Loading...
HomeMy WebLinkAbout1117 Dunker Drive Address: 1117 Dunker Drive PREPARED 7/11/16, 10:18:29 INSPECTION TICKET PAGE 1 CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 7/11/16 ----------------------------- ADDRESS . : 1117 DUNKER DR SUBDIV: ' CONTRACTOR ACE MICHAELS INC PHONE (360) 460-6172 OWNER ACE MICHAELS INC PHONE (360) 460-6172 PARCEL 06-30-01-8-3-0170-0000- APPL NUMBER: 16-00000081 RES NEW SFR ------------------------------------------------------------------------------------------------ PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS -------------------------------------- BL1 01 2/03/16 JLL BLDG FOUNDATION FOOTING 2/03/16 , AP February 3, 2016 9:49:23 AM jlierly. Mike Caudill February 3, 2016 4:27:56 PM jlierly. BL2 01 2/10/16 JLL BLDG FOUNDATION STEM WALL 2/10/16 AP February 10, 2016 9:23:00 AM jlierly. AM February 10, 2016 3:54:18 PM jlierly. BFF 01 3/25/16 JLL BLDG FLOOR FRAMING - 3/25/16 AP March 25, 2016 8:48:48 AM jlierly. Mike 460-6172 March 25, 2016 4:07:11 PM jlierly. BEXS 01 4/12/16 - JLL BLDG EXTERIOR SHEETING .4/12/16 AP April 12, 2016 9:37:27 AM jlierly. Mike April 12, 2016 3:54:04 PM jlierly. BAIR 01 5/04/16 PB BLDG AIR SEAL 5/06/16 AP May 4, 2016 9:57:00 AM pbarthol. May 6, 2016 12:48:13 PM pbarthol. BL3 01 5/04/16 PB BLDG FRAMING 5/06/16 AP May 4, 2016 9:56:44 AM pbarthol. Mike 460-6172 May 6, 2016 12:48:13 PM pbarthol. BEXS 02 5/20/16 JLL BLDG EXTERIOR SHEETING 5/20/16 AP May 20, 2016 9:05:57 AM jlierly. g2 May 20, 2016 4:37:54 PM jlierly. BL99 01 7/11/16 BLDG FINAL July 11, 2016 10:14:11 AM jlierly. ------------------------------------------------------------------ PERMIT: ME 00 MEC NI PERMIT REQUESTED INSP DESCRIPTION - TYP/SQ COMPLETED RESULT RESULTS/COMMENTS --------------------- ----------------------------------—----------------------------- ME99 01 7/11/16 MECHANICAL FINAL July 11, 2016 10:14:32 AM jlierly. Mike 460-6172 --------------------------------------------------------------- --------------------------------- PERMIT: PL 00 PLUMBING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - ------------------------ ------ PL2 01 4/21/16 JLL PLUMBING ROUGH-IN 4/25/16 AP April 21, 2016 8:33:15 AM jlierly. Mike 461-6172 April 25, 2016 4:49:51 PM jlierly. PL2 02 5/20/16 JLL PLUMBING ROUGH-IN ----------------------------------- CONTINUED ONTO NEXT PAGE ----------------------------------- PREPARED 7/11/16, 10:18:29 INSPECTION TICKET PAGE 2 CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 7/11/16 -----------—-----------—---'-—---------- ---------- ADDRESS ----ADDRESS 1117 DUNKER DR SUBDIV: CONTRACTOR ACE MICHAELS INC PHONE (360) 460-6172 OWNER ACE MICHAELS INC PHONE (360) 460-6172 - PARCEL 06-30-01-8-3-0170-0000- APPL NUMBER: 16-00000081 RES NEW SFR ------------------------------------------------------------------------------------------------ REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS --- -----------------------Y---------------------------- -------------- 5/20/16 AP May jlierly. 20, 2016 9:05:28 AM Mike May 20, 2016 4:37:54 PM jlierly. - PL99 01 7/11/16 L PLUMBING FINAL 0 July 11, 2016 10:15:02 AM jlierly. --------------------- ------------- COMMENTS AND NOTES --------- s PREPARED 4/21/16, 8:39:45 INSPECTION TICKET PAGE 5 CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 4/21/16 —-------------- ----------—---—-- ADDRESS . : 1117 DUNKER DR SUBDIV: CONTRACTOR ACE MICHAELS INC PHONE (360) 460-6172 OWNER ACE MICHAELS INC PHONE (360) 460-6172 PARCEL 06-30-01-8-3-0170-0000- APPL NUMBER: 16-00000081 RES NEW SFR ------------------------------------------------------------------------------------------------ PERMIT: PL 00 PLUMBING PERMIT REQUESTED, INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS -------—---— - ---—------------—--------------- -------------—------ -- PL2 01 4/21/16 JL PLUMBING ROUGH-IN April 21, 2016 8:33:15 AM jlierly. Mike 461-6172 --------------------- ----------------- ---- ------ COMMENTS AND NOTES -------------------------------------- ��.. CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT- BUILDING DIVISION 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Application Number . . . . . 