HomeMy WebLinkAbout1235 Columbia Street Address:
1235 Columbia Street
PREPARED 8/13/15, 9:43:28 INSPECTION TICKET PAGE 3
CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 8/13/15
------------------------------------------------------------------------------------------------
ADDRESS : 1235 COLUMBIA ST SUBDIV:
CONTRACTOR POWER TRIP ENERGY CORP PHONE (360) 643-3080
OWNER LAUREEN M AND ROY K MIELKE PHONE (907) 723-0179
PARCEL 06-30-00-5-3-0185-0000-
APPL NUMBER: 15-00000816 RES SOLAR PROJECT
------------------------------------------------------------------------------------------------
PERMIT: BSOL 00 BUILDING PERMIT - SOLAR
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED' RESULT RESULTS/COMMENTS
-------------------- ----------------- ------
BL99 01 8/13/15 BLDG FINAL
August 13, 2015 9:34:38 AM jlierly.
bobbie 360-643-3080
-------------------------------------- COMMENTS AND NOTES --------------------------------------
CITY OF PORT ANGELES
®i DEPARTMENT OF COMMUNITY&ECONOMIC DEVELOPMENT- BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES, WA 98362
Application Number . . . . . 15-00000816 Date 7/10/15
Application pin number . . . 868144
Property Address . . . . . . 1235 COLUMBIA ST
ASSESSOR PARCEL NUMBER: 06-30-00-5-3-0185-0000- REPORT SALES TAX 1�
Application type description RES SOLAR PROJECT
Subdivision Name . . . . . . On your State eXCISe fax form
Property Use . . . . . . to the City of Port Angeles
Property Zoning . . . . . . . RS7 RESDNTL SINGLE FAMILY.
Application valuation . . . . 14618 (Location Code 0502)
-----------------------------------------------------------------------------
Application desc
ROOF MOUNTED GRID TIES SOLAR ARAY
----------------------------------------------------------------------------
Owner Contractor
LAUREEN M AND ROY K MIELKE POWER TRIP ENERGY CORP
1235 COLUMBIA ST 83 DENNY AVE
PORT ANGELES WA 98362 PORT TOWNSEND WA 98368
(907) 723-0179 (360) 643-3080
Permit . . . . . . BUILDING PERMIT - SOLAR
Additional desc ROOF MOUNTED PV
Permit Fee . . . . 130.00 Plan Check Fee .00
Issue Date . . . 7/10/15 Valuation . . . . 14618 ( \�
Expiration Date 1/06/16
Qty Unit Charge Per Extension
BASE FEE 130.00
---- ----- -----'-------- V
Fee summary Charged Paid Credited Due
-------- ---------- ---------- -- _
Permit Fee Total 130.00 130.00 .00 .00
Plan Check Total .00 .00 .00 .00
i�
Grand Total 130.00 130.00 .00 .00
W
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized isnot commenced within.180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
BUILDING PERMIT INSPECTION RECORD
- PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS—
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-in
Water Line Meter to Bldg)
Gas Line
Back Flow/Water FINAL Date Accepted b
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall Interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall I Floor/Ceiling
MECHANICAL:
Heat Pum /Furnace/FAU/Ducts
Rough-In
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts FINAL Date Accepted b
MANUFACTURED HOMES:
Footing/Slab
Blocking&Hold Downs
Skirting
PLANNING DEPT. Separate Permit#s SEPA:
Parkin /Lighting ESA:
Landscaping SHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction- R.W. PW /En ineeriri 417-4831
Fire 417-4653
Planning 417-4750
Building 417-4815
T:Forms/Buildinq Division/Buildinq Permit
%M CITY OF PORT ANGELES
F7DEPARTMENT OF COMMUNITY&ECONOMIC DEVELOPMENT-BUILDING DIVISION
.�i 321 EAST 5TH STREET, PORT ANGELES,WA 98362
Application Number . . . . . 15-00000816 Date 7/10/15
Application pin number . . . 868144
