Loading...
HomeMy WebLinkAbout204 W 7TH ST - Building (2)ELECTRICAL PERMIT CITY OF PORT ANGELES 360-417-4735 Application Number . . . . . 18-00000454 Date 4/02/18 Application pin number . . . 691794 Property Address . . . . . . 204 W 7TH ST ASSESSOR PARCEL NUMBER: 06 -30 -00 -0 -2 -3300 -0000 - Application type description ELECTRICAL ONLY Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . RESIDENTIAL HIGH DENSITY Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc PV system ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ EDWIN B JR AND IRENE E SHOWN POWER TRIP ENERGY CORP. 204 W 7TH ST 83 DENNY AVE PORT ANGELES WA 98362 PORT TOWNSEND WA 98368 (360) 643-3080 ---------------------------------------------------------------------------- Permit . . . . . . ELECTRICAL ALTER RESIDENTIAL Additional desc . . Permit Fee . . . . 165.00 Plan Check Fee .00 Issue Date . . . . 4/02/18 Valuation . . . . 0 Expiration Date . . 9/29/18 Qty Unit Charge Per Extension 1.00 102.0000 ECH EL -RENEWABLE 5-KVA OR LESS 102.00 1.00 63.0000 ECH EL -R- BRANCH CIR WO/ SER FEED 63.00 --------------------------------------- ------------------------------------ Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 165.00 165.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 165.00 165.00 .00 .00 U REPORT STATE SALES TAX on your excise tax 00rm to the City of Fort APO$* :::, .,_ (Location Code 0602) i` 1 I INSPECTION TYPE DATE: RESULTS: INSPECTOR: DITCH SERVICE i ROUGH -IN FINAL COMMENTS: PERMIT WILL EXPIRE SIX (6) MONTHS FROM LAST INSPECTION Signature of owner or Electrical Contractor X Date: M CITY OF PORT ANGELES PERMIT APPLICATION Building Division/Electrical Inspections 321 East Fifth Street — P.O. Box 1150 / Port Angeles Washington, 98362 Ph: (360) 417-4735 Fax: (360) 417-4711 Date: -3 /27Z2018 —1 & 2 Single Family Dwelling RECEIVE t, i * Plan Review May Be Required, Please Complete Electrical Plan Review Information Sheet Job Address: 204 WEST 7TH STREET, PORT ANGELES, WA 98362 Building Square Footage: APPROX 175() S(] FT Description of above GRID -TIED ROOF MOUNTED SOLAR ELECTRIC Owner Information Contractor Information Name: EDWIN AND IRENE SHOWN Name: power Trip Energy Mailing Address: 204 WEST 7TH STRUT Mailing Address: 83 Dennv Ave CityRORT ANGELES State: WA Zip: 98362 City: port Townsend State: WA Zip: 98362 Phone: 360-477-1925Fax: Phone:ten-643-3nsn FaX: 360-539-1857 License ## / Exp. License # / Exp. POWER964JN Exp 4-15-2018 Item Unit Charge gty Total (Qty Multialied by Unit Charoe) Service/Feeder 200 Amp. $120.00 $ Service/Feeder 201.400 Amp. $146.00 $ Service/Feeder 401-600 Amp $ 205.00 $ Service/Feeder 601-1000 Amp. $ 262.00 $ Service/Feeder over 1000 Amp. $ 373.00 $ Branch Circuit W1 Service Feeder $ 5.00 $ Branch Circuit W/O Service Feeder $ 63.00 1 $ $63 Each Additional Branch Circuit $ 5.00 $ Branch Circuits 1.4 $ 75.00 $ Temp. Service/ Feeder 200 Amp. $ 93.00 $ Temp. Service/Feeder 201400 Amp. $110.00 $ Temp. Service/Feeder 401-600 Amp. $149.00 $ Temp. Service/Feeder 601-1000 Amp . $168.00 $ Portal to Portal Hourly $ 96.00 $ Signal Circuit/ Limited Energy -1 & 2 Family Dwelling $ 64.00 $ Manufactured Home Connection $120.00 $ Renewable Electrical Energy - 5KVA System or Less $102.00 1 $ $102 Thermostat $ 56.00 $ Note: $5.00 for each additional T-Stat NEW CONSTRUCTION ONLY: First 1300 Square Ft. $120.00 $ Each Additional 500 Square Ft. or Portion of $ 40.00 $ Each Outbuilding or Detached Garage $ 74.00 $ Each Swimming Pool or Hot Tub $110.00 $ $ $165 Total Owner as defined by RCW.19.28.261: (1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is required to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection. After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I am making the electrical installation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296-46B, The City of Port Angeles Municipal Code, and Utility Specifications and PAMC 14.05.050 regarding Electrical Permit Applications. Signatilre of owner, electrical contractor or electrical administrator: '4- Dated: ❑ Cash ❑ Check ❑ Credit Card # 0110112012 A t CITY OF PORT ANGELES PERMIT APPLICATION Building Division/Electrical Inspections 321 East Fifth Street – P.O. Box 1150 / Port Angeles Washington, 98362 ; r;• ! NrALV Ph: (360) 417-4735 Fax: (360) 4174711 Date: 3/2112018 —1 & 2 Single Family Dwelling * Plan Review May Be Required, Please Complete Electrical Plan Review Information Sheet Job Address: 204 WEST 7TH ST, PORT ANGELES ,WA 98362 Building Square Footage APPROX_ 1750 SO FT Desai tion of above R�OF MOUNTED GRID -TIED SOLAR ELECTRIC Owner Information Contractor Information Name: EDWIN AND IRENE SHOWN Name: Power Trip Energy Corp Mailing Address' 9t1Q WFfiT 7TH &T Mailing Address: 83 Denny Ave Crty:POR7 A C FS N GFf S. State. WA Zip: 98362 Cit Port Townsend State: WA zip: 98362 Phone: 360477-1925 Fax Phone: 360 643-3080 Fax 360-539-1857 License # / Exp. License # I Exp- POWERTE964,TN EXP 4 . 15 2018 bm Unit Charge Qty Total ( uitintied by Unit Charge) Servic eiFeeder 200 Amp. $120.00 12.0 1 _ $ Service/Feeder 201-400 Amp. $146.00 $ Serv*Jo Feeder 401-600 Amp $ 205 DO $ Service/Feeder 601-1000 Amp. $ 262.00 _ _ $ ServicelFeeder over 1000 Amp $ 373.00 $ Branch Circuit W/ Service Feeder $ 5.00_ $ Branch Circuit W/O Service Feeder $ 63.00 ? _- $ 63 Each Additional Branch Circuit $ 5.00 Branch Circuits 1-4 $ 750 $ Temp. Service/ Feeder 200 Amp. $ 9300 $ Temp. Service/Feeder 201-400 Amp. $110.00 $ Temp. SefvicelFeeder 401-6W Amp $149.00 $ Temp. Service/Feeder 601-1000 Amp $168.00 $ Portal to Portal Hourly $ 96.00 S Signal Circuit/ limited Energy -1 & 2 Family Dwelling $ 6400 $ Manufactured Hone Connection $12000 $ Renewable Electrical Energy - 5KVA System or Less $10200 i $ 102 Thermostat $ 5600 Note: $5.00 for each additional T-Stat CONSTRUCTM ONLY: NEIN First 1300 Square Ft. $120.00 $ Each Additional 500 Square Ft. or Portion of $ 40.00 $ Each Outbuilding or Detached Garage $ 74.00 $ Each Swimming Pool or Hot Tub $110.00 . $ $ 285 Total Owner as defined by RCW.19.28.261: (1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is required to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection. After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I am making the electrical installation or alteration in compliance with the electrical laws, N.E.G., RCW. Chapter 19.28, WAC. Chapter 296-46B, The City of Port Angeles Municipal Code, and Utility Specifications and PAMC 14.05.050 regarding Electrical Permit Applications. Signature of owner, electrical contractor or electrical administrator: ❑ cash ❑ check ❑ CreditCarde x Dated: OIIOIIM12 c Application and Checklist for Roof Mounted Residential Solar Panels Project Information: Property Owner Name: Project Address: Contractor Name Contractor Phone: PV system description EDWIN AND IRENE SHOWN 204 WEST 7TH STREET POWER TRIP ENERGY CORP 360-643-3080 8.71 kW Roof Mounted Grid -Tied Solar Phone: 360-477-1925 Registration # Mfg /model # of major equip: SPR-X21-335-BLK-GAC Per WAC 51-51-2300, if the answer to the following questions is "yes" a building permit will be issued for simple (10-15kw output) PV systems without further engineering. Section M2302.2.1— Where solar panels are installed on roofs, the roof structure shall be deemed adequate to support the load of the rooftop if all of the following are met: Yes No 1. PV system is designed and proposed for a single