PREPARED 7/02/14, 13:27:58 INSPECTION TICKET PAGE 1
CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 7/02/14
-------------—--—-—-—------------------------------—---------------------—- --------
ADDRESS 1206 FOREST TR SUBDIV:
CONTRACTOR PHONE
OWNER Scott Adams PHONE
PARCEL 06-30-14-6-7-0220-0000-
APPL NUMBER: 13-00001413 RES NEW SFR
------------------------------------------------------------------------------------------------
PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
--------------------------—---------------------—------------------------------ -------
BL1 01 2/14/14 JLL BLDG FOUNDATION FOOTING
2/14/14 AP February 14, 2014 8:54:44 AM pbarthol.
George 253-377-0453
*** The site set of plans are in Puyallup. Take file set if
needed. (plans filed with permit)
February 14, 2014 4:08:38 PM jlierly.
BL2 01 2/18/14 JLL BLDG FOUNDATION STEM WALL
2/18/14 AP February 18, 2014 9:45:34 AM pbarthol.
George 253-377-0453
February 18, 2014 4:12:39 PM jlierly.
BFF O1 3/11/14 JLL BLDG FLOOR FRAMING
3/11/14 AP March 11, 2014 1:48:57 PM pbarthol.
justin 253-677-6822
March 11, 2014 4:34:57 PM jlierly.
BL9 01 3/17/14 JLL BLDG SHEARWALL
3/17/14 AP March 17, 2014 11:59:49 AM pbarthol.
justin 253-677-6822
March 17, 2014 4:40:55 PM jlierly.
BAIR O1 4/14/14 JLL BLDG AIR SEAL
4/14/14 AP April 14, 2014 11:59:48 AM pbarthol.
JOSH 253-606-8572
April 14, 2014 4:21:53 PM jlierly.
BL3 01 4/14/14 JLL BLDG FRAMING
4/14/14 AP April 14, 2014 4:21:53 PM jlierly.
BLI O1 4/30/14 JLL BLDG INSULATION
4/30/14 AP April 30, 2014 1:32:50 PM pbarthol.
Josh 253-606-8572
April 30, 2014 4:16:00 PM jlierly.
PW99 01 6/30/14 RV PUBLIC WORKS FINAL
6/30/14 AP July 1, 2014 7:13:33 AM rvess.
July 1, 2014 7:13:56 AM rvess.
BL99 01 7/02/14J L BLDG FINAL
July 2, 2014 10:17:26 AM pbarthol.
Rex 360-915-2733
------------------------------------------------------------------------------------------------
PERMIT: ME 00 MECBANICAL PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
----------------------------------------------------- -------------------------------------
ME1 01 4/14/14 JLL MECHANICAL ROUGH-IN
4/14/14 AP April 14, 2014 12:02:43 PM pbarthol.
JOSH 253-606-8572
April 14, 2014 4:21:53 PM jlierly.
ME99 01 7/02/14 MECHANICAL FINAL
July 2, 2014 10:17:51 AM pbarthol.
PERMIT: PL 00 PLUMBI G RMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
----------------------------------- CONTINUED ONTO NEXT PAGE -----------------------------------
PREPARED 7/02/14, 13:27:58 INSPECTION TICKET PAGE 2
CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 7/02/14
------------------- ----
ADDRESS . : 1206 FOREST TR SUBDIV:
CONTRACTOR : PHONE
OWNER Scott Adams PHONE
PARCEL 06-30-14-6-7-0220-0000-
APPL NUMBER: 13-00001413 RES NEW SFR
------------------------------------------------------------------------------------------------
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
--------------------------—-------------— ---------------—
PL2 01 4/14/14 JLL PLUMBING ROUGH-IN
4/14/14 AP April 14, 2014 12:02:13 PM pbarthol.
JOSH 253-606-8572
April 14, 2014 4:21:53 PM jlierly.
PL6 01 4/18/14 JLL PLUMBING WATER SUPPLY
4/18/14 AP April 18, 2014 10:03:47 AM pbarthol.
jim 477-1581
April 18, 2014 4:47:09 PM jlierly.
July 2, 2014 10:18:23 AM pbarthol.
PL99 01 7/02/14 PLUMBING FINAL
July 2, 2014 10:18:33 AM pbarthol.
--------------------- -- - ----------- COMMENTS AND NOTES -----------------------
`= CITY OF PORT ANGELES
s ! DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT- BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES, WA 98362
Application Number . . . . . 13-00001413 Date 1/06/14
Application pin number . . . 242282
Property Address . . . . . . 1206 FOREST TR
ASSESSOR PARCEL NUMBER: 06-30-14-6-7-0220-0000-
Application type description RES NEW SFR REPORT SALES TAX
Subdivision Name . . . . . . on your state excise tax form
Property Use . . . . . . . .
Property Zoning . RS9 RESDNTL SINGLE FAMILY to the City of Port Angeles `\I
Application valuation 165282 (Location Code. 0502)
Application desc
New single family residence
----------------------------------------------------------------------------
Owner Contractor
Scott Adams OWNER
PO BOX 1527
PORT ANGELES WA 983620312
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT -RESIDENTIAL
Additional desc . . SFR
Permit Fee . . . . 1501.85 Plan Check Fee 976.20
Issue Date . . . . 1/06/14 Valuation . . . . 185282
Expiration Date . . 7/05/14
Qty Unit Charge Per Extension
BASE FEE 1020.25 \\\
86.00 5.6000 THOU BL-100,001-500K (5.60 PER K) 481.60
------------------------------------ --
Permit . . . . . . MECHANICAL PERMIT
Additional desc . . SFR
Permit.Fee . . . . 226.25 Plan Check Fee .00
Issue Date . . . . 1/06/14 Valuation . . . . 0
Expiration Date . . 7/05/14
Qty Unit Charge Per Extension
BASE FEE 50.00
3.00 7.2500 EA ME-VENT FAN (SINGLE DUCT) 21.75
1.00 10.6500 EA ME-HOOD/DUCT-MECH. EXHAUST 10.65
1.00 10.6500 EA ME-STOVE/FIREPLACE/MISC. APP. 10.65
9.00 14.8000 EA ME-HEATER(SUSP/WALL/FLOOR-MTD) 133.20
----------------------------------------------------------------------------
Permit . . . . . . PLUMBING PERMIT
Additional desc SFR
Permit Fee . . . . 163.00 Plan Check Fee .00
Issue Date . . . . 1/06/14 Valuation . . . . 0
Expiration Date . . 7/05/14
Qty Unit Charge Per Extension
BASE FEE 50.00
8.00 7.0000 EA PL-PLUMBING TRAP 56.00
1.00 7.0000 EA PL-WATER LINE 7.00
4.00 7.0000 EA PL-DRAIN VENT PIPING 28.00
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of ny tate or local law regulating construction or the performance of
construction.
11 1-161lq SC,077-1w,,
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
V t .�• n
BUILDING PERMIT INSPECTION RECORD
PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS—
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL,TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs)
PLUMBING:
Under Floor/Slab
Rough-in
Water Line(Meter to Bldg)
Gas Line
Back Flow/Water FINAL Date Accepted by
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall(Interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pum /Furnace/FAU/Ducts
Rough-In
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts FINAL Date Accepted by
MANUFACTURED HOMES:
Footing/Slab
Blocking&Hold Downs
Skirting
L
LANNING DEPT. Separate Permit#s SEPA:
Parking/Lighting ESA:
andscaping SHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction- R.W. PW /Engineering 417-4831
Fire 417-4653
Planning 417-4750
Building 417-4815
'r CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY& ECONOMIC DEVELOPMENT- BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES, WA 98362
Page 2
Application Number . . . . . 13-00001413 Date 1/06/14
Application pin number . . . 242282
Qty Unit Charge Per Extension REPORT SALES TAX
1.00 15.0000 EA PL-SEWER LINE 15.00 on your state excise tax form
1.00 7.0000 EA PL-WATER HEATER 7.00
--- ------------- - --- ---------------------- to the City of Port Angeles
Special Notes and Comments (Location Code OSOZ)
December 10, 2013 10:20:59 AM tamiot.
new underground service from existing service pedestal.
electrical permit will be required.
Address numbers shall be plainly visible from the street.
Address numbers shall be a minimum of six inches high and be
of contrasting color from the background.
December 10, 2013 10:24:09 AM sroberds.
The proposal will result in a new sfr in the RS-9. Lot cov
will be 15% and site cov is 23%-. No land use issues are
anticipated.
Ditches & 8" culverts will be installed to City Stanards.
See Public Works Engineering for Standards.
Consider applying for the City Green Infrastructure Rebate
of up to $750.00 towards the materials to install rain
garden to control roof and driveway runoff. Also rebates
available for downspout disconnections.Contact Jonathan
Boehme at 360 417-4811
Trench safety per applicable laws. Temp erosion control and
surface restoration responsibility of applicant. Contact
City inspector prior to start of work @ 360 417-4831. No
attachment to sanitary sewer of stormwater roof leaders,
foundation drains, yard drains, or any other CSO
contribution is allowed.
Sanitary sewer connection inspection is required by
Public Works prior to back fill of ditch. 24 hour advance
notice is required. Public Works Inspection request line
417-4831
Owner responsible to adjust water meter setter, service line
and meter box to finish grade, maintain 6 inches of
clearance from bottom of meter box lid and top of meter.
Construct driveway to City Standards. Concrete with exposed
aggregate or other non-standard finishes(including colors or
dyes)are not allowed in the City road right of way. Broom
finish only. An inspection by Public Works Engineering is
required prior to pouring concrete. Public Works inspection
request line 417-4831
----------------------------------------------------------------------------
Other Fees . . . . . . . . . RES UNDERGRND SERVICE FEE 770.00
SEWER SYSTEM DELV CHARGE 2260.00
STATE SURCHARGE 4.50
PW WATER SYSTEM USE FEE 2260.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
Permit Fee Total 1891.10 1891.10 .00 .00
Plan Check Total 976.20 976.20 .00 .00
Separate Permits are required forelectrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
BUILDING PERMIT INSPECTION RECORD
PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS—
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 4174831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL,TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-In
Water Line(Meter to Bldg)
Gas Line
Back Flow/Water FINAL Date Accepted by
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall(Interior Braced Panel Only
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pum /Furnace/FAU/Ducts
Rough-In
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts FINAL Date Accepted by
MANUFACTURED HOMES:
Footing/Slab
Blocking&Hold Downs
Skirting
PLANNING DEPT. Separate Permit#s SEPA:
Parkin /Lighting ESA:
Landscaping SHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction- R.W. PW I Engineering 417-4831
Fire 417-4653
Planning 417-4750
Building 417-4815
T'Fnrmc/Rnilrlinn hivic inn/Rnilriir..,D-if
CITY OF PORT ANGELES
® DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT- BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES, WA 98362
Page 3
Application Number . . . . . 13-00001413 Date 1/06/14
Application pin number . . . 242282
Other Fee Total 5294.50 5294.50 .00 .00 REPORT SALES TAX
Grand Total 8161.80 8161.80 .00 .00
on your state excise tax form
to the City of Port Angeles
(Location Code 0502)
Separate Permits are required forelectrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
BUILDING PERMIT INSPECTION RECORD
PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS—
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL.TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-in
Water Line(Meter to Bldg)
Gas Line
Back Flow/Water FINAL Date Accepted by
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceilin
Drywall(Interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pum /Furnace/FAU/Ducts
Rough-in
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts FINAL Date Accepted by
MANUFACTURED HOMES:
[Footing/Slab
lockin &Hold Downs
kirting
PLANNING DEPT. Separate Permit#s SEPA:
Parking/Li htin ESA:
Landscaping SHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction- R.W. PW /Engineering 417-4831
Fire 417-4653
Planning 417-4750
Building 417-4815
O4 p0Ri,y1,0
V T�` CITY OF PORT ANGELES
NN
,�1ip PUBLIC WORKS & UTILITIES
321 EAST 5TH STREET, PORT ANGELES, WA 98362
Application Number . . . . . 13-00001413 I Date 1/06/14
Application pin number . . . 242282
AddressProperty
ASSESSOR PARCELNUMBER: 06-30-14-6 -
-70220-0000- REPORT SALES TAX
Application type description RES NEW SFR on your state excise tax form
SubdProperty
Name . . . . . . to the City of Port Angeles
Pro ert Use ,,l c
Property Zoning . . . . . . RS9 RESDNTL SINGLE FAMILY (Location Code OJOZ)
Application valuation . . . . 185282
--------------------
Application desc
New single family residence
----------------------------------------------------------------------------
Owner Contractor
----------
Scott Adams OWNER
PO BOX 1527
PORT ANGELES WA 983620312
----------------------------------------------------------------------------
Permit . . . . . . DRIVEWAY INSTALLATION
Additional desc . .
Permit Fee . . . . 180.00 Plan Check Fee .00
Issue Date . . . . 1/06/14 Valuation 0
Expiration Date 7/05/14
Qty Unit Charge Per Extension
BASE FEE 180.00
----------------------------------------------------------------------------
Permit . . . . . . PUBLIC WORKS RES WATER SERV
Additional desc . . 5/8 " DROP IN METER
Permit Fee . . . . 420.00 Plan Check Fee 00
Issue Date . . . . 1/06/14 Valuation . . . . 185282
Expiration Date 7/05/14
Qty Unit Charge Per Extension
1.00 420.0000 EA PW WATER METER DROP IN 420.00
----------------------------------------------------------------------------
Permit . . . . . . SANITARY SEWER HOOK UP
Additional desc .
Permit Fee . . . . 150.00 Plan Check Fee .00
Issue Date . . . . 1/06/14 Valuation . . . . 185282
Expiration Date . . 7/05/14
Qty Unit Charge Per Extension
1.00 150.0000 EA SAN SEWER HOOKUP 150.00
----------------------------------------------------------------------------
Special Notes and Comments
December 10, 2013 10:20:59 AM tamiot.
new underground service from existing service pedestal.
electrical permit will be required.
Address numbers shall be plainly visible from the street.
Address numbers shall be a minimum of six inches high and be
of contrasting color from the background.
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned
for a period of 180 days after the work as commenced,or if required inspections have not been requested within 180 days from the last
inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of
laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the provisions of any state or--local law reg\ng construction or the performance of
construction.
Signature of Contractor or Authorized Agent Date lSignature of Owner(if owner is builder) Date
T:Forms/Building Division/Public Works Permit
PERMIT INSPECTION RECORD
CALL 417-4831 FOR UTILITY INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVEK,
INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INA CONSPICUOUS LOCATION.
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE
INSPECTION TYPE DATE ACCEPTED COMMENTS
YES NO
PW UTILITIES (Engineering Division)
WATERLINE/METER
SEWER CONNECTION
SANITARY
STORM
SITE DRAINAGE
SITE EROSION CONTROL
PARKING
SIDEWALK
CURB&GUTTER
DRIVEWAY APPROACH
BACK-FLOW DEVICE
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED
YES NO
CONSTRUCTION R.W./PW/ CONSTRUCTION-R.W.
ENGINEERING 417-4807 PW/ENGINEERING
FIRE 417-4653 FIRE DEPT.
PLANNING DEPT. 417-4750 PLANNING DEPT.
BUILDING 41,7- BUILDING
4815
T:Forms/Building Division/Public Works Permit
yQf pOftigNCe( CITY OF PORT ANGELES
PUBLIC WORKS & UTILITIES
321 EAST 5TH STREET, PORT ANGELES, WA 98362
Page 2
Application Number . . . . . 13-00001413 Date 1/06/14
Application pin number . . . 242282
-------------------------------------------------------------------- REPORT SALES TAX
Special Notes and Comments on your state excise tax form
December 10, 2013 10:24:09 AM sroberds.
The proposal will result in a new sfr in the RS-9. Lot cov to the City of Port Angeles
will be 15% and site cov is 23%. No land use issues are
anticipated. (Location Code 0502)
Ditches & 8" culverts will be installed to City Stanards.
See Public Works Engineering for Standards.
Consider applying for the City Green Infrastructure Rebate
of up to $750.00 towards the materials to install rain
garden to control roof and driveway runoff. Also rebates
available for downspout disconnections.Contact Jonathan
Boehme at 360 417-4811
Trench safety per applicable laws. Temp erosion control and
surface restoration responsibility of applicant. Contact
City inspector prior to start of work @ 360 417-4831. No
attachment to sanitary sewer of stormwater roof leaders,
foundation drains, yard drains, or any other CSO
contribution is allowed.
Sanitary sewer connection inspection is required by
Public Works prior to back fill of ditch. 24 hour advance
notice is required. Public Works Inspection request line
417-4831
Owner responsible to adjust water meter setter, service line
and meter box to finish grade, maintain 6 inches of
clearance from bottom of meter box.lid.and top of meter.
Construct driveway to City Standards. Concrete with exposed
aggregate or other non-standard finishes(including colors or
dyes)are not allowed in the City road right of way. Broom
finish only. An inspection by Public Works Engineering is
required prior to pouring concrete. Public Works inspection
request line 417-4831
---- ------
Other Fees . . , . . . RES UNDERGRND SERVICE FEE 770.00
SEWER SYSTEM DELV CHARGE 2260.00
STATE SURCHARGE 4.50
PW WATER SYSTEM USE FEE 2260.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
Permit Fee Total 750.00 750.00 .00 00
Plan Check Total .00 .00 .00 .00
Other Fee Total 5294.50 5294.50 ,00 .00
Grand Total 6044.50 6044.50 .00 .00
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work as commenced,or if required inspections have not been requested within 180 days from the last
inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of
laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Signature of Contractor or Authorized Agent Date Signature of Owner(if owner is builder) Date
T:Forms/Building Division/Public Works Permit
0
PERMIT INSPECTION RECORD
CALL 417-4831 FOR UTILITY INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER,
INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INA CONSPICUOUS LOCATION.
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE
INSPECTION TYPE DATE ACCEPTED COMMENTS
YES NO
PW UTILITIES (Engineering Division)
WATERLINE/METER
SEWER CONNECTION
SANITARY
STORM
SITE DRAINAGE
SITE EROSION CONTROL
PARKING
SIDEWALK
CURB&GUTTER
DRIVEWAY APPROACH
BACK-FLOW DEVICE
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED
YES NO
CONSTRUCTION R.W./PW/ CONSTRUCTION-R.W.
ENGINEERING 417-4807 PW/ENGINEERING
FIRE 417-4653 FIRE DEPT.
PLANNING DEPT. 4174750 PLANNING DEPT.
BUILDING 417- BUILDING
4815
T:Forms/Building Division/Public Works Permit
c
THE
f 9 D
TY OF "V NGELES'; For City Use
P!
Permit#
43'-,L2
,L2
W A S H I N G T O N , U . S .
Date Received: /�- 4 13
321 East 51hStreet
Port Angeles, WA 98362 Date Approved
P: 360-417-4817 F: 360-417-4711
permits@cityofpa.us
Building Permit Application
Project Address:
106 FRi55Tl;�zL
Main Contact: Phone # 3(.0 - '177- 1,291
�00'r ams E-Mail: adam SS of t
Property Name Phone
Owner sAoy6
Mailing AddressEmail
P ox �5?7 AOOV&E
City State Zip
o r cews fin/ X362
Contractor Name Phone
l-�i�the yawles 253-8yo - 13 y9
Mailing Address Email
1130( 62? Ave. E 66osm4k j+;(,*Ae hentes . ",,K
City State Zip
'V YA II WA 9537 3
Contractor License # _ Expiration:
NI�iNHR$3+gD Ii - og- 2oi5
Project Value: Zoning: Tax Parcel # Lot#
$ � � ou
a
Type of Residential ® Commercial ❑ Industrial ❑ Public ❑
Permit Demolition ❑ Fire ❑ Repair ❑ Reroof(tear off/lay over) ❑
For the following, fill out both pages of permit application:
New Construction ® Remodel ❑ Addition ❑ Tenant Improvement ❑
Mechanical ❑ Plumbing ❑ Other ❑
Existing Fire Sprinkler System? Maximum height of structure Proposed Bedrooms Proposed Bathrooms
Yes ❑ No ❑ b It 2
Project S��
Description i
I have read and completed the application and know it to be true and correct.I am authorized to apply for this
permit. I understand that it is my responsibility to determine what permits are required and to obtain permits
prior to working on projects. I understand that the plan review fee is not refundable after plan review has
occurred. I understand that I will forfeit the review fee if I cancel or withdraw the application before the
permit is issued. I understand that if the permit is not issued within 180 days of receipt,the application will be
considered abandoned and the fees forfeit.
Date Print Name Signature
12/6113 SCOTr AWA57 q /�'�
Residential Structures
For Office Use
Area Description(SQ FT) Existing Proposed $$value
Basement
First Floor 21 12-
Second
2Second Floor
Covered Deck/Porch/Entry 94
Deck
Garage 52.1
Carport
Other(describe)
Area Totals
Commercial Structures
For Office Use
Area Descriptions (SQ FT) Existing Proposed $$Value
Existing Structure(s)
Proposed Addition
Tenant Improvement?
Other work(describe)
Area Totals
Lot/Site Coverage Calculations
Footprint(SQ FT) of all Structures:,.L Lot Size: %Lot Coverage
V, aSZ 1s.2
SQ FT Site coverage(all impervious+ %Site Coverage
structures) i.ar5ia �—� 3?y
Mechanical Fixtures
Indicate how many of each type of fixture to be installed or relocated as part of this project-
Air Handler Size: # Haz/Non-Haz Piping #of Outlets:
Appliance Vent # t Heater(Suspended,Floor,Recessed wall) # R
{ cwde
Boiler/CompressorSize: # Heating/Cooling appliance #
repair/alteration
Evaporative Cooler(attached,not # Pellet Stove/Wood-burning/Gas #
portable) Fireplace/Gas Stove Gas Cook Stove/Misc.
Fuel Gas Piping #of Outlets: Ventilation Fan,single duct #
Furnace/Heat Pump/ Size: # Ventilation System #
Forced Air Unit t
Plumbing Fixtures
Indicate how many of each type of fixture to be installed or relocated
Plumbing Traps # Fuel gas piping #of Outlets:
Water Heater # Medical gas piping #of Outlets:
Water Line # Vent piping #
Sewer Line # Industrial waste pretreatment #
interceptor
Other(describe):
T:\BUILDING\APPLICATION FORMS\BUILDING PERMIT 081212.DOCX
as s�
I ILS
I
i
i
1
i
\
2q \
X16'
l VeaJft
e,
ti apt
LNC-
�R���Ty
N
P4 Fol l m:rL
Lo-`olo
li
22,-0, 6'-32 24'-52 7' -9" 13,-6, m E
°m
FRAME BOTH WALLS AT 42" 5'-31" '
1 2 6'-6" 7'-0"
5'-9 E
2 AND CAP Wl2 LAVERS OF 7/s
A O.S.B.FOR PLANT SHELF. 2'-92
6'-0' F
60 610 S.G.D. 303 IIHS j R
S.G. 40 36 HS $.G. 60JHS R g
r , 5'SOAK. 8
yl; —'DW S °fBNOTE:SOLID BLOCKRANGE W/ { ALL THREE SIDES OFNING Hoop(vTQ) STIR. o THE SOAKING TUB
® BAT AT 21"D.C.
SOLID CORE 1%"MIN. ULTED NW/WEATHERSTRIP b6��I_A
EN' �., .N
mDSURFACE WARM WALL W/Yz 4'-0' �F4 MSTR.BDRM.G.W.B.ALL GARAGE WALU m 7 -IN CEILING SEPARATIONS. q'2-
81S Rv4 L4LHALF- 2 U) ¢<o
PLAINT SHELF 1 s w U)a
VAULT LINE 8'-31• 5'-9-• 3'-11' U.1 vl m
_._. .__.— .__..._ _..._ ...._-.._ ..__. .._.__. _2-m—11. 2 10" 2 2O4 ^�
WHOLE HOUSE FAN WI 06 Q J W n
n
GARAGE TIMER SWITCH AND O rP u ® O WIC ATTl_ M Q��o
VENTED WINDOWS IN _�, — AGC_`f __ ;w _
QN Z
HABITABLE ROOMS. LAUND.&DRY a RBS r...
IRC§M1507.3.4 IVT ® � O
O 16'x 7'OHD(MTL.NON-INSUL.) GREAT `? FURRED 2'7" '� O R g� Q C) O
2x6 WALL W
3'-0" 16'-0" 3'-0"
ROOM 16-' 1N So 4 a
a,�. N
2 4o v4 O O 2 6._9. Eo
IN
4 ENT ~_ BAT BDRM.4 =
a 3o Cn rn " a
60 50 HS 20 5 FIXG. am
IN
A u' N
3-52" 1t, LL
A2
O 2s O Z
. Q
10'-5• 4'-9" IN 0 J
2'_7• 'a J a
24'-0^ c LL
BDRM 2 BDRM 3
i+1 lV
I O
5050 HS so So H5 HILINE HOMES
11306 62ND AVENUE
AREA SUMMARY T-6" s-9 T-3" T-6^ (253)70-2244..t,129
MAIN FLOOR AREA 2112 SQ.FT. 13-3• A 14'-9-
PORCH 96 SQ.FT. 28'-0• PLAN: 2112
GARAGE 528 SQ.FT. DATE: 10/30/13
=HOSE BIB JOB#: 10105948
S.G. =SAFETY GLAZING
FLOOR PLAN Al
Prescriptive Energy Code Compliance for Climate Zones 6, 5 and Marine 4
t Projec!Information Contact Information
Adams project HLH #2112 HiLine Homes
Lot 22 Forest Trail Drive 253-840-1849
Port Angeles, WA
This project will use the requirements of the Prescriptive Path below and incorporate the
the minimum values listed. In addition, based on the size of the structure,the appropriate
number of additional credits are checked as chosen by the permit applicant.
Authorized Representative Date
Climate Zone 5 & Marine 4 6
R-Valuea U-Factora R-Valuea U-Factor'
Fenestration U-Factorb n/a 0.30 n/a 0.30
Skylight U-Factor n/a 0.50 n/a 0.50
Glazed Fenestration SHG Cb,e n/a n/a n/a n/a
Ceiling 44 0.026 49 0.026
Wood Frame Wallg"" 21 int 0.056 21+5ci 0.044
Mass Wall R-Value' 21/21h 0.056 21+5h 0.044
Floor 309 0.029 309 0.029
Below Grade Wal,,k 10/15/21 int+TB 0.042 10/15/21 int+TB 0.042
Slabd R-Value& Depth 10,2 ft n/a 10,4 ft n/a
*Table R402.1.1 and Table R402.1.3 Footnotes included on Page 2.
Each dwelling unit in one and two-family dwellings and townhouses, as defined in Section 101.2 of the
International Residential Code shall comply with sufficient options from Table R406.2 so as to achieve the
following minimum number of credits:
M1.Small Dwelling Unit: 0.5 points
Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration
area. Additions to existing building that are less than 750 square feet of heated floor area.
n2.Medium Dwelling Unit: 1.5 points
All dwelling units that are not included in#1 or#3, including additions over 750 square feet.
❑3. Large Dwelling Unit: 2.5 points
Dwelling units exceeding 5000 square feet of conditioned floor area.
Table R406.2 Summary
Option Description Credit(s)
1a JEfficient Building Envelope 1a 0.5
1 b Efficient Building Envelope 1b 1.0
1c Efficient Building Envelope 1c 2.0
2a Air Leakage Control and Efficient Ventilation 2a 0.5
2b Air Leakage Control and Efficient Ventilation 2b 1.0
2c Air Leakage Control and Efficient Ventilation 2c 1.5 El
3a High Efficiency HVAC 3a 0.5
3b High Efficiency HVAC 3b 1.0
3c High Efficiency HVAC 3c 2.0
3d High Efficiency HVAC 3d 1.0
4 High Efficiency HVAC Distribution System 1.0
5a Efficient Water Heating 0.5
5b Efficient Water Heating 1.5 , 1.5
6 Renewable Electric Energy 0.5 *1200❑kwh 0.0
Total Credits 1.50
*Please refer to Table R406.2 for complete option descriptions
http://www.energy.wsu.edu/Documents/2012/o20Res/o20Energy.pdf
Table R402.1.1 Footnotes
For SI: 1 foot .= 304.8 mm, ci .= continuous insulation, int .= intermediate framing.
a R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity which is
less than the label or design thickness of the insulation, the compressed R-value of the insulation from
Appendix Table A101.4 shall not be less than the R-value specified in the table.
b The fenestration U-factor column excludes skylights.The SHGC column applies to all glazed fenestration.
Exception: Skylights may be excluded from glazed fenestration SHGC requirements in Climate Zones 1
through 3 where the SHGC for such skylights does not exceed 0.30.
`1110/15/21.+TB" means R-10 continuous insulation on the exterior of the wall, or R-15 on the continuous
insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the
basement wall at the interior of the basement wall. "10/15/21.+TB" shall be permitted to be met with R-13
cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or
exterior of the wall. "10/13" means R-10 continuous insulation on the interior or exterior of the home or R-
13 cavity insulation at the interior of the basement wall. "TB" means thermal break between floor slab and
basement wall.
d R-10 continuous insulation is required under heated slab on grade floors. See R402.2.9.1.
e There are no SHGC requirements in the Marine Zone.
f Basement wall insulation is not required in warm-humid locations as defined by Figure R301.1 and Table
R301.1.
g Reserved.
h First value is cavity insulation, second is continuous insulation or insulated siding, so "13.+5" means R-13
cavity insulation plus R-5 continuous insulation or insulated siding. If structural sheathing covers 40 percent
or less of the exterior, continuous insulation R-value shall be permitted to be reduced by no more than R-3 in
the locations where structural sheathing is used to maintain a consistent total sheathing thickness.
The second R-value applies when more than half the insulation is on the interior of the mass wall.
For single rafter-or joist-vaulted ceilings,the insulation may be reduced to R-38.
k Int. (intermediate framing) denotes standard framing 16 inches on center with headers insulated with a
minimum of R-10 insulation.
Log and solid timber walls with a minimum average thickness of 3.5 inches are exempt from this insulation
requirement.
Table R402.1.3 Footnote
a Nonfenestration U-factors shall be obtained from measurement, calculation or an approved source or as
specified in Section R402.1.3.
r
Simple Heating System Size: Washington State
This heating system sizing calculator is based on the Prescriptive Requirements of the 2012 Washington State Energy Code(WSEC)and ACCA
Manuals J and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling
loads.
The glazing(window)and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of
0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2012 WSEC.
Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section,
some values will be calculated for you. If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension
Program at(360)956-2042 for assistance.
Project Information Contact Information
Adams project HLH#2112 HiLine Homes
Lot 22 Forest Trail Drive 253-840-1849
Port Angeles,WA
Heating System Type: O Forced Air Furnace O Heat Pump
To see detailed instructions for each section,place your cursor on the word"Instructions"
Design Temperature
Instructions f
Port Angeles �� Design Temperature Difference(AT) 42
AT=Indoor(70 degrees)-Outdoor Design Temp
Area of Building
Conditioned Floor Area
Instructions Conditioned Floor Area(sq ft) 2,112
Average Ceiling Height Conditioned Volume
Instructions Average Ceiling Height(ft) 8.0 16,896
Glazing and Doors U-Factor X Area = UA
Instructions 0.30 270 81.00
Insulation
Attic U-Factor X Area = UA
Instructions R 49 I. 0.026 2,112 54.91
Single Rafter or Joist Vaulted Ceilings U-Factor Area UA
Instructions Select R-Value E. + No selection
Above Grade Walls(see Figure 1) � U-Factor Area UA
Instructions 0.056 1,330 74.48
FloorsU-Factor Area UA
Instructions 0.029 2,112 61.25
Below Grade Walls(see Figure 1) _ U-Factor Area UA
Instructions , Select R-value f '..- No selection ---
Slab Below Grade see Figure 1) F-Factor Length UA
Instructions Select No selection SelectconditioningI� :,, ---
Slab on Grade(see Figure 1) F-Factor Length UA
Instructions ^� No selection
Select R-Value
-
:l - _
lLll
Location of Ducts
Instructions - Duct Leakage Coefficient
Unconditioned Space S
1.10
Sum of UA 271.64
Envelope Heat Load 11,409 Btu/Hour
Figure 1. Sum of UA XAT
Air Leakage Heat Load 7,664 Btu/Hour
Volume 0.6XATX.018
Above Grade Building Design Heat Load 19,073 Btu/Hour
Air Leakage+Envelope Heat Loss
Below Graile�
Building and Duct Heat Load 20,980 Btu/Hour
` Ducts in unconditioned space:Sum of Building Heat Loss X 1.10
Ducts in conditioned space:Sum of Building Heat Loss X 1
Maximum Heat Equipment Output 29,372 Btu/Hour
Building and Duct Heat Loss X 1.40 for Forced Air Furnace
Building and Duct Heat Loss X 1.25 for Heat Pump
(07/01/13)
Glazing Schedule
Project Information Contact Information
Scott& Melissa Adams project HLH#2112 HiLine Homes
Lot 22 Forest Trail Drive 253-840-1849
Port Angeles, WA
R402.3.3 Exception (15 sq.ft. max.)0
Vertical Glazing (Windows and glazed doors)
Plan Component Glazing Width Height Glazing
ID Description Ref. U-factor Qt. Feet Inch Feet Inch Area. UA
Great Room 0.30 1 4 5 20.01 6.00
Great Room 0.30 1 8 5 40.0 12.00
Entry 0.30 1 2 5 10.0 3.00
Bed 2 - 3 0.30 2 5 5 50.0 15.00
Bed 4 0.30 1 6 4 24.0 7.20
Master Bedroom 0.30 1 6 4 24.0 7.20
Master Bath 0.30 1 3 3 9.0 2.70
Kitchen 0.30 1 4 3 6 14.0 4.20
Dining Room SGD 0.30 1 6 6 10 41.0 12.30
0.01. 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.01 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.01 0.00
.0.0 . 0.00
0.0 0.00
0.0 .0.00
0.0 0.00
0:0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
6-61 0.00
6.61 o.00
Sum of Area and UA 1 232.01 69.60
Area Weighted U= UA/Area 1 0.30
BUILDING PERMIT INFORMATION
PLAN#2112
HIL NE CREATIVE DESIGN BUILDERS DBA: HiLINE HOMES
Ho nn e s 11306 62ND AVE E PUYALLUP,WA 98373 (253)840-1849
HILINH983*BD LICENSE EXPIRATION 11/08/2015
UBI#601-584-067
This will be a New Single Family Residence
Type of work: NEW HOME CONSTRUCTION-WOOD FRAME
NEW HOME AREA SUMMARY:
MAIN/1ST 2112 #of stories 1 SINKS 5
SECOND Bedrooms 4 TOILETS 2
TOTAL 2112 Bathrooms 2 TUBS 1
GARAGE(attached) 528 Porch 96 ft2 SHOWERS 2
ELECTRICAL
GREEN LINE ELECTRIC Shelton,WA(360-265-4962) GREENLE882PU(11-02-2014)
STANDARD Kw range 7.5 Kw HOUSE FAN SPECS: BROAN
dryer 5.0 Kw HOUSE: QTRE110 CFM:110
w/h 4.0 Kw BATH: 162 CFM:70
HVAC
no HVAC
CADET: 1500 WATTS PER UNIT
PLUMBING
KITSAP PLUMBERS GROUP Bremerton,WA(360-373-2859)KITSAPGO09CM(3-11-2015)
HEAT PUMP WATER HEATER
AIRGENERATE:AirTap HYBRID AT150
INSULATION
UNDERFLOOR: R30
ATTIC: R49
EXTERIOR WALLS: R23
WINDOW U-VALUE: .30
JURISDICTIONAL INFORMATION
CITY OF PORT ANGELES:321 EAST 5TH STREET PORT ANGELES, WA 98362
(360)417-4817 permits@cityofpa.us
(360)417-4711(fax)
TheEfficienMost Ener 9►Yt
......................................................._........................................ Water Heating System
Hot water used for bathing and laundry accounts
for nearly 25% of your home's energy bill. An
energy efficient water heating system can save you
hundreds of dollars each year. The AirTap Hybrid
next generation of water heaters run on a fraction of -—
. ..._-:......
the energy used by traditional water heating __-
systems such as electric, gas or tankless so that
every bath, shower or laundry costs significantly ;.
less.
Our ENERGY STAR®certified water heaters use f
advanced heat pump technology to extract heat :e.� y -
from ambient air to provide hot water
super-efficiently. Back-up resistance element
ensures that households don't run out of hot water
even when hot water demand is high. The AirTap
Hybrid ATI66 model is the only water heater that
meets Northern Climate Specification's stringent
Tier 2 criteria by providing high levels of energy
performance in cooler, northern climates.
UPGRADE product features:
YourElectric Water ..................................................................................................
Heater _ »High efficiency even in cold climate environment
Save Energy ;"` »Heat Pump rated at 9,000 BTU
& Money
>,Supplemental heating from 4kW resistance element
AirTap Hybrid water pp g
heaters use 70%*less »Heats water up to 135°F
energy compared to
standard electric water »Stainless Steel 304 construction (inside and out)
heaters. »Easy to use control panel with multiple operation modes:
- Econ (Heat pump only)
Experience a More -Auto (Heat pump and resistance element)
Comfortable Home - Heater(Resistance element only)
AirTap Hybrid operates at »Available in 66 and 80 gallon versions
a 48 decibel sound level,
similar to a new quiet-run - »6" top exhaust duct (double vent version with air intake
dishwasher. — ducting option also available)
Rebates & Tax »10-year limited warranty(lifetime warranty on tank)
Credits Available - »Intelligent controls and error management
Multiple rebates and tax »Emergency back-up heating system
credits available.For more
information contact your
local sales representative. 'LRGYS *men Wate,"R.ICAna'ys 2X2,
ergy Consumpivns in Therm unRs are cmvertetl to KWH.
Anlap Hyb dl ,2.40 Energy Factor(EF)as per EnergyStar.The energy consumption of Airiap is atljustM eccoNingty
r
save over$300 yearly*
..................................................................................................
A 4W • • •
AirTap Hybrid EMEpG�GUIDE
water heater
The energy guide compares the
average annual operation cost
;183 of AirTap Hybrid with a standard
w.....
t' „_ � electric water heater.
—1830— The AirTap Hybrid water heater
will cost$183 yearly to operate 1
compared to$486 earl for a
P yearly
s486 standard electric water heater.' ,
Standard 1
?,,m electric
IF.--4-8—,-5 w
water heater
1
calculate your Payback.
•
1
AirTap"Hybrid
Standard electric water heater price -
Incentives&Rebates
Price after deductions
1
Yearly savings - 303 1
Payback
/ s
'ENEiGYSTAR°°Res idenWWater Heate Final CN—Analysis200$
En qy Consumptions in Therm units are converted to KWH,
AirTap Hybrid has 2.40 Ernrgy Factor(EF)as per EnergyStar.The a aergycansompf-of Air lap is adjusted a=,d,ngly
"Estimated Payback
air enerate.
�AdapH—Energy S.10-
8500 Commerce Park Drive,Suite 105
Houston,TX 77036
Tel 1.713.574.6729 1 Fax 1.281.520.3987 MEETS Northern Climate Efficiency
S MET
www.airgenerate.com Pecs Tier 2 Ally
: .
f,
1201 1305 ,
� n t sir
r p r 1313
AL
Forest Trail
1310
,
1203
h
t�yy , ./1•� x L •
1205 �r 1307
M .a - • 1305 t
>r
•� a. 1303 'a
e� 1207
1301 s
.A ',. 1310
O
O
i.
... R0 o k
Or
A. Abrous, Ph.D., P.E. HiLine Homes Page 1 of 20
PLAN 211213 [30®PSF SNOW, 110 mph, Exp. C, & SDC D2]
PROJECT INFORMATION AND CRITERIA
1. PROJECT INFORMATION
OWNER/ADDRESS SCOTT & MELISSA ADAMS
SITE ADDRESS: LOT 22 PORT ANGELES, WA 98382
JOB NUMBER: 10105948
2. STRUCTURAL DESIGNER INFORMATION
ABDELOUAHAB ABROUS, Ph.D., P.E.
HiLine Homes
(p\FIA/1
Design & Engineering Department owo;.WAS/ -1
11306 62ND Ave E., Puyallup, WA 98373
Phone: (253) 770-2244 Ext. 132
Email: Wabrous(aD-HiLinehomes.com
1P 3611
ST
Washington License No: 36110 AL����
Oregon License No: 81419PE Note: The above stamp applies to the structural
members and assemblies described in the following
Idaho License No: P-14132 calculations only and is valid with a copied or wet
stamp intended for reuse by HiLine Homes.
3. SCOPE OF DESIGN
TYPE OF DESIGN LATERAL ENGINEERING ANALYSIS OF
WIND AND SEISMIC FORCES
EXTENT OF DESIGN Structural specifications
2012 International Building Code (IBC) for
Washington & 2010 Oregon Structural
Specialy Code (OSSC) for Oregon
2012 International Residential Code (IRC)
for Washington & 2011 Oregon Residential
Specialy Code (ORSC) for Oregon
REFERENCE CODES AND STANDARDS 2005 National Design Specification (NDS)
American Society of Civil Engineers
(ASCE) Standard 7-10
American Society for Testing Materials
(ASTM) Standard A307
Special Design Provisions for Wind and
Seismic (2008 Edition
Revised PROJECT INFORMATION AND DESIGN CRITERIA Printed
11/1/2013 Plan 2112-13 30-PSF Snow, 110 mph, Exp C, & SDC D2—ADAMS 11/13/2013
A. Abrous, Ph.D., P.E. HiLine Homes Page 2 of 20
4. DESIGN CRITERIA
GROUND SNOW LOAD: pg = 30-psf
FLAT ROOF SNOW LOAD PER ASCE 7-10(LIVE LOAD): pf = 21.0-psf
MINIMUM ROOF SNOW LOAD PER COUNTY: pf = 25.0-psf
ADOPTED FLAT ROOF SNOW LOAD (LIVE LOAD): pf = 25.0-psf
ROOF DEAD LOAD: Droof = 15-psf
EXTERIOR WALL DEAD LOAD: Dwa11 = 15-psf
INTERIOR WALL DEAD LOAD: Dwall = 10-psf
SEISMIC DESIGN CATEGORY: SDC D2
BASIC WIND SPEED: 110-mph
ASCE 7-10 ULTIMATE DESIGN WIND SPEED: 140-mph
WIND EXPOSURE FACTOR: C
ALLOWABLE SOIL PRESSURE: 1,500-psf
Framing Material: No. 2 Hem-Fir minimum.
