Loading...
HomeMy WebLinkAbout1315 Dutch Drive Address: 1315 Dutch Drive PREPARED 12/02/16, 8:50:18 INSPECTION TICKET PAGE 2 CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 12/02/16 ------------------------------------------------------------------------------------------------ ADDRESS . : 1315 DUTCH DR SUBDIV: CONTRACTOR DUTCH DRIVE DEVELOPMENT LLC PHONE (360) 565-6269 OWNER : PA PARTNERS LLC PHONE PARCEL 06-30-01-8-0-0200-0000- APPL NUMBER: 15-00001174 RES NEW SFR ----------------------- --- PERMIT: BPR 00 BUILDING PERMIT - RESIDENTTAT• REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------ --------- BL1 01 5/23/16 JLL BLDG FOUNDATION FOOTING 5/23/16 AP May 23, 2016 9:16:49 AM jlierly. Todd 565-6269 May 23, 2016 4:07:23 PM jlierly. BL2 01 5/27/16 JLL BLDG FOUNDATION STEM WALL 5/27/16 AP May 27, 2016 8:39:52 AM jlierly. ERIC 808-5647 May 27, 2016 4:14:54 PM jlierly. BFF 01 7/01/16 PB BLDG FLOOR FRAMING 7/05/16 AP July 1, 2016 12:06:01 PM pbarthol. todd 565-6269 July 5, 2016 9:29:26 AM pbarthol. BEXS 01 8/18/16 JLL BLDG EXTERIOR SHEETING _ 8/18/16 AP August 18, 2016 8:10:24 AM jlierly. Todd 565-6269 August 18, 2016 4:50:01 PM jlierly. BEXS 02 8/30/16 JLL BLDG EXTERIOR SHEETING _ 8/31/16 AP August 30, 2016 8:37:05 AM jlierly. todd 565-6269 August 31, 2016 8:27:20 AM jlierly. BAIR O1 10/17/16 JLL BLDG AIR SEAL 10/17/16 AP October 17, 2016 1:58:18 PM jlierly. Todd 565-6249 October 17, 2016 3:41:02 PM jlierly. BL3 01 10/17/16 JLL BLDG FRAMING 10/17/16 AP October 17, 2016 1:58:50 PM jlierly. October 17, 2016 3:41:02 PM jlierly. BLWS 01 10/20/16 JLL BLDG INSULATION WALL/FLOOR 10/20/16 AP October 20, 2016 9:20:06 AM jlierly. Todd 565-6266 October 20, 2016.4:23:26 PM jlierly. PW99 01 11/30/16 RV PUBLIC WORKS FINAL 12/01/16 AP December 1, 2016 10:03:32 AM rvess. December 1, 2016 10:04:20 AM rvess. BL99 01 12/02/16 BLDG FINAL December 2, 2016 8:54:15 AM jlierly. Todd 775-241-8809 PERMIT: ME 00 MECHANICAL PERMIT REQUESTED - INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ ME1 01 10/17/16 JLL MECHANICAL ROUGH-IN . 10/17/16 AP October 17, 2016 2:01:05 PM jlierly. October 17, 2016 3:41:02 PM jlierly. ME99 01 12/02/16 JLL MECHANICAL FINAL ----------------------------------- CONTINUED ONTO NEXT PAGE --------------------------------- PREPARED 12/02/16, 8:50:18 INSPECTION TICKET PAGE 3 CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 12/02/16 --------------- - ADDRESS : 1315 DUTCH DR SUBDIV: CONTRACTOR DUTCH DRIVE DEVELOPMENT LLC PHONE (360) 565-6269 OWNER PA PARTNERS LLC PHONE PARCEL 06-30-01-8-0-0200-0000- APPL NUMBER: 15-00001174 RES NEW SFR -------------------------—--------------—----------------------------—---------------------- REQUESTED fNS DESCRIPTION TYP/SQ COMPLETED RESULTS/COMMENTS ------- - - - --------- -- -------- --------------------- ---- — December 2, 2016 8:54:47 AM jlierly.— PERMIT: PL 00 PLUMBING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ PL2 .01 10/17/16 JLL PLUMBING ROUGH-IN 10/17/16 AP October 17, 2016 2:01:24 PM jlierly. October 17, 2016 3:41:02 PM jlierly. - PL99 01 12/02/16PLUMBING FINAL December 2, 2016 8:54:58 AM jlierly. -------------------- -- -------- -- ------------ COMMENTS AND NOTES -------------------------------------- ►. CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT- BUILDIN VISION. 32,1 EAST 5TH STREET, PORT ANGELES, WA 98362 Application Number . . . . . 15-00001174 Date 4/27/16 Application pin number . . . 408200 Property Address . . . . . . 1315 DUTCH DR REPORT SALES TAX ASSESSOR PARCEL NUMBER: 06-30-01-8-0-0200-0000- Application type description RES NEW SFR on your state excise tax form Property Name . . . . . . to the City of Port Angeles Pro ert Use Property Zoning . . . . . . . RS9 RESDNTL SINGLE FAMILY (Location Code 0502 Application valuation . . . . 152792 ----------------------------------------------------------- Application desc 1 STY 3BED 2 BATH 1580SF SFR W/566SF GARAGE ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ PA PARTNERS LLC DUTCH DRIVE bEVELOPMENT LLC 710 LARRABEE AVE 710 LARRABEE AVE BELLINGHAM WA 98225 BELLINGHAM BELLINGHAM WA 98225 (3 60) 565-6269 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT -RESIDENTIAL Additional desc 2272SF 1 STRY SFR Permit Fee . . . . 1317.05 Plan Check Fee 856.08 Issue Date . . . . 4/27/16 Valuation . . . . 152792 Expiration Date 10/24/16 (. Qty Unit Charge Per Extension BASE FEE 1020.25 53.00 5.6000 THOU BL-100,001-500K (5.60 PER K) 296.80 y ---------------------------------------------------------------------------- �' Permit . . . . . . MECHANICAL PERMIT r Additional desc SFR MECHANICAL Permit Fee . . . . 97.20 Plan Check Fee .00 4 Issue Date . . . . 4/27/16 Valuation . . . . 0 S Expiration Date 10/24/16 * Qty Unit Charge Per Extension BASE FEE 50.00 1.00 14.8000 EA ME-FURN/HP/FAU < OR = 5 TON 14.80 '^ 3.00 7.2500 EA ME-VENT FAN (S,INGLE DUCT) 21.75 v 1 1.00 10.6500 EA ME-HOOD/DUCT-MECH. EXHAUST 10.65 ---------------------------------------------------------------------------- `vJ Permit . . . . PLUMBING PERMIT �- Additional desc SFR PLUMBING Permit Fee . . . . 149.00 Plan Check Fee .00 Issue Date . . . 4/27/16 Valuation . . . . 0 Expiration Date 10/24/16 Qty Unit Charge Per Extension BASE FEE 50.00 7.00 7.0000 EA PL-PLUMBING TRAP 49.00 1.00 7.0000 EA PL-WATER LINE 7.00 i 3.00 7.0000 EA PL-DRAIN VENT PIPING 21.00 ff` t/� Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construct' rmance of const5pictiop. Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder) T:Forms/Building Division/Building Permit t .BUILDING PERMIT INSPECTION RECORD +�. R ASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS— Buik g Inspections 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION: Footings Stemwall Foundation Drainage/Downspouts Piers Post Holes(Pole Bldgs.) PLUMBING: Under Floor/Slab Rough-In Water Line Meter to Bldg) Gas Line Back Flow/Water AIR SEAL: Walls Ceiling FRAMING: Joists/Girders/Under Floor Shear Wall/Hold Downs Walls/Roof/Ceiling Drywall Interior Braced Panel Only) T-Bar INSULATION: Slab Wall/Floor/Ceiling MECHANICAL: Heat Pump/Furnace/FAU/Ducts Rough-In Gas Line Wood Stove/Pellet/Chimney Commercial Hood/Ducts MANUFACTURED HOMES: Footing/Slab Blocking&Hold Downs Skirting PLANNING DEPT. Separate Permit#s SEPA: Parkin /Lighting ESA: a Lndscaping SHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE Inspection Type _ Date Accepted By Electrical 417-4735 Construction -R.W. PW /Engineering 417-4831 Fire 417-4653 Planning 417-4750 Building 417-4815 n�E CITY OF PORT ANGELES go; DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT- BUILDING DIVISION 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Page 2 , Application Number . . . . . 15-00001174 Date 4/27/16 Application pin number . . . 408200 REPORT SALES TAX Qty Unit Charge Per Extension on your state excise tax form 1.00 15.0000 EA PL-SEWER LINE 1 1.00 7.0000 EA PL-WATER HEATER 7.00 to the City of Port Angeles --------------------------------------------------------------- Special Notes and Comments (Location Code 0502) September 24, 2015 9:11:59 AM rbecker. If you are installing a closed fire system, you will need to install a double check valve assembly. If you are installing an open fire system, then you do noy need to install a backflow assembly. If you have any questions call Ron Becker at 360-417-4886, Fax:366-452-4972, or E-mail:rbecker@cityofpa.us Address numbers shall be plainly visible from the street. Address numbers shall be a minimum of six inches high and be of contrasting color from-.the background. Call for cover inspection for all sprinkler installations. A full acceptance test will be required for the fire sprinkler system. This project will require seperate permit and fire sprinkler plans for review. October 7, 2015 9:56:53 AM pbarthol. project will result in a single story 2272sf SFR with 20.6% lot coverage and 24.6% site coverage. Setbacks ok per the Site plan provided. Electrical load calculations and electrical permits are required. Ditches & 12" culverts will be installed to City Standards. See Public Works Engineering for Standards. r 1. Establishing Construction Access. 2. Install sediment controls BMPs. 3. Stabilize exposed soils. 4. Protect slopes from erosion. 5. Protect drain inlets. G. Control pollutants including but not limited to spills, concrete wash out, exposed aggregate processes, concrete grinding and saw cut waste water. 7. Maintain.temporary and permanent erosion control BMPS during project. All disturbed area's on site not covered by new improvements should meet the attached soil quality and depth standard. " Consider applying for the City Green Infrastructure Rebate of up to $750.00 towards the materials to install rain garden to control roof and driveway runoff. Also rebates available for downspout disconnections.Contact Jonathan Boehme at 360 417-4811 All construction work within the City right of way requires a separate Right of Way Construction application to be completed by the contractor and approved by Public Works Engineering prior to the start of work. A pedestrian or Separate Permits are required forelectrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized isnot commenced within 180 days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder) T:Forms/Building Division/Building Permit BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS— Building Inspections 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION: Footings Stemwall Foundation Drainage/Downspouts Piers Post Holes(Pole Bldgs.) PLUMBING: Under Floor/Slab Rough-in Water Line Meter to Bldg) Gas Line Back Flow/Water AIR SEAL: Walls Ceiling FRAMING: Joists/Girders/Under Floor Shear Wall/Hold Downs Walls/Roof/Ceiling Drywall Interior Braced Panel Only) T-Bar INSULATION: Slab Wall/Floor/Ceiling MECHANICAL: Heat Pum /Furnace/FAU/Ducts Rough-in Gas Line Wood Stove/Pellet/Chimney Commercial Hood/Ducts MANUFACTURED HOMES: Footing/Slab Blocking&Hold Downs Skirting PLANNING DEPT. Separate Permit#s SEPA: Parkin /Lighting ESA: Landscaping I ISHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE Inspection Type _ Date Accepted By Electrical 417-4735 Construction -R.W. PW /Engineering 417-4831 Fire 417-4653 Planning 417-4750 Building 417-4815 %' CITY OF PORT ANGELES � DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT- BUILDING DIVISION t. r� 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Page 3 Application Number . . . . . 15-00001174 Date 4/27/16 Application pin number . . . 408200 ----------------------- ---------------------------------- REPORT SALES TAX Special Notes and Comments on your state excise tax form traffic control plan is to be submitted for approval with to the Cit of Port Angeles the application as necessary. y 9 Sanitary sewer connection inspection is required by (LOCaIf/O/ii COC@ 0502) Public Works prior to back fill of ditch. 24 hour advance notice is required. Public Works Inspection request line 417-4831 Trench safety per applicable laws. Temp erosion control and surface restoration responsibility of applicant. Contact City inspector prior to start of work @ 360 417-4831. No attachment to sanitary sewer of stormwater roof leaders, foundation drains, yard drains, or any other CSO contribution is allowed. Construct driveway to City Standards. Concrete with exposed aggregate or other non-standard finishes(including colors or dyes)are not allowed in the City road right of way. Broom finish only. An inspection'by Public Works Engineering is required prior to pouring concrete. Public Works inspection - request line 417-4831 The contractor making the connection to an existing water meter is responsible to adjust water meter depth so that there is a minimum of 4 to 6 inches of clearance between the bottom of the meter box lid and the top of the meter at finish grade. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . RES UNDERGRND SERVICE FEE 770.00 MILW DRIVE ASSESSMENT 240.00 SEWER SYSTEM DELV CHARGE 2260.00 STATE SURCHARGE 4.50 PW WATER SYSTEM USE FEE 2260.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 1563.25 1563.25 .00 .00 Plan Check Total 856.08 856.08 .00 .00 Other Fee Total 5534.50 5534.50 .00 .00 Grand Total 7953.83 7953.83. .00 .00 Separate Permits are required forelectrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized isnot commenced within.180 days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions 9 9 9 Y of an state or local P y o law regulating construction or the performance of construction. Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder) T:Forms/Building Division/Building Permit BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS— Building Inspections 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION: Footings Stemwall Foundation Drainage/Downspouts Piers Post Holes(Pole Bldgs.) PLUMBING: Under Floor/Slab Rough-In Water Line Meter to Bldg) Gas Line Back Flow/Water AIR SEAL: Walls Ceiling FRAMING: Joists/Girders/Under Floor Shear Wall/Hold Downs Walls/Roof/Ceiling Drywall Interior Braced Panel Only) T-Bar INSULATION: Slab Wall/Floor/Ceiling MECHANICAL: Heat Pump/Furnace/FAU/Ducts Rough-in Gas Line Wood Stove/Pellet/Chimney Commercial Hood/Ducts MANUFACTURED HOMES: Footing/Slab Blocking&Hold Downs Skirting PLANNING DEPT. Separate Permit#s SEPA: Parkin /Lighting ESA: Landscaping SHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE Inspection Type _ Date Accepted By Electrical 417-4735 Construction - R.W. PW I Engineering 417-4831 Fire 417-4653 Planning 417-4750 Building 417-4815 CIT �RT NGELES ; For City Use CITY OF a _ _ - - Permit# W A s H INGTO N, U. S. ^tl Date Received: 321 E 51h Street f ate Approved Port Angeles,WA 9836 P:360-417-4817 F:360-417-4711 Email:permits0citvofpa.us BUILDING PERMI APPLICATION Project Address: )3!!57' --r C -> J s Phone: 3(6?O .s Primary Contact:—Tp (, Email: Name Phone 0A 3(ao Property Mailing Address Email Owner ?I o t-�4 iZRA i C- &JG City State Zip 92.ZS� Name Phone tpv-rc�A JIF- DC Lts�►Mme/ - 300 o Contractor Address Email Information -710 La`���' City EI--. )At' State �Irj� Zip 22 Contractor License# Exp.Date: Legal Description: Zoning: Tax Parcel # Project Value: (materials and labor) �T ZD -39 r VCa s3LQ._rs U3W 18G®-4-o 0 1 s 16-2— 792-- Residential Commercial ❑ Industrial ❑ Public ❑ Permit Demolition ❑ Fire ❑ Repair ❑ Reroof(tear off/lay over) ❑ Classification For the following, fill out both pages of permit application: (check New Construction/�Q Exterior Remodel ❑ Addition ❑ Tenant Improvement ❑ appropriate) Mechanical ❑ Plumbing ❑ Other ❑ Fire Sprinkler System Proposed Irrigation System Proposed or Proposed Bathrooms Proposed Bedrooms or Existing? Yes ANo 0 Existing? Yes O No 2 3 In addition to standard hard copy submittals please send a PDF copy of all Stormwater plans and Engineering to www.stormwaterocityofpa.us Project Description I�C: i LJ—� '-tc9Z- — w C-06,h P"A Is project in a Flood Zone: Yes 0 Noig Flood Zone Type: If in a Flood Zone, what is the value of the structure before proposed improvement? $ I have read and completed the application and know it to be true and correct. I am authorized to apply for this permit and understand that it is my responsibility to determine what permits are required and to obtain permits prior to work. I understand that plan review fees are not refundable after review has occurred. I understand that I will forfeit review fees if I withdraw the application before the permit is issued. I understand that if the permit is not picked up/issued within iSo days of submittal,the application will be considered abandoned and the fees will be forfeited. �� �, — ,� s,�e ,•� CC lZ Date Print Name Signature Residential Structures Existing Proposed Construction For Office Use Area DesdriprigrLgs(SQ FT) Floor area Floor area $Value new area Basement First Floor p 2j ISY�U Second Floor Covered Deck/Porch/Entry Deck(over 30"or 2 Id floor) Garage Carport Other(describe) Area Totals ,Z -� /SZ ?Z1 Commercial Structures Area Descriptions(SQ FT) Existing Proposed Construction For Office Use Floor area Floor area $Value new area Existing Structure (s) Proposed Addition Tenant Improvement? Other work(describe) Site Area Totals Lot/Site Coverage Calculations Lot Size(sq ft) Lot Coverage(sq ft)foot print of %Lot Coverage(Total lot cov=lot size) Max Bidg/Height 11 t7 L;-2— all structures 2°L'7'Z sq ft 2a r (U,% /5 Site Coverage(Sq Ft of all impervious) %of Sitee Coverage(total site cov_lot size) Mechanical Fixtures Indicate how many of each type of fixture to be installed or relocated as part of this project. Air HandlerSize: # Haz/Non-Haz Piping Outlets: Appliance Exhaust Fan # Heater(Suspended,Floor,Recessed wall) # Boiler/Compressor Size: # Heating/Cooling appliance # repair/alteration Evaporative Cooler(attached,not # Pellet Stove/Wood-burning/Gas # portable) Fireplace/Gas Stove/Gas Cook Stove/Misc. Fuel Gas Piping #of Outlets: Ventilation Fan,single duct # Furnace/Heat Pump/ Size: # Ventilation System # Forced Air Unit IIZ-V- `T U Plumbing Fixtures Indicate how many of each type of fixture to be installed or relocated Plumbing Traps # I Water Heater # Plumbing Vent piping # Medical gas piping #of Outlets: Water Line # Fuel gas piping #of Outlets: Sewer Line # j Industrial waste pretreatment interceptor Grease Trap) Size Other describe T:\BUILDING\APPLICATION FORMS\Current BP Application\Building Permit 4-17-13.docx DUTCH DRIVE WATER LINE CULVERT EXIST DRAINAGE • DITCH- 84j: ITCH- • z Q� w. w �5.. 18_011 \�� N 3:o n N ELECTRICAL SETBACK — < / — i SEWER COVERED LgRY NEW SFD CONDENSER ON CONC PAD LJLu ♦ \\ I COVERED PATIOS I I o \ -011 ,-I I ° S I�TBACK \ TIGHTLINE TIED TO \\ I I DOWNSPOUTS&FTG DRAIN-DAYLIGHT \ % I \TO DITCH I I I I I i SITE PLAN NORTH 1" = 30' JUAN de FUr%..,/-%A BLUFFS 1315 DUTCH DRIVE SITE PLAN PORT ANGELES, WA 98363 Al I 60'-8" I I I 12 WC I 1 SINK DW II SHOWE - W II MSTR BATH 11'-0"x 9'-4" i I Q P I Sv CPT GREAT ROOM ,r---- L J I 75 dm I I 15'-0"x 20'-10" KITCHEN to I vaNrrY -------------- -- CATHEDRAL CEILING 3 ;; 9'-11"x 15'-6" 5 I I _ . LINEN MASTER BEDROOM -------------------- ------ �+;-- -------- '- ® 15 8"x12 6" LLJCATHEDRAL CEILING WI C ® I T12"X 5'-0" ii PANTRY DESK L--- EM ENCY U ESCA 3I I o -------- -------- --------------�--- rii 5 113 I I �I I ® CLOSET w/R&S I F- L13 Jit 3 L❑-J - I I 3 3 rn ii vii q � I LU of HB I :o ry I i L " • �, CLOS I I w ;-4 I I-- - I- x r -1 a = r, > I F, w 'P I T� . I F<-lx I DN 0 I x I °° - i� BEDROOM 3 I BEDROOM 2 ., LU 75 I 12'-3"x 10'-10' I > �' 3 W 1 3 12'-3"X 11'-2" O N DRY 75 cfm Ln 6 Fu x T-7" I-1 I �U - - T - - - - - - STEP 8 EMERGENCY I EMERGENCY Q ESCAPE ESCAPE I I - HW HTR I I I I � I I Prescriptive Energy Code Compliance for All Climate Zones in Washington Project Information Contact Infouna6on Lot 20 Juan de Fuca Bluffs Todd Spencer 1311 Dutch Drive Upperleft Studios Port Angeles WA 98363 todd@upperleftstudios.com 360-565-6269 This project will use the requirements of the Prescriptive Path below and incorporate the the minimum values listed.In addition,based on the size of the structure,the appropriate number of additional credits are checked as chosen by the permit applicant. Authorized Representative Date All Climate Zones R-Value U-Factor'' Fenestration U-Factor° n/a 0.30 Skylight U-Factor n/a 0.50 Glazed Fenestration SHGC°" n/a n/a Ceiling 49' 0.026 Wood Frame Wall"' 21 int 0.056 Mass Wall R-Value' 21/21" 0.056 Floor 309 0.029 Below Grade Wall" 10/15/21 int+TB 0.042 Slab°R-Value&Depth 10,2 ft n/a *Table R402.1.1 and Table R402.1.3 Footnotes included on Page 2. Each dwelling unit in one and two-family dwellings and townhouses,as defined in Section 101.2 of the International Residential Code shall comply with sufficient options from Table R406.2 so as to achieve the following minimum number of credits: ❑ Small Dwelling Unit: 0.5 points Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration area. Additions to existing building that are less than 750 square feet of heated floor area. C7t.Medium Dwelling Unit: 1.5 points Idl All dwelling units that are not included in#1 or#3,including additions over 750 square feet. I.Large Dwelling Unit: 2.5 points Dwelling units exceeding 5000 square feet of conditioned floor area. Table R406.2 Summary Option Description Credit(s) 1a Efficient Building Envelope 1a 0.5 0.5 11b Efficient Building Envelope 1b 1.0 1c Efficient Building Envelope 1c 2.0 2a Air Leakage Control and Efficient Ventilation 2a 0.5 21b Air Leakage Control and Efficient Ventilation 21b 1.0 2c Air Leakage Control and Efficient Ventilation 2c 1.5 3a High Efficiency HVAC 3a 0.5 31b High Efficiency HVAC 3b 1.0 1.0 3c High Efficiency HVAC 3c 2.0 3d High Efficiency HVAC 3d 1.0 4 High Efficiency HVAC Distribution System 1.0 5a Efficient Water Heating 0.5 5b Efficient Water Heating 1.5 6 1 Renewable Electric Energy 0.5 1200wrl 0.0 Total Credits 1.50 *Please refer to Table R406.2 for complete option descriptions http://www.energy.wsu.edu/Documents/2012%2ORes%2OEnergy.pdf Table R402.1.1 Footnotes For SI: 1 foot.= 304.8 mm, ci .=continuous insulation, int.= intermediate framing. e R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity which is less than the label or design thickness of the insulation,the compressed R-value of the insulation from Appendix Table A101.4 shall not be less than the R-value specified in the table. b The fenestration U-factor column excludes skylights.The SHGC column applies to all glazed fenestration. Exception: Skylights may be excluded from glazed fenestration SHGC requirements in Climate Zones 1 through 3 where the SHGC for such skylights does not exceed 0.30. "10/15/21.+TB" means R-10 continuous insulation on the exterior of the wall, or R-15 on the continuous insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the basement wall at the interior of the basement wall. "10/15/21.+TB" shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. "10/13" means R-10 continuous insulation on the interior or exterior of the home or R-13 cavity insulation at the interior of the basement wall. "TB" means thermal break between floor slab and basement wall. d R-10 continuous insulation is required under heated slab on grade floors. See R402.2.9.1. e There are no SHGC requirements in the Marine Zone. f Basement wall insulation is not required in warm-humid locations as defined by Figure R301.1 and Table R301.1. 9 Reserved. h First value is cavity insulation, second is continuous insulation or insulated siding, so "13.+5" means R-13 cavity insulation plus R-5 continuous insulation or insulated siding. If structural sheathing covers 40 percent or less of the exterior, continuous insulation R-value shall be permitted to be reduced by no more than R-3 in the locations where structural sheathing is used to maintain a consistent total sheathing thickness. 1 The second R-value applies when more than half the insulation is on the interior of the mass wall. J For single rafter-or joist-vaulted ceilings, the insulation may be reduced to R-38. k Int. (intermediate framing) denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation. • 1 Log and solid timber walls with a minimum average thickness of 3.5 inches are exempt from this insulation requirement. Table R402.1.3 Footnote a Nonfenestration U-factors shall be obtained from measurement, calculation or an approved source or as specified in Section R402.1.3. BRACED WALL LINE CALCULATIONS BWL A BASED ON WIND(100 MPH): BWL 2 BASED ON WIND(100 MPH): BWL SPACING=25 =3.0' BWL SPACING=24' =4.80' FACTORS: FACTORS: EXPOSURE D: 1.50 EXPOSURE D: 1.50 RIDGE HEIGHT=10': 1.00 RIDGE HEIGHT=10': 1.00 WALL HEIGHT=8': 0.90 WALL HEIGHT=8': 0.90 #BWL=3: 1.30 #BWL=2: 1.00 INTERIOR GWB: 1.00 INTERIOR GWB: 1_00 TOTAL FACTOR: 1.76 TOTAL FACTOR: 1.35 TOTAL BWP=3.0"1.76 =5.28' TOTAL BWP=4.80-1.35 =6.48' BASED ON SDC(D2) BASED ON SDC(D2) BWL LENGTH=61' =12.91' BWL LENGTH=35' =7.45' FACTORS: FACTORS: STORY HEIGHT=8': 1.00 STORY HEIGHT=8': 1.00 BWL SPACING=25': 1.20 BWL SPACING=24': 1.00 WALL DEAD LOAD=<15 PSF: 1.00 WALL DEAD LOAD=<15 PSF: 1.00 ROOF/CEILING DEAD LOAD=<15 PSF(ROOF ONLY): 1.00 ROOF/CEILING DEAD LOAD=<15 PSF(ROOF ONLY): 1.00 INTERIOR GWB: 1.00 INTERIOR GWB: 1.00 TOTAL FACTOR: 1.00 TOTAL FACTOR: 1.00 TOTAL BWP=12.91'•1.20 =15.49' TOTAL BWP=7.45''1.00 =7.45' j BWL B BASED ON WIND(100 MPH): BWL 3 BASED ON WIND(100 Mn 1 BWL SPACING=25' =3.0' BWL SPACING=24' =4.80' FACTORS: FACTORS: EXPOSURE D: 1.50 EXPOSURE D: 1.50 RIDGE HEIGHT=10': 1.00 RIDGE HEIGHT=19: 1.00 WALL HEIGHT=8': 0.90 WALL HEIGHT=8': 0.90 #BWL=3: 1.30 #BWL=2: 1.00 INTERIOR GWB: 1.00 INTERIOR GWB: 1.00 TOTAL FACTOR: 1.76 TOTAL FACTOR: 1.35 TOTAL BWP=3.0-1.76 =5.28' TOTAL BWP=4.80-1.35 =6.48' BASED ON SDC(D2) BASED ON SDC(D2) BWL LENGTH=48' =10.18' BWL LENGTH=35' =7.45 FACTORS: FACTORS: STORY HEIGHT=8': 1.00 STORY HEIGHT=8': 1.00 BWL SPACING=25: 1.20 BWL SPACING=24': 1.00 • WALL DEAD LOAD=<15 PSF: 1.00 WALL DEAD LOAD=<15 PSF: 1.00 ROOF/CEILING DEAD LOAD=<15 PSF(ROOF ONLY): 1.00 ROOF/CEILING DEAD LOAD=<15 PSF(ROOF ONLY): 1.00 INTERIOR GWB: 1_00 INTERIOR GWB: 1.00 TOTAL FACTOR: 1.00 TOTAL FACTOR: 1.00 TOTAL BWP=10.18"1.20 =12.22' TOTAL BWP=7.45"1.00 =7.45' BWL C BASED ON WIND(100 MPH): BWL 4 BASED ON WIND(100 MPH): BWL SPACING=25 =3.0' BWL SPACING=35' =6.75' FACTORS: FACTORS: EXPOSURE D: 1.50 EXPOSURE D: 1.50 RIDGE HEIGHT=10': 1.00 RIDGE HEIGHT=10': 1.00 WALL HEIGHT=8': 0.90 WALL HEIGHT=8': 0.90 #BWL=3: 1.30 #BWL=3: 1.30 INTERIOR GWB: 1.00 INTERIOR GWB: 1.00 TOTAL FACTOR: 1.76 TOTAL FACTOR: 1.76 TOTAL BWP=3.0"1.76 =5.26' TOTAL BWP=6.75"1.76 =11.88 BASED ON SDC(D2) BASED ON SDC(D2) BWL LENGTH=30' =6.40' BWL LENGTH=24' =5.14' FACTORS: FACTORS: STORY HEIGHT=8': 1.00 STORY HEIGHT=8': 1.00 BWL SPACING=35': 1.40 BWL SPACING=25': 1.20 WALL DEAD LOAD=<15 PSF: 1.00 WALL DEAD LOAD=<15 PSF: 1.00 ROOF/CEILING DEAD LOAD=<15 PSF(ROOF ONLY): 1.00 ROOF/CEILING DEAD LOAD=<15 PSF(ROOF ONLY): 1.00 INTERIOR GWB: 1_00 INTERIOR GWB: 1.00 TOTAL FACTOR: 1.40 TOTAL FACTOR: 1.00 TOTAL BWP=6.40' 1.40 =8.96' TOTAL BWP=5.14'•1.20 =6.17' BWL'I BASED ON WIND(100 MPH): BWL 5 BASED ON WIND(100 Mn BWL SPACING=4' =2.50' BWL SPACING=18' =3.70' FACTORS: FACTORS: EXPOSURE D: 1.50 EXPOSURE D: 1.50 RIDGE HEIGHT=10': 1.00 RIDGE HEIGHT=10': 1.00 WALL HEIGHT=8': 0.90 WALL HEIGHT=8': 0.90 #BWL=5: 1.60 #BWL=3: 1.30 INTERIOR GWB: 1_00 INTERIOR GWB: 1_00 TOTAL FACTOR: 2.16 TOTAL FACTOR: 1.76 TOTAL BWP=2.50-2.16 =5.40' TOTAL BWP=3.70-1.76 =6.51 BASED ON SDC(D2) BASED ON SDC(D2) BWL LENGTH=19' =4.08' BWL LENGTH=30' =6.40' FACTORS: FACTORS: STORY HEIGHT=8': 1.00 STORY HEIGHT=8': 1.00 BWL SPACING=4': 1.00 BWL SPACING=18': 1.00 WALL DEAD LOAD=<15 PSF: 1.00 WALL DEAD LOAD=<15 PSF: 1.00 ROOF/CEILING DEAD LOAD=<15 PSF(ROOF ONLY): 1.00 ROOF/CEILING DEAD LOAD=<15 PSF(ROOF ONLY): 1.00 INTERIOR GWB: 1.00 INTERIOR GWB: 1.00 TOTAL FACTOR: 1.00 TOTAL FACTOR: 1.00 TOTAL BWP=4.08-1.00 =4.08 TOTAL BWP=6.40"1.00 =6.40' Prescriptive Energy Code Compliance for All Climate Zones in Washington Project Information Contact Information Todd Spencer T!A-d-Ala---- Upperleft Studios ios.com 360-565-6269 This project will use the requirements of the Prescriptive Path below and Incorporate the the minimum values listed.In addition,based on the size of the structure,the appropriate number of additional credits are checked as chosen by the permit applicant. Authorized Representative Date All Climate Zones R-Valuea U-Factor' Fenestration U-Factor° n/a 0.30 Skylight U-Factor n/a 0.50 Glazed Fenestration SHGC" n/a n/a Ceiling 49' 0.026 Wood Frame Wall,."' 