Loading...
HomeMy WebLinkAbout1235 Columbia Street Address: 1235 Columbia Street PREPARED 8/13/15, 9:43:28 INSPECTION TICKET PAGE 3 CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 8/13/15 ------------------------------------------------------------------------------------------------ ADDRESS : 1235 COLUMBIA ST SUBDIV: CONTRACTOR POWER TRIP ENERGY CORP PHONE (360) 643-3080 OWNER LAUREEN M AND ROY K MIELKE PHONE (907) 723-0179 PARCEL 06-30-00-5-3-0185-0000- APPL NUMBER: 15-00000816 RES SOLAR PROJECT ------------------------------------------------------------------------------------------------ PERMIT: BSOL 00 BUILDING PERMIT - SOLAR REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED' RESULT RESULTS/COMMENTS -------------------- ----------------- ------ BL99 01 8/13/15 BLDG FINAL August 13, 2015 9:34:38 AM jlierly. bobbie 360-643-3080 -------------------------------------- COMMENTS AND NOTES -------------------------------------- CITY OF PORT ANGELES ®i DEPARTMENT OF COMMUNITY&ECONOMIC DEVELOPMENT- BUILDING DIVISION 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Application Number . . . . . 15-00000816 Date 7/10/15 Application pin number . . . 868144 Property Address . . . . . . 1235 COLUMBIA ST ASSESSOR PARCEL NUMBER: 06-30-00-5-3-0185-0000- REPORT SALES TAX 1� Application type description RES SOLAR PROJECT Subdivision Name . . . . . . On your State eXCISe fax form Property Use . . . . . . to the City of Port Angeles Property Zoning . . . . . . . RS7 RESDNTL SINGLE FAMILY. Application valuation . . . . 14618 (Location Code 0502) ----------------------------------------------------------------------------- Application desc ROOF MOUNTED GRID TIES SOLAR ARAY ---------------------------------------------------------------------------- Owner Contractor LAUREEN M AND ROY K MIELKE POWER TRIP ENERGY CORP 1235 COLUMBIA ST 83 DENNY AVE PORT ANGELES WA 98362 PORT TOWNSEND WA 98368 (907) 723-0179 (360) 643-3080 Permit . . . . . . BUILDING PERMIT - SOLAR Additional desc ROOF MOUNTED PV Permit Fee . . . . 130.00 Plan Check Fee .00 Issue Date . . . 7/10/15 Valuation . . . . 14618 ( \� Expiration Date 1/06/16 Qty Unit Charge Per Extension BASE FEE 130.00 ---- ----- -----'-------- V Fee summary Charged Paid Credited Due -------- ---------- ---------- -- _ Permit Fee Total 130.00 130.00 .00 .00 Plan Check Total .00 .00 .00 .00 i� Grand Total 130.00 130.00 .00 .00 W Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized isnot commenced within.180 days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder) T:Forms/Building Division/Building Permit BUILDING PERMIT INSPECTION RECORD - PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS— Building Inspections 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION: Footings Stemwall Foundation Drainage/Downspouts Piers Post Holes(Pole Bldgs.) PLUMBING: Under Floor/Slab Rough-in Water Line Meter to Bldg) Gas Line Back Flow/Water FINAL Date Accepted b AIR SEAL: Walls Ceiling FRAMING: Joists/Girders/Under Floor Shear Wall/Hold Downs Walls/Roof/Ceiling Drywall Interior Braced Panel Only) T-Bar INSULATION: Slab Wall I Floor/Ceiling MECHANICAL: Heat Pum /Furnace/FAU/Ducts Rough-In Gas Line Wood Stove/Pellet/Chimney Commercial Hood/Ducts FINAL Date Accepted b MANUFACTURED HOMES: Footing/Slab Blocking&Hold Downs Skirting PLANNING DEPT. Separate Permit#s SEPA: Parkin /Lighting ESA: Landscaping SHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE Inspection Type Date Accepted By Electrical 417-4735 Construction- R.W. PW /En ineeriri 417-4831 Fire 417-4653 Planning 417-4750 Building 417-4815 T:Forms/Buildinq Division/Buildinq Permit %M CITY OF PORT ANGELES F7DEPARTMENT OF COMMUNITY&ECONOMIC DEVELOPMENT-BUILDING DIVISION .