HomeMy WebLinkAbout139 W 2nd Street Address: 139 W 2nd Street PREPARED 6/27/17, 11:56:14 INSPECTION TICKET .PAGE 5 CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 6/27/17 ------ -----------—-----------—--' - ADDRESS . : 139 W 2ND ST SUBDIV: CONTRACTOR D BAIN CONSTRUCTION PHONE (360) 460-6325 OWNER JON & IANTHA FRAZER PHONE (360) 460-1071 PARCEL 06-30-00-0-0-3235-0000- APPL NUMBER: 17-00000284 RES REPAIR ---- ----------- ---------------------------- PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ BLFW O1 5/08/17 JLL BLDG FOUND FTG/STEM WALL _ 5/15/17 AP May 8, 2017 9:10:42 AM jlierly. DEck on slope side of home.jll May 8, 2017 9:11:14 AM jlierly. darren 460-6325 May 15, 2017 4:48:30 PM jlierly. BL3 01 5/19/17 JLL BLDG FRAMING 5/19/17 AP May 19, 2017 10:03:37 AM jlierly. Darren 460-6325 May 19, 2017 4:12:06 PM jlierly. BL99 016/27:17 JL BLDG FINAL TIME: 17:00 s, ------- -- ------------- COMMENTS AND NOTES ..�► �_l. + yr rVK1 ANUtL1;J ���i. DEPARTMENT OF COMMUNITY& ECONOMIC DEVELOPMENT- BUILDING DIVISION Nr �O 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Application Number . . . . . 17-00000284 Date 4/07/17 Application pin number . . . 501672 REPORT SALES TAX Property Address . . . . . 139 W 2ND ST ASSESSOR PARCEL NUMBER: 06-30-00-0-0-3235-0000- on your state excise tax form Application type description RES REPAIR to the City of Port Angeles Subdivision Name . . . . . . Property Use . . . . . . . . (Location Code 0502) Property Zoning . . . . . . . Application valuation . . . . 15000 ---------------------------------------------------------------------------- Application desc replace upper deck ------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ JON & IANTHA FRAZER D BAIN CONSTRUCTION 139 W 2ND ST 3905.SOUTH BEAN RD PORT ANGELES WA 98362 PORT ANGELES WA 98363 (360) 460-1071 (360) 460-6325 ---------------------------------------------------------------------------- Permit . . . . BUILDING PERMIT -RESIDENTIAL Additional desc . . REPLACE UPPER DECK �1 Permit Fee . . . . 277.75 Plan Check Fee 180.54 Issue Date . . . . 4/07/17 Valuation . . . . 15000 Expiration Date 10/04/17 Qty Unit Charge Per Extension BASE FEE 95.75 13.00 14.0000 THOU BL-2001-25K (14 PER K) 182.00 ---------------------------------------------------------------------------- Special Notes and Comments April 7, 2017 3:19:57 PM pbarthol. The project will result in the replacement of and addition to an existing second floor deck. The posts for the new deck �. will be placed on existing concrete wall/footing per engineered plans without placement of any new footings in t the soil. The work shall be completed without damage to existing vegetation on the bank. If the work plan requires 4 disturbance of the bank, additional information will need to be submitted to the Planning Department for review. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE SURCHARGE 4.50 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 277.75 277.75 .00 .00 Plan Check Total 180.54 180.54 .00 .00 Other Fee Total 4.50 4.50 .00 .00 Grand Total 462.79 462.79 .00 .00 1`\ Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced,or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder) T:Forms/Building Division/Building Permit BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS Building Inspections 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION: Footings Stemwal I Foundation Drainage/Downspouts Piers Post Holes(Pole Bldgs.) PLUMBING: Under Floor/Slab Rough-in Water Line Meter to Bldg) Gas Line Back Flow/Water AIR SEAL: Walls Ceiling FRAMING: Joists/Girders/Under Floor Shear Wall/Hold Downs Walls/Roof/Ceiling Drywall Interior Braced Panel Only) T-Bar INSULATION: Slab Wall/Floor/Ceiling MECHANICAL: Heat Pump/Furnace/FAU/Ducts Rough-In Gas Line Wood Stove/Pellet/Chimney Commercial Hood/Ducts MANUFACTURED HOMES: Footing/Slab Blocking&Hold Downs Skirting PLANNING DEPT. Separate Permit#s SEPA: Parkin /Lighting ESA: Landscaping SHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE Inspection Type Date Accepted By Electrical 417-4735 Construction - R.W. PW /Engineering 417-4831 Fire 417-4653 —Planning 417-4750 Building 417-4815 ror meaty use C:9TX Of4wm 15jrkAnvik r Permit# f .. CTO Date Received: =l 321E 51h Street 1 V Date Approved Port Angeles,WA 9836 P:360-417-4817 F:360-417-4711 Email:Vermits0ciWfpa.us BUILDING PEIT,VII PPI.,ICATI®N Project Address: /3 9 V eek 7'l lrlee FOK-TAOM6 SreS6 �O�! -�Z�� Phone: L3�D 4&O – /© -71 Primary Contact: Email: / .-7 Name 011 Ph oneO �(O —/C� J r Property Mailing Address / Email Owner O CityState Zi a. �K CLps � -!)53& State - 74 p Name rl tJ 10�j Phone U 4IPIJ lD 5 f•-J Contractor Address � Email jn a i ,(�j o-r(u (6�M, -R� eo� Information City -o1LTC State Zip c���((3 Contractor License* I-p.Date: Q vo, Legal Description: Zo g:,o Tax Parcel# Project Value: (materials and labor) LOT I i 6 �A 'R 1©©0� 559 $ /5 i e vv Residential Commercial ❑ Industrial 0 Public ❑ Permit Demolition ❑ Fire ❑ Repair ❑ Reroof(tear off/lay over) ❑ Classification For the following fill out both pages of permit application: (check New Construction ❑ Exterior Remodel ❑ Addition ❑ Tenant Improvement ❑ appropriate) Mechanical ❑ Plumbing ❑ Other q ?c �l' � GI Com° l t)fmn - CJE'G� . Fire Sprinkler System Proposed Irrigation System Proposed or Proposed'Bathrooms Proposed Bedrooms 'or Existing? Yes ❑ No Existing? Yes 13No — — ( — 1^1e 'e u In addition to standard hard copy submittals please send a PDF copy of all Stormwater plans and Engineering to www.stormwater ci o a.us Project Description D11 -MC n0f1h SCA, 4� hoax Tf .c e- as .&oU 04 5 Thi ig Im1 .D reM011�. 1-4U261 e-e- 1-h� IV a W/lI Is project in a Flood Zone: Yes ® Nop Flood Zone Type: If in a Flood Zone, what is the value of the structure before proposed improvement? $ I have read and completed the application and know it to be,true and correct.I am authorized to apply for this permit and understand that it is my responsibility to determine what permits are required and to obtain permits prior to work. I understand that plan review fees are not refundable after review has occurred. I understand that I will forfeit review fees if I withdraw the application before the permit is issued. I understand that if the permit is not picked up/issued within i8o days of submittal,the application will be considered abandoned and the fees will be forfeited. Date Print ame Signature Reside ntiaLStructures_ Existing d .Proposed ; Consstt cction For Office Use Area Descriptions(SQ FT)- Floor area Floor area $Value new area Basement ( First Floor C { Second Floor Covered Deck/Porch/Entry FT-2 Deck(over 30"or 2n floor) l2-1b Garage Carport Other(describe) 1 v�J L, 1/36/36 Area Totals I cf 2 J Commercial Structures Area Descriptions(SQ FT) Existing Proposed Construction For Office Use Floor area Floor area $Value new area Existing Structure(s) Proposed Addition Tenant Improvement? _ r Other work(describe) Site Area Totals Lot/Site