Loading...
HomeMy WebLinkAbout1402 Pendley Court Address: 11402 Pendley Court PREPARED 12/19/14, 9:16:17 INSPECTION TICKET PAGE 6 CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 12/19/14 ------------------------------------------------------------------------------------------------ ADDRESS . : 1402 PENDLEY CT SUBDIV: CONTRACTOR : PHONE OWNER PAULA HOWELL PHONE PARCEL 06-30-01-8-6-0010-0000- APPL NUMBER: 13-00001025 RES NEW SFR ------------------------------------------------------------------------------------------------ REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS -------------------------- ------------------------------------------------- ME99 01 12/19/14 JL MECHANICAL FINAL December 19, 2014 9:18:18 AM pbarthol. Bruce 912-0079 PERMIT: PL 00 PLUMBING P IT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 0 ------------------------------------------------------------------------------------------------ PL6 01 12/05/13 PB PLUMBING WATER SUPPLY 12/06/13 AP December 5, 2013 9:39:26 AM pbarthol. December 6, 2013 9:14:17 AM pbarthol. PL2 01 2/26/14 JLL PLUMBING ROUGH-IN 2/26/14 AP February 26, 2014 10:53:00 AM pbarthol. John 460-6902 February 26, 2014 3:58:02 PM jlierly. PL99 01 12/19/14LL PLUMBING FINAL December 19, 2014 9:18:25 AM pbarthol. Bruce 912-0079 --------------------- -- - ---------- COMMENTS AND NOTES PREPARED 12/19/14, 9:16:17 INSPECTION TICKET PAGE 5 CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 12/19/14 ------------------------------------------------------------------------------------------------ ADDRESS . : 1402 PENDLEY CT SUBDIV: CONTRACTOR : PHONE OWNER PAULA HOWELL PHONE PARCEL 06-30-01-8-6-0010-0000- APPL NUMBER: 13-00001025 RES NEW SFR ------------------------------------------------------------------------------------------------ PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------ BL1 01 11/19/13 JLL BLDG FOUNDATION FOOTING 11/19/13 AP November 19, 2013 8:47:43 AM pbarthol. Bruce 912-0079 November 19, 2013 4:14:44 PM jlierly. BL2 01 11/22/13 PB BLDG FOUNDATION STEM WALL 11/22/13 AP November 22, 2013 8:26:42 AM pbarthol. Bruce 912-0079 November 22, 2013 11:27:41 AM pbarthol. BLFD O1 12/03/13 PB BLDG FOUNDATION DRAINAGE 12/04/13 AP December 3, 2013 9:12:17 AM pbarthol. Bruce 912-0079 December 4, 2013 10:43:48 AM pbarthol. DSD O1 12/04/13 PB BLDG DOWN SPOUT DRAINS . 12/04/13 AP December 4, 2013 10:39:18 AM pbarthol. December 5, 2013 9:36:53 AM pbarthol. PW4 01 12/04/13 RV PUBLIC WORKS STORM _ 12/04/13 AP December 4, 2013 9:18:33 AM rvess. _ December 4, 2013 9:18:50 AM rvess. BFF O1 12/13/13 PB BLDG FLOOR FRAMING 12/16/13 AP December 13, 2013 10:38:50 AM pbarthol. BRUCE 912-0079 December 16, 2013 10:15:39 AM pbarthol. BL9 01 1/21/14 PB BLDG SHEARWALL 1/21/14 AP January 21, 2014 9:51:12 AM pbarthol. January 21, 2014 4:47:34 PM pbarthol. BAIR O1 3/07/14 JLL BLDG AIR SEAL 3/07/14 AP March 7, 2014 9:51:20 AM jlierly. March 7, 2014 4:03:53 PM jlierly. BL3 01 3/07/14 JLL BLDG FRAMING 3/07/14 AP March 7, 2014 9:51:35 AM jlierly. March 7, 2014 4:03:53 PM jlierly. BLI O1 3/19/14 JLL BLDG INSULATION 3/19/14 AP March 19, 2014 10:14:20 AM pbarthol. Bruce 912-0079 March 19, 2014 4:21:49 PM jlierly. PW99 01 12/16/14 RV PUBLIC WORKS FINAL 12/16/14 AP December 16, 2014 2:33:48 PM rvess. December 16, 2014 2:35:01 PM rvess. BL99 01 12/19/14 �IZ,L�f BLDG FINAL December 19, 2014 9:18:10 AM pbarthol. ------------------------- Bruce 912-0079 PERMIT: ME 00 MECHANICAL PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ ----------------------------------- CONTINUED ONTO NEXT PAGE % CITY OF PORT ANGELES f DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT- BUILDING DIVISION �- 321 EAST 5TH STREET, PORT ANGELES, WA 98362 t,N I Application Number . . . . . 13-00001025 Date 10/29/13 \V Application pin number . . . 052975 Property Address . . . . . . 1402 PENDLEY CT ASSESSOR PARCEL NUMBER: 06-30-01-8-6-0010-0000- REPORT SALES TAX 1 Application type description RES NEW SFR Subdivision Name . . . . . . on your state excise tax form Property use . . . . . . . . to the City of Port Angeles Property Zoning . . . . . . . RS9 RESDNTL SINGLE FAMILY Application valuation . . . . 112868 (Location Code 0$02) - --------------------------------------------------------------------- Application desc 1620 SQ FT SFR ------------------------------------------------------------------- -- Owner Contractor ------------------------ ------------------------ PAULA HOWELL OWNER 2646 S FRANCIS ST PORT ANGELES WA 98362 Permit BUILDING' PERMIT -RESIDENTIAL Additional desc 1620 SQ FT SFR Permit Fee . . . . 1093.05 Plan Check Fee 710.48 Issue Date . . . . 10/29/13 Valuation . . 112868 Expiration Date 4/27/14 Qty Unit Charge Per Extension BASE FEE 1020.25 13.00 5.6000 THOU BL-100,001-500K (5.60 PER K) 72.80 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL PERMIT Additional desc . Permit Fee . . . . 141.60 Plan Check Fee .00 Issue Date . . . . 10/29/13 Valuation . . . . 