Property Address _ . . . . . 1235 COLUMBIA ST
ASSESSOR PARCEL NUMBER: 06-30-00-5-3-0185-0000- REPORT SALES TAX
Application type description RES SOLAR PROJECT
Subdivision Name . . . . . . on your state excise tax form
Property Use to the City of Port Angeles
Property Zoning . . . . . . . RS7 RESDNTL SINGLE FAMILY
Application valuation . . . . 14618 (Location Code 0502)
------------------------------------
Application desc
ROOF MOUNTED GRID TIES SOLAR ARAY
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
LAUREEN M AND ROY K MIELKE POWER TRIP ENERGY CORP
1235 COLUMBIA ST 83 DENNY AVE
PORT ANGELES WA 98362 PORT TOWNSEND WA 98368
(907) 723-0179 (360) 643-3080
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT - SOLAR
Additional desc . . ROOF MOUNTED PV
Permit Fee . . . . 130.00 Plan Check Fee .00
Issue Date . . . . 7/10/15 Valuation . . . . 14618
Expiration Date . . 1/06/16
Qty Unit Charge Per Extension
BASE FEE 130.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 130.00 130.00 .00 .00
Plan Check Total .00 .00 .00 .0
Grand Total 130.00 130.00 .00 .0
V/
v
Separate Permits are required forelectrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced,or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction. .�--
�oWEa.
Date Print Name Signature of Contractor or Authoriz Agent Signature of Owner(if owner is builder)
T:Forms]Building Division/Building Permit
CIT l oa �jGELES
SOP Cit}/Use
CITY OF �.
Permit#
W A S H I N G T O N, U. S.
Date Received:
321 E 5y Street Date Approved 17
Port Angeles,WA 9836
P:360-417-4817 F:360-417-4711
Email:permits0cilxypba.us BUILDING PERMIT APPLICATION
ProjectAddress: l "
T'ow 6�--Tp1 p E'"er Acvq Gd,- Phone: -64: -3090&FtcO 3ba
Prima Contact: -rGKN FL-i hba►•i(.r; Email: 16KN @ FL-W is XMP i�Cry3 =�Z4�►.CUM
Name
L.,�y -E,EN KO �l l i.IeE Phone Q 0 4 _ TT- 7--5— 00-c
f
Property Mailing Address , Email -{ T
Owner Z35 C—OU( t.F-ih ST, F—Y— "tt-S BAS Q 4tA -1L,C:aM
City p 5 State "{q Zip
i" t'C Vv rt %3 uZ
Name i �� Phone
Pow i�TRJ Q 'f co, �0) �tf3 3050
Address Email
Contractor
Information �'� DeNtA" k'4E �66M C �4�wt--k-rRtpF-P�`f'Com
City VOp-1 �6W is . N State VV/t zip I as(1 Z-
Contractors License# pa(,a E'R T E cl,4 a E Exp.Date: II r7 20 t,>
Legal Description:E/Z-aY IT Zoning: Tax Parcel# Project Value: (materials and labor)
,k� k LM 16,6� Ifp6C: vt Ps p5� 463ooa53oi�socc�. 1
Residential ® Commercial ❑ Industrial ❑ Public ❑
Permit Demolition ❑ Fire ❑ Repair ❑ Reroof(tear off/lay over) Q
Classification For the following,All out both ps of permit applications
(check New Construction ❑ Exterior Remodel ❑ Addition ❑ Tenant Improvement ❑
appropriate) Mechanical ❑ Plumbing ❑ Other ❑
Fire Sprinkler System? Irrigation System? Proposed Bathrooms Proposed Bedrooms i
Yes ❑ No O Yes ❑ No K Nle N 111- —
Project Description gaol Meut-t b, 6k-ltd-Tieb Q\/ PHoFaVct-tAic:s --SciA�,
�L�Cj7ZlG:
Is project in a Flood Zone: Yes ❑ NoW Flood Zone 'Type:
If in a Flood Zone,what is the value of the structure before proposed improvement? $
I have read and completed the application and know it to be true and correct. I am authorized to apply for
this permit and understand that it is my responsibility to determine what permits are required and to
obtain permits prior to work. I understand that plan review fees are not refundable after review has
occurred. I understand that I will forfeit review fees if I withdraw the application before the permit is
issued. I understand that if the permit is not picked up/issued within 28o days of submittal,the application
will be considered abandoned and the fees will be forfeited.