Coverage Calculations Lot Size(sq ft) Lot Coverage(sq ft)foot print of %Lot Coverage(Total lot cov_lot size) Max Bldg Height `7 pOQ ej - allstructures Nft 000 Z1. !v Site Covera e(9q Ft of all impervious) %of Site Coverage total site coy-lot size) a � a echanicaI"Fixtures Indicate how many of each type of re to be installed or relocated as part of this project. Air Handler Size: # Haz/Non-Haz Piping Outlets: Appliance Exhaust Fan # Heater(Suspended,Floor;,Recessed wall) # Boiler/Compressor Size: # Heating/Cooling'appliance # repair/alteration Evaporative Cooler(attached,not # Pellet Stove/Wood-burning/Gas # portable) Fireplace/Gas Stove/Gas Cook Stove/Misc. Fuel Gas Piping #of Outlets: Ventilation Fan,single duct # Furnace/Heat Pump/ Size: # Ventilation System # Forced Air Unit Plumbing Fixtures Indicate how many of each type of fixture to be installed or relocated Plumbing Traps # Water Heater # Plumbing Vent piping # Medical gas piping #of Outlets: Water Line # Fuel gas piping #of Outlets: Sewer Line # Industrial waste pretreatment interceptor Grease Trap) Size Other describe): T:\Forms\2015 CED Form Updates\Building&Permitting\BP\Building Permit 20150415.docx 20 1' 1� �.� ' `f► ` 242? � •1s rip 3ir. 'e 94 •�� �. '��.,�, � •.c e� i' 9q ti r 6 a' oma 1� id k QQ j Oct rz Q :c•p �'' E Y c pq .. Q � C�«:W G•p �" � ._ � � Tim-, �vq•�""'�'_. ,.,, i CIS 10 .. o }}, iti'� - "'�-•'_ �4.n 'fit^.:f I Y /�r.. -t.. '� .;;. " ,` ��f,�`, ,�---'_''r'^.-�, �''"�..3.�y` ~`k ,�-�u'��"��`.c,....„A-ra�.r,°`.r�".ar� d•--��--.,moi,-.. ,T li `f 4��,'s�`��Lr f� 4 M1�'�, l�,...±e ,.:... ate•... p Yr n _fr 1 ✓M i. f° , � � �. � �r ��� .��...,,.i r�r � 6 �'`I, lid p� f,�4 , i ur �;:. ';,m f �. 'uusi."'""•'. - � �'sa-s—•s��sr msz���ea u� � _. � - �1� �Q f'e� C� _iR . ., pJ l ! F' e vl� o r fly -f)i cls. c� � h o c'15� - �h i� /'e P1 04 (�-Xl6� -Thea-1 PLO She / --7 / //”"/L xrD� 34' _ ;r Balcony Deck ? Dlning Ching IV Room Upper Floor Unfinished ti m Bedroom N R Garage k 8, v 34.5' 1 34- ;r Balcony Deck A Bedroom Recreation Area Basement 3 Unfinished Area P � 34.5' Fool 'Pp-,k"-r p ! N-14` �•.............N... r.wrw • w• n• rwrr .. rw rr •a• J r � xxx 4j� ti �s . 00` f . L4 4! � Zrn(;yv 10""s lob �r77-4- �t t y. ah I-IN o� 1 ado 7000 4 r.` Picked tuiii -.".4 NORTHWESTERN TERRITORIES, INC. Engmee/s O Land Sualeyo/s O PlannefS Cons(/uC(rOn CUO/drnafr()n Y A9alenal, les!m„ NTT -W- .-WO 1 L STAB 1 L I ,r-e LVA l-UAT I ON 139 West Second Street Port Angeles , Washington Prepared for MRS . IRENE DEALEY Prepared by NORTHWES`1'ERN TERRITORIES , INC . July, 1991 717 SOUTH PEABODY. PORT ANGELES,WA 98362 (206) 4528491 1 800 654 554", FAX d52 84911 STABIL T 'I'Y F.VA IL UA I' I ON SCOPE: The evaluation requested by [1rs . Irene Dealey was reconnaissance in nature an consisted of visual observation of conditions of the house exterior and property including the slope extending northerly down from the house . Observations were made by Mr . Blase Cylwik on July 8 , 1991 and included a traverse of the slope and assessment of surficial geologic conditions . No subsurface exploration or precise measurements were performed . PRO P ER TY DESCRIPTION The house is situated at the top of a bluff or steep slope that trends about east-west through the area . Other residential structures exist adjacent on the east . The Oak Street "zig-zag" walkway traverses up the slope immediately northwest of the house . Mrs . Dealey reported that the house was constructed in 1953 . The