Wood Structural Panels: APA Rated.
10d Nails Diameter: 0.148-in
MATERIAL SPECIFICATIONS:
8d Nails Diameter: 0.131-in
Concrete Strength @ 28-days: 2,500-psi
Anchor Bolts: ASTM A307 Steel
CONTENTS
Project Information and Criteria Page 1
Description Page 3
Specifications and Design Criteria Page 3
Engineering Calculations Page 3
LIST OF TABLES
Table A. Structural Specifications and Allowable Loads Page 5
Table B. Building Data Page 9
Table C. Wind Design Criteria Page 10
Table D. Seismic Design Criteria Page 11
Table E-1. Wind Loads (House) Page 12
Table E-2. Wind Loads (Garage) Page 13
Table F-1. Minimum Wind Loads (House) Page 14
Table F-2. Minimum Wind Loads (Garage) Page 15
Table G. Seismic Loads Page 16
Table H. Controlling Shear Loads Page 17
Table I. Wind Shear Wall Loads Page 18
Table J. Seismic Shear Wall Loads Page 19
Table K. Roof Diaphragm Load Calculations Page 20
Revised PROJECT INFORMATION AND DESIGN CRITERIA Printed
11/1/2013 Plan 2112-13 30-PSF Snow, 110 mph, Exp C, & SDC D2_ADAMS 11/13/2013
A. Abrous, Ph.D., P.E. HiLine Homes Page 3 of 20
DESCRIPTION
This report provides engineering calculations and structural design specifications for HiLine Homes
Plan 2112. This one-story house is 2112-sf in area plus an optional two-car garage. Design
specifications are provided in Table A, building data are given in Table B, and wind and seismic criteria,
including calculations, are included in Tables C and D, respectively. Lateral engineering calculations
are provided in Tables E through K. Calculations are performed using Microsoft Excel worksheets.
SPECIFICATIONS AND DESIGN CRITERIA
Structural specifications and design criteria are provided in Tables A, B, C, and D as discussed in the
following paragraphs.
Table A. Specifications of Structural Components and Fasteners
Specifications are provided for size and spacing of anchors bolts, shear wall hold-downs,
shear wall sheathing and nailing, shear transfer, and roof framing. Structural specifications
are identified with respect to Wall Lines, which are shown on Plan Sheet S2.
Table B. Building Data
The building geometrical dimensions are specified, including lengths of exterior walls, and
interior partitions for the transverse and longitudinal directions. The maximum ground snow
load is Pg of 30-psf.
Table C. Wind Design Criteria
ASCE Standard 7-10, Section 28.5, "Enclosed Simple Diaphragm Low-Rise Building"
method is used for determining wind loads. Wind design criteria are based on a 110-mph
basic wind speed and Building Height and Exposure Factor (A) C. Overturning moments
due to wind forces are less than allowable restorative dead load moments as shown in
Table G. Uplift loads for roof tributaries are calculated assuming the maximum uplift for
wind Zone E or F applies to the tributary area.
Table D. Seismic Design Criteria
Seismic design loads are based on Site Class D soils per ASCE Standard 7-10, Section
11.4.2 and Table 20.3-1 for stiff soils. The Equivalent Lateral Force Procedure of the
American Society of Civil Engineers (ASCE) Standard 7-10, Section 12.8 is used for
calculating seismic forces.
ENGINEERING CALCULATIONS
Engineering calculations are documented in Tables E through K based on specifications in Tables B, C,
and D. These tables provide the following information:
Table E. Wind Loads
Wind loads and overturning moments are calculated in Table E for two orthogonal
directions, transverse and longitudinal. Calculated values are linked to Table H, Controlling
Shear Loads to determine if wind, minimum wind, or seismic loads control design of lateral
restraint. Unit uplift on the building is also calculated for both the transverse and
longitudinal directions. Overturning loads due to design base winds are calculated with a
link to Table G, Seismic Loads where they are compared to seismic and building restoring
Table F. Minimum Wind
Revised PROJECT INFORMATION AND DESIGN CRITERIA Printed
11/1/2013 Plan 2112-13 30-PSF Snow, 110 mph, Exp C, & SDC D2—ADAMS 11/13/2013
A. Abrous, Ph.D., P.E. HiLine Homes Page 4 of 20
Minimum wind loads are provided in Table F based on horizontal pressures equal to 16-psf
for zones A and C, 8-psf for zones B and D, and vertical pressures equal to zero per ASCE
7-10, Section 28.6.4. Calculations are performed for both transverse and longitudinal
directions and linked to Table H for comparison to wind and seismic loads.
Table G. Seismic Loads
Table G provides seismic shear loads based on seismic design criteria in Table D.
Calculations are based on seismic design criteria in Table D and the Lateral Force
Procedure method of ASCE Standard 7-10, Section 12.8. This procedure is valid for Risk
Category I or II buildings of light frame construction not exceeding three stories in height for
SDC D and higher per ASCE 7-10, Table 12.6.1. Seismic loads are calculated for
transverse and longitudinal directions. Overturning moments are calculated in the table and
compared to allowable restoring dead load moments. The building is stable with respect to
overturning.
Table H. Controlling Shear Loads
Table H provides a summary of seismic shear loads. Shear load values from Tables E, F,
and G are compared to determine controlling lateral forces. The controlling values are
linked to Tables I and K for calculating maximum shear wall loads for wind and seismic
forces, respectively.
Table 1. Wind Shear Loads
Table H provides transverse and longitudinal loads on the building structure including wall
length, applied unit shear, shear wall length, resistive unit shear, unit dead load on shear
walls, and hold-down loads for the various shear wall lengths based on controlling wind
shear loads from Table H. Shear wall hold-downs are calculated based on wind and dead
load combinations using the allowable stress design method per ASCE Standard 7-10,
Section 2.4.
Table J. Seismic Shear Loads
Table J provides transverse and longitudinal loads on the building structure including wall
length, applied unit shear, shear wall length, resistive unit shear, unit dead load on shear
walls, and hold-down loads for the various shear wall lengths based on seismic shear loads
from Table H. Shear wall hold-down loads are calculated based on wind and dead load
combinations using the allowable stress design method per ASCE Standard 7-10, Section
2.4.
Table K. Roof Diaphragm Calculations
Table H provides roof diaphragm load calculations for determining diaphragm shear for
seismic loads and comparing these loads with wind and minimum wind loads from Table H.
Shear wall and roof diaphragm deflections are calculated to confirm that the diaphragm is
flexible as allowed by ASCE Standard 7, Section 12.3.1.1. Strength level seismic unit shear
values are used to calculate deflections. Calculations are based on American Plywood
Association (APA) Report T2002-17, Estimating Wood Structural Panel Diaphragm and
Shear Wall Deflection, April 17, 2002. Uplift due to design base wind loads are calculated
assuming that the roof experiences a maximum uplift pressure from wind zone E or Zone F.
Allowable roof dead loads plus truss connections exceed uplift by an acceptable margin.
Revised PROJECT INFORMATION AND DESIGN CRITERIA Printed
11/1/2013 Plan 2112-13 30-PSF Snow, 110 mph, Exp C, & SDC D2_ADAMS 11/13/2013
A. Abrous, Ph.D., P.E. HiLine Homes Page 5 of 20
TABLE A. STRUCTURAL SPECIFICATIONS AND ALLOWABLE LOADS
THIS TABLE PROVIDES SUMMARY STRUCTURAL SPECIFICATIONS. ADDITIONAL DETAILS FOR STANDARD
SPECIFICATIONS AND CALCULATION OF ALLOWABLE LOADS ARE PROVIDED AT THE END OF THIS TABLE.
EXPLANATION OF WALL LINES
Shear walls and structural specifications are identified with Wall Lines on plan Sheet S2. Lettered Wall Lines are
generally identified from the front to the rear of the building and Numbered Wall Lines start at the left and continue to
the right (STANDARD PLAN). For reversed plans, Lettered Wall Lines remain the same and the Numbered Wall Lines
start at the right of the plan (REVERSED PLAN).
STRUCTURAL SPECIFICATIONS
FOUNDATION ANCHORINGsSPECIFICATIONS (ALL,WALL LINES) * .t3
Maximum Applied Shear per Tables I or J (lb) 4,236
Wall length under maximum applied shear per Tables I or J (ft) 32
Minimum number of anchor bolts when installed at 72-in o.c. minimum 2 anchors/mudsill 6
Maximum anchor bolt Load @ 72-in o.c. minimum 2 anchors per mudsill (lb) 669
Basic allowable single shear for fastening 1.5-in Hem-Fir framing to concrete with 1/2-in dia. ASTM A307
bolts with minimum 7-in embedment = 590-Ib per 2005 NDS Table 11E. Adjustment for 10-minute 944
wind/seismic loads = 1.6 per 2005 NDS Table 2.3.2. Allowable shear load = (1.6)(590)= 944-Ib.
Install 1/2-in dia. ASTM A307 anchor bolts @ 72-in o.c., minimum 7-in embedment in concrete and maximum 12-
in from end of mudsills with minimum 2 anchors per mudsill.
SHEAR , ALL,HOLD-DOWN SPECIFICATIONS
Wall Line C (Standard Garage Door Location)
Maximum overturning tension due to wind load per Table I (lb) 1,132
Maximum overturning tension due to seismic load per Table J (lb) 801
Allowable wind Tension Load for Simpson STHD10 Strap Ties at endwall location is 1,705-Ib 1,705
Allowable seismic Tension Load for Simpson STHD10 Strap Ties at endwall location is 1,435-Ib 1,435
At both ends of each garage portal, install Simpson STHD10 Strap Tie Holdowns per manufacturer's
instructions as shown on the plan. Fasten to minimum 3-in framing. (total of 4 STHD10s).
Wall Line. 2 (Perforated Shear Wall Analysis)
Maximum overturning tension due to wind load per Table I (lb) 996
Maximum overturning tension due to seismic load per Table J (lb) 1,348
Maximum wind shear(V) per Tables I or J (lb). 3,289
Maximum seismic shear(V) per Tables I or J (lb). 4,236
Shear Wall Clear Height(ft) 7.8
Maximum Opening Height (ft) 6.8
Percentage of Full-Height sheathing (%) 87.0
Ratio of Maximum Opening Height to Wall Clear Height 0.88
Shear Resistance Adjustment Factor(Co) per 2008 SDPWS Table 4.3.3.5 0.85
Sum of Perforated Shear Wall Segment Lengths (ft) 21
Design wind Shear Capacity of Wall -6-in edge nailing (lb) 6,515
Design seismic Shear Capacity of Wall - 6-in edge nailing (lb) 4,641
CHECK IF SHEAR CAPACITY OF PERFORATED SHEAR WALL IS ADEQUATE YES
Hold-Down Wind Tension Load, T=Vh/CO7-Li (lb) 1,437
Effective Wind Shear, v=V/COZLi (Ib/ft) 184
Hold-Down Seismic Tension Load, T = Vh/CO7-Li (lb) 1,851
Revised STRUCTURAL SPECIFICATIONS AND ALLOWABLE LOADS Printed
11/1/2013 Plan 2112-13 30-PSF Snow, 110 mph, Exp C, & SDC D2_ADAMS 11/13/2013
A. Abrous, Ph.D., P.E. HiLine Homes Page 6 of 20
TABLE A. STRUCTURAL SPECIFICATIONS AND ALLOWABLE LOADS
Effective Seismic Shear, v=V/CO7_Li (Ib/ft) 1 237
Allowable Wind Tension Load for Simpson STHD10 Strap Ties at corner location is 3,140-Ib 3,140
Allowable Seismic Tension Load for Simpson STHD10 Strap Ties at corner location is 2,640-Ib 2,640
At both ends of the wall line, install Simpson STHD10 Strap Tie Holdowns at each corner per manufacturer's
instructions as shown on the plan. Fasten to minimum 3-in framing with 24-16d sinker nails (total of 2
STHD10s). Apply 7/16-in. OSB wood structural panels to Hem-Fir framing members with 8d nails @ 6-in o.c. on
panel edges, 12-in o.c. in the field, and all edges blocked.
SHEAR WALL-SHEATHING"SPECLFICATIONS 4 F t
All Wall Lines
Maximum resistive unit wind shear load per Table I (Ib/ft) 157
Maximum resistive unit seismic shear load per Table J (Ib/ft) 114
Basic allowable shear for wind loads = 785-lb/ft per SPECIAL DESIGN PROVISIONS FOR WIND AND
SEISMIC Table 4.3A for 8d nails @ 6-in o.c. on edges., 12-in o.c. in the field, &framing @ 16-in o.c. per note 365
2. Adjustments 0.50 for ASD and 0.93 for Hem-Fir framing. Allowable shear= (0.50)(0.93)(785) = 365-lb/ft.
Basic allowable shear for seismic loads = 560-Ib/ft per SPECIAL DESIGN PROVISIONS FOR WIND AND
SEISMIC Table 4.3A for 8d nails staggered @ 6-in o.c. on edges, 12-in o.c. in the field &framing @ 16-in o.c. 260
per Note 2. Adjustments are 0.50 for ASD and 0.93 for Hem-Fir framing. Allowable shear = (0.50)(0.93)(560)
=260-lb/ft.
Apply 7/16-in. OSB wood structural panels to Hem-Fir framing members with 8d nails @ 6-in o.c. per standard
specification.
SHEAR TRANSFER=S.PECIFICATIONS-` - z
All Wall Lines
Fasten double top plates together with 10d nails @ 12-in o.c. and 6-in o.c. at splices. Overlap splices 4-ft.
minimum. Fasten OSB wall sheathing between shear wall segments at same fastener spacing as on shear
walls.
Fasten OSB panels to mudsills with minimum 8d nails @ 6-in o.c.
Wall Lines A, 1, 2, & 4 (Gables)
Maximum applied unit wind shear per Table I (Ib/ft) 103
Maximum applied unit seismic shear per Table J (Ib/ft) 132
Basic allowable single shear for 10d common toenails with 1.5-in thickness Hem-Fir side members =
(0.83)(102)=84-Ib per NDS Table 11 N. Adjustment for 10-minute wind/seismic loads = 1.6. Allowable shear 135
load = (1.6)(0.83)(102) = 135-Ib.
Allowable load for 2-10d common toenails @ 16-in o.c. = (0.83)(2)(12/16)(1.6)(102) = 203-Ib/ft. 203
Maximum Allowable Seismic Unit Shear seismic loads = 150-Ib/ft per SDPWS Section 4.1.7 150
Fasten gable-end trusses to double top plates with 2-10d toenails @ 16-in o.c. or 1-10d toenail @ 8-in o.c.
Wall Lines B, C, & D (Eaves)
Maximum applied unit wind shear per Table I (lb) 50
Maximum applied unit seismic shear per Table J (Ib/ft) 38
See Roof Framing Specification for truss connections and blocking.
Fasten per Roof Framing Specification for truss connections and blocking. 381
ROOF DIA,.HRAGlWgF AMING`SPECIFICATIONS
Roof Sheathing
Revised STRUCTURAL SPECIFICATIONS AND ALLOWABLE LOADS Printed
11/1/2013 Plan 2112-13 30-PSF Snow, 110 mph, Exp C, & SDC D2_ADAMS 11/13/2013
A. Abrous, Ph.D., P.E. HiLine Homes Page 7 of 20
TABLE A. STRUCTURAL SPECIFICATIONS AND ALLOWABLE LOADS
Maximum applied unit wind shear per Table I (Ib/ft) 103
Maximum applied unit seismic shear per Table J (Ib/ft) 132
Basic allowable unit shear for wind/seismic loads = 645/460-Ib/ft per 2008 SDPWS Table 4.2C for 7/16-in
unblocked panel diaphragms. Adjustment Factor (AF) for ASD = 0.5. Adjusted allowable unit shear = 323/230
(0.50)(645/460) = 323230-Ib/ft.
Allowable snow (live) load for 7/16-in APA Span Rated 32/16 with supports @ 24-in o.c. per APA Table 25 = 40
40-psf
Allowable snow (live) load for 15/32-in APA Span Rated 24/16 with supports @ 24-in o.c. per APA Table 25 = 70
70-psf
Up to 40 psf ground snow load, install 7/16-in unblocked APA Span Rated 24116 (32/16) panels to engineered
trusses @ 24-in o.c. per IBC Case 1. Fasten with 8-d nails @ 6-in o.c. on supported edges and 12-in o.c. in the
field. Beyond 70 psf ground snow load, use See Truss Blocking & Boundary Nailing below for additional
requirements. Beyond 40 psf ground snow load, use 15/32-in panels instead. Beyond 70 psf ground snow load,
use 19/32-in sheathing.
Truss Blocking & Boundary Nailing
Fasten 2X4 vent blocking in each truss bay with 1-10d-toenail into truss, each side. Fasten roof diaphragm to
blocking with 8d nails @ 6-in o.c.
Truss Connections (Lateral Loads)
Maximum applied unit shear per Table H (Ib/ft) 88
Truss Connections (Longitudinal Loads)
Maximum applied unit shear per Tables I and J (Ib/ft) 65
Basic allowable single shear for 10d common toenails with 1.5-in thickness Hem-Fir side members =
(0.83)(102)=84-Ib per NDS Table 11 N. Adjustment for 10-minute wind/seismic loads = 1:6. Allowable shear 135
load = (1.6)(0.83)(102) = 135-Ib.
Allowable load for 2-10d common toenails = (0.83)(2)(1.6)(102) =271-lb/ft. 271
Simpson H2.5A/H1 Seismic & Hurricane Tie lateral load resistance F2 = 110/140-Ib 110/140
Simpson H2.5A/H1 Seismic& Hurricane Tie longitudinal load resistance F, = 110/415-Ib 110/415
Allowable load for 2-10d common toenails = (2)(0.83)(1.6)(102) = 271-Ib per truss end. Allowable load for
H2.5A or H1 Seismic& HurricaneTies = 110-Ib per truss end for Hem-Fir. Total allowable load per truss end = 381
271 + 110 = 381-lb per truss end = 381-lb (H2.5A ties control lateral loads).
Fasten truss tails to top plates with 2-10 toenails and a Simpson H2.5A or H1 Seismic & Hurricane Tie fastened
to truss and top plates per manufactures instructions. (see sheet S3, Roof Framing Plan).
Allowable load for Simpson RBC Clip @ 24-in o.c. =(12/24)*(380) = 190-Ib/ft. 190
Nail roof sheathing to blocking with 8d nails @ 6-in o.c. Fasten blocking to top plates with Simpson RBC clips
@ 24-in o.c. -fill all nail holes.
Truss Connections (Uplift Loads)
Maximum net uplift on truss connection for 85,mph, Exposure C per Table K(lb). -165
Maximum net uplift on truss connection for 95 mph, Exposure C per Table K (lb). -253
Maximum net uplift on truss connection for 110 mph, Exposure C per Table K (lb). -448
Allowable uplift for H2.5A/H1 Seismic & Hurricane Ties = 520/400-Ib for Hem-Fir framing. 520/400
Allowable uplift for H10 Seismic & Hurricane Ties =850-Ib for Hem-Fir framing. 850
Fasten truss tails to top plates with H2.5A or H1 Seismic & Hurricane Ties for 85-mph wind speeds. Use H10
Ties for higher speeds.
Truss Chord Splice Nailing
Revised STRUCTURAL SPECIFICATIONS AND ALLOWABLE LOADS Printed
11/1/2013 Plan 2112-13 30-PSF Snow, 110 mph, Exp C, & SDC D2_ADAMS 11/13/2013
A. Abrous, Ph.D., P.E. HiLine Homes Page 8 of 20
TABLE A. STRUCTURAL SPECIFICATIONS AND ALLOWABLE LOADS
Maximum applied chord tension load per Tables J, C =T = M/b =vrL2/b8(lb). 620
Allowable chord splice tension load for 10d nails @ 6-in o.c. 1,469
Fasten exterior wall top plate splices together with 10d nails @ 6-in o.c. Minimum splice length =48-in.
Revised STRUCTURAL SPECIFICATIONS AND ALLOWABLE LOADS Printed
11/1/2013 Plan 2112-13 30-PSF Snow, 110 mph, Exp C, & SDC D2—ADAMS 11/13/2013
A. Abrous, Ph.D., P.E. HiLine Homes Page 9 of 20
TABLE B. BUILDING DATA
Description Value Description Value
BUILDING DIMENSIONS BUILDING INERTIAL DATA
Transverse Width of Building (ft) 48.0 Roof Diaphragm Dead Load (psf) 15
Longitudinal Length of Building (ft) 52.0 Exterior Walls Dead Load (psf) 15
Partition Walls Dead Load (psf) 10
Roof Slope(5/12) 0.42
Length of Gable-End Roof Overhang (ft) 1.0 MEAN AND MAXIMUM BUILDING HEIGHTS
Length of Eave-End Roof Overhang (ft) 1.3 Roof Height(ft) 7.8
Maximum Truss Span (ft) 36.01 Mean Height(ft) 11.6
Maximum Height (ft) 15.3
MAIN FLOOR DIMENSIONS
Wall Height(ft) 7.8 CALCULATION OF LENGTH OF END ZONE, 2a
Transverse Exterior Walls Length (ft) 96.0 Least horizontal Building Dimension, b (ft) 48.0
Longitudinal Exterior Walls Length (ft) 104.0 0.4* Mean Building Height(ft) 4.62
Total Exterior Walls Length (ft) 200.0 0.1*b (ft) 4.8
Total Partitions Weight(Ib)-ASCE 7-10 12.7.,21,120 End Zone Dimension, a(ft) 4.6
Adjusted End Zone Dimension, a (ft) 4.6
Length of End Zone, 2a (ft) 9.2
BUILDING ENCLOSED AREA
Building Enclosed Area (sf) 2,112.0
Garage Enclosed Area (sf) 528.0
Building and Garage Enclosed Area (sf) 2,640.0
GARAGE DIMENSIONS GARAGE LENGTH OF END ZONE, 2a
Wall Height(ft) 7.8 Least horizontal Building Dimension, b (ft) 22.0
Transverse Width of Garage (ft) 24.0 0.4* Mean Building Height(ft) 4.12
Longitudinal Length of Garage (ft) 22.0 0.1*b (ft) 2.2
Transverse Exterior Walls Length (ft) 48.01 End Zone Dimension, a(ft) 2.2
Longitudinal Exterior Walls Length (ft) 44.0 Adjusted End Zone Dimension, a(ft) 3.0
Maximum Truss Span (ft) 24.0 Length of End Zone, 2a(ft) 6.0
Mean Height(ft) 10.3
Maximum Height(ft) 12.8
Total Exterior Walls Length (ft) 92.0
Total Partitions Weight(Ib)-ASCE 7-10 12.7. 0
SNOW DATA
Maximum Ground Snow Load, p9 (psf) Assumed 30.0
Exposure Factor, Ce ASCE 7-10 Table 7-2, for Exposure C 1.0
ermal Factor, Ct ASCE 7-10 Table 7-3, for Residences 1.0
Snow Importance Factor, IS ASCE 7-10 Table 1.5-2, for Category II 1.0
Slope Factor, Cs ASCE 7-10 Figure 7-2a 1.0
Flat Roof Snow Load, pf(psf) ASCE 7-10 Equation 7.3-1, pf= 0.7 Ce Ct IS p9 21.0
MINIMUM Flat Roof Snow Load, pf(psf) BUILDING DEPARTMENT 25.0
ADOPTED Flat Roof Snow Load, pf(psf) CONTROLLING VALUE 25.0
Note:
Transverse Width is measured perpendicular to the ridge line and longitudinal length parallel to the ridge line.
Revised BUILDING DATA Printed
11/1/2013 Plan 2112-13 30-PSF Snow, 110 mph, Exp C, & SDC D2-ADAMS 11/13/2013
A. Abrous, Ph.D., P.E. HiLine Homes Page 10 of 20
TABLE C. WIND DESIGN CRITERIA
Description Value Description Value
WIND DESIGN CRITERIA MAIN FLOOR
Basic Wind Speed Vas(mph) 110 TRANSVERSE BUILDING ZONE DATA
ASCE 7-10 Design Wind Speed (mph) 140 Horizontal Wind Force Loading
Wind Exposure Category ClTransverse Zones A& B Width (ft) 9.2
Simplified Procedure per ASCE 7-10 28.5 Yes Transverse Zones C & D Width (ft) 42.8
Exposure & Height Factor, A 1.21 Transverse Zones A&C Height (ft) 7.8
Topographical Factor, KZt 1.00 Transverse Zones B & D Height(ft) 7.5
Vertical Wind Force Loading
DESIGN WIND PRESSURES (psf) Transverse Roof Zones E & F Width (ft) 9.2
TRANSVERSE DIRECTION (CASE A) Transverse Roof Zones G & H Width (ft) 42.8
A- End Zone of Wall 40.9 Transverse Roof Zones E &F Length (ft) 24.0
B - End Zone of Roof -2.2 Transverse Roof Zones G & H Length (ft) 24.0
C - Interior Zone of Wall 28.41 1
D - Interior Zone of Roof 0.3 LONGITUDINAL BUILDING ZONE DATA
E- End Zone of Windward Roof -26.9 Horizontal Wind Force Loading
F - End Zone of Leeward Roof -24.8 Longitudinal Zone A Width (ft) 9.2
G - Interior Zone of Windward Roof -19.0 Longitudinal Zone C Width (ft) 38.8
H - Interior Zone of Leeward Roof -19.31 Longitudinal Zone A Height(ft) 9.7
Eo - End Zone of Windward OVHG Roof -41.9 Longitudinal Zone C Height (ft) 13.5
Go- Interior Zone of Windward OVGH Roof -33.9 Vertical Windforce Loading
LONGITUDINAL DIRECTION (CASE B) Longitudinal Roof Zones E & F Width (ft) 9.2
A- End Zone of Wall 31.1 Longitudinal Roof Zones G & H Width (ft) 38.8
B - End Zone of Roof -16.11 Longitudinal Roof Zones E &G Length (ft) 26.0
C - Interior Zone of Wall 20.6 Longitudinal Roof Zones F &H Length (ft) 26.0
D - Interior Zone of Roof -9.6
E- End Zone of Windward Roof -37.3
F - End Zone of Leeward Roof -21.2
G - Interior Zone of Windward Roof -26.0
H - Interior Zone of Leeward Roof -16.4
Eo- End Zone of Windward OVHG Roof -52.3
Go - Interior Zone of Windward OVGH Roof -40.9
GARAGE
TRANSVERSE BUILDING ZONE DATA
Horizontal Wind Force Loading
Transverse Zones A& B Width (ft) 6.0
Transverse Zones C & D Width (ft) 16.0
Transverse Zones A&C Height(ft) 7.8
Transverse Zones B &D Height(ft) 5.0
LONGITUDINAL BUILDING ZONE DATA
Horizontal Wind Force Loading
Longitudinal Zone A Width (ft) 6.0
Longitudinal Zone C Width (ft) 18.0
Longitudinal Zone A Height (ft) 9.1
Longitudinal Zone C Height(ft) 10.7
Note:
Transverse Width is measured perpendicular to the ridge line and longitudinal length parallel to the ridge line.
Revised WIND DESIGN CRITERIA Printed
11/1/2013 Plan 2112-13 30-PSF Snow, 110 mph, Exp C, & SDC D2 ADAMS 11/13/2013
A. Abrous, Ph.D., P.E. HiLine Homes Page 11 of 20
TABLE D. SEISMIC DESIGN CRITERIA
Description Reference/Calculation Value
SEISMIC GROUND MOTION VALUES AND SITE SPECIFICATIONS
Building Risk Category ASCE Standard 7-10, Table 1-5.1 II
Seismic Importance Factor, le ASCE Standard 7-10, Table 1.5-2 1.0
Default Seismic Site Classification ASCE Standard 7-10, Table 20.3-1 D
Seismic Design Category 2009 IRC Table R301.2.2.1.1 D2
Response Modification Coefficient, R ASCE Standard 7-10, Table 12.2-1 6.5
Building Period Parameter: Ct ASCE Standard 7-10, Table 12.8-2 0.02
Redundancy Factor, p ASCE Standard 7-10, Section 12.3.4.2 1.000
Site Short Period Design Acceleration, SDS (g) 2009 IRC Table R301.2.2.1.1, for SDC D2 1.170
Mapped MCE Long Period Acceleration, SM, (g) ASCE Standard 7-10, Figure 22-2 0.600
Ground Snow Load (psf) Building Department 30.0
Flat Roof Snow Load (psf) Calculation, See Table B 25.0
COMPUTATION OF DESIGN RESPONSE SPECTRUM DATA
Mean Building Height, h (ft) Per Plan (Calculated in Table B) 11.6
Building Period, Ta = Cth314(sec) ASCE Standard 7-10, Section 12.8.2.1 0.125
Site Long Design Period Acceleration, SD, (g) ASCE Standard 7-10, 11.4.4, SD, =2/3SM, 0.400
To=0.2*SD1/SDS (sec) ASCE Standard 7-10, Section 11.4.5 0.068
TS=SD,/SDS (sec) JASCE Standard 7-10, Section 11.4.5 0.342
COMPUTATION OF SEISMIC DESIGN COEFFICIENT
Seismic Design Coefficient: CS=SDS*le/R JASCE Standard 7-10, Section 12.8.1.1 0.180
Revised SEISMIC DESIGN CRITERIA Printed
11/1/2013 Plan 2112-13 30-PSF Snow, 110 mph, Exp C, & SDC D2—ADAMS 11/13/2013
A. Abrous, Ph.D., P.E. HiLine Homes Page 12 of 20
TABLE E-1. WIND LOADS (HOUSE)
Wind Zone Zone Zone Moment
Zone Pressure Width Ht./Leng. Zone Area Force Arm Moment
(Psf) (ft) (ft) (sf) (lb) (ft) (ft-Ib)
TRANSVERSE WIND LOADING
Horizontal Wind Loads
Transverse Wall Zone A 40.9 9.2 7.8 72.1 3,567 3.9 13,910
Transverse Roof Zone B 0.0 9.2 7.5 69.3 0 7.8 0
Transverse Wall Zone C 28.4 42.8 7.8 333.5 11,461 3.9 44,699
Transverse Roof Zone D 1 0.31 42.8 7.51 320.7 116 7.8 908
STRENGTH LEVEL Lateral force/Moment 7,630 59,518
CONVERT TO ALLOWABLE STRESS DESIGN 4,578 :35,711
Vertical Wind Loads
Transverse Roof Zone E -26.9 9.2 24.0 221.8 -7,218 36.0 259,850
Transverse Roof Zone F -24.8 9.2 24.0 221.8 -6,655 12.0 79,855
Transverse Roof Zone G -19.0 42.8 24.0 1,026.2 -23,593 36.0 849,357
Transverse Roof Zone H -19.3 42.8 24.0 1,026.2 -23,966 12.0 287,589
Roof Overhang Zone E -41.9 9.21 1.3 12.3 -623 48.7 30,321
Roof Overhang Zone F -24.8 9.2 1.3 12.3 -369 -0.7 -245
Roof Overhang Zone G -33.9 42.8 1.3 56.9 -2,333 48.7 113,525
Roof Overhang Zone H L -19.3 42.8 1.31 56.9 -1,328 -0.7 -883
STRENGTH LEVEL Uplift Force and Overturning Moment on Building -66,084 1,619,369
CONVERT TO ALLOWABLE STRESS DESIGN -39,651 971,621
Total Overturning Moment Due to Transverse Wind Loading (ASD) 1,007,332
Unit Uplift on Building (psf) -18.81 1
LONGITUDINAL WIND LOADING
Horizontal Wind Loads
Longitudinal Wall Zone A 31.1 9.2 9.7 89.9 3,381 4.9 16,442
Longitudinal Wall Zone B 0.0 9.2 0.0 0.0 0 7.8 0
Longitudinal Wall Zone C 20.6 38.8 13.5 524.5 13,075 6.8 88,470
Longitudinal Wall Zone D 1 0.01 38.8 0.01 0.0 0 7.8 0
STRENGTH LEVEL'Lateral Force/Moment 10,320 104,913
CONVERT-TO ALLOWABLE STRESS DESIGN 6,192 62,948
Vertical Wind Loads
Longitudinal Roof Zone E -37.3 9.2 26.0 240.2 -10,843 39 422,867
Longitudinal Roof Zone F -21.2 9.2 26.0 240.2 -6,163 13 80,114
Longitudinal Roof Zone G -26.0 38.8 26.0 1,007.8 -31,704 39 1,236,461
Longitudinal Roof Zone H -16.4 38.8 26.0 1,007.8 -19,998 13 259,974
Roof Overhang Zone E -52.3 9.2 1.0 9.2 -585 52.5 30,699
Roof Overhang Zone F -21.2 9.2 1.0 9.2 -237 -0.5 119
Roof Overhang Zone G -40.9 38.8 1.0 38.8 -1,918 52.5 100,705
Roof Overhang Zone H 1 -16.4 38.81 1.01 38.8 -769 -0.5 -385
STRENGTH LEVEL Uplift Force and Overturning Moment on Building -72,217 2,130,554
CONVERT TO ALLOWABLE STRESS DESIGN -43,330 1,278,333
Total Overturning Moment Due to Longitudinal Wind Loads (ASD) 1,341,280
Unit Uplift on Building (psf) -20.5
Note:
(+)and (-)signs signify wind pressures acting toward and away from the projected surfaces, respectively per ASCE Standard
7-10.
Revised WIND LOADS Printed
11/1/2013 Plan 2112-13 30-PSF Snow, 110 mph, Exp C, & SDC D2-ADAMS; 11/13/2013
A. Abrous, Ph.D., P.E. HiLine Homes Page 13 of 20
TABLE EO2. WIND LOADS (GARAGE)
Wind Zone Zone Zone Area Zone Moment Moment
Zone Pressure Width Ht./Leng. Force Arm
(Psfl (ft) (ft) (sf) (lb) (ft) (ft-Ib)
TRANSVERSE WIND LOADING
Horizontal Wind Loads
Transverse Wall Zone A 40.9 6.0 7.8 46.8 2,316 3.9 9,033
Transverse Roof Zone B 0.0 6.0 5.0 30.0 0 7.8 0
Transverse Wall Zone C 28.4 16.0 7.8 124.8 4,289 3.9 16,726
Transverse Roof Zone D 0.3 16.0 5.0 80.0 29 7.8 227
STRENGTH.LEVEL Lateral Force/Moment 3,331 25,985
,,CONVERT TOALLOWABLE STRESS DESIGN] 1,999 15,591
Vertical Wind Loads
Transverse Roof Zone E -26.9 6.0 12.0 72.0 -21344 18.0 42,184
Transverse Roof Zone F -24.8 6.0 12.0 72.0 -2,161 6.0 12,963
Transverse Roof Zone G -19.0 16.0 12.0 192.0 -4,414 18.0 79,453
Transverse Roof Zone H -19.3 16.0 12.0 192.0 -4,484 6.0 26,903
Roof Overhang Zone E -41.9 6.0 1.3 8.0 -405 24.7 9,979
Roof Overhang Zone F -24.8 6.0 1.3 8.0 -239 -0.7 -159
Roof Overhang Zone G -33.9 16.0 1.3 21.3 -873 24.7 21,530
Roof Overhang Zone H 1 -19.3 16.0 1.31 21.3 -497 -0.7 -330
STRENGTH LEVEL Uplift Force and Overturning Moment on Building -15,416 192,522
CONVERT TO ALLOWABLE STRESS DESIGN -9,250 115,513
Total Overturning Moment Due to Transverse Wind Loading (ASD) 131,104
Unit Uplift on Building (psf) --4.41 1
LONGITUDINAL WIND LOADING
Horizontal Wind Loads
Longitudinal Wall Zone A 31.1 6.0 9.1 54.3 2,043 4.5 9,246
Longitudinal Wall Zone B 0.0 6.0 0.0 0.0 0 7.8 0
Longitudinal Wall Zone C 20.6 18.0 10.7 192.9 4,808 5.4 25,764
Longitudinal Wall Zone D 1 0.0 18.0 0.0 0.0 0 7.8 0
STRENGTH LEVELLateral Force/Moment 3,640 35,010
CONVERT TO ALLOWABLESTRESS DESIGN '2,184 21,006
Vertical Wind Loads
Longitudinal Roof Zone E -37.3 6.0 11.0 66.0 -2,979 16.5 49,150
Longitudinal Roof Zone F -21.2 6.0 11.0 66.0 -1,693 5.5 9,312
Longitudinal Roof Zone G -26.0 18.0 11.0 198.0 -6,229 16.5 102,780 .
Longitudinal Roof Zone H -16.4 18.0 11.0 198.0 -3,929 5.5 21,610
Roof Overhang Zone E -52.3 6.01 1.0 6.0 -380 22.5 8,543
Roof Overhang Zone F -21.2 6.0 1.0 6.0 -154 -0.5 77
Roof Overhang Zone G -40.9 18.0 1.0 18.0 -891 22.5 20,043
Roof Overhang Zone H -16.4 18.0 1.0 18.0 -357 -0.5 -179
STRENGTH LEVEL Uplift Force and Overturning Moment on Building -16,612 211,336
CONVERT TO ALLOWABLE STRESS DESIGN -9,967 126,802
Total Overturning Moment Due to Longitudinal Wind Loads (ASD) 147,808
Unit Uplift on Building (psf) -4.7
Note:
(+)and (-) signs signify wind pressures acting toward and away from the projected surfaces, respectively per ASCE Standard
7-10.
Revised WIND LOADS Printed
11/1/2013 Plan 2112-13 30-PSF Snow, 110 mph, Exp C, & SDC D2-ADAMS 11/13/2013
A. Abrous, Ph.D., P.E. HiLine Homes Page 14 of 20
TABLE F-1. MINIMUM IND LOADS (HOUSE)
Wind Zone Zone Zone Area Zone Moment Moment
Zone Pressure Width Ht./Leng. Force Arm
(psf) (ft) (ft) (s (lb) (ft) (ft-Ib)
TRANSVERSE WIND LOADING
Horizontal Wind Loads
Transverse Wall Zone A 16.0 9.2 7.8 72.1 1,153 3.9 4,497
Transverse Roof Zone B 8.0 9.2 7.5 69.3 554 7.8 4,324
Transverse Wall Zone C 16.0 42.8 7.8 333.5 5,336 3.9 20,812
Transverse Roof Zone D 1 8.01 42.8 7.5 320.7 2,566 7.8 20,012
w STRENGTH-L'EVEL�Lateral:Force/Moment -,.:--6;365' 49;645'
'CONVERT TO"ALLOWABLE'STRESS DESIGN 3;819; 29,787:
Vertical Wind Loads
Transverse Roof Zone E 0.0 9.2 24.0 221.8 0 36.0 0
Transverse Roof Zone F 0.0 9.2 24.0 221.8 0 12.0 0
Transverse Roof Zone G 0.0 42.8 24.0 1,026.2 0 36.0 0
Transverse Roof Zone H 0.0 42.8 24.0 1,026.2 0 12.0 0
Roof Overhang Zone E 0.0 9.21 1.3 12.3 0 48.7 0
Roof Overhang Zone F 0.0 9.2 1.3 12.3 0 -0.7 0
Roof Overhang Zone G 0.0 42.8 1.3 56.9 0 48.7 0
Roof Overhang Zone H 0.0 42.8 1.3 56.9 0 -0.7 0
STRENGTH LEVEL Uplift Force and Overturning Moment on Building 0 0
CONVERT TO ALLOWABLE STRESS DESIGN 0 0
Total. Overturning Moment Due to Transverse Wind Loading (ASD) 29,787
Unit Uplift on Building (psf) 0.0
LONGITUDINAL WIND LOADING
Horizontal Wind Loads
Longitudinal Wall Zone A 16.0 9.2 9.7 89.9 1,438 4.9 6,991
Longitudinal Wall Zone B 8.0 9.2 0.0 0.0 0 7.8 0
Longitudinal Wall Zone C 16.0 38.8 13.5 524.5 8,393 6.8 56,789
Longitudinal Wall Zone D 8.0 38.8 0.0 0.0 0 7.8 0
STRENGTH'LEVEL'Lateral'Force/Moment' '6;405 x63;780;
CONVERT TO,ALLOWABLE.STRESS DESIGN 3843 38,268'
Vertical Wind Loads
Longitudinal Roof Zone E 0.0 9.2 26.0 240.2 0 39 0
Longitudinal Roof Zone F 0.0 9.2 26.0 240.2 0 13 0
Longitudinal Roof Zone G 0.0 38.8 26.0 1,007.8 0 39 0
Longitudinal Roof Zone H 0.0 38.8 26.0 1,007.8 0 13 0
Roof Overhang Zone E 0.0 9.21 1.0 9.2 0 52.5 0
Roof Overhang Zone F 0.0 9.2 1.0 9.2 0 -0.5 0
Roof Overhang Zone G 0.0 38.8 1.0 38.8 0 52.5 0
Roof Overhang Zone H 1 0.0 38.8 1.01 38.8 0 -0.5 0
STRENGTH LEVEL Uplift Force and Overturning Moment on Building 0 0
CONVERT TO ALLOWABLE STRESS DESIGN 0 0
Total Overturning Moment Due to Longitudinal Wind Loads (ASD) 38,268
Unit Uplift on Building (psf)l 0.01 1
Note:
(+)and (-)signs signify wind pressures acting toward and away from the projected surfaces, respectively per ASCE Standard
7-10.
