HomeMy WebLinkAbout1105 Dunker Drive Address:
1105 Dunker Drive
PREPARED 6/18/15, 10:30:02 INSPECTION TICKET PAGE 5
CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 6/18/15
——--------------------------------------------------------------—------------------------ '-
ADDRESS . : 1105 DUNKER DR SUBDIV:
CONTRACTOR ACE MICHAELS INC PHONE (360) 460-6172
OWNER ACE MICHAELS INC PHONE (360) 460-6172
PARCEL 06-30-01-8-3-0150-0000-
APPL NUMBER: 15-00000051 RES NEW SFR
PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
---------- ——-------—-------------------------------—----------
BL1 01 2/20/15 JLL BLDG FOUNDATION FOOTING
2/20/15 AP February 20, 2015 4:26:26 PM pbarthol.
February 20, 2015 4:51:25 PM pbarthol.
BL2 01 2/24/15 JLL BLDG FOUNDATION STEM WALL
2/24/15 AP February 24, 2015 9:45:34 AM pbarthol.
Mike 460-6172
Late afternoon
February 24, 2015 4:12:16 PM jlierly.
EFF O1 3/10/15 PB BLDG FLOOR FRAMING
3/11/15 AP March 10, 2015 9:59:52 AM pbarthol.
Mike 460-6172
March 11, 2015 11:33:00 AM pbarthol.
BL9 01 3/24/15 JLL BLDG SHEARWALL
3/24/15 AP March 24, 2015 1:17:46 PM pbarthol.
March 24, 2015 4:41:58 PM jlierly.
BAIR O1 4/09/15 JLL BLDG AIR SEAL
4/09/15 AP April 9, 2015 12:38:30 PM pbarthol.
Mike 460-6172
April 9, 2015 4:18:39 PM jlierly.
BL3 01 4/09/15 JLL BLDG FRAMING
4/09/15 AP April 9, 2015 12:38:55 PM pbarthol.
Mike 460-6172
April 9, 2015 4:18:39 PM jlierly.
PW99 01 5/22/15 RV PUBLIC WORKS FINAL
5/26/15 AP May 26, 2015 11:38:32 AM rvess.
May 26, 2015 11:38:54 AM rvess.
FFNL O1 6/01/15 KDD FIRE FINAL
6/01/15 AP June 1, 2015 4:43:26 PM kdubuc.
June 1, 2015 4:43:54 PM kdubuc.
BL99 01 6/18/15 BLDG FINAL
June 18, 2015 10:24:58 AM jlierly.
`\ Mike 460-6172
--------------------------�-J---------------------------------------------------------------------
PERMIT: ME 00 MECHANICAL PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
--------------—---------------------—--------------------------------------------
MEI O1 4/09/15 JLL MECHANICAL ROUGH-IN
4/09/15 AP April 9, 2015 12:39:21 PM pbarthol.
Mike 460-6172
April 9, 2015 4:18:39 PM jlierly.
ME99 01 6/18/15 LL MECHANICAL FINAL
i
June 18, 2015 10:25:21 AM jlierly.
U
PERMIT: PL 00 PLUMBING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
-------------------------------------—---—--------------------------------------—-----------
------—--------—----------------- CONTINUED ONTO NEXT PAGE -----------------------------------
PREPARED 6/18/15, 10:30:02 INSPECTION TICKET PAGE 6
CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 6/18/15
---------------------------
ADDRESS . : 1105 DUNKER DR SUBDIV:
CONTRACTOR ACE MICHAELS INC PHONE (360) 460-6172
OWNER ACE MICHAELS INC PHONE (360) 460-6172
PARCEL 06-30-01-8-3-0150-0000-
APPL NUMBER: 15-00000051 RES NEW SFR
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
PL6 01 3/27/15 JLL PLUMBING WATER SUPPLY
3/27/15 AP March 27, 2015 9:12:40 AM pbarthol.
March 27, 2015 4:05:22 PM jlierly.
PL2 01 3/30/15 JLL PLUMBING ROUGH-IN
3/30/15 AP March 30, 2015 9:11:30 AM jlierly.