Date Print Name I Signatuae
` Cit yik�r 4t
Rec'd
HTE
ApPrv,
$130 Fee
Application and Checklist for Roof Mounted Residential Solar Panels
Project Information:
Property Owner Name: Laureen M&Roy K Mielke
Project Address: 1235 Columbia St, Port Angeles Phone:907-723-0179
Contractor Name: Power Trip Energy Co Registration#:POWERTE934QE
Contractor Phone: 360-643-3080
PV system Roof mounted grid tied 4.41 kW Mfg/model#of major equip:SolarWorld
description: 14 modules,6 kW inverter 315 watt Pro XL PV modules,SMA Sunny Boy
6000TL-US-22 inverter
Per WAC 51-51-2300,if the answer to the following questions is"yes"a building permit will be
issued for simple(10-15kw output) PV systems without further engineering.
Section M2302.2.1—Where solar panels are installed on roofs,the roof structure shall be deemed adequate to
support the load of the rooftop if all of the following are met:
Yes No
1. PV system is designed and proposed for a single family or detached accessory structure 0
2. The photovoltaic panels and modules and supporting structure shall be constructed of El
noncombustible materials or fire-retardant treated wood equivalent to that required for the
roof construction. The installation shall meet the requirements of the International Fire Code
as amended by WA State. PV modules are listed and labeled with a fire classification in
accordance with UL 1703
3. The PV system is designed foi'the wind speed of the local area and will be installed per the
manufacturer's specifications.
4. The ground snow load does not exceed 70 pounds per square foot.The PV system is designed O
for the wind speed of the local area,and will be installed per the manufacturer's specifications.
5. Total dead load of modules,supports,mountings,raceways and all other appurtenances weigh El
no more than four pounds per square foot. Enter total dead load of system (IbS/ft2). (2.64 PSI J
6. Supports for solar modules are installed to spread the dead load across as many roof-framing
members as needed to ensure that no point load exceeds fifty(50) pounds. Modules are
mounted no higher than 18"above the surface of the roofing to which they are affixed and do
not exceed the highest point of the roof unless'approved by the local jurisdiction.
NOTE: If site inspection indicates a concern that the roof structure is not adequate to
support the P\/module(s),engineering may be required prior to final of the permit.
As the property owner or authorized representative of the above listed property, I attest that all
information in this checklist is accurate to the best of my knowledge.
Applicant Signature: Date: 7/7/2015
Applicant Name(Please Print): 1 h . Fleming, Power Trip Energy Co
Relationship to Property Owner: Installation Contractor
T:\BUILDING\APPLICATION FORMS\SOLAR PERMIT CHECKLIST.DOC
i
10,
Proposed solar PV `` , �' - •�; Site Plan for
array on garage
Solar production
meter&AC disconnect - -- --- -
Ray & Laureen
on northeast wall
a Mielke at
Existing service i
entry& panel _
1235 Columbia St
Proposed solar PV
array on housey
Port Angeles
Approximate 4i
property line r i
Columbia St — z\�.
North liberty St
NORTH
Sunmodule;/ Pro-Series XL I SOLARWORLD
SW315-320 MONO REALVALUE
�LA
3o,N,tu
a
TUV Power controlled:
kTUVRhainlend t Lowest measuring tolerance in industry
O OOOOOZa`��
i PR
Every component is tested to meet .