�i 321 EAST 5TH STREET, PORT ANGELES,WA 98362 Application Number . . . . . 15-00000816 Date 7/10/15 Application pin number . . . 868144 Property Address _ . . . . . 1235 COLUMBIA ST ASSESSOR PARCEL NUMBER: 06-30-00-5-3-0185-0000- REPORT SALES TAX Application type description RES SOLAR PROJECT Subdivision Name . . . . . . on your state excise tax form Property Use to the City of Port Angeles Property Zoning . . . . . . . RS7 RESDNTL SINGLE FAMILY Application valuation . . . . 14618 (Location Code 0502) ------------------------------------ Application desc ROOF MOUNTED GRID TIES SOLAR ARAY ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ LAUREEN M AND ROY K MIELKE POWER TRIP ENERGY CORP 1235 COLUMBIA ST 83 DENNY AVE PORT ANGELES WA 98362 PORT TOWNSEND WA 98368 (907) 723-0179 (360) 643-3080 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT - SOLAR Additional desc . . ROOF MOUNTED PV Permit Fee . . . . 130.00 Plan Check Fee .00 Issue Date . . . . 7/10/15 Valuation . . . . 14618 Expiration Date . . 1/06/16 Qty Unit Charge Per Extension BASE FEE 130.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 130.00 130.00 .00 .00 Plan Check Total .00 .00 .00 .0 Grand Total 130.00 130.00 .00 .0 V/ v Separate Permits are required forelectrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced,or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. .�-- �oWEa. Date Print Name Signature of Contractor or Authoriz Agent Signature of Owner(if owner is builder) T:Forms]Building Division/Building Permit CIT l oa �jGELES SOP Cit}/Use CITY OF �. Permit# W A S H I N G T O N, U. S. Date Received: 321 E 5y Street Date Approved 17 Port Angeles,WA 9836 P:360-417-4817 F:360-417-4711 Email:permits0cilxypba.us BUILDING PERMIT APPLICATION ProjectAddress: l " T'ow 6�--Tp1 p E'"er Acvq Gd,- Phone: -64: -3090&FtcO 3ba Prima Contact: -rGKN FL-i hba►•i(.r; Email: 16KN @ FL-W is XMP i�Cry3 =�Z4�►.CUM Name L.,�y -E,EN KO �l l i.IeE Phone Q 0 4 _ TT- 7--5— 00-c f Property Mailing Address , Email -{ T Owner Z35 C—OU( t.F-ih ST, F—Y— "tt-S BAS Q 4tA -1L,C:aM City p 5 State "{q Zip i" t'C Vv rt %3 uZ Name i �� Phone Pow i�TRJ Q 'f co, �0) �tf3 3050 Address Email Contractor Information �'� DeNtA" k'4E �66M C �4�wt--k-rRtpF-P�`f'Com City VOp-1 �6W is . N State VV/t zip I as(1 Z- Contractors License# pa(,a E'R T E cl,4 a E Exp.Date: II r7 20 t,> Legal Description:E/Z-aY IT Zoning: Tax Parcel# Project Value: (materials and labor) ,k� k LM 16,6� Ifp6C: vt Ps p5� 463ooa53oi�socc�. 