Loading...
HomeMy WebLinkAbout1612 Maloney Court Address: 1612 Maloney Court PREPARED 2/24/15, 13:37:36 INSPECTION TICKET PAGE 1 CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 2/24/15 ------------- -------—------ ADDRESS . : 1612 MALONEY CT SUBDIV: CONTRACTOR : PHONE OWNER HABITAT FOR HUMANITY CL COUNTY PHONE PARCEL 06-30-01-8-5-0030-0000- APPL NUMBER: 13-00001352 RES NEW SFR ------------------------------------------------------------------------------------------------ PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED ' RESULT RESULTS/COMMENTS -------------------—--------------------—----------------------------------------------—---- BL1 01 1/23/14 JLL BLDG FOUNDATION FOOTING 1/23/14 AP January 23, 2014 8:30:27 AM pbarthol. Dana 460-2485 +++++++++++++++ AM ++++++++++++++++++++ January 23, 2014 9:52:40 AM jlierly. 20 ufr installed /jll BL2 01 1/28/14 JLL BLDG FOUNDATION STEM WALL 1/28/14 AP January 28, 2014 8:20:05 AM pbarthol. Dana 460-2485 +++++++++++++++++ AM ++++++++++++++++++++ January 28, 2014 3:49:32 PM jlierly. BLFD 01 5/28/14 JLL BLDG FOUNDATION DRAINAGE 5/29/14 AP May 27, 2014 8:46:44 AM jlierly. May 27, 2014 3:16:51 PM jlierly. May 29, 2014 8:10:55 AM jlierly. BLIS 01 6/23/14 JLL BLDG INSULATION/SLAB 6/23/14 AP June 23, 2014 8:56:37 AM pbarthol. Harry 808-0049 June 23, 2014 4:06:27 PM jlierly. BL9 01 9/02/14 JLL BLDG SHEARWALL 9/02/14 AP September 2, 2014 9:30:02 AM pbarthol. Harry 808-0049 September 2, 2014 4:15:00 PM jlierly. BAIR 01 11/04/14 JLL BLDG AIR SEAL 11/04/14 AP November 4, 2014 9:35:02 AM jlierly. November 4, 2014 4:17:11 PM jlierly. BL3 01 11/04/14 JLL BLDG FRAMING 11/04/14 AP November 4, 2014 9:35:20 AM jlierly. November 4, 2014 4:17:11 PM jlierly. BLI 01 11/12/14 JLL BLDG INSULATION 11/12/14 AP November 12, 2014 10:38:06 AM pbarthol. Harry 808-0049 November 12, 2014 3:55:07 PM jlierly. PW99 01 2/23/15 RV PUBLIC WORKS FINAL 2/24/15 AP February 24, 2015 12:51:58 PM rvess. February 24, 2015 12:52:32 PM rvess. BL99 01 2/24/15 BLDG FINAL February 24, 2015 9:43:14 AM pbarthol. Harry 808-0049 PERMIT: ME 00 MECHANICAL PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------- ----- ME1 01 11/04/14 JLL MECHANICAL ROUGH-IN 11/04/14 AP November 4, 2014 9:35:53 AM jlierly. ----------------------------------- CONTINUED ONTO NEXT PAGE ----------------------------------- PREPARED 2/24/15, 13:37:36 INSPECTION TICKET PAGE 2 CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 2/24/15 ---------—------------—----- ADDRESS . : 1612 MALONEY CT SUBDIV: CONTRACTOR : PHONE OWNER HABITAT FOR HUMANITY CL COUNTY PHONE PARCEL 06-30-01-8-5-0030-0000- APPL NUMBER: 13-00001352 RES NEW SFR ------------------------------------------------------------------------------------------------ REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ---------------------------------—----------—-------—------—- November 4, 2014 4:17:11 PM jlierly. ME99 01 2/24/15 MECHANICAL FINAL February 24, 2015 9:43:32 AM pbarthol. Harry 808-0049 PERMIT: PL 00 PLUMBING RMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------- ----- PL1 01 5/28/14 JLL PLUMBING UNDER SLAB 5/29/14 DA May 28, 2014 9:02:37 AM jlierly. May 29, 2014 8:11:08 AM jlierly. Remove rocks and sand bed DWV per code/jll PL6 01 5/28/14 JLL PLUMBING WATER SUPPLY 5/29/14 AP May 27, 2014 8:45:39 AM jlierly. harry 808-0049 May 27, 2014 3:17:03 PM jlierly. May 29, 2014 8:11:38 AM jlierly. PL1 02 6/02/14 JLL PLUMBING UNDER SLAB 6/02/14 AP June 2, 2014 9:12:23 AM pbarthol. HARRY 808-0049 June 2, 2014 4:21:28 PM jlierly. PL2 01 11/04/14 JLL PLUMBING ROUGH-IN 11/04/14 AP November 4, 2014 9:35:33 AM jlierly. November 4, 2014 4:17:11 PM jlierly. PL99 01 2/24/15 JRf PLUMBING FINAL February 24, 2015 9:45:02 AM pbarthol. Harry 808-0049 ----------------- ------ COMMENTS AND NOTES -------------------------------------- CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY& ECONOMIC DEVELOPMENT- BUILDING DIVISION 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Application Number . . . . . 13-00001352 Date 12/17/13 Application pin number . . . 588472 Property Address . . . . . . 1612 MALONEY CT �\ ASSESSOR PARCEL NUMBER: 06-30-01-8-5-0030-0000- REPORT SALES TAX N Application type description RES NEW SFR on your state excise tax form I Subdivision Name . . . . . . Property Use . . . . . . . . to the City of Pod Angeles Property Zoning . . . . . . . RESIDENTIAL MEDIUM DENSTY (Location Code. 0502) Application valuation . . . . 103140 ---------------------------------------------------------------------------- Application desc res new sf ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ HABITAT FOR HUMANITY CL COUNTY OWNER 3430 HWT 101 E STE #32 PORT ANGELES, WA. PORT ANGELES WA 98362: --- Structure Information 000 000 NEW SFR --- Other struct info . . . . . TOTAL a LOT COVERAGE 40.00 CONSTRUCTION TYPE vn FIRE SPRINKLERS REQUIRED yes NUMBER OF STORIES 1..00 LOT SIZE 4500.00 PROPOSED LOT COVERAGE 1295.00 NUMBER OF UNITS 1.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT -RESIDENTIAL Additional desc . Permit Fee . . . . 1042.65 Plan Check Fee 677.72 Issue Date . . . . 12/17/13 Valuation . . . . 103140 Expiration Date 6/15/14 Qty Unit Charge Per Extension 'BASE FEE 1020.25 4.00 5.6000 THOU BL-100,001-500K (5'.��60 PER K) 22.40 ---------------------------------------------------------------------------- Permit . . . MECHANICAL PERMIT Additional desc SFR Permit Fee . . . . 181.85 Plan Check Fee .00 Issue Date . . . . 12/17/13 Valuation . . . . 