HomeMy WebLinkAbout130 E RAILROAD AVE - BuildingELECTRICAL PERMIT CITY OF PORT ANGELES 360-417-4735 Application Number . . . . . 17-00001647 Date 2/07/18 Application pin number . . . 906835 Property Address . . . . . . 130 E RAILROAD AVE ASSESSOR PARCEL NUMBER: 06 -30 -00 -5 -0 -0043 -0000 - Application type description ELECTRICAL ONLY Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . CENTRAL BUSINESS DISTRICT Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc Car charging service and location ---------------------------------------------------------------------------- Owner Contractor ------------------------ CLALLAM TRANSIT SYSTEM ------------------------ SEAHURST ELECTRIC INC 830 LAURIDSEN BLVD 2915 CHESTNUT ST PORT ANGELES WA 98363 EVERETT WA 98201 (425) 258-1882 ---------------------------------------------------------------------------- Permit . . . . . . ELECTRICAL NEW COMMERICAL Additional desc . . Permit Fee , . . . 235.00 Plan Check Fee .00 Issue Date . . . . 11/08/17 Valuation . . . . 0 Expiration Date . . 8/06/18 Qty Unit Charge Per Extension 2.00 5.00-00 ECH EL -BRANCH CIRCUIT W/FEEDER 10.00 1.00 225.0000 ECH EL -COM 401-600 SRV FEEDER 225.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due Permit Fee Total 235.00 235.00 .00 .00 ,Plan Check Total .00 .00 .00 .00 Grand Total 235.00 235.00 .00 .00 INSPECTION TYPE 1 DITCH SERVICE ROUGH -IN FINAL COMMENTS: '-E7-15' 41 Z. � . DATE: RESULTS: PERMIT WILL EXPIRE SIX (6) MONTHS FROM LAST INSPVCTION 11).— � {—*Ak Signature of owner or Electrical Contractor X It REPORT STATE SALES TAX on your excise tax form to the City of Port Angeles (Location Code 0502) 1 Date: vA 00,014r,%ELECTRICAL INSPECTION WIRING REPORT RKS 6 417-4735 � DATE. PERMIT # I INSPECT94 zl -7 1 t $ n OWNER CONTRACTOR S*LA K UTZ4�� -� L���L1� s e -- ADDRESS i � tf2 12,».L i_. f2Z 4�, D APPROVED NOT APPROVED ❑ ....................DITCH.................... ❑ ❑................ ROUGH IN/COVER ............... ❑ ❑ ....................SERVICE................... ❑ ❑ .....................FINAL.................. yCORRECTIONS NEEDED: S*Tiv [cic— ��Ut4 r-.�►� ,�` >57 NOTIFY INSPECTOR WHEN CORRECTIONS ARE COMPLETED WITHIN 15 DAYS -- DO NOT REMOVE -- 425-259-2794 CITY OF PORT ANGELES PERMIT APPLICATION Building Division/Electrical Inspections 321 East Fifth Street — P.O. Box 1150 I Port Angeles Washington, 98362 Ph: (360) 4174735 Fag: (360) 4174711 Date: OCTOBER 26,2017 Commercial Multi -Family or Commercial* 01:23:40 p.m. 10-26-2017 N 2/15 * Plan Review May tae Required, Please Complete Electrical Plan Revi Information Sh et Job Address: -96362 Building Square Footage: Description of above PORT ANr;FI FR TRANA1T rFNTFR OwnerggTt �ELES GATEWAY TRANSIT CENTER Contractor Information Name: Name. Seahurst Electric Mailing Address: 19.,4 F FROAIT ST Maiiing Address: 2915 Chestnut St City. PORT ANGELE%tate: WA Zip: 98362 City. Everett State: wA_Zip: 98201 Phone- 3W-451-4511 Fax: Phone: 425-2584682 Fax: 42 259-2744 Ucense # l Exp. License # l Exp. 6EAHUEI99QN Item Unit Charoe Qtv Total (Qtv Multiolied by Unit Charnel Service/Feeder 200 Amp. $132.00 $ Service/Feeder 201400 Amp. $160.00 $ ServiceJFeeder 401.600 Amp $ 225.00 1 $ 225.00 , Service/Feeder 601-1000 Amp. $ 288.00 $ Service/Feeder over 1000 Amp. $ 410.00 $ Branch Circuit W1 Service Feeder $ 5.00 2 $ 10.00 Branch Circuit W/O Service Feeder $ 74.00 $ Each Addition al Branch Circuit $ 5.00 $ Branch Circuits 1-4 $ 86.00 $ Temp. Service/ Feeder 200 Amp. $102.00 $ Temp. Service/Feeder 201.400 Amp. $121.00 $ Temp. Senrice/Feeder 401.600 Amp. $164.00 $ Temp. Service/Feeder 601-1000 Amp . $185.00 $ Portal to Portal Hourly $ 96.00 $ Sign/Outline Lighting $ 88.00 $ Signal Circuit/ limited Energy - Mut&Famdy $ 64.00 $ Signal Circuill Limited Energy /First 1500 sf - Commercial $ 96.00 1 $ Note: $5.00 for each additional 1500 sf Renewable Electrical Energy - 5KVA System or less $113.00 $ Thermostat $ 56.00 $ Note: $5.00 for each additional T-Stat $ 235.00rotal Owner as defined by RCW.19.28.261: (1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is required to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection. After reading the above statement, (hereby certify that I am the owner of the above named property or a licensed electrical contractor. I am making the electrical installation or alteration in compliance with the electrical laws, N.EC., RCW. Chapter 19.28, WAG. Chapter 296468, The City of Port Angeles Municipal Cade, and Utility Specifications and PAMC 14.05.050 regarding Electrical Permit Applications. Signature of owner, electrical contractor or electrical administrator: ❑ cash ❑ Check N A�17 Credit Card a ALt�ru fl, t4Yi % t.17 x Dated: O 41 rY f 0110IM12 %t41rAt/� l�� 425-259-2794 01:24:14 p.m. 10-26-2017. 3115 Electrical Information Form T— Public Works 8r Utilities Department (360) 417-47011 `-ter►. City Electrical Inspector (360) 417-4735 Please complete and return to Public Works & Utilities Department Project Address: Owner., Street Address City/State l Zip: Phone Number. Company Name: Contact Name: Phone Number. PORT OF ANGELES GATEWAY TRANSIT CENTER 123 E. FRONT ST PORT ANGELES, WA 98362 360-452-4511 SEAHURST ELECTRIC JEFF HERRMANN 425-258-1882 i�roject Type ® Existing ❑ Single-family residence ❑ Commercial ❑ Overhead service ® Underground service '�'Iroject Information Call Phone: Cell Phone: 425-309-2554 ❑New ❑ Multi -family residence; # of units ❑ Subdivision ❑ General service ❑ Other: Detailed description of INSTALL NEW 400 AMP 1201208 3 PH SERVICE TO POWER ONE (1) 50KW ELECTRIC CAR work: (Oil to Gas CHARGER AND ONE (1) 7.2 KW ELECTRIC CAR CHARGER AT TEH PORT ANGELES GATEWAY Conversion, Gas to TRANSIT CENTER. Electric, New Heat Pump, etc.) Disconnect Size Select Voltage: ❑l 201240 1 ph ©120/208 3ph ❑277/480 3ph Amps: 400A ❑120/240 3ph ❑480 3W 3ph Check all that apply: LJ Standard residential loads (Lighting, refrigerator, dishwasher, washer) ❑ AIC ( _ ton) ❑ Range/Oven ❑ Hot Tub ❑ Clothes Dryer ❑ Heating ❑ Pumps C_Hp) ❑ Water Heater ❑ Elevator (_Hp) X Other 2 ELECTRIC CAR CHARGERS Load Increase (kW1 159.7544 KVA Load Decrease (kW) upporting Please provide a copy of the following: *Detailed plot plan (.dwg or .dxf format mandatory for subdivisions). *Electrical one -line drawing showing the service entrance panel and location. *Connected load data. *Size and locked rotor amps of all motors over 50hp. Applicant's Signature: Date: MAIL OR DELIVER COMPLETED FORM TO: 321 E 5TH STREET; PORT ANGELES, WA 98362 FAX TO: 360-417-4711 WS WF NewrinfouraWrkl3mrm per Trent Revised 1-09-11 425-259-2794 1 01:23:23 p.m. 10-26-2017 1/15 EA�LECTRIC FAX TRANSMITAL Date: 10-26-17 To: City of Port Angeles — Permit Services Fax# 360-417-4711 Ph# 360-417-4735 Number of pages including this sheet: 2 From: Kim Smith Fax # 425-259-2794 PH# 425-258-1882 receation0seahurst.com Please see electrical permit application and please let me know if possible to pay with visa card Thank you, Kim Smith 2915 Chestnut Street . Everett, Washington 98201 • Phone 425-258-1882 • Fax 425-259-2794 Website www.seahurst.com • Email: reception@seahurst.com PORT ANGELES SCOPE: INSTALL ONE AC LEVEL 2 AND ONE DC CHARGER CHARGERS FOR; PUBLIC USE SHEET INDEX; 1. TITLE SHEET WITH SCOPE AND AREA MAP N 2. SITE CONDITIONS & SITE DESIGN SKETCH 3. SINGLE LINE AND PANEL SCHEDULE 4. SITE MAP 5.SEMA SPECS 6. SEMA DETAILS 7. BCTP SOKW DC SPECS B. BCTP SOKW DC DETAILS 9. CIVIL DETAILS -1 10. CIVIL DETAILS -2 11. PARKING DETAILS 12, STANDARDS EVG-250.1 General Where provided, electrical vehicle charging stations shall comply with EVG-25b. ADVISORY: EVG-250.1 General Existing conditions, terrain, electric infrastructure and other factors dictate that not every electric vehicle charging station; can be fully accessible. With electric vehicle charging station being functionally;similar to and usually intergraded with parking, the ratios of accessible to standard electric vehicle charging stations in these guidelines are the same as those for accessible to standard parking in the 2010 ADA standards and the 2013 California Building Code. Pj The numbers of required accessible electric vehicle charging stations for both on- site and public rights-of-way locations are shown In Tables EVG-250.2 Ojt-site Ul Electric Vehicle Charging Stations and EVG-250.3 On -street Electric Vehicles Charging Stations NO. REVam 1 INITIAL RELEASE DAIS VM7 REV' D levo NW D u►o ABM. PORT ANGELES INTERNATIONAL 9 GATEWAY TRANSPORTATION CENTER MY >o/>2n7 N 2 UPDATED TO NEW SCOPE I Name p,ywy,iTHOMAS BER10N ra I m OLYMPIC NATIONAL PARK d to Iota sou NTS � Ch N Building Value e�i�.ybe P� 3 DRAWING CLARIFICATIONS 9/6/17 �a ra ww. THOMAS RERTON gionr s is a ABM ELECTRICAL POWER SERVICES 123 FRONT STREET r for thosPe 4 LOCATION OF CHARGERS CHANGED w1�un ro m �� wu K�5 152 TECHNOLOGY DRIVE PORT ANGELESE, WA 98362 � sesta -- -- ( IRVINE, CA 92618 OF CAGTF ,„,�, u A Zn' . r f' L8a taa �2a m , ,_._i 1 =77-F ._......� ALL WORK IS CONTAINED TO ISLAND OUTSIDE OF THE GARAGE. EXISITING SITE 150KVA TRANSFORMER WILL BE TAPPED TO FEED NEW 40DA 120/208V PANEL WITH MERTER ON ISLAND. FROM SERVICE LOCATION TO THE NEW EV CHARGEING LOCATIONS EXCEPT FOR THE SIDEWALK NEAR THE CHARGERS WILL BE SAW CUT AND TRENCEHED AND REPLACED. No. IItVWONs UAW AW MP' D P 1 INITIAL RELEASE 3rl0/17 avo Arra ABM. THOMAS BERTON 2 UPDATED TO NEW SCOPE erns/n To ro Building Value 3 DRAWING CLARIFICATIONS 9/c/17 ro ro „ , _ THOMAS BERMN ABM ELECTRICAL POWER SERVICES 4 LOCATION OF CHARGERS CHANGED wwn m ro VAN WiLKiNS 152 TECHNOLOGY DRIVE IRVINE, CA 92618 PORT ANGELES INTERNATIONAL GATEWAY TRANSPORTATION CENTER OLYMPIC NATIONAL PARK 123 FRONT STREET PORT ANGELESE, WA 99362 PROJECT BOUNDARIES 0 SNlu 7 moo Iz T vi UTILITY PRIMARY FEED PAD MOUNTED UTLIUTY TRANSFORMER )o C Panel A i o p BTCP SOM SEMA DC FAST CONNECT CHARGER LEVEL II NOTES: 40AMP 2POLE 24DVOLT CIRCUIT BREAKER IN NEW PANEL Q2 40AMP 4POLE 240VOLT DISCONNECT NEMA 3R, IF REQUIRED BY CODE (a (3) #8 THHN COPPER CONDUCTORS 176" PVC FEEDER (D 400 AMP 3 POLE 120/208 VOLT CIRCUIT BREAKER Q NEW 400A MAIN PANEL NEMA 3R O (2) SETS OF (4) #3/0 AN D (1) #2 THHW COPPER CONDUCTORS IN 2 %" AVC CONDUIT Q 200AMP 30 208VOLT CIRCUIT BREAKER IN NEW PANEL 0 (4) 113/0, (1) #4 THHW Cu CONDUCTORS In 2 %' PVC UG FEEDER Q SOkW DC Fast with integral Disconnect Three Phase Service Load Calculation IService Site Port Angeles City Light and Power 400 Amps (Voltage Email 208 I Volts lLDadCapacity 8:30 AM to 4:30 PM 137 KVA (Existing Demand Operations Manager 300I1Amps 2 Voltage 360-417-4726 I 208 Volts ILoad Demand DRAWING CLARIFICATIONS 102.5544 KVA jAdded Load 4 I CITY w+r+l' 'ra 7W VAN WILKiNs 7.2 KW charierif 1 7.2 KVA BTC POWER50KW DC FAST CHARGER 1 50 KVA Added 30 Load 159�Amps Voltage 208 Volts 30 (dad Demand 57.2 KVA New Total Load 444 AMPS Voltage 208 Volts Load Demand L4>" a/�, !j' ),,9.7544 KVA Standard Service Sire • 100,100, 400, 500,1200 Amps for 3 0 ptme Port Angeles Utility Billing Port Angeles City Light and Power Electrical Permits & Inspections Port Angeles City Hall 1707 South A Street Email 321 E %th Street, Port Angeles, WA 98362 Port Angeles WA 98362-2260 Ph: 360-417-4735 8:30 AM to 4:30 PM Michael Cyr (360) 457-0411 Operations Manager Emergency After Hours 2 Ph: 360-017-4731 360-417-4726 150KVA Transformer 120/208 Y CP0750012218 00007P08K4EA No. REVISIONS DATE REW API D D Hours _9 1 INITIAL RELEASE VM117 W" ""0 A N suu No � owarrr THOMAS BERION lw 2 UPDATED TO NEW SCOPE "Al to To Building Value 3 DRAWING CLARIFICATIONS 9/6/17 rn m pusw THOMASSERTON ABM ELECTRICAL POWER SERVICES 4 LOCATION OF CHARGERS CHANGED w+r+l' 'ra 7W VAN WILKiNs 152 TECHNOLOGY DRIVE i aru® IRVINE, CA 92618 PORT ANGELES INTERNATIONAL GATEWAY TRANSPORTATION CENTER OLYMPIC NATIONAL PARK 123 FRONT STREET PORT ANGELESE, WA 98362 A N N N I N W A 2007 5'0' Street o Suite A Port Angeles, WA 98363 W W Hours _9 Monday- Friday 3 7:00 a.m. - 3:30 p.m. D0 as: 10/12/17 p I ri to Inr:f N suu No � N ,us NTS O V MNI 3 Lug 12 o, crt '4o +s r' r H DC FAST CHARGER Q LEVEL It CHARGER U PROTECTIVE BOLLARD r®' EV PARKING SIGN LYY PROJECT BOUNDARIES --- CONDUIT RUN U® DC f l2 I MY NOTES: 1. PROJECT BOUNDARIES ARE CONFINED TO THE PARKING AREAS AROUND THE CHARGER INSTALLATION, AND THE tyyy ctrl E1?1 cccl ELECTRICAL POW ERTRANSFORMER. 2. THE STAGING AREA W ILL BE THE FOUR EXISTING PARKING SPACES AS SHOWN NEAR THE CHARGER INSTALLATION, 3. INSTALL ONE LEVEL 2 SEMA CONNECT CHARGER PEDESTAL MOUNTED 4. INSTALL ONE SOKW BTC DC FAST CHARGER PAD MOUNTED UNIT 1e' S. STRIPE AND STENCIL PER DRAWING SITE MAP 6. INSTALL ELECTRIC CHARGING SIGNS 7. SEE DETAIL A5 FOR THE FOUNDATIONS AND LIMITS OF EXCAVATION B. THE PARKING SIGNS WILL BE POLE MOUNTED SEE DETAIL.R3 9. SEE DETAIL A2 FOR PANEL MOUNTING DETAILS. N0. PtV610NS bAlt NY 0 D D PORT ANGELES INTERNATIONAL 1 INITIAL RELEASE 3/m/i7 W" A� GATEWAYTRANSPORTATION CENTER 2 UPDATED TO NEW SCOPE 4n9/17 = =�,.a THOMAS I3ERTON ABM. OLYMPIC NATIONAL PARK Building Value 3 DRAWING CLARIFICATIONS 9/6/17 - m w THOMASRERTON ABM ELECTRICAL POWER SERVICES1p 123 FRONTSTREET 4 LOCATION OF CHARGERS CHANGED [w[fm m TO ( nim V0.N W1L[tN5 152 TECHNOLOGY DRIVE FORT ANGELESE, WA 98362 r _ IRVINE, CA 92618 A N I Lo I PiN A 0 w 0 0 A 3 wa 16/12/17 O I N su¢ NTS � N ua NTS O V sn[tr 4 $MITa 12 V U7 8 I AC Power Input Level l k 30A; Line 1. Line 2 and Earth (no neutral) to Charger Connection SAE J1772 EV Connector,18ft Cable EVehicle Enerov Metering Accuracy 1% at 5 min interval (standard), 0.5% optional Standby Power SW typical Service Panel Breaker Dust ole 40A breaker, dedicated circuit Safety, Ground Fault Circuit Interrupt 5mA CCID with auto retry (15 min delay, 3 tries) Automatic Plug -Out Detection Power terminated per SAE J1772 specification: 2 SMS or email notification General Safety Compliance UL Certified; CCID per LIL 2231-1, -2; Meets Wide Area Network Commercial CDMA or GPRS cellular network I Network Communication Protocol TCP/IP Network Security HTTPS; 128 -bit AES Encryption j Maximum Charging Stations per LAN 128 Smart Card Reader ISO 15693 compliant , LED Array 210deg visibility, multi -color visual status LCD Screen 2 line, 16 characters per line Environmental Specs Outdoor Rated NEMA 3 per NEMA250-1997. IP44 per II Operating Humidity Up to 950,o non-coudensinlr Surge Protection. 6LX03.000A EMI Compliance FCC Part 15 Class A Approxiuiate Sltippiug Weights Head unit and cable: 28 lbs Bollard pedestal: 22 lbs, Wall monnt bracket•. 31bs Dimensions 20in high x 6in v6de s 6in deep N0. 1 REV6xNR INITIAL RELEASE 11A1>: 3/20/7 RW 0 Kn AW o u'u ABM. PORT ANGELES INTERNATIONAL GATE WAYTRANSPORTATION CENTER THOMAS BERTON . OLYMPIC NATIONAL PARK 2 UPDATED TO NEW SCOPE IM/17 ro ro BulldingValue 3 DRAWING CLARIFICATIONS 0/6/17 M m gmvu THOMAS BERTON ABM ELECTRICAL POWER SERVICES 123 FRONTSTREET 4 LOCATION OF CHARGERS CHANGED WW17 ro ro VAN u�ItKINS 152 TECHNOLOGY DRIVE PORT ANGELESE, WA 98362 w _ IRVINE, CA 92618 A N In I N iV1 I N V A 0 W 0 W rn 3 PAN 10/12/17 Q N UW Nn i N lap rrls v w9a 5 __n MAXIMUM AREA DISTURBED 36' DEPTH . 43' WIDE . 3V LONG SINGLE PORT BOLLARD MOUNTING DETAIL (TYPICAL) N.T.S. ND. ,,...-PROTECTION BOLLARD IMBEDDED OR 1 DOLT DOWN STYLE DEPENDING ON 2 LOCATION 3 ._..•EXIST WG GRADE 4 UANTiTY ml, OIAMRER ANCHOR BOLTS . .-^""�✓�..,-- •„,..-" WITH FLAT WASHERS AND HEX NUTS •. -"""`w `` ,,,w...-4' CONCRETE SURFACE. OR ASPHALT LAYER '^ + \ ,`� �`��\ ...-. -CONCRETE BASE 24X24'X24• — ^""'"� " •, 1!:. .. �. ��!'��'�.! __„y„.__GROUND DEPTH MAY VARY BASED UPON CLIMATE LOOP MAXIMUM AREA DISTURBED 36' DEPTH . 43' WIDE . 3V LONG SINGLE PORT BOLLARD MOUNTING DETAIL (TYPICAL) N.T.S. ND. RENIMONS 1 INITIAL RELEASE 2 UPDATED TO NEW SCOPE 3 DRAWING CLARIFICATIONS 4 LOCATION OF CHARGERS CHANGED DATE I RW AQP' D P 3/7D/17 uvo Arra „,,„#THOMAS BERTON US/17 To m 9/6/17 To m O.A” THOMAS BERTON $g urs tm m VAN WI I KINS_ WSFORMER 44'x35' z S' ILVANIZED METER MAXIMUM AREA DISTURBED 38' DEPT)i+S' WOE z X L ONG DUAL PANELBOARD AND TRANSFORMER MOUNTING DETAIL N.T.S. PORT ANGELES INTERNATIONAL ERAQMGATEWAY NT . OLYMPIC NATIONAL PARK BuildingValue 3 ABM ELECTRICAL POWER SERVICES 123 FRONTSTREET 152 TECHNOLOGY DRIVE PORT ANGELESE, WA 98362 IRVINE, CA 92618 N O 0 w N N 3 0Al2 10/12/17 I 1"19 NTs N1 0 I imp ws N O V sxsu G fMet. 12 50 kW DC Fast Charger • Dual Port CHAdeMO & SAE 71772 Combo • 15" outdoor color display with touch screen • Payment System (supports all major credit cards) • Loyalty System (customer engagement program) • Microphone • Speakers • Camera • Cord Retractor on top — (Lanyard retractor) Technical Specification Power Rating 50kW Connectors CHAdeMO, SAE 71772 Combo Network EVP, Credit Cards, Loyalty Input Power 208VAC, 3 -Phase or 480VAC, 3 -Phase Input Breaker 208 VAC 200 Amp or 480 VAC 100 Amp Frequency 50Hz/60Hz Efficiency Rating > 90% Maximum DC Output Current 125 A Max Output OC Voltage 50-500V Operating Temperature -35 C to 50 C PORT ANGELES INTERNATIONAL GATEWAY TRANSPORTATION CENTER OLYMPIC NATIONAL PARK 123 FRONT STREET PORT ANGELESE, WA 98362 N N I N W A W 00 Dimensions 38" [w) x 72.75"[h] x 27.6"[dj Safety Compliance UL2202, UL2231-1, UL 2594, UL 2202 XQ F"51 R AAIE RD Cr sw[ NIS 1 INITIAL RELEASE s/m/n kva ,vr• I ABM. O 7HOMA58ERTON swa 7 2 UPDATED TO NEW SCOPE Krim ro ro' Building Value 3 DRAWING CLARIFICATIONS 9/6/17 ro ro f vmw: THOMA58ERTON ABM ELECTRICAL POWER SERVICES 4 LOCATION OF CHARGERS CHANGED W=+ ro TO I VAN WILKINS 152 TECHNOLOGY DRIVE IRVINE, CA 92618 PORT ANGELES INTERNATIONAL GATEWAY TRANSPORTATION CENTER OLYMPIC NATIONAL PARK 123 FRONT STREET PORT ANGELESE, WA 98362 N N I N W A W 00 SNW0 n 0 w wa Tu/W17 I sw[ NIS N i N �•� NTS O swa 7 SNW0 n 0 4.00— )6.00- 2250 .00-16.002250 No. Rvmm 1 INITIAL RELEASE 2 UPDATED TO NEW SCOPE 3 DRAWING CLARIFICATIONS 4 I LOCATION OF CHARGERS CHANGED 30.00 10.00 6.00 t 36.4 i 1� OW DCANDOWSINGL=PORT E XJARDMU M1NGDEtAL(TYPCAL) NT.R. DAM RW D a D A aero uro ABM PORT ANGELES INTERNATIONAL GATEWAYTRANSPORTATION CENTER X0/17 W—F THOMAS BERTON iM OLYMPIC NATIONAL PARK "/17 m ,o Building Value O 9/6/17 ro m nuwx THOMAS BERTON salt tm I Moo NR N ABM ELECTRICAL POWER SERVICES 123 FRONTMEET �""' '� m W�NWILKINC 152 TECHNOLOGYDRIVE PORT ANGELESE, WA98362 o.na IRVINE, CA 92618 ma -m 5� vi 0 w rn 3 "it 10/u/17 O N salt tm I Moo NR N aM[tr V MR. Ii vi STRUCIUML NOTES: G 1913LAU L ALL WOMB SHALL COMFLYWITH THE INTERNATIONAL RUIPINGCOM-CURRENT EDITION, ANDALIOTHERAPPUCAOUF COOESAND REGUTATIWJSOF AGENCIES WWNGJLRISDICNON. 2- ALL REFERENCED STANDARDS REFER TOTHEEDITION IN FORCEATTHETME THESE PLANS AND SPEOFICATONS AREISSUED FOR PERMIT. 3. JOB SAFETY AND PROCEDURES FOR SAFE CONSTRUCTION ARE OF UTMOST IMPORTANCE, AND SHALL BE THE RESPONSIBILTYOFTHE CONTRACTOR. 4. WORK NOT EXPRESSYSHOWN ORSPFLIBICPARTSOFTHE DRAWINGS ORSFEOnCATONS, BUTREASONABLEY IMPLIED BY SUM WORK SHORN, SHALL BE REPEATED. S.CONIRACTORSHIALLBERESPONSBLEFORALL MEMBERS AND MATERIALS TOCONFORMTOACTUALSITECONDITIONS, CONOIAITORSHAM REPORT OFfERINIT SRECONOITIONS PND DEVIATIONSIN NOTED PROMO URET07HE ENGINEER FORREVE W. 6 CONTRACTOR SHALLTAKE EARS TO PROTECT ALL EXISTING STRUCTURES AND UTILITIES FROM DAMAGE. 7. SPEOFICNOM AND DUALS SMALL TAKE PRECEDENCE OVERONERALNOTESANOTYPICALOCTAIS. THE CONTRACTOR SMALL REERMTHE SPECIFICATIONS FOR INFORMATION NOTCOVERED BY THESE GENERAL. NOTES ORTHESTIOCTURAL DRAWINGS. ORAWINGS SHINLTAKE PFIECEDENCEUA R SPE OFICATK M B. IF THEREAPPEARS TO BEA CONFLICT BETWEEN NOTES, DETAILS, ORSPECFICATTON4 CONTRACTOR SHIALLAPPLYTHE MOST RIGID RMUIREMENTSTOTHE WORK. COMMACfOR SHALL NOT DEVIATE FROM DRAWTN65 WITHOUT APPROVAL OFTHE FNGNEER, 9. IT ISTHE INTENTION OFTHIS SET OF DESIGN IRIAWNGSTO PRODUCE comfl 1CTIO NSHOP DRAWINGS FOR THE FABRICATION AND ASSE6LY OF THE BURRING SYSTEMS. THE CONTRACTOR SHALL NROVIDE ALLNECE5SARY REMW NNG COORDINATION, DETAILING AND MISCEUANWUS DESIGN NOT INCLUDED HFREUTANDSHALL VEIFYCDNMWANCE70 ALLDOCAL BULDING COOESANO PROFBSONAL FILING REQUIREMENTS. STRUCTURAL UESIBN MTA: ALL DEAD AND UVE LOADSARE PER THE INTERNATIONAL BUILDING CODES, CURRENT EDITION 1. DEAD IDMS: ALL DEAD LOAOSARE REPRESEMATNE OFACT WL MATERAL WMIT PEU SO. FT. CNNGfA STAND............................._.....43D B9 CONCRETE SW/300PSF 2. LIVE LOADS: ALL LIVE LOADS ARE PER IRC 1607.93; CONTRACTOR TO CONFIRM COMPLIANCE WITH LOCAL BULDING COOTS. VWICULAR IMPACT.....-..........-__........6,COOl9S 4 2'-3' FROM BASE FOMUNDATOAM 1. fOORNGSARE TO NEAR ON M1µ 3ADPSF SUTABLEBEARNG MATERIAL. 2. NOFOOTINGS ARE TO BE CASTON WCONTFIDLE77 FBL, SINK, DROMIC MATERIA, FRIDMN GROUND, MAO, SOFTCLAVS OR OTHER OBCCRONABLE OR UNAPPROVED MATERIALS, CAST IN PUUQCONCREM: L ALL WORK SHALLCOMPLYWITH THE REOUIRFMFNTS OFTHE ACI BUILDIN5 DDIL AQ 314, LATEST EDITION, THEMTOW71ONAL BUILDING CONE, AND ALL ODER APPLICABLE CODES AND REGLLATIM OF AGENCIES HAVING JURISDICTION, DETAILS SHALL BE IN ACCORDANCE WITH ACI -31S, LATEST EDITION. 2. ALL CONCRETE FORCASTHN PLACE YANK SHALL BE 90NECONNTiCTE WITH A MINIMUM 211 DAY COMPRESSIVE STRENGTH OF4,COOPSL 3. NO ADMIXTURES SMALL BEANOWFDWITHOUT PRIOR REVIEW AND ACCEPTANCE W THE ENGINEER. 4. ALL PEOUREMENIS FOR PATCHING, MINN134 FINISHING, CURING ETC. SHALT. BE AS PER ACI 301. LL (E S. AU 94ALLCONFIRMTO ASTM A615GPA13E ESD AND BESEOJRELTTUD IN PLACE AMU AOEOUATTLYSIPPORTED. ALL BARS MARKEDCONTNUOIUS' (CONT.) SHALL BE LAPPED 40 BARDIAMETERS UNLESS OTHERWISE NOTED. IF REOUAED, CONTRACTOR SHALL PRONOEADDMCINAL BWISOR STRRUP'S MADEOWTELY SUPPLORTALL TARS. 61 SHOP ORAWNGS SHALL INDICATE THE FOLLOWING: ALL NECESSARY REINFORCING, LDCATONB OF MLCONSTRUCTION AND CONTROL UONES. DETAILING AND AMOUNT OF REINFORCING FORCONDTIONSNOTSHOWN SHALL BE PROVIDED ASSHDWN IN SIMILAR CONDITIONS. ALL INSERTS AND OTHER DBIECTS WHICH MAY AFFECT PLACING OF REINFORCING BARSSHALL BEINDCATEDON THESHOP DRAWINGS. 7. MINIMUM CLEAR CONCRETE COVER SHALL BE 3', THIS DIMFNSIONSARE TYPLICAU., UNLESS OTHERWISENOIED ON FLANS AND DETAILS B. CONTRACTORSIALL PIOMBERPNFORCING STEELERECTOR WITH A SET OF STRUCTURAL PLANS FOR FIELD USE. 9. CONTRACFORSHALLVUUFV DIMMSONS AND LOCATIONS OF ALL OPENINGS, PIPESLEEVES,CURRIES, EEC AS REQUIRED BY OTHERTRADES BEFORE CONCREMISPLACED. 10. CONTRACTOR LLCOOR13NAYE LOCATION OF SLIMEDLNSERES, WELDED MATES, A14D OTHER ITEMS IO BE IMCODED IN CONCRETE WITH CHARGING STATION MAUFAC:RIPEII. U. CONTRACTOR SHALL USE RIGID TEMPLATES TO INSTALL ANCHOR BOLTS. U. PIPE50RCONDURSNACEONSUABSSHALLWT9ESPACWCWSERtMN3TIMESTFEPIMIEFERDNCMER. PIPES ANDCONWITS PLACED IN STABS SHALL NOTHIAVE ANOUTSIDEDMMEFER LARGER THAN 1/3 OF THE SAB INCRASS. ALUMINUM JDNDUITS SCALL NOTBE PLACED IN CONCRETE NOCONDUTS SNALLOE PLACED INTHE SLAB WITHIN U INCHES OF ANYCOLUMN FACE NO. 24" OAIE DETAIL NOTES: 1 A.1- 2' ROUND SONOTUBE STYLE FORMED BASE TO BE 3/20/17 nRvn Arco POURED FLUSH WITH EXISTING PAVEMENT OR 2 UPDATED TO NEW SCOPE EXISTING FINISHED GRADE M_ TH OMAS SERTON m ro . A.2- STANDARD BOLTDOLNN BOLLARD TO BE INSTALLED O O n ON FRONT OF PAD, SEE BOLLARD DETAIL 10 01 3 A.3- CHARGING STATION PEDESTAL TO BE INSTALLED 9/6/17 m m nw.wM THOMASBERTON PER PEDESTAL DETAILS ABM ELECTRICAL POWER SERVICES 4 I LOCATION OF CHARGERS CHANGED 'TYPICAL WJNS 152 TECHNOLOGY DRIVE CHARGING _ _ STATION IRVINE, CA 92618 PAEDESTAL AAMR 07�-d f j A' d Q .a DETAILNOTES: (GENERAL SEE DETAILS FOR ACTUAL INSTALLATION) Q 8.1- 24" SONOTUBE PIER WITH (4)-#8 VERT. AND DOWELS AND #4 v TIES@ 16" O.C. VERT. .0 ' 8.2- PROVIDE MIN. 24" EMBEDMENT IN SOIL BELOW GRADE A ' NO. REVSKNS OAIE REV AIT' 0 O 1 INITIAL RELEASE 3/20/17 nRvn Arco AA 2 UPDATED TO NEW SCOPE B/ZA7 M_ TH OMAS SERTON m ro . Building Value 3 DRAWING CLARIFICATIONS 9/6/17 m m nw.wM THOMASBERTON ABM ELECTRICAL POWER SERVICES 4 I LOCATION OF CHARGERS CHANGED WJNS 152 TECHNOLOGY DRIVE -- I _ _ EVAN _ I _ IRVINE, CA 92618 7 PORT ANGELES INTERNATIONAL GATEWAY TRANSPORTATION CENTER OLYMPIC NATIONAL PARK 123 FRONT STREET PORT ANGELESE, WA 98362 111A O w W W wu DJ/32/17 I soul NTS Cr -j 1 I N wa NIS O V $MIT 9 smut U N Rn NO. 1 2 3 a TRENCH DETAIL. / N.T.S. 'PROTECTIONDOLLARDEMBFDOEDOR DOLTOOWN67MEDEPENDINGON fLOC,ATION / AND NIJI'$VANIZEQ DOLTS. WASHERS, /rExISTING GRADE -__�t _ __ /"' •. C f4' CONCRETE SURFACE _ __..__ - I . OR ASPHALT LAYER 21. a6. \ \ ' , \`.,` / ; l/ , _ __ CONCRETE RASE az xaD xix tLPWQRWMYDASEO MNQ°tt AMAQCau3fD3TOWnix2M ExxlLNG PAVED OR CONCRETE -------.._._ N.T.S. SMN ..A REVKIDw 1__, -TRENCH WALL 1-G" 41--l" -EARTH OR STONE SAND �` MIN ''.�\;,\,\� - BACKFILL MIX TAMPED AT 4' LIFTS OR CRUSHED STONE BACKFILL. 3' MAX UPDATED TO NEW SCOPE -SAND Z'``"'�"''%�� ••+;:,' --ELECTRICAL, CONDUIT 6, --SAND OR CRUSHED STONE BASE LAYER arcaTn-YA"!.1KKlUNi Cii.YAPMIC ST TMAX_...__._.._..._._.� MAXIMUM AREA DISTURBED 36' DEPTH x 36" WIDE TRENCH DETAIL. / N.T.S. 'PROTECTIONDOLLARDEMBFDOEDOR DOLTOOWN67MEDEPENDINGON fLOC,ATION / AND NIJI'$VANIZEQ DOLTS. WASHERS, /rExISTING GRADE -__�t _ __ /"' •. C f4' CONCRETE SURFACE _ __..__ - I . OR ASPHALT LAYER 21. a6. \ \ ' , \`.,` / ; l/ , _ __ CONCRETE RASE az xaD xix tLPWQRWMYDASEO MNQ°tt AMAQCau3fD3TOWnix2M ExxlLNG BOLLARD DETAIL -------.._._ N.T.S. SMN ..A REVKIDw DALE IW APY 1 a D INITIAL RELEASE 3/m/27 aero Am '1 EVITt1GCffa1. FlSDtJSC7aWDf .1 THOMAS BERTON UPDATED TO NEW SCOPE BM17 m — i DRAWING CLARIFICATIONS 9/6/17 m — nrin THOMAS BERTON LOCATION OF CHARGERS CHANGED WW17 m Tes arcaTn-YA"!.1KKlUNi I ..—SIDDhL4a4T8d°I. ieanN �........................ _ -------.._._ Iz a SMN ..A 91 TCPCFFfEro1POVftT7 .. _-�xcaTER�slsLotlty 6. Ir- 2) FfWiEttESGNlQEN.HE!TVFiaCi Pafccaar:ICNwTIloaxta '1 EVITt1GCffa1. FlSDtJSC7aWDf .1 OTY0 "DIAMETERSTAINtES55TEE1 i m��acAa�c��1aE'�rn� E f ftA"iiPLn4TDltF,TNIATC" sMix Cii.YAPMIC ST I ..—SIDDhL4a4T8d°I. ieanN -..CYtJ:J'f1EFiX7ttG -------.._._ ��.••—_,•----'' SMN ..A 91 TCPCFFfEro1POVftT7 6. Ir- 2) FfWiEttESGNlQEN.HE!TVFiaCi MVQ34,W�-ARR.iIFCfO:tt[};�t11,:t701d[E '1 SIGN POLE DETAIL .1 N.T.S. ABM. 6uildIngValue t ARM ELECTRICAL. POWER SERVICES 252 TECHNOLOGY DRIVE IRVINE, CA 92618 PORT ANGELES INTERNATIONAL GATEWAY TRANSPORTATION CENTER OLYMPIC NATIONAL PARK 123 FRONT STREET PORT ANGELESE, WA 98362 A N to I ko I V A O 10,12/17 O N SCF NTS O I N Iai tm O V —a 10 $wo♦ 12 Parking Site Guidelines and Layout Two Parallel Parking Space Location Angled or straight Single Parking Location (One charger serves two parking spots) Angled or straight Parking 36" Fixed Carbon Steel Bollard rounded top, with 4-3/4" Outside Dia., Safety Yellow Bolted to each pad to protect the charger and allow snow plowing of space(northem Climates) I i 0 0 Wheel Stop Dollard EVSE/Charger Cho: Part Pavement marking, wheel stops and bollards and, if it fits into the overall site appearance, also curbs have to be painted in RAL 6026 (opal green). • The marking of the EV -Charging parking spot has to be prioritized over existing markings. If there Is any striping in different colors, it has to be painted over with the opal green color. Stencils to be used for marking to be found below, Dimensions: EV -Symbol: 36 in x 36 in on a 38 in x 38 in green background frame . 'EV Charging only' and'Electrical Vehicle Charging only' according to California Code: Figure 3B-108 (CA) Electric Vehicle Charging Station Pavement Marking Pavement marking Details (Sheet 1 & 2) example Where there Is no curb, wheel stops are an alternative. 72"x 6" x 3" Plastic, 20 lbs., maintenance free, no painting 1 EW; 1j 11.' T i.: MAN UP rEh4 m5"•' lY )"E. EV•Symbol,,tobemarked In white on green background For parallel parking boys For angled or straight panting bays Where there Is no curb, wheel stops are an alternative. 72"x 6" x 3" Plastic, 20 lbs., maintenance free, no painting A N U'I I ifl I J A RESERVER PARKING No. RwaKM oArr RW 0 APP 0 1 INITIAL RELEASE 3/ia/17 aero caro ABM, gym, THOMAS BERTDN - M2 2UPDATED TO NEW SCOPE ami1I I m m Building Value 3 DRAWING CLARIFICATIONS 01611-11 to no MW THOMAS BERTDN ABM ELECTRICAL POWER SERVICES 9 4 LOCATION OF CHARGERS CHANGED (wrrrnr rn m VAN WKKIN C 152 TECHNOLOGY DRIVE _ IRVINE, CA 92618 A N U'I I ifl I J A PORT ANGELES INTERNATIONAL GATEWAYTRANSPORTATION CENTER OLYMPIC NATIONAL PARK 123 FRONT STREET PORT ANGELESE, WA 98362 Ma 10712/17 0 N rrau NIS 0) I N ae fm O J racer 11 sxene R t A N RESERVER PARKING CD WALLMOUNTED y OR POST MOUD EV PARKiNGSIGNAGE ONLY 1 PORT ANGELES INTERNATIONAL GATEWAYTRANSPORTATION CENTER OLYMPIC NATIONAL PARK 123 FRONT STREET PORT ANGELESE, WA 98362 Ma 10712/17 0 N rrau NIS 0) I N ae fm O J racer 11 sxene R t A N RECIlUCAL -BASIC IE OUIiFM IM L Pnvidtal labor, makedab, newssary aquipment and smuces In turnpikes al required Eletrkal Wash indudiytas adddonai hems required for a mmpkto and proper Inaalanon as Idkatd on the Dravd nes or as nqubed. Illsnk inebtlesbu Is not witch to tie" wig. k Sevkeentrarce system. B. AII%M l erdcompoaena to the chuging yaems L lotsitetion shag be in accordance with the latest dkbn ofthe NatbrolEketrlral Cede ardA4 apllkalloregdatlms otgowerrdgt basal, Stake, County and Federal Cades Includry Utlkey Corepadq spial reglkemenls. 3. Inthe event d 4codktbtween &VINnent redrawn and then VdlOt M the morsstrhgatt ITIBIU mmtswti beappicabk. 4. Courdrsde delivery aadinstallation oiegrhpmerc required undertlitSettbn W ththeconstrtcnon sehdds. S. Cowdrote wotkwkhdFat trades awl drawings & Allmateblsdndibe new, kat ofdeleas and shag he U.t_ Istel, borinjU.1. bbd orbolsbebd arIbted with an appesved nadondly tetaEMtd ElairkaiSest(rgAgqny. 7. MAN that connections hexa en ail g*apperf Aenlshd utdatliscartrad. & the Contractor stet check LI dlmendonsadvady ape conddon , peaahhktothawbrawlewatit* braldkgand site and she# rears any darepo rdas orcondtba hears dab 10 MerW o proper cenPlektn olmskto tie Enghew of arse. & CNekdyoraMtte an prefect CrawretpIncluded lex tNe Contract and these Included ender odvar rantracn and report mydkcreposcle to Engineer and ArdnkawL 10. Wet tosmedl sola oftkawhp, It is not podbleto Indicate all offsetA, AunnIM a Nesspareak and sM/a Peru whithmay berequited. DMWW we pterdMlydlodNe of velem he fretatkd. Carek9yaarrina itnkWtd aadthlsln condtlons alfasthitwokand araga aRvrdr arswdhyhr, (urdsNgt mamarypsns ad equlpnea a maybe regdredo meet amW gddrodhio a, 11.bayodwoktmmdm rsiutsdApbk= Wad Strctual DavArp and actual dknentlonsof e0dprowt beegirnaikd La trues becongated am" "not be naked heormechadW and Oedrkal Ora vlo i. Do rat rmke Arid saccus unif Shop Car Bwonvern tkawhp We sprroved andlobven ldonseedAed. 12. The dght is retorted w make aryraeonabir'hop 1. locations d equipment and slmlartarns wkNhths ptdNhl and at building ssterku,pitato ietala rat w1vaep, ksedvhq addnonal cernpemabn. 