3 times IEC requirements
i J
Designed to withstand heavy .
accumulations of snow and ice
I J
OSunmodule Plus:
Positive performance tolerance
' J
25-year linear performance warranty
and 10-year product warranty
J
World-class quality pwur a iee suis //��V a me=a.c.a,••..
`( Safery:exhtl,IEC 8:13a X3•('6^'� fe�etl
Fully-automated production lines and seamless monitoring of the process and mate- o e P•.�a,<„=�•<uoe g;P••a•.Ne,.<„u,•
•a�e..�y.,,,e...�awM aweeean<r.•a
rial ensure the qua litythat the company sets as its benchmark for its sites worldwide.
SolarWodd Plus-Sorting
Plus-Sorting guarantees highest system efficiency.SolarWorld only delivers modules AT4rF c us
that have greaterthan or equal tothe nameplate rated power. UL 1703
25-year linear performance guarantee and extension of product warranty to 10 years C
SolarWorld guarantees a maximum performance digression of 0.7%p.a.in the course ` ` G
of 25 years,a significant added value compared to the two-phase warranties common
i
in the industry,along with our industry-first 10-year product warranty.'
i
'in accordance with the applicable SolarWorld Limited Warranty at purchase.
www.sclarworld.com/warranty
Quality modules
made in Germany
�r
solarwortd.com
I
Sunmodule;/ Pro-Series XL SOLARWORLD
SIN 315-320 MONOi L PEAILVALIUIE�
PERFORMANCE UNDER STANDARD TEST CONDITIONS(STC)'
SW 315 SW320
Maximum power p,,,,, 315 Wp 320 Wp
Open circuit voltage V- 45.6 V 45.9 V
Maximum power point voltage Vmn 36.5 V 36.7 V
Short circuit current Iu 9.35 A 9.41 A
i
Maximum power point current Impp 8.71 A 8.78 A
Module efficiency 9m 16.03% 16.28%
Measuring tolerance(P„„)traceable to TUV Rheinland:+/-2%(TUV Power controlled) 'STC:1000W/m=,25'C,AM 1.5
PERFORMANCE AT 800 W/M',NOCT,AM 1.5
SW 315 SW320
Maximum power Pm,x 240.9 Wp 244.4 Wp
Open circuit voltage V� I 39.8 V 40.1 V
Maximum power point voltage VmPF 33.6 V 33.8 V
Short circuit current Ix 7.77 A 7.82 A
Maximum power point current ImPP ; 7.18 A 7.18 A
Minor reduction in efficiency under partial load conditions at 25'Cat 200 W/m',100%(+/-2%)of the STC efficiency(1000 Vilm')is achieved.
Ixr 1000 w/m= DIMENSIONS COMPONENT MATERIALS
800 W/m= Length 78.15 in(1985 mm) Cells per module 72
I- Width 38.98 in(990 mm) Cell type Mono crystalline
j 600 t4'/m= Height 1.81 in(46 mm) Cell dimensions 156 mm x 156 mm
aoo w/m= frame Clear anodized aluminum Font 3.2 mm Tempered glass
j _ Weight 49.6 lbs(22.5 kg) (EN 12150)
I 200 W/m=
100 W/m= THERMAL CHARACTERISTICS ADDITIONAL DATA
V. NOCT 46'C Powersorting -0 WP/+5 Wp
Modulevoltalle[VJ
TCI,r 0.042%/K J-Box IP65
-_31.6(955)
TCV_ -0.304%/K Connector KSK4
t
00.16(4) TCPmon -0.43%/K Module fire performance (UL 1703)Type 1
e
Ci
PARAMETERS FOR OPTIMAL SYSTEM INTEGRATION
o Maximum system voltage SC 11/NECNp9N W 4p°® 1000 V
I s Maximum reverse current 25 A
Load/dynamic load 113/64 psf(5.4/2.4 kN/m=)
o Number of bypass diodes 3
Operating range 40"C to+85"C
5� � @w
0.6 in.(15mm)
-*x4 1.8 in.(46mm)
I^0.98(25)
1.8(4G) 39.0(990)
I
i
All units provided are imperial.SI units provided in parentheses.