0 Expiration Date 4/27/14 Qty Unit Charge Per Extension BASE FEE 50.00 1.00 14.8000 EA ME-FURN/HP/FAU < OR = 5 TON 14.80 3.00 7.2500 EA ME-VENT FAN (SINGLE DUCT) 21.75 1.00 10.6500 EA ME-HOOD/DUCT-MECH. EXHAUST 10.65 3.00 14.8000 EA ME-HEATER(SUSP/WALL/FLOOR-MTD) 44.40 ---------------------------------------------------------------------------- Permit . . . . . . PLUMBING PERMIT Additional desc . Permit Fee . . . . 163.00 Plan Check Fee .00 Issue Date . . 10/29/13 Valuation . . . . 0 Expiration Date 4/27/14 Qty Unit Charge Per Extension BASE FEE 50.00 8.00 7.0000 EA PL-PLUMBING TRAP 56.00 0_ 1.00 7.0000 EA PL-WATER LINE 7.00 4.00 7.0000 EA PL-DRAIN VENT PIPING 28.00 Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within.180 days,if construction.or work is suspended or abandoned for a period of 180 days after the work has commenced,or if required-inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or.not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the.performance of construction. Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder) T:Forms/Building Division/Building Permit BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS-- Building Inspections 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention inspections 417-4886 IT IS UNLAWFUL.TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type 7 Date Accepted By Comments FOUNDATION: .Footings Stemwall Foundation Drainage/Downspouts Piers Post Holes(Pole Bldgs.) PLUMBING: Under Floor/Slab Rough-In Water Line(Meter to Bldg) Gas Line Back Flow/Water FINAL Date Accepted b AIR SEAL: Walls Ceiling FRAMING: Joists/Girders/Under Floor Shear Wall/Hold Downs Walls/Roof/Ceiling Drywall(Interior Braced Panel Only) T-Bar INSULATION: Slab Wall/Floor/Ceiling MECHANICAL: Heat Pum /Furnace/FAU/Ducts Rough-In Gas Line Wood Stove/Pellet/Chimney Commercial Hood/Ducts FINAL Date Accepted b MANUFACTURED HOMES: Footing/Slab Blocking&Hold Downs Skirting 6 PLANNING DEPT. Separate Permit#s SEPA: Parking/Lighting ESA: Landscaping SHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE Inspection Type Date Accepted By Electrical 417-4735 Construction-R.W. PW /Engineering 417-4831 Fire 417-4653 Planning 417-4750 Building 417-4815 T:Forms/Building Division/Building Permit CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY& ECONOMIC DEVELOPMENT- BUILDING DIVISION - 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Page 2 Application Number . . . . . 13-00001025 Date 10/29/13 Application pin number . . . 052975 REPORT SALES TAX Qty Unit Charge Per Extension our state excise tax form 1.00 15.0000 EA PL-SEWER LINE 15.00 On Y 1.00 7.0000 EA PL-WATER HEATER 7.00 to the City of Port Angeles ------- ------------ ------------------- Special Notes and Comments Location Code 0502) September 17, 2013 7:20:38 AM rbecker. Are you installing a lawn sprinkler system? If you are you will need to install a double check valve assembly_. If you have any questions call Ron Becker at 360-417-4886, fax:360-452-4972, or e-mail:rbecker@cityofpa.us Address numbers shall be plainly visible from the street. Address numbers shall be a minimum of six inches high and be of contrasting color from the background. All homes in new subdivisions that are outside of the Fire Department four-minute response area shall be equipped with residential fire sprinkler systems that comply with the International Fire Code (IFC_) and National Fire Protection Association (NFPA) . September 13, 2013 4:22:15 PM banders. Electrical connection point is at the southeast corner of property. Electrical load calculations and electrical permits are required. Consider applying for the City Green Infrastructure Rebate of up to $500.00 towards the materials to install rain garden to control roof and driveway runoff. Contact Jonathan Boehme at 360 417-4811 Trench safety per applicable laws. Temp erosion control and surface restoration responsibility of applicant. Contact City inspector prior to start of work @ 36b'417-4831. No attachment to sanitary sewer of stormwater roof leaders, foundation drains, yard drains, or any other CSO contribution is allowed. Sanitary sewer connection inspection is required by Public Works prior to back fill of ditch. 24 hour advance notice is required. Public Works Inspection request line 417-4831 Construct driveway to City Standards. Concrete -with exposed aggregate or other non-standard finishes(including colors or dyes)are not allowed in the City road right of way. Broom finish only. An inspection by Public Works Engineering is required prior to pouring concrete. Public Works inspection request line 417-4831 Ditches & 12". culverts will be installed to City Stanards. See Public Works Engineering for Standards. ---------------------------------------------------------------------------- Othe1r Fees . . . . . . . . . RES UNDERGRND SERVICE FEE 770.00 SEWER SYSTEM DELV CHARGE 2260.00 STATE SURCHARGE 4.50, PW WATER SYSTEM USE FEE 2260.