Revised MINIMUM WIND LOADS Printed
11/1/2013 Plan 2112-13 30-PSF Snow, 110 mph, Exp C, & SDC D2-ADAMS 11/13/2013
A. Abrous, Ph.D., P.E. HiLine Homes Page 15 of 20
TABLE F-2. MINIMUM WIND LOADS (GARAGE)
Wind Zone Zone Zone Area Zone Moment Moment
Zone Pressure Width Ht./Leng. Force Arm
(psf) (ft) (ft) (sf) (lb) (ft) (ft-Ib)
TRANSVERSE WIND LOADING
Horizontal Wind Loads
Transverse Wall Zone A 16.0 6.0 7.8 46.8 749 3.9 2,920
Transverse Roof Zone B 8.0 6.0 5.0 30.0 240 7.8 1,872
Transverse Wall Zone C 16.0 16.0 7.8 124.8 1,997 3.9 7,788
Transverse Roof Zone D 1 8.01 16.0 5.01 80.0 640 7.8 4,992
STRENGTH LEVEL Lateral Force/Moment 2,253 17,572
CONVERT TO ALLOWABLE STRESS DESIGN 1;352 101543
Vertical Wind Loads
Transverse Roof Zone E 0.0 6.0 12.0 72.0 0 18.0 0
Transverse Roof Zone F 0.0 6.0 12.0 72.0 0 6.0 0
Transverse Roof Zone G 0.0 16.0 12.0 192.0 0 18.0 0
Transverse Roof Zone H 0.0 16.0 12.0 192.0 0 6.0 0
Roof Overhang Zone E 0.0 6.01 1.3 8.0 0 24.7 0
Roof Overhang Zone F 0.0 6.0 1.3 8.0 0 -0.7 0
Roof Overhang Zone G 0.0 16.0 1.3 21.3 0 24.7 0
Roof Overhang Zone H 1 0.0 16.0 1.31 21.3 0 -0.7 0
STRENGTH LEVEL Uplift Force and Overturning Moment on Building 0 0
CONVERT TO ALLOWABLE STRESS DESIGN 0 0
Total Overturning Moment Due to Transverse Wind Loading (ASD) 10,543
Unit Uplift on Building (psf)l 0.01 L
LONGITUDINAL WIND LOADING
Horizontal Wind Loads
Longitudinal Wall Zone A 16.0 6.0 9.1 54.3 869 4.5 3,931
Longitudinal Wall Zone B 8.0 6.0 0.0 0.0 0 7.8 0
Longitudinal Wall Zone C 16.0 18.0 10.7 192.9 31086 5.4 16,538
Longitudinal Wall Zone D 1 8.01 18.0 0.01 0.0 01 7.81 0
STRENGTH:LEVEL Lateral Force/Moment 2,2101 1 20,469
CONVERT TO ALLOWABLE STRESS DESIGN 1.,326 12,282
Vertical Wind Loads
Longitudinal Roof Zone E 0.0 6.0 11.0 66.0 0 16.5 0
Longitudinal Roof Zone F 0.0 6.0 11.0 66.0 0 5.5 0
Longitudinal Roof Zone G 0.0 18.0 11.0 198.0 0 16.5 0
Longitudinal Roof Zone H 0.0 18.0 11.0 198.0 0 5.5 0
Roof Overhang Zone E 0.0 6.01 1.0 6.0 0 22.5 0
Roof Overhang Zone F 0.0 6.0 1.0 6.0 0 -0.5 0
Roof Overhang Zone G 0.0 18.0 1.0 18.0 0 22.5 0
Roof Overhang Zone H 1 0.0 18.0 1.01 18.0 0 -0.5 0
STRENGTH LEVEL Uplift Force and Overturning Moment on Building 0 0
CONVERT TO ALLOWABLE STRESS DESIGN 0 0
Total Overturning Moment Due to Longitudinal Wind Loads (ASD) 12,282
Unit Uplift on Building (psf) 0.0
Note:
(+)and (-) signs signify wind pressures acting toward and away from the projected surfaces, respectively per ASCE Standard
7-10.
Revised MINIMUM WIND LOADS Printed
11/1/2013 Plan 2112-13 30-PSF Snow, 110 mph, Exp C, & SDC 132_ADAMS 11/13/2013
A. Abrous, Ph.D., P.E. HiLine Homes Page 16 of 20
TABLE G. SEISMIC LOADS
SEISMIC SHEAR LOADS ON HOUSE
Load
Height/ Length Area Seismic Seismic
Building Component (psf) Width (ft) (sf) Weight Shear
ft Ib Ib
Roof Diaphragm &Ceiling 15.0 2,112 31,680 5,702
20%of Flat Roof Snow Load >30-psf 0.01 1 2,112 0 0
One-Half Exterior Walls 15.0 7.8 200.01 1,560 11,700 2,106-
One-Half Partitions 10.01 2,112 10,560 1,901
Total Dead Load for Restoring Moment 76,200
Roof Diaphragm Tributary Dead Load 53,940
_ STRENGTH.LEVEL BASE SHEAR .%709
CONVERTTO ALLOWABLE STRESS"DESIGN BASE:SHEAR 61796
SEISMIC SHEAR LOADS ON GARAGE
Roof Diaphragm &Ceiling 15.0 528 7,920 1,426
20% of Flat Roof Snow Load > 30-psf 0.0 528 0 0
One-Half Exterior Walls 15.0 7.8 92.0 718 5,382 969
One-Half Partitions 10.0 0 0 0
Total Dead Load for Restoring Moment 18,684
Roof Diaphragm Tributary Dead Load 13,302
STRENGTH LEVEL BASE SHEAR 2,394.
CONVERT TO ALLOWABLE STRESS"DESIGN BASE SHEAR -1,67.6
OVERTURNING ANALYSIS DUE TO TRANSVERSE LOADS - HOUSE
Building Component Force Dist. Moment
(lb) (ft) (ft-Ib)
Roof Diaphragm & Ceiling 5,702 7.8 44,479
Exterior Walls 2,106 7.8 16,427
Partitions 1,901 7.81 14,826
Total Dead Load 76,200 24.0 1,828,800
Total Moment Due to Transverse Seismic Forces 75,732
Total Moment Due to Transverse Wind Forces 1,007,332
Total Restoring Moment in Transverse Loading 1,828,800
6/10 of Total Restoring Moment in Transverse Loading 1,097,280
OVERTURNING STABILITY YES
OVERTURNING ANALYSIS DUE TO LONGITUDINAL LOADS
Building Component Force Dist. Moment
Ib ft ft-Ib
Roof Diaphragm & Ceiling 5,702 7.8 44,479
Exterior Walls 2,106 7.8 16,427
Partitions 1,901 7.81 14,826
Total Dead Load 76,200 26.0 1,981,200
Total Moment Due to Longitudinal Seismic Forces 75,732
Total Moment Due to Longitudinal Wind Forces 1,341,280
Total Restoring Moment in Longitudinal Loading 1,981,200
6/10 of Total Restoring Moment in Longitudinal Loading 1,188,720
OVERTURNING STABILITY YES
Revised SEISMIC LOADS Printed
11/1/2013 Plan 2112-13 30-PSF Snow, 110 mph, Exp C, & SDC D2_ADAMS 11/13/2013
A. Abrous, Ph.D., P.E. HiLine Homes Page 17 of 20
TABLE H. CONTROLLING SHEAR LADS
House
Floor Level Main Floor Level Second Floor Level
Type Load Transverse Longitudinal Transverse Longitudinal
ASD Wind Load (Ib) 4,578 6,192 N/A N/A
ASD Minimum Wind Load (Ib) 3,819 3,843 N/A N/A
ASD Controlling Wind:Load (lb) 49578 6,192 N/A N/A
ASD Seismic Diaphragm Load (Ib) 6,796 69796 N/A `N/A
Nature of Controlling Load SEISMIC SEISMIC N/A N/A
ASD Maximum wind/seismic load (Ib) 6,796 6,796 N/A N/A
Garage
Type Load Transverse Longitudinal Transverse Longitudinal
ASD Wind Load (Ib) 1,999 2,184 N/A N/A
ASD Minimum Wind Load (Ib) 1,352 1,326 N/A N/A
ASD Controlling Wind-Loafllb) 1;999 .-2,184 N/A 'N/A
ASD Seismic Diaphragm.Load (Ib) 1,676 9,676 N/A N/A
Nature of Controlling Load WINDI WIND N/A N/A
ASD Maximum wind/seismic load (Ib) 1,9991 2,184 N/A N/A
House + Garage
Floor Level Main Floor Level Second Floor Level
Type Load Transverse Longitudinal Transverse Longitudinal
ASD Controlling Wind'Load (lb) 6,577 :6,192 N/A 'N/A
ASD Seismic Diaphragm Load (Ib) .8,472 8,472 N/A 'N/A
NOTE: ASD =ALLOWABLE STRESS DESIGN
Revised CONTROLLING LOADS Printed
11/1/2013 Plan 2112-13 30-PSF Snow, 110 mph, Exp C, & SDC D2—ADAMS 11/13/2013
A. Abrous, Ph.D., P.E. HiLine Homes Page 18 of 20
TABLE 1. WIND SHEAR WALL LOADS
TRANSVERSE LOADS
Floor Level Main Floor Level
Wall Identification 1 2 3 4 Check
Wall Type OSB OSB OSB OSB Total
Tributary Load Distance (ft)- H 26.0 14.0 26.0 52.0
Tributary Load Fraction - H 0.500 0.269 0.500
Tributary Load Distance (ft)- G 11.000 11.0
Tributary Load Fraction -G 0.500 0.500
Applied Shear(lb) 999 3,2891 1,233 2,289 71810
Wall Length (ft) 24.0 32.0 48.0 48.0
Applied UnitrSheara(Ib/ft) .: 42 :1-03 -`,26 r _ . 48 .< -
Shear Wall Length (ft) 24.0 21.0 16.0 42.0
Resistive Unit.Shear(Ililft) 42 15Z 777 55
Shear Wall Height(ft) 7.8 7.8 7.8 7.8
Unit DL on Wall (Ib/ft) 150 150 350 150
0.60*[Unit DL on Wall] (Ib/ft) 90 90 210 90
Max. Hold-Down,24:0-ftSW (lb) -75
Max. Hold-Down 5.-O=ft SW (lb) 996
Max. Hold-Down 15.0-ft SW (lb) - -250
Max. Hold-Down 16.0-ft SW (lb) 501 -1;079
Max. Hold-Down 27.0-ft SW (lb) 1 -790
LONGITUDINAL LOADS
Floor Level Main Floor Level Second Level
Wall Identification A B C D Check
Wall Type OSB OSB OSB OSB Total
Tributary Load Distance (ft)- H 8.0 24.0 16.0 48.0
Tributary Load Fraction - H 0.167 0.500 0.333 1.0
Tributary Load Distance (ft)- G 1 12.0 12.0 24.0
Tributary Load Fraction -G 0.500 0.500 1.0
Applied Shear(Ib) 1,032 3,096 1,092 2,064 7,284
Wall Length (ft) 28.0 52.0 22.0 74.0
Applied Unit Shear:(Ib/ft) 37 160 `50: " _ 28
Shear Wall Length (ft) 18.0 21.01 6.0 55
Resistive Unit Shear(Iblft) 57 ':147 1'82 s 38 3
Shear Wall Height(ft) 7.8 7.8 7.8 7.8
Unit DL on Wall (Ib/ft) 150 450 320 380
0.60*[Unit DL on Wall] (Ib/ft) 90 270 192 228
Max. Hold-Down 3.0-ft SW (lb) 1,132
Max. Hold-Down 4.0=ft SW (lb) -163
Max. Hold-Down 5.0-ft-SW (lb) 222 475 -277
Max. Hold-Down 7:5-ft SW (lb) -562
Max. Hold-.Down 8.0-ft.SW (lb) -.87
Max. Hold-Down 9:04t-SW (lb) -733
Max. Hold-Down-11.0-ft SW (Ib) .-335
Max. Hold-Down 22.0-ft SW (lb) -1,819
Revised WIND SHEAR LOADS Printed
11/1/2013 Plan 2112-13 30-PSF Snow, 110 mph, Exp C, & SDC D2-ADAMS 11/13/2013
A. Abrous, Ph.D., P.E. HiLine Homes Page 19 of 20
TABLE J. SEISMIC SHEAR WALL LOADS
TRANSVERSE LOADS
Floor Level Main Floor Level
Wall Identification 1 2 3 4 Check
Wall Type OSB 0S13 OSB 0S13 Total
Tributary Load Distance (ft)- H 26.0 14.0 26.0 52.0
Tributary Load Fraction - H 0.500 0.269 0.500
Tributary Load Distance(ft)-G 11.000 11.0
Tributary Load Fraction -G 0.500 0.500
Applied Shear(lb) 838 4,2361 1,830 3,398 10,302
Wall Length (ft) 24.0 32.0 48.0 48.0
X35. ..... 13211,1�k-1--,
N,
Pi
Shear Wall Length (ft) 24.0 21,0 116.0 42.0
.Resi6tive�Urilt'•Shear-,.'(iii/,ft),, 202 1
Shear Wall Height(ft) 7.8 7.8 7.8 7.8 1
Unit DL on Wall (lb/ft) 150 4950 350 150
0.60*[Unit DL on Wall] (lb/ft) 90 90 210 90
Max, Hold-Down 24.0-ft SVIV _J
(I b)- -80 2,
.Max..iHold Down,'5-0-ft SW -1,34$
Max. Hold-'Down 15:0-ft,SW (lb). -44
Max.'Hold-'Down 16.0-ft'SW,(b) 853 -7891-
�Max.'Hol&Down,27.,0-ft'SW�,(lb) =584
LONGITUDINAL LOADS
Floor Level Main Floor Level Second Level
Wall Identification A B C D Check
Wall Type 0S13 0S13 0S13 0S13 Total
Tributary Load Distance (ft) - H 8.0 24.0 16.0 48.0
Tributary Load Fraction - H 0.167 0.500 0.333 1.0
Tributary Load Distance (ft)-G 12.0 12.0 1 24.0
Tributary Load Fraction - G 0.500 0.500 1.0
Applied Shear(lb) 1,133 3,398 838 3,104 8,472
Wall Length (ft) 28.0 52.0 22.0 74.0
Ap,oliediOnit,-Shear(Ib7f.t)L '-"L; --39
Shear Wall Length (ft) 18.0 24.01 6.0 55
�Resistivi6°Unit*-Shear4(16/ft,),_w: ,x l X63 :162 140 156
Shear Wall Height(ft) 7.8 7.8 7.8 7.8
Unit DL on Wall (lb/ft) 150 450 320 380
0.60*[Unit DL on Wall] (lb/ft) 90 270 192 228
`Max. Hold-Down-3.0-ft SW (lb) S01' 452
Max.{Hold-Down 4:04V'SW (Ib) A6
Max. Hold-Down &0-',ftSW-,(lb)� 5 8 7, A30
Max. Hold7Down 7.5-ft SW (lb)
-415
Mak-Hold-,Down 8.0-ft SW (Ib)
Max.,,Hold-'Down.9:0-f,t�SW�(lb)
Max.-Hold-Down 11.07ft,'SW1'(lb)
L
Kai. Hold-n_own 22.0-ft,SW (lb)__ `1 -
Revised SEISMIC SHEAR LOADS Printed
11/1/2013 Plan 2112-13 30-PSF Snow, 110 mph, Exp C, & SDC D2-ADAMS 11/13/2013
A. Abrous, Ph.D., P.E. HiLine Homes Page 20 of 20
TABLE K. ROOF DIAPHRAGM CALCULATIONS
DIAPHRAGM CHORD SPLICE & STRESS CALCULATIONS
Maximum Transverse Shear Load (lb) Calculation V= 4,578
Diaphragm Span (ft) Design Drawings b= 48
Diaphragm Length (ft) Design Drawings L = 52.0
Diaphragm Unit Shear(Ib/ft) Calculation w=V/Length = 88
Diaphragm Maximum Moment(ft-Ib) Calculation M =wL2/8 = 29,759
Diaphragm Chord Force Calculation - C T' 'M/b }ti626
Allowable Nail Load (lb) NDS Table 11 N H-F & 10d Common 102
Adjustment For Wind/Seismic Loads NDS Table 2.3.2 10-minute loads 1.6
Adjusted Allowable Nail Load (lb) Calculation F = 1.6FNail 163.2
Minimum Number of Nails Required At Splices Calculation NN-Min= C/FA 3.8
Maximum Nail Spacing at Splices (in) Design Drawings S = 6.0
Minimum Splice Length (in) Calculation Ls lice-SNN-Min 22.8
Design Splice Length (in) Design Drawings Design Specification 48.0
Allowable Diaphragm Chord;Force(Ib) P Calculation , ' ` - : 1:0d @=6-in,o.c. -= 1,469
Cross Sectional Area of Shear Wall Chords int Design Drawings Achord =2(1.5)(5.5) = 16.5
Axial Chord Stess (psi) Calculation Fart= C/A=T/A 38
Allowable Parallel Compressive Stress (psi) WWPA Table 1 No. 2 Hem-Fir 1,250
Allowable Parallel Tensile Stress (psi) WWPA Table 1 No. 2 Hem-Fir 500
ROOF UPLIFT CALCULATIONS
Roof Truss Span, b (ft) Design Drawings 32.0
Tributary Area to Truss Connection (sf) Trusses @ 24-in o.c. JA= 2b/2 = b 32.0
Maximum Wind Uplift Pressure, 85 mph, C (psf) Calculated [0.5*(0.6*(23.1+16.0)] x 1.21 -14.2
Maximum Wind Uplift Pressure, 95 mph, C (psf) Calculated [0.5*0.6*(27.4+19.1)] x 1.21 -16.9
Maximum Wind Uplift Pressure, 110 mph, C (psf) Calculated [0.5*0.6*(37.3+26.0)]x 1.21 -23.0
Maximum Wind Uplift Load At Connection (lb) 85 mph, Exp. C up= P -453
Maximum Wind Uplift Load At Connection (lb) 95 mph, Exp. C up= P -541
Maximum Wind Uplift Load At Connection (lb) 110 mph, Exp. C Fup= P -736
Roof Unit Dead Load, wd,(psf) Design Criteria 15.0
Roof Dead Load to Truss Connection (lb) FDL=0.6 wdjA 288
Net Load to Truss Connection (lb) 85 mph, Exp. C FNet- Fup + FDL -165
Net Load to Truss Connection (lb) 95 mph, Exp. C FNet- FUP + FDL -253
Net Load to Truss Connection (lb) 110 mph, Exp. C FNet- Fup+ FDL -448
Allowable Uplift for Simpson H10 Clip(lb) SPF/Hem-Fir with 160% Increase 850
Allowable Uplift For Simpson H2.5A Clip (lb) SPF/Hem-Fir with 160% Increase 535
Allowable Uplift For Simpson 1-11 Clip(lb) SPF/Hem-Fir with 160% Increase 400
Revised ROOF DiAPHRAGM CALCULATIONS Printed
11/1/2013 Plan 2112-13 30-PSF Snow, 110 mph, Exp C, & SDC D2—ADAMS 11/13/2013
GENERAL CONSTRUCTION NOTES HEADER& ROOF FRAMING NOTES FOUNDATION& LATERAL DESIGN CRITERIA
FLOOR FRAMING NOTES AND MINIMUM SITE CONDITIONS INFORMATION
1. SUB-CONTRACTOR IS RESPONSIBLE FOR THE FOLLOWING:VERIFYING AND MEETING 1. HEADERS OCCUPANCY CATEGORY II
ALL LOCAL AND STATE CODE REQUIREMENTS,REVIEWING APPROVED PLANS AND 1.1. UNLESS NOTED OTHERWISE,ALL EXTERIOR 1. ALL FOOTINGS SHALL BEAR ON STIFF,FIRM SOIL BASIC WIND SPEED MPH 110
COMPLYING WITH ALL APPROVED REQUIREMENTS OF THE ENGINEER AND THE WALL HEADERS SUPPORTING ROOF LOADS ARE MEETING THE REQUIREMENTS OF DEFAULT SITE WIND EXPOSURE FACTOR C E
BUILDING DEPARTMENT,MEETING ALL SAFETY REQUIREMENTS AND STANDARD TO BE A MIN.4 x 8 D.F.#2 W/R-10 RIGID CLASS"D"PER IBC SECTION 1613.5.2.DESIGN IS MINIMUM WIND LOADS(PSF) 16/8 ci 0 E
SAFETY PRACTICES THAT ARE RECOMMENDED AND/OR REQUIRED BY STATE AND INSULATION AT HEATED AREAS. BASED ON 1500 p.s.f.SOIL.CONTRACTOR MUST SEISMIC/WIND IMPORT.FACTOR I
LOCAL AUTHORITIES, VERIFYING ACCURACY OF ALL DIMENSIONS.DO NOT SCALE 1.2. U.N.O.ALL EXTERIOR WALL HEADERS VERIFY W/BUILDING DEPARTMENT THAT THESE ' W d)
SEISMIC USE GROUP 1.0 =
THE DRAWINGS.IF DISCREPANCIES OCCUR PLEASE CONTACT THE DESIGNER. SUPPORTING ROOF AND FLOOR LOADS ARE TO CONDITIONS ARE MET PRIOR TO WORK. E
SEISMIC DESIGN CATEGORY D2
BE 4 x10 D.F.#2 W/R-10 RIGID INSULATION AT =
SHORT PERIOD ACCELERATION 1.17
2. ALL WOOD IN CONTACT WITH CONCRETE OR SOIL � c N
2. NO CHANGES ARE TO BE MADE TO THE PLANS WITHOUT THE CONSENT OF THE HEATED AREAS. a
DESIGNER AND BUILDING DEPARTMENT. 1.3. ALL SINGLE STORY NON-STRUCTURAL GABLE SHALL BE 2x HEM-FIR#2 MIN.TREATED WITH AN DEFAULT SITE CLASS D J
APPROVED PRESERVATIVE AND HOT-DIPPED MAXIMUM GROUND SNOW LOAD PSF 30 =.a
END OR 2nd FLOOR OF 2 STORY ��❑
3. THIS STRUCTURE IS ENGINEERED LATERALLY USING THE DESIGN CRITERIA SHOWN NON-STRUCTURAL GABLE END HEADERS UP TO GALVANIZED CONNECTORS(OR)STANDARD ROOF DEAD LOAD(PSF) 15 °
ON SHEET"CS".THIS PLAN HAS BEEN DESIGNED TO CARRY ALL LOADS FROM THE 6'-0"TO BE SINGLE 2x6 H.F.#2 PER DETAIL 6 ON HEM-FIR ON AN IMPERVIOUS MOISTURE BARRIER EXTERIOR WALL DEAD LOAD(PSF) 15
ROOF TO THE FOUNDATION. SHEET A4. (IRC R317.1)(OR)BORATE TREATED HEM-FIR#2 INTERIOR WALL DEAD LOAD(PSF) 10 =
MINIMUM. MAXIMUM ROOF SLOPE 5/12
4. SEE SHEET"S2"FOR ALL SHEARWALL PLACEMENTS AND REQUIREMENTS. 2. UNLESS NOTED OTHERWISE,JOISTS AND RAFTERS 3. PROVIDE APPROPRIATE BLOCK-OUTS IN FOOTINGS GENERAL STRUCTURAL NOTES:
SHEARWALL DETAILS MUST BE FOLLOWED EXACTLY. NOTIFY THE DESIGNER OF ANY ARE TO BE A MIN.H.F.#2.RAFTERS MUST BE OR WALLS FOR PLUMBING&ELECTRICAL WIND AND SEISMIC NATURAL FORCES IMPOSED ON THIS
DISCREPANCIES OR CONCERNS. SUPPORTED BY POSTING DOWN TO FLAT BLOCKING STUB-OUTS.
THAT SPANS A MIN.OF TWO TRUSSES WHEN THAT ARE RESISTED BY A SYSTEM OF ENGINEERED
5. FIRE BLOCKING IS REQUIRED AT ALL PENETRATIONS AT THE WALLS AND PLATES, MEMBERS AND FASTENERS DESIGNED TO RESIST DESIGN
RAFTER SPANS EXCEED 6 FT. 4. WHERE REQUIRED,USE A MIN.OF 3000 p.s.i. BASE LOADS SET FORTH BY THE CRITERIA OPTIONS LISTED
INCLUDING:PLUMBING,ELECTRICAL,AND MECHANICAL PENETRATIONS.FIRE BLOCK CONCRETE PER IRC TABLE R402.2,INCLUDING:
AT MIN.10 FT.O.C.HORIZONTALLY IN WALL CAVITIES. 3. TRUSSES SHALL CARRY MANUFACTURER STAMP FOUNDATION WALLS,PORCH AND GARAGE SLABS, ABOVE.THE STRUCTURAL SYSTEM IS DESIGNED TO Q �
AND HAVE ENGINEERING DRAWINGS ON SITE FOR STEPS,AND ALL OTHER AREAS THAT ARE EXPOSED TRANSFER LOADS IN ACCORDANCE WITH THE 2012 U) ch
6. WATER HEATER IS TO BE INSTALLED PER MANUFACTURER SPECIFICATIONS,IRCINSPECTION.ALL TRUSS BRACING REQUIREMENTS TO THE WEATHER.MAXIMUM STRENGTH IS AT 28 INTERNATIONAL BUILDING CODE(IBC)TO A PRESCRIPTIVE 00
REQUIREMENTS,AND THE STATE ADOPTED PLUMBING CODE.IN SDC D1,D2,TANK FOUNDATION.STRUCTURAL MEMBERS NOT A PART OF THE
MUST BE INSTALLED PER TRUSS DRAWINGS.DO DAYS.ALLOW ADEQUATE TIME FOR FOUNDATION � Q tp
MUST BE STRAPPED AT THE UPPER AND LOWER THIRD OF THE TANK.AT THE LOWERNOT FIELD MODIFY ANY TRUSS WITHOUT PRIOR TO SET BEFORE BACK FILLING. ENGINEERED STRUCTURAL SYSTEM SHALL BE -1 Z
CONSTRUCTED IN ACCORDANCE`WITH THE CONVENTIONAL w CC
04
STRAP,STRAP IS TO BE 4"MIN.ABOVE THE CONTROLS(IRC M1307.2). APPROVAL FROM THE ENGINEER AND BUILDING LIGHT-FRAME CONSTRUCTION'REQUIREMENTS OF 2012 IRC. G
DEPARTMENT.IF A TRUSS IS DAMAGED DO NOT 5. FOUNDATION VENTS ARE TO BE INSTALLED AT >- W ti
7. WHEN INSTALLED IN A GARAGE,ALL APPLIANCES MUST HAVE THE SOURCE OF INSTALL IT.CONTACT THE BUILDER IMMEDIATELY 1/300 FT2 EVENLY PLACED TO PROVIDE CROSS Q J -•I ~
IGNITION A MINIMUM OF 18"ABOVE THE FLOOR SLAB IRC M1307.3).MECH/PLUMBING � O W
( FOR A REPLACEMENT TRUSS. VENTILATION EXCEPT THAT ONE SIDE IS
EQUIPMENT IS TO BE PROTECTED FROM IMPACT OF A VEHICLE(IRC M1307.3.1). PERMITTED TO HAVE NO OPENINGS.THE NET FREE DOCUMENT SHEET INDEX F-- Q N z 0
4. FRAMING CONNECTIONS SHALL BE"SIMPSON AREA MAY BE REDUCED TO 1/1500 FT2 IF GROUND Q
CS COVER SHEET
8. USE 5/8"GYPSUM OR 1/2"SAG-RESISTANT GYPSUM AT THE CEILING PER IRC TABLE STRONG TIE"(OR)AN APPROVED EQUIVALENT. SURFACE IS COVERED W/6 MIL.BLACK POLY O �
R702.3.5. SHEETING AND VENTS ARE PLACED TO PROVIDE Al FLOOR PLAN
5. PROVIDE ATTIC VENTILATION PER IRC R806.2.THE CROSS VENTILATION OF THE SPACE.IRC R408.2 A2 BUILDING SECTIONS U O
9. FLASHING IS REQUIRED AT ALL EXTERIOR TRIM EXTRUSIONS,WINDOW AND DOOR NET FREE VENTILATED AREA SHALL BE 1/300 FT' A3 EXTERIOR ELEVATIONS W 0-
OPENINGS,WALL AND ROOF INTERSECTIONS,DECK ATTACHMENT TO WALL,AND PROVIDED THAT MIN.50%AND MAX.80%OF THE & UNLESS NOTED OTHERWISE,2x MUDSILL TO BE A4 ARCHITECTURAL DETAILS
OTHER AREAS THAT WATER MAY INTRUDE.WINDOWS AND DOORS SHALL BE REQUIRED VENTILATION AREA SHALL BE A MINIMUM INSTALLED FLUSH WITH THE INSIDE FACE OF A5 CABINET DETAILS
` INSTALLED PER MANUFACTURER INSTRUCTIONS. OF 3 FT.ABOVE EAVE VENTS.THE BALANCE OF FOUNDATION WALL AT JOIST BEARING POINTS TO A6 TALL FOUND.WHERE REQ'D
REQUIRED VENTILATION SHALL BE PROVIDED AT
ACCEPT JOIST HANGERS.VERIFY THAT THE S1 FOUNDATION PLAN 10.SINGLE STORY CONDITION U.N.O.ON S2 SHEET:NAIL ALL TOP PLATES TOGETHER W/ THE EAVES. MUDSILL IS SQUARE AT ALL CORNERS. S2 SHEAR WALL PLAN
10d NAILS @ 12"O.C.AND AT SPLICES W/10d NAILS @ 6"O.C. LAP SPLICES A MIN.OF 7. ATTACH THE MUDSILL TO THE FOUNDATION WITH S3 ROOF FRAMING PLAN
48"TYPICAL,NAIL ALL BOTTOM PLATES TO FLOOR SHEATHING AND MUDSILL W/(2) 6. PROVIDE A MIN.ROUGH OPENING 22"x30"ATTIC 1/2"x10"ANCHOR BOLTS WITH NUT AND STANDARD
S4 STRUCTURAL DETAILS
10d NAILS EA.STUD BAY,NAIL ALL FLOOR SHEATHING W!8d NAILS @ 6"O.C.EDGE ACCESS PANEL WITH A TIGHT-FITTING/SELF- WASHER @ 6 FT.O.C.AND WITHIN 12"OF EACH END S5 STRUCTURAL DETAILS
AND 12"O.C.FIELD,EXTERIOR STUDS MUST BE SPACED AT 16"O.C. CLOSING DOOR.DOOR SHALL BE BACKED WITH OF THE PLATE SECTION. E1 ELECTRICAL PLAN N L
INSULATION IF LOCATED ABOVE HEATED SPACE. 7.1. IN SDC D0,D1,D2,USE 1/4"x3"x3"PLATE L•L I-
11.TWO STORY CONDITION U.N.O.ON S2 SHEET:NAIL ALL TOP PLATES TOGETHER W! VERIFY ACCESS LOCATION WITH OWNER AND WASHER ON EACH BOLT. W W
10d NAILS @ 12"O.C.AND AT SPLICES W/10d NAILS @ 5"O.C.ON FIRST FLOOR,6"O.C. PLANS. 7.2. WHERE ANCHOR BOLTS ARE MISSED USE A \ Uj
ON SECOND FLOOR.LAP SPLICES A MIN.OF 48"TYPICAL,NAIL ALL BOTTOM PLATES 1/2"x 8"TITAN HD MECHANICAL ANCHOR BOLT.
TO FLOOR SHEATHING AND MUDSILL W/(2)10d NAILS EA.STUD BAY,NAIL ALL FLOOR 7• SHEATH ROOF PER IBC CASE 1(STAGGERED
SHEATHING W1 8d NAILS @ 6"O.C.EDGE AND 12"O.C.FIELD,EXTERIOR STUDS MUST PANELS UNBLOCKED)FASTEN PANELS W/8d NAILS 8. REBAR IS REQUIRED IN SDC D0,D1,D2 PER IRCDESIGN ENGINEER O
BE SPACED AT 16"O.C. @ 6"O.C.EDGE AND 12"O.C.FIELD.DO NOT R403.1.3.A MIN.(1)#4 REBAR IN FOOTINGS.AND(1) 4�G� J
STAPLE. #4 REBAR WITHIN 12"OF TOP OF WALL. 'eoy S�ABDELOUAHAB(Wahab)Abrous,Ph.D.,P.E. U �+
12.ALL BEDROOMS ARE TO HAVE AN EGRESS WINDOW WITH A MIN.WIDTH OF 20" ANDA cmC 5Q\a[•50\\\0\2� HiLine Homes Inc.
MIN.HEIGHT OF 24"WITH A MINIMUM NET CLEAR OPENING NOT LESS THAN 5.7 FT'. g, UNLESS NOTED OTHERWISE,TOE-NAIL ALL GABLE 9. THE FOUNDATION IN THIS PLAN IS DESIGNED��l.E n �t�OC\�OsebuC\a����f `,t�(Design&Engineering Department
END TRUSSES WITH(2)10d NAILS @ 16"O.C.INTO PRESCRIPTIVELY,BUT THE CONNECTION?, �, ,.r �v\ E CCCOCs Washington State License Number:36110
13.SEE SHEET"E1"FOR EXHAUST FAN,SMOKE AND CARBON MONOXIDE DETECTORS, TOP PLATES. THE FOUNDATION TO THE MUDSIILL'N EN.GINE&ED�gk0'Q a-nA o�CO�QCe��dah regonStateState
License Number:P-14132
E
AND ELECTRICAL FIXTURE LOCATIONS. FOR RESISTING LATERAL LOADS AS OUTLINED-IN GOC 01 a0t �`'
TOE-NAIL EACH END THE DESIGN CRITERIA ON`SHEET�'CS" C�a,-. kbe ��51(253)770-2244 x 132 Alternate x129
14.CABINET,PLUMBING FIXTURE,AND DOOR ROUGH OPENINGS ARE CRITICAL 9 OF TUNLR SSOAT BEARING WALLS TED W/(2)10d NAILS AND (h0 r5 ynb°tQc Q`ynwabrous@hilinehomes.com
DIMENSIONS.TAKE CARE TO VERIFY THAT THESE DIMENSIONS ARE FRAMED 10.FOOTINGS AND STEM WALLS)SHALLIBE AS'OC" Liv HILINE HOMES
FASTEN WITH TRUSS CLIPS PER PLAN. i� '�� '�,
ACCURATELY. FOLLOWS(UNLESS NOTED OTFiERWISE)��J S t�, 0`� 11306 62ND AVENUE
�� ��,p Z„� t,.
10.1. BELOW ONE STORY PORTIONS OFcA'BUILDING: "� �y�+ �1�(-(3 PUYALLUP WA,98373
15.SMOKE ALARMS ARE REQUIRED IN ALL SLEEPING ROOMS,OUTSIDE ALL SLEEPING 10.ASPHALT SHINGLES MUST COMPLY WITH WIND FOOTINGS=12"WIDE. `1 '\��Og U aC\- ` �� OVAFIA[; (253)770-2244 ext.129
SPEED SITE CONDITIONS AND BE SEALED IN ICP 0 OE �� �O
AREAS,AND ON EACH ADDITIONAL STORY OF THE DWELLING.SYSTEM MUST BE STEM WALLS=6"THICK. yk1� � F \\'%S/
ACCORDANCE WITH ASTM D 7161 OR UNSEALED IN 10.2. BELOW TWO STORY PORTIONS-•FN'V O //I O
INTERCONNECTED IN SUCH A WAY THAT ALL ALARMS SOUND WHEN ONE IS ACCORDANCE WITH ASTM D 3161.IRC R905.2 '�OF A'BUILDING: _C' %;� PLAN: 2112
ACTUATED.IRC R314 STEOMIWALLS156WTDH CK f,�0`la\�ak2 / DATE: 10/30/13
11.MIN.4"STEP FLASHING AT WALL/ROOF 4 p, JOB#: 10105948
16.AN APPROVED CARBON MONOXIDE ALARM E REQUIRED OUTSIDE EACH SLEEPING CONNECTIONS AND TURNED OUT AT THE BOTTOM 11.INHERE REQUIRED PER IRC R406.1,FOUNDATION
AREA I THE IMMEDIATE VICINITY OF THE BEDROOMS AND ON EACH LEVEL OF THE TO DIRECT WATER AWAY FROM THE WALL.IRC WALLS SHALL BE DAMP PROOFED AROUND THE 1 361 I O
DWELLING.IRC R315.1 R905.2.8.3 ENTIRE PERIMETER USING A METHOD THAT IS ��� Oic•- \� V�
APPROVED BY THE BUILDING DEPARTMENT. ` /IS/
12.PROVIDE DRIP EDGE AT EAVES AND GABLES OF �� / UNAL V (CS
SHINGLED ROOFS. "; �i9/
74'-0"
22' 0" 6'-32" 24'-52" T-9" 13'-6" w E
x --- 0
FRAME BOTH WALLS AT 42" 5'-31" w
1 2 6'-6" 7'-0" , d
5'-9 2 AND CAP W/2 LAYERS OF 7/s" 1 0
A O.S.B. FOR PLANT SHELF. 6,-0„ 2'-92" o
A2
606101 S.G.D. 303 HS `
S.G. 403 HS G. 60 40 HS ��7 J
5'SOAK. NOTE:SOLID BLOCK O
—ADW S ( TUB
RANGE W/ ' J q ALL THREE SIDES OF 2
tD UTIL. 00 DINING "' HOOD - STIR -ZD THE SOAKING TUB
cO ATO) ~ BAT AT 21"O.C.
SOLID CORE 1 3g" MIN. VAULTED
W/WEATHER STRIP 28 o KITCHEN
��t
SURFACE WARM WALL W/%z" -iN 4'-0 " �F 4 MSTR. BDRM.
G.W.B.ALL GARAGE WALL/ R&S iv cp � `iN
� S N
CEILING SEPARATIONS. icR Q ppc8-
" (n m
N = 1 "HALF- 2'-9-" - 20 2 - U) rn
WALL---,,,, (o
" PLAIT SHELF 1 s J d N
�VAU 1 8'-31" N 5'-9-" 3'-111 4 LU �r rn
_2--co 2 -10" 2 2
WHOLE HOUSE FAN W/ Q J w
GARAGE TIMER SWITCH AND 2s IF 12a WIC q� AN 06 d ON w o
VENTED WINDOWS INJ_,� ~ Q N z (0
HABITABLE ROOMS. gDRXi Co AGS `"
Q v
IRC§ M1507.3.4 LAUND. uVT� ® a R&S 0
16'x T OHD(MTL. NON-INSUL.) GREAT N FURRED 2'7.. "� 26 N R&S o U O
2x6 WALL W � _ co d
3'-0" 16'-0" 3'-0" ROOM 1s xs 1.. 5° iN v
VAULTED ob � 4'-62 6'-9" o
40 2a 50 00
j ENT �ca to BAT ji �N BDRM. 4
c„, o
30
t o
� 04
A 80 50 HS FIX - � 1., "' NN
A2 i G. N �6 3-52 11'-0" --- L.L
50 O Z
10'-5" -9" O J
I / - 2'-7" J a-
24'-0" _o LL
BDRM 2BDRM 3
Ito N
�0 0
�v
50 50 HS 50 50 HS HILINE HOMES
11306 2ND AVENUE
AREA SUMMARY 7'-6" 5'-9" 7'-3" 7'-6" PUYALLUPWA,983 3
(253Y)770-2244 ext.129
MAIN FLOOR AREA 2112 SQ. FT. 13'-3" 14'-9"
PORCH 96 SQ. FT. 28'-0" PLAN: 2112
GARAGE 528 SQ. FT. DATE: 10/30/13
= HOSE BIB JOB#: 10105948
S.G. = SAFETY GLAZING
FLOOR PLAN Al
1/8"= V-0"
ATTACH ROOF SHEATHING TO TRUSS
TOP CHORDS W/8d NAILS @ 6"O.C.
EDGE AND 12"O.C.FIELD.
2x4 BLOCKING.ATTACH U7
ROOF SHEATHING TO E
BLOCK W/8d NAILS v E
@ 6"O.C. ' W _
SOLID BLOCKING AT
E
BEARING.ATTACH TO G
TRUSSES W/(2)10d c N
a,a
NAILS EA.TRUSS. J J o
CANTILEVERED TRUSSES ATTACH SOLID
@ 24"O.C. BLOCKING TO TOP
PLATES W/(2)10d NAILS 0
J"CHANNEL OR 1x EA.BLOCK
TRIM PIECE TO FINISH 2
ATTACH LP SOFFIT TO
PLAIN LP SOFFIT ATTACHED TO BLOCKING W/8d NAILS
BOTTOM CHORD W/8d NAILS @ @ 6"O.C.
12"O.C.CAULK ALL SEAMS.