SolarWorld AG reserves the right to make specification changes without notice. 0.98 in.(25mm) SW-01-6056US 11-2014
Friday,January 31,2014 Snap rack-
SnapNrack
No r m a n 775 Fiero Lane,Suite 200
San Luis Obispo,CA 93401
"Series 100 Roof Mount" Cover Letter
cheel
To Whom It May Concem,
We have performed calculations for the 100 series roof mount PV system based on
Structural the information provided by SnapNrack. Included with this letter are the report and
calculations. We did the calculations in accordance with the 2012 IBC, ASCE 7-10,
2012 NDS, and guidelines stated in the Solar America Board for Codes and
Standards.
En g i n e e r Some of the components in the SnapNrack test data were used to determine the
capacity and section properties of materials. We collected the test data using the
5022 Sunrise Blvd. procedures outlined in the 2012 BC Chapter 17.
Fair Oaks,CA 95628
(916)536-9585
(916)536-0260(fax) We included the following types of load combinations and building parameters into
our calculations:
1989-2013
24 years of eacellence
• ASCE 7-10 wind speeds from 110 mph to 190 for B and C exposure
categories
• ASCE 7-10 Seismic Design Category E
• ASCE 7-10 Snow Loads up to 120 psf ground snow
• Buildings with mean roof heights up to 60 foot tih angles / roof pitches
Norman Scheel,S.E. from 0 degrees to 60 degrees.
1 FED AP BD+C
LEED AP Homes The calculations have also been completed in accordance with the 2006 IBC,2009
Fellmv—SEAOC IBC,and ASCE 7-05. To use the data contained in this packet for projects that are
Fellow-ASCE
E-mail:normCbnsse.com being evaluated to the older ASCE 7-05 wind speeds, refer to Appendix A for a
wind speed conversion chart. Find the ASCE 7-05 (IBC 2006/2009) wind speed in
Rob Coon
General Manager the Chart in Appendix A,identify the corresponding ASCE 7-10(IAC 2012)wind
E-mail:robcoon a>nsse.com speed value,and proceed with using the charts contained in this packet with the
Steve Smith P.E. adjusted wind speed value.
Project Manager
E-mail:stevesmith(a)nsse,com In our opinion, the mounting system, outlined by SnapNrack Series 100 PV
Mounting System Code Compliance Installation Manual, is acceptable and meets
Steven Cooksey the loading requirements as stated above. See the report and calculations included
CAD supervisor
E-mail:stcve(a'nssc.com with this letter for more information.
If there are any further questions,please contact Norm Scheel. N J. SC
Jacide Winslow �"'"Og WAS y�
Office Manager Y �
E-mail:iackic[mnssc&c u Norman Scheel PE, SE - O
LEED-AP BD+C,LEED-AP Homes M
Fellow S OC
Fellow A.C.E.
NO.