1 Residential ® Commercial ❑ Industrial ❑ Public ❑ Permit Demolition ❑ Fire ❑ Repair ❑ Reroof(tear off/lay over) Q Classification For the following,All out both ps of permit applications (check New Construction ❑ Exterior Remodel ❑ Addition ❑ Tenant Improvement ❑ appropriate) Mechanical ❑ Plumbing ❑ Other ❑ Fire Sprinkler System? Irrigation System? Proposed Bathrooms Proposed Bedrooms i Yes ❑ No O Yes ❑ No K Nle N 111- — Project Description gaol Meut-t b, 6k-ltd-Tieb Q\/ PHoFaVct-tAic:s --SciA�, �L�Cj7ZlG: Is project in a Flood Zone: Yes ❑ NoW Flood Zone 'Type: If in a Flood Zone,what is the value of the structure before proposed improvement? $ I have read and completed the application and know it to be true and correct. I am authorized to apply for this permit and understand that it is my responsibility to determine what permits are required and to obtain permits prior to work. I understand that plan review fees are not refundable after review has occurred. I understand that I will forfeit review fees if I withdraw the application before the permit is issued. I understand that if the permit is not picked up/issued within 28o days of submittal,the application will be considered abandoned and the fees will be forfeited. Date Print Name I Signatuae ` Cit yik�r 4t Rec'd HTE ApPrv, $130 Fee Application and Checklist for Roof Mounted Residential Solar Panels Project Information: Property Owner Name: Laureen M&Roy K Mielke Project Address: 1235 Columbia St, Port Angeles Phone:907-723-0179 Contractor Name: Power Trip Energy Co Registration#:POWERTE934QE Contractor Phone: 360-643-3080 PV system Roof mounted grid tied 4.41 kW Mfg/model#of major equip:SolarWorld description: 14 modules,6 kW inverter 315 watt Pro XL PV modules,SMA Sunny Boy 6000TL-US-22 inverter Per WAC 51-51-2300,if the answer to the following questions is"yes"a building permit will be issued for simple(10-15kw output) PV systems without further engineering. Section M2302.2.1—Where solar panels are installed on roofs,the roof structure shall be deemed adequate to support the load of the rooftop if all of the following are met: Yes No 1. PV system is designed and proposed for a single family or detached accessory structure 0 2. The photovoltaic panels and modules and supporting structure shall be constructed of El noncombustible materials or fire-retardant treated wood equivalent to that required for the roof construction. The installation shall meet the requirements of the International Fire Code as amended by WA State. PV modules are listed and labeled with a fire classification in accordance with UL 1703 3. The PV system is designed foi'the wind speed of the local area and will be installed per the manufacturer's specifications. 4. The ground snow load does not exceed 70 pounds per square foot.The PV system is designed O for the wind speed of the local area,and will be installed per the manufacturer's specifications. 5. Total dead load of modules,supports,mountings,raceways and all other appurtenances weigh El no more than four pounds per square foot. Enter total dead load of system (IbS/ft2). (2.64 PSI J 6. Supports for solar modules are installed to spread the dead load across as many roof-framing members as needed to ensure that no point load exceeds fifty(50) pounds. Modules are mounted no higher than 18"above the surface of the roofing to which they are affixed and do not exceed the highest point of the roof unless'approved by the local jurisdiction. NOTE: If site inspection indicates a concern that the roof structure is not adequate to support the P\/module(s),engineering may be required prior to final of the permit. As the property owner or authorized representative of the above listed property, I attest that all information in this checklist is accurate to the best of my knowledge. Applicant Signature: Date: 7/7/2015 Applicant Name(Please Print): 1 h . Fleming, Power Trip Energy Co Relationship to Property Owner: Installation Contractor T:\BUILDING\APPLICATION FORMS\SOLAR PERMIT CHECKLIST.DOC i 10, Proposed solar PV `` , �' - •�; Site Plan for array on garage Solar production meter&AC disconnect - -- --- - Ray & Laureen on northeast wall a Mielke at Existing service i entry& panel _ 1235 Columbia St Proposed solar PV array on housey Port Angeles Approximate 4i property line r i Columbia St — z\�. North liberty St NORTH Sunmodule;/ Pro-Series XL I SOLARWORLD SW315-320 MONO REALVALUE �LA 3o,N,tu a TUV Power controlled: kTUVRhainlend t Lowest measuring tolerance in industry O OOOOOZa`�� i PR Every component is tested to meet . 3 times IEC requirements i J Designed to withstand heavy . accumulations of snow and ice I J OSunmodule Plus: Positive performance tolerance ' J 25-year linear performance warranty and 10-year product warranty J World-class quality pwur a iee suis //��V a me=a.c.a,••.. `( Safery:exhtl,IEC 8:13a X3•('6^'� fe�etl Fully-automated production lines and seamless monitoring of the process and mate- o e P•.�a,<„=�•<uoe g;P••a•.Ne,.<„u,• •a�e..�y.,,,e...�awM aweeean<r.•a rial ensure the qua litythat the company sets as its benchmark for its sites worldwide. SolarWodd Plus-Sorting Plus-Sorting guarantees highest system efficiency.SolarWorld only delivers modules AT4rF c us that have greaterthan or equal tothe nameplate rated power. UL 1703 25-year linear performance guarantee and extension of product warranty to 10 years C SolarWorld guarantees a maximum performance digression of 0.7%p.a.in the course ` ` G of 25 years,a significant added value compared to the two-phase warranties common i in the industry,along with our industry-first 10-year product warranty.' i 'in accordance with the applicable SolarWorld Limited Warranty at purchase. www.sclarworld.com/warranty Quality modules made in Germany �r solarwortd.com I Sunmodule;/ Pro-Series XL SOLARWORLD SIN 315-320 MONOi L PEAILVALIUIE� PERFORMANCE UNDER STANDARD TEST CONDITIONS(STC)' SW 315 SW320 Maximum power p,,,,, 315 Wp 320 Wp Open circuit voltage V- 45.6 V 45.9 V Maximum power point voltage Vmn 36.5 V 36.7 V Short circuit current Iu 9.35 A 9.41 A i Maximum power point current Impp 8.71 A 8.78 A Module efficiency 9m 16.03% 16.28% Measuring tolerance(P„„)traceable to TUV Rheinland:+/-2%(TUV Power controlled) 'STC:1000W/m=,25'C,AM 1.5 PERFORMANCE AT 800 W/M',NOCT,AM 1.5 SW 315 SW320 Maximum power Pm,x 240.9 Wp 244.4 Wp Open circuit voltage V� I 39.8 V 40.1 V Maximum power point voltage VmPF 33.6 V 33.8 V Short circuit current Ix 7.77 A 7.82 A Maximum power point current ImPP ; 7.18 A 7.18 A Minor reduction in efficiency under partial load conditions at 25'Cat 200 W/m',100%(+/-2%)of the STC efficiency(1000 Vilm')is achieved. Ixr 1000 w/m= DIMENSIONS COMPONENT MATERIALS 800 W/m= Length 78.15 in(1985 mm) Cells per module 72 I- Width 