concrete retaining wall that is aligned north-south along the east side of the property was apparently constructed prior to 1953 . The slope north of the house is undeveloped and is covered by dense brush. It slopes northward at about 35 ' . The slope is about 100 feet in height . Its base lies along the rear of a paved parking lot . A concrete wall ranging from about six to eight feet in height is present along the base of the slope . The house is served by the city sewer system . Roof runoff is conducted via eave drains and down spouts away from the house to the slope on the north . REG I ONA L GEOLOGY The subject property, surrounding areas and bluff are underlain by alluvial sediments originally deposited by outwash from receding glaciers that existed at higher elevations to the south about 15 , 000 years ago . These sediments consist predominantly of horizontally bedded , silty fine sand with lesser amounts of interlayered silt and gravel . Originally, the bluff was probably formed by marine erosion along an ancient shoreline, resulting in over-steepening and subsequent downward movement of slope materials in response to gravity. The bluff here is no longer subject to marine erosion and, in general , has nearly reached an angle of repose ? - , for the sediments composing it . Other factors , however , can affect bluff stability including excessive groundwater and the construction and grading activities of man . Nearby slope failures have recently occurred several properties to the west and two properties to the east of the subject property . 'They were likely associated with factors such as those cited above . LOCA L CONDITIONS The bluff on the north portion of the subject property as well as adjacent properties appears to be stable . No inclinations of downslope movement or impending instability of ground surfaces or man-made structures is evident . The concrete retaining wall on the east , a good indicator of ground stability, shows no significant signs of distress such as obvious tilting or cracking . One small crack noted at the top of the wall at a steel fence post opposite the northwest corner of the subject house may be primarily related to rust expansion of the post . On the west , the Oak Street " zig-zag" walkway appears to have remained stable since construction . The concrete foundation walls of the subject house that are visible above ground, as well as concrete walk-ways around the house, appear to be free of any cracking that would indicate distress or settlement . A foundation pile at the northwest corner of the house has apparently settled downward a few inches from the concrete footing since the house was constructed . No new separation is evident since placement of concrete in the separation reportedly a few years ago . No lateral movement that might suggest slope or ground instability is evident . No cracks or distress was noted in the concrete footing wall in this area . No evidence of excessive groundwater such as seeps or especially wet ground surfaces were noted around the subject house or slope on the north . No significant erosion or gullying of the slope was observed . CONCLUSIONS The property and home thereon appear to be stable and free of significant foundation problems . Most existing conditions are favorable t=o continued stability of the property. Any future development on the property involving grading , new structures, or significant foundation loads should be reviewed and approved by a foundation engineer . 1 At R E C OMM E N DA T I ON S 1 . Disposition of roof runoff drains should be investigated and confirmed to be free of leakage . In addition, the outlet of such drains should be located . All roof drainage should be conducted to the base of the bluff via pipe , ( i . e . , " tightline" ) . 2 . The apparent past settlement of the pile footing at the northwest corner of the house should be periodically monitored . If additional settlement occurs , any separation should immediately be filled with concrete . 3 . The moderate brush cover on the bluff should be satisfactory for surface stability . Heavy tree growth should be avoided . S TA NDA RD D I S C L O S U R E S T A T EM E N`I' This report is based on a visual inspection of the existing site conditions and/or facility . No scientific measurements, tests, or calculations were performed . The findings and report are limited to the normal standard of care of the industry for an investigation without benefit of scientific data and calculations . Unless construction plans are reviewed and the construction work is inspected by the Engineer, no warranty is made by the Engineer concerning conformity of the construction to the conclusions and recommendations of this report . Blase Cylwik Engineering Geologist j . R . Jerry Newlin , PE i Principal Engineer J J 7 fc: Dealey. Jul Dir : Engineer/Rpt Deck Remodel Owners: lantha and Jon Frazer 139 West 2nd Street Port Angeles, WA 98362 Structural Calculations Prepared by: Amber Brinkman, PE 9 AW N B� �w4 O WASkl �w , 7 4 � zx ,off ,p 46705 9 O `CCIS IES S'jONAL��G GENERAL WOOD LEGEND 1. DESIGN AND CONSTRUCTION OF THIS 1. ALL SAWN LUMBER SHALL CONFORM TO JON & DECK SHALL BE IN ACCORDANCE WITH 2015 THE WESTERN WOOD PRODUCTS ELEVATION IANTHA INTERNATIONAL BUILDING CODE ASSOCIATION OR THE WEST COAST LUMBER - 2. DIMENSIONS PROVIDED IN DRAWINGS INSPECTION BUREAU GRADING RULES AND TOP OF BEAM ELEVATION [x'-x"] F RAZ E R ARE APPROXIMATE AND SHOULD BE BE KILN DRIED CONFIRMED BY THE CONTRACTOR BEFORE 2. ALL SAWN LUMBER MEMBERS SHALL FOOTING STEP DECK INSTALLATION BE No. 2 OR BETTER AND HAVE THE 3. STRUCTURAL FRAMING SHALL BE SIZED FOLLOWING PROPERTIES AT A MINIMUM: O.C. ON CENTER TO SUPPORT 40 PSF LIVE LOAD IN ADDITION A. BENDING FB = 850 PSI REMODEL TO DEAD WEIGHT OF STRUCTURE: B. SHEAR FV = 150 PSI GL GLULAM 4. DEFLECTION CRITERIA- BEAM MEMBERS C. COMPRESSION PARALLEL TO GRAIN FC SHALL NOT DEFLECT MORE THAN: = 1300 PSI CONN. CONNECTION A. LIVE LOAD: SPAN/360 D. COMPRESSION PERPENDICULAR TO �Aw-N B. DEAD AND LIVE LOAD- SPAN/240 GRAIN FCP = 405 PSI EXTG. EXISTING qw� O0 v�Asr�, E. ELASTIC MODULUS E = 1,300,000 PSI CONCRETE REINFORCING z C G STEEL 3. ALL GLULAMINATED MEMBERS SHALL 1. REINFORCING STEEL SHALL CONFORM HAVE THE FOLLOWING PROPERTIES: ` TO ASTM A706, GRADE 60 A. BENDING FB(+) = 2400 PSI en 46705 o 2. DETAIL, FABRICATE, AND PLACE B. BENDING FB(-) = 1450 PSI o,��s GrsrEt�.Gn� S��NAL Er REINFORCING ACCORDING TO ACI 318, C. SHEAR FVX = 265 PSI DETAILS AND DETAILING OF CONCRETE D. COMPRESSION PARALLEL TO GRAIN FC REINFORCEMENT = 1600 PSI 3. MINIMUM COVER FROM CONCRETE E. COMPRESSION PERPENDICULAR TO. SURFACES TO REINFORCING =, 3" GRAIN FCP = 650 PSI - Z F. ELASTIC MODULUS E = 1 ,800,000 PSI w CONCRETE 4. ALL LUMBER IN CONTACT WITH THE VI 1. MINIMUM SPECIFIED COMPRESSIVE GROUND OR CONCRETE SHALL BE PRESSURE w STRENGTH OF CONCRETE, F'C, SHALL BE NOT . TREATED LESS THAN 3,000 PSI AT 28 DAYS 5. HOLES FOR BOLTS SHALL BE DRILLED 