HomeMy WebLinkAbout1410 Morning Court Address:
1410 Morning Court
( � I ) /V1 t, rv\�'Tv C/ _ C '0-
PREPARED 4/15/15, 10:33:44 INSPECTION TICKET PAGE 2
CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 4/15/15
ADDRESS . : 1410 MORNING CT SUBDIV:
CONTRACTOR : PHONE
OWNER GREEN CROW PROPERTIES INC PHONE
PARCEL 06-30-14-6-7-0420-0000-
APPL NUMBER: 14-00001109 RES NEW SFR
------------------------------------------------------------------------------------------------
PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
BL1 01 10/08/14 JLL BLDG FOUNDATION FOOTING
10/09/14 AP October 8, 2014 9:04:45 AM pbarthol.
Adam 460-7079
October 9, 2014 9:34:49 AM jlierly.
BL2 01 10/14/14 PB BLDG FOUNDATION STEM WALL
10/14/14 AP October 14, 2014 12:16:18 PM pbarthol.
October 14, 2014 12:16:26 PM pbarthol.
BFF O1 10/21/14 JLL BLDG FLOOR FRAMING
10/21/14 AP October 21, 2014 9:55:08 AM jlierly.
October 21, 2014 3:59:29 PM jlierly.
BL9 01 11/04/14 JLL BLDG SHEARWALL
11/04/14 AP November 4, 2014 9:32:46 AM jlierly.
November 4, 2014 4:17:11 PM jlierly.
BAIR O1 12/01/14 JLL BLDG AIR SEAL
12/02/14 AP December 1, 2014 10:34:46 AM pbarthol.
Chris 775-5450
December 2, 2014 8:06:24 AM jlierly.
BL3 01 12/01/14 JLL BLDG FRAMING
12/02/14 AP December 1, 2014 10:34:19 AM pbarthol.
Chris 775-5450
December 2, 2014 8:06:24 AM jlierly.
BLI O1 12/03/14 JLL BLDG INSULATION
12/03/14 AP December 3, 2014 8:52:39 AM pbarthol.
Kurt 775-5450
December 3, 2014 3:28:57 PM jlierly.
BLDR O1 12/17/14 JLL BLDG DRYWALL IBWP
12/17/14 AP December 17, 2014 9:17:47 AM jlierly.
curt 775-5450
December 17, 2014 3:00:40 PM jlierly.
BL99 01 4/15/15 BLDG FINAL
April 15, 2015 10:30:16 AM jlierly.
curt 775-5450
------------------------------------------------------------------------------------------------
PERMIT: ME 00 MECHANICAL PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
ME99 01 4/15/15 3L MECHANICAL FINAL '
��``�� April 15, 2015 10:33:43 AM jlierly.
-------------------- '�- -----------------------
PERMIT: PL 00 PLUMBINGa TT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------ -------- -----
PL2 01 11/13/14 JLL PLUMBING ROUGH-IN
11/14/14 AP November 13, 2014 12:04:15 PM ,pbarthol.
----------------------------------- CONTINUED ONTO NEXT PAGE -----------------------------------
PREPARED 4/15/15, 10:33:44 INSPECTION TICKET PAGE 3
CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 4/15/15
------------------------------------------------------------------------------------------------
ADDRESS . : 1410 MORNING CT SUBDIV:
CONTRACTOR : PHONE
OWNER : GREEN CROW PROPERTIES INC PHONE
PARCEL 06-30-14-6-7-0420-0000-
APPL NUMBER: 14-00001109 RES NEW SFR
------------------------------------------------------------------------------------------------
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
--------------------------------------------------------------------------------------------
John 460-6902
November 14, 2014 4:21:58 PM jlierly.
PL6 01 12/05/14 JLL PLUMBING WATER SUPPLY
12/05/14 AP December 5, 2014 8:52:31 AM pbarthol.
Kurt 775-5450
December 5, 2014 4:04:15 PM jlierly.
PL99 01 4/15/15 ZLL PLUMBING FINAL
April 15, 2015 10:33:57 AM jlierly.
------------------------- - ---------- COMMENTS AND NOTES -------------------------------
CITY OF PORT ANGELES
s` DEPARTMENT OF COMMUNITY&ECONOMIC DEVELOPMENT-BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES,WA 98362.
Application Number . . . . . 14-00001109 Date 10/03/14 Q
Application pin number . . . 566378
Property Address . . . . . . .1410 MORNING CT
ASSESSOR PARCEL NUMBER: 06-30-14-6-7-0420-0000- REPORT SALES TAX
Application type description RES NEW SFR
Subdivision Name . . . . . . on your`State excise tax forum
Property Use . . . . . . . . to the City of Port Angeles
Property Zoning . . . . . . . RS9 RESDNTL SINGLE FAMILY
Application valuation . . . . 163196 (Location Code 0502)
----------------------------------------------------------------------------
Application desc
new sfr
----------------------------------------------------------------------------
Owner Contractor
------------------------
GREEN CROW PROPERTIES INC OWNER
PO BOX 2439
PORT ANGELES WA 983620312
------------------------------------------ ------------- --------------
Permit . . . . BUILDING -
, PERMIT RESIDENTIAL
Additional desc NEW SFR
Permit Fee . . . . 1378.65 Plan Check Fee 896.12 ^
Issue Date . . . . 10/03/14 Valuation . . . . 163196 a
Expiration Date 4/01/15 �y
Qty Unit Charge Per Extension
BASE FEE 1020.25
64.00 5.6000 THOU BL-100,001-500K (5.60 PER K) 358.40
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL PERMIT
Additional desc . . SFR MECHANICAL
Permit Fee . . . . 189.10 Plan Check Fee .00
Issue Date . . . . 10/03/14 Valuation . . . . 0
Expiration Date . . 4/01/15
Qty Unit Charge Per Extension
BASE FEE 50.00
1.00 14.8000 EA ME-FURN/HP/FAU < OR = 5 TON 14.80
4.00 7.2500 EA ME-VENT FAN (SINGLE DUCT) 29.00
2.00 10.6500 EA ME-HOOD/DUCT-MECH. EXHAUST 21.30
5.00 14.8000 EA ME-HEATER(SUSP/WALL/FLOOR-MTD) 74.00
----------------------------------------------------------------------------
Permit . . . . . PLUMBING PERMIT
Additional desc . SFR PLUMBING
Permit Fee . . . . 170.00 Plan Check Fee .00
Issue Date . . 10/03/14 Valuation . . . . 0
Expiration Date . . 4/01/15
Qty Unit Charge Per Extension
BASE FEE 50.00
9.00 7.0000 EA PL-PLUMBING TRAP 63.00
1.00 7.0000 EA PL-WATER LINE 7.00
4.00 7.0000 EA PL-DRAIN VENT PIPING 28.00
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction. (^
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
Tforms/Building Division/Building Permit
BUILDING PERMIT INSPECTION RECORD
PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS—
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-In
Water Line Meter to Bldg)
Gas Line
Back Flow/Water FINAL Date Accepted b
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall Interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pum /Furnace/FAU/Ducts
Rough-In
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts FINAL Date Accepted b
MANUFACTURED HOMES:
Footing/Slab
Blocking 8 Hold Downs
Skirting
PLANNING DEPT. Separate Permit#s SEPA:
Parkin /Lighting ESA:
Landscaping SHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction-R.W. PW I Engineering 417-4831
Fire 417-4653
Planning 417-4750
Building 417-4815
T:Forms/Building Division/Building Permit
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY& ECONOMIC DEVELOPMENT- BUILDING DIVISION
09f
321 EAST 5TH STREET, PORT ANGELES, WA 98362
Page 2
Application Number . . . . . 14-00001109 Date 10/03/14
Application pin number 566378
REPORT SALES TAX
Qty Unit Charge Per Extension
1.00 15.0000 EA PL-SEWER LINE 15.00 on your state excise tax form
1.00 7.0000 EA PL-WATER HEATER 7.00 to the City of Port Angeles
---------------------------------------------------------------
Special Notes and Comments (Location Code 0502)
September 19, 2014 3:11:12 PM tamiot.
ELECTRICAL PERMIT WILL BE REQUIRED.
ELECTRICAL SERVICE SHALL BE UNDERGROUND TO THE EXISTING
PEDESTAL IN THE SOUTHWEST CORNER.
Address numbers shall be plainly visible from the street.
Address numbers shall be a minimum of six inches high and be
of contrasting color from the background.
September 17, 2014 4:28:32 PM sroberds.
The proposal will result in a new sfr in the RS-9 for total
lot cov of 23W and site cov of 28%. No land use issues
anticipated.
Ditches & 8" culverts will be installed to City Stanards.
See Public Works Engineering for Standards.
1. Establishing Construction Access.
2. Install sediment controls BMPs.
3. Stabilize exposed soils.
4. Protect slopes from erosion..
5. Protect drain inlets.
6. Control pollutants including but not limited to spills,
concrete wash out, exposed aggregate processes, concrete
grinding and saw cut waste water.
7. Maintain temporary and permanent erosion control BMPS
during project.
Consider applying for the City Green Infrastructure Rebate
of up to $750.00 towards the materials to install rain
garden to control roof and driveway runoff. Also rebates
available for downspout disconnections.Contact Jonathan
Boehme at 360 417-4811
All construction work within the City right of way requires
a separate Right of Way Construction application to be
completed by the contractor and approved by Public Works
Engineering prior to the start of work. A pedestrian or
traffic control plan is to be submitted for approval with
the application as necessary.
Trench safety per applicable laws. Temp erosion control and
surface restoration responsibility of applicant. Contact
City inspector prior to start of work @ 360 417-4831. No
attachment to sanitary sewer of stormwater roof leaders,
foundation drains, yard drains, or any other CSO
contribution is allowed.
Sanitary sewer connection inspection is required by
Public Works prior to back fill of ditch. 24 hour advance
notice is required. Public works Inspection request line
417-4831
Construct driveway to City Standards. Concrete with exposed
aggregate or other non-standard finishes(including colors or
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
BUILDING PERMIT INSPECTION RECORD
-- PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rou h-In
Water Line Meter to Bldg)
Gas Line
Back Flow/Water FINAL Date Accepted b
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall Interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pum /Furnace/FAU/Ducts
Rough-in
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts FINAL Date Accepted b
MANUFACTURED HOMES:
Footing/Slab
Blocking&Hold Downs
Skirting
PLANNING DEPT. Separate Permit#s SEPA:
Parkin /Lighting ESA:
Landscaping SHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction-R.W. PW I Engineering 417-4831
Fire 417-4653
Planning 417-4750
Building 417-4815
T:Forms/Building Division/Building Permit
CITY OF PORT ANGELES
(IQ7
DEPARTMENT OF COMMUNITY&ECONOMIC DEVELOPMENT- BUILDING DIVISION
te 321 EAST 5TH STREET, PORT ANGELES,WA 98362
Page 3
Application Number . . . . . 14-00001109 Date 10/03/14
Application pin number . . . 566378
---------------------------------------------------------------------------- REPORT SALES TAX
Special Notes and Comments on our state excise tax form
dyes)are not allowed in the City road right of way. Broom }�
finish only. An inspection by Public Works Engineering is to the City of Port Angeles
required prior to pouring concrete. Public Works inspection
request line 417-4831 (Location Code 0502)
Other Fees . . . . . . . . . RES UNDERGRND SERVICE FEE 770.00
SEWER SYSTEM DELV CHARGE 2260.00
STATE SURCHARGE 4.50
PW WATER SYSTEM USE FEE 2260.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 1737.75 1737.75 .00 .00
Plan Check Total 896.12 896.12 .00 .00
Other Fee Total 5294.50 5294.50 .00 .00
Grand Total 7928.31 7928.37 .00 .00
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced,or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
BUILDING PERMIT INSPECTION RECORD
PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS—
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-In
Water Line Meter to Bldg)
Gas Line
Back Flow/Water FINAL Date Accepted b
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall Interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pum /Fumace/FAU/Ducts
Rough-in
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts FINAL Date Accepted b
MANUFACTURED HOMES:
Footing/Slab
Blocking&Hold Downs
Skirting
PLANNING DEPT. Separate Permit#s SEPA:
Parkin /Lighting ESA:
Landscaping SHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction-R.W. PW /Engineering 417-4831
Fire 417-4653
Planning 417-4750
Building 417-4815
T:Forms/Building Division/Building Permit
CITY OF PORT ANGELES
,'1L® PUBLIC WORKS &UTILITIES
321 EAST 5TH STREET, PORT ANGELES,WA 98362
Application Number . . . . . 14-00001109 Date 10/03/14
Application pin number . . . 566378
Property Address . . . . . . 1410 MORNING CT
ASSESSOR PARCEL NUMBER: 06-30-14-6-7-0420-0000- REPORT SALES TAX
Application type description RES NEW SFR
Subdivision Name . . . . . . on your state excise tax form
Property Use . . . . . . . . to the City of Port Angeles
Property Zoning . . . . . . . RS9 RESDNTL SINGLE FAMILY
Application valuation . . . . 163196 (Location Code 0502)
----------------------------------------------------------------------------
Application desc
new sfr
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
GREEN CROW PROPERTIES INC OWNER
PO BOX 2439
PORT ANGELES WA 983620312
----------------------------------------------------------------------------
Permit . . . . . . DRIVEWAY INSTALLATION
Additional desc .
Permit Fee . . . . 180.00 Plan Check Fee .00
Issue Date . . . . 10/03/14 Valuation . . . . 0
Expiration Date 4/01/15
Qty Unit Charge Per Extension
BASE FEE 180.00
----------------------------------------------------------------------------
Permit . . . . . . PUBLIC WORKS RES WATER SERV
Additional desc 5/8" DROP IN WATER METER
Permit Fee 420.00 Plan Check Fee .00
Issue Date . . . . 10/03/14 Valuation . . . . 163196
Expiration Date . . 4/01/15
Qty Unit Charge Per Extension
1.00 420.0000 EA PW WATER METER DROP IN 420.00
----------------------------------------------------------------------------
Permit . . . . . . SANITARY SEWER HOOK UP
Additional desc . .
Permit Fee . . . . 150.00 Plan Check Fee .00
Issue Date . . . . 10/03/14 Valuation . . . . 163196
Expiration Date . . 4/01/15
Qty Unit Charge Per Extension
1.00 150.0000 EA SAN SEWER HOOKUP 150.00
----------------------------------------------------------------------------
Special Notes and Comments
September 19, 2014 3:11:12 PM tamiot.
ELECTRICAL PERMIT WILL BE REQUIRED.
ELECTRICAL SERVICE SHALL BE UNDERGROUND TO THE EXISTING
PEDESTAL IN THE SOUTHWEST CORNER.
Address numbers shall be plainly visible from the street.
Address numbers shall be a minimum of six inches high and be
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements.This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work as commenced,or if required inspections have not been requested within 180 days from the last
inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of
laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Signature of Contractor or Authorized Agent Date Signature of Owner(if owner is builder) Date
T:Fortns/Building Division/Public Works Permit
PERMIT INSPECTION RECORD
CALL 417-4831 FOR UTILITY INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVE,
INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION.
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE
INSPECTION TYPE DATE ACCEPTED COMMENTS
YES NO
PW UTILITIES (Engineering Division)
WATERLINE/METER
SEWER CONNECTION
SANITARY
STORM
SITE DRAINAGE
SITE EROSION CONTROL
PARKING
SIDEWALK
CURB&GUTTER
DRIVEWAY APPROACH
BACK-FLOW DEVICE
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED
YES I NO
CONSTRUCTION R.W./PW/ CONSTRUCTION-R.W.
ENGINEERING 417-4807 PW/ENGINEERING
FIRE 4174653 FIRE DEPT.
PLANNING DEPT. 417-4750 PLANNING DEPT.
BUILDING 447- BUILDING
4815
T:Forms/Building Division/Public Works Permit
,ORT
""° CITY OF PORT ANGELES
ti+��`��w
��� PUBLIC WORKS &UTILITIES
` 321 EAST 5TH STREET, PORT ANGELES,WA 98362
Page 2
Application Number . . . . . 14-00001109 Date 10/03/14
Application pin number . . . 566378
---------------- ----------------------------- REPORT SALES TAX
Special Notes and Comments our state excise tax form
of contrasting color from the background. 011 y
September 17, 2014 4:28:32 PM sroberds. to the City of Port Angeles
The proposal will result in a new sfr in the RS-9 for total (Location Code 0502)
lot cov of 23t and site cov of 28%. No land use issues
anticipated.
Ditches & 8" culverts will be installed to City Stanards.
See Public Works Engineering for Standards.
1. Establishing Construction Access.
2. Install sediment controls BMPs.
3. Stabilize exposed soils.
4. Protect slopes from erosion.
5. Protect drain inlets.
6. Control pollutants including but not limited to spills,
concrete wash out, exposed aggregate processes, concrete
grinding and saw cut waste water.
7. Maintain temporary and permanent erosion control BMPS
during project.
Consider applying for the City Green Infrastructure Rebate
of up to $750.00 towards the materials to install rain
garden to control roof and driveway runoff. Also rebates
available for downspout disconnections.Contact Jonathan
Boehme at 360 417-4811
All construction work within the City right of way requires
a separate Right of Way Construction application to be
completed by the contractor and approved by Public Works
Engineering prior to the start of work. A pedestrian or
traffic control plan is to be submitted for approval with
the application as necessary.
Trench safety per applicable laws. Temp erosion control and
surface restoration responsibility of applicant. Contact
City inspector prior to start of work @ 360 417-4831. No
attachment to sanitary sewer of stormwater roof leaders,
foundation drains, yard drains, or any other CSO
contribution is allowed.
Sanitary sewer connection inspection is required by
Public Works prior to back fill of ditch. 24 hour advance
notice is required. Public Works Inspection request line
417-4831
Construct driveway to City Standards. Concrete with exposed
aggregate or other non-standard finishes(including colors or
dyes)are not allowed in the City road right of way. Broom
finish only. An inspection by Public Works Engineering is
required prior to pouring concrete. Public Works inspection
request line 417-4831
----------------------------------------------------------------------------
Other Fees . . . . . . . . . RES UNDERGRND SERVICE FEE 770.00
SEWER SYSTEM DELV CHARGE 2260.00
STATE SURCHARGE 4.50
PW WATER SYSTEM USE FEE 2260.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work as commenced,or if required inspections have not been requested within 180 days from the last
inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of
laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Signature of Contractor or Authorized Agent Date Signature of Owner(if owner is builder) Date
T:Forms/Building Division/Public Works Permit
PERMIT INSPECTION RECORD
CALL 417-4831 FOR UTILITY INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVE,
INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INA CONSPICUOUS LOCATION.
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE
INSPECTION TYPE DATE ACCEPTED COMMENTS
YES NO
PW UTILITIES (Engineering Division)
WATERLINE/METER
SEWER CONNECTION
SANITARY
STORM
SITE DRAINAGE
SITE EROSION CONTROL
PARKING
SIDEWALK
CURB&GUTTER
DRIVEWAY APPROACH
BACK-FLOW DEVICE
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED
YES I NO
CONSTRUCTION R.W./PW/ CONSTRUCTION-R.W.
ENGINEERING 417-4807 PW/ENGINEERING
FIRE 4174653 FIRE DEPT.
PLANNING DEPT. 417-4750 PLANNING DEPT.
BUILDING 417_ BUILDING
4815
T:Forms/Building Division/Public Works Permit
°FP°RTS° CITY OF PORT ANGELES
+ PUBLIC WORKS &UTILITIES
321 EAST 5TH STREET, PORT ANGELES, WA 98362
Page 3
Application Number . . . . . 14-00001109 Date 10/03/14
Application pin number . . . 566378
----------------- ---------- ---------- ---------- ---------- REPORT SALES TAX
Permit Fee Total 750.00 750.00 .00 .00
Plan Check Total .00 .00 .00 .00 on your state excise tax form
Other Fee Total 5294.50 5294.50 .00 .00 to the City of Port Angeles
Grand Total 6044.50 6044.50 .00 .00
(Location Code 0502)
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work as commenced,or if required inspections have not been requested within 180 days from the last
inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of
laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Signature of Contractor or Authorized Agent Date Signature of Owner(if owner is builder) Date
T:Forms/Building Division/Public Works Permit
PERMIT INSPECTION RECORD
CALL 417-4831 FOR UTILITY INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO Coiik,
INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INA CONSPICUOUS LOCATION.
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE
INSPECTION TYPE DATE ACCEPTED COMMENTS
YES =NO
PW UTILITIES (Engineering Division)
WATERLINE/METER
SEWER CONNECTION
SANITARY
STORM
SITE DRAINAGE
SITE EROSION CONTROL
PARKING
SIDEWALK
CURB&GUTTER
DRIVEWAY APPROACH
BACK-FLOW DEVICE
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED
YES NO
CONSTRUCTION R.W./PW/ CONSTRUCTION-R.W.
ENGINEERING 4174807 PW/ENGINEERING
FIRE 4174653 FIRE DEPT.
PLANNING DEPT. 4174750 PLANNING DEPT.
BUILDING 417- BUILDING
4815
T:Forms/Building Division/Public Works Permit
THEV T �` GET Cc For City Use
TY OF .Lv l7 ��
i ;{ Permit# /
W A S H I N G T O N , U . S.
I Date Received: `'r
321 E 5th Street Date Approved
Port Angeles,WA 9836 '
P:360-417-4817 F:360-417-4711
Email:permits0cityofoa.us BUILDING PERMIT APP ICATION
Project Address: i*o Morning Court, Port Angeles, 98362
Phone: (36o) 4117-3669
Primary Contact: Bruce Emery Email: biruce@greencrow.com
Name Phone(36o)41.7-3669
Green Crow properties,Inc.
Property Mailing Address Email bruce@greencrow.com
Owner P.O.Box 2439
City State WA Zip 98362
Port Angeles
Name Phone (same)
Green Crow Construction LLC
Contractor Address Email (same)
(same)
Information city State Zip
Contractor License#GREENCC933CZ Exp.Date: 3/7/2015
Legal Description: Zoning: Tax Parcel# Project Value: (materials and labor)
Lot 42, Riedell II, Phase 3 RS9 o63014-670420 $163,196
Residential X Commercial ❑ Industrial ❑ Public ❑
Permit Demolition ❑ Fire ❑ Repair ❑ Reroof(tear off/lay over) ❑
Classification For the following.fill out both pages of permit application:
(check New Construction X Exterior Remodel ❑ Addition ❑ Tenant Improvement ❑
appropriate)
Mechanical ❑ Plumbing ❑ Other ❑
Will a fire sprinkler system be installed Irrigation System? Proposed Bathrooms Proposed Bedrooms
or modified? Yes El No X Yes ❑ No X 2 2
Project Description
Construction of a single-family
residence.
Is project in a Flood Zone: Yes ❑ No x Flood Zone Type:
If in a Flood Zone, what is the value of the structure before proposed improvement? $
I have read and completed the application and know it to be true and correct. I am authorized to apply for
this permit and understand that it is my responsibility to determine what permits are required and to
obtain permits prior to work. I understand that plan review fees are not refundable after review has
occurred. I understand that I will forfeit review fees if I withdraw the application before the permit is
issued. I understand that if the permit is not picked up/issued within 18o days of submittal,the application
will be considered abandoned and the fees will be forfeited.
og/16/14 Bruce Emery
Date Print Name Signature
Residential Structures
For Office Use
Area Description(SQ FT) Existing Proposed $$value
Basement N/A
First Floor 1,7.12 14.5,520
Second Floor N/A
Covered Deck/Porch/Entry 78 936
Deck(over 30"or 2nd floor) N/A
Garage 558 16,74o
Carport N/A
Other(describe) N/A
Area Totals 2,348 163,196
Commercial Structures
Proposed For Office Use
Area Descriptions(SQ FT) Existing Proposed ss Value
Existing Structure(s)
Proposed Addition
Tenant Improvement?
Other work(describe)
Site Area Totals
Lot/Site Coverage Calculations
Lot Size(sq ft) Lot Coverage (sq ft) %Lot Coverage(Total lot coverage-lot size)
1OP341 2,s48 2
Site Coverage(Sq Ft of all impervious) %of Site Coverage(total site coverage_lot size)
2,898 28
Mechanical Fixtures
Indicate how many of each type of fixture to be installed or relocated as part of this project.
Air Handler: Size: # Haz/Non-Haz Piping: Outlets:
Appliance Exhaust Fan: # Heater(Suspended,Floor,Recessed wall): #
2 5
Boiler/Compressor Size: # Heating/Cooling appliance #
repair/alteration
Evaporative Cooler(attached,not # Pellet Stove/Wood-burning/Gas #
portable): Fireplace/ as Stove/Gas Cook Stove/Misc.
Fuel Gas Piping: #of Outlets: Ventilation Fan,single duct: #
4
Furnace eat Pu Size: # Ventilation System: #
Forced Air nt : ctlss 1
Plumbing Fixtures
Indicate how many of each type of fixture to be installed or relocated
Plumbing Traps #9 Fuel gas piping #of Outlets:
Water Heater #1 Medical gas piping #of Outlets:
Water Line #1 Plumbing Vent piping #
n
Sewer Line #1 Industrial waste pretreatment
interceptor Grease Trap) Size
Other(describe):
T:\BUILDING\APPLICATION FORMS\Current BP Application\Building Permit 4-17-13.docx
/ 'a I PROVIDE TW(
I BETWEEN UN1
/ r MASONRY, OI
/ IJ
/ r
/
�I
� I I
r HOUSE
GARAGE i
r
r
\ / +GONG F'ORGw � -
A9�+Au
DRIVEWA7 /
Ilk� / � �
Prescriptive Energy Code Compliance for All Climate Zones in Washington
Project Information Contact Information
IVIO ItCR- cure i fCve
This project will use the requirements of the Prescriptive Path below and incorporate the
the minimum values listed.In addition,based on the size of the structure,the appropriate
number of additional credits are checked as chosen by the permit applicant.
Authorized Representative Date
R-Valuea U-Factora
Fenestration U-Factorb n/a 0.30
Skylight Ll-Factor n/a 0.50
Glazed Fenestration SHGCb,e n/a n/a
Ceiling 49 0.026
Wood Frame Wall9.k,l 21 int 0.056
Mass Wall R-Value' 21/21h 0.056
Floor 309 0.029
Below Grade Wall,k 10/15/21 int+TB 0.042
Slab R-Value&Depth 10,2 ft n/a
"Table R402.1.1 and Table R402.1.3 Footnotes included on Page 2.
Each dwelling unit in one and two-family dwellings and townhouses,as defined in Section 101.2 of the
International Residential Code shall comply with sufficient options from Table R406.2 so as to achieve the
following minimum number of credits:
❑1.Small Dwelling Unit: 0.5 points
Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration
rea. Additions to existing building that are less than 750 square feet of heated floor area.
Medium Dwelling Unit: 1.5 points
All dwelling units that are not included in#1 or#3, including additions over 750 square feet.
F]3. Large Dwelling Unit: 2.5 points
Dwelling units exceeding 5000 square feet of conditioned floor area.
Table R406.2 Summary
Option Description Credit(s)
la Efficient Building Envelope 1 a 0.5
lb Efficient Building Envelope 1 b 1.0 El
1c Efficient Building Envelope 1c 2.0 El
2a Air Leakage Control and Efficient Ventilation 2a 0.5 1:1
2b Air Leakage Control and Efficient Ventilation 2b 1.0 E]
2c Air Leakage Control and Efficient Ventilation 2c 1.5 F1
3a High Efficiency HVAC 3a 0.5
3b High Efficiency HVAC 3b 1.0
3c High Efficiency HVAC 3c 2.0
3d High Efficiency HVAC 3d 1.0 1.0
4 High Efficiency HVAC Distribution System 1.0
5a Efficient Water Heating 0.5 Q 0.5
5b Efficient Water Heating 1.5
6 Renewable Electric Energy 0.5 "1200 kwh 0.0
Total Credits 1.50
*Please refer to Table R406.2 for complete option descriptions
http://www.energy.wsu.edu/Documents/2012`/`2ORes%2OEnergy.pdf
PORTgNCF`�3 Stormwater Green Wrasttructure Rebate Program 2024
® Rain Garden and Residential Downspout Disconnection
a■�� Rebate Application
°oC
Name:
When it rains,runoff flows from our roofs,yards and driveways,carrying oil,fertilizers,
pesticides,and other pollutants into our environment. The City of Port Angeles wants to
assure that does not happen. The Stormwater Green Infrastructure Rebate Program's aim is
to reduce the amount of pollutants that enter the environment.
Rain Gardens
The City of Port Angeles is providing financial assistance to residents and businesses building
rain gardens at their home or place of business. Approved applicants may receive a rebate of
up to$750 for the purchase of materials,such as plants,compost,sand, mulch and rock.
Residential Downspout Disconnections
The City of Port Angeles is providing financial assistance to residents disconnecting
downspouts from the Combined Sewer or Stormwater System. Approved applicants may
receive a rebate of$25 per downspout draining to the Combined Sewer,$150 maximum,or
$12.50 per downspout draining to the Stormwater System,$75 maximum.
The stormwater from disconnected downspouts must be directed to onsite controls such as a
drywell, rain garden,rain barrels,dispersion,or other approved method.
Program Guidelines:
• Rain gardens and downspout disconnections must be located inside City limits.
• Applicants must be approved prior to commencement of construction.
• Rain Garden Rebate and Residential Downspout Disconnection Rebates may be
combined, but limit one rebate of each type per household or business.
• A minimum of 400 square feet of impervious surface area,such as roofs,driveways,or
patios must drain to proposed rain garden to be eligible.
Applications will be accepted from January 1,2014,through November 30,2014,or until
available funding is depleted,whichever comes sooner. All work must be completed and
Rebate Form submitted by December 10,2014. Applicants will be notified regarding the
status of approval or denial of their applications within three weeks of their application
submittal. Applicants denied rebates may revise and resubmit their applications for
reconsideration if they adequately address all prior comments. Suggested rain garden design
details may be found on the City website: http://www.citvofpa.us/Stormwater.htm
For more information contact the City of Port Angeles at 360-417-4830
Or to schedule a free site assessment contact Master Gardeners at 360-565-2679
Stormwater Green Wrastlructurre Rebate Appflcant Wormation
(required information)
Name:
Site Location Address:
Contact(Please check the best method to contact you)
o Mailing Address:
o Phone Number and best time to call:
o Email:
Applying for:
F Rain Garden Rebate
❑ Downspout Disconnection Rebate
Project Details:
What are your project goals?
Please attach the following items to your application for Rain Garden Rebate:
o Photos of the area BEFORE installation
• Green Rebate Worksheet(for free site assessment contact: Master Gardeners at 360-565-2679)
o Infiltration Test Checklist
• Sketch of the design and planting layout
Please attach the following items to your application for Downspout Disconnection Rebate:
• Photos of the area BEFORE installation
• Green Rebate Worksheet
• Sketch of where the downspouts currently drain
• Sketch of the design for onsite stormwater controls
• Number of downspouts to disconnect:
➢ Following construction,submit rebate form with original receipts no later than December 10,2014
in order for the rebate to be processed.
➢ Call(360)417-4830 to schedule a FINAL inspection. Rebates will not be disbursed without a final
inspection.
[12/3/2013] Page 2/7
Certification
By submitting this application I certify that I am the legal property owner as shown in the deed or I
have obtained permission from the property owner to change the landscaping. I agree to perform
routine maintenance on the rain garden or other stormwater controls,and keep the installed system in
good working order for a minimum of two years. I grant the City permission to conduct site inspections
of my stormwater system at times that are mutually acceptable to me and the City.
I acknowledge that the City of Port Angeles provides examples of rain gardens and stormwater control
designs. I understand that the City did not design,install,or oversee the installation or design of my
rain garden or stormwater control installed on my property. 1 am solely responsible for the design,
installation,and functioning of the rain garden or stormwater control installed on my property. The
City is not responsbilie for any loss,injury,flooding,or other damage that may occur or result from the
rain garden or storm water control installed on my property or the downspout(s)disconnected on my
property. By accepting the rebate, I hereby waive and release the City from any claim,cause of action,
or liability from any loss,injury,flooding,or other damage whatsoever arising or resulting from the
design,installation,and function of the rain garden or stormwater control installed on my property.
As a condition of this application and receiving City funds, I give the City permission to release the
location of my rain garden,and I agree that my rain garden may be photographed by the City for
documentation and promotion purposes.
X
Signature Date
Send complete applications by one of the following methods:
Mail to: City of Port Angeles Email:stormwater@cityofpa.us
c/o Stormwater Rebate Program
321 E Fifth Street—P.O. Box 1150
Port Angeles,WA 98362
For City Use: Date Received: Approval:
age
Green Rebate Worksheet - Feasibility
Date
Referred by
Property Owner:
Address:
Public Sewer: Private drainfield: Type of onsite sewage system:
Tax Parcel Number Watershed(if known)
DESIGN CONSIDERATIONS-LOCATION
Ideal rain garden or infiltration sites are fairly flat downhill from runoff source,and well drained. See pages 6-7 of the Rain Garden Handbook.
❑ Green infrastructure site>10 ft downslope or>50 ft upslope of drainfield
❑ Check for buried utilities at site(call sss to have utilities located)
❑ Slope<15%(rise of slope/length of slope)
❑ Site>10 ft from buildings
❑ Site downhill of runoff source
❑ Groundwater>1ft below bottom of green infrastructure
❑ Soil drainage>0.25 in/hr(see Infiltration Test Checklist)
Percolation Tests: Hole One Trial 1 Trial 2 Trial 3
Hole Two Trial 1 Trial 2 Trial 3
❑ Safe overflow path (where will water drain to if it overflows rain garden?)
DESIGN CONSIDERATIONS—DRAINAGE,SIZE AND OUTFLOW
❑ Measure how much area is draining to the Rain Garden or other stormwater control (pg 10 of the Handbook)
square feet of roof area and square feet of yard or driveway will drain to the rain garden for
a total are of square feet
❑ Measure how much area is available for the rain garden (pg ii of the Handbook): square feet
❑ Options for inflow to garden (e.g.buried pipe,swale,overland flow)
❑ Options for outflow from garden (e.g.storm drain,disperse to open landscape)
CONCLUSION—Is site suitable for green stormwater infrastructure?
[12/3/2013] Page 4/7
T
Green Rebate Worksheet— Design
Budget
Design Costs: Who will design the rain garden? ❑ Self ❑ Consultant $
Labor Costs: Who will install the rain garden? ❑ Self ❑ Contractor $
Material Costs:
Materials(Plants,soil) Quantity Source (ie Nursery) Area Required(sq-ft) Cost
Total Estimated Green Infrastructure Cost: $
Number of disconnected downspouts:
Disconnected from Sanitary Sewer at$25 each Number : $
Disconnected from Stormwater System at$12.50 each Number: $
What is the estimated rebate amount requested? $
(Maximum rain garden materials rebate is$750.)
(Maximum disconnection rebate is$150.)
[12/3/2013] Page 5/7
t
Perform an Infiltration Test Checklist
As port of your Green Rebate Worksheet-Feu.,-
How
euvHow water flows through soil plays a significant role in how large to build a rain garden. A glacial till or
clay subsoil can act as a seal underneath the topsoil. If there is enough rain, the topsoil will become
saturated and there will be no place for the water to go regardless of the characteristics of the topsoil.
To properly size your rain garden or other stormwater control, perform the following infiltration test:
Test:
1) Dig a hole 24 inches deep and at least 10 inches
across. Add a stake with a ruler attached to it.
2) Fill with a hose to a depth of 12 inches, and let drain
completely. -
axe •-,
3) Repeat fill to 12-inch depth and drain a second time. "`
'" r a ,
4ii
This may take overnight. * _ y4 1
4) On the third fill to 12-inch depth:
Measure the water height every hour. Note your results in the table included in this form.
-Continue until the rate of fall stabilizes. (Same amount of fall for 2-3 hours)
- Use that as the infiltration rate. (inches/hour)
If you find any of the following conditions during your test
• You hit hard pan
• Your test hole does not drain at least .25"per hour; OR
• Your test hole fills with water
Do not attempt to install a rain garden or other infiltration system!
[12/3/2013] Page 6/7
e
r
Results Table (Fill this out during your third t rll)
Percolation
Infiltration Rate
Test Hole# Elapsed Water depth
(depth of fall in
(Multiple test Time measurement Notes/Comments
holes are (hours) (in inches) inches/time in
hours)
recommended)
1 Zero 12 inches Initial fill
1
You must sign the statement below and return this document with your
application.
I certify that I have followed the procedures outlined in this document to determine my rain garden or
stormwater control sizing. I have chosen to size my rain garden or stormwater control in accordance
with these results. I understand that rain gardens are sized for moderate rain events and that
regardless of infiltration ability of my soil that my rain garden must have a clear and safe overflow.
Test performed by:
• Homeowner Print Name
Signature Date
• Contractor Print Name
Signature Date
[12/3/2013] Page 7/7
ag
z -
1
r
• ' -��' �
Porter Pa St
V
w
Q'j
c
""Ort7it7g C,
y+M
a � a
a
o
a
N
cn
w a
rn
f '
i.
N -. S.`"'""„"—^ ::, ��._i w ,cii �,� :, � #���'�Y'rL•.-f'�y-..�y�.�r �
,A - } - h 4y, Vie? '•'�" .�� ��'{ .fvW .� ��F r"•�. y _-
_ c
a � •. n f a� cn
r �
w a
w-.
a
� P
,
aM �r• � .�� .:
't'„� � w
n
N
.
t '
! _ BRACED PAWL ALTERNATE BRACED WALL
Q RB SHEAR WALL PANELS ® 8F8 ALTERNATE BRACED PANELS
AO'MN
anlo�nme A
:9/3rT er'TTaIGTTwAL FIBERBOARD eHEATHTNG
oC
,M;,5,TRJCMRAL ni uFIBERBOARD"AnWew PaeiEr ERe
n'eEAtHNG-I n•LONGxon•Dw
i -- Pf$TEtEiRB 19/!1.BW+ITHNG-13/4•LQYs X On'DIA
LONGO%O�DIA NAIL EDGES AT 3'CN C NrTe' AND RELD AT 6•CN
�` µplL Ep�E9 C�C�7� ... CENTER FOR BOTH TRIG TM
CENTER
FOR
9NEAT9G TTPE6 IELD AT b'CN
GB Q M BEDRXM ® GB e1EAR WALL PANELS
S.r... 4e•MN
i O / DUN
6 yAp��I BOAFO IUEETNG
WO.
k`"4 �•. M BATH . - MUM*
OM GAGE 1 3/e'LONG IW64'HEAD,�DpOpWLp1DIA�I�ETER,
x �� ___ o••o Ts• I Q - I V4• �A61 NEADOR
G1M BOARD IL,ODB6'bN'IE7ER I&9'LGNG.
tl8 1611 LKTL7 MI J II — – ---.._... 1W HEAD,
/ Q I .- - - DMW10R LOCATM
V3'GLAVANIZEp ROLFNG NAIL eTAFLE GALVANIZED,
I I' ab B II V3'LRYaIV4 eC]EYI9,TTPEWORa
EER EO9RAt 14 b�FEAT�PIGRTI FE9 MD AT V ON
T I CLOW II I KITCHEN I II
A� 1 �I' '�7o-�'r W'TW S l rn p o,l•./ L-ST/a D g
O BaT�I 36" -----------1-a
6DO 1.» 6DO .
LIVMG
Tae
g BEDRXM cl LAINM
O rAAcC.RO
3=04
q
�--�
W
DEN
_
rATIIC, 01Q -
L�J SS I
' I Y10 ]ORO I _. ... ••
a
_�__- 1
it I i
I I I
i I I I
I
w.raTo _.
I
FLOOR PLAN
NORTH
C
RE1—_—
R
GREEN CROW
LOT 42
BRACE WALLS
Option One — SFB Brace Panels
Minimum length per table R602.10.3(1)
Braced wall line spacing: 30'-0"
Methods — SFB: 8'-6"
Wind adjustment factor: 1.5
Table R602.10.3(2)
Minimum length = 8'-6" X 1.5 = 12'-9"
Option Two —GB Brace Panels
Minimum length per table R602.10.3(1)
Braced wall line spacing: 30'-0"
Methods— SFB: 14'-6"
Wind adjustment factor: 1.5
Table R602.10.3(2)
Minimum length = 14'-6" X 1.5 = 21'-9"
Note:
R602.10.2.3 Minimum number of braced wall panels:
< 16'-0" wall line requires one (1) 48" panel.
> 16'-0" wall line requires two (2) 48" panels.
Maximum spacing between panels in a wall line is 30'-0". �iext
}'
;Zs vtl
Residence
Wall 'A':
SFB Alternate Braced Panels -
Providing total length of 5'-8" of alternate braced panels.
Wall 'B':
GB Brace Panels —
Minimum 21'-9" length required.
30'-0" maximum spacing —
Providing total length of 22'-6" of brace panels.
Wall 'C':
GB Brace Panels —
Minimum 12'-9" length required.
30'-0" maximum spacing —
Providing total length of 22'-0" of brace panels.
Wall 'D':
SFB Brace Panels —
Minimum 12'-9" length required.
30'-0" maximum spacing —
Providing total length of 13'-0" of brace panels.
Wall `1':
SFB Brace Panels —
Minimum 12'-9" length required.
30'-0" maximum spacing —
Providing total length of 16'-0" of brace panels.
Wall '2':
GB Brace Panels —
Minimum 21'-9" length required.
30'-0" maximum spacing —
Providing total length of 22'-0" of brace panels.
II
Wall '3':
SFB Brace Panels —
Minimum 12'-9" length required.
30'-0" maximum spacing —
Providing total length of 15'-6" of brace panels.
BRACED PANEL ALTERNATE BRACED WALL
SF5$HEAR WAIL PANELS SFS ALTERNATE BRACED PANELS
1 L WK 00 "2 IHl 48 MM 1/2
WI; 25/32"STRIGTURAL FIBERBOARD SHEATHING
i In"OR 15/32"STRICTURAL FIBERBOARD SHEATHING I WITH 51UD&A7
Y Y S4 STUDS AT Ib"O.G.
FASTENERS
25/31"SHEATHING-13/4"LONG X DI DIA IR"SHEATHING•11/211 LONG k 0.11"DIA-
FA
IA
¢tet. FA 25/32"SHEATHING-13/4'LONG X 0.12"DIA.
IR SHEATHING-I I?2 LONG X 0.12 DIA I ON�
An$14f �' w NAIL EDGES AT 3 ON CEENNTER AND FIELD AT 6 ON
CENTER ORS BOAT TH$HEATINWGRT�S FIELD AT 6"ON
f CENTER FOR BOTH SNEATINCs TYPES
(�
M.BEDROOM GB SHEAR WALL PANELS
48"MM.
O \ I/1"THICK GYPSUM BOARD SHEETING
1 z j WITH STUDS AT 16"O.G.
O M.BATH !\ I FASTENERS
I
INTERIOR LOC
3GRER3OCLIOONNgG 1�9/6�4"HEAD:�`opAp9L8"DtAI'IETER,
G r--- o o pl I I /AB6�'DI 6METEU 15/S"LOs Ib/64"HEE D
I I I� - GYPSUM BOARD NAIL,OD86"DIAMETER,15/S"LONG, ;
Gap 7L68 ABMT ABV -J 9/32 HEAD. ,
t 1 EXTERIOR'LOCATION$
I I/2"GLAVANIZEP ROOFING NAIL;STAPLE GALVANIZED,
11/1^LONG,1 V411 SCREW,TYPE W OR$,
/ NAIL EDGES AT 1"ON CENTER AND FIELD AT 1"ON
03ET KITCHEN . CENTER FOR BOTH SHEATING TYPESIL
I CLII 11
0 7--p p a L ST'S D v
BATH 1 i
8DO
wD 20" s
° LIvING j
" Zee,or
I t ,
.w Ito
R
$ BEDROOMFE� _
rc>1 ENTRY
,aQgp s
DEN
I IP + 2060
sa
117
7 ;
-D068 — J
GARAGE
1
I
L�
11
- 1VORtF•1— � '�j'
J
. y
Project: Paye
Charles D.Smith
Location:GARAGE DOOR /
Multi-Loaded Multi-Span Beam
[2009 International Building Code(2005 NDS)]
3.5 INx12.0INx16.OFT
24F-V4-Visually Graded Western Species-Dry Use
Section Adequate By:79.2% StruCalc Version 8.0.100.0 9/10/2014 11:16:05 AM
Controlling Factor:Deflection LOADING DIAGRAM
DEFLECTIONS Center
Live Load 0.29 IN U667
Dead Load 0.16 in
Total Load 0.45 IN U430
Live Load Deflection Criteria:U360 Total Load Deflection Criteria:U240
REACTIONS A B
Live Load 1307 lb 1573 lb
Dead Load 726 lb 859 Ib
Total Load 2033 Ib 2433 Ib
Bearing Length 0.89 in 1.07 in
BEAM DATA Center
Span Length 16 ft 16ft B
Unbraced Length-Top 2 ft
Unbraced Length-Bottom 16 ft
Live Load Duration Factor 1.00 UNIFORM LOADS Cen er
Camber Adj.Factor 1.5 Uniform Live Load 150 plf
Camber Required 0.24 Uniform Dead Load 75 plf
Notch Depth 0.00 Beam Self Weight 9 plf
MATERIAL PROPERTIES Total Uniform Load 234 pif
24F-V4-Visually Graded Western Species TRAPEZOIDAL LOADS-CENTER SPAN
Base Values Adjusted Load Number One Two
Bending Stress: Fb= 2400 psi Controlled by. Left Live Load 60 plf 0 plf
Fb_cmpr= 1850 psi Fb'= 2386 psi Left Dead Load 30 plf 0 plf
Cd=1.00 C1=0.99 Right Live Load 0 plf 60 plf
Shear Stress: Fv= 265 psi Fv'= 265 psi Right Dead Load 0 plf 30 plf
Cd=1.00 Load Start 11 ft 5 ft
Modulus of Elasticity: E_ . 1800 ksi E'= 1800 ksi Load End 16 ft 16 ft
Min.Mod.of Elasticity: E_min= 930 ksi E_min'= 930 ksi Load Length 5 ft 11 ft
Comp.--to Grain: Fc-1= 650 psi Fc-1'= 650 psi
Controlling Moment: 8766 ft-Ib
8.48 Ft from left support of span 2(Center Span)
Created by combining all dead loads and live loads on span(s)2
Controlling Shear: -2117 lb
At a distance d from right support of span 2(Center Span)
Created by combining all dead loads and live loads on span(s)2
Comparisons with required sections: Read Provided
Section Modulus: 44.08 in3 84 in3
Area(Shear): 11.98 in2 42 in2
Moment of Inertia(deflection): 281.28 in4 5041n4
Moment: 8766 ft-lb 16704 ft-lb
Shear: -2117 lb 74201b
NOTES
.. Page
Project: - Charles D.Smith /
Location:PORCH BEAM
Multi-Loaded Multi-Span Beam
[2009 International Building Code(2005 NDS)] or
3.5 INx5.5INx7.OFT
#2-Douglas-Fir-Larch(North)-Dry Use
Section Adequate By:63.4% StruCalc Version 8.0.100.0 9/10/2014 11:17:36 AM
Controlling Factor:Moment LOADING DIAGRAM
DEFLECTIONS Center
Live Load 0.07 IN U1150
Dead Load 0.04 in
Total Load 0.11 IN L/745
Live Load Deflection Criteria:U360 Total Load Deflection Criteria:U240
REACTIONS A B
Live Load 368 Ib 368 lb
Dead Load 200 Ib 200 Ib
Total Load 567 Ib 567 lb
Bearing Length 0.26 in 0.26 in
BEAM DATA Center
Span Length 7 ft 7f B
Unbraced Length-Top 2 ft
Unbraced Length-Bottom 7 ft
Live Load Duration Factor 1.00 UNIFORM LOADS Center
Notch Depth 0.00 1 Uniform Live Load 105 plf
MATERIAL PROPERTIES Uniform Dead Load 53 plf
#2-Douglas-Fir-Larch(North) Beam Self Weight 4 plf
Base Values Adousted Total Uniform Load 162 plf
Bending Stress: Fb= 850 psi Fb'= 1103 psi
Cd=1.00 C1=1.00 CF=1.30
Shear Stress: Fv= 180 psi Fv'= 180 psi
Cd=1.00
Modulus of Elasticity: E= 1600 ksi E'= 1600 ksi
Min.Mod.of Elasticity: E_min= 580 ksi E_min'= 580 ksi
Comp.-L to Grain: Fc--L= 625 psi Fc--L = 625 psi
Controlling Moment: 993 ft-Ib
3.5 Ft from left support of span 2(Center Span)
Created by combining all dead loads and live loads on span(s)2
Controlling Shear: 499 Ib
At a distance d from left support of span 2(Center Span)
Created by combining all dead loads and live loads on span(s)2
Comparisons with required sections: ReadProvided
Section Modulus: 10.8 in3 17.65 in3
Area(Shear): 4.16 int 19.25 int
Moment of Inertia(deflection): 15.63 in4 48.53 in4
Moment: 993 ft-Ib 1622 ft-lb
Shear: 499 lb 2310 Ib
NOTES
GREEN CROW
LOT 42
BRACE WALLS
Option One— SFB Brace Panels
Minimum length per table R602.10.3(1)
Braced wall line spacing: 30'-0"
Methods — SFB: 8'-6"
Wind adjustment factor: 1.5
Table R602.10.3(2)
Minimum length = 8'-6" X 1.5 = 12'-9"
Option Two — GB Brace Panels
Minimum length per table R602.10.3(1)
Braced wall line spacing: 30'-0"
Methods — SFB: 14'-6"
Wind adjustment factor: 1.5
Table R602.10.3(2)
Minimum length = 14'-6" X 1.5 = 21'-9"
Note:
R602.10.2.3 Minimum number of braced wall panels:
< 16'-0"wall line requires one (1) 48" panel.
> 16'-0"wall line requires two (2) 48" panels. ,
' r? 1<1 ; 6
Maximum spacing between panels in a wall line is 30'-0".
N1
t
Residence
Wall 'A':
SFB Alternate Braced Panels -
Providing total length of 5'-8" of alternate braced panels.
Wall 'B':
GB Brace Panels —
Minimum 21'-9" length required.
30'-0" maximum spacing —
Providing total length of 22'-6" of brace panels.
Wall 'C':
GB Brace Panels —
Minimum 12'-9" length required.
30'-0" maximum spacing —
Providing total length of 22'-0" of brace panels.
Wall 'D':
SFB Brace Panels —
Minimum 12'-9" length required.
30'-0" maximum spacing —
Providing total length of 13'-0" of brace panels.
Wall `1':
SFB Brace Panels —
Minimum 12'-9" length required.
30'-0" maximum spacing —
Providing total length of 16'-0" of brace panels.
Wall '2':
GB Brace Panels —
Minimum 21'-9" length required.
30'-0" maximum spacing —
Providing total length of 22'-0" of brace panels.
v
r
Wall '3':
SFB Brace Panels —
Minimum 12'-9" length required.
30'-0" maximum spacing —
Providing total length of 15'-6" of brace panels.
i
SRACEP PANEL ALTERNATE DRACEP WALL
SFB SHEAR WALL PANELS SF5 ALTERNATE GRACED PANELS
�-I
u
MM I/1" 2582"BTFaJCTl1RAL FI5ER50ARp SHEATHING
I EN 514 , UDOFIBERBOARD SHEATHING T I6 OL.
