED ACCORDING TO AS PER LATEST NEC CODE. • EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2, 90°C RATED, WET AND UV RESISTANT, AND UL LISTED RATED FOR 600V, UV RATED SPIRAL WRAP SHALL BE USED TO PROTECT WIRE FROM SHARP EDGES • PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED THHN/THWN-2 INSULATED, 90°C RATED, WET AND UV RESISTANT, RATED FOR 1000V PER NEC 2017 • 4-WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH THE HIGHER VOLTAGE TO GROUND MARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE MEANS • ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION• VOLTAGE DROP LIMITED TO 2%• AC CONDUCTORS >4AWG COLOR CODED OR MARKED: PHASE A OR L1- BLACK, PHASE B OR L2- RED, PHASE C OR L3- BLUE, NEUTRAL- WHITE/GRAY • VOLTAGE DROP LIMITED TO 2%• AC CONDUCTORS >4AWG COLOR CODED OR MARKED: PHASE AOR L1- BLACK, PHASE B OR L2- RED, PHASE C OR L3- BLUE, NEUTRAL- WHITE/GRAY • SYSTEM RATING 13.200 kWDC 9.900 kWAC PHOTOVOLTAIC SYSTEM FIRE CLASSIFICATION LISTING IN ACCORDANCE WITH UL 1703 STANDARD. SHEET INDEX PV1 COVER PAGE PV2 SITE PLAN PV3 ROOF PLAN PV4 STRING LAYOUT & BOM PV5-PV6 ATTACHMENT DETAILS PV7 ELECTRICAL LINE & CALCS. PV8 SPECIFICATIONS & NOTES PV9-PV10 SIGNAGE PV11 JOB SAFETY PLAN PV12-PV21 EQUIPMENT SPECIFICATIONS PROJECT SITE HOUSE PHOTO SCALE: NTS PROJECT SITE VICINITY MAP SCALE: NTS SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (33) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) (33) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 13.200 kWDC AC SYSTEM SIZE: 9.900 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS VONDA L FRENCHRESIDENCE1032 W 13TH ST, PORT ANGELES, WA 98363, USAAPN.# : 0630000396350000DATE: 9/15/2022 SHEET NAME COVER PAGE SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-1 SITE NOTES A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS.• THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS AN UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES.• THE SOLAR PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS.• PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION [NEC 110.26]• LEGEND JB (N) JUNCTION BOX UM (E) UTILITY METER MSP (N) MAIN SERVICE PANEL PM (N) PRODUCTION METER IQ (N) ENPHASE IQ COMBINER AC (N) NON FUSED AC DISCONNECT VENT, ATTIC FAN (ROOF OBSTRUCTION) ROOF ATTACHMENT -------CONDUIT ENPHASE IQ8PLUS -72-2-US (240V) MICROINVERTER Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULES UNIRAC SOLARMOUNT LIGHT RAIL 168" MILL TRENCH SCALE: 1/16"= 1'-0" SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (33) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) (33) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 13.200 kWDC AC SYSTEM SIZE: 9.900 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS VONDA L FRENCHRESIDENCE1032 W 13TH ST, PORT ANGELES, WA 98363, USAAPN.# : 0630000396350000DATE: 9/15/2022 SHEET NAME SITE PLAN SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-2 DESIGN SPECIFICATION RISK CATEGORY:II CONSTRUCTION:SFD ZONING:RESIDENTIAL SNOW LOAD (ASCE7-16): 25 PSF EXPOSURE CATEGORY: C WIND SPEED (ASCE7-16): 126 MPH MODULE TYPE, DIMENSIONS & WEIGHT NUMBER OF MODULES: 33 MODULES MODULE TYPE:Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULE WEIGHT: 48.5 LBS MODULE DIMENSIONS: 74" X 41.1" = 21.12 SF UNIT WEIGHT OF AREA: 2.3 PSF ROOF DESCRIPTION ROOF ROOF TILT AZIMUTH TRUSS SIZE TRUSS SPACING ROOF MATERIAL #1 22° 121° 2" x 4" 24" o.c. COMP SHINGLE #2 22° 301° 2" x 4" 24" o.c. COMP SHINGLE ARRAY AREA & ROOF AREA CALC'S ROOF # OF MODULES ARRAY AREA (Sq. Ft.) #1 20 422.42 #2 13 274.58 (TOTAL ARRAY AREA/TOTAL ROOF AREA) X 100% = (696.99/1647.31) X 100% = 42.32% LEGEND JB (N) JUNCTION BOX UM (E) UTILITY METER MSP (N) MAIN SERVICE PANEL PM (N) PRODUCTION METER IQ (N) ENPHASE IQ COMBINER AC (N) NON FUSED AC DISCONNECT VENT, ATTIC FAN (ROOF OBSTRUCTION) ROOF ATTACHMENT -------CONDUIT ENPHASE IQ8PLUS -72-2-US (240V) MICROINVERTER Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULES UNIRAC SOLARMOUNT LIGHT RAIL 168" MILL TRENCH PANEL HEIGHT OFF ROOF 6" DEAD LOAD CALCULATION EQUIPMENT'S DESCRIPTIONS QTY LBS/UNIT TOTAL WEIGHT MODULES 33 48.5 1600.5 MID CLAMP 54 0.3 16.2 END CLAMP 24 0.31 7.44 UNIRAC SOLARMOUNT LIGHT RAIL 168" MILL 21 6.89 144.69 SPLICE BAR 14 0.65 9.1 RT-200-MINI BK2 79 0.5 39.50 TOTAL WEIGHT OF THE SYSTEM (LBS)1817.43 TOTAL ARRAY AREA ON THE ROOF (SQ. FT.) 696.99 WEIGHT PER SQ. FT. (LBS)2.61 WEIGHT PER PENETRATION (LBS)23.01 SCALE: 1/8"= 1'-0" SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (33) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) (33) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 13.200 kWDC AC SYSTEM SIZE: 9.900 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS VONDA L FRENCHRESIDENCE1032 W 13TH ST, PORT ANGELES, WA 98363, USAAPN.# : 0630000396350000DATE: 9/15/2022 SHEET NAME ROOF PLAN SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-3 SCALE: 1/8"= 1'-0" BILL OF MATERIALS EQUIPMENT QTY DESCRIPTION SOLAR PV MODULE 33 Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) INVERTER 33 ENPHASE IQ8PLUS -72-2-US (240V) JUNCTION BOX 1 JUNCTION BOX, NEMA 3R, UL LISTED IQ COMBINER BOX 1 ENPHASE IQ COMBINER 4C W/IQ GATEWAY (X-IQ-AM1-240-4C) PRODUCTION METER 1 PRODUCTION METER, 240V NON FUSED AC DISCONNECT 1 60A NON FUSED AC DISCONNECT, 240V, NEMA 3R, UL LISTED (KNIFE SWITCH) ATTACHMENT 79 RT-200-MINI BK2 ENPHASE Q CABLE 45 ENPHASE Q CABLE 204V (PER CONNECTOR) BRANCH TERMINATOR 3 BRANCH TERMINATOR IQ WATER TIGHT CAP 12 IQ WATER TIGHT CAPS CAP 24 RAIL END CAPS RAILS 21 UNIRAC SOLARMOUNT LIGHT RAIL 168" MILL BONDED SPLICE 14 SPLICE KIT MID CLAMP 54 UNIVERSAL SELF STANDING MID CLAMPS, UNIRAC, UNIVERSAL AESTHETIC FASTENER (UNIVERSAL-AF) MID CLAMP, 30-46MM, PREASSEMBLED INTEGRATED BONDING, DARK FINISH, QTY. 1, 302045D END CLAMP 24 CONCEALED UNIVERSAL END CLAMPS GROUNDING LUG 6 GROUNDING LUG A B C - MODULE STRINGING SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (33) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) (33) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 13.200 kWDC AC SYSTEM SIZE: 9.900 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS VONDA L FRENCHRESIDENCE1032 W 13TH ST, PORT ANGELES, WA 98363, USAAPN.# : 0630000396350000DATE: 9/15/2022 SHEET NAME STRING LAYOUT & BOM SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-4 SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (33) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) (33) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 13.200 kWDC AC SYSTEM SIZE: 9.900 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS VONDA L FRENCHRESIDENCE1032 W 13TH ST, PORT ANGELES, WA 98363, USAAPN.# : 0630000396350000DATE: 9/15/2022 SHEET NAME ATTACHMENT DETAILS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-5 SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (33) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) (33) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 13.200 kWDC AC SYSTEM SIZE: 9.900 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS VONDA L FRENCHRESIDENCE1032 W 13TH ST, PORT ANGELES, WA 98363, USAAPN.# : 0630000396350000DATE: 9/15/2022 SHEET NAME ATTACHMENT DETAILS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-6 ID TYPICAL INITIAL CONDUCTOR LOCATION FINAL CONDUCTOR LOCATION CONDUCTOR CONDUIT # OF PARALLEL CIRCUITS CURRENT-CARRYING CONDUCTORS IN CIRCUIT CONDUIT FILL PERCENT OCPD EGC TEMP. CORR. FACTOR CONDUIT FILL FACTOR CONT. CURRENT MAX. CURRENT BASE AMP. DERATED AMP. TERM. TEMP. RATING LENGTH VOTAGE DROP 1 3 ARRAY JUNCTION BOX 12 AWG Q CABLE COPPER - 1 2 N/A N/A 6 AWG BARE COPPER 0.82 (47°C)N/A 13.31A 16.64A N/A N/A 90°C 52FT 0.55% 2 1 JUNCTION BOX IQ COMBINER BOX 12 AWG THWN 2 COPPER MIN 0.75" DIA EMT 3 6 20.45%20A 6 AWG THWN-2 COPPER 1.04 (25°C)0.8 13.31A 16.64A 30A 24.96A 90°C 36FT 0.82% 3 1 IQ COMBINER BOX PRODUCTION METER 6 AWG THWN 2 COPPER MIN 0.75" DIA EMT 1 3 36.77%N/A 6 AWG THWN-2 COPPER 1.04 (25°C)1 39.93A 49.91A 75A 78.00A 90°C 5FT 0.08% 4 1 PRODUCTION METER NON FUSED AC DISCONNECT 6 AWG THWN 2 COPPER MIN 0.75" DIA EMT 1 3 36.77%N/A 6 AWG THWN-2 COPPER 1.04 (25°C)1 39.93A 49.91A 75A 78.00A 90°C 5FT 0.08% 5 1 NON FUSED AC DISCONNECT MSP 6 AWG THWN 2 COPPER MIN 0.75" DIA EMT 1 3 36.77%50A 6 AWG THWN-2 COPPER 1.04 (25°C)1 39.93A 49.91A 75A 78.00A 90°C 5FT 0.08% SCALE: NTS INTERCONNECTION 120% RULE - NEC 705.12(B)(2)(3)(b) UTILITY FEED + SOLAR BACKFEED 200A + 50A = 250A BUSS RATING X 120% 225A x 120% = 270A SERVICE INFO UTILITY PROVIDER:PORT ANGLES AHJ NAME:PORT ANGELES CITY MAIN SERVICE VOLTAGE:240V MAIN SERVICE PANEL:225 A MAIN BREAKER RATING:200 A MAIN SERVICE LOCATION:SOUTH SERVICE FEED SOURCE:OVERHEAD A SURGE PROTECTOR WILL BE ADDED TO PROPERLY PROTECT THE SENSITIVE ELECTRONICS PER NEC 2020 SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (33) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) (33) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 13.200 kWDC AC SYSTEM SIZE: 9.900 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS VONDA L FRENCHRESIDENCE1032 W 13TH ST, PORT ANGELES, WA 98363, USAAPN.# : 0630000396350000DATE: 9/15/2022 SHEET NAME ELECTRICAL LINE & CALCS. SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-7 SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) VMP 37.13 V IMP 10.77 A VOC 45.3 V ISC 11.14 A TEMP. COEFF. VOC -0.27%/K PTC RATING 376.55 W MODULE DIMENSION 74"(L) x 41.1"(W) PANEL WATTAGE 400 W INVERTER SPECIFICATIONS MANUFACTURER / MODEL ENPHASE IQ8PLUS -72-2-US (240V) MAX DC SHORT CIRCUIT CURRENT 15 A CONTINUOUS OUTPUT CURRENT 1.21 A AMBIENT TEMPERATURE SPECS RECORD LOW TEMP -6°C AMBIENT TEMP (HIGH TEMP 2%)25°C CONDUIT HEIGHT 7/8" ROOF TOP TEMP 90°C CONDUCTOR TEMPERATURE RATE 47°C MODULE TEMPERATURE COEFFICIENT OF VOC -0.27%/K PERCENT OF VALUES NUMBER OF CURRENT CARRYING CONDUCTORS IN EMT 0.80 4-6 0.70 7-9 0.50 10-20 VOLTAGE RISE IN Q CABLE FROM THE MICROINVERTERS TO THE JUNCTION BOX FOR BRANCH CIRCUIT #1 OF 11 IQ8PLUS MICROS, THE VOLTAGE RISE ON THE 240 VAC Q CABLE IS 0.55% FOR BRANCH CIRCUIT #2 OF 11 IQ8PLUS MICROS, THE VOLTAGE RISE ON THE 240 VAC Q CABLE IS 0.55% FOR BRANCH CIRCUIT #3 OF 11 IQ8PLUS MICROS, THE VOLTAGE RISE ON THE 240 VAC Q CABLE IS 0.55% VOLTAGE RISE FROM THE JUNCTION BOX TO THE IQ COMBINER BOX VRISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN FT.) = (1.21 AMP X 11) X (0.00205 OHMS/FT) X (36 FT X 2) = 13.31 AMPS X 0.00205 OHMS/FT) X 72 FT = 1.96 VOLTS %VRISE = 1.96 VOLTS ÷ 240 VOLTS = 0.82% THE VOLTAGE RISE FROM THE JUNCTION BOX TO THE IQ COMBINER BOX IS 0.82% VOLTAGE RISE FROM THE IQ COMBINER BOX TO THE PRODUCTION METER VRISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN FT.) = (1.21 AMP X 33) X (0.00051 OHMS/FT) X (5 FT X 2) = 39.93 AMPS X 0.00051 OHMS/FT) X 10 FT = 0.20 VOLTS %VRISE = 0.20 VOLTS ÷ 240 VOLTS = 0.08% THE VOLTAGE RISE FROM THE IQ COMBINER BOX TO THE PRODUCTION METER IS 0.08% VOLTAGE RISE FROM THE PRODUCTION METER TO THE NON FUSED AC DISCONNECT VRISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN FT.) = (1.21 AMP X 33) X (0.00051 OHMS/FT) X (5 FT X 2) = 39.93 AMPS X 0.00051 OHMS/FT) X 10 FT = 0.20 VOLTS %VRISE = 0.20 VOLTS ÷ 240 VOLTS = 0.08% THE VOLTAGE RISE FROM THE PRODUCTION METER TO THE NON FUSED AC DISCONNECT IS 0.08% VOLTAGE RISE FROM THE NON FUSED AC DISCONNECT TO THE MSP VRISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN FT.) = (1.21 AMP X 33) X (0.00051 OHMS/FT) X (5 FT X 2) = 39.93 AMPS X 0.00051 OHMS/FT) X 10 FT = 0.20 VOLTS %VRISE = 0.20 VOLTS ÷ 240 VOLTS = 0.08% THE VOLTAGE RISE FROM THE NON FUSED AC DISCONNECT TO THE MSP IS 0.08% TOTAL SYSTEM VOLTAGE RISE FOR ALL WIRE SECTIONS 0.55% + 0.82% + 0.08% + 0.08% + 0.08% = 1.61% SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (33) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) (33) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 13.200 kWDC AC SYSTEM SIZE: 9.900 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS VONDA L FRENCHRESIDENCE1032 W 13TH ST, PORT ANGELES, WA 98363, USAAPN.# : 0630000396350000DATE: 9/15/2022 SHEET NAME SPECIFICATIONS & NOTES SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-8 1 WARNING ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: POINT OF INTERCONNECTION, MAIN SERVICE DISCONNECT, AC DISCONNECT, AC COMBINER, INVERTER PER CODE: NEC 690.13(B) 2 CAUTION DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC LABEL LOCATION: MAIN SERVICE DISCONNECT/ AC DISCONNECT/ MAIN SERVICE PANEL/ REVENUE METER/ AC COMBINER PER CODE: NEC 705.12(C) 3 CAUTION : SOLAR ELECTRIC SYSTEM CONNECTED LABEL LOCATION: POINT OF INTERCONNECTION & INVERTER PER CODE: NEC 690.15 & 690.13(B) 4 SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE 'OFF' POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY LABEL LOCATION: MAIN SERVICE DISCONNECT IF MSD IS OUTSIDE PLACE IT THERE / IF MSD IS INSIDE PLACE ON THE AC DISCONNECT PER CODE: 2020 NEC 690.56(C) ADHESIVE FASTENED SIGNS THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED. • WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNING AND MARKINGS SHOULD COMPLY WITH ANSI 2535.4 [NEC 110.21(B) FIELD MARKING]. • ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT [IFC 605.11.1.3] • 5 PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH LABEL LOCATION: AC DISCONNECT PER CODE: NEC 690.56(C)(2) 6 PHOTOVOLTAIC AC DISCONNECT RATED AC OUTPUT CURRENT 39.93 AMPS NOMINAL OPERATING AC VOLTAGE 240 VOLTS LABEL LOCATION: INTERACTIVE SYSTEM POINT OF INTERCONNECTION PER CODE: NFPA 70, NEC 690.54 7 WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION: PLACE THIS LABEL AT P.O.C. TO SERVICE DISTRIBUTION EQUIPMENT (I.E. MAIN PANEL (AND SUBPANEL IF APPLICABLE)) PER CODE: NEC 705.12(B)(3)(2) 8 WARNING: PHOTOVOLTAIC POWER SOURCE LABEL LOCATION: CONDUIT PER CODE: NEC 690.31(D)(2) 9 CAUTION : SOLAR CIRCUIT LABEL LOCATION: MARKINGS PLACED ON ALL INTERIOR AND EXTERIOR CONDUIT, RACEWAYS, ENCLOSURES, AND CABLE ASSEMBLIES AT LEAST EVERY 1O FT, AT TURNS AND ABOVE/BELOW PENETRATIONS AND ALL COMBINER/JUNCTION BOXES PER CODE: IFC 606.11.1.4 10 WARNING - Electric Shock Hazard No user serviceable parts inside Contact authorized service provider for assistance LABEL LOCATION: INVERTER & JUNCTION BOXES (ROOF) PER CODE: NEC 690.13 (G)(3) & 690.13 (G)(4) SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (33) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) (33) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 13.200 kWDC AC SYSTEM SIZE: 9.900 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS VONDA L FRENCHRESIDENCE1032 W 13TH ST, PORT ANGELES, WA 98363, USAAPN.# : 0630000396350000DATE: 9/15/2022 SHEET NAME SIGNAGE SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-9 LABEL LOCATION: EACH SERVICE EQUIPMENT LOCATION AND AT THE LOCATION(S) OF THE SYSTEM DISCONNECT(S) FOR ALL ELECTRIC POWER PRODUCTION SOURCES CAPABLE OF BEING INTERCONNECTED (PER CODE: NEC 705.10) SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (33) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) (33) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 13.200 kWDC AC SYSTEM SIZE: 9.900 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS VONDA L FRENCHRESIDENCE1032 W 13TH ST, PORT ANGELES, WA 98363, USAAPN.# : 0630000396350000DATE: 9/15/2022 SHEET NAME SIGNAGE SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-10 SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (33) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) (33) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 13.200 kWDC AC SYSTEM SIZE: 9.900 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS VONDA L FRENCHRESIDENCE1032 W 13TH ST, PORT ANGELES, WA 98363, USAAPN.# : 0630000396350000DATE: 9/15/2022 SHEET NAME JOB SAFETY PLAN SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-11 SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (33) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) (33) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 13.200 kWDC AC SYSTEM SIZE: 9.900 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS VONDA L FRENCHRESIDENCE1032 W 13TH ST, PORT ANGELES, WA 98363, USAAPN.# : 0630000396350000DATE: 9/15/2022 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-12 SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (33) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) (33) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 13.200 kWDC AC SYSTEM SIZE: 9.900 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS VONDA L FRENCHRESIDENCE1032 W 13TH ST, PORT ANGELES, WA 98363, USAAPN.# : 0630000396350000DATE: 9/15/2022 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-13 SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (33) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) (33) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 13.200 kWDC AC SYSTEM SIZE: 9.900 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS VONDA L FRENCHRESIDENCE1032 W 13TH ST, PORT ANGELES, WA 98363, USAAPN.# : 0630000396350000DATE: 9/15/2022 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-14 SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (33) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) (33) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 13.200 kWDC AC SYSTEM SIZE: 9.900 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS VONDA L FRENCHRESIDENCE1032 W 13TH ST, PORT ANGELES, WA 98363, USAAPN.# : 0630000396350000DATE: 9/15/2022 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-15 SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (33) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) (33) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 13.200 kWDC AC SYSTEM SIZE: 9.900 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS VONDA L FRENCHRESIDENCE1032 W 13TH ST, PORT ANGELES, WA 98363, USAAPN.# : 0630000396350000DATE: 9/15/2022 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-16 SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (33) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) (33) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 13.200 kWDC AC SYSTEM SIZE: 9.900 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS VONDA L FRENCHRESIDENCE1032 W 13TH ST, PORT ANGELES, WA 98363, USAAPN.# : 0630000396350000DATE: 9/15/2022 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-17 SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (33) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) (33) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 13.200 kWDC AC SYSTEM SIZE: 9.900 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS VONDA L FRENCHRESIDENCE1032 W 13TH ST, PORT ANGELES, WA 98363, USAAPN.# : 0630000396350000DATE: 9/15/2022 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-18 SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (33) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) (33) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 13.200 kWDC AC SYSTEM SIZE: 9.900 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS VONDA L FRENCHRESIDENCE1032 W 13TH ST, PORT ANGELES, WA 98363, USAAPN.# : 0630000396350000DATE: 9/15/2022 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-19 SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (33) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) (33) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 13.200 kWDC AC SYSTEM SIZE: 9.900 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS VONDA L FRENCHRESIDENCE1032 W 13TH ST, PORT ANGELES, WA 98363, USAAPN.# : 0630000396350000DATE: 9/15/2022 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-20 SMART ENERGY TODAY (SET) 1550 DIGITAL DR, LEHI, UT 84043, USA SYSTEM INFO (33) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) (33) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 13.200 kWDC AC SYSTEM SIZE: 9.900 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS VONDA L FRENCHRESIDENCE1032 W 13TH ST, PORT ANGELES, WA 98363, USAAPN.# : 0630000396350000DATE: 9/15/2022 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-21 ELECTRICAL INSPECTION WIRING REPORT APPROVED NOT APPROVED DITCH ROUGH IN/COVER SERVICE FINAL COMMENTS: PV system NOTIFY INSPECTOR at (360) 808-2613 WHEN CORRECTIONS ARE COMPLETED WITHIN 15 DAYS DATE PERMIT # INSPECTOR 12/12/2022 22-1471 TAP OWNER CONTRACTOR Lumio PROJECT ADDRESS 1032 W 13th St