NOTE:AT PORCH GABLE ENDS
2x4 TRIM OVER LP SOFFIT AT WHERE GABLE IS SHEATHED
END OF CANTILEVERED PORCH. MAKE SURE THAT THE SHEATHING
ATTACH TO TRUSS BOTTOM IS NOT EXPOSED To BELOW BY ROOF SHEATHING REQUIREMENTS
CHORD W/(2)10d NAILS EA. LAPPING THE LP SOFFIT OVER
TRUSS. SHEATHING EDGE. Ground snow load M
co
CANTILEVERED TRUSS MAX.40 psf MAX.70 psf lBeyond 70 psf (n
7/16"O.S.B. 15/32"O.S.B. 5/8"O.S.B. J Z Q co
1 ATTACHMENT AT SHEARWALL/ NTS g
CANTILEVERED TRUSS Q J>_ w06 �Ow �
RIDGE VENTING Q 040
SOLID BLOCK AT BEARING. (U �
ATTACH TO TRUSSES W/(2)
10d NAILS EA.TRUSS.ATTACH MANUFACTURED PRE- MIN. ROOF MATERIALS:
SOLID BLOCKING TO TOP ENGINEERED TRUSSES @ COMPOSITION SHINGLES CLASS
PLATES W/(2) 10d NAILS EA. 24"O.C. 'B' 15#FELT OVER APA RATED
BLOCK. 24/0 SHEATHING.
BAFFLE BOARD
W/1"AIRSPACE 2x VENT BLOCK
� z z
5/8"G.W.B. (OR)%2"SAG \ 1 TYPICAL O
RESISTANT(TABLE R702.3.5) 0
/ A4 EAVE END J
R-49 INSULATION – — U
4'0" TYPICAL INTERIOR WALL:
CANTILEVERED "SIMPSON" HURRICANE (2)2x4 TOP PLATES OVER 2x4 TYPICAL EXTERIOR WALL: 'w
ATTACH LP SOFFIT TO v
CLIPS H1 (OR)H2.5A UP STUDS @ 19.2"O.C.W/%2' 2x6 TOP PLATES OVER 2x6 J
TO 85 mph, EXPOSURE'C'. G.W.B. EA.SIDE OVER 2x4
STUDS @ 16"O.C. OVER 2x6
BOTTOM CHORD W/8d aim BOTTOM PLATE OVER
�
NAILS @ 6"O.C. EDGE H10 ONLY BEYOND 85 mph. BOTTOM PLATE�
AND 12"O.C. FIELD R-23 INSULATION W/VAPOR STRUCTURAL RATED 3/4"
BARRIER PAINT OVER 3/a"T&G SUB-FLOORING.APA SHEATHING.WRAP HOUSE W/
RATED 48/24 GLUED& AN APPROVED WATER
SHEET ROCK NAILED 9%2'I-JOISTS @ HILINE HOMES
R-30 FLOOR 19.2"O.C. RESISTANT BARRIER(R703.2)
11306 62ND AVENUE
PUYAL373
INSULATION / \ 253)77 -2 44 t.12
\ (253)770-2244 ext.129
PLAN: 2112
BLACK 6 MIL. POLY VISQUEEN
TYPICAL 2 ( ( DATE: 10/30/13
PONYWALL VAPOR BARRIER THROUGHOUT (S4 I CRAWL SPACE. I JOB#: 10105948
BUILDING SECTION A-A -- 5 TYPICAL
S5 FOUND. q
1/4"= V-0" HL
J
n ul
E
V
Ld
o
DEDEDDEEI DODD
sm cl
1
EDDEDEE G 0 0
E]
BRICK VENEER FRONT ELEVATION
W/CAP
118"= V-0"
SITE ADDRESS: Q N
00
U) co
-2X6 BARGE BD. co
LOT 22 U) m
—-------- W/METAL DRIP EDGE U)
<
PORT ANGELES, WA 98382 Lu C/)
<
06 00
<cq c'j
z co
12
. .......... -------
5 c/)
RIGHT ELEVATION ------
1/8"= 1'-0"
NOTE:
ADDRESS MUST BE LOCATED
ON THE HOUSE WHERE IT IS EASILY
SEEN FROM THE MAIN ACCESS ROAD LEFT ELEVATION 1x4 WINDOW TRIM w <
(OWNER RESPONSIBILITY) >
X ui
FIBERGLASS COMP.SHINGLES w _j
CLASS"B" MIN. RIDGE VENTING w
A7-
-----------_. HILINE HOMES
1130662ND AVENUE
PUYALLUP WA,98373
------- (253)770-2244 ext.129
------------
x 6 CORNER TRIM
CEMENT LAP SIDING ❑ PLAN: 2112
DATE: 10/30/13
FINISHED GRADE BY ❑ JOB#.- 10105948
OWNER SHALL SLOPE S.G.
AWAY FROM BUILDING 6"
IN 10'-0" MIN. ------- A3
REAR ELEVATION
MFR. TRUSSES @ 24" O.C.
2x VENT BLOCKING W/BORED INSULATION
HOLES & INSECT SCREENS. CONT. BEHIND JOISTS @ CONTINUOUS Ln
E
NAIL W/8d NAILS @6" O.C. "T"WALLS 19.2"O.C. ° "
THROUGH ROOF SHEATHING. TRIMMER U.N.O. 2x4 PLATES w N
TOE-NAIL BLOCKING TO EACH 2x4 STUD PONYWALL E J
TRUSS W/(1) 10d NAILS EA. _
END OF BLOCK. (INTERIOR WALL)
C r
J
BUILT UP
2x6 DRYWALL HEADER I
BACKER z
FASTEN BLOCKING
TO TOP PLATE W/ 2x6 STUDS @ 16"O.C. 2'-0"
"SIMPSON" RBC EXTERIOR WALLSN MIN.
FOOTING Q co
CLIPS @24"O.C. FILL
ALL NAIL HOLES. 1'-4" (n co
TRUSS TAILS INTERIOR WALL DETAIL <
SIMPSON 'H CLIPS J :0:-) cfl
PER S3 SHEET. FILL � TYPICAL NTS 3 CRAWL ACCESS DETAI w �, �
ALL NAIL HOLES. TYPICAL NTS Q>- w
2x6 TOP PLATE 06 00 w
& EAVE END DETAIL ~ ¢� Z Q
-TYPICAL o NTS U O
07 a_
FULLY INSULATED 2x6 DOUBLE
CORNER TOP PLATE
INSULATION J
Q
2x6 VERTICAL
2x4 DRYWALL D U)
BACKER OR 2x6 FLAT —�
CLIPS DRYWALL EXT. U Q
2x6 STUDS @ 16" SHEATHING w �.
O.C. EXTERIOR W
WALLS = Q
4 EXT. CORNER DETAIL 6 GABLE END HEADER DETAIL U
TYPICAL NTS TYPICAL NTS
Q
2x6 DOUBLE
TOP PLATE
HILINE HOMES
11306 62ND AVENUE
PUYALLUP WA,98373
R-10 RIGID (253)770-2244 ext.129
INSUL.
2x NAILER PLAN: 2112
DRYWALL —�� DATE: 10/30/13
JOB#: 10105948
EXT.
4x HEADER SHEATHING
U.N.O. ��
5 INSUL. HEADER DETAIL
TYPICAL NTS
FILLER
4'-0" 4'-6" 1'-0" 1'-3" 1'-0" 1'-0" V-3" 9" 2'-6" 1'-3" T-3"
LV E
0 E
' W d E
E .9
0 2
N
J L
a 1-
To
N N F- ----7 ■i I
I I
RANGE
HOOD
Lj
I I
I I
D D D O REF. i 00
Cn �
0 o W Cna � so
N
SINK M , �� C.6m
DW g E ANG Q ti
06 o o Lu
FL I_j <N (D
- Q
T L
2'-9" 2'-0" 3'-0" 1'-0" 1'-0" 2'-0" 2'-0" 1'-0" 2'-6" 1'-3" T-42 O
KITCHEN 2 KITCHEN
NTS NTS
W J
Z_ Q
m �-
0 W
a a oElN
FILLER FILLER FILLER FILLER HILINE HOMES
2'-0" 1'-0" 2'-0" 2'-3" 1'-3" 2'-3" 11306 62ND AVENUE
21" 2'-0" 21' PUYALLUP WA,98373
�45° MSTR. BATH BATH (253)770-2244 ext.129
FILLER FILLER PLAN: 2112
KITCHEN
4 NTS NTS DATE: 10/30/13
3 NTS NOTES: JOB#: 10105948
1. CABINET MAKER TO VERIFY ALL CABINET DIMENSIONS ON SITE.
2. THIS DRAWING IS AN APPROXIMATE REPRESENTATION FOR THE
CABINET DESIGN. ACTUAL CABINET UNITS MAY VARY PER A5
CABINET MAKER.
3. FOR Y CEILING OPTION -ADD 6" OF HEIGHT TO UPPER CABINETS.
NOTE:
ATTACH MAIN LEVEL FRAMING TO FOUNDATION W/ 1/2"x 7" 1. FOR SEISMIC DESIGN AREAS D0, D1 AND D2,WHERE UNBALANCED BACKFILL DOES
HILTI QB-TZ ATTACHED TO A 1/2" COUPLING, ATTACHED TO NOT EXCEED 4'-0"AND FOUNDATION WALL DOES NOT EXCEED 4'-6" IN HEIGHT,
A 1/2"THREADED ROD OR ASTM A 307 BOLT, ATTACHED TO FOUNDATION WALL IS PERMITTED TO BE 6"THICK W/ (1)#4 CONTINUOUS REBAR
A "SIMPSON" LTT20B HOLD DOWN ATTACHED TO MAIN WITHIN TOP 12" OF FOUNDATION WALL. (IRC SECTION R404.1.4.2, EXCEPTION 3.) � E
FLOOR FRAMING PER MANUF. INSTRUCTIONS. USE A 2" W
WASHER AND 1/2" NUT.
2. WHERE THERE IS MORE THAN 4'-0" OF UNBALANCED BACKFILL WALLS MUST BE c 2
LATERALLY RESTRAINED AT THE TOP AND BOTTOM (OR) DESIGNED AS A RETAINING d
WALL. Zi
ATTACH UPPER WALLo
f
❑ _ _a
FRAMING TO LOWER 3. FOUNDATION SUB-CONTRACTOR IS REQUIRED TO VERIFY STEP LOCATIONS WITH 3O
WALL FRAMING W/ CONTRACTOR AND BUILDING DEPARTMENT. _
p' "SIMPSON" CS14 STRAP
FOR (U.N.O. ON SHEET S2). 4. ALL CRIPPLE WALLS ARE TO BE SHEATHED AND NAILED PER SHEARWALL DETAILS
ATTACH SHEATHING
RIMBOARD EDGES AT SOLE PLATE AS SHOWN ON PLANS. WHEN PLANS CALL FOR A HOLDOWN AND THERE IS A
OPTION AND TOP PLATES W/8d CRIPPLE WALL THEN THERE MUST BE A CONNECTION MADE FROM THE FOUNDATION
TO THE BOTTOM PLATE OF THE MAIN LEVEL WALL USING A 1/2" COUPLER ATTACHED
NAILS @ 4" O.C.
TO A THREADED ROD OR AN ASTM A 307 BOLT. CONNECT TO MAIN LEVEL WALL Q 00
co I
DETAIL A L BOTTOM PLATE WITH A"SIMPSON" LTT20B HOLD DOWN (SEE DETAIL"A"). WHEN A 00
TOE-NAIL RIMBOARD W/ RIMBOARD IS USED, ATTACH WALL ABOVE AND BELOW WITH "SIMPSON" CS14 J cn Q (D
10d NAILS @ 12" O.C. STRAP, U.N.O. ON SHEET S2 (SEE DETAIL "B"). LU U): � rn
>- ti
DETAIL B U.N.O. 5. THE FOUNDATION IN THIS PLAN IS DESIGNED PRESCRIPTIVELY. THE MUDSILL 06 o O w
ATTACH O.S.B. CONNECTION IS ENGINEERED. WHERE 1/2"ANCHOR BOLTS ARE MISSED PER PLAN <N cli z co
SHEATHING TO TOP TOP FLANGE JOIST HANGER TO HANG OFF OF THEN A REPLACEMENT IS ALLOWED PER S1 GENERAL NOTES. THIS PLAN IS
PLATE W/8d NAILS PER THE DOUBLE TOP PLATE OF THE CRIPPLE WALL. INTENDED TO SHOW THE SHEAR TRANSFER FROM THE MAIN LEVEL WALLS TO THE O o
SHEARWALL PLAN ATTACH HANGER PER MANUF. SPECIFICATIONS. PRESCRIPTIVE FOUNDATION USING CRIPPLE WALLS THAT DO NOT EXCEED SIX FEET 0 D..
NAILING. NAIL TOP IN HEIGHT.
PLATES TOGETHER W/ � SEE DETAIL 'A'ABOVE FAME ALL EXTERIOR 2x STUDS 2x BOTTOM PLATE
10d NAILS @ 12" O.C. WHEN HOLD DOWNS ARE WALLS AT CRIPPLE @ 16" O.C. 3
SPLICES ARE TO BE A _ REQUIRED WHERE A WALL PERIMETERS 4"T&G PLYWOOD
MIN. OF 48"ATTACHED CRIPPLE WALL IS USED. PER DETAIL 1 ON S4 SUBFLOORING z
W/ 10d NAILS @ 6" O.C. O J
SHEATHING LAPS W
TOP PLATE I Z
O
ATTACH O.S.B. Q Q
SHEATHING TO - m W �\ LLJ
MUDSILL W/ 8d NAILSIL
/ J
PER SHEARWALL i 's is Q
PLAN NAILING. i U —
o w
J 0-
ATTACH MUDSILL \ s sJ v Q J HILINE HOMES
TO FOUNDATION / n� Q v U Q 11306 62P AVENUE 9837
WITH�"ANCHOR PUY 770-2 44 t.129
(253)770-2244 ext.129
BOLTS SPACED PERPLAN. SEE Sl ;�,� i Q III-III-IIIIIIIII=1III-III
=111= = =111= —III PLAN: 2112
GENERAL NOTES N —� = _— — _ - —III ' DATE: 10/30/13
= 11i =1III=1 _�=1 =1 1= i =1 =1 =1 =1 =1 =111IIIIIIIII-IIIA i ' JOB#: 10105948
1 1III=1 I I=1 I I=1 I I=1 I I=1 I I-III=III-IIIIIIIIIIII=1 I I=1 I IIIIIIIIII1 I IIi1�_��i=til-Iii
=1 STEPPED FOUNDATION / CRIPPLEWALL A6
SHEAR TRANSFER TO PRESCRIPTIVE FOUNDATION NTS
73'-11"
Lo E
22'-0" 51'-11" E
STOOP BY OWNER START POINT ' W 00)41(
m
A MAX.7%"RISE, 1 TYPICAL 9%2" I-JOIST @ o
A2 MIN.36"SQUARE — FOUNDATION 19.2"O.C. _
a�
(IRC,R311.3) _ _ _ _ _ _ _ _ 2
— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —
— — — — — — — — — — — —
— — — — — — — — — —
15„ T O
Q 1 15'-1.016
0" _-___OFFSET T
JOISTS BEAR ON 2 x 4 o
PONY WALL OVER 12"x 6"
QAT
K
4"CONC. SLAB ON CONTINUOUS FOOTINGCOMPACTED GRAVEL FILL. Ll- - - - - - - - - - - - - - - - - - - — �SLOPE
DOR. SLAB DN.2"TO 4 INTERIOR — CN
w(" I S4 SHEARWALL — — — — — — — (n rn
MIL VISQUEEN VAPOR — U) (o
I BARRIER THROUGHOUT °O W (n:0:-) 37 N
I ' CRAWL SPACE. LAP w
2 TYPICAL SPLICES 12"MIN. Q
S4 PONYWALL r J� �S o O w
24"x24"x12" Q v Z coo
CONC. 1� 1'
� - - - — — — — — — — - - — — — - - _ I— QFOOTING — — — — — — — — —— — — — — — — <— — _ TYPICAL3O
J = 9%2'I-JOISTS-19.2"O.C. CRAWL ACCESS A4 (n ILINo B B TOP FLANGE JOIST #4 REB FT o
rn 1 THESE FIGS.
16'-3" B iv L
ANGER. MUDSILL
-10" ROUGH OPENING 2'-11"I LUSH TO INSIDE r LOAD BEAR.
L — ZJ — —
L — — -- - - - - - rZ
STOOP BY OWNER — - — — — — 10'-11,2" �iN O
A MAX.7 4„RISE, L�> _
—— 0O
A2 MIN.36"SQUARE *- INTERIOR 4 / — — _lr — N
(IRC,R311.3) SHEARWALL S5 Z
22'-0" 24'-0" 17'-0" V. `—— EDQ Q
O
o
ATTENTION LL
I
_"SIMPSON"STHD10 HOEDOWN
SEE DETAIL 4 ON SHEET S4. — — — — — — — — — — — — — — — —
A (TOTAL=2) �— — — — — — — — -
16"x 18"SCREENED 11LINE HOMES
�(—(aft 11306 62ND AVENUE
_"SIMPSON"STHD10 HOLDOWN FOUNDATION VENT PUYALLUP WA,98373
B SEE DETAIL 3 ON SHEET S5. (TMP) 2T-1 T' wAlIA13 (253)770-2244 ext.129
(TOTAL=4) ,0 WAS/yNr'FpG PLAN: 2112
FOUNDATION FOOTING WIDTHS DATE: 10/30/13
VARY ON THIS PLAN.PLEASE _
VERIFY FOOTING WIDTHS. JOB#. 10105948
r
16110_ :�
FOUNDATION PLAN ass,"`',`�;���� si
1/8"= 1'-0"
1 2 3 4
E
U]
A UE
i A2 i i ' wo
E
oCD
=
M I c N
J L
8
GARAGE SIDE S4 I I UTIL. KITCHEN 31 ® MSTR. 3:1
DINING BAT
� ® MSTR.
BDRM.
GARAGE I
I I
Q N
� co
coco
� Q (o
��III WIC w W 04
04
JII
n--in
Q ( ( GREAT UJ
LAUND. m' iii a - - - - - - oZS �ow `r
L!__iu
ROOM — — Q CN Q
- � 1--
L) cl�
- BITB B ENTRY
B BDRM. 4
BATH
GENERAL LATERAL NOTES _ _ D O.S.B.THIS -�
4"EDGE NAILING SIDE
1. NO CHANGES SHALL BE MADE WITHOUT THE CONSENT J
OF THE GENERAL CONTRACTOR AND BUILDING
DEPARTMENT. q
A2 4 INTERIOR � Z
2. O.S.B.WALL SHEATHING 7/16"MINIMUM ONLY FORS5 SHEARWALL N Q
EXTERIOR SHEARWALLS.NAIL SHEARWALLS PER LL
EXTERIOR SHEARWALL DETAIL 1 ON SHEET S4 U.N.O. BDRM 2 BDRM 3 Q
3. NAIL ALL TOP PLATES TOGETHER WITH 10d NAILS @ 12" W
O.C.AND AT SPLICES W/10d NAILS @ 6"O.C. LAP
SPLICES A MIN.OF 48"TYPICAL, NAIL ALL BOTTOM LEGEND (n
PLATES TO FLOOR SHEATHING AND MUDSILL W/(2) 10d =SHEARWALL SEGMENT
NAILS EACH STUD BAY.
4. FASTEN ALL O.S.B.SHEARWALLS W/8d NAILS @ 6"O.C. _"SIMPSON"STHD10 HOLDOWN SEE 0-o'(1 3
EDGE AND 12"O.C. FIELD.U.N.O. AT GARAGE PORTALS: HILINE HOMES
FASTEN ALL OSB SHEARWALLS W/8d NAILS 4"O.C. A DETAIL 4 ON SHEET S4. (TOTAL=2) 11306 62ND AVENUE
@ pvAHAti PUYALLUP WA,98373
\ \VAS//�4 253 770-2244 ext.129
O
EDGE AND 12"O.C. FIELD U.N.O. �v dip ( )
_ n
5. WHERE PLAN REQUIRES SHEATHING TO BE ATTACHED "SIMPSON"STHD10 HOLDOWN SEE PLAN: 2112� /p ��' G
TO THE MUDSILL ON THE PONY WALLS PERDETAIL 3 ON SHEET S5. (TOTAL=4) a
13
SHEARWALL DETAILS, PONYWALL STUDS MAY BE B 0` DATE:
OFFSET TO ALIGN W/ONE EDGE WHEN A 2x6 MUDSILL JOB#: 10010591059 488
IS USED.THIS WILL ALLOW FOR THE REQUIRED
MUDSILL ATTACHMENT. SEE PLANS FOR THIS <sS/UNALL�L,`�
REQUIREMENT.
SHEAR WALL PLAN S2
Lo
"SIMPSON"HURRICANE CLIPS H-1 (OR) TYPICAL o ;
U E
A H-2.5 A UP TO 85 mph, EXPOSURE'C'. 12"RIPPED ROOF
P I.B.C.CASE 1 ROOF ' w a
A2 H-10 ONLY BEYOND 85 mph. SHEATHING LAYOUT SHEATHING AT GABLE E J
4x10 D.F.#2 I 14x10b:F#2
If 'I .4 CHORD'TRIMMERS -ice--1
I \12TR,TRIMMERSS \ ,_o =a
L_..------------
I 4 ATTACH'.
_ � ► t 1 - - _
i P.E. MANUF.TRUSSES @a 24,"O.C. $I
I i ,
I I i
I P.E;. MANUF.I SCISSOR T SE -24"O.C.
"� It S RUS - -
SUF P.E.iMANUF.TSES --
"
RII GE;VENTING
- @ 24O. �
4';O.CI
5:12' PLANT SHELF W/2 4. Q C4
L YEF2S OIF 7/ts" O.S.B. - - 0000
ABOVE PANTRY. I � Q
J
RO
j (RIDGE VENTING r- 15.12 CUT SHEATHING BACK w IP
1"EA.SIDE OF PEAK r W
6"�L J;ul! FOR VENTING Q W v
®r _ — N U� O
101 III Q(NZcO
CHORD L �) I - F- < M
S4 (ATTACH; DROP DOWN
— I U
3;%2"x13%2"I G.04B. BOTTOM CHOR I
z 2x6 OVERFRAMING
- -- .� SOLID BLOCKING II LU z
LU W _1
AT BEARING IM S i'. - 0 >
6 _ CES W U SI'M P _I N" H-10 I _
I' ( - -O C9- O.
3%2"x9" G.L.B. _ S,BEARING N - (5)PLA ES 'n
- -- r-- -.- - RUSS BEA ! Gi (D
A 12 TRIMMERS( - -
_ Z
A2 CANTILEVERED TRUSSESD.F. -I CC
PLAIN LP -, - G
- - - - �
ZGIRDER TRUSS _ _ _ _ -_ _ Z
"SIMPSON"H-10 UP TO z 4 SOLID "SIMPSON"H-10 UP TO <85 mph EXP.C- -- — - - - - -- - -�-- S5 -BLOCKING--- 85 mph EXP.C- LL J
BEYOND 85 mph ADD LLi BEYOND 85 mph ADD
LEGEND H2.5A TO EXTERIOR __..._... __ _.__._ - - -_ H2.5A TO EXTERIOR O
® = CUT OUT FOR VENTING. KITCHEN=8"x8"FOR O
5:12
HOOD VENT. BATHROOMS=4"x4",AND UTILITY n/
ROOM=6"x6"FOR WHOLE HOUSE FAN. I LL
I
• = GUTTER DOWNSPOUT LOCATION I
= NON-STRUCTURAL FULL HEIGHT WALL FOR SHEET
ROCK ATTACH.ATTACH STUDS TO TRUSS BOTTOM 2x4 LOOK- H 306 62 HOMES
OUTS 48" vAl'IAI3 11306 62ND AVENUE
CHORD W/(2) 10d NAILS AT EA. FRAMED UP STUD. O.C.-TYP. `�0 w,�si ���ro "' PUYALLUP WA,98373
�O 7/,yam (253)770-2244 ext.129
C
a
= INTERIOR LOAD PLAN: 2112
BEARING WALL DATE: 10/30/13
36110-- c� JOB#: 10105948
SS�ONAL
ROOF FRAMING PLAN S3
1/8"= 1'-0"
NAIL TOP PLATES SOLID BLOCKING AT BEARING NOT
�. REQUIRED WHEN JOISTS ARE
TOGETHER W/10d - '=t `HUNG ON THE MUDSILL U.N.O.
NAILS @ 12"O.C. 2x MUDSILL TO HANG OVER
DOUBLE TOP PLATES FOUND.APPROXIMATELY YZ". (n
FLOOR JOIST
BIRD BLOCKING. (OR) W/A MINIMUM 48"LAP ATTACH SHEATHING TO p H
AT SPLICES. MUDSILL W/8d NAILS 6"O.C. u o
CONT. BLOCKING. @
NAIL THROUGH ROOF I 2X4 WALL @ 19.2" O.C. ATTACH JOISTS TO (U.N.O.ON S2 SHEET). W aNi
SHEATH.W/8d NAILS STUDS DIRECLTY TOP PLATES W/(2) E
BELOW JOISTS TYP. 1 O NAILS AT EA.
@ 6"O.C. I SHEATH PONY BEARING POINT TYP. C N
WALLS AT INTERIOR ENGINEERED CONNECTION-
NAIL MIN.7/6"WALL 2x TREATED PLATE ATTACH MUDSILL W/1/2"x10" Zi c
SHEATHING) 8d SHEAR WALLS ONLY (OR)2x PLATE OVER
ANCHOR BOLT W/STD. _
12"x6"CONTIN. VAPOR BARRIER ii ,_G o
COMMON NAILS 6' I I I FOOTING. WASHER @ 6 FT O.C. DO, U
@ Y2"ANCHOR BOLTS @ ON St SHEET.(IN SDC D0, - �
O.C. EDGE AND 12"O.C. 6 O.C.W/3"x3"x1/4" D1,D2 USE 1/4"x3"'x3" . _ _
FIELD (U.N.O.ON$2 WASHER U.N.O. PLATE WASHER).EMBED
SHEET BOLT A MINIMUM 7 INCHES
PONY WALL DETAIL (DO NOT COUNTERSINK.)
2x STUDS @ TYPICAL NTS SILL CONNECTION
16"O.C. I 3 HUNG JOIST NTS
FASTEN BLOCKING TO TOP
BOTTOM PLATE I I PLATE W/"SIMPSON"RBC
O.S.B. CLIPS @24"O.C.FILL ALL
2x MUDSILL STOOD NAIL HOLES. 'Q 04
2x VENT BLOCKING W/BORED HOLES - V) M
2 10d NAILS UPRIGHT &INSECT SCREENS.NAIL Bd NAILS@ 0)
( ) I• (OR) 6"O.C.THROUGH ROOF SHEATHING. - � �
rn
EACH STUD BTOE-NAIL BLOCKING TO EACH Q
BLOCKE I TRUSS W/(1)10d NAILS EA. CD
N
END OF BLOCK. n 1Ed1
t�j >-
ENGINEERED I• I uJ
CONNECTION Q
FROM MUDSILL TO BA17E R SPACE INSULATION
FOR C-4
KJ Q O W �
FOUNDATION.SEE PRESCRIPTIVE' II VENTILATION, Q N Z 0
CONNECTION =JI FOUNDATION- ' oJl "SIMPSON TRUSS CLIPS PER Q
DETAILS ON S4 ° S3 SHEET.FILL ALL NAIL O
(2)2X6 TOP PLATES MIN. HOLES.BEND CLEAR _
10
( '
48"LAP.ATTACH W/10d BOTTOM CHORD.D.(WHERE /� �� v O
EXTERIOR S H EA RWAL L
1 NAILS @ 12"O.C. REQUIRED AT VAULTS)
TYPICALLY AND AT 6"O.C.
OVER PRESCRIPTIVE FOUNDATION WALL NTS AT LAPS. EXTERIOR WALL o
TYP.WALL SHEATHING: STUDS @ 16"O.C. (2)2X6 TOP PLATES W/
CONT.TRUSS CHORD. SHEATH W/MIN.7/16"O.S.B. MIN.48"LAP.ATTACH W/
TOENAIL TO WALL W/ ATTACH TO WALL STUDS 1 O NAILS @ 12"O.C. DIAPHRAGM
6"O.C. I" STOOD UPRIGHT OR TYPICALLY AND AT 6" CONNECTION
10d NAILS
QO BLOCKED W/8d NAILS @ 6" O.C.AT LAPS. DETAIL PER PLAN
O.C.EDGE AND 12"O.C.
TO TRUSS CHORD& FIELD.SHEATHING MUST BE J
UNLESS.WALL SHEATHING;
PLATES I I ATTACHED TO MUDSILL.SEE LESS NOTED OTHERWISE, EXTERQ
NAIL TOP PLATES OR WALL
REQUIR METS.ADDITIONAL STUDSI@ 16 O.C.
^
R2 SHEET
FOR SHEATH BOTH SIDES W/MIN. /1/ U
• 1/2"G.W.B.ATTACH TO WALL \J J
TOGETHER W/10d STUDS STOOD UPRIGHT OR
12"O.C. I BLOCKED W/TYPE S OR INSULATION PER
NAILS J
@ ATTACH ALL BOTTOM TYPE W DRYWALL SCREWS THE A2 SHEET
O.S.B.(GARAGE SIDE PLATES W/10d NAILS @ 4"EDGE AND 4"FIELD.
@ B"O.C. FIRE TAPE ALL SEAMS.SEE
OF WALL) ATTACH W/ O.S.B. FLOOR SYSTEM: THE S2 SHEET FOR FLOOR SYSTEM:
8d NAILS @ 6"EDGE& STOOD 3/4"MIN.T&G SUBFLOOR ADDTIONAL REQUIREMENTS. 3/4"MIN.T&G SUBFLOOR D w
12"FIELD. U.N.O.ON GLUED AND NAILED TO GLUED AND NAILED TO
( UPRIGHT JOIST w/8d @ 6"D.C. JOIST w/8d @ 6"D.C. Q
S2 SHEET EDGE&12"O.C.FIELD. HOLDOWN
(OR) EDGE 8 12"O.C.FIELD.
CONNECTIONS MAYBE
2x STUDS FLOOR JOISTS PER PLAN FLOOR JOISTS PER PLAN 1
BLOCKED REQUIRED.SEE THE S2 `^
@ 16"O.C. ( @ 19.2"O.C- SHEET FOR TYPE AND @ 19.2"O.C. v)
"SIMPSON"STHD10 LOCATION. �+!
HOLDOWN INSULATION PER ATTACH G.W.B.
HOEDOWN.ATTACH CONNECTION�S2
THE A2 SHEET. SHEATHING TO BOTTOM
PER MANUF.SPECS. REQUIRED.SPLATE AND MUDSILL W/
I E
SHEET FOR TYPE AND TYPE S OR W SCREWS
BOTTOM PLATE I LOCATION. 41 4"O.0.EDGE AND 4"O.Cl 1 rl—f14-13 HILINE HOMES
FIELD. 1 1 11306 62ND AVENUE
2x MUDSILL "n aln ( Alln(� �1/� PUYALLUPWA,98373
2 10d NAILS EA. i _ �h GARAGE—' ( X114 SEE GARAGE Q` Q�'WAS///�y �0 (253)770-2244 ext.129
( ) II I SLAB _ f - 1 FOUNDATION '%
STUD BAY DETAIL FOR SIZE PLAN: 2112
ENGINEERED �--SEE HOUSE
EBAR
ENGINEERED i i CONNECTION- I III 1 FOUNDATION ENGINEERED 1 1 AND IREM
_ II.
CONNECTION- 1 I REQUIREMENTS. DATE: 1 0/30/13
CONNECTION SEE FOUNDATION I - I DETAIL FOR SIZE _
(I SEE FOUNDATION ( I 1
, DETAIL. AND REBAR DETAIL.
NTS. JOB#: 10105948FROM MUDSILL TO REQUIREME3G110PRESCRIPTIVE FOUNDATION
FOUNDATION. SEE
cl
CONNECTION �SS/UNALL140,
DETAILS ON S4 ( —
S H EARWALL DETAIL ---- S4
L� EXTERIOR WALL FRAMING G GARAGE FIRE WALL FRAMING
GARAGE/HOUSE SEPARATION WALL NTS 5 TYPICAL WALL FRAMING SECTION NTS V GARAGE/HOUSE SEPARATION WALL NTS
SIMPSON STHD10 JOISTS HUNG TO FOUNDATION WALL JOISTS HUNG TO FOUNDATION WALL
FLOOR SYSTEM: ATTACHMENT PER 2x BORATE TREATED MUDSILL
3/4"MIN.T&G SUBFLOOR GLUED AND SHEARWALL (OR)2X PRESSURE TREATED
ATTACHMENT NAILED TO JOIST w/8d @ 6"O.C.EDGE& DETAILS
PER SHEARWALL 12"O.C. FIELD. FLOOR JOISTS PER PLAN 4"CONCRETE SLAB OVER N E
DETAILS @ 19.2"O.C.HUNG W/TOP FLANGE JOIST ENGINEERED COMPACTED GRAVEL FILL u o
HANGERS. CONNECTION- 1 w
ENGINEERED ATTACH MUDSILL W/ Z E
CONNECTION- ((—tt( ( _
ATTACH MUDSILL 1/2"x10"ANCHOR g I� ( c o
W/1/2"x10"ANCHOR — BOLT W/STD. co SLOPE OVAI IA(3
2x BORATE TREATED MUDSILL WASHER @ 6 FT O.C. j REBAR REQUIREMENTS: �� 09
BOLT W/STD. RAS _.
WASHER @ 6 FT Z (OR)2X PRESSURE TREATED
LINO ON S1 SHEET. 6"IN r t' �� 1� USE(1)#4 HORIZ. BAR WITHIN ��,� �Y OG sm D o
O.C.HERLINO ON S1 Z (IN SDC D0,D1,D2 Z ^ �� �` 11`111, 12"OF TOP OF STEM WALL. �✓^'T'
SHEET. (IN SDC D0, = REBAR REQUIREMENTS: USE 1/4"x3"x3" =III �� �1 _1111! WHERE A CONSTRUCTION y ac O =I OO
SLOPE 'f USE(1)#4 HORIZ. BAR WITHIN PLATE WASHER). N )I ^ �I11 _111_ JOINT EXISTS USE(1)#4 VERT. +
D1, D2 USE J 12"OF TOP OF STEM WALL. EMBED BOLT A r I II 111 111' REBAR @ 48"W/STANDARD J�
1/4"x3"x3"PLATE 111 1
6"IN {�� °1� WHERE A CONSTRUCTION MINIMUM 7 INCHES I al° x_111--_ 11 HOOK. EXTEND 14"MIN.INTO ✓r 36110, g,
WASHER). EMBED Z — Z JOINT EXISTS USE 1 #4 VERT. (DO NOT III �� STEM WALL.(IRC R403.1.3) OF 4'4'/STIi -��
BOLT A MINIMUM 7 =III 'I < O • 1�= �S
INCHES(DO NOT ivy REBAR @ 48"W/STANDARD COUNTERSINK.) �p I�f S�UNALN
HOOK.EXTEND 14"MIN. INTO m
COUNTERSINK.) = j� eo USE(1)#4 CONT. - �-
STEM WALL.(IRC R403.1.3) REBAR _ _ Q N
USE(1)#4 CONT. �, ° IN FOOTING 6" -1 I I- 00
N FOOTING REBAR ° •J° _ 6 MIL POLY VAPOR BARRIER. DRAINAGE SYSTEM 12" U) co
— c� PLACE THROUGHOUT CRAWL
WHERE REQUIRED PER _j Q CD
DRAINAGE SYSTEM — — SPACE.LAP SEAMS 12"AND LOCAL CODES. HOME *FOOTING WIDTHS MAY VARY.SEE L1J u (co
_ EXTEND 12"UP WALL.DAMP ( rn
WHERE REQUIRED 6 - OWNER RESPONSIBILITY THE S1 SHEET FOR FOOTING SIZES. �
PER LOCAL CODES. 12" PROOF EXTERIOR FOUNDATION ) J J �
(HOME OWNERS WALLS.(IRC R408.2) GARAGE FOUNDATION DETAIL _ —
2 06 oOw0
RESPONSIBILITY) FOOTING WIDTHS MAY VARY.SEE Q N Z co
THE S1 SHEET FOR FOOTING WIDTHS. MAX.4'-6"WALL, MAX.4'-0" BACKFILL NTS Q
1 PRESCRIPTIVE FOUNDATION TRUSSES @ 24"O.C. 0
FOUNDATION DETAIL •� •� � o
MAX.4-6 WALL, MAX. 4'-0" BACKFILL NTS W/SOLID BLOCKING.
• PRESCRIPTIVE FOUNDATION ATTACH TO TOP
PLATES W/(2) 10d
BIRD BLOCKING OR TRUSS NAILS EA. BLOCK (OR)
BOTTOM CHORD. NAIL LADDER BLOCKING.
THROUGH ROOF SHEATH. ia — 1.7 — —I NAIL TOP PLATES J
W/8d NAILS @ 6"O.C.AT I I I � I° TOGETHER W/10d
I
EAVE ENDS I NAILS @ 12"O.C. O.S.B.
GARAGE HEADER W/ I I I III' STOOD L1-
MIN. 6"BEARING I TiO.S.B. (ONE SIDE OF I I UPRIGHT I J
NAIL TOP PLATES TOGETHERWALL)W/8d NAILS @ (OR)
W/ 10d NAILS @ 12"O.C. U.N.O. T7F1_5/' IIF 6"O.C. EDGE AND 12" I I BLOCKED
I I I I I I III° O.C. FIELD (U.N.O.ON
NAIL W/8d COMMON NAILS 4II
II° S2 SHEET)@ 4"O.C. EDGE AND 12"O.C. 2x STUDS @ 16"O.C.FIELD (U.N.O.ON S2 SHEET) IIII I
2x STUDS @ 16"O.C. I I IO•S°B• III. BOTTOM PLATE (n
(2) 10d NAILS EA.STUD BAY ( III I ILI I I° (2) 10d NAILS
ATTACH SHEATHING TO IMBLOCKEDPANELS I •I EA.STUD BAY
MUDSILL AND BOTTOM PLATES W/ I I I I°
8d NAILS @ 4"O.C. I I HILI
E HOMAVENUES
SOLID PUYALLUP WA,98373
"SIMPSON"STHD10 HOLDOWN. I I I BLOCKING (253)770-2244 ext.129
ATTACH PER MFR. SPECS.
iT
P.T. MUDSILLo IF IF TTACH PER P.T. 2112
11 1
Y2"x10"ANCHOR BOLTS a SHEARWALL O.S.B.
DATE: 10/30/13
W/%4"x 3"WASHER ~---- „-20 I�ETAIL 1 ON S4. JOB#: 10105948
#4 HORIZONTAL REBAR 1 z FOOTING W/#4 REBAR°@ S/W
3 SHEARWALL DETAIL (:�) SHEARWALL DETAIL S5
SIMPSON STHD10 ATGARAGE NTS INTERIOR SHEARWALL NTS
PERPENDICULAR TO JOISTS
WP
U3 E
f O ;
w v,
1 __� ' z
S o
tJ C
rr-
� I
�j
CLG 1 /
CLG
OUTLET
tLINE
O
:V
GFII Q N
co
L`--11 r^
I,——in TK I V J 00
1I /
01 — — — — — — J co <
L__iu
O GFI (� d > N
- -
�� w�'
WHOLE HOUSE FAN W/ O ti
TIMER SWITCH AND ® �� 06 0 o Lu
/ VENTED WINDOWS IN Q N Z I
/ HABITABLE ROOMS. _ / �— T Q
IRC§M1507.3.40
/ { // \
WP \ ' I (n
ELECTRICAL NOTES — •
1. SMOKE DETECTORS SHALL BE 110v. HARD WIRED WITH BATTERY
BACKUP AND SHALL BE INTERCONNECTED. OWNER SHALL BE // \ Q
RESPONSIBLE FOR SMOKE DETECTORS IF A MONITORED FIRE o-- / U
SYSTEM IS REQUIRED. z
2. ELECTRICAL CONTRACTOR SHALL COORDINATE LOCATION OF �--
PANEL AND METER WITH CONTRACTOR. U
3. ELECTRICAL CONTRACTOR SHALL PROVIDE HEAT-LOSS W
CALCULATIONS(OR) FOLLOW THE PRESCRIPTIVE PATH ELECTRIC SYMBOLS -j
REQUIREMENTS FOR SIZING HEATING EQUIPMENT. $ LIGHT SWITCH SURFACE MNT. LIGHT w
4. ELECTRICAL CONTRACTOR SHALL CONFORM TO ALL LOCAL AND QD 110 V. DUPLEX OUTLET RECESSED DOWN LIGHT
STATE CODES. (D 220 V. OUTLET ® EQUIPMENT CONNECTION
5. EXACT PLACEMENT OF OUTLETS MAY VARY DEPENDING ON WPO WEATHERPROOF OUTLET t SMOKE/CARBON MONOXIDE DET. HILINE HOMES
CONSTRUCTION VARIABLES. GFI GROUND FAULT INTERRUPTER SMOKE DETECTOR P11306 62ND AVENUE
UYALLUP WA,98373
6.WHERE A DRYER IS VENTED TROUGH A FOUNDATION VENT THE RECESSED CAN LIGHTSMT7-1
(253)770-2244 ext.129
VENT MUST BE COMPLETELY SEALED TO PREVENT MOIST EXHAUST HEATER/FAN COMBO-V.T.O.
AIR FROM REENTERING THE CRAWL SPACE. Q TELEPHONE JACK PLAN: 2112
m� ZONED ELEC. HEATER 70 TELEVISION OUTLET + DATE: 10/30/13
Q EXHAUST FAN -V.T.O.
JOB#: 10105948
NOTE
1. EXACT LOCATIONS OF ELECTRICAL FEATURES SUCH AS SWITCHES,
ELECTRICAL PLAN OUTLETS, LIGHTS, OPTIONS, ETC. MAY VARY PER BUILD AREA AND
El
ELECTRICAL CONTRACTOR.
1/8"= V-0" 2. EXACT LOCATIONS OF HVAC SUPPLY AND RETURN VENTS MAY VARY PER
BUILD AREA AND HVAC CONTRACTOR.