0 Expiration Date 6/15/14 Qty Unit Charge Per Extension BASE FEE 50.00 1.00 14.8000 EA ME-FURN/HP/FAU < OR = 5 TON 14.80 3.00 7.2500 EA ME-VENT FAN (SINGLE DUCT) 21.75 1.00 10.6500 EA ME-VENT SYSTEM (NON-HVAC) 10.65 1.00 10.6500 EA ME-HOOD/DUCT-MECH. EXHAUST 10.65 5.00 14.8000 EA ME-HEATER(SUSP/WALL/FLOOR-MTD) 74.00 ----------------------------------------------------------------------------- Permit . . . . . . PLUMBING PERMIT Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is.not commenced within 180 days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced,or if required:inspectidns have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. KA aV-lVy;43;� j _� W Date Print Name Signature of Contract r or Authorized Agent Signature of Owner(if owner is builder) T:Forms/Building Division/Building Permit BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS— Building Inspections 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL.TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION: footings Stemwall Foundation Drainage/Downspouts Piers Post Holes(Pole Bldgs.) PLUMBING: Under Floor/Slab Rough-In Water Line(Meter to Bldg) Gas Line Back Flow/Water FINAL Date Accepted b AIR SEAL: Walls Ceiling FRAMING: Joists/Girders/Under Floor Shear Wall/Hold Downs Walls/Roof/Ceiling Drywall Interior Braced Panel Only) T-Bar INSULATION: Slab Wall/Floor/Ceiling MECHANICAL: Heat Pum /Furnace/FAU/Ducts Rough-in Gas Line Wood Stove/Pellet/Chimney Commercial Hood/Ducts FINAL Date Accepted b MANUFACTURED HOMES: Footing/Slab Blocking&Hold Downs Skirting PLANNING DEPT. Separate Permit#s SEPA: Parkin /Lighting ESA: Landscaping SHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE Inspection Type Date Accepted By Electrical 417-4735 Construction- R.W. PW /Engineering 417-4831 Fire 417-4653 Planning 417-4750 Building 417-4815 T:Forms/Building Division/Building Permit CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY& ECONOMIC DEVELOPMENT- BUILDING DIVISION ._ 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Page 2 Application Number . . . . . 13-00001352 Date 12/17/13 Application pin number . . . 588472 Additional desc . . SFR REPORT SALES TAX Permit Fee . . . . 142.00 Plan Check Fee . .00 on your state excise tax form Issue Date . . . . 12/17/13 Valuation . . . . 0 Expiration Date . . 6/15/14 to the City of Port Angeles Qty Unit Charge Per Extension (Location Code 0502) BASE FEE 50.00 6.00 7.0000 EA PL-PLUMBING TRAP 42.00 1.00 7.0000 EA PL-WATER LINE 7.00 3.00 7.0000 EA PL-DRAIN VENT PIPING 21.00 1.00 15.0000 EA PL-SEWER LINE 15.00 1.00 7..0000 EA PL-WATER HEATER 7.00 ---------------------------------------------------------------------------- Special Notes and Comments November 22, 2013 7:53:29 AM rbecker. Is the fire sprinkler system a closed system, which requires a double check valve assembly backflow? Or is the fire system an open system(vent to tolet) , which does not need a backflow? If you have any questions call Ron Becker at 417-4886,Fax:452-4972, or E-mail:rbecker@cityofpa.us Address numbers shall be plainly visible from the street. Address numbers shall be a minimum of six inches high and be of contrasting color from the background. All homes in new subdivisions that are outside of the Fire Department four-minute response area shall be equipped with residential fire sprinkler systems that comply with the International Fire Code (IFC) and National Fire Protection Association (NFPA) . December 10, 2013 10:27:39 AM sroberds. The application will result in a new sfr in the RMD for total lot cov of 28. and site cov of 40t. Reduced north side setback is 617" (3" modification) per a minor modification permitted per Section 17.45.040 PAMC. The development is done under an IOZ approved for the parent site; the adjustment is due to an oversight by the developer in site planning. Electrical load calculations and electrical permits are required. Consider applying for the City Green Infrastructure Rebate of up to $500.00 towards the materials to install rain garden to control roof and driveway runoff. Contact Jonathan Boehme at 360 417-4811 Trench safety per applicable laws. Temp erosion control and surface restoration responsibility of applicant. Contact City inspector prior to start of work @ 360 417-4831. No attachment to sanitary sewer of stormwater roof leaders, foundation drains, yard drains, or any other CSO contribution is allowed. All connections to City storm drain facilities require an inspection by Public-Works and Utilities Engineering prior cover. Contact inspection hot line 48 hours in advance of Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within,180.days,if construction,or work.is suspended or abandoned for a period of 180 days after the work has commenced, or if required-inspections have not been.requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder) T:Fcrms/Building Division/Building Permit r , BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS-- Building Inspections. 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION: Footings Stemwall Foundation Drainage/Downspouts Piers Post Holes(Pole Bldgs.) PLUMBING: Under Floor/Slab Rough-In Water Line(Meter to Bldg) Gas Line Back Flow/Water FINAL Date Accepted b AIR SEAL: Walls Ceiling FRAMING: Joists/Girders/Under Floor Shear Wall/Hold Downs Walls/Roof/Ceiling Drywall Interior Braced Panel Only) T-Bar INSULATION: Slab Wall/Floor/Ceiling MECHANICAL: Heat Pum /Furnace/FAU/Ducts Rough-in Gas Line Wood Stove/Pellet/Chimney Commercial Hood/Ducts FINAL Date Accepted b MANUFACTURED HOMES: Footin /Slab 113locking&Hold Downs Skirting PLANNING DEPT. Separate Permit#s SEPA: Parking/Lighting ESA: Landscaping SHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE Inspection Type Date Accepted By Electrical 417-4735 Construction-R.W. PW I Engineering 417-4831 Fire 417-4653 Planning 417-4750 Building 417-4815 T:Forms/Building Division/Building Permit CITY OF PORT ANGELES . DEPARTMENT OF COMMUNITY& ECONOMIC DEVELOPMENT- BUILDING DIVISION 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Page 3 Application Number . . . . . 13-00001352 Date 12/17/13 Application pin number . . . 588472 ---------------------------------- REPORT SALES TAX Special Notes and Comments on your state excise tax form commencing work @ 360 417-4831 Sanitary sewer connection inspection is required by to the City of Port Angeles Public Works prior to back fill of ditch. 