March 30, 2015 4:11:59 PM jlierly.
PL99 01 6/18/15 �J➢L PLUMBING FINAL
�111 _ June 18, 2015 10:25:34 AM jlierly.
----------------------V_ COMMENTS AND NOTES
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT- BUILDING DIVISION
®� 321 EAST 5TH STREET, PORT ANGELES, WA 98362
QN,
Application Number . . . . . 15-00000051 Date 2/19/15
Application pin number . . . 817103
Property Address 1105 DUNKER DR
ASSESSOR PARCEL NUMBER: 06-30-01-8-3-0150-0000- REPORT SALES TAX
Application type description RES NEW SFR on your state excise tax form
Subdivision Name . . . . . .
Property Use . . . . . . . . to the City of Port Angeles
Property Zoning . . . . . . . RS9 RESDNTL SINGLE FAMILY (Location Code 0502)
Application valuation . . . . 132525
---------------------------------------------------------------------------- -
Application desc
1849 sq ft singel story sfr
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
ACE MICHAELS INC ACE MICHAELS INC
1329 W 10TH ST 1329 W. 10TH ST.
PORT ANGELES WA 98363 PORT ANGELES WA 98363
(360) 460-6172 (360) 460-6172
----------------------------------------------------------------------------
Permit . . . . BUILDING PERMIT -RESIDENTIAL
Additional desc 1849 SQ FT SFR
Permit Fee . . . . 1205.05 Plan Check Fee 783.28
Issue Date . . . . 2/19/15 Valuation . . . . 132525
Expiration Date . . 8/18/15
Qty Unit Charge Per Extension
BASE FEE 1020.25 0
33.00 5-6000 THOU BL-100,001-500K (5.60 PER K) 184.80
------------------------------------- ------
Permit . . . . . . MECHANICAL PERMIT
Additional desc . . SFR MECHANICAL
Permit Fee . . . . 97.20 Plan Check Fee .00 C
Issue Date . . . . 2/19/15 Valuation . . . . 0
Expiration Date 8/18/15
Qty Unit Charge Per Extension c�
BASE FEE 50.00
3.00 7.2500 EA ME-VENT FAN (SINGLE DUCT) 21.75
1.00 10.6500 EA ME-HOOD/DUCT-MECH. ..EXHAUST 10.65
1.00 14.8000 EA ME-HEATER(SUSP/WALL/FLOOR-MTD) 14.80
-
---------------------------------------------------- --------------- -------
Permit . . . . . . PLUMBING PERMIT
Additional desc SFR PLUMBING
Permit Fee . . . . 149.00 Plan Check Fee .00'
Issue Date . . . . 2/19/15 Valuation . . . . 0
Expiration Date 8/18/15
Qty Unit Charge Per Extension
BASEFEEFEE 50.00
7.00 7.0000 EA PL-PLUMBING TRAP 49.00 In
1.00 7.0000 EA PL-WATER LINE 7.00
3.00 7.0000 EA PL-DRAIN VENT PIPING 21.00
1.00 15.0000 EA PL-SEWER LINE 15.00
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
i
BUILDING PERMIT INSPECTION RECORD
PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS —
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-In
Water Line(Meter to Bldg)
Gas Line
Back Flow/Water FINAL Date Accepted b
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall Interior Braced Panel Onl
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pum /Furnace/FAU/Ducts
Rough-In
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts FINAL Date Accepted b
MANUFACTURED HOMES:
Footing/Slab
,Blocking&Hold Downs
Skirting
PLANNING DEPT. Separate Permit#s SEPA:
Parkin /Lighting ESA:
Landscaping SHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction- R.W. PW /Engineering 417-4831
Fire 417-4653
Planning 417-4750
Building 417-4815
T:Forms/Building Division/Building Permit
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT- BUILDING DIVISION
® 321 EAST 5TH STREET, PORT ANGELES, WA 98362
Page 2
Application Number . . . . . 15-00000051 Date 2/19/15
Application pin number . . . 817103 REPORT SALES TAX
Qty Unit Charge Per Extension on your state excise tax form
1.00 7.0000 PL-WATER HEATER 7.00
-- to the City of Port Angeles
Special Notes and Comments (Location Code 0502)
February 11, 2015 7:39:09 AM rbecker.