13. All corcreto saw Mtlnd removed and pnddryl to be included 14. Allwonk shown on Or vamp skew be u0plereented by all taws. Ordranees peed Codet4mrwn is the—titthaw DMbiorn,wNdr taws. Ordrances or Codes shelf take precedence in the event ofamconMd between same except where eredteds or noterlah sloven are superk rto thelegaldegeir mens. 15. train 29 "quirad cenitkateslmmGwwoktgAptwy andaeno¢rtoort, attsrmpiatlandtirorL tabour, wactdwrkes torten, perms, and otter wdsrequired and hcludtuuhameota m &d Ifikka 19. Contractor shat provide awarranty suMt entlatlnnthat,l Material mss hack sadtkrd and thatheshaif repairer replace arty deductive va mals awoetmw 4dil In in steel&" master, without cost to the Ownw. INaeaoW peril shall be leu see(ltvarunWsrpectlidlonprtoapusgkagdptrnest Dao dwarramydart stall be from st6stamaleortpktba and bmehdalun. 11. Contractor will obtain abuldryd parent or hit portion of the WOOL Ile. Ceetracorta provkdepgcb pane and penetrations required for ekarkal its" witch pierce roof whetter or sot anter, an Drawkep. It. Contractor to Etankh and Instal rehforted oorcreta pads fer elupmot as mw'wed. 70, Inleneal, alllh*f aqutp erenth o be toppled and amuhlmred byEms aaamfA mta, but mud be eubohad ad approved epalto that sperg/ed. 21, tarata aiiopeenli preWr dfor Work porhondtnder thls soctbrt Peruda skews, guards or ower ater wel metfodsto allow pump d gemsInstalled under 0* sadms 72. pawkiesoekhd supply within 36° olequipaunt emptied and hndald IN other contractors. Mo erstaran andmdrds will be podded by othen(eavept where n4bal) to be install bytha OsariaiCorfrator. 23. Whenever the Camraaorproddapow conurnhR equipe ttar"diffarsfmontmbsct Dovemesti, thesvith/ aced saodateddretd cmrpmens IN suchmepmant deed be etwited to proal sit ato makh at adadand aeareeto Owner. 24. N Is the Cant radar's ngondmihyta Mwdinane the aspect raqufod location of floor cudats, Ram duca, nowl,wh�;al dr, wkhONWandAKhtMadreceNeeiOcwapdatortar NM Inc -dents downon, pbns eo artyaPprsslmate i0c"M. ELECIIIICAL- GENFIW. KOUIREMENIS A. vilmstssaro on TNWR wborl"abd othInweton Drawhgs orSrhdeia or iftake else it recused AN vadmontArnbhed. 2. Cdeshed grompspndra raodrav Is to be FwAded far al branchd2ub. 3. Pmvdecahk stein tafdortankrsitosts. IrAwfaccess panels %hem requhd. 4. Coordaate powerbtakms with owner. S Coordrote w Ith atter subs if oqubed forcer plete, proper operation and hstaletlon of as equipment. & Mu0saetion brans cIrtukparUllao hweshownas intlkidud panabanpetsd schaldes. prttrRmunitahjindkaad on dravdnp rdkd wase:nke Nn~rr for single paned. FIECTRICAh. - GENERAL CONSTRUCRON NOFES 2. Oahkah Contractor *0 twrdn tt the work with other trades Inodartoavodcnrdka. L the mlmaum mrduk da shalt to III'. 3. Voltage drop mhirnar; VAN ddni (IDA devil) un - L 12Wcisnitover SWUseOnodtknwn 2. 206V drwt war ID7 Use #10 mhknwn I 2m dmk rare 209' cove peso mmkmm AOdmum branch cboak wive ala shall be iii. 4. AlhopmhnpIn fee rated wells, loorand adkkmsfal tmdalb dui be salad with quo awAn ant town per UL approved"Flee Stop" system to saelf"In the tie rdksq. S.AUwidrivs/beln"Wcabteabycode. Ursinvound ttadutwll be Schad 40 PVCvsth (Inhip, conduit ab crearade baaledistabk EMF, & Edurcttkd Cantruor shag havetie opbnoffXosDkn{ Acsnvtats hone cendrn, Wrtle rsgdcemonts at S:stbn 310 of the Nadoral 11scakai Coda. t1EMCAI. - GENERAL RELIGIIE MEMS & Mew mnpany test by of rcm 9. Nltkcults hdimtedan these dowbtas are IDA, IP dm* bmakersIn puubunkss otherwise noted, W. Ndsand h, shallbs i vialled apoved In was Wan tathe pullk >I.Ouda Meta for reaptsdes sW k h,mketnked 18° shove Rdsh Sisk udess noted othervsn, 1i. Aiditrmdonslndkatdm to cenker{Lneof Hrcebn tones, A00TIUea,RUL, wdeoahwwlverated. Rthrtolnkeda Mewingsforaidansoview 15, the woad "prowids`"fuer, °taArnlsh and tsnstair, 16. A.F.F.. Above Finished Floor U.N.O. = Unless Wed Otherwise G.E.C.. BUldok ONVI W Contractor F.C. a Ebttre Coraradat Its. Aflt6tOF1i DATE REV APP' D o PORT ANGELES INTERNATIONAL 1 INITIAL RELEASE 3I2D/17 awe. GATEWAY TRANSPORTATION CENTER aeane THOMAS BEATON nit OLYMPIC NATIONAL PARK 2 ( UPDATED TO NEW SCOPE g1291S7 r� 'ex Building Value 8 DRAWING CLARIFICATIONS 9/11/17 m m teaw-_ THOMAS BERTON ARM ELECfRICAI. POWER SERVICES 223 FRONTSTREET 4 LOCATION OF CHARGERS CHANGED -- ren to 152 TECHNOLOGY ORIV E PORT ANGELESE, WA 98362 ' M I a rape.-YdM W1LKJ91S IRVINE, CA 92618 Q A N A Gtv "CI twit W/12/17 q I VAN NFS ! N cess FITS O V 6.w Iz woos U sr,