family or detached accessory structure © ❑ 2. Will the photovoltaic panels and modules and supporting structure shall be constructed of ® ❑ noncombustible materials or fire -retardant treated wood equivalent to that required for the roof construction. The installation shall meet the requirements of the International Fire Code as amended by WA State. PV modules are listed and labeled with a fire classification in accordance with UL 1703 3. The PV system is designed for the wind speed of the local area and will be installed per the manufacturer's specifications. M ❑ 4. The ground snow load does not exceed 70 pounds per square foot. The PV system is designed 0 ❑ for the wind speed of the local area, and will be installed per the manufacturer's specifications. 5. Total dead load of modules, supports, mountings, raceways and all other appurtenances weigh ❑ no more than four pounds per square foot. Enter total dead load of system (lbs/ft'): 6. Supports for solar modules are installed to spread the dead load across as many roof -framing ® ❑ members as needed to ensure that no point load exceeds fifty (50) pounds. Modules are mounted no higher than 18" above the surface of the roofing to which they are affixed and do not exceed the highest point of the roof unless approved by the local jurisdiction. NOTE: If site inspection indicates a concern that the roof structure is not adequate to support the PV module(s), engineering may be required prior to final of the permit. As the property owner or authorized represent v the above listed property, I attest that all information in this checlllisp is accWitg to t my knowl ge. Applicant Signature:/ f� , Ll Qate:Applicant Name (Please Print):A Relationship to Property Owner: Design -Driven Advantages #1 module aesthetics and efficiency' Unmatched module reliabilityz No electrolytic capacitors 25 -year Combined Power and Product Warranty Maximize Value for Roof Size system for roof, not string inverter Optimize performance of each module Expand Deployment Options Complex roofs and partial shading Small systems System expandability Simplify & Speed Installation Factory -integrated microinverter Robust, double -locking AC connectors Design flexibility offsite and onsite No DC string sizing process Fewer installation steps than competing systems Intuitive commissioning Component of Complete System Built for use with SunPower'°' InvisiMount"^ and the SunPower Monitoring System Superior system reliability and aesthetics Optimize System and Installation Efficiency a SERIES SunPower AC Modules, which include a factory -integrated SunPower mlcroinverter, provide a revolutionary combination of high efficiency, high reliability, and module -level DC -to -AC power conversion. Designed specifically for use with SunPower InvisiMount" and the SunPower Monitoring System, SunPower AC Modules enable rapid installation, best -in -class system aesthetics, and intuitive visibility into system performance. All this comes with the best Combined Power and Product Warranty in the industry. sunpower.com SPR-X21-335-131LK{-AC SPR-X24327-BLK-C AC Nom!na' Power'(Prom) 335 W 327 W Power Tolerance *5/-0%- - +5/-0%_ Avg. Pare Efficiency' 21.0% 20.4% Temp. Coe`. (Pcwer) -0.29%/°C ' Three bypass diodes Snade To!. -ante integrated module -level maximum power point tracking Output @ 240 V (min./nom./max) 211/240/264 V Output @ 208 V (min./nom./max.) 183/208/229 V Operating Frequency (min./nom./max) 59.3/60.0/60.5 Hz Output Power Factor (min.) 0.99 AC Max. Continuous Output Current @ 240 V 1.33 A AC Max. Continuous Output Current @ 208 V 54 A AC Max. Cont. Output Power 320 W DC/AC CEC Conversion Efficiency 96.0% Max. Units Per 20 A Branch Circuit @ 240 V 