If the fire sprinkler system is a closed system, you will
need to install a double check valve assembly. If the fire
system is an open system, you do not need to install a
backflow.
If you have any questions, call Ron Becker at 360-417-4886,
fax:360-452-4972, or E-mail: rbecker@cityofpa.us
Address numbers shall be plainly visible from the street.
.Address numbers shall be a minimum of six inches high and be
of contrasting color from the background.
All homes in new subdivisions that are outside of the Fire
Department four-minute response area shall be equipped with
residential fire sprinkler ,systems that comply with the
International Fire Code (IFC) and National Fire Protection
Association (NFPA) .
This project will require seperate permit and fire
sprinkler plans for review.
A full acceptance test will be required for the fire
sprinkler system.
Call for cover inspection for all sprinkler installations.
Electrical load calculations and electrical permits are
required.
1) Standard Stormwater Comments for temporary erosion
control. Part of a larger plan of development.
This includes:
1. Mark Clearing Limits
2. Establishing Construction Access
3. Control Flow Rates
4. Install sediment controls BMPs.
5. Stabilize exposed soils
6. Protect slopes from erosion
7. Protect drain inlets
8. Control pollutants including but not limited to spills,
concrete wash out, exposed aggregate processes, concrete
grinding and saw cut waste water.
9. Maintain temporary and permanent erosion control BMPS
during project
10. All disturbed soils on site shall be amended to meet
soil quality and depth BMP T5.13
No downspouts shall be connected to sanitary sewer.
Consider applying for the City Green Infrastructure Rebate
of up to $750.00 towards the materials to install rain
garden to control roof and driveway runoff. Also rebates
available for downspout disconnections.Contact Jonathan
Boehme at 360 417-4811
Trench safety per applicable laws. Temp erosion control and
surface restoration responsibility of applicant. Contact
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
J
BUILDING PERMIT INSPECTION RECORD
PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS —
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-In
Water Line(Meter to Bldg)
Gas Line
Back Flow/Water FINAL Date Accepted b
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall Interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pum /Furnace/FAU/Ducts
Rough-In
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts FINAL Date Accepted b
MANUFACTURED HOMES:
Footing/Slab
.Blocking&Hold Downs
Skirting
PLANNING DEPT. Separate Permit#s SEPA:
Parkin /Lighting ESA:
Landscaping SHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction- R.W. PW /Engineering 417-4831
Fire 417-4653
Planning 417-4750
Building 417-4815
T:Forms/Building Division/Building Permit
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT- BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES, WA 98362
Page 3
Application Number . . . . . 15-00000051 Date 2/19/15
Application pin number 817103 REPORT SALES TAX
Special Notes and Comments on your state excise tax form
City inspector prior to start of work @ 360 417-4831. No
attachment to sanitary sewer of stormwater roof leaders, to the City of Port Angeles
foundation drains, yard drains, or any other CSO (Location Code 0502)
contribution is allowed.
Sanitary sewer connection inspection is required by
Public Works prior to back fill of ditch. 24 hour advance
notice is required. Public Works Inspection request line
417-4831
The contractor making the connection to an existing water
meter is responsible to adjust water meter depth so that
there is a minimum of 4 to 6 inches of clearance between the
bottom of the meter box lid and the top of the meter at
finish grade.
Use existing driveway opening.
