HomeMy WebLinkAbout1119 E. Park Avenue Address: 1119 E Park Avenue j ( 11 c - tGI �- /�--f& PREPARED 5/01/15, 8:33:16 INSPECTION TICKET PAGE 2 ' CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 5/Oi/15 ------------------------------------------------------------------------------ ADDRESS 1119 E PARK AVE SUBDIV: CONTRACTOR KED/TER CONSTRUCTION INC PHONE (360) 460-0139 OWNER TIKKA SAMUEL J PHONE PARCEL 06-30-11-5-1-0690-0000- APPL NUMBER: 14-00000774 RES REPAIR ------------------------------------------------------------------------------------------------ PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT -RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ BLFW O1 8/05/14 JLL BLDG FOUND FTG/STEM WALL 8/05/14 AP August 5, 2014 12:43:27 PM permits. August 5, 2014 4:02:08 PM jlierly. BL9 01 10/07/14 JLL BLDG SHEARWALL 10/07/14 DA October G, 2014 1:44:03 PM permits. October 7, 2014 4:10:21 PM jlierly. Exterior sheathing is ok except in the areas of the north facing wall that is cantilevered ( this was not on the plans and will need to be examined by the Architect) and the open covered deck that will be enclosed. provide details for shear and uplift in the roof and new wall area/JLL BAIR O1 11/18/14 JLL BLDG AIR SEAL 11/18/14 AP November 18, 2014 9:29:26 AM pbarthol. Mike 460-0731 November 18, 2014 4:35:29 PM jlierly. BL3 01 11/18/14 JLL BLDG FRAMING 11/18/14 AP November 18, 2014 9:28:55 AM pbarthol. Mike 460-0731 November 18, 2014 4:35:43 PM jlierly. BLI O1 11/24/14 JLL BLDG INSULATION 11/24/14 AP November 21, 2014 12:32:21 PM jlierly. November 24, 2014 4:30:37 PM jlierly. BL9 02 11/24/14 JLL BLDG SHEARWALL 11/24/14 AP November 24, 2014 10:10:59 AM jlierly. November 24, 2014 4:30:37 PM jlierly. BLDR O1 12/05/14 JLL BLDG DRYWALL IBWP 12/05/14 AP December 5, 2014 8:50:29 AM pbarthol. Rick 460-0139 December 5, 2014 4:04:15 PM jlierly. BL99 01 5/01/15 L BLDG FINAL May 1, 2015 8:35:45 AM jlierly. rick 460-0139 1 -------------------------------------- COMMENTS AND NOTES -------------------------------------- CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY& ECONOMIC DEVELOPMENT- BUILDING DIVISION 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Application Number . . . . . 14-00000774 Date 8/05/14 Application pin number . . . 541012 Property Address . . . . . . 1119 E PARK AVE ASSESSOR PARCEL NUMBER: 06-30-11-5-1-0690-0000- REPORT SALES ALES TAX Application type description RES REPAIR Subdivision Name . . . . . . on your state excise tax form Property Use . . . . . . . . to the City of Port Angeles Property Zoning . . . . . . . UNKNOWN (Location Code 0502) Application valuation . . . . 462839 ---------------------------------------------------------------------------- Application desc pepair fire damage M` ---------------------------------------------------------------------------- �3 Owner - Contractor ------ ------------------------ TIKKA SAMUEL J KED/TER CONSTRUCTION INC 1119 E PARK AVE 4304 OLD MILL RD PORT ANGELES WA 983622740 PORT ANGELES WA 98362 (3 60) 460-0139 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT -RESIDENTIAL Additional desc . . REPAIR FIRE DAMAGE Permit Fee . . . . 3053.05 Plan Check Fee 1984.48 Issue Date . . . . 8/05/14 Valuation . . . . 462839 Expiration Date . . 2/01/15 M Qty Unit Charge Per Extension BASE FEE 1020.25 363.00 5.6000 THOU BL-100,001-500K (5.60 PER K) 2032.80 ---------------------------------------------------------------------------- Special Notes and Comments July 9, 2014 8:47:36 AM sroberds. Work is fire damage and interior remodel in the RMD zone. No additional lot cov. Lot cov is 9$. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE SURCHARGE 4.50 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 3053.05 3053.05 .00 .00 Plan Check Total 1984.48 1984.48 .00 .00 Other Fee Total 4.50 4.50 .00 .00 Grand Total 5042.03 5042.03 .00 .00 ( V V' Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes P null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any s law re ulating construction or the performance of construction Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder) T:Forms/Building Division/Building Permit BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS— Building Inspections 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION: Footings Stemwall Foundation Drainage/Downspouts Piers Post Holes(Pole Bldgs.) PLUMBING: Under Floor/Slab Rough-in Water Line Meter to Bldg) Gas Line