16-00000081 Date 1/29/16 Application pin number . . . 797439 Property Address . . . . . . 1117 DUNKER DR ASSESSOR PARCEL NUMBER: 06-30-01-8-3-0170-0000- REPORT SALES TAX Application type description RES NEW SFR on your state excise tax form Subdivision Name . . . . . . Property Use . . . . . . . . to the City of Port Angeles Property Zoning . . . . . . . RS9 RESDNTL SINGLE FAMILY Application valuation . . . . 138650 (Location Code 0502) ----------------------------------------------------------------------------- - Application desc 1882 SF SINGLE STORY 3BED 2BATH SFR ---------------------------------------------------------------------------- _ Owner Contractor ------------------- -- ------------------------ ACE MICHAELS INC ACE MICHAELS.INC 1329 W 10TH ST 1329 W. 10TH ST. �) PORT ANGELES WA 98363 PORT ANGELES WA 98363 (360) 460-6172 (360) 460-6172 --------------------------------=------------------------------------------- Permit . . . . . . BUILDING PERMIT -RESIDENTIAL Additional desc 1882 SF SINGLE STORY SFR Permit Fee . . . . 1238.65 Plan Check Fee .00 Issue Date . . . . 1/29/16 Valuation . . . . 138650 Expiration Date 7/27/1.6 Qty Unit Charge Per Extension BASE FEE 1020.25 39.00 5.6000 THOU BL-100,001-500K (5.60 PER K) 218.40 ---------------------------------------------------------------------------- �. Permit . . . . . . MECHANICAL PERMIT Additional desc . . SFR MECHANICAL Permit Fee . . . . 171.20 Plan Check Fee .00 ` Issue Date . . . . 1/29/16 Valuation . . . . 0 Expiration Date . . 7/27/16 J Qty Unit Charge Per Extension BASE FEE 50.00 S 1.00 14.8000 EA ME-FURN/HP/FAU < OR = 5 TON 14.80 S 3.00 7.2500 EA . ME-VENT FAN (SINGLE DUCT) 21.75 1.00 10.6500 EA ME-HOOD/DUCT-MECH_ EXHAUST 10.65 5.00 14.8000 EA ME-HEATER(SUSP/WALL/FLOOR-MTD) 74.00 ------ Permit . . . . . PLUMBING PERMIT Additional desc SFR PLUMBING Permit Fee . . . . 163.00 Plan Check Fee .00 Issue Date . . . . 1/29/16 Valuation . . . . 0 Expiration Date 7/27/16 Qty Unit Charge Per Extension BASE FEE 50.00 8.00 7.0000 EA PL-PLUMBING TRAP 56.00 1.00 7.0000 EA PL-WATER LINE 7.00 4.00 7.OQ00 EA PL-DRAIN VENT PIPING 28.00 Separate Permits are required forelectrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within.180 days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder) T:Forms/Building Division/Building Permit BUILDING PERMIT INSPECTION RECORD — PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS— Building Inspections 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION: Footings Stemwall Foundation Drainage/Downspouts Piers Post Holes(Pole Bldgs.) PLUMBING: Under Floor/Slab Rough-In Water Line Meter to Bldg) Gas Line Back Flow/Water AIR SEAL: Walls Ceiling u FRAMING: Joists/Girders/Under Floor Shear Wall/Hold Downs + Walls/Roof/Ceiling Drywall Interior Braced Panel Only) T-Bar INSULATION: Slab Wall/Floor/Ceiling MECHANICAL: Heat Pum /Furnace/FAU/Ducts Rough-in Gas Line Wood Stove I Pellet/Chimney Commercial Hood/Ducts MANUFACTURED HOMES: Footing/Slab Blocking&Hold Downs Skirting PLANNING DEPT. Separate Permit#s SEPA: Parkin /Lighting ESA: Landscaping SHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE Inspection Type _ Date Accepted By Electrical 417-4735 Construction -R.W. PW I Engineering 417-4831 Fire 417-4653 Planning 417-4750 Building 417-4815 CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT- BUILDING DIVISION o� 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Page 2 Application Number . . . . . 16-00000081 Date 1/29/16 Application pin number 797439 REPORT SALES TAX Qty Unit Charge Per Extension on our state excise tax form 1.00 15.0000 EA PL-SEWER LINE 15.00 Y 1.00 7.0000 EA PL-WATER HEATER 7.00 to the City of Port Angeles --------------------------------------------------------------- Special Notes and Comments (Location Code 0502) January 20, 2016 9:26:28 AM pbarthol. Plan check fee paid on permit 15-1003. Same plans are being used for 1008 Dunker Dr, 1117 Dunker Dr, and 1123 Dunker Dr. Site copy of plans will need to be available at all three housed during inspections. January 21, 2016 8:28:42 AM rbecker. The squares asking if you was going to install a fire, or irrigation system did not get marked. So if you are installing either one of these, contact me about installing a backflow assembly. If you have any questions call me at 360-417-4886, Fax:360-452-4972, or E-mail:rbecker@cityofpa.us Address numbers shall be plainly visible from the street. Address numbers shall be a minimum of six inches high and be of contrasting color from the background. All homes in new subdivisions that are outside of the Fire Department four-minute response area shall be equipped with residential fire sprinkler systems that comply with the International Fire Code (IFC) and National Fire Protection Association (NFPA) . Call for cover inspection for all sprinkler installations. A full acceptance test will be required for the fire sprinkler system. ` Owner is responsible for ongoing fire sprinkler system inspection and testing per the current addition of NFPA 25. Electrical load calculations and electrical permits are required. 1. Establishing Construction Access. 2. Install sediment controls BMPs. 3. Stabilize exposed soils. 4. Protect slopes from erosion. 5. Protect drain inlets. G. Control pollutants including but not limited to spills, concrete wash out, exposed aggregate processes, concrete grinding and saw cut waste water. 7. Maintain temporary and permanent erosion control BMPS during project. All disturbed area's on site not covered by new improvements should meet the attached soil quality and depth standard. Consider applying for the City Green Infrastructure Rebate of up to $750.00 towards the materials to install rain garden to control roof and driveway runoff. Also rebates available for downspout disconnections.Contact Jonathan Separate Permits are required forelectrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinancesovernin g g this type of work will be complied with whether specified herein or not. The granting of a permit does not g g presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder) T:Forms/Building Division/Building Permit BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS— Building Inspections 4174815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION: Footings Stemwall Foundation Drainage/Downspouts Piers Post Holes(Pole Bldgs.) PLUMBING: Under Floor/Slab Rou h-In Water Line Meter to Bldg) Gas Line Back Flow/Water AIR SEAL: Walls Ceiling ` FRAMING: Joists/Girders/Under Floor Shear Wall/Hold Downs Walls/Roof/Ceiling Drywall Interior Braced Panel Only) T-Bar INSULATION: Slab Wall/Floor/Ceiling MECHANICAL: Heat Pum /Furnace/FAU/Ducts Rough-In Gas Line Wood Stove/Pellet/Chimney Commercial Hood/Ducts MANUFACTURED HOMES: Footing/Slab Blocking&Hold Downs Skirting PLANNING DEPT. Separate Permit#s SEPA: Parkin /Lighting ESA: Landscaping SHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE Inspection Type _ Date Accepted By Electrical 417-4735 Construction - R.W. PW I Engineering 417-4831 Fire 417-4653 Planning 417-4750 Building 417-4815 . CITY OF PORT ANGELES ►�i� DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT- BUILDING DIVISION •t. r� 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Page 3 Application Number . . . . . 16-00000081 Date 1/29/16 Application pin number . . . 797439 ---------------------------------------------------------------------------- REPORT SALES TAX Special Notes and Comments Boehme .at 360 417-4811 on your state excise tax form Sanitary sewer connection inspection is required by to the City of Port Angeles Public Works prior to back fill of ditch. 24 hour advance notice is required. Public Works Inspection request line (Location Code 0502) 417-4831 Trench safety per applicable laws. Temp erosion control and surface restoration responsibility of applicant—Contact City inspector prior to start of work @ 360 417-4831. No attachment to sanitary sewer of stormwater roof leaders, foundation drains, yard drains, or any other CSO contribution is allowed. The contractor making the connection to an existing water meter is responsible to adjust water meter depth so that there is a minimum of 4 to 6 inches of clearance between the bottom of the meter box lid and the top of the meter at finish grade. : Construct driveway to City Standards. Concrete with exposed aggregate or other non-standard finishes(including colors or dyes)are not allowed.in the City road right of way. Broom finish only. An inspection by Public Works Engineering is required prior to pouring concrete. Public Works inspection request line 417-4831 ---------------------- ----------------------------------------------------- Other Fees . . . . . . . . . CITY DRA 47.32 DRA FEES PLUS INTEREST 1409.76 RES UNDERGRND SERVICE FEE 770.00 SEWER SYSTEM DELV CHARGE 2260.00 STATE SURCHARGE 4.50 PW WATER SYSTEM USE FEE 2260.00 ` ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 1572.85 1572.85 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 6751.58 6751.58 .00 .00 Grand Total 8324.43 8324.43 .00 .00 Separate Permits are required forelectrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder) T:Forms/Building Division/Building Permit • BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS— Building Inspections 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION: Footings Stemwall Foundation Drainage/Downspouts Piers Post Holes(Pole Bldgs.) PLUMBING: Under Floor/Slab Rough-in Water Line Meter to Bldg) Gas Line Back Flow/Water AIR SEAL: Walls Ceiling FRAMING: Joists/Girders/Under Floor Shear Wall/Hold Downs Walls/Roof/Ceiling Drywall Interior Braced Panel Only) T-Bar INSULATION: Slab Wall/Floor/Ceiling MECHANICAL: Heat Pum /Furnace/FAU/Ducts Rough-in Gas Line Wood Stove/Pellet/Chimney Commercial Hood/Ducts MANUFACTURED HOMES: Footing/Slab Blocking&Hold Downs Skirting PLANNING DEPT. Separate Permit#s SEPA: Parkin /Lighting ESA: Landscaping SHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE Inspection Type _ Date Accepted By Electrical 417-4735 Construction - R.W. PW I Engineering 417-4831 Fire 417-4653 Planning 417-4750 • Building 417-4815 THE t For City Use CITY OFC?RT NGELES. ] Permit# W A S H I N G T O N, U. S. Date Received: 321 E 51h Street Date Approved Port Angeles,WA 9836 P:360-417-4817 F:360-417-4711 - Email:permits0cityofpa.us BUILDING PERMIT APPLICATION - Project Address: I I t Phone: 3 (O Prima Contact: 1�\� �1���) Email: Phone Na a &"L At, c/ Property Mailin Address Email Owner _ . City �n �� r \ State Name vx �0 5 / ( Phone Contractor Nµ` Address Email -Informati'O City state zip Contractor License# Exp.Date: Legal Description: Zoning: Tax Parcel # Project Value: (materials and labor) $ 11 S--ZD.. _ Residential '71 Commercial ❑ Industrial ❑ Public ❑ Permit Demolition ❑ Fire ❑ Repair ❑ Reroof(tear off/lay over) ❑ Classification For the following,fill out both pages of permit application: _ (check New ConstructionExterior Remodel 11Addition 1:1Tenant Improvement 11appropriate) Mechanical ❑ Plumbing ❑ Other ❑ Fire Sprinkler System Proposed Irrigation System Proposed orProposed Bathrooms Proposed Bedrooms or Existing? Yes 0 No 0 Existing? Yes 0 No 0 `- 3 In addition to standard hard copy submittals please send a PDF copy of all Stormwater plans and Engineering to w%vw.stormwaterRcityofpa.us - Project Description v 4, A i c K e,� Is project in a Flood Zone: Yes 0 No❑ Flood Zone Type: If in a Flood Zone,what is the value of the structure before proposed improvement? $ I have read and completed the application and know it to be true and correct. I am authorized to apply for this permit and understand that it is my responsibility to determine what permits are required and to obtain permits prior to work. I understand that plan review fees are not refundable after review has occurred. I understand that I will forfeit review fees if I withdraw the application before the permit is issued. I understand that if the permit is not picked up/issued within i8o days of submittal,the application will be considered abandoned and the fees will be forfeited. Date H V I �o Print Name ��)4c (—Nb L—L Signature / , Residential Structures Existing Proposed Construction For Office Use Area Descriptions(SQ FT) Floor area Floor area. } . $,Value new area Basement First Floor Second Floor Covered Deck/Porch/Entry Deck(over 30"or 2" floor) Garage 400 144 Carport Other(describe) Area Totals _ .... ......:.... a ) 3 e(05 D Commercial Structures Area Descriptions(SQ.FT) Existing . Proposed Construction For Office Use Floor area Floor area $Value new area Existing Structure(s) Proposed Addition Tenant Improvement? Other work(describe) Site Area Totals Lot/Site Coverage Calculations Lot Size(sqLot Coverage(sq ft)foot print of %Lot Covera a(Total lot cov_lot size) Max Bldg Height �jl- ft)n all structures $p� s ft 4Z 6 Z Site Coverage(Sq Ft,of all impervious) %of Site Covera atotal site cov-lot size) Mechanical Fixtures Indicate how.many of each type of fixture to be installed or relocated as part of this project. Air Handler Size: # Haz/Non-Haz Piping Outlets: Appliance Exhaust Fan - . # ' Heater(Suspended,Floor,Recessed wall) # Boiler/Compressor Size: # Heating/Cooling appliance # repair/alteration Evaporative Cooler(attached,not # Pellet Stove/Wood-burning/Gas # portable) Fireplace/Gas Stove/Gas Cook Stove/Misc. Fuel Gas Piping #of Outlets: Ventilation Fan,single duct # 3 Furnace/Heat Pump/ R-� ize: # Ventilation System # Forced Air Unit J -'s Plumbing Fixtures Indicate how many of each type of fixture to be installed or relocated Plumbing Traps # Water Heater # Plumbing Vent piping # Medical gas piping #of Outlets: Water Line # Fuel gas piping #of Outlets: Sewer Line # I Industrial waste pretreatment interceptor Grease Trap) Size Other(describe): T:\Forms\2015 CED Form Updates\Building&Permitting\BP\Building Permit 20150415.docx �0 �- e7 CITY OF PORT ANGELES-Co tion Plans The issuance of this permit based u n these plans specifications and other data shall a t prevent the building official from thereafter equiring the 1 11 correction of em in said plans,spa fications and other data,or n preventing build' g operations being carried on ereunder when in iolatioa of all C nalces of this jurisdi ' ALL PECT TO FIELD PROVAL Daft / o By J �Fc� CA- / zee f 1014 F 104 s" � w.� xf •" � j � W 2332 2311. 2307.. 2322 ._.._...._-._.._. _ , L-7- 14 I'd II O. m -- ai M— ✓ll 41 7i v� b � J � ,I y 4 -91 -ol rn �o o tj �.., .. ; :, 1.� � ,/?/"iO"IS�Ste!' - . . � � � `n _o °.I •. D -`� + �x �sg17 D Prescriptive Energy Code Compliance for All Climate Zones in Washington Project Information Contact Information / � 7AA4 1 This project will use the requirements of the Prescriptive Path below and incorporate the the minimum values listed. In addition, based on the size of the structure,the appropriate number of additional credits are checked as chosen by the permit applicant. 4Authorized Representative " C Date All Climate Zones R-Value' U-Factor' Fenestration U-Factorb n/a 0.30 Skylight U-Factor n/a 0.50 Glazed Fenestration SHG Cb,e n/a n/a Ceiling 44 0.026 Wood Frame Wall9,k,l 21 int 0.056 Mass Wall R-Value' 21/21h 0.056 Floor 309 0.029 Below Grade Wall`k 10/15/21 int+TB 0.042 Slab R-Value&Depth 10,2 ft n/a 'Table R402.1.1 and Table R402.1.3 Footnotes included on Page 2. Each dwelling unit in one and two-family dwellings and townhouses, as defined in Section 101.2 of the International Residential Code shall comply with sufficient options from Table R406.2 so as to achieve the following minimum number of credits: 91. Small Dwelling Unit: 0.5 points Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration area. Additions to existing building that are less than 750 square feet of heated floor area. ❑ 2. Medium Dwelling Unit: 1.5 points All dwelling units that are not included in#1 or#3, including additions over 750 square feet. ❑ 3. Large Dwelling Unit: 2.5 points Dwelling units exceeding 5000 square feet of conditioned floor area. Table R406.2 Summary Option Description Credit(s) 1 a Efficient Building Envelope 1 a 0.5 ❑ 1 b Efficient Building Envelope 1 b 1.0 ❑ 1c Efficient Building Envelope 1c 2.0 ❑ 2a Air Leakage Control and Efficient Ventilation 2a 0.5 ❑ 2b Air Leakage Control and Efficient Ventilation 2b 1.0 ❑ 2c Air Leakage Control and Efficient Ventilation 2c 1.5 ❑ 3a High Efficiency HVAC 3a 0.5 p. 3b High Efficiency HVAC 3b 1.0 ❑ 3c High Efficiency HVAC 3c 2.0 ❑ 3d High Efficiency HVAC 3d 1.0 ❑ 4 High Efficiency HVAC Distribution System 1.0 ❑ 5a Efficient Water Heating 0.5 ❑ 5b Efficient Water Heating 1.5 ❑ 6 1 Renewable Electric Energy 0.5 '1200 kwh 0.0 Total Credits 0.00 *Please refer to Table R406.2 for complete option descriptions http://www.energy.wsu.edu/Documents/2012%2ORes`/`2OEnergy.pd Table R402.1.1 Footnotes For SI: 1 foot.=304.8 mm, ci.=continuous insulation, int.= intermediate framing. a R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity which is less than the label or design thickness of the insulation,the compressed R-value of the insulation from Appendix Table A101.4 shall not be less than the R-value specified in the table. b The fenestration U-factor column excludes skylights.The SHGC column applies to all glazed fenestration. Exception:Skylights may be excluded from glazed fenestration SHGC requirements in Climate Zones 1 through 3 where the SHGC for such skylights does not exceed 0.30. "10/15/21.+TB" means R-10 continuous insulation on the exterior of the wall,or R-15 on the continuous insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the basement wall at the interior of the basement wall. "10/15/21.+TB".shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. "10/13" means R-10 continuous insulation on the interior or exterior of the home or R- 13 cavity insulation at the interior of the basement wall. "TB" means thermal break between floor slab and basement wall. d R-10 continuous insulation is required under heated slab on grade floors.See R402.2.9.1. e There are no SHGC requirements in the Marine Zone. f Basement wall insulation is not required in warm-humid locations as defined by Figure R301.1 and Table R301.1. g Reserved. h First value is.cavity insulation,second is continuous insulation or insulated siding,so"13.+5" means R-13 cavity insulation plus R-5 continuous insulation or insulated siding. If structural sheathing covers 40 percent or less of the exterior, continuous insulation R{value shall be permitted to be reduced by no more than R-3 + in the locations where structural sheathing is used to maintain a consistent total sheathing thickness. 'The second R-value applies when more than half the insulation is on the interior of the mass wall. ' ' For single rafter-or joist-vaulted ceilings,theinsulation may be reduced to R-38. k Int. (intermediate framing)denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation. 'Log and solid timber walls with a minimum average thickness of 3.5 inches are exempt from this insulation requirement. Table R402.1.3 Footnote a Nonfenestration U-factors shall be obtained from measurement,calculation or an approved source or as specified in Section R402.1.3.