HomeMy WebLinkAbout1108 Cathleen Street Address: 1108 Cathleen Street a. PREPARED 6/20/16, 8:57:23 INSPECTION TICKET PAGE 2 CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 6/20/16 ------------------------------------------------------------------------------------------------ ADDRESS . : 1108 CATHLEEN ST SUBDIV: CONTRACTOR : PHONE OWNER GARY ST LUISE II PHONE PARCEL 06-30-01-7-7-0060-0000- APPL NUMBER: 16-00000426 RES DETACHED GARAGE ------------------------------------------------------------------------------------------------ PERMIT: BPR 00 BUILDING PERMIT - RESIDENTLAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ BLFW O1 4/19/16 JLL BLDG FOUND FTG/STEM WALL 4/19/16 AP April 19, 2016 9:22:28 AM jlierly. Mike 460-6172 April 19, 2016 4:37:15 PM jlierly. BEXS O1 5/31/16 JLL BLDG EXTERIOR SHEETING 6/01/16 AP May 27, 2016 8:37:54 AM jlierly. June 1, 2016 9:24:36 AM jlierly. BL3 01 5/31/16 JLL BLDG FRAMING .6/01/16 AP May 27, 2016 8:37:09 AM jlierly. Jerry 460-2122 June 1, 2016 9:24:36 AM jlierly. BL99 01 6/20/16 LL BLDG FINAL June 20, 2016 8:48:28 AM jlierly. Gary 509-669-0004 -------—--—------------------------- COMMENTS AND NOTES -------------------------------------- �� CITY OF PORT ANGELES �1i� DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT- BUILDING DIVISION 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Application Number . . . . . 16-00000426 Date 4/15/16 Application pin number . . . 711956 Property Address . . . . . . 1108 CATHLEEN ST REPORT SALES TAX ASSESSOR PARCEL NUMBER: 06-30-01-7-7-0060-0000- Application type description RES DETACHED GARAGE on your state excise tax form Subdivision Name . . . . . . to the City of Port Angeles Property Use . . . . . . . . Property Zoning . . . . . RS9 RESDNTL SINGLE FAMILY (Location Code 0502) Application valuation . . . . 17280 ---------------------------------------------------------------------------- Application desc ADDING A 18'X32' DETACHED GARAGE ---------------------------------------------------------------------------- V Owner Contractor ------------------------ ------------------------ GARY ST LUISE II OWNER 1108 CATHLEEN ST PORT ANGELES WA 98362 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT -RESIDENTIAL ew ',Additional desc DETACHED GARAGE 18'X32' ,Perm it Fee . . . . 319.75 Plan Check Fee 207.84 -;�_ ,Issue Date . . . . 4/15/16 Valuation . . . . 17280 Expiration Date 10/12/16 Qty Unit Charge Per Extension 0 BASE FEE 95.75 16.00 14.0000 THOU BL-2001-25K (14 PER K) 224.00 -------------------------------------=-------------------------------------- Special Notes and Comments ' The Fire Department has reviewed the project application and has no comments April 6, 2016 3:59:37 PM pbarthol. project will result in 2186 sq ft of lot coverage 17.3 . no land use issues anticipated. Electrical load calculations and electrical permits are - �•. 3 required. •-- 1. Establishing Construction Access. 2. Install sediment controls BMPs. _ 3. Stabilize exposed soils. 4 4. Protect slopes from erosion. 5. Protect drain inlets. 6. Control pollutants including but not limited to spills, concrete wash out, exposed 'aggregate processes, concrete grinding and saw cut waste water. 7. Maintain temporary and permanent erosion control BMPS during project. No downspouts shall be connected to sanitary sewer. Use existing driveway opening. Consider applying .for the City Green Infrastructure Rebate , of up to $750.00 towards the materials to install rain Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is,not commenced within 180 days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced,or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct.'All provisions; of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. -01 i w. rate Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder) T:Forms/Building Division/Building Permit BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS— Building Inspections 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION: Footings Stemwall Foundation Drainage/Downspouts Piers Post Holes(Pole Bldgs.) PLUMBING: Under Floor/Slab Rough-in Water Line Meter to Bldg) Gas Line Baric Flow/Water AIR SEAL: Walls Ceiling FRAMING: Joists/Girders/Under Floor Shear Wall/Hold Downs Walls/Roof/Ceiling Drywall Interior Braced Panel Only) T-Bar INSULATION: Slab Wall/Floor/Ceiling MECHANICAL: Heat Pum /Furnace/FAU/Ducts Rough-In Gas Line Wood Stove/Pellet/Chimney Commercial Hood/Ducts MANUFACTURED HOMES: Footing/Slab Blocking&Hold Downs Skirting PLANNING DEPT. Separate Permit#s SEPA: Parkin /Lighting ESA: Landscaping SHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE Inspection Type _ Date Accepted By Electrical 417-4735 Construction - R.W. PW I Engineering 417-4831 Fire 417-4653 Planning 417-4750 Building 417-4815 0Z%'®�. CITY OF PORT ANGELES IM DEPARTMENT OF COMMUNITY& ECONOMIC DEVELOPMENT- BUILDING DIVISION 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Page 2 Application Number . . . . . 16-00000426 Date 4/15/16 - --Application pin number . . . 711956REPORT SALES-TAX - - -=----------------------------------------------------------------------- x. .,.....•. ,:.. ; -Special Notes and Comments on your state excise.tax.fgcrri: garden to control roof and driveway runoff. Also rebates to the City of Port Angeles available for downspout disconnections.Contact Jonathan Boehme at 360 417-4811 (Location Codd 0502) .----------------------------------------------------------------------------- '. t,[ Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 319.75 319.75 .00 .00 Plan Check Total 207.84 207.84 .00 .00 Grand Total 527.59 527.59 .00 .00 _ ... Srl Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized isnot commenced within.180 days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced,or if required inspections have not been requested within 180 dayslfrom the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or.not. The granting of a'permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder) T:Forms/Building Division/Building Permit BUILDING PERMIT INSPECTION RECORD — PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS— Building Inspections 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN CONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION- Footings OUNDATION:Footin s Stemwall Foundation Drainage/Downspouts Piers Post Holes(Pole Bldgs.) PLUMBING: Under Floor/Slab Rough-in Water Line Meter to Bldg) Gas Line Back Flow/Water AIR SEAL: Walls Ceiling FRAMING: Joists/Girders/Under Floor Shear Wall/Hold Downs Walls/Roof/Ceiling Drywall Interior Braced Panel Only) T-Bar INSULATION: Slab Wall/Floor/Ceiling MECHANICAL: Heat Pum /Furnace/FAU/Ducts Rough-In Gas Line Wood Stove/Pellet/Chimney Commercial Hood/Ducts MANUFACTURED HOMES: Footing/Slab Blocking&Hold Downs Skirting PLANNING DEPT. Separate Permit#s SEPA: Parkin /Lighting ESA: Landscaping SHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE Inspection Type _ Date Accepted By Electrical 417-4735 Construction - R.W. PW /Engineering 417-4831 Fire 417-4653 Planning 417-4750 Building 417-4815 THE P�, ; For City Use CITY OF R �jGELES' / r ' r •� r� L 1 Permit# w A s H i N G T o N, U. S. j Date Received: a 321 E 5th Street I ate Approved Q S- II 1,L42 Port Angeles,WA 9836 ! P:360-417-4817 F:360-417-4711 Email:permits@cityofpa.us BUILDING PERMIT APPLICATION Project Address: J6 $ e4 )cGvi -j- Phone: Primary Contact: Email: Name � Phone A LlV , Property Mailing Address Email Owner D I Ga-4&ii S-7L -nut se J, CitState Zip "/ 11(iti- Name VPhone 64&q ulie, Cs�i- (�Cv 46 Address Email e4,7% l Gum Contractor ��� LN I �� e Information City An G State Zi �if?lo Contractor LicenA4 Exp.Date: Legal Description: Zoning: Tax Parcel# Project Value: (materials and labor) L tur, JE A�41s P21 407G 1251 $ -42yo, °O Residential Commercial ❑ Industrial ❑ Public ❑ Permit Demolition ❑ Fire ❑ Repair ❑ Reroof(tear off/lay over) ❑ Classification For the following,fill out both pages of permit application: (check New Construction 9Exterior Remodel ❑ Addition ❑ Tenant Improvement ❑ appropriate) Mechanical ❑ Plumbing ❑ Other ❑ Fire Sprinkler System Proposed Irrigation System Proposed or Proposed Bathrooms Proposed Bedrooms or Existing? Yes 0 No )d Existing? Yes 0 N6)07* N/ In addition to standard hard copy submittals please send a PDF copy of all Stormwater plans and Engineering to www.stormwateroci1yo a.us Project Description GtGTIcG�yG G�` Is project in a Flood Zone: Yes ❑ NoEZ Flood Zone Type: If in a Flood Zone, what is the value of the structure before proposed improvement? $ I have read and completed the application and know it to be true and correct. I am authorized to apply for this permit and understand that it is my responsibility to determine what permits are required and to obtain permits prior to work. I understand that plan review fees are not refundable after review has occurred. I understand that I will forfeit review fees if I withdraw the application before the permit is issued. I understand that if the permit is not picked up/issued within 18o days of submittal,the application will be considered abandoned and the fees will be forfeited. 44AY 19T. Date Print Name Signature Residential Structures Existing Proposed Construction For Office Use Area Descriptions(SQ FT) Floor area Floor area $Value new area Basement First Floor Second Floor Covered Deck/Porch/Entry Deck(over 30"or i" floor) Garage 'ic 3 �_ b226L c� Carport Other(describe) Area Totals Commercial Structures Area Descriptions(SQ FT) Existing Proposed Construction For Office Use Floor area Floor area $Value new area Existing Structure(s) Proposed Addition Tenant Improvement? Other work(describe) Site Area Totals Lot/Site Coverage Calculations Lot Size(sq ft) Lot Coverage(sq ft)foot print of %Lot Coverage(Total lot cov_lot size) Max Bldg Height all structures Z 1,Y1,p sq ft 17, 3 dXo Site Coverage(Sq Ft of all impervious) %of Site Coverage(total site cov_lot size) Mechanical Fixtures Indicate how many of each type of fixture to be installed or relocated as part of this project. Air Handler Size: # Haz/Non-Haz Piping Outlets: Appliance Exhaust Fan # Heater(Suspended,Floor,Recessed wall) # Boiler/Compressor Size: # Heating/Cooling appliance # repair/alteration Evaporative Cooler(attached,not # Pellet Stove/Wood-burning/Gas # portable) Fireplace/Gas Stove/Gas Cook Stove/Misc. Fuel Gas Piping #of Outlets: Ventilation Fan,single duct # Furnace/Heat Pump/ Size: # Ventilation System # Forced Air Unit Plumbing Fixtures Indicate how many of each type of fixture to be installed or relocated Plumbing Traps # Water Heater # Plumbing Vent piping # Medical gas piping #of Outlets: Water Line # Fuel gas piping #of Outlets: Sewer Line # Industrial waste pretreatment interceptor Grease Trap) Size Other(describe): T:\Forms\2015 CED Form Updates\Building&Permitting\BP\Building Permit 20150415.docx OWNER/BULIDER TO CONFIRM DATE : ALL DIMENSIONS, MATERIALS, - - AND CONDITIONS PRIOR TO CONSTRUCTION THESE PLANS ARE COPYRIGHTED BY EYESTONE BUILDING DESIGN REV: AND ARE TO BE USED FOR CONSTRUCTION ONLY BY PERMISSION „- OF EYESTONE BUILDING DESIGN. UNAUTHORIZED USE,SALE, 3/24/2016 - - -- ALTERATION,OR REPRODUCTION OF THESE PLANS FOR ANY - ❑ - PROJECT OTHER THAN THAT FOR WHICH THEY WERE ORIGINALLY INTENDED IS A VIOLATION OF FERDERAL COPYRIGHT LAW. - EXTERIOR NOTES: .