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180,days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced, or if required'inspectidns have'not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the.performance of construction. Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder) T:Forms/Building Division/Building Permit P - BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS-- Building Inspections. 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL.TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION: Footings Stemwall Foundation Drainage/Downspouts Piers Post Holes(Pole Bldgs) PLUMBING: Under Floor/Slab Rough-in Water Line(Meter to Bldg) Gas Line Back Flow/Water FINAL Date Accepted b AIR SEAL: Walls Ceiling FRAMING: Joists/Girders/Under Floor Shear Wall/Hold Downs Walls/Roof/Ceiling Drywall(Interior Braced Panel Only) T-Bar INSULATION: Slab Wall/Floor/Ceiling MECHANICAL: Heat Pum /Furnace/FAU/Ducts Rough-in Gas Line Wood Stove/Pellet/Chimney Commercial Hood/Ducts FINAL Date Accepted by. MANUFACTURED HOMES: Footing/Slab Blocking&Hold Downs Skirting PLANNING DEPT. Separate Permit#s SEPA: Parkin /Lighting ESA: Landscaping SHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE Inspection Type Date Accepted By Electrical 417-4735 Construction-R.W. PW I Engineering 417-4831 Fire 417-4653 Planning 417-4750 Building 417-4815 T:Forms/Building Division/Building Permit CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY& ECONOMIC DEVELOPMENT- BUILDING DIVISION 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Page 3 Application Number 13-00001025 Date 10/29/13 Application pin number . . . 052975 ----------------- ---------- --------- --------- --- REPORT SALES TAX Permit Fee Total 1397.65 1397.65 .00 .00 Plan Check Total 710.48 710.48 .00 .00 on your state excise tax form Other Fee Total 5294.50 5294.50 .00 .00 to the City of Port Angeles Grand Total 7402.63 7402.63 .00 .00 (Location Code 0502) Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced.within 1 80days,if construction or-work is suspended or abandoned for a period of 180 days after the work has commenced,or if required-'inspections have not been-requested within 180 days from the last inspection. 1 hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder) T:Forms/Building Division/Building Permit BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS— Building Inspections. 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL_TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION: Footings Stemwall Foundation Drainage/Downspouts Piers Post Holes(Pole Bldgs.) PLUMBING: Under Floor/Slab Rough-In Water Line(Meter to Bldg) Gas Line Back Flow/Water FINAL Date Accepted b AIR SEAL: Walls Ceiling FRAMING: Joists/Girders/Under Floor Shear Wall/Hold Downs Walls/Roof/Ceiling Drywall(Interior Braced Panel Only) T-Bar INSULATION: Slab Wall/Floor/Ceiling MECHANICAL: Heat Pum /Furnace/FAU/Ducts Rough-In Gas Line Wood Stove/Pellet/Chimney Commercial Hood/Ducts FINAL Date Accepted b MANUFACTURED HOMES: Footing/Slab Blocking 1£Hold Downs Skirting PLANNING DEPT. Separate Permit#s SEPA: Parking/Lighting ESA: Landscaping SHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE Inspection Type Date Accepted By Electrical 417-4735 Construction-R.W. PW /Engineering 417-4831 Fire 417-4653 Planning 417-4750 Building 417-4815 T:Forms/Building Division/Building Permit OF ORI, tiQ' C( ITY OF PORT ANGELES ( V _FN ��.�.i PUBLIC WORKS & UTILITIES v 321 EAST 5TH STREET, PORT ANGELES. WA 98362 Rai�� Application Number . . . . . 13-00001025 Date 10/29/13 Application pin number . . . 052975 Property Address . . . . . . 1402 PENDLEY CT REPORT SALES TAX ASSESSOR PARCEL NUMBER: 06-30-01-8-6-0010-0000- Application type description RES NEW SFR on your state excise tax form Subdivision Name . . . . Property Use . . . . . . .. to the City of Port Angeles Property Zoning . . . . . . . RS9 RESDNTL SINGLE FAMILY (Location Code 0502) Application valuation . . . . 112868 --------------- Application desc 1620 SQ FT SFR ----------------------------------------------------------------------------- Owner Contractor PAULA HOWELL OWNER 2646 S FRANCIS ST PORT ANGELES WA 98362 ---------------------------------------------------------------------------- Permit . . . . . . DRIVEWAY INSTALLATION Additional desc DRIVEWAY AND 12" CULVERT Permit Fee 180.00 Plan Check Fee .00 Issue Date . . . . 10/29/13 Valuation . . . . 0 Expiration Date . . 4/27/14 Qty Unit Charge Per Extension BASE FEE 180.00 ---------------------------------------------------------------------------- Permit . . . . . . PUBLIC WORKS RES WATER SERV Additional desc 3/4" METER FOR FIRE SPRINKLERS Permit Fee . . . . 420.00 Plan Check Fee .00 Issue Date . . . . 10/29/13 Valuation . . . . 112868 Expiration Date 4/27/14 Qty Unit Charge Per Extension 1.00 420.0000 EA PW WATER METER DROP IN 420.00 ---------------------------------------------------------------------------- Permit . . . . . . SANITARY SEWER HOOK UP Additional desc . . Permit Fee . . . . 150.00 Plan Check Fee .00 Issue Date . . . . 10/29/13 Valuation . . . . 112868 Expiration Date . . 4/27/14 Qty Unit Charge Per Extension 1.00 150.0000 EA SAN SEWER HOOKUP 150.00 ---------------------------------------------------------------------------- Special Notes and Comments September 17, 2013 7:20:38 AM rbecker. Are you installing a lawn sprinkler system? If you are you will need to install a double check valve assembly. If you have any questions call Ron Becker at 360-417-4886, fax:360-452-4972,, or e-mail:rbecker@cityofpa.us Address numbers shall be plainly visible from the street. Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work as commenced,or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. I Iola /i3 Signature of Contract r� Authorized Agent Date Signature of Owner(if owner is builder) Date T:Forms/Building Division/Public Works Permit PERMIT INSPECTION RECORD CALL 417-4831 FOR UTILITY INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INA CONSPICUOUS LOCATION. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED COMMENTS YES NO PW UTILITIES (Engineering Division) WATERLINE/METER SEWER CONNECTION SANITARY STORM SITE DRAINAGE SITE EROSION CONTROL PARKING SIDEWALK CURB&GUTTER DRIVEWAY APPROACH BACK-FLOW DEVICE FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED YES NO CONSTRUCTION R.W./PW/ CONSTRUCTION-R.W. ENGINEERING 417-4807 PW/ENGINEERING FIRE 4174653 FIRE DEPT. PLANNING DEPT. 417-4750 PLANNING DEPT. BUILDING 4b7- BUILDING 4815 T:Forms/Building Division/Public Works Permit QF PORT,N,C SwF. CITY OF PORT ANGELES PUBLIC WORKS & UTILITIES 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Page 2 Application Number . . . . . 13-00001025 Date 10/29/13 Application pin number . . . 052975 ------------------------------------------------------------ REPORT SALES TAX Special Notes and Comments on your state excise tax form Address numbers shall be a minimum of six inches high and be of contrasting color from the background. to the City of Port Angeles All homes in new subdivisions that are outside of the Fire (Location Code 0502) Department four-minute response area shall be equipped with residential fire sprinkler systems that comply with the International Fire Code (IFC) and National Fire Protection Association (NFPA) . September 13, 2013 4:22:15 PM banders. Electrical connection point is at the southeast corner of property. Electrical load calculations and electrical permits are required. Consider applying for the City Green Infrastructure Rebate of up to $500.00 towards the materials to install rain garden to control roof and driveway runoff. Contact Jonathan Boehme at 360 417-4811 Trench safety per applicable laws. Temp erosion control and surface restoration responsibility of applicant. Contact City inspector prior to start of work @ 360 417-4831. No attachment to sanitary sewer of stormwater roof leaders, foundation drains, yard drains, or any other CSO contribution is allowed. Sanitary sewer connection inspection is required by Public Works prior to back fill of ditch. 24 hour advance notice is required. Public Works Inspection request line 417-4831 Construct driveway to City Standards. Concrete with exposed aggregate or other non-standard finishes(including colors or dyes)are not allowed in the City road right of way. Broom finish only. An inspection by Public Works Engineering is required prior to pouring concrete. Public Works inspection request line 417-4831 Ditches & 12" culverts will be installed to City Stanards. See Public Works Engineering for Standards. ---------------------------------------------------------------------------- Other Fees . . . . . . . RES UNDERGRND SERVICE FEE 770.00 SEWER SYSTEM DELV CHARGE 2260.00 STATE SURCHARGE 4.50 PW WATER SYSTEM USE FEE 2260.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 750.00 750.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 5294.50 5294.50 .00 .00 Grand Total 6044.50 6044.50 .00 .00 Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work as commenced,or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Signature of Contractor or Authorized Agent Date Signature of Owner(if owner is builder) Date T:Forms/Building Division/Public Works Permit PERMIT INSPECTION RECORD CALL 417-4831 FOR UTILITY INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. ITIS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INA CONSPICUOUS LOCATION. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED COMMENTS YES NO PW UTILITIES (Engineering Division) WATERLINE/METER SEWER CONNECTION SANITARY STORM SITE DRAINAGE SITE EROSION CONTROL PARKING SIDEWALK CURB&GUTTER DRIVEWAY APPROACH BACK-FLOW DEVICE FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED YES NO CONSTRUCTION R.W./PW/ CONSTRUCTION-R.W. ENGINEERING 417-4807 PW/ENGINEERING FIRE 417-4653 FIRE DEPT. PLANNING DEPT. 417-4750 PLANNING DEPT. BUILDING 47- BUILDING 4815 T:Forms/Building Division/Public Works Permit THE ''YL CETY OF ° .� NGo -E , E For City Use ,.� Permit# i'3 -I O 2'< W A, S H I N G T O N , U . S . Date Received: 0 - �J 321 East 51 Street Port Angeles, WA 98362 ate Approved J P: 360-417-4817 F: 360-417-4711 J permits@cityofpa.us Building Permit Application Project Address: / 4/o ,2, CvL)fe-r /9 jq_ c.,.dg. �g3G3 Main Contact: c o1/5-rg u o•,! s ue9g,e v 1se2 Phone # 9i 2 - o l 9 j'S1v1.✓sUL4 Nc os;n/61- quT1.1 oal-ry E-Mail: bmcc© Property Name Phone Owner q uk it f-'``f t)-[- Mailing Address Email ; I y& S, 577- city State Zip Contractor Name Phone V1,4 Qg.k Mailing Address Email City State Zip Contractor License # Expiration: Project Value: Zoning: Tax Parcel # Lot# $ 112 g6 'g Type of Residential Commercial ❑ Industrial ❑ Public ❑ Permit Demolition ❑ Fire ❑ Repair ❑ Reroof(tear off/lay over) ❑ For the following,fill out both pages of permit application: New Construction 2' Remodel ❑ Addition ❑ Tenant Improvement ❑ Mechanical ❑ Plumbing ❑ Other ❑ Existing Fire Sprinkler System? Maximum height of structureProposed Bedrooms Proposed Bathrooms Yes 13 No 13 /(, /=T 3 ;7, Project gW SinlG��- Description 2� I I have read and completed the application and know it to be true and correct.I am authorized to apply for this permit. I understand that it is my responsibility to determine what permits are required and to obtain permits prior to working on projects. I understand that the plan review fee is not refundable after plan review has occurred. I understand that I will forfeit the review fee if I cancel or withdraw the application before the permit is issued. I understand that if the permit is not issued within 180 days of receipt,the application will b' considered abandoned and the fees forfeit. Date Print Name Signature �R v c � � c C�P� ��✓ C�,�� Residential Structures For Office Use Area Description (SQ FT) Existing Proposed $$value Basement First Floor Second Floor Covered Deck/Porch/Entry 4,r j p c g Deck 4 t Garage 3 yv %O � oc7 Carport Other(describe) Area Totals / j n g Commercial Structures For Office Use Area Descriptions (SQ FT) Existing Proposed $$Value Existing Structure (s) Proposed Addition Tenant Improvement? Other work(describe) Area Totals Lot/Site Coverage Calculations Footprint(SQ FT) of all Structures: Lot Size: %Lot Coverage / �.d ures: a v 90 91 SQ FT Site coverage (all impervious+ %Site Coverage structures _ �0 n a y. 7 Mechanical Fixtures Indicate how many of each type of fixture to be installed or relocated as part of this project. Air Handler Size: # Haz/Non-Haz Piping #of Outlets: Appliance Vent # Heater(Suspended,Floor,Recessed wall) # Boiler/Compressor Size: # Heating/Cooling appliance # repair/alteration Evaporative Cooler(attached,not # Pellet Stove/Wood-burning/Gas # portable) Fireplace/Gas Stove Gas Cook Stove/Misc. Fuel Gas Piping #of Outlets: Ventilation Fan,single duct # Furnac eat Pum' Size: # Ventilation System # Forced Air Unit d 1 U Plumbing Fixtures Indicate how many of each type of fixture to be installed or relocated Plumbing Traps # Fuel gas piping #of Outlets: Water Heater # Medical gas piping #of Outlets: Water Line # Vent piping # Sewer Line # / Industrial waste pretreatment # interceptor Other describe T:\BUILDING\APPLICATION FORMS\BUILDING PERMIT 081212.DOCX of vowr,i.. W Electrical Information Form E M Public Works&Utilities Department(360)417-4700 `�'��F` City Electrical Inspector(360)417-4735 3 . `IpRK56UT Please complete and return to Public Works& Utilities Department Permanent service: Name: /' v�-,+� z Name and address of party Street: �y� 5, �1'�P�n/et5 5; responsible for permanent City I State! ZIP: �a2T �,�/G L;L�S c,�t}, Z service billing? Daytime Phone: Home Phone: 7Site • (if other than above) ontact: Name: 13JetJf- Mc t?6 A .✓JO� Title- C_0.6 ST. ,5th�°£,�V l��� Daytime Phone: ?,/A— Do's p Contractor: Name: of-id ep. - a of A v /Z &J/Company: PiW I sd5Vj_A HtYU,5t,16'- ti ara. Daytime Phone: Electrician: Name: Company: Daytime Phone: Excavator: Name: Company: Daytime Phone: • ` ❑Existing ew Single-family residence ❑Multi-family residence; #of units ❑Commercial El Subdivision;#of lots ❑Overhead service ❑General service Underground service ❑Other: • . • I= Description of work: 19/gsal USfo 1.4e_!,c Street address/lot number: /VC)a IvD)..Z. C00 i �o Nearest cross street: Z,5-r / 77i S'r. Desired connection date: Electrical transformer serving property is: ❑on a pole on the ground Total square footage: _ / Esq.ft. Main disconnect size: O o amps Voltage: EI'120/240 1ph 0120/208 3ph ❑277/480 3ph ❑12 240 3ph ❑480 3W 3ph ❑ Other Standard residential loads (Lighting, refrigerator, dishwasher, washer) Check all that apply: ❑A/C (—ton) E,—�,��ange/Oven ❑Hot Tub Clothes Dryer Li-Fieating ❑Pumps (_Hp) ❑No Load Change EKater Heater ❑Elevator(_Hp) ❑Other ' ' ' ' • Please provide a copy of the following: 'Detailed plot plan (.dwg or.dxf format mandatory for subdivisions). `Electrical one-line drawing showing the service entrance panel and location. *Connected load data. 'Size and locked rotor amps of all motors over 50hp. Applicant's Signature: Date: MAIL OR DELIVER COMPLETED FORM TO: 321 E 5TH STREET; PORT ANGELES, WA 98362 FAX TO: 360-417-471 WS WF Information form.xls c ' PORT,+%,CF PRESCRIPTIVE APPROACH-SIMPLE FORM INE==—V For the Washington State Energy Code (WSEC) 2009 Edition - - Climate Zone 1 CRY GOVERNMENT Site Information: Building Department Use Only: Lot: /�f�p f,2-r Permit # Address: /Y o�- 10g.N p)-r-y eoyR i Notes: City: /c R2 - State: t t.,Vq Zip: y 8 3 � 3 Contact: Phone: Phone 2: FAX: WSEC Table 6-1 PRESCRIPTIVE REQUIREMENTS FOR SINGLE-FAMILY RESIDENTIAL OR DUPLEX CLIMATE ZONE 1 (Unlimited Glazing Option Only) Glamg Glazing Ufactor- Door K, Wall Wall: Wall O tion ' , Area% of I Vaulted Interior Exterior Slab on` P U Ceiling Above Floor yFloorr4; ,Vert%cal Overhead Factor Ceiling d Belowt Below Concrete. Gra e ,_�� , ..� � �Y _ = Grade Grade ��� t R-49 III /Unlimited 0.30 0.50 0.20 or R-38 R-21 R-21 R-10 R-30 R-10 R-38 int TB U=0.029 2' adv This Project complies with the following: The project is a single-family residence or duplex. The project is a wood frame OR all of the insulation is interior or exterior of the framing. All building components meet the requirements listed above. The project will meet all other provisions of the WSEC and VIAQ. The Project will take advantage of the following exceptions to the prescriptive option. ❑ 602.6 Exception 2. One unlabeled or untested exterior swinging door, 24 sq.ft. or less, may be installed per unit for ornamental, security, or architectural purposes. Location of the door taking this exception: ❑ 602.6 Exception 2. If a door is mostly glass, it should meet the requirement of the vertical glazing U-factor listed above. Location of the door(s)taking exception: M/N,-se4(-r cdc�r464L Type of Heat Source: 1DV&rJ_ 93S 3 T:Forms/Building Division/Prescriptive Approach-Simple Form S33�14t 1"I,� �Lo•�DN L Q UN - m 4'rP PF FtG CAN IN TD In I-IoIJt I LQ X • � 252.5' � I � Site PLan P=200 140'2 PSN ID Lam- coLJ I9T EWO PORT ANGELES,VA 98363 COUNTY Of CL4LL4m PLOLEY COUZT LILT"I LOT COVERA�E 1620/90086f = 1896 51TE COVERAC'E 2228/90085F = 2A796 LIOU6L STYLE.T11E'-")dQL4 Pe 61seA -to be Ry Co r-) 35' 35' I FND. i"CONDUIT WITH PLASTIC CAP FND. 1" CONDUIT WITH PLASTIC CAP I 35' I 35' 23" "CLARK 122 ,—508:30.15"W, STAhIPED "'CLARK 12223", N87-54'21"W. STAMPED � 021'FROM CALCULATED POS17ION 0.27'FROMCA!'CULATED POSITION. \I N 33'14'39"E 669.64 8' 95;00 53.00' 106.65' 76.00'N 81.00' 85.60' /85.80' 86.60' HOUR 10' — — NY I�t cNn• cNn 10' — 10' u! cNn c�'n cNn 1 `8 �L� �/9 IyoZNTJ. 11F FND. 2"E9016 O.FT. +� 9011 SQ-FT.�F90FA F 7 pa-9904 T 39 SQ. 008 SOF025 SQ.FT O+ 2o+ � a9003 SQ.FT. CIEDN WTH PL 10288 SQ.FT ub 18' rn 2N42& 1 � �L BB 95M—I �jGS> 4 oI5 / ' ' B S33'I440 W 8-135 u, 0218 34 42 85.c2 :6 66:.....1. ..........:::16 ' . 6 ............................... m _.... 5.2303 E _ N 32 50104'15" : .. ... N ;;;:r.16 : . NN 27'58 co) 025 '1415S 33 C 143 5 56.07 C . cls : "E--."'.•'.-'.:'.-':.:.•'...�:.:u.�,r'.:..:_:.':.ooo> —�I cm.;•ume`w° m covRr J 10\ Q•.. r.{ i::::.:r'..;:,o?. Cil.C14..:.::,:. 72.67, Mal 74.75' p 0 0� /10.61' 72.N3" — l8533'14 42 W �L O) S� C I 21 NI 10' o I 2FFND. I 2"REBAR WITH r25 2� 3.. 11 — u, 10 m 13 14 18' / •b b_ 10781 SQ.FT. 8• V°i 9053 SQ.FT N I 'o n 9007 SQ.FT. b 9006 SQ.FT. `O�'9015 SQ.FT y; In N 3. PLASTIC CAP 0.14'FROM cn 15 o d a 9031 SQ.FT. 1 r CALCULATED POSITION o 90'15 SO.F1I o p ,o^/— 9 'o u'�1 krn PJ O `m i'I ® m�� I �' I u, m 9042 SQ,FT. ? // o rn v STAMPED "CUMMINS LS `° �•' • 10' — - 10' — ---� ' 22329", N60'02'30'•E. o a \ � — . —/vtY_ �� � —I �� _LH IQ— y01 3500 78.64' 109.02' u'• 83.25' 77.75' / 74.77 i� 75.38 75./85' I FND. CAP I N 33'14'44" E N 669.66' / N 0630( SE COR. FOUND I/2•'REBAR AND o FND. 1"CONDUIT WITH PLASTIC CAP SUB LOT 79 - CAP "Z&A PLS 28071" STAMPED "CLARK 12223", 56522'58"W, I al 0.18'FROM CALCULATED POSITION CI b A 2013-1301868 Warranty Deed PagBe 1 of 2 Dlympio Peninsula Title Company 125!2073 00:76:38 Ph Clallam County Washington 10 mill Fed%rI#A MWL*bB�}cml o,:olWIlk 11111 �1011*04 OLYMPIC PENINSULA Title Company No CLALn7G O Cj OU Y TRANSACTION EXCI TAX DATE PAID OCT 25 20 AIMOUNT c5�, v COUNTYTRFA Escrow Number:101420-DS BY Statutory Warranty Deed THE GRANTOR Housing Authority of the County of( for and' c e 'ono E OLLARS AND OTHER GOOD AND VALUABLE CONSIDERATION in ban p Id,con s nd w to Paula Howell,an unmarried individual the following described real estate,si at d in the Co n of Clallam,State of Washington. Abbreviated Legal: LOT 1,PENDLEY ESTATES, For Full Legal See Attached Exhibit"A" Subject to exceptions to title also appearing on Exhibit" Tax Parcel Number(s):06-30-99-107910/70 6-30-01-860010/82921(New Assigned Parcel No.) Dated October 21,2013 using Authority of the o Clallam By:Pamela J.Ti ecutive Director O STATE OF W S INGJ-ON, } COUNTY OF C ALLATO SS: 1 certify thatk ow r e s ' factory vidence that Pamela I Tietz 1 are the person(s) who appeared before me,and said pe n(s