12 (single phase) Max. Unix Per 20 A Branch Circuit @ 208 V 10 (two pole) No active phase balancing for 3 phase installations IMMIFIMM Soar Cels 96 Vonocrys`a, ine Vaxecn Gen ill =rort Glass L�igr-traasm,ssior tempered g ass *it') art; -ref ectve coating Env ronmectal Katrg Outcoor rated Gass 1 bias; ancd.zed (hlgnest AAIVA - �.a,me -acirg; `rVelgh: 45 5 lbs (20.6 Kg) Max. Peccr-nme-lec 3,n. (33 mm) Module Spac ng '-!Shesr of over 3,200 silic:-'r solar pareh, ,'ioton S1oJuIe S r.ey, web 21 rarI in "P': 41od,.le Durability Irnbab- Public Pcpor, Lraurhoter ;E, =eh ?013 Fire �f the top eightiargestmanufact.re,swere—tea Campe;i,,7 r.,l "Sunro,r;erVoaule �egradatiur Rats=," S,.nPov,er wh:Le paoe', neo 2013 See rmch sirpower con -if3,rs'or cr- ails, Stag,., a,nditiniC_ ,'1 i_ _j :Rt;__ib -r . ''n _ (;r, Ie Gr I.-37 -'f --_ -'.7 :. ...r .all 1_oi.,qg rr,-;lir-er ir. Operating `emc -40° a to -185' F (-_'-0° C to -85° C) Max Ambler, Temp, Max Loac A/ -d 62 ?sf, 3000 Pa, 305 Kg/hi front & hack Snow 125 psf, 6000 Pa, 611 kg/m'- =ront nch ',25 mm) d!amete, ^.all at 52 mph ,23 Mpac;-iesls.ance 25 -year hrr tec power warranty 0/a"antes - _- — 25 -year imied procuc: wa-anty _ -- i- iiS;ed-c UL 741, ncluoing: EEE'5=7'"5u7aancIEEE'547. 1%1.547.'a'Jtlllty interactive PV :?ap!c S',,:dc'vvr EgL,:pme•1t E -io-er; Gro[.rd!cg UL 6703, _ _ 97103 Ccnne=rs and cables ; cad b,ea.< c sccnnect or, i_ 1703 PV Mcdules (Type 2 fire rat!rg) Certifica0ors _�aoles nS-a;;at on r accordance wit P. NEC 6'90.6 NEC 6910 "2 Pac d S,utdotiv-, (irside and outside ,he array? NEC 690.15 All Connectors, 590.33(A) - (E)(1) FCC anc CES -I'33 Class B Whet -sed w'tl- 'fivslV1cunt rac','ng (�L 27C3) rteg-atec grci-:'dlrg and bonding Cass A. fire rated PID Tes_ Fctent a ,ndu ed degradatlo gree 280 m p [11.02 in e 1107 _Y 3 [43 o inn]] 1046 mm _ 1 2,n] r r! � 1 2 e] V 1558 mm [61 3 n] Please read the safety and installation instructions for details >ee to, mo -e •ete er.:- „rater Toe jet, i:s, see ex[ercec oatasheet , %av; swrowe,.om, aatasreets Document # 515216 Rev D /LTR_US ELECTRICAL PERMIT CITY OF PORT ANGELES 360-417-4735 Application Number . . . . . 18-00000454 Date 4/02/18 Application pin number . . . 691794 Property Address . . . . . . 204 W 7TH ST ASSESSOR PARCEL NUMBER: 06 -30 -00 -0 -2 -3300 -0000 - Application type description ELECTRICAL ONLY Subdivision Name . . . . . . Property Use Property Zoning . . . . . . . RESIDENTIAL HIGH DENSITY Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc PV system ---------------------------------------------------------------------------- Owner Contractor EDWIN B SR AND IRENE E SHOWN POWER TRIP ENERGY CORP. 204 W 7TH ST 83 DENNY AVE PORT ANGELES WA 98362 PORT TOWNSEND WA 98368 (360) 643-3080 ---------------------------------------------------- Permit . . . . . . ----------------------- ELECTRICAL ALTER RESIDENTIAL Additional desc . . Permit Fee . . . . 165.00 Plan Check Fee .00 Issue Date . . . . 4/02/18 Valuation . . . . 0 Expiration Date . . 9/29/18 Qty Unit Charge Per Extension 1.00 102.0000 BCH EL -RENEWABLE 5-KVA OR LESS 102.00 1.00 63.0000 ECH EL -R- BRANCH CIR WO/ SER FEED 63.00 ---------------------------------------------------------------------------- Fee summary Charged ----------------- ---------- Paid Credited Due ---------- Permit Fee Total 165.00 ---------- ---------- 165.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 165.00 165.00 .00 .00 INSPECTION TYPE DATE: DITCH SERVICE ROUGH -IN FINAL COMMENTS: PERMIT WILL EXPIRE SIX (6) MONTHS FROM LAST INSPECTION RESULTS: d REPORT STATE SALES TAX on your excise tax form to the City of Port Angeles (Location Code 0502) 7 INSPECTOR - VR Signature of owner or Electrical Contractor X Date: