Loading...
HomeMy WebLinkAbout1412 Pendley Court Address: 1412 Pendley Court PREPARED 12/19/14, 9:16:17 INSPECTION TICKET -SAGE 8 CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 12/19/14 --—-----------------------------------------—--------------—------------ ---------- ------- ADDRESS . : 1412 PENDLEY CT SUBDIV: CONTRACTOR : PHONE OWNER CRYSTAL CARMICHAEL PHONE PARCEL 06-30-01-8-6-0020-0000- APPL NUMBER: 13-00001026 RES NEW SFR ------------------------------------------------------------------------------------------------ REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ---- -- ----------------------------------- ME99 01 12/19/14J MECHANICAL FINAL December 19, 2014 9:17:46 AM pbarthol. Bruce 912-0079 PERMIT: PL 00 PLUMBING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ----------------------------------------------------------------------------------- PL6 01 12/05/13 PB PLUMBING WATER SUPPLY 12/06/13 AP December 5, 2013 9:39:07 AM pbarthol. December 6, 2013 9:14:17 AM pbarthol. PL2 01 2/26/14 JLL PLUMBING ROUGH-IN 2/26/14 AP February 26, 2014 10:52:35 AM pbarthol. John 460-6902 February 26, 2014 3:58:02 PM jlierly. PL99 01 12/19/14 J PLUMBING FINAL December 19, 2014 9:17:56 AM pbarthol. Bruce912-0079 -------------------—------ --------- COMMENTS AND NOTES -------------------------------------- PREPARED 12/19/14, 9:16:17 - INSPECTION TICKET PAGE 7 CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 12/19/14 ------------------------------ ADDRESS . : 1412 PENDLEY CT SUBDIV: CONTRACTOR : PHONE OWNER CRYSTAL CARMICHAEL PHONE PARCEL 06-30-01-8-6-0020-0000- APPL NUMBER: 13-00001026 RES NEW SFR ----------- ------------------------------ ------ PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS -- -- ---- - -- ---— BL1 01 11/19/13 JLL BLDG FOUNDATION FOOTING 11/19/13 AP November 19, 2013 8:48:07 AM pbarthol. Bruce 912-0079 November 19, 2013 4:14:44 PM jlierly. BL2 01 11/22/13 PB BLDG FOUNDATION STEM WALL 11/22/13 AP November 22, 2013 8:27:15 AM pbarthol. Bruce 912-0079 November 22, 2013 11:27:41 AM pbarthol. BLFD O1 12/03/13 PB BLDG FOUNDATION DRAINAGE 12/04/13 AP December 3, 2013 9:12:54 AM pbarthol. Bruce 912-0079 December 4, 2013 10:43:48 AM pbarthol. DSD O1 12/04/13 PB BLDG DOWN SPOUT DRAINS 12/04/13 AP December 4, 2013 10:39:05 AM pbarthol. December 5, 2013 9:36:53 AM- pbarthol. PW4 01 12/04/13 RV PUBLIC WORKS STORM 12/04/13 AP December 5, 2013 10:52:52 AM rvess. Foundation perimeter drains and downspouts to swale along Pendley Ct. BFF O1 12/19/13 PB BLDG FLOOR FRAMING 12/20/13 AP December 19, 2013 9:03:50 AM pbarthol. Bruce 912-0079 December 20, 2013 9:37:22 AM pbarthol. BL9 01 1/21/14 PB BLDG SHEARWALL 1/21/14 AP January 21, 2014 9:52:49 AM pbarthol. January 21, 2014 4:47:34 PM pbarthol. BAIR O1 3/07/14 JLL BLDG AIR SEAL 3/07/14 AP March 7, 2014 9:50:10 AM jlierly. bruce March 7, 2014 4:03:53 PM jlierly. BL3 01 3/07/14 JLL BLDG FRAMING 3/07/14 AP March 7, 2014 9:50:31 AM jlierly. March 7, 2014 4:03:53 PM jlierly. BLI O1 3/19/14 JLL BLDG INSULATION 3/19/14 AP March 19, 2014 10:13:58 AM pbarthol. Bruce 912-0079 March 19, 2014 4:21:49 PM jlierly. . PW99 01 12/16/14 RV PUBLIC WORKS FINAL 12/16/14 AP December 16, 2014 2:36:27 PM rvess. December 16, 2014 2:36:58 PM rvess. BL99 01 12/19/14 LL BLDG FINAL December 19, 2014 9:17:37 AM pbarthol. Bruce 912-0079 ------ - ----------------------------------- --------------- -- PERMIT: ME 00 MECHANI ERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ ----------------------------------- CONTINUED ONTO NEXT PAGE ----------------------------------- CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY&ECONOMIC DEVELOPMENT- BUILDING DIVISION =� 321 EAST 5TH STREET, PORT ANGELES, WA 98362 (a� Application Number . . . . . 13-00001026 Date 10/29/13 \" Application pin number . . . 184734 Property Address . . . . . . 1412 PENDLEY CT ASSESSOR PARCEL NUMBER: 06-30-01-8-6-0020-0000- REPORT SALES TAX Application type description RES NEW SFR Subdivision Name . . . . . . on your State excise tax form Property Use to the City of Port Angeles Property Zoning . . . . . . . RS9 RESDNTL SINGLE FAMILY Application valuation . . . . 117568 (Location Code 0502) ---- -------- -------------- --------------------- Application desc 1684 SQ FT SFR ---------------------------------------------------------------------------- Owner Contractor CRYSTAL CARMICHAEL OWNER 1402 C ST #7 PORT ANGELES WA 98363 __- Structure Information 000 000: 1684 SQ FT SFR --- \ Permit . . . . . . BUILDING PERMIT -RESIDENTIAL Additional desc . . 1684 SQ FT SFR Permit Fee . . . . 1121.05. Plan Check Fee 728.68 Issue Date 10/29/13 . Valuation . . . . 117568 Expiration Date 4/27/14 Qty Unit Charge Per Extension BASE FEE 1020.25 18.00 5.6000 THOU BL-100,001-_500K (5.60. PER K) 100.80 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL PERMIT Additional desc . Permit Fee . . . . 141.60 Plan Check Fee .00 Issue Date . . . . 