24 hour advance (Location Code 0502) notice is required. Public Works Inspection request line 417-4831 ---------------------------------------------------------------------------- Other Fees . . . . . . RES UNDERGRND SERVICE FEE 770.00 SEWER SYSTEM DELV CHARGE 2260.00 STATE SURCHARGE 4.50 PW WATER SYSTEM USE FEE 2260.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 1366.50 1366.50 .00 .00 Plan Check Total 677.72 677.72 .00 .00 Other Fee Total 5294.50 5294.50 .00 .00 Grand Total 7338.72 7338.72 .00 .00 Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days,if construction,or work is suspended or abandoned for a period of 180 days after the work has commenced, or if required:inspectidns have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder) T:Forns/Building Division/Building Permit BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS— Building Inspections. 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION: Footings Stemwall Foundation Drainage/Downspouts Piers Post Holes(Pole Bldgs.) PLUMBING: Under Floor/Slab Rough-in Water Line(Meter to Bldg) Gas Line Back Flow/Water FINAL Date Accepted b AIR SEAL: Walls Ceiling FRAMING: Joists/Girders/Under Floor Shear Wall/Hold Downs Walls/Roof/Ceiling Drywall Interior Braced Panel Only) T-Bar INSULATION: Slab Wall/Floor/Ceiling MECHANICAL: Heat Pum /Furnace/FAU/Ducts Rough-in Gas Line Wood Stove/Pellet/Chimney Commercial Hood/Ducts FINAL Date Accepted b MANUFACTURED HOMES: Footing/Slab Blocking&Hold Downs Skirting PLANNING DEPT. Separate Permit#s SEPA: Parkin /Lighting ESA: Landscaping SHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE Inspection Type Date Accepted By Electrical 417-4735 Construction- R.W. PW /Engineering 417-4831 Fire 417-4653 Planning 417-4750 Building 417-4815 T:Forms/Building Division/Building Permit pORi CITY OF PORT ANGELES PUBLIC WORKS & UTILITIES v 321 EAST 5TH STREET, PORT ANGELES. WA 98362 Application Number . . . . . 13-00001352 Date 12/17/13 Application pin number . . . 588472 Property Address . . . 1612 MALONEY CT ASSESSOR PARCEL NUMBER: 06-30-01-8-5-0030-0000- REPORT SALES TAX Application type description RES NEW SFR on your state excise tax fond Subdivision Name . . . . . . Property Use . . . . . . . . to the City of Port Angeles Property Zoning . . . . . . . RESIDENTIAL MEDIUM DENSTY (Location Code 0502) Application valuation . . . . 103140 ---------------------------------------------------------------------------- Application desc res new sf ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ HABITAT FOR HUMANITY CL COUNTY OWNER 3430 HWT 101 E STE #32 PORT ANGELES, WA. PORT ANGELES WA 98362 --- Structure Information 000 000 NEW SFR --- Other struct info . . . . . TOTAL % LOT COVERAGE 40.00 CONSTRUCTION TYPE vn FIRE SPRINKLERS REQUIRED yes NUMBER OF STORIES 1.00 LOT SIZE 4500.00 PROPOSED LOT COVERAGE 1295.00 NUMBER OF UNITS 1.00 ---------------------------------------------------------------------------- Permit . . . . . . PUBLIC WORKS RES WATER SERV Additional desc . . 3/4" METER FIRE SPRINKLERS Permit Fee . . . . 420.00 Plan Check Fee .00 Issue Date . . . . 12/17/13 Valuation . . . . 103140 Expiration Date 6/15/14 Qty Unit Charge Per Extension 1.00 420.0000 EA PW WATER METER DROP IN 420.00 ---------------------------------------------------------------------------- Permit . . . . . . .PUBLIC WORKS STORMWATER Additional desc . . Permit Fee . . . . 135.00 Plan Check Fee .00 Issue Date . . . . 12/17/13 Valuation . . . . 103140 Expiration Date . . 6/15/14 Qty Unit Charge Per Extension 1.00 135.0000 EA SAN SEW / STM CON OTHER 135.00 ---------------------------------------------------------------------------- Permit . . . . . SANITARY SEWER HOOK UP Additional desc . . Permit Fee . . . . 150.00 Plan Check Fee .00 Issue Date . . . . 12/17/13 Valuation . . . . 103140 Expiration Date . . 6/15/14 Qty Unit Charge Per Extension Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work as commenced,or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. 2-f7-I Signature of Contractor or Authorized Agent Date Signature o caner(if owner is builder) Date T:Forms/Building Division/Public Works Permit PERMIT INSPECTION RECORD CALL 417-4831 FOR UTILITY INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INA CONSPICUOUS LOCATION. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED COMMENTS YES NO PW UTILITIES (Engineering Division) WATERLINE/METER SEWER CONNECTION SANITARY STORM SITE DRAINAGE SITE EROSION CONTROL PARKING SIDEWALK CURB&GUTTER DRIVEWAY APPROACH BACK-FLOW DEVICE FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED YES I NO CONSTRUCTION R.W./PW/ CONSTRUCTION-R.W. ENGINEERING 4174807 PW/ENGINEERING FIRE 4174653 FIRE DEPT. PLANNING DEPT. 417-4750 PLANNING DEPT. BUILDING 47- BUILDING 4815 T:Forms/Building Division/Public Works Permit :PORr��F CITY OF PORT ANGELES 'tea,F PUBLIC WORKS & UTILITIES 321 EAST 5TH STREET, PORT ANGELES. WA 98362 Page 2 Application Number . . . . . 13-00001352 Date 12/17/13 Application pin number . . . 588472 REPORT SALES TAX Qty Unit Charge Per Extension on your state excise tax form 1.00 150.0000 EA SAN SEWER xooxuP 150_00 to the City of Port Angeles ---------------------------------------------- Special Notes and Comments (Location Code 0502) November 22, 2013 7:53:29 AM rbecker. Is the fire sprinkler system a closed system, which requires a double check valve assembly backflow? Or is the fire system an open system(vent to tolet) , which does not need a backflow? If you have any questions call Ron Becker at 417-4886,Fax:452-4972, or E-mail:rbecker@cityofpa.us Address numbers shall be plainly visible from the street. Address numbers shall be a minimum of six inches high and be of contrasting color from the background. All homes in new subdivisions that are outside of the Fire Department four-minute response area shall be equipped with residential fire sprinkler systems that comply with the International Fire Code (IFC) and National Fire Protection Association (NFPA) . December 10, 2013 10:27:39 AM sroberds. The application will result in a new sfr in the RMD for total lot cov of 28% and site cov of 400. Reduced north side setback is 6'7" (3" modification) per a minor modification permitted per Section 17.45.040 PAMC. The development is done under an IOZ approved for the parent site; the adjustment is due to an oversight by the developer in site planning. Electrical load calculations and electrical permits are required. Consider applying for the City Green Infrastructure Rebate of up to $500.00 towards the materials to install rain garden to control roof and driveway runoff. Contact Jonathan Boehme at 360 417-4811 Trench safety per applicable laws. Temp erosion control and surface restoration responsibility of applicant. Contact City inspector prior to start of work @ 360 417-4831. No attachment to sanitary sewer of stormwater roof leaders, foundation drains, yard drains, or any other CSO 'contribution is allowed. All connections to City storm drain facilities require an inspection by Public Works and Utilities Engineering prior cover. Contact inspection hot line 48 hours in advance of commencing work @ 360 417-4831 Sanitary sewer connection inspection is required by Public Works prior to back fill of ditch. 24 hour advance notice is required. Public Works Inspection request line 417-4831 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . RES UNDERGRND SERVICE FEE 770.00 SEWER SYSTEM DELV CHARGE 2260.00 STATE SURCHARGE 4.50 Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work as commenced,or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Signature of Contractor or Authorized Agent Date Signature of Owner(if owner is builder) Date T:Forms/Building Division/Public Works Permit PERMIT INSPECTION RECORD _ CALL 417-4831 FOR UTILITY INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INA CONSPICUOUS LOCATION. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED COMMENTS YES NO PW UTILITIES (Engineering Division) WATERLINE/METER SEWER CONNECTION SANITARY STORM SITE DRAINAGE SITE EROSION CONTROL PARKING SIDEWALK CURB&GUTTER DRIVEWAY APPROACH BACK-FLOW DEVICE FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED YES NO CONSTRUCTION R.W./PW/ CONSTRUCTION-R.W. ENGINEERING 417-4807 PW/ENGINEERING FIRE 41711653 FIRE DEPT. PLANNING DEPT. 4174750 PLANNING DEPT. BUILDING 4b7- BUILDING 4815 T:Forms/Building Division/Public Works Permit OppORign,OF CITY OF PORT ANGELES U N �'1♦� PUBLIC WORKS & UTILITIES 321 EAST 5TH STREET, PORT ANGELES. WA 98362 Page 3 Application Number . . . . . 13-00001352 Date 12/17/13 Application pin number . . . 588472 REPORT SALES TAX ----------------------------- ----------- --------------- Other Fees . . . . . . . . PW WATER SYSTEM USE FEE 2260.00 on your state excise tax form Fee summary Charged Paid Credited Due to the City of Port Angeles ----------------- ---- ---------- ---------- ---------- (Location Code 0502) Permit Fee Total 705.00 705.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 5294.50 5294.50 .00 .00 Grand Total 5999.50 5999.50 .00 .00 Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work as commenced,or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Signature of Contractor or Authorized Agent Date Signature of Owner(if owner is builder) Date T:Forms/Building Division/Public Works Permit PERMIT INSPECTION RECORD z CALL 417-4831 FOR UTILITY INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED, POST PERMIT INA CONSPICUOUS LOCATION. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED COMMENTS YES NO PW UTILITIES (Engineering Division) WATERLINE/METER SEWER CONNECTION SANITARY STORM SITE DRAINAGE SITE EROSION CONTROL PARKING SIDEWALK CURB&GUTTER DRIVEWAY APPROACH BACK-FLOW DEVICE FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED YES NO CONSTRUCTION R.W./PW/ CONSTRUCTION-R.W. ENGINEERING 4174807 PW/ENGINEERING FIRE 417-4653 FIRE DEPT. PLANNING DEPT. 417-4750 PLANNING DEPT. BUILDING 417- BUILDING 4815 T:Forms/Building Division/Public Works Permit THE T NAE ES For City Use ,CIT Y ©Fpl _ -J- -11L. L Permit# _ <-- W A s t-1 i lv G T o N , U . S. Date Received: 321 E 5th Street Date Approved if '11111, Port Angeles,WA 9836 P: 360-417-4817 F: 360-417-4711 Email:permitsC@cityofpa.us BUILDING PERMIT A PLICATION Project Address: G ( Z (NA VA`0;-AE--( Ca a 0- (!!)04Ph0 ne: 3 (,o K 't 6 -t y 0 Prima Contact: N ��rLv2-V-1 v`A 1k (E Email: Cates-1iLVC totes ��}v�c3`,-�-CLP�LLVA,1,-'-017-0 Name / Phone / �`, �✓a ave u w -Ak'j (ILnLLWvL, Cour-' t - L go Property Mailing Address Email Owner. N 5C" y19 Q t--ntlt 4-1 CC--vaLt_I'owi •o City State Zip Ci3 Z Name Phone Contractor Address Email Information city state zip Contractor License# {�A F oy Z u o Exp.Date: Legal Description: Zoning: Tax Parcel # Project Value: (materials and labor) Ria $ as 103, 140 Residential IN Commercial ❑ Industrial ❑ Public ❑ Permit Demolition ❑ Fire ❑ Repair ❑ Reroof(tear off/lay over) ❑ Classification For the following, fill out both pages of permit application: (check New Construction IN Exterior Remodel ❑ Addition ❑ Tenant Improvement ❑ appropriate) Mechanical ® Plumbing ® Other ❑ Will a fire sprinkler system be installed Irrigation System? Proposed Bathrooms Proposed Bedrooms or modified? Yes EP No ❑ Yes ❑ No 91 Z 3 Project DescriptionL 5 tom, �� 5��� �3 5�o rioo, Z(bN-z"4 vaoo"' o t Z.00 - t fcaur woLIN— i t o k ,, r Is project in a Flood Zone: Yes ❑ Nop Flood Zone Type: If in a Flood Zone, what is the value of the structure before proposed improvement? $ I have read and completed the application and know it to be true and correct. I am authorized to apply for this permit and understand that it is my responsibility to determine what permits are required and to obtain permits prior to work. I understand that plan review fees are not refundable after review has occurred. I understand that I will forfeit review fees if I withdraw the application before the permit is issued. I understand that if the permit is not picked up/issued within 18o days of submittal,the application will be considered abandoned and the fees will be forfeited. Date Z(- Print Name �A avL" VZ r�v VZ Signature - 5- Residential Structures For Office Use Area Description(SQ FT) Existing Proposed ss value B m'ent { First Floor / Zoo I�I and Floor Covered Deck/Porch/Entry ck(over 30"or an floor) ge ,(; ort er(describe) Area Totals ' 2 Commercial Structures Proposed For Office Use Area Descriptions(SQ FT) Existing Proposed ss Value Existing Structure (s) Proposed Addition Tenant Improvement? Other work(describe) Site Area Totals Lot/Site Coverage Calculations Lot Size (sq ft) Lot Coverage (sq ft) %Lot Coverage (Total lot coverage_lot size) Lf5oo / Zg 5 Z�yo Site Coverage (Sq Ft of all impervious) Z 3 %of Site Coverage (total site coverage-lot size) / ! 0 g -1 lv Mechanical Fixtures Indicate how many of each type of fixture to be installed or relocated as part of this project. Air Handler Size: # Haz/Non-Haz Piping Outlets: Appliance Exhaust Fan # Heater(Suspended, Floor, Recessed wall) # Boiler/Compressor Size: # Heating/Cooling appliance # repair/alteration Evaporative Cooler(attached, not # Pellet Stove/Wood-burning/Gas # portable) Fireplace/Gas Stove/Gas Cook Stove/Misc. Fuel Gas Piping #of Outlets: Ventilation Fan,single duct # �I Fur ce/Heart P_u' / Size: # / Ventilation SystemU # Forced-Air Unit &�r Plumbing Fixtures Indicate how many of each type of fixture to be installed or relocated Plumbing Traps # Fuel gas piping #of Outlets: 0 Water Heater # Medical gas piping #of Outlets: `f' Water Line # Plumbing Vent piping # 3 Sewer Line # , Industrial waste pretreatment interceptor Grease Trap [Size Other(describe): T:\BUILDING\APPLICATION FORMS\Current BP Application\Building Permit 4-17-13.docx • • • Habitat COMMERTON RESIDENCE 1612 MALONEY COURT for Humanity of Clallarll County PORT ANGELES,WA 98363 728 E.Front Street P.O.Box 1479 HABITAT FOR HUMANITY Port Angeles,WA 988 362 360-681-6780 LOT 3 MALONEY HEIGHTS PROPERTYLINE N SANITARY SEWER io STORM WATER DRAINAGE PLAN 25-1 112"- 51'-41/2" /2" 51'-41/2" PORCH N 5'.ts'.6' 20'X 24'CONCRETE 4'CONCRETE WALK DRIVEWAY CJ 1"=15' 1202dY LIVING AREA N 1200 sq ft it Z 36 0 C W O D_ 03 O —PQWER&W 112'-6" Special Building Requirements PROPERTYLINE HOUSE TO BE NORTHWEST ENERGY STAR CERTIFIED WHOLE HOUSE SPRINKLERS REQUIRED BUILDILNG CONTINUOUSLY SHEATHED SHEAR PANELS—PRESCRIPTIVE PER 20121RCTABLE R602.10.4 TEMPERED GLASS REQUIRED IN BATHROOMS AND WINDOW AT FRON TDOOR ATTIC VENTILATION VIA CONTINUOUS RIDGE VENT AND VENTED SOFFIT ALL EXHAUST FANS VENTED TO EXTERIOR OF BUILDLING LOT AREA=4500 SQFT ENERGY RECOVERY VENTILLATOR REQUIRED=110 CFM STRUCTURE FOOTPRING=1184 SQ FT MINIMUM OF 10'SEPARATION BETWEEN INTAKE AND EXHAUST VENTS LOT COVERAGE=26% NON-VENTED WINDOWS ALLOWED LIVING AREA=1104 SQ FT BATHROOM VENTILLATION+50CFM VENTED THROUGH ROOF ROOF FOOTPRINT=1620 SQ FT RANGE HOOD FAN=100CFM PAGE 1 26,_0" 15'-3" I I I +i7-^J��u?sia-:'ms's s�,r2kc• -s4xe — —— ————————— ———— -- - K. 11'-1 112- - -- -- unlln =s I I D I nHM I D A002j039 H I � I Li - pva 1 z HiVG "z 0 Ls 00 I n POOH e6ue21 161=10 OOl I I N3H011A A00HO38 - I lsne4x3 b R pue a�elul snonulluo0 W=10 - OZ 101e1111u9A GanOOab(6j9u3 b 13SO10 -— : I I Ki I A2 Clg-d31SVA I � I I 9 ' I ONlnll I I G I I O � D OO I I 13SO-10 HO�IOcl I I r nn � �ll ,I i ---------------------� I I I , • I I—— — ——— —— —— — — —- a —— — — — — — — -- -- .J o cm'1 HABITAT FOR HUMANITY OF CLALLAM COUNTY JANET SCOTT RESIDENCE 728 E. FRONT STREET, P.O. BOX 1479 LOT 14 N v PORT ANGELES,WA 98362 (360)-681-6780 PORT ANGELES,WA 98363 12/10/2013 Plans & Permits 7,361.50 CITY OF PORT ANGELES *** CUSTOMER RECEIPT *** Oper: KEMERY Type: CT Drawer: 1 Date: 12/17/13 01 Receipt no: 120643 Year Number Amount 2013 1352 1612 MALONEY CT PORT ANGELES WA 98363 BP hUILDING PERMITS $7361.50 Trans number: 1577450 HABITAT FOR HUMANITY 7,361.50 HABITAT FOR HUMANITY 1612 MALONEY CT 2013-1352 Tender detail CK CHECK 9151 $7361.50 Total tendered $7361.50 Total payment $7361.50 Trans date: 12/17/13 Time: 12:45:38 # THANK YOU FOR YOUR PAYMENT +* FOR INQUIRIES 360-457-0411 PRESS 1 WWW.CITYOFPA.US Sue Roberds To: Harry Gravatte Subject: RE: 1612 Maloney Dear Harry, The minor modification that you requested for 1341 Maloney can be approved per Section 17.45.040 PAMC as an amended action under the Infill Overlay Zone(IOZ) Maloney Heights subdivision. We understand that the 3 inch modification requested is due to an oversight in early planning for the standard house plan that Habitat for Humanity intends to use on multiple lots within the subdivision. it is further understood that the remaining lots within the subdivision are wider than the subject lot and the standardized house plan will not pose future setback issues with that future development. Therefore, the minor modification can be issued. The CED Director will sign that modification and the plan should shortly be ready for pickup. Sincerely, jue Robberds Plant it{g d?arcc{ger City of Port Angeles U Cornnninity&F_conoinic Development P.O. Box 1150 Port Angeles, P/A 9836 lJ sroberdsa,eitvofpa.us 360-417-4750 From: Harry Gravatte [mailto:harry@habitatclallam.org] Sent: Tuesday, December 03, 2013 10:59 AM To: Sue Roberds Cc: executive Subject: RE: 1612 Maloney Sue, We are using three standardized home plans for our lots at Maloney Heights. Lots 2,3,4,11 and 12 are all using our house plan "B". Lot#3 is 40' wide, with a south side yard setback of 7' and the width of House Plan "B" leaves a north side yard setback of 6-7%". To avoid additional engineering expenses for plan redraw and survey work we request modification per Section 17.45 to allow us the 6-7%2" side yard setback . Thank you for your consideration in this matter. Harry Gravatte Construction Manager Habitat for Humanity Clallam County Cell 808 0049 1 Prescriptive Energy Code Compliance for All Climate Zones in Washington Project Information Contact Information fc? 1 Z Vti�=a`:c b Co ray t _ - r�a2vL r3�r yaT�>,A This project will use the requirements of the Prescriptive Path below and incorporate the CLL- p S; ©d the minimum values listed. In addition, based on the size of the structure, the appropriate number of additional credits are checked as chosen by the permit applicant. Authorized Representative Date ( I , z" ' ( 3 All Clim to Zones R-Valuea U-Factora Fenestration U-Factorb n/a 0.30 Skylight Ll-Factor n/a 0.50 Glazed Fenestration SHGCb,e n/a n/a Ceiling 4Y 0.026 Wood Frame Wall'-F1 21 int 0.056 Mass Wall R-Value' 21/21h 0.056 Floor 309 0.029 Below Grade Wall°,k 10/15/21 int+TB j 0.042 Slab R-Value& Depth 10, 2 ft I n/a "Table R402.1.1 and Table R402.1.3 Footnotes included on Page 2. Each dwelling unit in one and two-family dwellings and townhouses,as defined in Section 101.2 of the International Residential Code shall comply with sufficient options from Table R406.2 so as to achieve the following minimum number of credits: �1. Small Dwelling Unit: 0.5 points Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration area. Additions to existing building that are less than 750 square feet of heated floor area. F-]2. Medium Dwelling Unit: 1.5 points All dwelling units that are not included in#1 or#3, including additions over 750 square feet. ❑3. Large Dwelling Unit: 2.5 points Dwelling units exceeding 5000 square feet of conditioned floor area. Table R406.2 Summary Option Description Credit(s) 1 a Efficient Building Envelope 1 a 0.5 F 1 b Efficient Building Envelope 1 b 1.0 El 1 c Efficient Building Envelope 1c 2.0 2a Air Leakage Control and Efficient Ventilation 2a 0.5 1-1 2b Air Leakage Control and Efficient Ventilation 2b 1.0 F-1 2c Air Leakage Control and Efficient Ventilation 2c 1.5 3a High Efficiency HVAC 3a 0.5 3b High Efficiency HVAC 3b 1.0 F-1 3c High Efficiency HVAC 3c 2.0 F-1 3d High Efficiency HVAC 3d 1.0 4 High Efficiency HVAC Distribution System 1.0 5a Efficient Water Heating 0.5 5b Efficient Water Heating 1.5 F-1 6 Renewable Electric Energy 0.5 *1200 kwh 0.0 Total Credits 0.00 *Please refer to Table R406.2 for complete option descriptions http•1/www.energy.wsu.edu/Documents/2012%20Res/o20Energy.pdf Table R402.1.1 Footnotes For SI: 1 foot .= 304.8 mm, ci .= continuous insulation, int .= intermediate framing. a R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity which is less than the label or design thickness of the insulation, the compressed R-value of the insulation from Appendix Table A101.4 shall not be less than the R-value specified in the table. b The fenestration U-factor column excludes skylights. The SHGC column applies to all glazed fenestration. Exception: Skylights may be excluded from glazed fenestration SHGC requirements in Climate Zones 1 through 3 where the SHGC for such skylights does not exceed 0.30. 1.10/15/21.+TB" means R-10 continuous insulation on the exterior of the wall, or R-15 on the continuous insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the basement wall at the interior of the basement wall. "10/15/21.+TB" shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. "10/13" means R-10 continuous insulation on the interior or exterior of the home or R- 13 cavity insulation at the interior of the basement wall. "TB" means thermal break between floor slab and basement wall. d R-10 continuous insulation is required under heated slab on grade floors. See R402.2.9.1. e There are no SHGC requirements in the Marine Zone. f Basement wall insulation is not required in warm-humid locations as defined by Figure R301.1 and Table R301.1. g Reserved. h First value is cavity insulation, second is continuous insulation or insulated siding, so "13.+5" means R-13 cavity insulation plus R-5 continuous insulation or insulated siding. If structural sheathing covers 40 percent or less of the exterior, continuous insulation R-value shall be permitted to be reduced by no more than R-3 in the locations where structural sheathing is used to maintain a consistent total sheathing thickness. The second R-value applies when more than half the insulation is on the interior of the mass wall. ' For single rafter- or joist-vaulted ceilings, the insulation may be reduced to R-38. k Int. (intermediate framing) denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation. Log and solid timber walls with a minimum average thickness of 3.5 inches are exempt from this insulation requirement. Table R402.1.3 Footnote a Nonfenestration U-factors shall be obtained from measurement, calculation or an approved source or as specified in Section R402.1.3. FND. 5 8"REBAR tENGLER3O4 STAMPED 5.00' PLASTIC CAF h'LAZM1 INV SIAMPEU 1 CITY POWER UTILITY 6304" \ /"WENGLER PL "NTI-ROORDA PLS 36825" (NO CAP) EASEMENT 522.97' 44.00' 40.083.99 16.01 80.99 7.00' 80.99 54.00 10' E CITY POWER UiIU ASEMENT 10' FND. 1'CONDL 16' 2O' 0 20' 18.00' 10' WIDE SANITARYN N PLASTIC CAP_' LOT 9 o LOT 7 • SEWER EASEMENT �A j27 (o Sfi N 'CLARK LS 122 171LI77ES EASEMENT \ cn N 3677'33" W. OF CITY - cn 4202 SQ. FTD. \ 70• 4205 SQ. FT. 10 6• 7' 7' L +.9CALCULATED P 20' r �o20' \ o Z 1621 LOT 5 74T. w10' NIDE SANITARY � \u 4923 SQ. TOLT 4LOT25SEWER EASEMENT 80.99' a I(OZO A u N O: 498 S2 W N 33'15'29"E \ 161.96' +- 729 SQ. T. w s: •\\`� 1s' \ f 271 G-2,2 \\ "' 1(c u4 1b1Z 9 F 25 \ LOT 8 \ LOT 6 N 7 11. F 7 :Sj wu4211 SQ. FT. 0 4212 SQ. FT. FT. og2'01 e R3 st o20' Lv o80.96' zo 80.99' L=31.42' N 33'1529 E 161.96 R=20.00' COMMON OPENSPACE \ COMMON OPENSPACE \ N 4 9000'00"......•... .o C cn \ \ PLAY AREA \ .'....i':,..:: ':'.'o i. \ GARDEN AREA & :10".:...:.:..�.....cn ..'.'..L- 0.25' . u 10' 1991 S0. FT. m Q.'.':... 1239 SO. FT. \ '.'R-10.00' 1 O' p•� \ rn 85.99' U vi ....45843'19"':':: ��OVl7 1 \ N HABITAT. 8.00' \ c" \ �4E \ ARKING OPENSPACE COMMON AREA \ mS 5 3375 29 W 12' \ GATED \ \\ 10994 50. FT. \ \ �\ \ \ \ 211 17 DEPAR \ \ \ACCESS 30' WIDE UTILITIES EASEMENT IN FAVOR OF CITY \ 10 WIDE CITY POWER :."UTILITY EASEMENT a 85.99' � L=31.42' 16.44 S56'44'31"E 10' _ \ �/ �.�.'... ���109.35'.�.�:�.�.�.�:'.'-�:::'��-:'.�.�..� R=20.00' .�..�,�."N 3315'29'E���.'.-.'.'.�.:�:........ ...... ... .-. \ N3315'29E 5.95' N 3315'29'E 145.50' �. 42.00' 42,00' 55.99' 4=90'00'00" .\\ \ 8• 163.50' � 10' NIDE SANITARY o SEWER EASEMENT o � e 8' WIDE UTILITIES EASEMENT _ \ IN FAVOR OF CITY a N o 31i 5 W ��' 5� LOT 13 �1,a0 yah \ 6' s' w o 4170 S0. FT. \ \ del \ \ 20' WIDE UTILITIES EASEMENT ! 25 \ \ \ IN FAVOR OF CITY N 3315'29"E \ LOT 15 7 - LOT 10 LOT 11 _ LOT 12 75.99 \ \\ 42765 SQ. FT. A w 951 SQ. FT. a 726 SQ. F .N w 725 SQ. T. LOT 14 6 e 4294 SQ. F . \1a\ h \ \ I 20' 15' \ \ 0 ry N \ 168.00' 10' 179.20' 44.00' 42.00' 42.00' 75.99' N 3314'38"E 669.96 o FND. 5/8'REBAR WITH 10' WIDE CITY POWER o PLASTIC CAP STAMPED LEGEND: (UNLESS OTHERWISE INDICATED) UTILITY EASEMENT -N71-ROORDA PLS 36825" ...EXTERIOR OF PARCEL SUBJECT TO SUBDIVISION FWD. 1" CONDUIT WITH INTERIOR LOT LINE PLASTIC CAP STAMPED ...CENTERLINE OF STREET RIGHT OF WAY "CLARK LS 72223" ...LIMITS OF STREET RIGHT OF WAY ' ...EASEMENT LINE -- " ..ADJOINING:PARCEL BOUNDARY . COMMERTON RESIDENCE Habitat 1612 MALONEY COURT for Humanity PORT ANGELES, WA 98363 of Clallam County 728 E. Front Street— P.O. Box 1479 HABITAT FOR HUMANITY Port Angeles, WA 98362 360-681-6780 LOT 3 MALONEY HEIGHTS PROPERTYLINE 04 SANITARY SEWER STORM WATER DRAINAGE PLAN zo 25'-1 1/2" 51'-41/2" PORCH N 66-5.X12'-6• 20'X 24' CONCRETE 4'CONCRETEWALK DRIVEWAY �� N 1 " - 15' PORCH LIVING AREA 4'-0'x 3'-7" N 1200 sq ft W 0 z_ �j J - 36' C: LLI� 0 Cl 7v OF PORT AF°Gk_LEq—Ctonstrue,''s®ns10 O The Issuance of Phis permi,.1-.--•;anon these pans sprifi- 0 cations and other datz ZQWER &W not FJ17` x the building official ~ _ from thereafter reo,�•,c: the Corr­`:­t,t, of errors in szid p!aas, specifications ar,d 0,,,,-er data er front preventing building ocerations i.ci;r,; carried on t:.areunder when in violation of ail codes -CPT 1711\1 In "' of this jurisdiction. 112'-6" r,F,,rcval Jate /� ;/ � Special Building Requirements PROPERTY LINE � IBy�e� HOUSE TO BE NORTHWEST ENERGY STAR CERTIFIED WHOLE HOUSE SPRINKLERS REQUIRED BUILDILNG CONTINUOUSLY SHEATHED SHEAR PANELS—PRESCRIPTIVE PER 2012 IRC TABLE R602.10.4 TEMPERED GLASS REQUIRED IN BATHROOMS AND WINDOW AT FRON TDOOR ATTIC VENTILATION VIA CONTINUOUS RIDGE VENT AND VENTED SOFFIT ALL EXHAUST FANS VENTED TO EXTERIOR OF BUILDLING LOT AREA= 4500 SQFT ENERGY RECOVERY VENTILLATOR REQUIRED = 110 CFM STRUCTURE FOOTPRING = 1184 SQ FT MINIMUM OF 10' SEPARATION BETWEEN INTAKE AND EXHAUST VENTS LOT COVERAGE = 26% NON-VENTED WINDOWS ALLOWED LIVING AREA= 1104 SQ FT BATHROOM VENTILLATION + 50CFM VENTED THROUGH ROOF ROOF FOOTPRINT= 1620 SQ FT RANGE HOOD FAN = 100CFM PAGE 1 Date: 9-26-11 J 1/2*X 9"ANCHOR BLT SET 26'-4 1/2" AT MINIMUM 4'O.0 O CLIENT TO PROVIDE EXACT PLACEMENT i TO CONTRACTOR i 13'-1 1/2" 13'-3" 2"R-10 EXTRUDED POLYSTYRENE ,(DOW BLUEBOARD)CONTINUOUS — — — — — — — — it I PERIMETER INSULATION - � 4"CONCRETE SLAB ON GRADE,3000 i �I ;PSI WITH FIBERGLASS FIBER 3"SQUARE HOT DIPPED GALVANIZED WASHER 1 2'R-10,EXTRUDED POLYSTYRENE ;DOW BLUEBOARD)WITH SEAMS 2 X 6 PRESSURE TREATED PLATEBTAPED FOR VAPOR BARRIER jZ1,' 44"MINIMUM COMPACTED 2 X 6 FOAM SILL SEAL r' ,, �' /STONE OR REJECT SAND W — — — — — — — J FINISHED GRADE AT 6"IN 10' v :i-'..., f:.�., Z 00 SLOPE,MINIMUM 6"TO TOP / W C14 I I OF FOUNDATION CN 4"TIGHTLINE DRAIN FOR III III—III _va \ W DOWNSPOUTS CONNECTED =�� Y_I I I—) I ~ J TO STORM DRAIN f`t ~ W CV --� }}II \ COMPACTED NATIVE SOIL O I 4"PERFORATED FOUNDATION IIIIII-I-I� ,`•� 0 Z DRAIN(IF REQUIRED)WRAPPED I III—III-I a 4 -_I—_ �, Q WITH GEOTEXTILE FABRIC, -�I-{' �� _ �i14 GRADE 60 REBAR AT W SURROUNDED BY WASHED -f I c�I �� 48"O.C.W ITH 6"HOOK Z w ROCK AND CONNECTED TO < 0 d a a a STORMDRAIN Z w Q 3 I �#4 GRADE 60 CONTINUOUS REBAR OVERLAPPED 20"AT JOINTS Z o x 0 - ° W I /1 DETAIL -- SLAB AND EXTERIOR STEM WALL t4'- „ N co M I � F- �2�, I I � 00 II II 00 4" CONCRETE SLAB ON GRADE, � Simpson Wedge Anchors 1/2"x 9" ,,F'c= 3000 PSI, WITH J with Minimum 7" Embedment, /% FIBERGLASS FIBERS J co Capped with 3"x 3" Hot Dipped i X co Galvanized Square Bearing Plate, 2", R-10, EXTRUDED C) 0 " 1� I Spaced at 48" O.C. minimum \ / POLYSTYRENE INSULATION U_ m (DOW BLUEBOARD), SEAMS 0 O N TAPED FOR VAPOR BARRIER a M - - - 00 �} 4" COMPACTED STONE Q W Q W IIIIII OR REJECT SAND N.1= = =1 11=F•= 1=1 1=1 I uj IM URADE 60 CONTINUOUS W REBAR, OVERLAPPED 0"AT 0 Z W r` JOINTS AND TIED TO CROSSING OW 0 C_9 — — — — — — REBAR AT T O.C., SUPPORTED 0Y Z BY BLUEBOARD Q W Q 3'-9" 11'-6" j m W / "DETAIL- INTERIOR 12DEEP THICKENED FOOTINGS FOR SHEAR WALLS00 = tiIL 26'-4 1/2" 2 OF 17 Date: 9-26-11 44'-0" D TEMPERED 2020 4030 Dw 6040 D r . II 15'-3 1/4!- ...... /4!-- D 7'-0" W M 26'-8 1/2" v M z co W rn O)l Q U) U) 35'-113/8" r" C) z D I F- z NN w 43'-6 1/2" r,... ° a LL v zo CN v .Q I D N11 i -7 26 00 47-6 112117 r N S. , O) co (o ° �_ ' F ' o - .v_ � - J 'M _- rte- 11 ✓ v " IOY 1 - CD - 3T-5"3/4: :m I N - - 34=111/ � 411 i ce) T co '24'-8:3/4' Lu F— F— dN - Q < W zr 21'-3 1/4" ui -. R'i' c t�s l ...a r- c u'._. : a «x { .'_nA�. ui;; '�-&y'y,_`., i - �u.s ca 4046 4046 D4046 2020 to 0 z W Egress Egress Egress TEMPERED 0 Z Q LL Q I_- �- W co 00 EXTERIOR BRACED WALL PANELS PER 2009 IRC TABLE R.602.10.5 INTERIOR BRACED WALL PANEL PER 2009 IRC R.602.10.2 2 ti d 4BY 8'BY 7/16"OSB PANEL APPLIED DIRECTLY TO FRAMING ON ONE SIDE, USING 8D NAILS 4 48"WIDE PANEL WITH 5/8"GYPSUM WALL BOARD BOTH SIDES 3 ALL FREE EDGES BLOCKED WITH 1 1/2"W OR S SCREWS PER ASTM C 1002 AT 7"O.C. ON EDGES AND FIELD PAGE -- ----NAIL SPACING AT-PANEL EDGES=3'-O-C-NAIL SPACING-IN THE FIELD-=12"-O�C-.---- - - - -BL•OC-K-ALL-HORIZONT-AL—JOINTS.