HomeMy WebLinkAbout1419 Pendley Court Address: 1419 Pendley Court PREPARED 3/03/15, 12:21:20 INSPECTIONTICKET PAGE 3 CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 3/03/15 ------------------------------------------------------------------------------------------------- ADDRESS . : 1419 PENDLEY CT SUBDIV: CONTRACTOR : PHONE OWNER SARAH SLOTA PHONE PARCEL 06-30-01-8-6-0120-0000- APPL NUMBER: 14-00000743 RES NEW SFR ----------------------------------------------—------------——--------------------------- PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT * RESULTS/COMMENTS --—-------------------------------—------—--------------------- -------------------- BL1 01 8/22/14 JLL BLDG FOUNDATION FOOTING 8/22/14 AP August 22, 2014 9:31:07 AM pbarthol. Bruce 912-0079 August 22, 2014 11:58:33 AM jlierly. DSD O1 9/12/14 JLL BLDG DOWN SPOUT DRAINS 9/12/14 AP September 12, 2014 12:19:34 PM pbarthol. - Bruce 912-0079 September 12, 2014 3:56:47 PM jlierly. BFF O1 9/19/14 JLL BLDG FLOOR FRAMING 9/19/14 AP September 19, 2014 8:37:48 AM pbarthol. Bruce 912-0079 September 19, 2014 4:23:24 PM jlierly. - BL9 01 10/24/14 JLL BLDG SHEARWALL 10/24/14 AP October 24, 2014 1:18:24 PM pbarthol. Bruce 912-0079 October 24, 2014 4:02:44 PM jlierly. BAIR O1 12/08/14 JLL BLDG AIR SEAL 12/09/14 AP December 8, 2014 9:13:34 AM pbarthol. Bruce 912-0079 December 9, 2014 9:20:47 AM jlierly. BL3 01 12/08/14 JLL BLDG FRAMING " 12/09/14 AP December 8, 2014 9:13:18 AM pbarthol. Bruce 912-0079 December 9, 2014 9:20:47 AM jlierly. _ BLI O1 12/11/14 PB BLDG INSULATION 12/11/14 AP December 11, 2014 8:54:05 AM pbarthol. December 12, 2014 9:34:14 AM pbarthol. FFNL O1 2/06/15 KDD FIRE FINAL 2/06/15 AP February 6, 2015 12:19:57 PM kdubuc. fire final February 6, 2015 12:20:19 PM kdubuc. fire final PW99 01 2/18/15 RV PUBLIC WORKS FINAL 2/18/15 AP February 23, 2015 1:42:38 PM rvess. February 23, 2015 1:43:01 PM rvess. BL99 01 2/19/15 JLL BLDG FINAL 2/20/15 DA February 19, 2015 9:11:31 AM pbarthol. February 20, 2015 4:53:05 PM pbarthol. impact protection for heat pump unit. Temp occupancy for 30 days issued, expires 3/19/2015 BL99 02 3/03/15 L BLDG FINAL March 3, 2015 11:24:20 AM pbarthol. Bollards in place -------------------------------------- COMMENTS AND NOTES ---------- CITY OF PORT ANGELES 321 E 5TH STREET P.O. BOX 1150 PORT ANGELES WA 98362 C E R T I F I C A T E O F O C C U P A N C Y T E M P O R A R Y Issue Date . . . . . . 2/19/15 Expiration Date . . . . 3/19/15 Parcel Number . . . . . 06-30-01-8-6-0120-0000- Property Address . . . 1419 PENDLEY CT PORT ANGELES WA 98363 Subdivision Name . . . Legal Description . . . PENDLEY ESTATES SUB LOT 12 VOL15 PG78 Property Zoning . . . . RS9 RESDNTL SINGLE FAMILY Owner . . . . . . . . . SARAH SLOTA Contractor . . . . . . O Application number 14-00000743 000 000 Description of Work RES NEW SFR Construction type . . . Occupancy type Flood Zone Special conditions February 19, 20 : 37 : 23 thol. Bollards plac to pro c ump it . Approved . . . . . . . it i g Official VOID UNLESS SIGNED BY BUILDING OFFICIAL CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY&ECONOMIC DEVELOPMENT- BUILDING DIVISION 321 EAST 5TH STREET, PORT ANGELES, WA 98362 V Application Number . . . . . 14-00000743 Date 7/16/14 Application pin number . . . 592701 Property Address . . . . . . 1419 PENDLEY CT ASSESSOR PARCEL NUMBER: 06-30-01-8-6-0120-0000- REPORT SALES TAX Application type description RES NEW SFR Subdivision Name . . . . . . On your state excise tax form Property Use . . . . . . . . to the City of Port Angeles Property Zoning . . . . . . . RS9 RESDNTL SINGLE FAMILY (Location Code 0502) Application valuation . . . . 114302 Application desc 1687 SQ FT SFR ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ SARAH SLOTA OWNER 2202 W 16TH St E6 PORT ANGELES WA 98363 \ ---------------------------------------------------------------------------- Permit . . . . BUILDING. PERMIT -RESIDENTIAL Additional desc . . 1687 SQ FR SFR Permit Fee . . . . 1104.25 Plan Check Fee 717.76 Q Issue Date . . . . 7/16/14 Valuation . . . . 114302 {� Expiration Date 1/12/15- Qty /12/15Qty Unit Charge Per Extension n BASE FEE 1020.25 1�`\ 15.00 5.6000 THOU BL-100,001-500K (5.60 PER K) 84.00 ---------------------------------------7------------------------------------ Permit . . . . . . MECHANICAL PERMIT Additional desc . . MECHANICAL SFR Permit Fee . . . . 141.60 Plan Check Fee .00 Issue Date . . . . 7/16/14 Valuation . . . . 0 Expiration Date . . 1/12/15 Qty Unit Charge Per Extension BASE FEE 50.00 1.00 14.8000 EA ME-FURN/HP/FAU < OR = 5 TON 14.80 3.00 7.2500 EA ME-VENT FAN (SINGLE DUCT) 21.75 1.00 10.6500 EA ME-HOOD/DUCT-MECH. EXHAUST 10.65 3.00 14.8000 EA ME-HEATER(SUSP/WALL/FLOOR-MTD) 44.40 ---------------------------------------------------------------------------- Permit . . . . . . PLUMBING PERMIT Additional desc . . PLUMBING SFR Permit Fee . . . . 142.00 Plan Check Fee .00 Issue Date 7/16/14 Valuation . . . . 0 Expiration Date 1/12/15 Qty Unit Charge Per Extension BASE FEE 50.00 6.00 7.0000 EA PL-PLUMBING TRAP 42.00 1.00 7.0000. EA PL-WATER LINE 7.00 3.00 7.0000 EA PL-DRAIN VENT PIPING 21.00 Separate Permits are required forelectrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does Q not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. G / Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder) T:Forms/Building Division/Building Permit BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS— Building Inspections 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION: Footings Stemwall Foundation Drainage/Downspouts Piers Post Holes(Pole Bldgs.) PLUMBING: Under Floor/Slab Rough-In Water Line Meter to Bldg) Gas Line Back Flow/Water FINAL Date Accepted b AIR SEAL: Walls Ceiling FRAMING: Joists/Girders/Under Floor Shear Wall/Hold Downs Walls/Roof/Ceiling Drywall Interior Braced Panel Only) T-Bar INSULATION: Slab Wall/Floor/Ceiling MECHANICAL. Heat Pum /Furnace/FAU/Ducts Rough-In Gas Line Wood Stove/Pellet/Chimney Commercial Hood/Ducts FINAL Date Accepted b MANUFACTURED HOMES: Footing/Slab Blocking&Hold Downs Skirting PLANNING DEPT. Separate Permit#s SEPA: Parking/Lighting ESA: Landscaping SHORELINE: . r( FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE Inspection Type Date Accepted By Electrical 417-4735 Construction- R.W. PW I Engineering 417-4831 Fire 417-4653 Planning 417-4750 Building 417-4815 T:Forms/Building Division/Building Permit CITY OF PORT ANGELES '" ® DEPARTMENT OF COMMUNITY&ECONOMIC DEVELOPMENT- BUILDING DIVISION 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Page 2 Application Number . . . . . 14-00000743 Date 7/16/14 Application pin number . . . 592701 REPORT SALES TAX Qty Unit Charge Per Extension 1.00 15.0000 EA PL-SEWER LINE 15.00 on your state excise tax form 1.00 7.0000 EA PL-WATER HEATER 7.00 to the City of Port Angeles --------------------------------------------------------------- Special Notes and Comments Location Code 0502) June 24, 2014 11:49:31 AM pbarthol. Plan check fees for permits 14-743 and 14-742 pain on permit 14-743. No plan review charged on 14-742 pb July 2, 2014 7:35:05 AM rbecker. You did not mark on your permit, if you were installing a fire or lawn sprinkler system. If you are installing either one, you will need to install a backflow assembly. If you havice any questions call Ron Becker at 360-417-4886, fax: 360-452-4972, or E-mail: rbecker@cityofpa.us Address numbers shall be plainly visible from the street. Address numbers shall be a minimum of six inches high and be of contrasting color from the background. A full acceptance test will be required for the fire sprinkler system. Call for cover inspection for .all sprinkler installations. All homes in new subdivisions that are outside of the Fire Department four-minute response area shall be equipped with residential fire sprinkler systems that comply with the International Fire Code (IFC) and National Fire Protection Association (NFPA) . July 9, 2014 8:57:30 AM sroberds. The permit allows for a new sfr in the RS-9 w/attached garage for total lot cov of 19$ and site cov of 415k. No land use issues anticipated. Electrical load calculations and electrical permits are required. Ditches & 12" culverts will be installed to City Stanards. See Public Works Engineering for Standards. All SWPPP elements must be followed as this is part of a larger plan of development (Pendley Ct) including: 3.1.1 Element #1 Mark Clearing Limits 3.1.2 Element 42 Establish Construction Access 3.1.3 Element #3 Control Flow Rates 3.1.4 Element #4 Install Sediment Controls 3.1.5 Element #5 Stabilize Soils 3.1.6 Element #6 Protect Slopes 3.1.7 Element #7 Protect Drain Inlets 3.1.8 Element #8 Stabilize Channels and Outlets 3.1.9 Element #9 Control Pollutants 3.1.10 Element #10 Control Dewatering 3.1.11 Element #11 Maintain BMPs 3.1.12 Element #12 Manage the Project Consider applying for the City Green Infrastructure Rebate of up to $750.00 towards the materials to install rain Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder) T:Forms/Building Division/Building Permit BUILDING PERMIT INSPECTION RECORD -- PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS— Building Inspections 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION: Footings Stemwall Foundation Drainage/Downspouts Piers Post Holes(Pole Bldgs.) PLUMBING: Under Floor/Slab Rough-In Water Line Meter to Bldg) Gas Line Back Flow/Water FINAL Date Accepted b AIR SEAL: Walls Ceiling FRAMING: Joists/Girders/Under Floor Shear Wall/Hold Downs Walls/Roof/Ceiling Drywall Interior Braced Panel Only) T-Bar INSULATION: Slab Wall/Floor/Ceiling MECHANICAL: Heat Pum /Furnace/FAU/Ducts Rough-In Gas Line Wood Stove/Pellet/Chimney Commercial Hood/Ducts FINAL Date Accepted b MANUFACTURED HOMES: Footing/Slab Blocking&Hold Downs Skirting PLANNING DEPT. Separate Permit#s SEPA: Parkin /Lighting ESA: Landscaping SHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE Inspection Type Date Accepted By Electrical 417-4735 Construction-R.W. PW I Engineering 417-4831 Fire 417-4653 Planning 417-4750 Building 417-4815 T:Forms/Building Division/Building Permit CITY OF PORT ANGELES . DEPARTMENT OF COMMUNITY&ECONOMIC DEVELOPMENT-BUILDING DIVISION ® 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Page 3 Application Number . . 14-00000743 Date 7/16/14 Application pin number . . . 592701 ---------------------------------------------------------------------------- REPORT SALES TAX Special Notes and Comments on your state excise tax form garden to control roof and driveway runoff. Also rebates available for downspout disconnections.Contact Jonathan to the City of Port Angeles Boehme at 360 11 (Location Code 0502) All constructionon work within the City right of way requires a separate Right of Way Construction application to be completed by the contractor and approved by Public Works Engineering prior to the start of work. A pedestrian or traffic control plan is to be submitted for 'approval with the application as necessary. Sanitary sewer connection inspection is required by Public Works prior to back fill of ditch. 24 hour advance notice is required. Public Works Inspection request line 417-4831 Trench safety per applicable laws. Temp erosion control and surface restoration responsibility of applicant. Contact City inspector prior to start of work @ 360 417-4831. No attachment to sanitary sewer.of stormwater roof leaders, foundation drains, yard drains, or any other CSO contribution is allowed. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . RES UNDERGRND SERVICE FEE 770.00 SEWER SYSTEM DELV CHARGE 2260.00 STATE SURCHARGE 4.50 PW WATER SYSTEM USE FEE 2260.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 1387.85 1387.85 .00 .00 Plan Check Total 717.76 717.76 .00 .00 Other Fee Total 5294.50 5294.50 .00 .00 Grand Total 7400.11 7400.11 .00 .00 Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder) T:Forms/Building Division/Building Permit BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS Building Inspections 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION: Footings Stemwall Foundation Drainage/Downspouts Piers Post Holes(Pole Bldgs.) PLUMBING: Under Floor/Slab Rough-in Water Line Meter to Bldg) Gas Line Back Flow/Water FINAL Date Accepted b AIR SEAL: Walls Ceiling FRAMING: Joists/Girders/Under Floor Shear Wall/Hold Downs Walls/Roof/Ceiling Drywall Interior Braced Panel Only) T-Bar INSULATION: Slab Wall/Floor/Ceiling MECHANICAL. Heat Pum /Furnace/FAU/Ducts Rough-in Gas Line Wood Stove/Pellet/Chimney Commercial Hood/Ducts FINAL Date Accepted b MANUFACTURED HOMES: Footing/Slab Blocking&Hold Downs Skirting PLANNING DEPT. Separate Permit#s SEPA: Parkin /Lighting ESA: Landscaping SHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE Inspection Type Date Accepted By Electrical 417-4735 Construction- R.W. PW I Engineering 417-4831 Fire 417-4653 Planning 417-4750 Building 417-4815 T:Forms/Building Division/Building Permit 0f PORT^"Q CITY OF PORT ANGELES PUBLIC WORKS & UTILITIES • 321 EAST 5TH STREET, PORT ANGELES,WA 98362 4ea Application Number . . . . . 14-00000743 Date 7/16/14 Application pin number . . . 592701 Property Address . . . . . . 1419 PENDLEY CT REPORT SALES TAX ASSESSOR PARCEL NUMBER: 06-30-01-8-6-0120-0000- on your state excise tax form Application type description RES NEW SFR Subdivision Name . . . . . . to the City of Port Angeles Property Use . . . . . . . . (Location Code 0502) Property Zoning . . . . . . . RS9 RESDNTL SINGLE FAMILY Application valuation . . . . 114302 ---------------------------------------------------------------------------- Application desc 1687 SQ FT SFR ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ SARAH SLOTA OWNER 2202 W 16TH St E6 PORT ANGELES WA 98363 ---------------------------------------------------------------------------- Permit . . . . . . DRIVEWAY INSTALLATION Additional desc . . DRIVEWAY AND CULVERT Permit Fee . . . . 180.00 Plan Check Fee .00 Issue Date 7/16/14 Valuation . . . . 0 Expiration Date 1/12/15 Qty Unit Charge Per Extension BASE FEE 180.00 ---------------------------------------------------------------------------- Permit . . . . . . PUBLIC WORKS RES WATER SERV Additional desc 3/411 DROP IN WATER METER Permit Fee . . . . 420.00 Plan Check Fee .00 Issue Date . . . . 7/16/14 Valuation . . . . 114302 Expiration Date . . 1/12/15 Qty Unit Charge Per Extension 1.00 420.0000 EA PW WATER METER DROP IN 420.00 ---------------------------------------------------------------------------- Permit . . . . . . SANITARY SEWER HOOK UP Additional desc . . Permit Fee . . . . 150.00 Plan Check Fee .00 Issue Date . . . . 7/16/14 Valuation . . . . 114302 Expiration Date . . 1/12/15 Qty Unit Charge Per Extension 1.00 150.0000 EA SAN SEWER HOOKUP 150.00 ---------------------------------------------------------------------------- Special Notes and Comments June 24, 2014 11:49:31 AM pbarthol. Plan check fees for permits 14-743 and 14-742 pain on permit 14-743. No plan review charged on 14-742 pb July 2, 2014 7:35:05 AM rbecker. You did not mark on your permit, if you were installing a Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements.This permit becomes null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned for a period of 180 days after the work as-commenced,or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. -7/1111 Signature of Contract Authorized Agent Date Signature of Owner(if owner is builder) Date T:\Policies\1102.15[10/08] PERMIT INSPECTION RECORD CALL 417-4831 FOR UTILITY INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED COMMENTS YES NO PW UTILITIES (Engineering Division) i WATERLINE/METER SEWER CONNECTION SANITARY STORM SITE DRAINAGE SITE EROSION CONTROL PARKING SIDEWALK CURB&GUTTER DRIVEWAY APPROACH BACK-FLOW DEVICE FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED YES NO CONSTRUCTION R.W./PW/ CONSTRUCTION-R.W. ENGINEERING 417-4831 PW/ENGINEERING FIRE 417-4653 FIRE DEPT. PLANNING DEPT. 417-4750 PLANNING DEPT. BUILDING 417-4815 BUILDING T:\Policies\1102.15[10/08] CITY OF PORT ANGELES PUBLIC WORKS & UTILITIES ,mss 321 EAST 5TH STREET, PORT ANGELES,WA 98362 Page 2 Application Number . . . . . 14-00000743 Date 7/16/14 Application pin number . . . 592701 REPORT SALES TAX ------------------ -------------------------------------------- Special Notes and Comments on your state excise tax form fire or lawn sprinkler system. If you are installing either to the City of Port Angeles one, you will need to install a backflow assembly. Location Code 0502) If you havice any questions call Ron Becker at 360-417-4886, fax: 360-452-4972, or E-mail: rbecker@cityofpa.us Address numbers shall be plainly visible from the street. Address numbers shall be a minimum of six inches high and be of contrasting color from the background. A full acceptance test will be required for the fire sprinkler system. Call for cover inspection for all sprinkler installations. All homes in new subdivisions that are outside of the Fire Department four-minute response area shall be equipped with residential fire sprinkler systems that comply with the International Fire Code (IFC) and National Fire Protection Association (NFPA) . July 9, 2014 8:57:30 AM sroberds. The permit allows for a new sfr in the RS-9 w/attached garage for total lot cov of 19% and site cov of 41%. No land use issues anticipated. Electrical load calculations and electrical permits are required. Ditches & 12" culverts will be installed to City Stanards. See Public Works Engineering for Standards. All SWPPP elements must be followed as this is part of a larger plan of development (Pendley Ct) including: 3.1.1 Element #1 Mark Clearing Limits 3.1.2 Element #2 Establish Construction Access 3.1.3 Element #3 Control Flow Rates 3.1.4 Element #4 Install Sediment Controls 3.1.5 Element #5 Stabilize Soils 3.1.6 Element #6 Protect Slopes 3.1.7 Element #7 Protect Drain Inlets 3.1.8 Element #8 Stabilize Channels and Outlets 3.1.9 Element #9 Control Pollutants 3.1.10 Element #10 Control Dewatering 3.1.11 Element #11 Maintain BMPs 3.1.12 Element #12 Manage the Project Consider applying for the City Green Infrastructure Rebate of up to $750.00 towards the materials to install rain garden to control roof and driveway runoff. Also rebates available for downspout disconnections.Contact Jonathan Boehme at 360 417-4811 All construction work within the City right of way requires a separate Right of Way Construction application to be completed by the contractor and approved by Public Works Engineering prior to the start of work. A pedestrian or traffic control plan is to be submitted for approval with the application as necessary. Sanitary sewer connection inspection is required by Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned for a period of 180 days after the work as.commenced,or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Signature of Contractor or Authorized Agent Date Signature of Owner(if owner is builder) Date T:\Policies\1102.15[10/081 PERMIT INSPECTION RECORD CALL 417-4831 FOR UTILITY INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER,M INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INA CONSPICUOUS LOCATION. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED COMMENTS YES NO PW UTILITIES (Engineering Division) WATERLINE/METER SEWER CONNECTION SANITARY STORM SITE DRAINAGE SITE EROSION CONTROL PARKING SIDEWALK CURB&GUTTER DRIVEWAY APPROACH BACK-FLOW DEVICE FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED YES NO CONSTRUCTION R.W./PW/ CONSTRUCTION-R.W. ENGINEERING 417-4831 PW/ENGINEERING FIRE 417-4653 FIRE DEPT. PLANNING DEPT, 417-4750 PLANNING DEPT. BUILDING 4174815 BUILDING T:Tolicies\1102.15(10/081 �pOflT,N,C CITY OF PORT ANGELES PUBLIC WORKS & UTILITIES 321 EAST 5TH STREET, PORT ANGELES,WA 98362 Page 3 Application Number . . . . . 14-00000743 Date 7/16/14 Application pin number . . . 592701 REPORT SALES TAX ------and----Comments-------- Special Notes --------------------------------------------- on your state excise tax form Public Works prior to back fill of ditch. 24 hour advance to the City of Port Angeles notice is required. Public Works Inspection request line (Location Code 0502). 417-4831 Trench safety per applicable laws. Temp erosion control and surface restoration responsibility of applicant. Contact City inspector prior to start of work @ 360 417-4831. No attachment to sanitary sewer of stormwater roof leaders, foundation drains, yard drains, or any other CSO contribution is allowed. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . RES UNDERGRND SERVICE FEE 770.00 SEWER SYSTEM DELV CHARGE 2260.00 STATE SURCHARGE 4.50 PW WATER SYSTEM USE FEE 2260.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 750.00 750.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 5294.50 5294.50 .00 .00 Grand Total 6044.50 6044.50 .00 .00 Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements.This permit becomes null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned for a period of 180 days after the work as.commenced,or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Signature of Contractor or Authorized Agent Date Signature of Owner(if owner is builder) Date T:\Policies\1102.15[10/08] PERMIT INSPECTION RECORD CALL 417-4831 FOR UTILITY INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. ITIS UNLAWFUL TO COVER, ~ INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INA CONSPICUOUS LOCATION. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED COMMENTS YES NO PW UTILITIES (Engineering Division) t WATERLINE/METER SEWER CONNECTION SANITARY STORM SITE DRAINAGE SITE EROSION CONTROL PARKING SIDEWALK CURB&GUTTER DRIVEWAY APPROACH BACK-FLOW DEVICE FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED YES NO CONSTRUCTION R.W./PW/ CONSTRUCTION-R.W. ENGINEERING 417-4831 PW/ENGINEERING FIRE 417-4653 FIRE DEPT. PLANNING DEPT. 417-4750 PLANNING DEPT. BUILDING 417-4815 BUILDING TAPolicies\1102.15[10/08] Tw,,E CITY dF €V x.T� 11]Ew For Cit Use Y Permit# W A S H I N G T 0 N , U . S . Date Received: 321 East 51' Street Port Angeles, WA 98362 Date Approved P: 360-417-4817 F: 360-417-4711 permits@cityofpa.us U 9� Building Permit Application Project Address: cc'v MainContact: ��5 i 2����o� s�� +��s ��Z Phone # 7!)6.0— �l a— o c>?� !°ter r✓s V1_4 /"'tovs(,✓W lqurH-� le(T7` E-Mail: Property Name Phone Owner !i -:3t/'e, - Mailing Address Email 2z�z �✓gsT G�f �� City State Zip - n R� nlG Ez�s L✓ 83� 3 y Contractor Name Phone Mailing Address Email City State Zip Contractor License# Expiration: Project Value: Zoning: Tax Parcel # Lot# $ //y 3-a _ / ,2 Type of Residential Commercial ❑ Industrial ❑ Public ❑ Permit Demolition ❑ Fire ❑ Repair ❑ Reroof(tear off/lay over) ❑ For the following,fill out both pages of permit application: New Construction 9'__ Remodel ❑ Addition ❑ Tenant Improvement ❑ Mechanical ❑ Plumbing ❑ Other. ❑ Existing Fire Sprinkler System? Maximum height of structure Proposed Bedrooms Proposed Bathrooms Yes ❑ No ❑ Project Description I have read and completed the application and know it to be true and correct.I am authorized to apply for this permit. I understand that it is my responsibility to determine what permits are required and to obtain permits prior to working on projects. I understand that the plan review fee is not refundable after plan review has occurred. I understand that I will forfeit the review fee if I cancel or withdraw the application before the permit is issued. I understand that if the permit is not issued within 180 days of receipt,the application will be considered abandoned and the fees forfeit. Date Print Name Signature 7/16/1 Y & UC �_ I-P7 c ar-%' Residential Structures �— For Office Use Area Description(SQ FT) Existing Proposed $$value Basement First Floor 1o/ U0 Second Floor.. Covered'Deck/Porch/Entry -3 Y�Z Deck .9 Garage 3 7j Carport Other(describe) Area Totals /697 Commercial Structures For Office Use Area Descriptions (SQ FT) Existing Proposed $$Value Existing-Structure(s) Proposed Addition Tenant Improvement? Other work(describe) Area Totals Lot/Site Coverage Calculations Footprint(SQ FT) of all Structures: Lot Size: %Lot Coverage L/,8 7 900 7 /9, 7 SQ FT Site coverage(all impervious+ %Site Coverage structures) 1/0, Mechanical Fixtures Indicate how many of each type of fixture to be installed or relocated as part of this project. Air Handler Size: # Haz/Non-Haz Piping #of Outlets: Appliance Vent # Heater(Suspended,Floor,Recessed wall) # 3 Boiler/Compressor Size: # Heating/Cooling appliance # repair/alteration Evaporative Cooler(attached,not # Pellet Stove/Wood-burning/Gas # portable) Fireplace Gas Stove Gas Cook Stove/Misc. Fuel Gas Piping #of Outlets: Ventilation Fan,single duct # . 3 Furnace Heat Pu Size: # Ventilation System # Forced Air nit Plumbing Fixtures Indicate how many of each type of fixture to be installed or relocated Plumbing Traps # Fuel gas piping #of Outlets: Water Heater # Medical gas piping #of Outlets: Water Line # Vent piping # Sewer Line # / Industrial waste pretreatment # interceptor Other describe T:\BUILDING\APPLICATION FORMS\BUILDING PERMIT 081212.DOCX OF PORT'J'%,�1 .r PRESCRIPTIVE APPROACH-SIMPLE FORM For the Washington State Energy Code(WSEC) 2009 Edition. Climate.Zone 1 MY GOVERNMENT Site Information: - Building Department Use Only: Lot: *T-1 a / Pew DL gy %Permit # Address: j y/ /9&n/,DLey coy r� Notes: City: r0 9--f ygid State: &/e Zip: Contact: `- Phone: 360 - 007 f Phone 2: 360- FAX: 60-FAX: WSEC Table 6-1 PRESCRIPTIVE REQUIREMENTS FOR SINGLE-FAMILY RESIDENTIAL OR DUPLEX CLIMATE ZONE 1 (Unlimited Glazing Option Only) Glaiing ,, Glazing U Factor x Door �� � Vaulted fntenor Wall -Wall Exterior Option', Area%of _ U -Ceiling Abovfe Floor Slab on- FloorVertical ' ;O`verhead Factor , ` 'Ceiling GPade Belovtr� Below Concrete. R-49 III or R-21 R-21 R-30/ R-10 Unlimited 0.30 0.50 0.20 R-38 R-38 int T13 R-10 U=0.029 2' adv This Project complies with the following: The project is a single-family residence or duplex. The project is a wood frame OR all of the insulation is interior or exterior of the framing. All building components meet the requirements listed above. The project will meet all other provisions of the WSEC and VIAQ. The Project will take advantage of the following exceptions to the prescriptive option. ❑ 602.6 Exception 2. One unlabeled or untested exterior swinging door, 24 sq.ft. or less, may be installed per unit for ornamental, security, or architectural purposes. Location of the door taking this exception: ❑ 602.6 Exception 2. If a door is mostly glass, it should meet the requirement of the vertical glazing U-factor listed above. Location of the door(s)taking exception: . 1— Type of Heat Source: Dyef-J_2_5s 1J- 10yn_P 3 o„isan 5W ws T:Forms/Building Division/Prescriptive Approach-Simple Form cp.,v�c Electrical Information Form e Public Works&Utilities Department(360)417-4700 City Electrical Inspector(360)417-4735 Please complete and return to Public Works&Utilities Department 3k • • • • Permanent service: Name: Name and address of party Street: responsible for permanent City I State I ZIP: service billing? Daytime Phone: Home Phone: FRIMIQQ9,M711111111 (if other than above) Site contact: Name: ✓2c.��� /'rjcCoPP J Title: CDA)Sl— 5 V��?vispYL d/9 , Daytime Phone: '.3G p1a - 0o7 Contractor: Name: Company: Daytime Phone: Electrician: Name: Company: Daytime Phone: Excavator: Name: Company: Daytime Phone: ' ❑Existing ew ingle-family residence ❑M Iti-family residence;#of units ❑Commercial L7Subdivision; #of lots 0 ❑Overhead service El General service E service ❑Other: • • • • Description of work: r.�-✓ Street address/lot number. /(- / f' f+✓(7� Co a , uSOT Nearest cross street: t,)i;5 �/ n> , Desired connection date: Electrical transformer serving property is: ❑on a pole on the ground Total square footage: $7 sq.ft. Main disconnect size: v amps Voltage: 20/240 1ph ❑120/208 3ph ❑277/480 3ph ❑120/240 3ph ❑480 3W 3ph ❑ Other Standard residential loads(Lighting, refrigerator, dishwasher,washer) Check all that apply: ❑,A/C (_ton) MR-ange/Oven ❑Hot Tub L'�C,othes Dryer [�Heating ❑Pumps �Hp) ❑No Load Change (Water Heater ❑Elevator C_Hp) ❑Other • ' • • Please provide a copy of the following: 'Detailed plot plan (.dwg or.dxf format mandatory for subdivisions). 'Electrical one-line drawing showing the service entrance panel and location. 'Connected load data. 'Size and locked rotor amps of all motors over 50hp. Applicant's Signature: Date: MAIL OR DELIVER COMPLETED FORM TO: 321 E 5TH STREET; PORT ANGELES, WA 98362 FAX TO: 360-417-4711 WS Information for^.;.xls WF N:''r'WKS1IGHT`.rNGR\?l G Lr 77 HM�el _ ...._......... -- Qj J to Plan r=20.0' t*4olzlu PORT ANC,`EI. b.SVA 98363 couNTY of cLALL4m PENDL[---Y COUIZT LOT 12 LOT COVCR64C. 1687/9007F 18.79 51TE COVERAGE 3669/9007F = ,40.7% LIOUSE.STYLE:Tflr- NuL-5 cqj 10,20' _....... - 'Z31`. DIOF I X40' os 77 a` i I 33' 149-I" I y t 45V 4'26- 1S' KIP,t1p bite Ilan r=20.0 I�� lF�L�GoUf�'"' NoRl11 � PORT ANGELL6.VA 98363 couNTY OF CLALLAM PC NDLEY COUIZT LOT 12 LOT CO\/I=RAG'[ 1687/9007F- 18.796 6ITL COVEI24G'E 3669/9007F= 40.7% i lOUSE bTYLE:Tfl['NEIL-6` : } 1.7 , um l' VM AS ol alN -- - -- r- - � Z T— ; T — U � � -- -- - -- - - -- -- - � I T , I I , a : Gn i -- — — I : : t , t I � t t : : : - , : i � I , ! 1 1 K4 --- - - - -- -- - -' - - - - - - r 1 ; ' I i V� � X ti4 `7-`scI -- —, -- - i , _ - - --rill , i — F vckti ' -- — (= - 's , _77-001-yo, yAl, U � ;i/ZI SaoSw , i , s " y r ! i 1-0-7- ---------- ST , - i _ t �Nc- -1 -7 U6--t ----------- -------------4 --------------- 7 V 1124 T 1 1 "17 ---------- 41-4- -4j, LlIv ---------- ------------- �- 'Ute ' �- C�`� �`�tx_ ��� �1 f (� '' �� Ic- j ' I i � r _ t ZLO car = 1 8 ,� T _ 71 _ 7111 44 L Sip l r I : - - -- ' `(per C�r'v�- . ( � �C C17`f 1 ' 53 _ t t ( Z ---- -' -� 17 �X Ly! i : I , r I 1 1ST ! YT -1 ZN : - I I + f I 1.. I r : 2p - I I 1 7T -- I-OiY ( j- -- --- 8Ac�-+-` '6n1S — 3Zd : I - , , __ - __ I : , CCS [ I - - - -- ' A--17 Y i _ I - ----------- -- - - , 1 III i" , -- - - -- - : Off' (--z-L S-Z - Z�z� �� = �� b - 1 s - - - � ` : - -- - - T Z T161- : IU : : : � T 1 - '� - : �f : L fff .� 1. �✓l%�'r�` MECAWind Version 2 . 1 . 0 . 5 per ASCE 7-05 Developed by MECA Enterprises, Inc. Copyright 2012 www.mecaenterprises.com Date 10/11/2012 Project No. 12176 Company Name ZENOVIC 6 ASSOCIATES, INC. Designed By SRH Address 301 EAST 6TH STREET, SUITE 1 Description : 28x40 SFR City PORT ANGELES Customer Name PENINSULA HOUSING AUTHORITY State WA Proj Location CLALLAM COUNTY, WA File Location: X:\12176 HOUSING AUTHORITY\ENGR\Structual\28x40 SFR.wnd Detailed Wind Load Design(Method 2) per ASCE 7-05 Basic Wind Speed(V) = 100.00 mph Structure Type = Building Structural Category = II Exposure Category = C Natural Frequency = N/A Flexible Structure = No Importance Factor = 1.00 Kd Directional Factor = 0.85 Alpha = 9.50 Zg = 900.00 ft At = 0.11 Bt = 1.00 Am = 0.15 Bm = 0.65 Cc = 0.20 1 = 500.00 ft Epsilon = 0.20 Zmin = 15.00 ft Slope of Roof = 4 : 12 Slope of Roof(Theta) = 18.45 Deg Ht: Mean Roof Ht = 10.34 ft Type of Roof = Gabled RHt: Ridge Ht = 12.67 ft Eht: Eave Height = 8.00 ft OH: Roof Overhang at Eave= .00 ft Roof Area = 1181.00 ft^ 2 Bldg Length Along Ridge = 40.00 ft Bldg Width Across Ridge= 28.00 ft Gust Factor Category I Rigid Structures - Simplified Method Gustl: For Rigid Structures (Nat. Freq.>l Hz) use 0.85 = 0.85 Gust Factor Category II Rigid Structures - Complete Analysis Zm: 0.6*Ht = 15.00 ft lzm: Cc* (33/Zm)^0.167 = 0.23 Lzm: 1* (Zm/33)^Epsilon 427.06 ft Q: (1/(1+0.63* ( (B+Ht) /Lzm) ^0.63) ) ^0.5 - 0. 94 Gust2: 0.925* ( (1+1.7*lzm*3.4*Q) /(1+1.7*3.4*lzm) ) = 0.89 Gust Factor Summary Not a Flexible Structure use the Lessor of Gustl or Gust2 = 0.85 Figure 6-5 Internal Pressure Coefficients for Buildings, GCpi GCPi : Internal Pressure Coefficient = +/-0.18 Figure 6-6 External Pressure Coefficients Cp - Loads on Main Wind-Force Resisting Systems(Method 2) eta h fig L z Id _� B B Kh: 2.01* (Ht/Zg) ^(2/Alpha) = 0.85 Kht: Topographic Factor (Figure 6-4) = 1.00 Qh: .00256* (V)^2*I*Kh*Kht*Kd = 18.47 psf Cpww: Windward Wall Cp(Ref Fig 6-6) = 0.80 Roof Area = 1181.00 ft^2 Reduction Factor based on Roof Area = 0.80 MWFRS-Wall Pressures for Wind Normal to 40 ft wall (Normal to Ridge) Wall Cp Pressure Pressure +GCpi (psf) -GCPi (psf) --------------- ------ ----------- ----------- Leeward Wall -0.50 -11.18 -4.53 Side Walls -0.70 -14.32 -7.67 Wall Elev Kz Kzt qz Press Press Total Shear Moment ft psf +GCpi -GCPi +/-GCPi Kip K-ft -------------------------------------------------------------------------------- Windward 12.67 0.85 1.00 18.47 9.24 15.89 20.41 10.34 65.53 Note: 1) Total = Leeward GCPi + Windward GCPi 2) Shear and Moment are sum of forces (Leeward+Windard) acting on bldg walls. Note that the shear & moment don't consider loads on roof or end gable. Roof Location Cp +GCpi(psf) -GCpi(psf) ----------------------- ------- ---------- ---------- Windward - Min Cp -0.42 -9.92 -3.27 Windward - Max Cp 0.05 -2.54 4.11 Leeward Perp to Ridge -0.57 -12.27 -5.62 Overhang Top (Windward) -0.42 -6.59 -6.59 Overhang Top (Leeward) -0.57 -8.95 -8.95 Overhang (Windward only) 0.80 12.56 12.56 MWFRS-Wall Pressures for Wind Normal to 28 ft wall (Along Ridge) Wall Cp Pressure Pressure +GCpi (psf) -GCpi (psf) s --------------- ------ ----------- ----------- Leeward Wall -0.41 -9.83 -3.18 Side Walls -0.70 -14.32 -7.67 Wall Elev Kz Kzt qz Press Press Total Shear Moment ft psf +GCpi -GCpi +/-GCpi Kip K-ft -------------------------------------------------------------------------------- Windward 12.67 0.85 1.00 18.47 9.24 15.89 19.07 6.76 42.85 Note: 1) Total = Leeward GCPi + Windward GCPi 2) Shear and Moment are sum of forces (Leeward+Windard) acting on bldg walls. Note that the shear & moment don't consider loads on roof or end gable. Roof - Dist from Windward Edge Cp Pressure Pressure +GCpi(psf) -GCpi(psf) --------------------------------- ------ ---------- ---------- 0.0 ft to 5.2 ft -0.90 -17.46 -10.81 5.2 ft to 10.3 ft -0.90 -17.46 -10.81 10.3 ft to 20.7 ft -0.50 -11.18 -4.53 20.7 ft to 40.0 ft -0.30 -8.04 -1.39