knowledkeAat she signed this instrument,on oath stated she is/are authorize e �ut e instrument and acknowledge that as the Exec irecta of Housing Authority of th Count of Clallam to be the fr n lun act f such party(ies)forth purpos io d in this ins t. Dated: c ober lay 2 13 \ " �ingg*uat r and for the State of Washington Angeles My appointment expires: 4-9-2015 s r - LPB 10-05(i-1)o2 Page 1 of 2 J 2013-1301868 10/25/2013 04:16:38 PM 2 of 2 Clallam County, WAWD t _ OLYMPIC PENINSULA TITLE COMPANY i EXHIBIT A LOT I OF PENDLEY ESTATES,AS PER PLAT THEREOF RECORDED IN VOLUI IE IS OF PLATS,PAGE 78,RECORDS OF CLALLAM COUNTY,WASHINGTON. O SITUATE IN CLALLAM COUNTY,STATE OF WASHINGTON. SUBJECT TO: 1. ALL COVENANTS,CONDITIONS,RESTRICTIONS,RESERVATIONS,EASEME R OTHER SERVITUDES,IF ANY,DISCLOSED BY THE RECORDED PLA 0 ESTATES. 2. ALL COVENANTS,CONDITIONS,RESTRICTIONS,RESERVATIO4ENTS OR OTHER SERVITUDES,IF ANY,DISCLOSED BY SHORT PLAT RE RRCLALLAM COUNTY RECORDING NO.515919. 3. COVENANTS,FOR MAINTENANCE,REPAIR AND OPERATION 0INAGE FACILITIES,CONDITIONS AND RESTRICTIONS IMPOSED ORDED UNDER CLALLAM COUNTY RECORDING NO. 2013-129 0 0 JPago 2 of 2 L ALS iI �>S�� �1 i � I i 1 I�; j� —r�j � � l 1 � i � j-`�l(�z+--- L-H-Al if NV� tz if ! 1 I + } � I i � } ! I ! _j +�-ice j � { i � ! � ! 7 A, IH Lj ei . is 71 4--,L � +- ' i i i I If IL ON. it XIA Milli , i ' M I I -- ---------- IN I A6.. :2K 3 DI I 1 j- I I i ; i i { j i - 41 -4--t I L FUL Ir us If kLL 44- 1 --4- j 41- it 0 4(! it Z-i -- ----------- 7 7-L )IV- "-YV _T7 ji -fir ' I Li- �'�rf ----------- T11 V- 1;L j F 7 Ic T —A — ,Z_! F jT Li Ili 1 '7. ' i � � ' I j j I i I 1 I � I I�- I ' I I � +}---�--t--)�- I � -- I 49�e, % 1/21 zd _jz- J—I Ip -ILL Li ice- G �✓u_o } -' 71 ov I �—; �—�---t—•1 �--i----� ��-�, j � � _t_ 7 71 -----t I --TT- jl ! T , -r-) I �--�--+ j + I ( � j i 1 j_ I �=i---f- f � ��L__I_-�-✓I—� i/ G-l����-)-L-� T 41, i 07 z;�z` �L (eZ�e L.oivu L-] ----7-11 j l �fiiJ" 1 77_1 X-7� ll�ts- CGI-TIa�s ? ��2 !25_� '���' j` _ ! t-� I i I_I � i L i_ *Fi . ......... K-AYOLL 4 �Kp A6 L.1 J'l a I I I t MECAWind Version 2 . 1 . 0 . 5 per ASCE 7-05 Developed by MECA Enterprises, Inc. Copyright 2012 www.mecaenterprises.com Date 10/16/2012 Project No. 12176 Company Name ZENOVIC & ASSOCIATES, INC. Designed By SRH Address 301 EAST 6TH STREET, SUITE 1 Description 28x40 SFR City PORT ANGELES Customer Name PENINSULA HOUSING AUTHORITY State WA Proj Location CLALLAM COUNTY, WA File Location: X:\12176 HOUSING AUTHORITY\ENGR\Structual\SFR DESIGN C.wnd Detailed Wind Load Design (Method 2) per ASCE 7-05 Basic Wind Speed(V) = 100.00 mph Structure Type = Building Structural Category = II Exposure Category = C Natural Frequency = N/A Flexible Structure = No Importance Factor = 1.00 Kd Directional Factor = 0.85 Alpha = 9.50 Zg = 900.00 ft At = 0. 11 Bt = 1.00 Am = 0. 15 Bm = 0.65 Cc = 0.20 1 = 500.00 ft Epsilon = 0.20 Zmin = 15.00 ft Slope of Roof = 4 : 12 Slope of Roof(Theta) = 18.43 Deg Ht: Mean Roof Ht = 10.00 ft Type of Roof = Gabled RHt: Ridge Ht = 12.00 ft Eht: Eave Height = 8.00 ft OH: Roof Overhang at Eave= .00 ft Roof Area = 1316.00 ft^ 2 Bldg Length Along Ridge = 52.00 ft Bldg Width Across Ridge= 24.00 ft Gust Factor Category I Rigid Structures - Simplified Method Gustl: For Rigid Structures (Nat. Freq.>1 Hz) use 0.85 = 0.85 Gust Factor Category II Rigid Structures - Complete Analysis Zm: 0. 6*Ht = 15.00 ft lzm: Cc* (33/Zm) ^0.167 = 0.23 Lzm: 1* (Zm/33) ^Epsilon = 427.06 ft Q: (1/ (1+0. 63* ( (B+Ht) /Lzm) ^0. 63) ) ^0.5 = 0. 94 Gust2: 0. 925* ( (1+1.7*lzm*3.4*Q) / (1+1.7*3.4*lzm) ) = 0.89 Gust Factor Summary Not a Flexible Structure use the Lessor of Gustl or Gust2 = 0.85 Figure 6-5 Internal Pressure Coefficients for Buildings, GCpi GCPi : Internal Pressure Coefficient = +/-0.18 Figure 6-6 External Pressure Coefficients Cp - Loads on Main Wind-Force Resisting Systems(Method 2) beta h L Z 4� -i I B B Kh: 2.01* (Ht/Zg) ^ (2/Alpha) = 0.85 Kht: Topographic Factor (Figure 6-4) = 1.00 Qh: .00256* (V) ^2*I*Kh*Kht*Kd = 18.47 psf Cpww: Windward Wall Cp(Ref Fig 6-6) = 0.80 Roof Area = 1316.00 ft^2 Reduction Factor based on Roof Area = 0.80 MWFRS-Wall Pressures for Wind Normal to 52 ft wall (Normal to Ridge) Wall Cp Pressure Pressure +GCpi (psf) -GCpi (psf) --------------- ------ ----------- ----------- Leeward Wall -0.50 -11.18 -4.53 Side Walls -0.70 -14.32 -7.67 Wall Elev Kz Kzt qz Press Press Total Shear Moment ft psf +GCpi -GCpi +/-GCpi Kip K-ft -------------------------------------------------------------------------------- Windward 12.00 0.85 1.00 18.47 9.24 15.89 20.41 12.74 76.42 Note: 1) Total = Leeward GCPi + Windward GCPi 2) Shear and Moment are sum of forces (Leeward+Windard) acting on bldg walls. Note that the shear & moment don't consider loads on roof or end gable. Roof Location Cp +GCpi(psf) -GCpi(psf) ----------------------- ------- ---------- ---------- Windward - Min Cp -0.45 -10.39 -3.74 Windward - Max Cp 0.01 -3.17 3.48 Leeward Perp to Ridge -0.57 -12.27 -5.62 Overhang