� 0 LEFT 1 /b1)ATTIC VENT: RIDGEVENT & EAVE VENT 2) ROOF PITCH: 6:12 3) ROOFING: COMP051TION SHINGLE t6 t� 4) FASGIA& BARGE: 5/4x8 PRIMED 5PRUGE < 00 5) OVERHANG: EAVE: 16" o 6)SOFFIT: OPEN OL '7)SIDING: FIBERGEMENT LAP . 5)CORNERBOAR05: 5/4x4 PRIMED 5PRUGE Q v 9)WINDOW TRIM: 5/4x4 PRIMED 5PRUGE Z U O FRONT 1 /4 = 1 ' o o tl J - Z REAR = w O ( M GENERAL NOTES: o n J Lu .(� 1)ALL GON5TRUCTION TO CONFORM TO 2012 IRG. m z Lu cn 2)ALL MATERIALS & EQUIPMENT TO BE INSTALLED PER ......- - -- - - Z MAN. 5PEG'5. M - - O o w .n oji 3)OCCUPANCY: RESIDENTIAL w '1 , z 4)GON5TRUCTION: NON-RATED __ — _.._ _........ 5) DESIGN CRITERIA: - _— - _ _- 0 o p Ln 5E15MIG ZONE: 02 . ----- -- -- 1- 501L BEARING: 1500 P5F --__--- - -.- - - _ _ - -- (D Q tY WIND LOAD: 100 MPH GUST - -- - - _ -- --- -- 1 t a (� 0 0 — — EXP05URE: G - _ _ c� a ELEVATION: <625' ------ -- ROOF LOAD: 15 DEAD; 25 5NOW 6)ONE 5TORY F A � l 18' 18' DATE : - - - - - - - - - - - - - - - - - - - - r - - - - - - - - - - -- - - - - - - - - - - - -� 3-23-16 - - - - - - - - - - - - - - - 6 X 22 CONCRETE 5TEMWALL I I - I I I REV W/#4 BAR @ 48" O.G. VERT. ' & (1) HOR. TOP BAR I I I I I 3/24/2016 & 1/2 X 10 A.B. W/3x3x1/4 WASHER @ 48" O.G. I I I I I 4" CONCRETE SLAB I I I I I ori N OYER 2" SAND I I a' 6 MIL. POLY. VAPOR BARRIER I - - — -- — - — I 6 COMPACT FILL A5 NEEDED I I I PRE-MAN. ENG.TRU55E5 Q 24"O.G. I r f1 UND15TURBE0 NATIVE 561L I I I I V / o < �y o W� i z m I I ^ I I m m d- I GARAGE r w I I m � 31'-0" x '-o" ^ I o Gross Section'I I Ii Q� � Gross Section �- a o v I I 2"SLOPE i i I r- - - - - -I— � I Q O z d- I Ln o Lu o o I I I 1 I I W z Lu M I I I I I I I I o Q Ln 00 12 X 6 CONCRETE FOOTING I I I I `• Lu I Lu Lu — N W/(2)#4 BAR CONT. I I I I ,-I Q c L - -- - - - - - - - - - - -- - � I o 4 X 12 DF#2 HEADER N FLu - - - -- - - - - - - - - - - -- - - - I I - - - - -I- - - - - 11 00 = c L - - - - - - - - = - 4� r1f/�- - J } tD t' 0 0 Y-4 1/2" 3'-4 1/2" �� c7�Fi y a N a ` — 111-311 � o 18' 18' FOUNDATION PLAN 1 /4" = 1 ' MAIN FLOOR PLAN 1 /411 = 11 A- DATE : 3-23-16 v 0 14'4 3I5" � FILE REV: 3/24/2016 CITY OF PORT ANG17,1ES-Construction Plats O The Issuance of this permit based upon these plans n` specifications and other data shall not prevent the VJ building official from thereafter requiring the (n correction of errors in said plans,specifications and •� �+ other data. or from presenting building operations L EXI5TIN6 HOUSE being carried on thereunder%k hen in violation of all �O - ` •encE -gl 5 6. codes and ordinances of this jurisdiction. N N ALL V4'URK SU131EC7' I U FIELD APPROVAL L N Date � b �1�'!/,,,,By JTC �3 v �jN a0 a - , ���� 21 0 OL0 CONTINUOUS RIDGEVENT COMP051TION SHINGLE ROOFING 15#FELT z 1/16"05B 5HEATHING H O PRE-MAN.TRU55E5 Q 24"O.G. U -+ 6:12 PITCH R-35 IN5ULATION � Q 5/8"GWB 0 U NAIL ROOF 5HEATHING J W/Sd Q b"O.G.TO a O 2X BLOCKING BETWEEN TRU55E5 OR TO 2X FA56IA 5/4x8 PRIMED SPRUCE FA501A&BARGE z "K"STYLE CONTINUOUS METAL 6UTTER5 U 16"OVERHANG w o jt 5OFF1T:OPEN 5/6"RUFF-TEX I/ 2x4 BIRD-BLOCK VENTING (D o to jLU0) 6 0 PLOT PLAN 1 " = 20 1:01/21, Z: LU M j— 1/2"GWB LU R-21 IN5ULATION z It I O 2xb 5TUD5 Q 24"O.G. 1 O m "1/16"058 5HEATHING —� FSl� � .� �• 4"CONCRETE 5LAB BREATHABLE HOU5E WRAP � v OVER 2"SAND FIBERGEMENT LAP 51DING LU z 6 MIL. POLY.VAPOR BARRIER � � COMPACT FILL A5 NEEDED -1 c W UND15TURBED NATIVE 501L r- ; b X 22 CONCRETE 5TEMALL NO O V) W/#4 BAR cQ 48"O.G.VERT. & LU c (1)HOR.TOP BAR = J �12 X 6 CONCRETE FOOTING W/(2)#4 BAR CONT. � vi Q 0 0 t1 N d O U OR055 5EOTION 1 /411 = 11 A - 3