,PFaISTFR�o
EXPIRES DECEMBER 26, L.D
SnapNrack Series 100 nap CCK
Projectlnfo:
Dealer: Power Trio Energy Co Project Name: _ Mi Ike House
Create Date: 2015-07-07T14:03:52-0700 BOM#:1 35309
PV Module Data:
Module Brand SolarWorld Length 78.46 inches
Model SunModule Pro 315 Watt XL Width 39.4 inches
Depth 1.80 inches
Environmental Requirements: Weight 47.60 pounds
Topographic Condition Standard Rated power @ STC 0.00 W
Standard IBC 2012 Rail Color Clear
Snow Load 21-30 psf—STEM 'F- Racking Color Clear
Wind Speed 130 mph -xT6'H 3 ow cNECS'ItST
Rafter Spacing 24 inches
Roof Attachment Flashed L-Foot
System Style:
Rail Finish Black Anodized
End Clamp Type Universal
Grounding Method UL 2703 Listed
Micro Attachment Kits No
Edge Screen Trim? No if"Yes",4"or 8"screen? Screen Height0 inches
Tilt Up?l No
Sub-Arrays: UL2703 Yes Premium Alloy Rail No Bulk Customer No
Sub-Array
Sub-Array 122" Rail 162" Rail Rail Mid End Edge Roof
Modules Splices Clamps Clamps Screen Attachments
1 8 4 1 2 12 8 0 16
TOTALS 8 4 1 2 12 8 0 16
Page 1 of 3
Mieike Solar Racking
SnapNrack Series 100 Calculator
Proposed Bill of Materials
Part Number Description Qty
015-09816 SNAPNRACK,STANDARD RAIL SET, 1221N, BLACK,2 PC 2
015-09818 SNAPNRACK,STANDARD RAIL SET, 1621N, BLACK,2 PC 1
242-04015 SNAPNRACK,BONDING STANDARD RAIL SPLICE ASSEMBLY,BLACK 2
242-02052 SNAPNRACK, BONDING MID CLAMP ASSEMBLY, 1.50-2.00IN,CLEAR 12
242-02063 SNAPNRACK,BONDING UNIVERSAL END CLAMP ASSEMBLY 8
232-01023 SNAPNRACK RAIL END CAP,STANDARD, BLACK 8
242-02701 SNAPNRACK, BONDING L-FOOT KIT W/BASE AND FLASHING, BLACK L-FOOT 16
242-02101 SNAPNRACK,GROUNDING LUG ASSEMBLY 2
Total Weight: 5.52 lbs
System Total Weight: 430.00 lbs
Array Area=8 modules x(39.4"x 78.46"/144 sq.inch per sf)=172 sf
Pounds per Square Foot of Array=430 lbs/172 sf=2.5 psf tem 3 checklist
Pounds per attachment=430 lbs/16=26.9 lbs per attachment Item 6 checklist
Page 2 of 3
Mod ales Per S Array Pitch(degrees) 26 Sub-Array Modules 8
Row
Module 2 Building Height(ft) 15 Edge Screen(ft) 0
Rows
Orientation Portrait Attachment Spacing 72 Attachment Spacing 48 Array Power(kW) 0
inches Override inches
The maximum recommended rail span for this sub-array is 72 inches.The rail span for modules located in edge zones is reduced by 24 inches to 48 inches
Groep 1 Rail Group 2 Rail Group 3 Rail Group 4 Rail Group 5 Rail 122'Rail 162"Rail Row Mid Row End Row Attach- Module Rail
Length Length Length Length Length Qtv QtyClamps Clamps Splices ments Bonding Bondin
-199.00 2 1 8 4 2 10 0 1 QQ�Q
1`_9.20 2 0 4 4 0 5 0 1 0000❑
Sub-Array 4 1 12 8 2 16 0 2
Totals
Welke Solar Racking Page 3 of 3
SnapNrack Series 100 nap rack-
Project Info:
Dealer: Power Trip Energy Co Project Name: Mielke garage
Create Date: 2015-07-07T14:11:44-0700 BOM#:1 35311
PV Module Data:
Module Brand —SolarWorld Length 78.46 inches
Modell Sun—Module Pro 315 Watt XL Width 39.4 inches
Depth 1.80 inches
Environmental Requirements: Weight 47.60 pounds
Topographic Condition Standard Rated power @ STC 0.00 W
Standard IBC 2012 Rail Color Clear
Snow Load 21-30 psf—I�d*� Racking Color Clear
Wind Speed 130 mph—ZTrJ&% 3 oN "670F 01T
Rafter Spacing 24 inches
Roof Attachment Flashed L-Foot