Back Flow/Water FINAL Date Accepted b AIR SEAL: Walls Ceiling FRAMING: Joists/Girders/Under Floor Shear Wall/Hold Downs Walls/Roof/Ceiling Drywall Interior Braced Panel Only) T-Bar INSULATION: Slab Wall/Floor/Ceiling MECHANICAL: Heat Pum /Furnace/FAU/Ducts Rough-in Gas Line Wood Stove/Pellet/Chimney Commercial Hood/Ducts FINAL Date Accepted b MANUFACTURED HOMES: Footing/Slab Blocking&Hold Downs Skirting PLANNING DEPT. Separate Permit#s SEPA: Parkin /Lighting ESA: Landscaping SHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE Inspection Type Date Accepted By Electrical 417-4735 Construction-R.W. PW I Engineering 417-4831 Fire 417-4653 Planning 417-4750 Building 417-4815 T:Forms/Building Division/Building Permit THE •. For City Use 41" 1 11'_ CITY OF10 Permit# M W A S H I N G T O N, U . S. D to Received: ZV - 321 E 51h Street a Approved Port Angeles,WA 9836 P:360-417-4817 F:360-417-4711 Email:permits@citvofpa.us BUILDING PERMIT APPLICATION Project Address: Phone: ® e�l,5 Primaq Contact: Email: Name Phone Q Property Mailing Addr ss Email Owner City State'0 � r/ zipi� Name Phone ti q Contractor Address / Email Information Ci ty OAT �6���f State Zip Z� Contractor License# "A Exp.Date: Legal Description: Zoning: Tax Parcel# Project Value: (materials and labor) � D $ Residential,A Commercial ❑ Industrial ❑ Public ❑ Permit Demolition ❑ Fire JM Repair J9 Reroof(tear off/lay over) ❑ Classification For the following,fill out both pa e s of permit application: (check New Construction ❑ Exterior Remodel ❑ Addition ❑ Tenant Improvement ❑ appropriate) Mechanical ❑ Plumbing ❑ Other ❑ Will a fire sprinkler system be installed Irrigation System? Proposed Bathrooms Proposed Bedrooms or modified? Yes ❑ No ❑ Yes ❑ No ❑ Project Description �Z' ;A 0 el-I 61 AJa— 4 4, Is project in a Flood Zone: Yes ❑ No% Flood Zone ype: If in a Flood Zone, what is the value of the structure before proposed improvement? $ I have read and completed the application and know it to be true and correct. I am authorized to apply for this permit and understand that it is my responsibility to determine what permits are required and to obtain permits prior to work. I understand that plan review fees are not refundable after review has occurred. I understand that I will forfeit review fees if I withdraw the application before the permit is issued. I understand that if the permit is not picked up/issued within i8o days of submittal,the application will be considered abandoned and the fees will be forfeited. �. ,F 71® e� Date Print Name Signature 1� Residential Structures For Office Use Area Description(SQ FT) Existing Proposed ss value Basement First Floor Second Floor Covered Deck/Porch/Entry Deck(over 30"or 2'dfloor) Garage Carport Other(describe) Area Totals Commercial Structures Proposed For Office Use Area Descriptions(SQ FT) Existing Proposed ss Value Existing Structure (s) Proposed Addition Tenant Improvement? Other work(describe) Site Area Totals Lot/Site Coverage Calculations Lot Size(sq ft) Lot Covera ( ft) _ '� %Lot Coverage(Total lot coverage_lot size) Site Coverage (Sq Ft of all impervious) %of Site Coverage(total site coverage_lot size) Mechanical Fixtures Indicate how many of each type of fixture to be installed or relocated as part of this project. Air Handler Size: # Haz/Non-Haz Piping Outlets: Appliance Exhaust Fan # Heater(Suspended,Floor,Recessed wall) # Boiler/Compressor Size: # Heating/Cooling appliance # re ration Evaporative Evaporative Cooler(attached,not # Pellet Stove/Wood-burning/Gas # portable) Fireplace Gas Stove/Gas Cook Stove/Misc. Fuel Gas Piping #of Outlets: Ventilation Fan,single duct # Furnace/Heat Pump/ Size: # Ventilation System # Forced Air Unit Plumbing Fixtures Indicate how many of each type of fixture to be installed or relocated Plumbing Traps # Fuel gas piping #of Outlets: Water Heater # Medical gas piping #of Outlets: Water Line # Plumbing Vent piping # Sewer Line # Industrial waste pretreatment interceptor Grease Trap) Size Other(describe): T:\BUILDING\APPLICATION FORMS\Current BP Application\Building Permit 4-17-13.docx s� r d _ ,yy 1 M 0 1 8Z M 2012 Washington State Energy Code: UA Alternative Worksheet,Type R-3 Occupancies Tikka Residence-Pro Proposed CITY OF PORT ANGELES—Conptruction Min,,; N ter^4+a these plans,Specifi- 1119 East Park Ave. The Issuance of this POW, cations and other dst• `-' r "^t the building official Port Angeles,WA 98362 from thereafter teat. �r tl.. (n "-a of errors in said plans, specipcations and o"`Ar r Ar horn preventing bilding operations G , ' erounder when in of all codes • :S of this jurisdiction. r(,,rcval Date `Y v Conditioned Floor Area 3,844 wD�� Conditioned Building Volume Weather Station Port Angeles Component Performance,R-3 occupancies Code Target Values Proposed Design Va Area UA Area UA Doors U= 0.300 158 47 158 80 Overhead Glazing U= 0.500 0 0 0 0 Vertical Glazing U= 0.300 577 173 850 412 Flat/Vaulted Ceilings U= 0.026 2,072 54 2,072 56 Wall(above grade) U= 0.056 2,935 164 2,662 144 Floors U= 0,029 2,073 60 2,073 60 Slab on Grade F= 0.540 0 0 0 0 Below Grade Wall U= 0.042 0 0 0 0 Below Grade Slab F= 0.570 0 0 0 0 Target UA Total 499 Proposed UA TotalF 751 Target Credits from Table 406.2 1.5 Proposed Credits from Table 406.2 1.5 If the Proposed UA<_the Target UA,and the Proposed Credits From Table 406.2 are?those required in Section R406.2 than the home meets the 2012 WSEC. Exterior Doors Plan Component Door Width Height ID Description Ref. U Qt. Feet inch Feet Inch Area UA Wood slab in wood frame(WoodSWF) 10-6C 0.46 4 3 ° 61 8 80 37 Wood slab in wood frame(WoodSWF) 10-6C 0.46 1 2 8 61 8 18 8 WoodSWF 2gl>50%1/2" 110-6A 0.58 3 3 ° 6 8 60 35 _ 0 0.00 0 0 0 0.00 0 0 00.00 0 0 -1 0 0.00 01 0 Sum of Area and UA 1 158 80 Overhead Glazing: Plan Component Glazing Width Height ID Description Ref. U Qt. Feet Inch Feet inch Area UA 0 0.00 0 0 0 0.00 0 0 7 0 0.00 0 0 0 0.00 0 0 v 0 0.00 0 0 Sum of Area and UA 0 0 Copyright 2013,WSUEEP10-009(version 11)Copied by permission from Washington State University Extension Energy Program. (see copyright restrictions) 6/23/2014 1 of 4 I 2012 Washington State Energy Code:UA Alternative Worksheet,Type R-3 Occupancies Vertical Glazing; Plan Component: Glazing Wldth Height ID _ _ _ _ Description _ Ref.; U Qt.:: Feet .':: Feet:.-n Area UA 291 Wood/Vinyl LowE+Argon<1/2"spacer 10-6A 0:53 3 4 ° 4 8 54 29' 2gI Wood/Vinyl LowE+Argon<1/2"spacer 10-6A 0.53 1 6 ° 4 ° 24 13 2gI Wood/Vinyl LowE+Argon>_1/2"spacer _ 10-6A. 0.48 2 6 ° 5 ° 60 2$ 2gI Wood/Vinyl LowE+Argon>_1/2"spacer V 10-6A,' 0.48 2 6 ° 2 ° 24 12' 2gl Wood/Vinyl LowE+Argon>_1/2"spacer _ 10-6A: 0,48 2 2 ° 3 ° 12 6 2gI Wood/Vinyl LowE+Argon>_1/2"spacer V :1 MA 0.48 5 6 ° 6 8 200 96' 2gI Wood/Vinyl LowE+Argon>_1/2"spacer . 10�A:; 0:48.. 1 6 ° 3 ° 2gI Wood/Vinyl LowE+Argon>_1/2^spacer 10 6A 0.48 1 4 ° 3 8 15 7 2gI Wood/Vinyl LowE+Argon>_1/2"spacer 10-6A: 0.48' 7 4 ° 6 ° 168 81; 2gI Wood/Vinyl LowE+Argon>_1/2"spacer 10 6A 0.48 2 4 ° 1 8 12 6 2gI Wood/Vinyl LowE+Argon>1/2"spacer 10-BA 0.4.8.' 2 4 ° 2 9 22 11 2gI Wood/Vinyl LowE+Argon>_1/2"spacer . 10.6A:i. 0.4:8, 2 4 ° 3 8 28 13 2gI Wood/Vinyl LowE+Argon>_1/2"spacer 10-6A, 0:48 1 3 ° 3 ° 9 4 2gI Wood/Vinyl LowE+Argon>_1/2"spacer 10-6A`: 048 2 3 ° 2 ° 12 ti 2gI Wood/Vinyl LowE+Argon>_1/2"spacer 10-6A 0.48' 5 2 ° 3 8 37 18 2gI Wood/Vinyl LowE+Argon>_1/2"spacer _ 10-6A' 0.48 1 8 ° 6 8 53 26 1 2gI Wood/Vinyl LowE+Argon>!1/2"spacer 10-6A 0.48 1 2 ° 6 ° 12 6 2gI Wood/Vinyl LowE+Argon>-1/2"spacer 10-6A. 0:48 5 3 01 6 ° -> 90 413 ------ � o aaol o 0 a :o 60 0 a 0 0.00' 0 0 0 0:00 0 0 0 oi0' a o' 0 no 0 0.40' a 0' 0 0001 o 4' w l6 4 0:00 0 0 0 <: 0;00' 0 0 a 0:00 a 0 0 0:00 0 0 0 0.00: 0 0 — ------------ 0 , : 0:00' 0 0 0 0:00 0 0 0 0.00' 0 0' 0 0.00 0 0: 0 0.00' 0 0' 0 0;00 0 ojj 0.. 0:00' 0 0. _ 0 0.60 0 0' 0 0.00 0 0' _ 0; 0.00 a 0 0 0.00 o a o 000 a o 0 0:00 0 0 0 00o a 4 _ _ o oao a a 0 0.001 0 0 — 0 o;io 0 0. o 0:40 0 4. o ooa o 4 0 0.04 0 0 - Sum of:Area and:UA 850 412 Glazin Area Weighted:U 0.485: Copyright 2013,WSUEEP10-009(Version.1.1)Copiedby permission from Washington State University Extension Energy Program. (see copyright restrictions) 8133/2014 2 of 4 14 2012 Washington State Energy Code:UA Alternative Worksheet,Type R-3 Occupancies FlaWa.ultetl Ceilings Plan Component:: Attic ID __Descri�pn„ Ref U Area UA R38 batt Vault unvented 2x12 24oc V 10 :x 0.027 736 "29. R49 blown Attic STD baffled 1047 0.027 1,336 36. ... 0.:. 0.000 0' 0 0.000 . O' Sum of Area and UA: 2;072 56 Walls(Above Grade} Plan I'l" Component' Wall; ID DescriptionRef. U Net Area UA _: R21 cavity+RO foam INT 2X6W lap 10-5 :' 0.054 2,662 144 0 0,000 0 _ 0 0.004 fl I II 0 0.000 0 Sum of Area and UA 2,662 144'. Floor(over crawl.r exterior) Plan Componen199 t= Floor Ip _- __.__-__---pesGnption! _ Ref. U Area JA . Rao vented Joist 16« 10.3 0.029 1,808 5r r 2 830 vented Joist 16« 10 3 0.029 265 - ------- -- • 0 0.000 0' 0 0.090 0' Stam of Area and UA 2',Q73 Slab an Grade(less than2 feet below graie) Plan Com9I I ponent, Slab Slab l0 Descriptiom' Ref9 FIrrI Lenc th UA .... 0: 0.000 0 --- --- ---- I 0 0.090 9 - --- - O 0.000 0 - - - - 0 0.000 0. Sum of Area and UA O 0' below Grade Walls and Slabs Plan Component! Wall;; Wall`:: Wallr r SlII ab Slab 51ab rrrr rr Ip _ _ D.escnphon ___ .. _ Ref. u.1.. Area: UA Fi. Len th UA 0 0.0901 O;p O.Q00: 0' -- - -- 0 :.... 0:00Q 0.0�II 0.000 ..0 — -- W O. :::: Q090 0'.Or.9I 0;000' 9 0 0.000! Q.O 9 0.000' 0'. Sum of Area,Length and UA 0 9.0 0 0 Copyright 2013,WSUEEP10-009(Version 11)Copied by permission from Washington State University Extension Energy Program. (see copyright restrictions) 6/23/2014 3 of 4 2012 Washington State Energy Code:UA Alternative Worksheet,Type R-3 Occupancies Table R406.2 Summary Qpt. Description Credit s to Efficient Building Envelope 1a! 1b Efficient Building Envelope Ili ❑ 16 Efficient Building Envelope 1c; 2.0 0' 2a jAir Leakage Control:and Efficient Ventilation 2a 0.5 ❑ 2b. Air Leakage Controland Efficient Ventilation 26:: 1.0: ::: ❑ 2c Air Leakage Control and Efficient Ventilation.2c 1.5. ❑ 3a High Efficiency HVAC 3a - 0.5, ❑'. 3b High Efficiency HVAC 3b 1.0 ? ❑. 3C High Efficiency HVAC 3c 2.0 ❑! 3d Nigh Efficiency HVAC 3d 1,0 Cl 1•a 4 High Efficiency HVAC Distribution System 1.0 5a Efficient Water Heating 0 5 0.5 6b Efficient Water Heating 1,6 ❑ 6 Renewable:Electric Energy::: 0.5 kVilh ❑'. Total Credits: 1.5 xRease refer to Table 8406.2 for complete option descriptions Copyright 2013,WSUEEP10-009(Version 11)Copied by permission from Washington State University Extension Energy Program. (see copyright restrictions) 6123/2014 4 of 4 2012 Washington State Energy Code:UA Alternative Worksheet,Type R-3 Occupancies Tikka Residence-Existing 1119 East Park Ave. Port Angeles,WA 98362 Conditioned Floor Area 3,344 Conditioned Building Volume 28,327 Weather Station Port Angeles Component Performance,R-3 occupancies Code Target Values Proposed Design Va Area: UA . Area VX, Doors U-0.300<0.300 ;58 17 5$ 27 Overhead Glazing U= D.500 0 0 0 0. Veitical Glazing U=::0.300 502 150 653 ...... 78.3 Fiat/Vaulted Ceilings U=::0.026 1,62 43 1;;672 82.' Wall:(.above grade) U= 0.056 2,5!12 14':1 2;361 222 Floors U= 0.029 1,672 48 1:;672 69 Slab on Grade F= 0;640. ': 0 D 0 D Below Grade Wall U= 0 042 0 0 0 D Below Grade Slab F=:0:5700 0 0 0' Target UA Tofal 406Proposed UA Total :1,182 Proposed Credits from Target Credits from Table 406.2 1.5 0,0 Table 406.2 If the Ptoposed UA s the Target;UA,and the Proposed Credits From Table 406.2 are>those required in Section R406.2 than: the Home meets the 2012 WSEC. Exterior Doors: Plan Component Door Width Height ID Description,__'` Ref. U:: Qt.' Feet t"`h Feet;i"`h Area UA Wood slab in wood frame(WoodSWF) w 10-66 0.46 2 3 0 6 81, 18 Wood slab in wood frame(WoodSWF) 16,6C:. 0.46. 1 2 8 6 8 -- — � 0 0.00::::: 0 0' 0..:: 0.00: — -- 0 0 0,00 00.00 0 0 Sum of Area and UA 58 27 Overhead Glazing Plan Component: Glazing Width Height ID Desai fion Ref U! Qt.: Feet t"`L Feet "� Area UA 0 OiD0 0 0' 0 0 Oi00' Q 0 — v 0 0':00 0 0 0 b0i 0 0' Sum of Area and UA 0 D' Copyright 2013,WSUEEPI0-009(Version 11)Copied by permission from Washington State University Extension Energy Program. (see copyright restrictions) 6/23/2014 1 of 4 2012 Washington State Energy Code:UA Alternative Worksheet,Type R-3 Occupancies Vertical Glazing Plan Component' Glazing Width Height Ip _ Oescnption-_ __ _ Ref. U; Qt;: Feet.'"`h Feet IncArea UA 1gl Aluminum Clear 10-6A 1.20' 4 4 ° 4 e 72 86 191 Aluminum Clear I MA 1:20 1 6 ° 4 ° 24 29; Igl Aluminum Clear V IMA. 1:20 4 6 ° 5 ° 120 144 1gl Aluminum Clear 10-6A 1:24' 3 6 ° 2 ° 36 .43 lgl Aluminum Clear — — 10-6A1.20' 3 2 ° 3 ° 18 22 1g1 Aluminum Clear 10-6A> 1.20' 3 6 ° 6 8 120 144 1gl Aluminum Clear — 10-6A: 1:20 1 6 ° 3 ° igl Aluminum Clear 1 MA. 1.20 1 4 ° 3 8 15 18 1gl Aluminum Clear _ 10 6A;;: 1.20 7 4 ° 6 ° 168 202' 1gl Aluminum Clear 10-6A 1.20 2 1 4 ° 1 s 12 1:4.. 191 Aluminum Clear 10-BA 1.20 2 4 ° 2 91 22 2$ 191 Aluminum Clear 10 6A 1.20' 2 4 ° 3 s 28 34 0 0.00' 0 0' 0 0.00: Q 0 0. 0:00 0 Q 0.00 0 0 0 0:00 Q 0. 0 0401 Q 0 -- — -- 0 0:00 0 0 -- 0 060 0 0' 0.00 0 0 0 :. 0;00 0 0 -- -- � 0 0:00' 0 0' --- — 0 0;00' 0 0 0 0;00 0 0 0 0:00' Q 0 0-001 0 01001 0 0 0: bio ' 0 0 v 0 0.00 0 0 v 0F. 0:00' Q 0. V 0 0.00 0 0 .0:00 0 0 0 0<00' Q 0 0 41001 0 0. v 0 0.00 0 0 0 0'x00 0 0 -- • 0 b.00 0 0' 0, 0.00 0 0 _ 0 0 0 0.00 Q 0 0' 0;00 0 0 -- 0 0.00 0 0 - ------I� 0 0':00 0 0 0 0:00' 0 0 0 0:00' Q 0 0 0:00 0 0 --- • 0. 0;00 0 0 ------ v 0 0:00' 0 9 0 0;00 0 0 00:00 0 0 0 0A0' 00 0 :;:; 0'x00' 0 0 0 b.00 0 0 v 0 0:00 0 0 Sum Of Area and;UA 653 783 GlazingArea;WeightedU 1.2b0 Copyright 2013,WSUEEPIO-009(Version 11)Copied by permission from:Washington.5tate University Extension Energy.Program. (See copyright restrictions) _ _. _.. _.. ;6123/2014 2 of 4 2012 Washington State Energy Code:UA Alternative Worksheet,Type R-3 Occupancies FlatrVaulted Ceilings Plan Component Attic> ID ::_ __ Description Ref..:: U..:: Area UAII R19 batt Vault vented 2x10 16oc • 10 7 fl.049 736 36 R19 blown Attic STD baffled • 1 Q 7 <: 0.049 936 46 • 0:1 0. a • 0—Hoo 0 Stun of Area and UA'::: 1;672 82 Walls(Above Grade) Plan ; Component Wa11 fD Desai tion Ref. ? U ' Net Area LIX. RI1 cavity+RO foam STD 2X4W T111 • 1Q-5 0,084 2,361 222 __ • 0 0.000 fl -- • 0 0.000 0' — - --—�• 0 0.000 0' Sum of Area and UA 2;361 222 Floor(over crawl or exterior) Plan:: Component Floor ID Desctkron._____--- Ref. U Area: UA R19 vented Joist 16oc — • 10.3 0 041 1,672 69 — — • 0 0.000 a • 0 0,000 0 • 0 0.000 0. Sum of Area and UA 1;672 69 Slab on Grade(less,thaW.2 feet below grade) Plan Component: Slab Slab ID Description. Ref. F Len th UA • 0 0.000 0 • Q 0.000 0' • 0 0.000 0' • 0 I. 0:000 Q Sum of Area and UA Below Grade Walls and Slabs: Rlan Component Wall'; Wall'. Wall> Slab Slab Slab ID Description' Ref. :; U Areai UA :F::; Leri th UA • 0 0.040: 0.0 0.000' 0 • 0 Q,000 O,fl 0:000' 0: _ .o .0.oaa o'.a 0,000 0 • 0 0.000 o.0 0.000 0 Sum of Area,Length and uA Copyright 2013,WSUEEP10-009(Version 11)Copied by permission from Washington State University Extension Energy Program. (see copyright restrictions) 6/23/2014 3 of 4 2012 Washington State Energy Code:UA Alternative Worksheet,Type R-3 Occupancies Table R406 2 Summary: Opt. Description' Credit s 1a Efficient Building Envelope 1a 0.5;'I ❑. 1b Efficient Building Envelope 1b 1,0. ❑, 1c Efficient Building Envelope 1c 2-0; ❑ 2a Air Leakage Contrgland Efficient Ventilation 2a 0.5 ❑ 2b Air Leakage Control:and Efficient Ventilation 2b::. 1.0 ❑ 26Air Leakage Controland Efficient Ventilation 2c< 1.5` ❑ 3a Hlgh Efficiency HVAC 3a,..: 0.$ ❑ 3b High Efficiency HVAC 3b 1 0; ❑ 3c High Efficiency HVAC 3c,. 2.Q ❑ 3d High Efficiency HVAC 3d 1,0 ❑ 4 High Efficiency HVAC Distribution System 1-0 ❑` 59 c enfrLWater Heating 0.5 ❑ 5b Efficient Water Healing 1.5: ❑ 6 Renewable Eiectric'Energy 0.5 kWh Total Credits 0.0 *Please;refer t©Table 8406.2 for complete option descnptrans Copyright 2013,WSUEEPIO-009(Version 11)Copied by permission from Washington State University Extension Energy Program. (see copyright restrictions) 6/23/2014 4 of 4 KED-TER CONSTRUCTION, INC. (360) 683-9719 Office 4304 Old Mill Rd. (360)457-2061 / Fax Port Angeles WA 98362 Sam & Annett Tikka ( Bid ) As Is June 30, 2014 CONTRACT VALUE 1 Excavation & Partial Demo 21,373 2 Demo Dump Fees (Allowance) 13,800 3 Boom Truck 2,300 4 Foundation Material & Labor 6,325 5 Patio Slab & Labor 5,818 6 Concrete Stoop& Plinths 3,335 7 Framing Material 18,259 8 Trusses 1,380 9 Decks& Railings 7,522 10 Siding & Exterior Trim 3,501 11 Windows 16,902 12 Exterior Doors (Allowance) 6,325 13 Interior Doors&Trim 17,558 14 Interior Pre- Finshing 5,980 15 Interior Underlayment 1,424 16 Plumbing 5,614 17 Electrical 21,611 18 Roofing 30 yr. Comp. 18,159 19 Heating 6,971 20 Gutters 2,117 21 Insulation 7,935 22 Tape&Texture 26,450 23 Cabinets&Counter Tops 23,000 24 Closet Kits 1,840 25 Painting 35,880 26 Sanakan & Dump Fees 2,875 27 Misc. Final Cleaning 2,875 28 Ked-Ter Labor 61,367 29 Fireplaces 19,042 30 Appliances(Allowance) 2,299 31 Garage Doors(Allowance) 1,380 32 Finish Hardware(Allowance) 2,300 33 Tile (Allowance) 863 34 Carpet(Allowance) 14,950 36 Vinyl (Allowance) 4,600 35 Light Fixtures (Allowance) 5,750 36 Plumbing Fixtures (Allowance) 8,050 37 Bath Hardware (Allowance) 2,875 38 Asbestos Inspection &Testing 1,320 39 Abestos Removal 8,435 40 Ked-Ter Labor 1,440 41 Architects Fees 5,175 42 43 44 SUBTOTAL 426,973 47 8.4% Sales Tax 35,866 ---------------------------- TOTALS 462,839 All LI DBE V. . A R C I3 I C T S 319 s.peabody,suite b;port angeles,wa 98362 360.452.6116/fax 360.452.7064 PLoject:.-PJ4//-A Project No. Sybiect: By: Date: '�IJ- Sheet / of Gaw. � l 5-t5' i eve► 1 r I LI NDBER � ,rq,M IH A R C H I-'i� 1' C T S. 319 S.Peabody,Suite B.,Port Angeles,V,"A 98362 360.452.6116/fax 360.452.7064 contact0lindarcl com/t- %-w.lin&-chcom- - Project: - "I � �J ProiectNo. Subject: �. � -l .. By: Date: AC--? 4-44 Sheet � of SHEAR WALL SLUVROARY W L H V V/L SW VH-WL/2 POST HOLD-DOWN P=Pr �� C 1 G 3 D 2 11 f 4- I it 7-4' 2 I V�)14-1 4-26 0Z HDV, I - IIALLOFTT/FEUYD TO)FORMS/SHEARWAL ti J* ' co E WALL'4' Li ' O O IUM4LLI4LL w Q a a Al M&M v� "MER b L SHEAR WALLS t UM PLY.8 M-a& CF UALLHAIL ALL WM4 bd w�u a PIS, p� gy p,, �T W AT b°Or- FOR tiMMr USE DF NO2 PROVIDE U2' METER ANCHOR s DOLTS AT 4$'OG MAWN SPACMG AT TME P;7tNDA s. s. s. ¢SHEAR� �� .4 FOR TIE DO"AT EACH END OF TME UMU.GEE PLAZA 3 I VI 6HEATNNG�A0 OM OP UALL. NAIL ALL UM&d WULS AT b'OG FOR UGE DF NO2 PRGNDE U2' W ETER ANCHOR 80LT8 AT 31'OC WMAIBPAGNG AT RE FOIOi>A?I FOR TE DOIIN$At EAAI END OF TME UALL 8EE PLANS. 4 MUM GFEAR.36 PIP. USE IR'SNEATNG•aE SIDE OF UALL NA0.ALL M Od MMA 3� y AT 6'OG pGR PRW11W$USE DP NO2 PT00VIDE la Wee AWWOR DOLTS AT 92'OG MA18PAyCNG AT Ti!PO1lpATl FM 1E DOUNS At AAAI END OP?ME UALL,SEE PLANA 6. MAXMJ'T SHEAR•316 PLP. USE IR'"AIM-ONE 6M OF UAW. NAIL ALL UM Gd NAU AT 4'Of, FOR FRAMN USE DF NO2 PROVIDE V1' W'EER ANCHOR BOLTS AT 74'OG MAX Mp1$PACMG AT TFE FOI6DATI FORTE DO"AT EACH END OF TFE UALL,GEE A 13k� A I IR MUMS �6M OF UALL NAL ALL Sd N41L8 r AT 3'O:C. FOR FRAMNG UGE 9Jt DF NO2 DOUBLE BOTTOM PLATES ARE M ROMPED,DOLT TNROU4II BOTH PLAN UA1N ANCHOR DOLTS PROVIDE 6/$'DW VM AMM BOLT$AT 37'OA MAXMM GPACM AT TME FOJWATIOK FOR TE WIM AT EACH END Q:THE WALL, F� SEE FRAYINGS AR FLAM 8 PIUMH&PAR a 60 PLP. USE VA'"ATNG-ONE$IDE OF UAW. NAL ALLEDGE$UM IOd NA0.$ APLAYM�$ 90LT TFIR0 1 PLOF ANSS M02. N WITCH LT& � PROVIDE 6/$'DIMETER ANCHOR BOLTS AT 70'O.0.MAWUMM GPACNG A?M PaUNDATIOK FOR TE DOM AT EACH 00 CP M UAL , GEE H MNG9MEAR FLAW IL rAXMrt SNEAK•WO PLR USE IR'S EATNG-DOTH MM of®ALL. NAL ALL EDGES UaTN Gd NAU AT 3'0r-STAGGE REP. FOR FRAMNG USE 3X DF NO3. D01 'E BOROM P1+4TE8 AAE PEQU98=D,BOLT TF187UCN BOTH PL4In WiN ANCHOR of PROVIDE 3/4'DIAMM ACWR BOLTS AT V Of.MUM SPACNG AT nE FMMTIOK FOR TE DOM AT EACH END OF M UW.L, PRATM AR FL" LOWER LEVEL SHEAR WALL PLAN GC"V4'°I'-W .1 f WALL W SWEARWALL +' c r� b r `v N � WALL,\`_`/ B' BNEM WALL W IME2 6 gat k g< L 1:1 o SHEAR WALLS � 2 MAX"jm SHEAR.90O PLP. UBE W.SFEAIMG-01E SCE OF WALL NAIL ALL EDXM WTH 6d NAILS awl q AT 8 OG. POR PRAM6Ka USE DF NO2 PROVIDE VJ DIAMETER ANCHOR P. 11 MOLTS AT 46.OD.MAXW99M SPAGNG AT THE iOUNDATICPL SHEAR WAIL FOR TIE W1W AT EACH Elm OF THE UWLL,SEE FRAI'p&SWEAR PLANE. d o ❑ ❑ ❑ d NYMBER 8 e 3 "ft" •960 W. UK W.SFIEATMG-OR SIDE OF WALL NAIL ALL EDGES WTH ed NAILS �' ,- ��A �ES BBOLTB T 9Y'D'M1 1'8PAACC1�6 AT THE POUMDATWK��R FOR TE DO"AT EACH END OF THE WALL,SEE FRAMWN'slBFM PLANS. qi 4. MAXM9'I SHEAR-35 PLP. � � w UBE LZ'8i4tATMG-CNE BIDE OF WALL NAIL ALL EDGER WTH Bd NAILS AT 9'OG FOR FRAIHNd W DT'N01. PIB7VIDE Vt'DAMEIBF ANCHOR BOLTS AT 39'O.C.MAX14M SPACMG AT TFM POUmATION - POR TIE Pa"AT EACH END OP THE IW1LL,60 FRAI'BW"WAR KA M S. MA�GT4M BNEAR•3T6 PLP. USE IR'BHEATM9-CNC SIDE OP WALL NAIL ALL EDGES WTH M W UL6 AT 4'OA". FOR FRAMNG,UBE DF N01. PROVIDE 62'DWSM R AWWOR BOLTS AT 94■OC MAJt!�9M BPAGNG aT THE FOMATOL FOR TLE MW AT EACH END OF THE WALL„80 FRAMIIGSWAIE PLANS. 6. MAX"M SWEAR-490 PLP. USE Wo SWEATM6-OW SIDE OF W4LL NAIL ALL EDGER WTN Sd NAILS AT 3■Or- FOR PRAMM USE 3X DF N0I DOUBLE BOTTOM PLATER ARE REfUMED,BOLT THRCUC�I BOTH PLATES WTH ANCHOR BOLTS. PROVVE SAB°DLAMEIER"NOR BOLTS AT 31'OL-MAXMUM SPACMG AT THE � 80 AT T PL AT EACH END OF INE Ut4LL C� a MAX�"nJM$ EAR•686 PLP. 114E 1*1 BHFATMG-Q6:6M OF WALL NAIL ALL EDGES WTH IOd NAILS � AT 2 W'Or—STAGGER°.A. F10R FRAMMG,USE 3X OF NO2 Dans WffCM PLATER ARE RF lSiEG BOL7 TIASMW BOTH PLATER WITH ANCHOR WXM FM90NDE SIS"DAMETER ANCHOR DOLTS AT 90'=MAXMUM SPAC613 AT THE FOUmATTON FOR TIE DOM AT EACH END OF THE WAIJ-, r l SEE RtM*Y%/B M FLANS. M IL MAXIMU16FFAR-960 PI UBE 04 BHEATMG-BOTH WES OF WALL. NAW.ALL EDGER UTH Sd NAILS AT 3■OG STAGGERED. FOR LIGE 3X DF NOT. DOUBLE BOTTOM BM PLATER ARE REMPRED,BOLT PLATER MM ANOIIOR BOLTS. PROVVE A POUOAT"TIE POIW6�ATT AEACH END FOP IMMIMWIACING BEE FRAP9NAMMEAR PLANS, UPPER LEVEL SHEAR WALL PLAN SCALE=V4'.1'-0' I b 6HEAR WALLS 2. MAXIMUM SHEAR = 200 P.L.F. USE 1/2" SHEATING - ONE SIDE OF WALL. NAIL ALL EDGES WITH 6d NAILS AT 6" O.C. FOR FRAMING, USE DF NO2. PROVIDE 1/2" DIAMETER ANCHOR BOLTS AT 48" O.C. MAXIMUM SPACING AT THE FOUNDATION. FOR TIE DOWNS AT EACH END OF THE WALL, SEE FRAMING/SHEAR PLANS. 3. MAXIMUM SHEAR = 250 P.L.F. USE 1/2" SWEATING - ONE SIDE OF WALL. NAIL ALL EDGES WITH 8d NAILS AT 6" O.G. FOR FRAMING, USE DF NO2. PROVIDE 1/2" DIAMETER ANCHOR BOLTS AT 32" O.C. MAXIMUM SPACING AT THE FOUNDATION. FOR TIE DOWNS AT EACH END OF THE WALL, SEE FRAMING/SHEAR PLANS. 4. MAXIMUM SHEAR = 315 P.L.F. USE 1/2" SHEATING - ONE SIDE OF WALL. NAIL ALL EDGES WITH Sd NAILS AT 5" O.C. FOR FRAMING, USE DF NO2. PROVIDE 1/2" DIAMETER ANCHOR BOLTS AT 32" O.C. MAXIMUM SPACING AT THE FOUNDATION. FOR TIE DOWNS AT EACH END OF THE WALL, SEE FRAMING/SHEAR PLANS. 5. MAXIMUM SHEAR = 315 P.L.F. USE 1/2" SHEATING - ONE SIDE OF WALL. NAIL ALL EDGES WITH 8d NAILS AT 4" O.G. FOR FRAMING, USE DF NO2. PROVIDE 1/2" DIAMETER ANCHOR BOLTS AT 24" O.C. MAXIMUM SPACING AT THE FOUNDATION. FOR TIE DOWNS AT EACH END OF THE WALL, SEE FRAMING/SHEAR PLANS. 6. MAXIMUM SHEAR = 490 P.L.F. USE 1/2" SHEATING - ONE SIDE OF WALL. NAIL ALL EDGES WITH Sd NAILS AT 3" O.C. FOR FRAMING, USE 3X DF NO2. DOUBLE BOTTOM PLATES ARE REQUIRED, BOLT THROUGH BOTH PLATES WITH ANCHOR BOLTS. PROVIDE 5/8" DIAMETER ANCHOR BOLTS AT 32" O.C. MAXIMUM SPACING AT THE FOUNDATION. FOR TIE DOWNS AT EACH END OF THE WALL, SEE FRAMING/SHEAR PLANS. 8. MAXIMUM SHEAR = 685 P.L.F. USE 1/2" SHEATING - ONE SIDE OF WALL. NAIL ALL EDGES WITH lOd NAILS AT 2 1/2" O.C. STAGGERED. FOR FRAMING, USE 3X DF NO.2. DOUBLE BOTTOM PLATES ARE REQUIRED, BOLT THROUGH BOTH PLATES WITH ANCHOR BOLTS. PROVIDE 5/8" DIAMETER ANCHOR BOLTS AT 20" O.G. MAXIMUM SPACING AT THE FOUNDATION. FOR TIE DOUNS AT EACH END OF THE WALL, SEE FRAMING/SHEAR PLANS. 11. MAXIMUM SHEAR = 980 P.L.F. USE 1/2" SHEATING - BOTH SIDES OF WALL. NAIL ALL EDGES WITH 8d NAILS AT 3" O.C. STAGGERED. FOR FRAMING, USE 3X DF NO2. DOUBLE BOTTOM PLATES ARE REQUIRED, BOLT THROUGH BOTH PLATES WITH ANCHOR BOLTS. PROVIDE 3/4" DIAMETER ANCHOR BOLTS AT 18" O.C. MAXIMUM SPACING AT THE FOUNDATION. FOR TIE DOWNS AT EACH END OF THE WALL, SEE FRAMING/SHEAR PLANS. Address: 1119 E Park Avenue ( 1 ( I C-- _ PA-.r 1L- A�.r (- - PREPARED 5/01/15, 8:33:16 INSPECTION TICKET PAGE 3 CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 5/01/15 ----- - ----------------- ----- ADDRESS . : 1119 E PARK AVE SUBDIV: CONTRACTOR KED/TER CONSTRUCTION INC PHONE (360) 460-0139 OWNER TIKKA SAMUEL J PHONE PARCEL 06-30-11-5-1-0690-0000- APPL NUMBER: 14-00001202 PLUMBING PERMIT ------------------------------------------------------------------------------------------------ PERMIT: PL 00 PLUMBING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ PL99 01 10/06/14 JLL PLUMBING FINAL 10/06/14 AP October 6, 2014 1:42:20 PM permits. October 6, 2014 1:42:37 PM permits. PL99 02 5/01/15L PLUMBING FINAL May 1, 2015 8:36:36 AM jlierly. ------------------------- - ---------- COMMENTS AND NOTES -------------------------------------- CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY&ECONOMIC DEVELOPMENT- BUILDING DIVISION ® n 321 EAST 5TH STREET, PORT ANGELES,WA 98362 Application Number . . . . . 14-00001202 Date 10/06/14 4 Application pin number . . . 057054 Property Address . . . . . . 1119 E PARK AVE ASSESSOR PARCEL NUMBER: 06-30-11-5-1-0690-0000- REPORT SALES TAX Application type description PLUMBING PERMIT Subdivision Name . . . . . . on your state excise tax form Property Use . . . . . . . . to the Cit of Port Angeles Property Zoning . . . . . . . UNKNOWN Y 9 Application valuation . . . . 2500 (Location Code 0502) ---------------------------------------------------------------------------- Application desc Replace and add dwv ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ `�- TIKKA SAMUEL J KED/TER CONSTRUCTION INC 1119 E PARK AVE 4304 OLD MILL RD \ PORT ANGELES WA 983622740 PORT ANGELES WA 98362 (360) 460-0139 ---------------------------------'------------------------------------------- Permit . . . . . . PLUMBING PERMIT Additional desc REPAIR AND ADD DWV Permit Fee . . . . 92.00 Plan Check Fee .00 Issue Date . . . . 10/06/14 Valuation . . . . 0 Expiration Date . . 4/04/15. Qty Unit Charge Per Extension BASE FEE 50.00 3.00 7.0000 EA PL-PLUMBING TRAP 21.00 1.00 7.0000 EA PL-WATER LINE 7.00 1.00 7.0000 EA PL-DRAIN VENT PIPING 7.00 1.00 7.0000 EA PL-WATER HEATER 7.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 92.00 92.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 92.00 92.00 .00 .00 Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local la lating const uction or the performance of construction Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder) T:Forms/Building Division/Building Permit BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS Building Inspections 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION: Footings Stemwall Foundation Drainage/Downspouts Piers Post Holes(Pole Bldgs.) PLUMBING: Under Floor/Slab Rough-in Water Line Meter to Bid Gas Line Back Flow/Water FINAL Date Accepted b AIR SEAL: Walls Ceiling FRAMING: Joists/Girders/Under Floor Shear Wall/Hold Downs Walls/Roof/Ceiling Drywall Interior Braced Panel Only) T-Bar INSULATION: Slab Wall/Floor/Ceiling MECHANICAL: Heat Pum /Furnace/FAU/Ducts Rough-In Gas Line Wood Stove/Pellet/Chimney Commercial Hood/Ducts FINAL Date Accepted b MANUFACTURED HOMES: Footing/Slab Blocking&Hold Downs Skirting PLANNING DEPT. Separate Permit#s SEPA: Parkin /Lighting ESA: Landscaping SHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE Inspection Type Date Accepted By Electrical 417-4735 Construction-R.W. PW /Engineering 417-4831 Fire 417-4653 Planning 417-4750 Building 417-4815 T:Forms/Building Division/Building Permit THEOR + NGELES For City Use CITY OF �1 JJ,, lei Permit# /2 WASH INGTO N , U . S. Date Received: 1- 321 E 5th Street Date Approved Port Angeles,WA 9836 P:360-417-4817 F:360-417-4711 Email:permits@cityofpa.us BUILDING PERMIT APPLICATION Project Address: Phone: K,�,O Primary Contact: Email: Name Phone Property Mailing 4ddressEmail Owner City d of State 11 Zi Z Name Phone r� Contractor Address ; / Email Information City ' �/ , es( State Zip � z Contractors License# Exp.Date: Legal Description: Zoning: Tax Parcel# Project Value: (materials and labor) Residential 0 Commercial ❑ Industrial ❑ Public ❑ Permit Demolition ❑ Fire ❑ Repair Reroof(tear off/lay over) ❑ Classification For the following,fill out both pages of permit application: (check New Construction ❑ Exterior Remodel 4 Addition KI Tenant Improvement ❑ appropriate) Mechanical ❑ Plumbing )�l Other ❑ Fire Sprinkler System? Irrigation System? Proposed Bathrooms Proposed Bedrooms Yes 0 No P I Yes 0 No 1% Project Description Is project in a Flood Zone: Yes ❑ NoO Flood Zone Type: If in a Flood Zone,what is the value of the structure before proposed improvement? $ I have read and completed the application and know it to be true and correct.I am authorized to apply for this permit and understand that it is my responsibility to determine what permits are required and to obtain permits prior to work. I understand that plan review fees are not refundable after review has occurred. I understand that I will forfeit review fees if I withdraw the application before the permit is issued. I understand that if the permit is not picked up/issued within i8o days of submittal,the application will be considered abandoned and the fees will be forfeited. Date Print Name Siat Residential Structures For Office Use Area Description(SQ FT) Existing Proposed ss value Basement First Floor Second Floor Covered Deck/Porch/Entry Deck(over 30"or . floor) �.. Garage Carport Other(describe) Area Totals Commercial Structures For Office Use Area Descriptions(SQ FT) Existing Proposed $$Value Existing Structure(s) Proposed Addition Tenant Improvement? Other work(describe) Site Area Totals Lot/Site Covera a Calculations Lot Size(sq ft) Lot Coverage(sq ft) %Lot Coverage(Total lot coverage_lot size) Site Coverage(Sq Ft of all impervious) %of Site Coverage(total site coverage_lot size) Mechanical Fixtures Indicate how many of each type of fixture to be installed or relocated as part of this project. Air Handler Size: # Haz/Non-Haz Piping Outlets: Appliance Exhaust Fan # Heater(Suspended,Floor,Recessed wall) # Boiler/Compressor Size: # Heating/Cooling appliance # re ration Evaporative Evaporative Cooler(attached,not # Pellet Stove/Wood-burning/Gas # portable) Fireplace/Gas Stove/Gas Cook Stove/Mise. Fuel Gas Piping #of Outlets: Ventilation Fan,single duct # Furnace/Heat Pump/ Size: # Ventilation System # Forced Air Unit Plumbing Fixtures Indicate how many of each type of fixture to be installed or relocated Plumbing Traps # Fuel gas piping #of Outlets: Water Heater # Medical gas piping #of Outlets: Water Line # Plumbing Vent piping # Sewer Line # Industrial waste pretreatment interceptor Grease Trap) Size Other(describe): T:\BUILDING\APPLICATION FORMS\Current BP Application\Building Permit 4-17-13.docx