21 int 0.056 Mass Wall R-Value' 21/21" 0.056 Floor 309 0.029 Below Grade Wall" 10/15/21 int+TB 0.042 Slab'R-Value&Depth 10,2 It n/a 'Table R402.1.1 and Table R402.1.3 Footnotes included on Page 2. Each dwelling unit in one and two-family dwellings and townhouses,as defined In Section 101.2 of the International Residential Code shall comply with sufficient options from Table R406.2 so as to achieve the following minimum number of credits: F-1.Small Dwelling Unit: 0.5 points Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration area. Additions to existing building that are less than 750 square feet of heated floor area. I77t.Medium Dwelling Unit: 1.5 points ISI All dwelling units that are not included in#1 or#3,including additions over 750 square feet. �.Large Dwelling Unit: 2.5 points Dwelling units exceeding 5000 square feet of conditioned floor area. Table R406.2 Summary Option Description Credit(s) 1a Efficient Building Envelope 1a 0.5 0.5 1b Efficient Building Envelope 1b 1.0 1c Efficient Building Envelope 1c 2.0 2a Air Leakage Control and Efficient Ventilation 2a 0.5 2b Air Leakage Control and Efficient Ventilation 21b 1.0 2c Air Leakage Control and Efficient Ventilation 2c 1.5 3a i High Efficiency HVAC 3a 0.5 3b High Efficiency HVAC 3b 1.0 1.0 3c High Efficiency HVAC 3c 2.0 3d High Efficiency HVAC 3d 1.0 4 High Efficiency HVAC Distribution System 1.0 5a Efficient Water Heating 0.5 5b Efficient Water Heating 1.5 61 Renewable Electric Energy 0.5 '1200 Rwri 0.0 Total Credits 1.50 *Please refer to Table R406.2 for complete option descriptions http://www.energy.wsu.edu/Documents/2012%2ORes%2OEnergy.Pdf I Table R402.1.1 Footnotes For SI: 1 foot.= 304.8 mm, ci .=continuous insulation, int.= intermediate framing. a R-values are minimums. U-factors and SHGC are maximums.When insulation is installed in a cavity which is less than the label or design thickness of the insulation,the compressed R-value of the insulation from Appendix Table All 01.4 shall not be less than the R-value specified in the table. b The fenestration U-factor column excludes skylights.The SHGC column applies to all glazed fenestration. Exception: Skylights may be excluded from glazed fenestration SHGC requirements in Climate Zones 1 through 3 where the SHGC for such skylights does not exceed 0.30. "10/15/21.+TB" means R-10 continuous insulation on the exterior of the wall, or R-15 on the continuous insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the basement wall at the interior of the basement wall. "10/15/21.+TB"shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. "10/13" means R-10 continuous insulation on the interior or exterior of the home or R-13 cavity insulation at the interior of the basement wall. "TB" means thermal break between floor slab and basement wall. d R-10 continuous insulation is required under heated slab on grade floors. See R402.2.9.1. e There are no SHGC requirements in the Marine Zone. f Basement wall insulation is not required in warm-humid locations as defined by Figure R301.1 and Table R301.1. 9 Reserved. h First value is cavity insulation, second is continuous insulation or insulated siding,so"13.+5" means R-13 cavity insulation plus R-5 continuous insulation or insulated siding. If structural sheathing covers 40 percent or less of the exterior,continuous insulation R-value shall be permitted to be reduced by no more than R-3 in the locations where structural sheathing is used to maintain a consistent total sheathing thickness. 1 The second R-value applies when more than half the insulation is on the interior of the mass wall. J For single rafter-or joist-vaulted ceilings,the insulation may be reduced to R-38. k Int. (intermediate framing) denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation. • Log and solid timber walls with a minimum average thickness of 3.5 inches are exempt from this insulation requirement. Table R402.1.3 Footnote a Nonfenestration U-factors shall be obtained from measurement,calculation or an approved source or as specified in Section R402.1.3.