System Style: _
Rail Finish Black Anodized
End Clamp Type �^ Universal
Grounding Method Lay-In-Lugs w/nut
Micro Attachment Kits No
Edge Screen Trim? No if"Yes",4"or 8"screen? Screen Height inches
Tilt Up? No
Sub-Arrays: I UL2703 No Premium Alloy Rail No Bulk Customer No
Sub-Array Sub-Array 122" Rail 162" Rail Rail Mid End Edge Roof
Modules Splices Clamps Clamps Screen Attachments
1 6 4 0 2 10 4 0 12
TOTALS 6 4 0 2 10 4 0 12
Page 1 of 3
Mielke Solar Racking
SnapNrack Series 100 Calculator
Proposed Bill of Materials
Part Number Description Qty
015-09816 SNAPNRACK,STANDARD RAIL SET, 1221N, BLACK, 2 PC 2
242-04013 SNAPNRACK ASSEMBLY RAIL SPLICE,STANDARD,BLACK 2
242-02124 SNAPNRACK MID CLAMP W/CHANNEL NUT, 1.5-2.OIN,CLEAR 10
242-02215 SNAPNRACK ASSEMBLY, UNIVERSAL END CLAMP WAVE,REV 2 4
232-01023 SNAPNRACK RAIL END CAP,STANDARD,BLACK 4
242-92051 SNAPNRACK KIT, L FOOT W-BASE,COMPOSITION FLASHING, BLACK 12
051-03418 LAY-IN LUG AND LONG#10-32 SS SCREW AND NUT BAG OF 10-UL 1
Total Weight: 21.80 lbs
System Total Weight: 340.00 lbs
Array Area=6 modules x(39.4"x 78.46"/144 sq. inch per sf)=129 sf
Pounds per Square Foot of Array=340 lbs/129 sf=2.64 psf Item 5 checklist
Pounds per attachment=340 lbs/12=28.3 lbs per attachment Item 6 checklist
Page 2 of 3
i
Moeules Per
Array Pitch(degrees) 15 Sub-Array Modules 6
Row
Nodule 1 Building Height(ft) 13 Edge Screen(ft) 0
Rows
Orientation Portrait Attachment Spacing 72 Attachment Spacing 48 Array Power(kW) 0
inches Override finches
The maximum recommended rail span for this sub-array is 72 inches.The rail span for modules located in edge zones is reduced by 24 inches to 48 inches
Group 1 Rail Group 2 Rail Group 3 Rail Group 4 Rail Group 5 Rail 1 122"Rail 162'Rail Row Mid Row End Row Attach- Module Rail
Length Len th Length Length Leniffth I Qtvt Clam s Clamps 5 licez ments Bonding Bonding
238.401 4 10 4 12 _ 2 ❑QOQQO
�I Sub-Array 4 0 10 4 2 12 6 2
�! Totals
Mielke Solar Racking Page 3 of 3
ji
1?
it
'i
�i
,i
i
JI
1
CC^n_A y
Y 4 ata
Favjw TP6p (Enavgg (C®ep
83 Denny Ave
Port Townsend, WA 98368
(360) 643-3080
tvimw.powertripenergy.com
Lic # POWERTE964JN
July 7,2015
Pat Bartholick
Code Compliance Officer
321 E 5th Street
P.O.Bos 1150
Port Angeles, WA 98362
codecompliance@cityofpa.us
Dear Mr.Bartholick,
Enclosed please find a building permit and electrical permit for work to be done at 1235 Columbia St,Port Angeles for
Laureen&.Roy Mielke. Our company(Power Trip Energy)will be installing a 4.41 kW solar array on the southwest
roofs of their house&garage.
I am using the Application and Checklist for Roof Mounted Residential Solar Panels,same as the last permit.
Power Trip Energy will be happy to pay for the plan check fee by credit card as soon as you request payment. The
electrical permit fee will also be paid by Power Trip Energy with a credit card.
If you have any additional questions please do not hesitate to call the office at 360-643-3080.
Sincerely,
John Fleming,PE
Solar Engineer
Power Trip Energy
Attachments:
I —Application and Checklist for Roof Mounted Residential Solar Panels, site plan,& support documents
2—Electrical Permit Application&Electrical Line Drawing
1