-------------------------------- -------------------------------------------
Other Fees . . . . . . . CITY DRA °s 77.83
DRA FEES PLUS INTEREST 2236.60
RES UNDERGRND SERVICE FEE 770.00
SEWER SYSTEM DELV CHARGE 2260.00
STATE SURCHARGE 4.50
PW WATER SYSTEM USE FEE 2260.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 1451.25 1451.25 .00 .00
Plan Check Total 783.28 783.28 .00 .00
Other Fee Total 7608.93 7608.93 .00 .00
Grand Total 9843.46 9843.46 . .00 .00
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
BUILDING PERMIT INSPECTION RECORD
-- PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS —
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-in
Water Line(Meter to Bldg)
Gas Line
Back Flow/Water FINAL Date Accepted b
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall Interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pum /Furnace/FAU/Ducts
Rough-In
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts FINAL Date Accepted b
MANUFACTURED HOMES:
Footing/Slab
Blocking&Hold Downs
Skirting
PLANNING DEPT. Separate Permit#s SEPA:
Parkin /Lighting ESA:
Landscaping SHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction- R.W. PW / En ineerin 417-4831
Fire 417-4653
Planning 417-4750
Building 417-4815
T:Forms/Building Division/Building Permit
THE � � For City Use
CITY OrN�GEIFSP-- A)
Permit# O
W AS HI N G r a N, U . S. Date Received: / d 45�
321 E Sth Street
Date Approved r ,f, , /p �
Port Angeles,WA 9836
P:360-417-4817 F: 360-417-4711 s
Email:permitsc@cityofpa.us BUILDING PERID I APPLICATION
Project Address: Q vt�1L,,� Nk`, L
( � n Phone: 6 o �, j—7-�
Prima Contact: M X14 - Email: W1 \4.C. A c L&k-Z L N A SQ C,
Name Phone
Property Mailing Address 1 Email
Owner l 3 a I1�e c� I U` S l
City (�,n /� State Zip
Nam Phone
Contractor Addr s c Email
Information city State zip
Contractors License# Exp.Date:
Legal Description: Zoning: Tax Parcel # Project Value: (materials and labor)
1—car /Z' 414,✓ $ .30
ResidentialCommercial ❑ Industrial ElPublic El
Permit Demolition ❑ Fire ❑ Repair ❑ Reroof(tear off/lay over) ❑
Classification For the following, fill out both pages of permit application:
(check New Construction Exterior Remodel ❑ Addition ❑ Tenant Improvement ❑
appropriate) g
Mechanical ElPlumbin ❑ Other ❑ i
Fire Sp ,inkier System? Irrigation System? Proposed Bathrooms Proposed Bedrooms
Yes No E3 Yes ® No ®
Project Description NL,-) '1�• '� (126�� �/�'
Is project in a Flood Zone: Yes ® NoJ& Flood Zone Type:
If in a Flood Zone, what is the value of the structure before proposed improvement? $
I have read and completed the application and know it to be true and correct. I am authorized to apply for
this permit and understand that it is my responsibility to determine what permits are required and to
obtain permits prior to work. I understand that plan review fees are not refundable after review has
occurred. I understand that I will forfeit review fees if I withdraw the application before the permit is
issued. I understand that if the permit is not picked up/issued within i8o days of submittal,the application
will be considered abandoned and the fees will be forfeited.
Date l 16 Print Name � - A\ Z— Signature
Residential Structures
For Office Use
Area Description(SQ FT) Existing Proposed $$value
Basement
First Floor l y o
Second Floor
Covered Deck/Porch/Entry
Deck(over 30"or a° floor) 3 ,/,//
Garage
Carport
Other(describe)
i
Area Totals
Commercial Str`uet'urres
For Office Use
Area Descriptions(SQ FT) Existing Proposed $$Value
i
Existing Structure(s) /
Proposed Addition
r
Tenant Improvement?
Other work(describe)
Site Area Totals
Lot/Site Coverage Calculations
Lot Size (sq ft) Lot Coverage(sq ft) %Lot Coverage(To al lot coverage_lot size)
13 �c� 4-'/ 0
Site Coverage (Sq Ft f all im ervious) - %of Site Coverage (total site coverage-lot size)
6
Mechanical Fixtures
Indicate how many of each type of fixture to be installed or relocated as part of this project.
Air Handler Size: # Haz/Non-Haz Piping Outlets:
Appliance Exhaust Fan # 4� Heater(Suspended,Floor, Recessed wall) #
Boiler/Compressor Size: # Heating/Cooling appliance #
re air/alteration
Evaporative Cooler(attached,not # Pellet Stove/Wood-burning/Gas #
portable) Fireplace/Gas Stove/Gas Cook Stove/Misc.
Fuel Gas Piping #of Outlets: Ventilation Fan,single duct #
Furnace/Heat Pump/ Size: # Ventilation System #
Forced Air Unit
Plumbing Fixtures
Indicate how many of each type of fixture to be installed or relocated
Plumbing Traps # Fuel gas piping #of Outlets:
Water Heater # Medical gas piping #of Outlets:
Water Line # Plumbing Vent piping #
Sewer Line # i Industrial waste pretreatment
1
interceptor Grease Trap) Size
Other(describe):
T:\BUILDING\APPLICATION FORMS\Current BP Application\Building Permit4.17.13.docx
(\C,
D ,
Y-0-
IN
-0-1
co v onto
I
Itio � S�• 5--�
F�oJ�
17
o�
To ate\
J
T
lYJ
�3
d "
30- d
i
1015
.^ 1009 ..
m 1020 J
v
1015 s
1006
1021
„ r 1010
t
t
1;27
4 1014 ,
1104 t y'* s .„x
�r v
a a Y tet. l
6 Y `� A.^fY •qM / ,*
4
q p
1105
a 1103
�x w
.,,�� '+raw, ,.:,. .. . .. � w q ,.a, �,.�. �'� `�'°"^•.t'
m
1109
2311
s
2307
Prescriptive Energy Code Compliance for All Climate Zones in Washington
Project Information Contact Information
This project will use the requirements of the Prescriptive Path below and incorporate the
the minimum values listed. In addition, based on the size of the structure,the appropriate
number of additional credits are checked as chosen by the permit applicant.
tt _ k:
Table R402.1.1 Footnotes
For SI: 1 foot .= 304.8 mm, ci .= continuous insulation, int .= intermediate framing.
a R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity which is
less than the label or design thickness of the insulation, the compressed R-value of the insulation from
Appendix Table A101.4 shall not be less than the R-value specified in the table.
b The fenestration U-factor column excludes skylights.The SHGC column applies to all glazed fenestration.
Exception: Skylights may be excluded from glazed fenestration SHGC requirements in Climate Zones 1
through 3 where the SHGC for such skylights does not exceed 0.30.
1110/15/21.+TB" means R-10 continuous insulation on the exterior of the wall, or R-15 on the continuous
insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the
basement wall at the interior of the basement wall. "10/15/21.+TB" shall be permitted to be met with R-13
cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or
exterior of the wall. "10/13" means R-10 continuous insulation on the interior or exterior of the home or R-
13 cavity insulation at the interior of the basement wall. "TB" means thermal break between floor slab and
basement wall.
d R-10 continuous insulation is required under heated slab on grade floors. See R402.2.9.1.
e There are no SHGC requirements in the Marine Zone.
f Basement wall insulation is not required in warm-humid locations as defined by Figure R301.1 and Table
R301.1.
g Reserved.
h First value is cavity insulation, second is continuous insulation or insulated siding, so "13.+5" means R-13
cavity insulation plus R-5 continuous insulation or insulated siding. If structural sheathing covers 40 percent
or less of the exterior, continuous insulation R-value shall be permitted to be reduced by no more than R-3
in the locations where structural sheathing is used to maintain a consistent total sheathing thickness.
The second R-value applies when more than half the insulation is on the interior of the mass wall.
For single rafter-or joist-vaulted ceilings, the insulation may be reduced to R-38.
k Int. (intermediate framing) denotes standard framing 16 inches on center with headers insulated with a
minimum of R-10 insulation.
Log and solid timber walls with a minimum average thickness of 3.5 inches are exempt from this insulation
requirement.
Table R402.1.3 Footnote
a Nonfenestration U-factors shall be obtained from measurement, calculation or an approved source or as
specified in Section R402.1.3.