Loading...
HomeMy WebLinkAbout430 WHIDBY AVE - Building (2)ELECTRICAL PERMIT CITY OF PORT ANGELES 360-417-4735 Application Number . . . . . 18-00000268 Date 3/01/18 Application pin number . . . 567752 Property Address . . . . . . 430 WHIDBY AVE ASSESSOR PARCEL NUMBER: 06 -30 -10 -5 -0 -0706 -0000 - Application type description ELECTRICAL ONLY Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . RS7 RESDNTL SINGLE FAMILY Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc PV system ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ VIA V & RAYMOND F WEIGEL TTES POWER TRIP ENERGY CORP. 430 E WHIDBY AVE 83 DENNY AVE PORT ANGELES WA 98362 PORT TOWNSEND WA 98368 (360) 643-3080 ---------------------------------------------------------------------------- Permit . . . . . . ELECTRICAL ALTER RESIDENTIAL Additional desc . . Permit Fee . . . . 285.00 Plan Check Fee .00 Issue Date 3/01/18 Valuation . . . . 0 Expiration Date 8/28/18 Qty Unit Charge Per Extension 1.00 102.0000 ECH EL -RENEWABLE 5-KVA LESS 102.00 1.00 120.0000 ECH EL -0-200 SAV FEiiW 120.00 1.00 63.0000 ECH EL -R- BRANCH CIR W©/ SER FEED 63.00 ' Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 285.00 285.04) .00 .00 Plan Check Total .00 00 OQ .00 Grand Total 285.00 285.00 .00 .00 { INSPECTION TYPE DITCH SERVICE ROUGH -IN FINAL COMMENTS: DATE: RESULTS: r PERMrr WILL EXPIRE six (6) MONTHS FROM LAST iNspECTIoN Signature of owner or Electrical Contractor X REPORT STATE SALES TAX on your exdse tax form to the City of Port Angeles (Locadon Code =2) I INSPECTOR: Date: CITY OF PORT ANGELES PERMIT APPLICATION Building Division/Electrical Inspections 321 East Fifth Street — P.O. Box 1150 / Port Angeles Washington, 95362 Ph: (360) 4174735 Fax: (360) 4174711 — 18 2 Single Family Dwelling Tat Plan Review May Be Required, Please Complete Electrical Plan Review Information Sheet ,tab Address: 430 WHIDBY AVE, PORT ANGELES, WA 98362 Building Square Footage: APPROX 1440 SQFT Description of above 11.72 kW GRID -TIED ROOF MOUNTED SOLAR ELECTRIC Owner Information Contractor Information Nom: VIA AND RAYMON WEIGEL Nine: Power Trip Energy Corp Mailing Address. .IDBY AVE Majing Address. 83 Denny Ave City. PORT ANGELESState: WA_ Zip: 98362 - - City Port Townsend State. - !?A _Zip: _ 98362 - PhoneS 57-0643 Fax: Phone: 360 643-3080 Fax: 360 539 1857 License # / Exp. License # / Exp. PowERTE964LN EXP 4-15-2018 bm Unit Cha= 94 Total ft�iWied by unit Charge) Service/Feeder 200 Amp. $120.00 ? _ $ Service/Feeder 201400 Amp. $146.00 $ Service(Feeder 401-600 Amp $ 205.00 __. $ Service/Feeder 601-1000 Amp. $ 262.00 $ Service/Feeder over 1000 Amp. $ 373.00 $_. _.._ Branton Circuit W1 Service Feeder $ 5.00 _ $ Brand Circuit WIO Service Feeder $ 63.00 i $ 63 Each Additional Branch Circuit $ 5.00 $ Branch Circuits 14 $ 75.00 $ Temp. Servicet Feeder 200 Amp. $ 93.00 _---_- _- $ Temp. Service/Feeder 201-400 Amp. $110.00 _. _ _ $ Temp. ServkWFeeder401.600 Amp- $149.00 Temp. ServicetFeedw 601-1000 Amp . $168.00 Portal to Portal hourly $ 96.00 Signal Circuit/ Limited Energy -1 & 2 Family Dwelling $ 64.00 Manufactured Home Connection $120.00 __ $ Renewable Electrical Energy - 5KVA System or less $102.00 z $ z o z Thermostat $ 56.00 $ Note: $5.00 for each additional T-Stat First 1300 Square Ft. $120.00 Each Additional 500 Square Ft- or Portion of $ 40.00 $ Each Outbuilding or Detached Garage $ 74.00 $ Each Swimming Pool or Hot Tub $110.00 $ __ . __ _ $ 295 Total Owner as defined by RCW.19.28.261.- (1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is required to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection. After reading the above statement, I hereby oertify that I am the owner of the above named property or a licensed electrical contractor. I am making the electrical installation or alter4Wq in compliance with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296-46B, The City of Port Angeles Municipal Code, a til' Specifications and PAMC 14.05.050 regarding Electrical Permit Applications. Signature of ohm tectrical Conka*r or electrical administrator: ❑ Caao ❑ Cts r ❑ Cmdk Card a - , Dated: � r of .� _ - 01101r2012 V Solar Agent: Michael Slater Client Name: Weigel Residence Power Trip Energy Corp 83 Denny Ave Port Townsend, WA 98368 (360)643-3080 www. powertripenergy.com LIC: POWERTE964JN Project: Weigel Residence- Client: Via Weigel Phone: (360) 457-0643 Address: 430 Whidby Ave, Port Angeles, WA 98362 System Description: 11.73 Residential Grid -tied PV Solar Modules: Branch Circuit A-12 Sunpower 335W AC modules Model: SPR-X21-335-BLK-AC Micro inverter max power output 320 watts West house roof Solar Modules: Branch Circuit B-12 Sunpower 335W AC modules Model: SPR-X21-335-BLK-AC Micro inverter max power output 320 watts West house roof Solar Modules:Branch Circuit C- 11 Sunpower 335W AC modules Model: SPR-X21-335-BLK-AC Micro inverter max power output 320 watts West house roof Utility Grid: City of PA PUD Net Meter: West exterior wall of house, toward North Meter #:14318 Main Service Panel (LOAD): 200 Amps Interior West wall of basement AC Circuit Combiner Panel: West exterior wall of house, toward South AC System Disconnect: (Visibly Open and Lockable) West exterior wall of house, toward South Production Meter: West exterior wall of house, toward South Line I Line 2 ♦ Load 1 I� 2 February 20, 2018 - 3 - Design -Driven Advantages #1 module aesthetics and efficiency' Unmatched module reliabilityz No electrolytic capacitors 25 -year Combined Power and Product Warranty Maximize Value for Roof Size system for roof, not string inverter Optimize performance of each module Expand Deployment Options Complex roofs and partial shading Small systems System expandability Simplify & Speed Installation Factory -integrated microinverter Robust, double -locking AC connectors Design flexibility offsite and onsite No DC string sizing process Fewer installation steps than competing systems Intuitive commissioning Component of Complete System Built for use with SunPowerO InvisiMount1m and the SunPower Monitoring System Superior system reliability and aesthetics Optimize System and Installation Efficiency SERIES SunPower AC Modules, which include a factory -integrated SunPower microinverter, provide a revolutionary combination of high efficiency, high reliability, and module -level DC -to -AC power conversion. Designed specifically for use with SunPower InvisiMountlm and the SunPower Monitoring System, SunPower AC Modules enable rapid installation, best -in -class system aesthetics, and intuitive visibility into system performance. All this comes with the best Combined Power and Product Warranty in the industry. sunpower.com Wet- Date SPR-X21-33rBLK-GAC SPR4120-327-81-K-CAC Nominal Power�(Pnom) 335 W 327 W Power Tolerance +5/-0% +5/-0% Avg. Panel Efficiency' 21.0% 20.4% Temp Coef. (Power) -0.29%/°C Three bypass diodes Shade Tolerance • Integrated module -level maximum power point tracking AC Electrical Data Data Output @ 240 V (min./nom./max.) 211/240/264 V Output @ 208 V (min./nom./max.) 183/208/229 V Operating Frequency (min./nom./max.) 59.3/60.0/60.5 Hz Output Power Factor (min.) 0.99 AC Max. Continuous Output Current @ 240 V 1.33 A AC Max. Continuous Output Current @ 208 V — --- -- --- - -.... 1.54 A AC Max. Cont Output Power - -1 320W DC/AC CEC Conversion Efficiency 96.0% Max. Units Per 20 A Branch Circuit @ 240 V 12 (single phase) Max. Units Per 20 A Branch Circuit @ 208 V 10 (two pole) i No active phase balancing for 3 phase 1107 mm [43.6 in] installations JjffjM12dhah4, Data `Solar Cells - 96 Mon q(agalline Maxeon Gen 11 -- -- Front Glass High -transmission tempered glass with Class A fire rated anti -reflective coating Environmental Rating Outdoor rated Frame Class 1 black anodized (highest AAMA rating) Weight 45 5 lbs (20.6 kg) Max. Recommended 1 3 in. (33 mm) Module Spacing 'Highest of over 3,200 siiicnn solar panels, Phnron Module Su,vey, Feb. '014 '#I rank in TV Module Durability Initiative Public Report" Fraunhofer CSE, reb 2013 Hve nut of the top eight largest manutacturers were tested Cat, oeau, Z etal "Son Power Module Degradation Rate," Sun Power white paper Fee 2013. Sen www sunpower cnmrfarts fix JFtalfs Standard Tea i onditiorr !1 ,ti 0 W, m= in adian, e, AM 1 5, 25' Q NR alibrannn st=nu=i d or rent, I At--S� �F and voitaee Ali US volr.i F is f, �ll;� contained within the mn�,lcde 'Basad or a�P oFe of IT, ,a u,ed power ,,alue_. du, Ing production i, 'M yI ip+i!i!...............,il ! liu,i nldil OuV® !?! IJi dh II II Operating Temp -40° F to --185° F (-40° C to -85° C) Max, Ambient 22° F (50° C) Temp, Max Load Wind 62 psf, 3000 Pa, 305 kg/m2 front & back j Snow -125 psf, 6000 Pa, 611 kg/m2 front 1 inch (25 mm) diameter hail at 52 mph (23 Impact Resistance m/S) Warranties 25 -year limited power warranty 25 year limited product warranty_ - UL listed to UL 1741, Including IEEE1547/1547a and IEEE1547.1/15471a Utility Interactive PV Rapid Shutdown Equipment Equipment Grounding UL 6703, UL 9703 Connectors and cables (load break disconnection) UL 1703 PV Modules (Type 2 fire rating) Certifications Enables installation in accordance with: NEC 690.6 NEC 690.12 Rapid Shutdown (inside and outside I he array) NEC 690.15 AC Connectors, 690.33(A) - (E)(1) FCC and ICES -003 Class B Please read the safety and installation instructions for details, See www sunpower com/facts to, more refe•ence information. For more details, see extendeo datasheet www sunpower corn/datashee.ts Document 4 515216 Rev D /LTR -US When used with InvlsiMount racking (UL 2703) Integrated grounding and bonding Class A fire rated I PID Test Potential -induced degradation free -- 28 mm14 [11.02 rn] e 1107 mm [43.6 in] 1046 mm - -_ - _ [41 2 in] -___- 1558 mm 161,3 in) Please read the safety and installation instructions for details, See www sunpower com/facts to, more refe•ence information. For more details, see extendeo datasheet www sunpower corn/datashee.ts Document 4 515216 Rev D /LTR -US West Exterior Wall: Existing Utility Meter West Interior Wall: Service Panel Vent on roof — NO MODULES West Exterior Wall: -Production Meter W Combiner Panel - AC Disconnect mer Trip Energy Corn Property Lines (35) SunPower Modules on West Roof SunPower X21 -335 -C -AC Using integrated Micro -Inverters Vent on roof — NO MODULES N ELECTRICAL PERMIT CITY OF PORT ANGELES 360-417-4735 Application Number . . . . 18-00400268 Date 3/01/18 Application pin number 567782 Property Address . . . . . . 430 WHIDBY AVE ASSESSOR PARCEL NUMBER! 06 -30 -10 -5 -0 -0706 -0000 - Application type description. ELECTRICAL ONLY 'Subdivision Name . . . . . Property Use . . . . . , . . Property Zoning RS7 RESDNTL SINGLE FAMILY Application valuation . 0 _ -- - ---- -- ------------------ ---------- Application desc PV system Owner Contractor VIA V & RAYMOND F WEIGEL TTES POWER TRIP ENERGY CORP. 430 E WHIDBY AVE 8.3 DENNY AVE PORT AIWEI+ES WA 98362 PORE' TOWNSEND WA 98368 (3600 643-3080 4 Permit . . . ELECTRICAL ALTER RESIDENTIAL Additional desc . Permit Fee. 288.00 Plan Check Fee .00 Issue Date 3/01/ -Ie Valuation . . . . 0 Expiration Date . 8/28/18 Qty Unit. Charge_Per Extension 1.4.0 102.00OQ. BON BL-RENSWABLE 5=KVA.OR LESS 102.00' 1.00 120.Q.OH BCH. EIS -0-200 SRV FEEDER 120.100 1.00 63.0000 BCH EL -R-, BRANCH CIA Wry/ SER FEED 63.00 Fee summary~ Charged' --------------- Paid Credited Due Permit Fes Total 2.86:00 y 285.00 .00 .00 Plan Check Total .00 .00 00 .00 Grand total 285,00 285.00 .00 .00 f REPORT STATE SALES TAX on your excise tax form to the City of Port Angeles (Location Code 0502) If INSPECTION TYPE ,DATE: RESULTS: INSPECTOR: .. _.. . _._...:_ .. DITCH SERVICE ..,.- . ROUGH -IN .. ,� . .. FINAL I. COMMENTS: PERMIT WILL EXPffW SIX (6) MONTHS .FROM LAST INSPECTION Signature of owner or _Electrical Contractor X Date: