HomeMy WebLinkAbout4217 Fairmount Ave - Engineering s ~~ CITY OF PORT ANGELES PUBLIC WORKS - BUILDING DMSION 321 EAST 5TH STREET, PORT ANGELES, WA 98362 PUBILlC WORKS & R/W PERMIT D Attached Notes OWNER/APPLICANT DENA CRANE 4217 FAIRMOUNT Port Angeles, WA 98363 000/604-7903 PROJECT INFO Work is Plans Required Contractor' Performance Bond Required Proof of Insurance Work to Perform Issued 12/05/2001 Permit No Work Order' 1227 o Value Work. $000 PROPERTY LOCATION 4217 FAIRMOUNT AVE Lot: 11-13 Subdivision PENN PARK Parcel No 063008581460000 Block: 14 D Long Legal Start Date. Amount: I I Finish Date. 0001000-0000 $000 D Misc IZI Install D Repair D Watermain IZI Sanitary Sewer D Storm Drain D Underground Tele/Elec PROJECT NOTES CONNECT INTO SANITARY SEWER IN GLENWOOD NO CHARGE FOR CONNECTION CUSTOMER HAS BEEN PAYING SAN. SEWER CHARGES RIGHT OF WAY PERMIT AND RESTORATION ONLY TO BE CHARGED I I RECEIPT#8584 FEES ASSESSMENT- 1 ) R/W Excav' 2.) Sidewalk. 3 ) Curb/Gutter' 4 ) Driveway' 5 ) Dwy Culvert: 6 ) Street Cut: 7 ) Other R/W 8 ) Fire Hydrant: 9) Res Water Servo 10) Comm Water Servo 11 ) Other Water Service 12.)Water System Dev' 13 ) San Sewer SFR 14 ) San Sewer MFR add unit: 0 $45 00 $000 $000 $000 $000 $230 00 $000 $000 $000 $000 $000 $000 $000 $000 Receipt No Inspection Fee RW SANITARY g'5M $000 WATER 15 ) Other San Sewer' 16) Sew Tap Wye/Man Tap 17 ) Sew Capl W 1M Removal 18.) Alter Repair Sewer' 19 ) Storm Drain. 20) Catch Basin per ea. 21 ) Sewer System Dev' 22.) Milwaukee Dr Sew Ass 23 ) R/W Use Perm 24 ) Admin Cost (0 RA) 25 ) 0 RA. 26 ) Misc: TOTAL FEE. Amount Paid $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $275.00 $275 00 Balance Due. DWY STORM DRA $0.00 OTHER Separate Permits are required for electrical work, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Sionature of Contractor or Authorized Aoent Date Date Sianature of Owner (if owner is builderl CITY OF PORT ANGELES DEPARTMENT dF PUBLIC WORKS . . . . . . INSPECT"ION REPORT. . . REQUEST Date Time Received by (phone, person) 1t/7 r~ location of Work to be inspected Name of person requesting inspection Address of person requesting inspection ~. e of I:nspection (circle appropriate one) ~~oundation Framing Chimney Phone No Permit No Plumbing Final Sewer Excav Other /Z2-7 Inspected Remarks Time INSPECTION NOTES / Date P 0'\ ByC-1A k/ RESTORATION REQUIRED NO YES X j t+ ~ I~ I ~.o. \ ,1 t I I \l 1 t .L. ~ <.J -., \)...... b<' ~ ,'::" ..:-.--------- \" "- --. K::; Q --- ~-- -------.._-".'--.~.~..._,.... '() -- -ll r;-;;~-:#-:-d- c' '" t,... ( I.' ,~ r-\ / vi- ..(-<' '" l> " U" \;>1 -'(e\~ \ ",e-'< 1 ~o- I pt) cY--- ~ /75 SURFACE RESTORATION ( 3 .K b ) SURFACE TYPE 0 Unimproved D Gravel [KJ Asphalt D pce o Repaired by City [] Repaired by Permittee [] No Damage Found /6S!rpef I ~hMo, (Cohtinue re erse side if necessary) I D Other Work Order # ~ COMPlETE~ D INCOMPLETE -(~ $ - <6-0 '2- rr STREET SUPERINTENDENT (DATE) MEMO PUBLIC WORKS & UTILITIES DEPARTMENT Glenn A. Cutler Director [4801] Phyllis Rasler Administrative Assistant [4800] Cate Rinehart Administrative Assistant [4700] Ken Ridout Deputy Director [4802] Gary Kenworthy Deputy Director and City Engineer [4803] Scott McLain Deputy Director [4703] Jim Harper Electrical Engineering Mgr [4702] Larry Dunbar Power Resources Mgr [4710] Doyle McGinley Water Wastewater Collection Superintendent [4855] Pete Burrett Equipment Services Superintendent [4835] Dave Ireland Light Operations Manager [4731] Jeff D Young Treat. Plant Superintendent [4845] Tom McCabe Solid Waste Superintendent [4872] Steve Evans Landfill Supervisor [4873] Mike Horton Street Maintenance Supervisor [4825] ~ORTANGELES WAS H I N G TON, USA DATE 12/11/01 TO FILE 4217 F AIRMOUNT AVE. FROM. WAYNE GROFF RE SEWER HOOK-UP I arnved on SIte at approXImately 1.30 Upon amval I notIced a metal structure about 3 5 feet m dIameter WhICh was level wIth the surface of the ground and full of sewer water It appeared to be a failed septIc tank. The contractor had a dItch 7 5 feet deep and 3 feet WIde that exposed the mam. The dItch was dug at the pomt that had been located by a City crew that accordmg to the map should have been an eXIstmg wye. There was not a wye at thIS locatIOn. I mstructed the contractor that Ifhe was tofnter the dItch agam, he would eIther have to put shonng m or relIeve the SIdes of the dItch at a one to one startmg,four feet up from the bottom of the dItch. He agreed to relIeve the SIdes. Upon relIevmg the east SIde of the dItch, a slIce of matenal fell off exposmg an eXIstmg 6" concrete pIpe about 3' east of the dItch SIde The pIpe headed m the general dIrectIOn of the reSIdence at 4217 FamTIount Ave. Not knowmg the mtegnty of the 6" concrete pIpe, I mstructed t~~~tractor to tap the mam sewer lIne and connect the new 6" PVC lIne to the saddle He~o and backfilled the hole about half way WIth pea gravel then filled and compacted the remamder of the hole WIth crushed rock. ~ /L~ WA~F INSPECTOR CITY OF PORT ANGELES BUILDING PERMIT INSPECTION RECORD CALL 417-4815 FOR BUILDING INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLA WFUL TO COllER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED COMMENTS YES I NO FOUNDATION: FOOTINGS WALLS FOUNDATION DRAINAGE ELECTRICAL (LIGHT DEFT) ROUGH-IN I PLUMBING UNDER FLOOR I SLAB ROUGH-IN WATERLINE BACK FLOW I WATER AIR SEAL WALLS CEILING I FRAMING JOISTS I GIRDERS SHEAR WALL WALLS I ROOF I CEILING DRYWALL T-BAR INSULATION SLAB WALL I FLOOR I CEILING I MECHANICAL CHIMNEY WooDSTOVE I PELLET DUCTS PW UTILITIES I SITE WORK (Engineering Division) WATERLINE I METER SEWER CONNECTION SANITARY STORM SITE DRAINAGE I EROSION CONTROL PARKING OTIlER FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCYIUSE RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED YES NO ELECTRICAL LIGHT DEPT 417-4746 ELECTRICAL LIGHT DEPT CONSTRUCTIONR.W IPWI CONSTRUCTION R. W ENGINEERING 417-4807 PW I ENGINEERING FIRE (MUL TI-F AM. ONLY) 417-4654 FIRE DEPT BUILDING 417-4815 BUILDING GENERAL COMMENTS: PW-1l02.15 (4196]