I�"0�258;TS TRUCTURAL i WITH 1UD8 A
WASTETrEt 16 OL.
FASTENERS
^ ; 2582�ESNTW HINGI 11/2 11
ONG X ODIY DIA
1/2"SHEATHING-1 1/i"LONG X 0.12"DIA.
! I " 1 NAIL EDGES AT 3"ON TER AND FIELD AT b"ON
., ,r• ,.I r 2582"SHEATHING-13/4�LONG X 0.11' DIA CENTER FOR DOTH SHEATMG TYPES
44 CENTER FFORABOTH SHE11 ON CATIt GRTY'�PES IELD AT 6"ON
_ o
� r M.BEDRDOM G5 SHEAR WALL PANELS
�u M�
O 1/2"THICK GYF'SV 50ARD SHEETING I
\/ _ WITH STUDS AT 16"OL
M.BATH FASTENERS
O - 3M 114 3M
INTERIOR LOCATIONS
.. - ; 13 GAGE 13/8 LONG 19/64 HEAD:0098 pIAMETER,
� p�y� p� qd- D;5d ER NAIL
DG OA86�'-D�/�41ETE 15/S' INCa 16/64"{BEAD:O(a
Gy2 �ARP NAIL,0086"bIAMETER 15/S°LONCs,
CAD LGMT eev—J
/ + EXTERIOR LOCATIONS
01 DINING = ; ",° /2 L I V41 REW TYPE 1 WSOR SLE GALVANIZED,
NAIL EDGES AT 1"ON CENTER AND FIELD AT'I"ON
CENTER FOR BOTH SHEATING TYPES
I1
__CLOsDO SET I KITCHEN
-- � —nr�
BATH
E------
^ wo7 5p
20" 0 LIvMG °
26"15p
;7
__ � I
s!
BEDROOM W° LAIMDRY i
o I .AA�86 2863 90308N
ENTRY f
GJW"&,
—1_ lobo i DEN I-1— 1 A)tN, aF
_....i. -..............� + f 1 ry -
sa j' /� rArncccw-
bir
8018 LJ _-
JJ t
. .. .. _. ..NJ 3m
GA, I
I
si
r it 0GAL83, 1/�" I'-O" - ',`a 3^•�
j NO1°a7h1 - �?•
e
Project: pass
Charles D.Smith
Location:GARAGE DOOR /
Multi-Loaded Multi-Span Beam
[2009 International Building Code(2005 NDS)] of
3.5 IN x 12.0 IN x 16.0 FT
24F-V4-Visually Graded Western Species-Dry Use
Section Adequate By:79.2% StruCalc Version 8.0.100.0 9/10/2014 11:16:05 AM
Controlling Factor:Deflection LOADING DIAGRAM
DEFLECTIONS Center
Live Load 0.29 IN U667
Dead Load 0.16 in
Total Load 0.45 IN U430
Live Load Deflection Criteria:U360 Total Load Deflection Criteria:U240
REACTIONS A B
Live Load 1307 Ib 1573 Ib
Dead Load 726 Ib 859 Ib
Total Load 2033 Ib 2433 Ib
Bearing Length 0.89 in 1.07 in
BEAM DA Center
Span Length 16 ft q Asa g
Unbraced Length-Top 2 ft
Unbraced Length-Bottom 16 ft
Live Load Duration Factor 1.00 UNIFORM LOADS Cen er
Camber Adj.Factor 1.5 Uniform Live Load 150 plf
Camber Required 0.24 Uniform Dead Load 75 pif
Notch Depth 0.00 Beam Self Weight 9 plf
MATERIAL PROPERTIES Total Uniform Load 234 plf
24F-V4-Visually Graded Western Species TRAPEZOIDAL LOADS-CENTER SPAN
Base Values Adjusted Load Number One Two
Bending Stress: Fb= 2400 psi Controlled by. Left Live Load 60 pif 0 pif
Fb_cmpr= 1850 psi Fb'= 2386 psi Left Dead Load 30 plf 0 pif
Cd--1.00 C1=0.99 Right Live Load 0 pif 60 plf
Shear Stress: Fv= 265 psi Fv'= 265 psi Right Dead Load 0 plf 30 plf
Cd=1.00 Load Start 11 ft 5 ft
Modulus of Elasticity: E= 1800 ksi E'= 1800 ksi Load End 16 ft 16 ft
Min.Mod.of Elasticity: E_min= 930 ksi E_min'= 930 ksi Load Length 5 ft 11 ft
Comp.-L to Grain: Fc-1= 650 psi Fc--L'= 650 psi
Controlling Moment: 8766 ft-Ib
8.48 Ft from left support of span 2(Center Span)
Created by combining all dead loads and live loads on span(s)2
Controlling Shear: -2117 lb
At a distance d from right support of span 2(Center Span)
Created by combining all dead loads and live loads on span(s)2
Comparisons with required sections: Read Provided
Section Modulus: 44.08 in3 84 in3
Area(Shear): 11.98 int 42 in2
Moment of Inertia(deflection): 281.28 in4 504 in4
Moment: 8766 ft-Ib 16704 ft-Ib
Shear: -2117 Ib 74201b
NOTES
page
Project:
Location:PORCH BEAM „: Charles D.Smith /
Multi-Loaded Multi-Span Beam
[2009 International Building Code(2005 NDS)] or
3.5 IN x 5.5 IN x 7.0 FT
#2-Douglas-Fir-Larch(North)-Dry Use
Section Adequate By:63.4% StruCalc Version 8.0.100.0 9/10/2014 11:17:36 AM
Controlling Factor:Moment LOADING DIAGRAM
DEFLECTIONS Center
Live Load 0.07 IN U1150
Dead Load 0.04 in
Total Load 0.11 IN L/745
Live Load Deflection Criteria:U360 Total Load Deflection Criteria:U240
REACTIONS A B
Live Load 368 Ib 368 Ib
Dead Load 200 Ib 200 Ib
Total Load 567 Ib 567 Ib
Bearing Length 0.26 in 0.26 in
BEAM DATA Center
Span Length 7 ft p -7ft B
Unbraced Length-Top 2 ft
Unbraced Length-Bottom 7 ft
Live Load Duration Factor 1.00 UNIFORM LOADS Center
Notch Depth 0.00 Uniform Live Load 105 plf
MATERIAL PROPERTIES Uniform Dead Load 53 plf
#2-Douglas-Fir-Larch(North) Beam Self Weight 4 plf
Base Values Adiusted Total Uniform Load 162 plf
Bending Stress: Fb= 850 psi Fb'= 1103 psi
Cd=1.00 C1=1.00 CF=1.30
Shear Stress: Fv= 180 psi Fv'= 180 psi
Cd=1.00
Modulus of Elasticity: E= 1600 ksi E'= 1600 ksi
Min.Mod.of Elasticity: E_min= 580 ksi E_min'= 580 ksi
Comp.-L to Grain: Fc-1-= 625 psi Fc-1'= 625 psi
Controlling Moment: 993 ft-Ib
3.5 Ft from left support of span 2(Center Span)
Created by combining all dead loads and live loads on span(s)2
Controlling Shear: 499 Ib
At a distance d from left support of span 2(Center Span)
Created by combining all dead loads and live loads on span(s)2
Comparisons with required sections: Read Provided
Section Modulus: 10.8 in3 17.65 in3
Area(Shear): 4.16 int 19.25 in2
Moment of Inertia(deflection): 15.63 in4 48.53 in4
Moment: 993 ft-Ib 1622 ft-Ib
Shear: 499 Ib 2310 Ib
NOTES