Top (Windward) -0.45 -7.07 -7.07 Overhang Top (Leeward) -0.57 -8.95 -8.95 Overhang (Windward only) 0.80 12.56 12.56 MWFRS-Wall Pressures for Wind Normal to 24 ft wall (Along Ridge) Wall Cp Pressure Pressure +GCpi (psf) -GCpi (psf) --------------- ------ ----------- ----------- Leeward Wall -0.29 -7.90 -1.25 Side Walls -0.70 -14.32 -7.67 Wall Elev Kz Kzt qz Press Press Total Shear Moment ft psf +Ojai -GCpi +/-GCpi Kip JK-ft -------------------------------------------------------------------------------- Windward 12.00 0.85 1.00 18.47 9.24 15.89 17.14 4.94 29.62 Note: 1) Total = Leeward GCPi + Windward GCPi 2) Shear and Moment are sum of forces (Leeward+Windard) acting on bldg walls. Note that the shear & moment don't consider loads on roof or end gable. Roof - Dist from Windward Edge CP Pressure Pressure +GCpi(psf) -GCpi(psf) --------------------------------- ------ ---------- ---------- 0.0 ft to 5.0 ft -0.90 -17.46 -10.81 5.0 ft to 10.0 ft -0.90 -17.46 -10.81 10.0 ft to 20.0 ft -0.50 -11.18 -4.53 20.0 ft to 52.0 ft -0.30 -8.04 -1.39 Pet1mcriptive Energy Code Compliance for Single Family and Duplex Housing: Zone 1 Project Information Contact Information Pendley Courter Q Peninsula Housing Authority Port Angeles, WA 2603 S Francis St Clallam County Port Angeles, WA 98362 This set of forms has been developed to assist permit applicants documenting compliance with the Washington State Energy Code, (2009 edition). This set is for structures built under the I.RC and located in Climate Zone 1. The following forms provide much of the required documentation for plan review. The details noted here must also be shown on the drawings(WSEC 104.2). This form is not a substitute for the energy code itself. To obtain a copy of the energy code, go to the following web address. http://www.energy.wsu.edu/code Glazing Glazing U-Factor Door 9 Vaulted Option Area Wall" Wall- into Wall ext4 5 Slabb Ceiling2 3 Above Below Below Floor on %of Floor Vertical Overhead" U-Factor Ceiling Grade Grade Grade Grade R-49 or 0 1 R-2 OI 13% 0.34 0.50 0.20 R-38 R-38 1 R-21-21 -2nt.' TB R-10 R-30 R-1-1 Adv. R-49 or R-21 R-21 R-10 011 25% 0.32 0.50 0.20 R-38 R-38 Int. TB R-10 R-30 2 Adv. R-49 or R-21 R-21 R-10 Q III Unlimited 0.30 0.50 0.20 R-38 R-38 Int. TB R-10 R-30 2 Adv: See WSEC table 6-1 for footnotes Glazing Schedule Attached to Document Does not apply. (SEE INSTRUCTIONS) Using Prescriptive Option III. All glazing and doors meet maximum U-factor.Alternate heating size method submitted. ❑ Option I or II, Glazing to floor area limit(WSEC 602.7.2) ❑ Area weighted window,skylight or door,U-factor.(WSEC 602.7.2) ❑ As part of the heating system sizing calculation (IRC M1401.3 &WSEC 503.2.2) Radiant slab: ❑ R-10 foam insulation, continuous with thermal break (WSEC 502.1.4.9) Chapter 9 Options Total of 1 Credit Required Opt. Opt. Description 1a High Efficiency HVAC Equipment 1 ❑ _1b High Efficiency HVAC Equipment 2 1c High Efficiency HVAC Equipment 3 ❑ 2 High Eff ciency HVAC Distribution System ❑ 3a Efficient Building Envelope 1 ❑ 3b Efficient Building Envelope 2 ❑ 3c Super-Efficient Building Envelope 3 ❑ 4a Air Leakage Control and Efficient Ventilation ❑ . 4b Additional Air Leakage Control and Efficient Ventilation ❑ 5a Efficient Water Heating ❑ 5b High Effieciency Water Heatin ❑ 6 Small Dwelling Unit 1.0 0 7 Large Dwelling Unit ❑ . 8 Renewable Electric Ener *1200 kwh ❑ Total Credits 1.00 WSEC Prescriptive Worksheet(2010 edition)Zone 1 WSUEEPI 0-010 Copyright 2010 Sim�aJle Heating System Size: Climate Zone 1 Project Information Contact Information Pendley Court Peninsula Housing Authority "The Sheila" 2603 S Francis St Port Angeles, WA 98363 Port Angeles, WA 98362 Indoor Design Temperature 70 Outdoor Design Temperature 28 Design Temperature Difference (AT) AT=Indoor-Outdoor.Design Temp .42 Conditioned Floor Area 1 1240 Conditioned Volume 1 9920 Glazing Copy Sum of UA from Glazing Schedule 0 Attic U-Factor X Area = UA R-49 0.027 1240 33.5 R-38 Advanced 0.026 Single Rafter or Joist Vaulted Ceilings U-Factor X Area = UA. R-38 Vented 0.027 Above Grade Walls U-Factor X Area = UA R-21 0.056 1288 72.1 Floors U-Factor X Area = UA R-30 0.029 1240 36.0 Below Grade Walls U-Factor X Area = UA 2' Depth Walls 0.042 3.5' Depth Walls 0.041 7' Depth Walls 0.037 Slab Below Grade F-Factor X Length = UA 2' Depth 0.59 3.5' Depth 0.64 7' Depth 0.57 Slab on Grade F-Factor X Length _ UA R-10 2' perimeter 0.54 R-10 Full - Heated 0.55 Sum of UA 142 Envelope Heat Load 5946 Btu/Hour Sum of UA X AT Air Leakage Heat Load 4500 Btu/Hour ((Volume X 0.6)X AT)X.018)) Building Design Heat Load 10446 Btu/Hour Air Leakage+Envelope Heat Loss Building and Duct Heat.Load 0 104461 Btu/Hour If ducts are located in unconditioned space:Sum of Building Heat Loss X 1.15 If ducts are located in conditioned space:Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 150% 15668 Btu/Hour Building,and Duct Heat Loss X 1.50 WSEC Prescriptive Worksheet(2010 Edition) WSUEEP10-010 Copyright 2010