2. CONCRETE SLUMP SHALL NOT EXCEED TO THE SAME SIZE OF THE BOLT DIAMETER U) 6 INCHES WITH A 1/16" OVERSIZE CONCRETE SHALL BE CONSOLIDATED �— BY SUITABLE MEANS DURING PLACEMENTO L ) AND SHALL BE WORKED AROUND EMBEDDED ITEMS AND REINFORCEMENT AND INTO z Q CORNERS OF FORMS r z Q W w I 0 W Q m = U w U) U) LL A B C JON & 161- 3 16' IANTHA - .2 x 10 FLOOR FRAZER 2' 3 5 _ JOIST TO MATCH tj DECK 3' 14 -0' i� EXISTING 2 REMODEL 2 EXISTING FLOOR 3' � JOIST @ 16" 0.C. 1 �pwN Bh,I - E STING HOUSE �w w&WAS c� FOUNDATION/WALL { 7� z �GI6705 ��9 � 2 DECK LEVEL OSSIONAL EAG (:A B C 16' 16' 7' U) 1 ' 1 6' W it it 3' 6x �6 _ o 2 EXISTING HOUSE L 3' FOUNDATION d- N Q W � W J W Q m 1 FOUNDATION LEVEL = U W C� C� LL JON & EXISTING JOIST 2x BLOCKING DECKING PER PLAN BETWEEN JOISTS DECKING JOIST PER PLAN IANTHA CONFIRM CONN. TYPICAL TOENAILED TO BEAM FRAZER BETWEEN EXTG. JOIST AND WALL o SIMPSON H1 TIE EACH JOIST DECK CAN SUPPORT 200LB UPLIFT BEAM PER PLAN REMODEL Aro 0 - EXISTING WALL $„ 0 PER PLAN (4) #12 SCREWS POST PER PLAN qp, & ISI @ 3 o.c. STAGGERED SIMPSON CC66 w4 g WAS EACH SIDE OF JOIST HANDRAIL PER POST CAPS �w l�'c NEW JOIST PER PLAN INSTALLER H� o z BEAM PER PLANT. A 46705 . SSjONAL��G 3 2 6x6 PRESSURE TREATED POST SIMPSON � CONCRETE CB666 J � PLINTH _ p #3 TIE TOP Q N — & BOTTOM EXISTING Ld FOOTING #4 REBAR EPDXY GROUTED INTO co EXISTING FOOTING Q EMBED 5 1/2" W 1'-2" W J 00 W ' Q = U w U) Cn Li- Address: 139 W 2nd Street PREPARED 9/23/14, 10:23:11 INSPECTION TICKET PAGE 3 CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY . DATE 9/23/14 ------------------- - ADDRESS . : 139 W 2ND ST SUBDIV: CONTRACTOR DAVE'S HTG & COOLING SRVC INC PHONE (360) 452-0939 OWNER JON & IANTHA FRAZER PHONE (360) 460-1071 PARCEL 06-30-00-0-0-3235-0000- APPL NUMBER: 14-00000967 RES MECHANICAL PERMIT ------------------------------------------------------------------------------------------------ PERMIT: ME 00 MECHANICAL PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ---------------- ----------------------------------------—-—--------------- ME99 01 9/23/14 nJLL MECHANICAL FINAL September 23, 2014 9:14:15 AM pbarthol. Jon 460-1071 Call to arrange time to meet you -------------------------------------- COMMENTS AND NOTES CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY&ECONOMIC DEVELOPMENT- BUILDING DIVISION e` - 321 EAST 5TH STREET, PORT ANGELES,WA 98362 Application Number . . . . . 14-00000967 Date 8/14/14 Application pin number . . . 148078 Property Address . . . . . . 139 W 2ND ST ASSESSOR PARCEL NUMBER: 06-30-00-0-0-3235-0000- REPORT SALES TAX Application type description RES MECHANICAL PERMIT Subdivision Name . . . . . . on your state excise tax form Property Use . . . . . . . . to the City of Port Angeles Property Zoning . Application valuation . . . . 3100 (Location Code 0$02) ---------------------------------------------------------------------------- Application desc ELECTRIC FURNACE ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ JON & IANTHA FRAZER DAVE'S HTG & COOLING SRVC INC 139 W 2ND ST PO BOX 413 PORT ANGELES WA 98362 PORT ANGELES WA 98362 w (360) 460-1071 (360) 452-0939 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL PERMIT Additional desc . . ELECTRIC FURNACE Permit Fee . . . . 64.80 Plan Check Fee .00 / Issue Date . . . . 8/14/14. Valuation . . . . 