10/29/13 Valuation 0 Expiration Date 4/27/14 Qty Unit Charge Per Extension BASE FEE 50.00 1.00 14.8000 EA ME-FURN/HP/FAU < OR = 5 TON 14.80 3.00 7.2500 EA ME-VENT FAN (SINGLE DUCT) 21.75 1.00 10.6500 EA ME-HOOD/DUCT-MECH. EXHAUST 10.65 3.00 14.8000 EA ME-HEATER(SUSP/WALL/FLOOR-MTD) 44.40 ---------------------------------------------------------------------------- Permit . . . . . . PLUMBING PERMIT Additional desc . . Permit Fee . . 163.00 Plan Check Fee .00 Issue Date . . . . 10/29/13 Valuation 0 Expiration Date . . 4/27/14 Qty Unit Charge Per Extension BASE FEE 5.0_.00 8.00 7.0000 EA PL-PLUMBING TRAP 56.00 1.00 7.0000 EA PL-WATER LINE 7.60 f Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes nul I and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced, or if required-inspections have not been.requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder) T:Forms/Building Division/Building Permit BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS— Building Inspections 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION: Footings Stemwall Foundation Drainage/Downspouts Piers Post Holes(Pole Bldgs.) PLUMBING: Under Floor/Slab Rough-in Water Line(Meter to Bldg) Gas Line Back Flow/Water FINAL Date Accepted b AIR SEAL: Walls Ceiling FRAMING: Joists/Girders/Under Floor Shear Wall/Hold Downs Walls/Roof/Ceiling Drywall Interior Braced Panel Only) T-Bar INSULATION: Slab Wall/Floor/Ceiling MECHANICAL: Heat Pum /Furnace/FAU/Ducts Rough-In Gas Line Wood Stove/Pellet/Chimney Commercial Hood/Ducts FINAL Date Accepted b MANUFACTURED HOMES: Footing/Slab Blocking&Hold Downs Skirting PLANNING DEPT. Separate Permit#s SEPA: Parkin /Lighting ESA: Landscaping SHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE Inspection Type Date Accepted By Electrical 417-4735 Construction-R.W. PW /Engineering 417-4831 Fire 417-4653 Planning 417-4750 Building 417-4815 T:Forms/Building Division/Building Permit CITY OF PORT ANGELES ` INCDEPARTMENT OF COMMUNITY& ECONOMIC DEVELOPMENT- BUILDING DIVISION ' 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Page 2 Application Number . . . . . 13-00001026 Date 10/29/13 Application pin number . . . 184734 REPORT SALES TAX Qty Unit Charge Per Extension on our state excise tax form 4.00 7.0000 EA PL-DRAIN VENT PIPING 28.00 y 1.00 15.0000 EA PL-SEWER LINE 15.00 to the City of Port Angeles 1.00 7.0000 EA PL-WATER HEATER7.00 - (Location Code 0$02) Special Notes and Comments September 13, 2013 1.:45:51 PM pbarthol. Only one set of plans reviewed for this home design. The reviewed set of plans must be available on all three building sites. Plan check fee for this design paid for on permit 13-1026 (includes 13-1028, 13-1027, 13-1026) September 17, 2013 7:25:16 AM rbecker. If you are installing a lawn sprinkler system, contact me. Ron Becker at 360-417-4886, .fax:360-452-4972, or e-mail:rbecker@cityofpa.us Address numbers shall be plainly visible from the street. Address numbers shall be a minimum of six inches high and be of contrasting color from the background. All homes in new subdivisions that are outside of the Fire Department four-minute response. area shall be equipped with residential fire sprinkler systems that comply with the International Fire Code (IFC) and National Fire Protection Association (NFPA) . September 13, 2013 4:23:24 PM banders. Electrical connection point is at the northeast corner of property. Electrical load calculations and electrical permits are required. Ditches & 12" culverts will be installed to City Stanards. See Public Works Engineering for Standards. Consider applying for the City Green Infrastructure Rebate of up to $500.00 towards the materials to install, rain garden to control roof and driveway runoff. Contact Jonathan Boehme at 360 417-4811 Trench safety per applicable laws. Temp erosion control and surface restoration responsibility of applicant: Contact City inspector prior to start of work @ 360 417-4831. No attachment to sanitary sewer of stormwater roof leaders, foundation drains, yard drains, or any other CSO contribution is allowed. Sanitary sewer connection inspection is required by Public Works prior to back fill of ditch. 24 hour advance notice is required. Public Works Inspection request line 417-4831 Construct driveway to City Standards. Concrete with exposed aggregate or other non-standard finishes(including colors or dyes)are not allowed in the City road right of way. Broom finish only. An inspection by Public Works Engineering is required prior to pouring concrete. Public Works inspection Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within,180,days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced, or if required.inspections.have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws.and ordinances governing this type of work will be complied with whether specified herein or.not. The granting of a permit does not preume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder) T:Forms/Building Division/Building Permit BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS— Building Inspections_ 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL,TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION: Footings Stemwall Foundation Drainage/Downspouts Piers Post Holes(Pole Bldgs.) PLUMBING: Under Floor/Slab Rough-in Water Line(Meter to Bldg) Gas Line Back Flow/Water FINAL Date Accepted b AIR SEAL: Walls Ceiling FRAMING: Joists/Girders/Under Floor Shear Wall/Hold Downs Walls/Roof/Ceiling Drywall Interior Braced Panel Only) T-Bar INSULATION: Slab Wall/Floor/Ceiling MECHANICAL: Heat Pum /Furnace/FAU/Ducts Rough-in Gas Line Wood Stove/Pellet/Chimney Commercial Hood/Ducts FINAL Date Accepted b MANUFACTURED HOMES: Footing/Slab Blocking&Hold Downs Skirting PLANNING DEPT. Separate Permit#s SEPA: Parking/Lighting ESA: Landscaping SHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE Inspection Type Date Accepted By Electrical 417-4735 Construction-R.W. PW /Engineering 417-4831 Fire 417-4653 Planning 417-4750 Building 417-4815 T:Forms/Building Division/Building Permit % CITY OF PORT ANGELES i DEPARTMENT OF COMMUNITY& ECONOMIC DEVELOPMENT- BUILDING DIVISION _ 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Page 3 Application Number . . . . . 13-00001026 Date 10/29/13 Application pin number . . . 1.84734 ----------- ---------------------------------------------------- REPORT SALES TAX Special Notes and Comments request line 417-4831 on your state excise tax form -- ---------------- ---- - - ------- --- --- -- ----- - Other Fees RES UNDERGRND SERVICE FEE----770-.00----- to the City of Port Angeles SEWER SYSTEM DELV CHARGE 2260.00 (Location Code 0502) STATE SURCHARGE 4.50 PW WATER SYSTEM USE FEE 2260.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 1425.65 1425.65 .00 .00 Plan Check Total 728.68 728.68 .00 .00 Other Fee Total 5294.50 5294.50 .00 .00 Grand Total 7448.83 7448.83 .00 .00 Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within.180:days,if construction or.work is suspended or abandoned for a period of 180 days after the work'has commenced,or if required inspections have not been.requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder) T:Forms/Building Division/Building Permit BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS– Building Inspections 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL.TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION: Footings Stemwall Foundation Drainage/Downspouts Piers Post Holes(Pole Bldgs.) PLUMBING: Under Floor/Slab Rou h-In Water Line(Meter to Bid Gas Line Back Flow/Water FINAL Date Accepted b AIR SEAL: Walls Ceiling FRAMING: Joists/Girders/Under Floor Shear Wall/Hold Downs Walls/Roof/Ceiling D all(Interior Braced Panel Onl T-Bar INSULATION: Slab Wall/Floor/Ceiling MECHANICAL: Heat Pum /Furnace/FAU/Ducts Rou h-In Gas Line Wood Stove/Pellet/Chimne Commercial Hood/Ducts MANUFACTURED HOMES: FINAL Date Accepted b Footin /Slab Blockin &Hold Downs Skirting PLANNING DEPT. Separate Permit#s Parkin SEPA: /Li htin Landscaping ESA: SHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE Inspection Type Date Accepted By Electrical 417-4735 Construction-R.W. PW I Engineering 417-4831 Fire 417-4653 —Planning 417-4750 Building 417-4815 T:Forms/Building Division/Building Permit OF PORT qNC CITY OF PORT ANGELES PUBLIC WORKS & UTILITIES c� 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Application Number . . . . . 13-00001026 Date 10/29/13 Application pin number . . . 184734 Property Address . . . . . . 1412 PENDLEY CT ASSESSOR PARCEL NUMBER: 06-30-01-8-6-0020-0000- REPORT SALES TAX Application type description RES NEW SFR on your state excise tax form Subdivision Name . . . . . . Property Use . . . . . . . . to the City of Port Angeles Property Zoning . . . . . . . RS9 RESDNTL SINGLE FAMILY (Location Code 0502) Application valuation . . . . 117568 ---------------------------------------------------------------------------- Application desc 1684 SQ FT SFR ---------------------------------------------------------------------------- Owner Contractor CRYSTAL CARMICHAEL OWNER 1402 C ST #7 PORT ANGELES WA 98363 --- Structure Information 000 000 1684 SQ FT SFR --- ---------------------------------------------------------------------------- Permit . . . . . . DRIVEWAY INSTALLATION Additional desc . . DRIVEWAY AND 12" CULVERTS Permit Fee . . . . 180.00 Plan Check Fee .00 Issue Date . . . . 10/29/13 Valuation . . . . 0 Expiration Date 4/27/14 Qty Unit Charge Per Extension BASE FEE 180.00 ------------------------------------------------------------------------ Permit . . . . . . PUBLIC WORKS RES WATER SERV Additional desc . . 3/4" METER FOR FIRE SPRINKLERS Permit Fee . . . . 420.00 Plan Check Fee .00 Issue Date . . . . 10/29/13 Valuation . . . . 117568 Expiration Date 4/27/14 Qty Unit Charge Per Extension 1.00 420.0000 EA PW WATER METER DROP IN 420.00 ---------------------------------------------------------------------------- Permit . . . . . . SANITARY SEWER HOOK UP Additional desc . Permit Fee . . . . 150.00 Plan Check Fee .00 Issue Date . . . . 10/29/13 Valuation . . . . 117568 Expiration Date 4/27/14 Qty Unit Charge Per Extension 1.00 150.0000 EA SAN SEWER HOOKUP 150.00 ---------------------------------------------------------------------------- Special Notes and Comments September 13, 2013 1:45:51 PM pbarthol. Only one set of plans reviewed for this home design. The reviewed set of plans must be available on all three building sites. Plan check fee for this design Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned for a period of 180 days after the work as commenced,or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct.,All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. 7)--- z,/m2 y 3 Signature of Contractor or thorized Agent Date Signature of Owner(if owner is builder) Date T:Forms/Building Division/Public Works Permit PERMIT INSPECTION RECORD CALL 417-4831 FOR UTILITY INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INA CONSPICUOUS LOCATION. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED COMMENTS YES NO PW UTILITIES (Engineering Division) WATERLINE/METER SEWER CONNECTION SANITARY STORM SITE DRAINAGE SITE EROSION CONTROL PARKING SIDEWALK CURB&GUTTER DRIVEWAY APPROACH BACK-FLOW DEVICE FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED YES I NO CONSTRUCTION R.W./PW/ CONSTRUCTION-R.W. ENGINEERING 417-4807. PW/ENGINEERING FIRE 417-4653 FIRE DEPT. PLANNING DEPT. 417-4750 PLANNING DEPT. BUILDING 417- BUILDING 4815 T:Forms/Building Division/Public Works Permit OF pORT,y,I,C CITY OF PORT ANGELES PUBLIC WORKS & UTILITIES v 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Page 2 Application Number . . . . . 13-00001026 Date 10/29/13 Application pin number . . . 184734 REPORT SALES TAX ---------------------------------------------------------------------------- Special Notes and Comments on your state excise tax form paid for on permit 13-1026 (includes 13-1028, 13-1027, 13-1026) to the City of Port Angeles September 17, 2013 7:25:16 AM rbecker. Location Code 0502) If you are installing a lawn sprinkler system, contact me. Ron Becker at 360-417-4886, fax:360-452-4972, or e-mail:rbecker@cityofpa.us Address numbers shall be plainly visible from the street. Address numbers shall be a minimum of six inches high and be of contrasting color from the background. All homes in new subdivisions that are outside of the Fire Department four-minute response area shall be equipped with residential fire sprinkler systems that comply with the International Fire Code (IFC) and National Fire Protection Association (NFPA) . September 13, 2013 4:23:24 PM handers. Electrical connection point is at the northeast corner of property. Electrical load calculations and electrical permits are required. Ditches & 12" culverts will be installed to City Stanards. See Public Works Engineering for Standards. Consider applying for the City Green Infrastructure Rebate of up to $500.00 towards the materials to install rain garden to control roof and driveway runoff. Contact Jonathan Boehme at 360 417-4811 Trench safety per applicable laws. Temp erosion control and surface restoration responsibility of applicant. Contact City inspector prior to start of work @ 360 417-4831. No attachment to sanitary sewer of stormwater roof leaders, foundation drains, yard drains, or any other CSO contribution is allowed. Sanitary sewer connection inspection is required by Public Works prior to back fill of ditch. 24 hour advance notice is required. Public Works Inspection request line 417-4831 Construct driveway to City Standards. Concrete with exposed aggregate or other non-standard finishes(including colors or dyes)are not allowed in the City road right of way. Broom finish only. An inspection by Public Works Engineering is required prior to pouring concrete. Public Works inspection request line 417-4831 ---------------------------------------------------------------------------- Other Fees . . . . . . RES UNDERGRND SERVICE FEE 770.00 SEWER SYSTEM DELV CHARGE 2260.00 STATE SURCHARGE 4.50 PW WATER SYSTEM USE FEE 2260.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 750.00 750.00 .00 .00 Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned for a period of 180 days after the work as commenced,or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Signature of Contractor or Authorized Agent Date Signature of Owner(if owner is builder) Date T:Forms/Building Division/Public Works Permit PERMIT INSPECTION RECORD CALL 417-4831 FOR UTILITY INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INA CONSPICUOUS LOCATION. KEEP PERMIT CARD AND.APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED COMMENTS YES NO PW UTILITIES (Engineering Division) WATERLINE/METER SEWER CONNECTION SANITARY STORM SITE DRAINAGE SITE EROSION CONTROL PARKING SIDEWALK CURB&GUTTER DRIVEWAY APPROACH BACK-FLOW DEVICE FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED YES NO CONSTRUCTION R.W./PW/ CONSTRUCTION-R.W. ENGINEERING 4174807 PW/ENGINEERING FIRE 417-4653 FIRE DEPT. PLANNING DEPT. 417-4750 PLANNING DEPT. BUILDING 47- BUILDING 4815 T:Forms/Building Division/Public Works Permit CITY OF PORT ANGELES PUBLIC WORKS & UTILITIES � v 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Page 3 Application Number . . . . . 13-00001026 Date 10/29/13 Application pin number . . 184734 REPORT SALES TAX Plan Check Total .00 .00 .00 .00 Other Fee Total 5294.50 5294.50 .00 .00 on your state excise tax form Grand Total 6044.50 6044.50 .00 .00 to the City of Port Angeles (Location Code 0502) Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work as commenced,or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Signature of Contractor or Authorized Agent Date Signature of Owner(if owner is builder) Date T:Forms/Building Division/Public Works Permit PERMIT INSPECTION RECORD CALL 417-4831 FOR UTILITY INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED COMMENTS YES NO PW UTILITIES (Engineering Division) WATERLINE/METER SEWER CONNECTION SANITARY STORM SITE DRAINAGE SITE EROSION CONTROL PARKING SIDEWALK CURB&GUTTER DRIVEWAY APPROACH BACK-FLOW DEVICE FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED YES NO CONSTRUCTION R.W./PW/ CONSTRUCTION'-R.W. ENGINEERING 417-4807 PW/ENGINEERING FIRE 417-4653 FIRE DEPT. PLANNING DEPT. 4174750 PLANNING DEPT. BUILDING 4b7- BUILDING 4815 T:Forms/Building Division/Public Works Permit kE f' CITYOF ,; :. \\ For City Use W A S H I N G T O N , U . S . Permit# > 07—Co Date Received: 321 East 51h Street Port Angeles, WA 98362 Date Approved 0 6 j P: 360-417-4817 F: 360-417-4711 permits@cityofpa.us Building Permit Application Project Address: /q/ �L, (��„lDs. y covl2r Main Contact: Co-tsTRve-r► o4 sunk.Vi sC>rt Phone # 9/ a - 007? E-Mail: b ,)le- en (Fran insu ic-,. ,o Property Name- , Phone Owner CAY-s If AYP7 i e l4 £. L Mailing Address Email 7 city. State Zip Contractor Name Phone 0wIV L ?- /3UIt Ds-K Mailing Address Email city State ZIP Contractor License # Expiration: Project Value: Zoning: Tax Parcel # Lot# $ 17 Jl�/'g O6 30 n f O 0,J-0 Type of Residential Commercial ❑ Industrial ❑ Public ❑ Permit Demolition ❑ Fire ❑ Repair ❑ Reroof(tear off/lay over) ❑ For the following, fill out both pages of permit application: New Construction M"' Remodel ❑ Addition ❑ Tenant Improvement ❑ Mechanical ❑ Plumbing ❑ Other ❑ Existing Fire Sprinkler System? Maximum height of structure Proposed Bedrooms Proposed Bathrooms Yes ❑ No ❑ //' /=2'£T Project AIi SSL-) S1 N 6-A Description r=f}r>7 .� S i D£^/`. I have read and completed the application and know it to be true and correct.I am authorized to apply for this permit. I understand that it is my responsibility to determine what permits are required and to obtain permits prior to working on projects. I understand that the plan review fee is not refundable after plan review has occurred. I understand that I will forfeit the review fee if I cancel or withdraw the application before the permit is issued. I understand that if the permit is not issued within 180 days of receipt,the application will be considered abandoned and the fees forfeit. Date Print Name Signature 1 Residential Structures For Office Use Area Description (SQ FT) Existing Proposed $$value Basement First Floor / 1 Yn /0J yoo Second Floor " Covered Deck/Porch/Entry i G / 7Gg Deck Garage yoo Carport Other(describe) Area Totals / $ q 7 .CCB Commercial Structures For Office Use Area Descriptions (SQ FT) Existing Proposed $$Value Existing Structure (s) Proposed Addition Tenant Improvement? Other work(describe) Area Totals Lot/Site Coverage Calculations Footprint(SQ FT) of all Structures: Lot Size: %Lot Coverage SQ FT Site coverage (qjI impervious+ %Site Coverage structures ���G Mechanical Fixtures Indicate how many of each type of fixture to be installed or relocated as part of this project. Air Handler Size: # Haz/Non-Haz Piping #of Outlets: Appliance Vent # Heater(Suspended,Floor,Recessed wall) # `-� Boiler/Compressor Size: # Heating/Cooling appliance # J repair/alteration Evaporative Cooler(attached,not # Pellet Stove/Wood-burning/Gas # portable) Fireplace/Gas Stove Gas Cook Stove/Misc. Fuel Gas Piping #of Outlets: Ventilation Fan,single duct # 3 Furnace eat Pu Size: # Ventilation System # Forced Airmt la Ooo Plumbing Fixtures Indicate how many of each type of fixture to be installed or relocated Plumbing Traps # fQ Fuel gas piping #of Outlets: Water Heater # r Medical gas piping #of Outlets: Water Line # Vent piping # Sewer Line # i Industrial waste pretreatment # 1 interceptor Other(describe): T:\BUILDING\APPLICATION FORMS\BUILDING PERMIT 081212.DOCX co r- I I , 35' 35' I FND. i"CONDUIT WITH PLASTIC CAP FND. i"CONDUIT WITH PLASTIC CAP I 35' 35' STAMPED "CLARK 12223", N8754'21"W, STAMPED=CLARK 12223", S08'30'15"W, 0.21'FROM CALCULATED POSITION .--,-0.27'FROM-C-A6C(ULATED POSITION N 33'14'39"E 669.64 8' 95;00 53.00'N N 706.65' 76.00'N 81.00' 85.60' / 85.80' 86.60' I HOUR 10 . 9 � Jowo mg� BI' — � (n / 3 -9 , FND. 2"E9016 SOFT oLnF6 625SQ.FTI 25' 5 9046 SQ.FT� T.. T8 o ,9003 SQ.Fu 7 WTH PL® O( is10288 SQ.FT. �® 422 20 IN 12 8 Ili ni gm —9500, Jg N g V1 VNi ' 533-14'40-W 21.1843 2 85.80 66.61 _ 81.35 �fi O. 0 42.67 ..'.':::.'::.'.':C4 .'.. .'.'.'.'.'.'.'.'::::.'.'::.'.'.':.:':.'.'.:'.'.: .':::..,......................G'h ti 2.� 1 61 ........... c>C ... ... ... ..:::. :::.'.'.' '. N...::o rn N i 16 a o N .�.,. N 33'14'15" E:':'rc....r..-::...0 I m ........................ ..............N....... ... ..�...., ........ .......�.. O 8 N 2758'33" E(':'r. ........ ...... (A ��/ 025 SQ.F7� (o ..S 33'14'15' W: .'.':.'.'.'.':.. _'..' x......250.81':r.:.'r:r.':.'.'.':.'..'r:r.o -� Ed yy I II - 33'14 15 — .........145,20':':': : w:.':.'.. G u �1 ss.o7 ss.si'::': :':':':'C2. C6CIRT. o w. . . m 111 :. .:........................... .......... . c15 ,cis..... . ............................ ......................... 1 � � �..... ............................. c; qi 10 Q.::. �12: C13.'C14.........':............... 72.67 65.20' 74.75,.. 55_84•.. A 533'1442 W AI co .'. �, ,j1:;:;: i0.61" 8 723• 2� 10N — 10 8I �� I N 14 e �7 C `o cn I Z 18, I >. FND. I 2"REBAR W1711 25'.2yal W!6 8 3 10 �- �� 12 _�, l3 L' 14 7 PLASTIC CAP 0.14'FROM �O 10781 SQ.FT. �"°i� (o �o n3 IS 8' 0 9053 SQ.FT. N 9031 SQ.FT. 9007 SQ.FT. 9006 SQ.FT. tp P 9075 SQ.FT. awl �� u�I k� f��l I��a CALCULATED POSITION o 9025 SQ. a. ,o �— IN i STAMPED "CUMMINS LS 9042 �—°'('' V77'�"l �22329 N60'02'3 �_ L10' N $ NN 78.64' 109.02 • 83.25' U U 77.75' 75.38'�U U 75.85 I FND. N 33'14'44" EI CAP I . 669.66' 0630( SE COR. FOUND 1/2"REBAR AND KI TH PLASTIC CAP cn N SUB LOT 79 ,?' CAP "Z&A PLS 28071" o FND. i"CONDUIT STAMPED "CLARK 12223", S65'22'58"W, I o� <. 0.18'FROM CALCULATED POSITION e ? 110 u , : ons 250' - v 12 z r 533 1,4 '09 I� 213,g5,50 ,5ite Plan r=;20.0'. 1412 m4pLE)-6bu vw NoR-�J POI'ZT AN( ELE,5,IVa 98363 COUNT-(OF CL4LL4M PLOLLY COURT LOT 2 LOT COVEP-4(;E 684/9olo5F= 18:740 51TE COVE 2620/9olo6F = 2940 DOUSE STYLE:TIJ L'DOROTLjY,4 'z yOw QOR7.+� , r,F PRESCRIPTIVE APPROACH-SIMPLE FORM For the Washington State Energy Code (WSEC) 2009 Edition Climate Zone I CITY aOVERNIkENT Site Information: Building Department Use Only: Lot: 2 /f&,-J o), y g-3,f . Permit # Address: 11112, &&I D).E y Co o1fr Notes: City: Pn2(i­ �+�G State: Zip: Contact: 690r"_1 /h e Cc, 1010911 / Phone: 9/ ; — 007 9 Phone 2: y)�2 FAX: :A WSEC Table 6-1 PRESCRIPTIVE REQUIREMENTS FOR SINGLE-FAMILY RESIDENTIAL OR DUPLEX CLIMATE ZONE 1 (Unlimited Glazing Option Only) Glazing Glazing U Factor Door Vllall ZA Wall Wall Vaulted Interior. Ext6rlor Slab on Option Area'/o of u- Ceiling C Alove Floor Floor Vertical Overhead Factor eilmg Grade Below Below Concrete r Grade G?ade R-49 / III Unlimited 0.30 0.50 0.20 or R-38 R-38 int TB R-21 R-21 R-10 R-30 R-10 U=0.029 2' adv This Project complies with the following: The project is a single-family residence or duplex. The project is a wood frame OR all of the insulation is interior or exterior of the framing. All building components meet the requirements listed above. The project will meet all other provisions of the WSEC and VIAQ. The Project will take advantage of the following exceptions to the prescriptive option. ❑ 602.6 Exception 2. One unlabeled or untested exterior swinging door, 24 sq.ft. or less, may be installed per unit for ornamental, security, or architectural purposes. Location of the.door taking this exception: ❑ 602.6 Exception 2. If a door is mostly glass, it should meet the requirement of the vertical glazing U-factor listed above. Location of the door(s)taking exception: i /,1/Ml-51,LI'T Type of Heat Source: Due-TLf SS HEIR PUMP 1a01V4L Cv41-1- T:Forms/Building Division/Prescriptive Approach-Simple Form 2013-1301872 page 1 of 2 Warranty Deed Ol ympi0 Peninsula Title Company Clallam County Washington 10/25/2013 04:16:38 PM ■IIIPrAIf1i��.l il����+'��f'��;I �R1,4ki l•KYIi�,lIIII OLYMPIC PENINSULA Title Company O O NU CLALLAM COUN Y TRANSACTION EX I TAX DATE Escrow Number:101416-DS PAID T 2 5 A N1 5 al'-, Statutory Warranty Deed IS N%. I P. THE GRANTOR Housing Authority of the County of Clallam for and i co era' no COLLARS AND OTHER GOOD AND VALUABLE CONSIDERATION in hand ai ,conve an warra Crystal Carmichael,an unmarried individual the following described real esta e,situated in e County of Clallam, State of Washington. Abbreviated Legal: LOT 2, PENDLEY ESTATES For Full Legal See Attached Exhibit"A" Subject to exceptions to title also appearing on Exhibit"A Tax Parcel Number(s):06-30-99-107910/70571, -30-,001-181600210/82922(New Assigned Parcel No.) Dated October 22,2013 sing Auth rity of the C my lallam y: Pamela J.Ti E ecutive ctor STATE OF WASHINGTO } COUNTY OF CLA M } SS: I certify that I knoha ah cto nce that Pamela J.Tietz is/are the person(s) who appeared before me,and saidp n ac wledge t she signed this instrument,on oath she is/are author.. to th ' strument and acknowledge that as the Executiv i r of Housing Authority of the Co allam to be the free an v lun act of s party(ies)for the;usesdurposes ned in t is instrument. 7 Dated: Oct 201 o DawnNotnd for the State of Washington Residing at Port Angeles My appointment expires: 4-9-2015 LPB 10-05(i-1) Page I of 2 " 2013-1301872 10/25/2013 04:16:38 PM 2 of 2 Clallam County, WAWD OLYMPIC PENINSULA TITLE COMPANY EXHIBIT A LOT 2 OF PENDLEY ESTATES,AS PER PLAT THEREOF RECORDED IN VOLUM I PLATS,PAGE 78,RECORDS OF CLALLAM COUNTY,WASHINGTON. O SITUATE IN CLALLAM COUNTY,STATE OF WASHINGTON. SUBJECT TO: I. ALL COVENANTS,CONDITIONS,RESTRICTIONS,RESERVATIONS,E EMEN R OTHER SERVITUDES,IF ANY,DISCLOSED BY THE RECORDED PLA P ESTATES. 2. ALL COVENANTS,CONDITIONS,RESTRICTIONS,RESERVATIO TS OR OTHER SERVITUDES,IF ANY,DISCLOSED BY SHORT PLAT RE RDED R CLALLAM COUNTY RECORDING NO.515919. 3. COVENANTS,FOR MAINTENANCE,REPAIR AND OPERATION OF INAGE FACILITIES,CONDITIONS AND RESTRICTIONS IMPOSED Y O ORDED UNDER CLALLAM COUNTY RECORDING NO. 2013-129 O i 0 LPB 10-050-1) Page 2 of 2 Prescri tive Energy Code Compliance for Single Family and Duplex Housing:Zone.1 Project Information Contact Information Pendley Court -r '2- Peninsula Housing Authority Port Angeles, WA 2603 S Francis St Clallam County Port Angeles, WA 98362 This set of forms has been developed to assist permit applicants documenting compliance with the Washington State Energy Code, (2009 edition). This set is for structures built under the IRC and located in Climate Zone 1. The following forms provide much of the required,documentation for plan review. The details noted here must also be shown on the drawings(WSEC 104:2). " This form is not a substitute for the energy code itself..To obtain a copy of.the energy code, go to the following web address. http://www.ene�gy.wsp.edu/code Glazing 10 Glazing U-Factor 9" Vaulted Wall1Z Wall into Wall-ext4 SIA'.O tion Area ,.. Door z Above Below Below Floors on P o U-Factor Ceiling Ceiling' /o of Floor Vertical Overhead Grade Grade Grade Grade R-49 or R-21 R-21 R-10 01 13% 0.34 0.50.. 0.20 R-38 R-38 Int. -TB 7R-4 0 R-30 2 Adv R-49 or R-21. R-21 R-10 01I 25% 0.32 0.50.. 0.20 R48 R-38 Int. 10 R TB R- ' -30 2 Adv. R-49 or R-21 R-21 R-10 Q III Unlimited 0.30 0.50 0.20 R-38 R-38 7 R-10 R-30 Adv: Int. TB 2. See WSEC table 6-1 for footnotes Glazing Schedule Attached to Document Does not apply. (SEE INSTRUCTIONS) Using Prescriptive Option lll.All glazing and P doors meet maximum U-factor.Alternate.heating size method submitted: . ❑ Option I or II, Glazing to floor area limit(WSEC 602.7.2) ❑ Area weighted window,skylight or door U-factor(WSEC 6M.1.2). ❑ As part of the. heating system sizing calculation (IRC M1401.3.&WSEC 503.2.2) Radiant slab: ❑ R-10 foam insulation, continuous with thermal break (WSEC 502.1.4.9) Chapter 9 Options Total of 1 Credit Required Opt. Opt. Description la High Efficiency HVAC Equipment 1.. ❑ lb High Efficiency HVAC Equipment 2. ❑ 1c High Efficiency HVAC Equipment 3. ❑ 2 Hi h Efficiency HVAC Distribution System ❑ . 3a Efficient Building Envelo e.1 ❑ 3b Efficient Building Envelope.2 ❑ 3c Super-Efficient Building Envelope 3 ❑ 4a Air Leakage Control and Efficient Ventilation ❑ 4b Additional Air Leakage Control and Efficient Ventilation ❑ 5a Efficient Water Heating ❑ 5b High Effieciency Water Heatin ❑ 6 Small Dwelling Unit 1.0 7 Large Dwelling Unit ❑ 8 Renewable Electric Ener - *1200 kwh ❑ . Total Credits 1.00 WSEC Prescriptive Worksheet(2010 edition)Zone 1 WSUEEP10-010 Copyright 2010 Simple.Hgating System Size: Climate Zone 1 Project Information Contact Information Pendley Court Peninsula Housing Authority "The Sheila" 2603 S Francis St Port Angeles, WA 98363 Port Angeles, WA 98362 Indoor Design Temperature 70 Outdoor Design Temperature 28 Design Temperature Difference(AT) AT=indoor-Outdoor Design Temp 42 Conditioned Floor Area 1 1240 Conditioned Volume 9920 Glazing Copy.Sum of UA from Glazing Schedule 0 Attic U-Factor X Area = UA R-49 0.027 1240 33.5 R-38 Advanced 0.026 Single Rafter or Joist Vaulted Ceilings U-Factor X Area = UA R-38 Vented 0.027 Above Grade Walls U-Factor X Area = UA R-21 0.056 1288 72.1 Floors U-Factor X Area 1UA R-30 0.029 1240 36.0 Below Grade Walls U-Factor X Area = UA 2' Depth Walls 0.042 3.5' Depth Walls 0.041 7' Depth Walls 0.037 Slab Below Grade F-Factor X Length = UA 2' Depth 0.59 3.5' Depth 0.64 7' Depth 0.57 Slab on Grade F-Factor X Length = UA R-10 2' perimeter 0.54 R-10 Full - Heated 0.55 Sum of UA 142 Envelope Heat Load 5946 Btu/ Hour Sum of UA X AT Air Leakage Heat Load 4500 Btu/ Hour ((Volume X 0.6)X OT)X.018)) Building Design Heat Load 1 10446 Btu/Hour Air Leakage+Envelope Heat Loss Building and Duct Heat Load 0 10446 Btu/Hour If ducts are located in unconditioned space:Sum of Building Heat Loss X 1.15 If ducts are located in conditioned space:Sum of Building Heat toss X 1 Maximum Heat Equipment Output 150% -, 156681 Btu/Hour. Building and Duct Heat Loss X 1.50 WSEC Prescriptive Worksheet(2010 Edition) WSUEEP10-010 Copyright 2010 �/► �`f s ® . CD Electrical Information Form ®4 Public Works&Utilities Department(360)417-4700 m Cf(1RK56LS City Electrical Inspector(360)417-4735 Please complete and return to Public Works& Utilities Department Permanent service: Name: C AY 5'1i-7 4 e 4AM/CI AAZ i, Name and address of party Street: �Lf!J-,� S�?. C_ 3`j 7 responsible for permanent City/ State/ ZIP: oP-r d%g£4QS tv4. service billing? Da ime Phone: Yt Home Phone: • • • (if other than above) Site contact: Name: QR�Je£ Inc C o P>r•,/ Title: Co�t15�' Sc�(u�R V/S a✓Z f� Daytime Phone: / Contractor: Name: OtuAl M -(3V ji-o '-/Company: P£.vl.,/s u44 Ncvsi. 4 u;y. Daytime Phone: Electrician: Name: Company: Daytime Phone.- Excavator: hone:Excavator: Name: Company: Daytime Phone: rningle ❑Existing New -family residence ElMulti-family residence; #of units mmercial DSubdivision; #of lots i? ElOOverhead service ❑General service Underground service ❑Other: • • • D� ioncriptof work: Street address/lot number: S F) c..�/e �. " 3 go S q Ft 4'r<4e-H C p enqIZ de— Nearest cross street: Desired connection date: Electrical transformer serving property is: ❑on a pole on the ground Total square footage: a�0 sq.ft. Main disconnect size: e10o amps Voltage: 120/240 1ph 0120/208 3ph E1277/480 3ph ❑120/240 3ph 0480 3W 3ph El Other Standard residential loads (Lighting, refrigerator, dishwasher, washer) Check all that apply: El A/C (_ton) E?L7 nge/Oven ❑Hot Tub i lothes Dryer Heating []Pumps Hp) ❑No Load Change Water Heater ❑Elevator(_Hp) ❑Other • ' 4 9 • Please provide a copy of the following: *Detailed plot plan (.dwg or.dxf format mandatory for subdivisions). *Electrical one-line drawing showing the service entrance panel and location. *Connected load data. *Size and locked rotor amps of all motors over 50hp. Applicant's Signature: Date: MAIL OR DELIVER COMPLETED FORM TO: 321 E 5TH STREET; PORT ANGELES, WA 98362 FAX TO: 360-417-471 WS Information form.'--'!s WF iv:`.,P'.!4'�(:>;(_IGHT'•�_NGR';e!(, .. ':;iS`;�!if Olrr... .`;:Mfr F;F,.: - i.�� ,� : I V: Vill - -41 IL --tAU t_- - j j--- 4-4 i ( t + v 1 III AT A-j lD�, � ' �ti3 - '- __ -►'fir.- - 1- -T- Us,=q4 KI - r--'- ! - --=-- -- �- --r -{ �t -•---- - I - - -I .._i- _ 1_ 1--' t j i _� .� j.. I i - �- � i _ i i Zj V `41 I -T T 171- x ;17 Aq I i J-1 -VI, ,L---4 T "2 -! 7z- 1-7 14A T-F t it t : II �- 1 '. `.' I trtCj,,'��\ I I � 1 i � � i 1 -' 1 I L IF— if I ---------------- In 7- Lop - A -1 19, ff __NN 77 IV 4 �al 167 07 L -, -- --��-=���c-moo-; 1�653�'/�; � �e�s � -�---- .- '�- � - � - - .- - - - �7 ou T-I- -OZCN7(� KIM_J :r-T 71- F-T ------------ -4- _ _;�/ ! !��-T-moi/ ;-'-ZJ -FT 1 - { / !L (TIA 01� *t ID _F_T 7 1:4T 1SQ1 it .. ............ TFTU 1 1 1 L_! fit M_ `_I 1 0 )7 -7, 4-1 ___L_ t I L MECAWind Version 2 . 1 . 0 . 5 per ASCE 7-05 Developed by MECA Enterprises, Inc. Copyright 2012 www.mecaenterprises.com Date 10/15/2012 Project No. : 12176 Company Name 2ENOVIC 6 ASSOCIATES, INC. Designed By SRH Address 301 EAST 6TH STREET, SUITE 1 Description 28x40 SFR City PORT ANGELES Customer Name PENINSULA HOUSING AUTHORITY State WA Proj Location CLALLAM COUNTY, WA File Location: X:\12176 HOUSING AUTHORITY\ENGR\Structual\SFR DESIGN B.wnd Detailed Wind Load Design (Method 2) per ASCE 7-05 Basic Wind Speed(V) = 100.00 mph Structure Type = Building Structural Category = II Exposure Category = C Natural Frequency = N/A Flexible Structure = No Importance Factor = 1.00 Kd Directional Factor = 0.85 Alpha = 9.50 Zg = 900.00 ft At = 0.11 Bt = 1.00 Am = 0.15 Bm = 0.65 Cc = 0.20 1 = 500.00 ft Epsilon = 0.20 Zmin = 15.00 ft Slope of Roof = 4 : 12 Slope of Roof(Theta) = 18.45 Deg Ht: Mean Roof Ht = 10.34 ft Type of Roof = Gabled RHt: Ridge Ht = 12. 67 ft Eht: Eave Height = 8.00 ft OH: Roof Overhang at Eave= .00 ft Roof Area = 1181.00 ft^ 2 Bldg Length Along Ridge = 40.00 ft Bldg Width Across Ridge= 28.00 ft Gust Factor Category I Rigid Structures - Simplified Method Gustl: For Rigid Structures (Nat. Freq.>l Hz) use 0.85 = 0.85 Gust Factor Category II Rigid Structures - Complete Analysis Zm: 0.6*Ht = 15.00 ft lzm: Cc* (33/Zm) ^0.167 = 0.23 Lzm: 1* (Zm/33) ^Epsilon = 427.06 ft Q: (1/ (1+0.63* ( (B+Ht) /Lzm) ^0.63) ) ^0.5 = 0.94 Gust2: 0. 925* ( (1+1.7*lzm*3.4*Q) / (1+1.7*3.4*lzm) ) = 0.89 Gust Factor Summary Not a Flexible Structure use the Lessor of Gustl or Gust2 = 0.85 Figure 6-5 Internal Pressure Coefficients for Buildings, GCpi GCPi : Internal Pressure Coefficient = +/-0.18 Figure 6-6 External Pressure Coefficients Cp - Loads on Main Wind-Force Resisting Systems(Method 2) heta h L z �. B B Kh: 2.01* (Ht/Zg) ^ (2/Alpha) = 0.85 Kht: Topographic Factor (Figure 6-4) = 1.00 Qh: .00256* (V) ^2*I*Kh*Kht*Kd = 18.47 psf Cpww: Windward Wall Cp(Ref Fig 6-6) = 0.80 Roof Area = 1181.00 ft^2 Reduction Factor based on Roof Area = 0.80 MWFRS-Wall Pressures for Wind Normal to 40 ft wall (Normal to Ridge) Wall Cp Pressure Pressure +GCpi (psf) GCpi (psf) --------------- ------ --------- - ----------- Leeward Wall -0.50 -11.18 -4.53 Side Walls -0.70 -14.32 -7.67 Wall Elev Kz Kzt qz Press Press Total Shear Moment t psf +GCpi -GCPi +/-GCPi Kip K-ft --------------------------------------- -------------------------- Windward 12.67 0.85 1.00 18.47 9.24 15.89 20.41 10.34 65.53 Note: 1) Total = Leeward GCPi + Windward GCPi 2) Shear and Moment are sum of forces (Leeward+Windard) acting on bldg walls. Note that the shear 6 moment don't consider loads on roof or end gable. Roof Location Cp +GCpi(psf) -GCpi(psf) --------------------- ------- ---------- ---------- Windward - Min Cp -0.42 -9.92 -3.27 Windward - Max Cp 0.05 -2.54 4.11 Leeward Perp to Ridge -0.57 -12.27 -5.62 Overhang Top (Windward) -0.42 -6.59 -6.59 Overhang Top (Leeward) -0.57 -8.95 -8.95 Overhang (Windward only) 0.80 12.56 12.56 MWFRS-Wall Pressures for Wind Normal to 28 ft wall (Along Ridge) Wall Cp Pressure Pressure +GCpi (psf) -GCpi (psf)