38.98 in(990 mm) Cell type Mono crystalline j 600 t4'/m= Height 1.81 in(46 mm) Cell dimensions 156 mm x 156 mm aoo w/m= frame Clear anodized aluminum Font 3.2 mm Tempered glass j _ Weight 49.6 lbs(22.5 kg) (EN 12150) I 200 W/m= 100 W/m= THERMAL CHARACTERISTICS ADDITIONAL DATA V. NOCT 46'C Powersorting -0 WP/+5 Wp Modulevoltalle[VJ TCI,r 0.042%/K J-Box IP65 -_31.6(955) TCV_ -0.304%/K Connector KSK4 t 00.16(4) TCPmon -0.43%/K Module fire performance (UL 1703)Type 1 e Ci PARAMETERS FOR OPTIMAL SYSTEM INTEGRATION o Maximum system voltage SC 11/NECNp9N W 4p°® 1000 V I s Maximum reverse current 25 A Load/dynamic load 113/64 psf(5.4/2.4 kN/m=) o Number of bypass diodes 3 Operating range 40"C to+85"C 5� � @w 0.6 in.(15mm) -*x4 1.8 in.(46mm) I^0.98(25) 1.8(4G) 39.0(990) I i All units provided are imperial.SI units provided in parentheses. SolarWorld AG reserves the right to make specification changes without notice. 0.98 in.(25mm) SW-01-6056US 11-2014 Friday,January 31,2014 Snap rack- SnapNrack No r m a n 775 Fiero Lane,Suite 200 San Luis Obispo,CA 93401 "Series 100 Roof Mount" Cover Letter cheel To Whom It May Concem, We have performed calculations for the 100 series roof mount PV system based on Structural the information provided by SnapNrack. Included with this letter are the report and calculations. We did the calculations in accordance with the 2012 IBC, ASCE 7-10, 2012 NDS, and guidelines stated in the Solar America Board for Codes and Standards. En g i n e e r Some of the components in the SnapNrack test data were used to determine the capacity and section properties of materials. We collected the test data using the 5022 Sunrise Blvd. procedures outlined in the 2012 BC Chapter 17. Fair Oaks,CA 95628 (916)536-9585 (916)536-0260(fax) We included the following types of load combinations and building parameters into our calculations: 1989-2013 24 years of eacellence • ASCE 7-10 wind speeds from 110 mph to 190 for B and C exposure categories • ASCE 7-10 Seismic Design Category E • ASCE 7-10 Snow Loads up to 120 psf ground snow • Buildings with mean roof heights up to 60 foot tih angles / roof pitches Norman Scheel,S.E. from 0 degrees to 60 degrees. 1 FED AP BD+C LEED AP Homes The calculations have also been completed in accordance with the 2006 IBC,2009 Fellmv—SEAOC IBC,and ASCE 7-05. To use the data contained in this packet for projects that are Fellow-ASCE E-mail:normCbnsse.com being evaluated to the older ASCE 7-05 wind speeds, refer to Appendix A for a wind speed conversion chart. Find the ASCE 7-05 (IBC 2006/2009) wind speed in Rob Coon General Manager the Chart in Appendix A,identify the corresponding ASCE 7-10(IAC 2012)wind E-mail:robcoon a>nsse.com speed value,and proceed with using the charts contained in this packet with the Steve Smith P.E. adjusted wind speed value. Project Manager E-mail:stevesmith(a)nsse,com In our opinion, the mounting system, outlined by SnapNrack Series 100 PV Mounting System Code Compliance Installation Manual, is acceptable and meets Steven Cooksey the loading requirements as stated above. See the report and calculations included CAD supervisor E-mail:stcve(a'nssc.com with this letter for more information. If there are any further questions,please contact Norm