0 Expiration Date 2/10/15 Qty Unit Charge Per Extension BASE FEE 50.00 1.00 14.8000 EA ME-FURN/HP/FAU < OR = 5 TON 14.80 --------------------------------------------------------------- Special Notes and Comments Per Washington State Code 51-51-315, installation of Carbon Monoxide detector(s) is required if you are installing or replacing a fuel burning appliance (wood, pellet, gas)and must be in place prior to the final. inspection of this permit. They are required to be place directly outside of each sleeping area and at least one on each floor of the house. ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 64.80 64.80 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 64.80 64.80 .00 .00 Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced,or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authorit to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. � G Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder) T:Forms/Building Division/Building Permit BUILDING PERMIT INSPECTION RECORD — PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS— Building Inspections 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION: Footings Stemwall Foundation Drainage/Downspouts Piers Post Holes(Pole Bldgs.) PLUMBING: Under Floor/Slab Rough-in Water Line Meter to Bldg) Gas Line Back Flow/Water FINAL Date Accepted b AIR SEAL: Walls Ceiling FRAMING: Joists/Girders/Under Floor Shear Wall/Hold Downs Walls/Roof/Ceiling Drywall Interior Braced Panel Only) T-Bar INSULATION: Slab Wall/Floor/Ceiling MECHANICAL: Heat Pum /Furnace/FAU/Ducts Rough-in Gas Line Wood Stove/Pellet/Chimney Commercial Hood/Ducts FINAL Date Accepted b MANUFACTURED HOMES: Footing/Slab Blocking&Hold Downs Skirting PLANNING DEPT. Separate Permit#s SEPA: Parking/Lighting ESA: Landscaping SHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE Inspection Type Date Accepted By Electrical 417-4735 Construction- R.W. PW I Engineering 417-4831 Fire 417-4653 Planning 417-4750 Building 417-4815 T:Forms/Building Division/Building Permit 08/13/2014 1 :02PM FAX 160001/0001 THE RAT NGELES CITY of ,- For City Use Permit# Date Received: 321. East S°i Street Port Angeles, WA 98362 DateApproved P: 360-417.4817 F: 360-417-4711 pernAts@Pcityofpa.us Building Permit Application ----- i... 5 --- .- ___..�... . Project Address: Main Contact: Phone # - E-Mail: Property Name fro. Q Vipho��a°F- ( 1 Owner Ma111ngAddress _ E111r11 EKY oY � Stats Zip Contractor Nwila Phone we�- Mail1ngAddcity y C ! Email 88 K Stats 47 n ZIP,,, Contractor License# u G� � ` K Expiration: Project Value: m Zoning: 'fax Parcel# �� _ -6Lot# � OCr 'rype oV Residential . commercial ® Industrial B Public ® Permit Demolition ❑ Fire ❑ Repair ® Reroof(tear off/lay over) For the following,fill out both pages of permit application: New Construction ❑ Remodel ❑ Addition ❑ Tenant Improvement ❑ Mechanical ❑ Plumbing ❑ Other 13 F.idsting Fire Sprinkler.System? Maximum height of structure Proposed BedroomsProposed Bathrooms Yes C) No I] Project .. Description I have read and completed the application and know it to be true and correct.I am authorized to apply for this permit. I understand that it is my responsibility to determine what permits are required and to obtain permits prior to working on projects. I understand that the plan review fee is not refundable after plan review has occurred. I understand that I will forfeit the review fee if 1 cancel or withdraw the application before the permit is issued. 1 understand that if the permit is not issued within 180 days of receipt,the application will be considered abandoned and the fees forfeit. Dat Print Name ^� Signature ,