Scheel. N J. SC Jacide Winslow �"'"Og WAS y� Office Manager Y � E-mail:iackic[mnssc&c u Norman Scheel PE, SE - O LEED-AP BD+C,LEED-AP Homes M Fellow S OC Fellow A.C.E. NO. ,PFaISTFR�o EXPIRES DECEMBER 26, L.D SnapNrack Series 100 nap CCK Projectlnfo: Dealer: Power Trio Energy Co Project Name: _ Mi Ike House Create Date: 2015-07-07T14:03:52-0700 BOM#:1 35309 PV Module Data: Module Brand SolarWorld Length 78.46 inches Model SunModule Pro 315 Watt XL Width 39.4 inches Depth 1.80 inches Environmental Requirements: Weight 47.60 pounds Topographic Condition Standard Rated power @ STC 0.00 W Standard IBC 2012 Rail Color Clear Snow Load 21-30 psf—STEM 'F- Racking Color Clear Wind Speed 130 mph -xT6'H 3 ow cNECS'ItST Rafter Spacing 24 inches Roof Attachment Flashed L-Foot System Style: Rail Finish Black Anodized End Clamp Type Universal Grounding Method UL 2703 Listed Micro Attachment Kits No Edge Screen Trim? No if"Yes",4"or 8"screen? Screen Height0 inches Tilt Up?l No Sub-Arrays: UL2703 Yes Premium Alloy Rail No Bulk Customer No Sub-Array Sub-Array 122" Rail 162" Rail Rail Mid End Edge Roof Modules Splices Clamps Clamps Screen Attachments 1 8 4 1 2 12 8 0 16 TOTALS 8 4 1 2 12 8 0 16 Page 1 of 3 Mieike Solar Racking SnapNrack Series 100 Calculator Proposed Bill of Materials Part Number Description Qty 015-09816 SNAPNRACK,STANDARD RAIL SET, 1221N, BLACK,2 PC 2 015-09818 SNAPNRACK,STANDARD RAIL SET, 1621N, BLACK,2 PC 1 242-04015 SNAPNRACK,BONDING STANDARD RAIL SPLICE ASSEMBLY,BLACK 2 242-02052 SNAPNRACK, BONDING MID CLAMP ASSEMBLY, 1.50-2.00IN,CLEAR 12 242-02063 SNAPNRACK,BONDING UNIVERSAL END CLAMP ASSEMBLY 8 232-01023 SNAPNRACK RAIL END CAP,STANDARD, BLACK 8 242-02701 SNAPNRACK, BONDING L-FOOT KIT W/BASE AND FLASHING, BLACK L-FOOT 16 242-02101 SNAPNRACK,GROUNDING LUG ASSEMBLY 2 Total Weight: 5.52 lbs System Total Weight: 430.00 lbs Array Area=8 modules x(39.4"x 78.46"/144 sq.inch per sf)=172 sf Pounds per Square Foot of Array=430 lbs/172 sf=2.5 psf tem 3 checklist Pounds per attachment=430 lbs/16=26.9 lbs per attachment Item 6 checklist Page 2 of 3 Mod ales Per S Array Pitch(degrees) 26 Sub-Array Modules 8 Row Module 2 Building Height(ft) 15 Edge Screen(ft) 0 Rows Orientation Portrait Attachment Spacing 72 Attachment Spacing 48 Array Power(kW) 0 inches Override inches The maximum recommended rail span for this sub-array is 72 inches.The rail span for modules located in edge zones is reduced by 24 inches to 48 inches Groep 1 Rail Group 2 Rail Group 3 Rail Group 4 Rail Group 5 Rail 122'Rail 162"Rail Row Mid Row End Row Attach- Module Rail Length Length Length Length Length Qtv QtyClamps Clamps Splices ments Bonding Bondin -199.00 2 1 8 4 2 10 0 1 QQ�Q 1`_9.20 2 0 4 4 0 5 0 1 0000❑ Sub-Array 4 1 12 8 2 16 0 2 Totals Welke Solar Racking Page 3 of 3 SnapNrack Series 100 nap rack- Project Info: Dealer: Power Trip Energy Co Project Name: Mielke garage Create Date: 2015-07-07T14:11:44-0700 BOM#:1 35311 PV Module Data: Module Brand —SolarWorld Length 78.46 inches Modell Sun—Module Pro 315 Watt XL Width 39.4 inches Depth 1.80 inches Environmental Requirements: Weight 47.60 pounds Topographic Condition Standard Rated power @ STC 0.00 W Standard IBC 2012 Rail Color Clear Snow Load 21-30 psf—I�d*� Racking Color Clear Wind Speed 130 mph—ZTrJ&% 3 oN "670F 01T Rafter Spacing 24 inches Roof Attachment Flashed L-Foot System Style: _ Rail Finish Black Anodized End Clamp Type �^ Universal Grounding Method Lay-In-Lugs w/nut Micro Attachment Kits No Edge Screen Trim? No if"Yes",4"or 8"screen? Screen Height inches Tilt Up? No Sub-Arrays: I UL2703 No Premium Alloy Rail No Bulk Customer No Sub-Array Sub-Array 122" Rail 162" Rail Rail Mid End Edge Roof Modules Splices Clamps Clamps Screen Attachments 1 6 4 0 2 10 4 0 12 TOTALS 6 4 0 2 10 4 0 12 Page 1 of 3 Mielke Solar Racking SnapNrack Series 100 Calculator Proposed Bill of Materials Part Number Description Qty 015-09816 SNAPNRACK,STANDARD RAIL SET, 1221N, BLACK, 2 PC 2 242-04013 SNAPNRACK ASSEMBLY RAIL SPLICE,STANDARD,BLACK 2 242-02124 SNAPNRACK MID CLAMP W/CHANNEL NUT, 1.5-2.OIN,CLEAR 10 242-02215 SNAPNRACK ASSEMBLY, UNIVERSAL END CLAMP WAVE,REV 2 4 232-01023 SNAPNRACK RAIL END CAP,STANDARD,BLACK 4 242-92051 SNAPNRACK KIT, L FOOT W-BASE,COMPOSITION FLASHING, BLACK 12 051-03418 LAY-IN LUG AND LONG#10-32 SS SCREW AND NUT BAG OF 10-UL 1 Total Weight: 21.80 lbs System Total Weight: 340.00 lbs Array Area=6 modules x(39.4"x 78.46"/144 sq. inch per sf)=129 sf Pounds per Square Foot of Array=340 lbs/129 sf=2.64 psf Item 5 checklist Pounds per attachment=340 lbs/12=28.3 lbs per attachment Item 6 checklist Page 2 of 3 i Moeules Per Array Pitch(degrees) 15 Sub-Array Modules 6 Row Nodule 1 Building Height(ft) 13 Edge Screen(ft) 0 Rows Orientation Portrait Attachment Spacing 72 Attachment Spacing 48 Array Power(kW) 0 inches Override finches The maximum recommended rail span for this sub-array is 72 inches.The rail span for modules located in edge zones is reduced by 24 inches to 48 inches Group 1 Rail Group 2 Rail Group 3 Rail Group 4 Rail Group 5 Rail 1 122"Rail 162'Rail Row Mid Row End Row Attach- Module Rail Length Len th Length Length Leniffth I Qtvt Clam s Clamps 5 licez ments Bonding Bonding 238.401 4 10 4 12 _ 2 ❑QOQQO �I Sub-Array 4 0 10 4 2 12 6 2 �! Totals Mielke Solar Racking Page 3 of 3 ji 1? it 'i �i ,i i JI 1 CC^n_A y Y 4 ata Favjw TP6p (Enavgg (C®ep 83 Denny Ave Port Townsend, WA 98368 (360) 643-3080 tvimw.powertripenergy.com Lic # POWERTE964JN July 7,2015 Pat Bartholick Code Compliance Officer 321 E 5th Street P.O.Bos 1150 Port Angeles, WA 98362 codecompliance@cityofpa.us Dear Mr.Bartholick, Enclosed please find a building permit and electrical permit for work to be done at 1235 Columbia St,Port Angeles for Laureen&.Roy Mielke. Our company(Power Trip Energy)will be installing a 4.41 kW solar array on the southwest roofs of their house&garage. I am using the Application and Checklist for Roof Mounted Residential Solar Panels,same as the last permit. Power Trip Energy will be happy to pay for the plan check fee by credit card as soon as you request payment. The electrical permit fee will also be paid by Power Trip Energy with a credit card. If you have any additional questions please do not hesitate to call the office at 360-643-3080. Sincerely, John Fleming,PE Solar Engineer Power Trip Energy Attachments: I —Application and Checklist for Roof Mounted Residential Solar Panels, site plan,& support documents 2—Electrical Permit Application&Electrical Line Drawing 1