--NO-F-IOLD-DOWNS REQUIRED NAILS AT BOTTOM PLATE TO BE HOT DIPPED GALVANIZED 3/ [/OF 17 Date:9-26-11 44'-0" D TEMPERED D 4030 D 6040 D "UN 15'-3 ME : ' -- -------- - — — — — — — — — — I ' II i I II w 15'-3 1/4" D I 7'-0" - I I w to _ 26'-8 1/2" I O CO z co w w v � I i � J o w 35'-113/8" o I W O O � I I � Q D I I I I e w F- F- IINr Z I v. - II a = �= IN- - - II w — — — — — — — — — — — — — — — — — — — - 1 N I }- - 26'-7 13/16 co - _ NLoI 0) co = r I Q in -' J d C> cv EO co -4 o I J O M ao oo 04 V m o 37'-5 3/4" LL M O O C4 j 34'-11 1/4" 00 a� r' 3/4 24'-8 " 0)- ' F— w ^ cfl � N z W zo Q Q 21'-3 1/4" _ 19 I � ._ I 2 U) U) w 4046 4046 4046 2020 w O z W Egress Egress D Egress TEMPERED W O C� QLL Q F= W COI— _.. _.. Q N o EXTERIOR BRACED WALL PANELS PER 2009 IRC TABLE R.602.10.5 INTERIOR BRACED WALL PANEL PER 2009 IRC R.602.10.2 4'BY 8'BY 7/16"OSB PANEL APPLIED DIRECTLY TO FRAMING ON ONE SIDE, USING 8D NAILS <_ � 48"WIDE PANEL WITH 5/8"GYPSUM WALL BOARD BOTH SIDES 3 ALL FREE EDGES BLOCKED WITH 1 1/2"W OR S SCREWS PER ASTM C 1002 AT 7"O.C. ON EDGES AND FIELD PAGE ------- --- NAIL SPACING-AT-PANEL EDGES=3'-O.C. NAIL SPACING IN 1"H�f'IELD= 12"O.0 BLOCK"ALL HORIZONTAL JOINTS. NO HOLD-DOWNS REQUIRED NAILS AT BOTTOM PLATE TO BE HOT DIPPED GALVANIZED OF 17 Date: 9-26-11 44'-0" I I _ Y I ,a I I i �i -----r A',Jy 7$CFM Ss+S f I = FAN onNol wco NO-1 O [Zig Tv cc'° I z rn AvLeoch \ O 0' m n m l I I I I ¢ x -n =3i cQ I I w o: Q C - w00 " moo`` f TJ II w iDI _I iRr 0 II < FAl it o 0 m I I Z I I cn z ,2 I � � I I H- "T` H TQ �S l=C y a- v I = I W OVtT� . z 1 , ,° _ a; .a. - I o 0 a a o N I • o a I I i I I I a •. o � i i I I •a — — — — — — — — — — — — — — — — — — — — rt — N co (0 ^ I O OI co oo � ( J Nt m D —miitI J o _ UDsx co 3 m cn o ----- O m - I LL. n I O O 04 r— 70 CFM }- W cY) O O FAN I H 00 Cl) F-- 0') lWal F AEli FAz F A r I = cn vi ,._, ..> m:k,..bac, ,..F.rh...x3,,:a '1".'��._'e,:gu;. — •s;._,.-. firk,� 3.r.s' s�....s' u;';R.a: `-?: :"-tea,', , .;,d r__ F :'�i�_r_ I .s'# a. .c�-.<' .e.:-" F-.sus, 4, ,� LLF- J pzw — — 48'-0" — Q LL- Q I_– W I— m 00 � 51'-0" = N PAGE 4 OF 17 Date: 9-26-11 W co U io Z rn W W s U Z n v Q H Q 0�A d LIU FRONT ELEVATION ri 11 EAST ELEVATION �- Z D 00 O t-- 00 `00 CO J O J O M U m LL 00 CV N CL oo Z F— rn < W = UW �❑ LL 0 Q U- Q F— uj F- REAR ELEVATION Q � p WEST ELEVATION 2 t-- 0- PAGE 5 OF 17 Date: 9-26-11 8., I 7/16 OSB M 2" EXTRUDED POLYSTYRENE I la— z o w I p < o 1 _o .. I , z o � cf) U PRESSURE TREATED 1 X 2 3/4 BATTEN a� c" Q U O LL_ JIL O co x Lu L I o p R-21 ROXUL INSULATION 8 1/4" X 12' HARDIE CEDARMILL SIDING /WITH 6 7/8" REVEAL x .....L.. . ... .. O N _ } 1 1/2" H.D. GALVANIZED I.... Lw 5/8" SHEETROCK� �� Z o /ROOFING NAIL X O 00 v 4 1/2'' SCREW AT 24" O.C. TO J rn 00 ATTACH FURRING TO STUDS W I J C) w ~ J X co Q / ZO I 0 m /SIDING STARTER STRIP 2" WIDE COa ILL o � E / o f 0 0 Q �_ 1 z / xo F M W H ' LL. CAULK PLATE TO SLAB �__, �* W Y �I �— F— m x :5z i 1 '+ z Q W Q n cn W .�� WINDOW SCREEN FOR BUG CONTROL w v (STAPLE TO FRONT OF OSB, INSTALL (oQ _ U) U) /16" R� ---`,BLUEBOARD ON BEAD OF CAULK AT _ _� w J FOUNDATION, WRAP SCREEN UP AND Q z O Z W ui Q OVER 1 X FURRING AND STARTER LL. O z STRIP AND STAPLE TO 1 X FURRING) r z < LL 4 3/4" \ ° Q ~ LLI 2" X 1" Z FLASHING TO PROTECT o = Q ap O BOTTOM OF BLUEBOARD D m = IZ o Q W __ - — - - -- - - __---- - PAGE EXTERIOR INSULATION AND RAIN SCREEN DETAIL 6 OF 17 Date: 9-26-11 5/12 PITCH SITE BUILT 1" POLYSTYRENE BETWEEN TRUSS R-50 BLOWN IN INSULATION- ___- -- CHORDS w cc Q co wz 00 Q C7 Poo a) IL Ch�O 24" WIDE VENTED HARDISOFFIT w ui % % r w U) o w U) % Q Z / W� Q ,TRUSS BLOCKING \ Q0 d /4/4 X 2 TRIM f TRUSS BOTTOM CHORD HURRICANE CLIPS AT ALL % ��, 2'-0" } TRUSS/PLATE INTERSECTIONS F- -� \\ WINDOW SCREEN FOR BUG CONTROL z o D 00 7/16 OSB---- `\ (STAPLE TO FRONT OF OSB, INSTALL O BLUEBOARD ON BEAD OF CAULK AT r. FOUNDATION, WRAP SCREEN UP AND rn 00 R-21 ROXUL INSULATION OVER 1 X FURRING AND STARTER J� _ co \` CD STRIP AND STAPLE TO 1 X FURRING) Q X co 5/8" SHEETROCK% U m " �-PRESSURE TREATED 1 X 2 BATTEN (3/4") LL 2" EXTRUDED POLYSTYRENE \� ��8 1/4" X 12' HARDIE CEDARMILL SIDING a -0 TAPED AT SEAMS WITH 6 7/8" REVEAL F rn '--1 1/2" H.D. GALVANIZED ROOFING NAIL < W \ _----_4 1/2" SCREW AT 24" O.C. TO _ U j w ATTACH FURRING TO STUDS F- ,j LL OQ Q LL Q H I- SOFFIT AND ATTIC INSULATION/VENTILLATION DETAIL Q ° o = tip ------ - -- /- -- - 7 0f 17 Date: 9-26-11 .. ........ ........ ......... ........ .......... .......... ......... ........... ............ WP - - - - - - - - - - - -2- �7 ss 7-9 CFM FC1 GFCI _i, G 0 FAN l-T W M w CC)TI,foil D/ (o c) M 0 M z 00 x fn :3 GFC1 CY) w o w 0 r S, �, CD 0: Wp �7 G C1 :3 0 GFQ11 r- 0 w .0 0 (D CD D r 0 0 < z "7 CD < r->Uc--r ovao- Z L E; (D 3 w Z CD 0 0 (D rp$ 0 0) 0 :3 171 CL CL 3. 3. C) co (o Jm 00 cn N C) < X (o co 0 cf) LL 0 b N M 10 77�1 70 CFM (Y) - F- 06 FAN cnZ LU < w < M D R t W. , U) Mi Dw 0 Z ui LL- 0 (D WP z < LL ...... ........ wco 00 o T- -----.---- ('4 T- -----.---------------Ll-GHTI-N-G-TO-BE-1-00%.-H-1-G- H--EFFIC- -l-E-N-CY--. - -- PAGE SMOKE DETECTORS TO BE INTERCONNECTED .8X /0 F 17 COMMERTON RESIDENCE Habitat 1612 MALONEY COURT for Humanity' PORT ANGELES, WA 98363 of Clallam County 728 E. Front Street— P.O. Box 1479 HABITAT FOR HUMANITY Port Angeles, WA 98362 360-681-6780 LOT 3 MALONEY HEIGHTS PROPERTYLINE 04 SANITARY SEWER STORM WATER DRAINAGE PLAN co 25'-1 1/2" 51'-41/2" PORCH N 6'_5.x12'_6. 20'X 24' CONCRETE IL 4'CONCRETEWALK DRIVEWAY (V PORCH LIVING AREA 4'0"x3'7" i N 1200 sq ft � LLI 0 Z_ J - 36' w COLLI p — — — .QWER &W l % 112'-6" Special Building Requirements PROPERTYLINE HOUSE TO BE NORTHWEST ENERGY STAR CERTIFIED WHOLE HOUSE SPRINKLERS REQUIRED BUILDILNG CONTINUOUSLY SHEATHED SHEAR PANELS— PRESCRIPTIVE PER 2012 IRC TABLE R602.10.4 TEMPERED GLASS REQUIRED IN BATHROOMS AND WINDOW AT FRON TDOOR ATTIC VENTILATION VIA CONTINUOUS RIDGE VENT AND VENTED SOFFIT ALL EXHAUST FANS VENTED TO EXTERIOR OF BUILDLING LOT AREA = 4500 SQFT ENERGY RECOVERY VENTILLATOR REQUIRED = 110 CFM STRUCTURE FOOTPRING = 1184 SQ FT MINIMUM OF 10' SEPARATION BETWEEN INTAKE AND EXHAUST VENTS LOT COVERAGE = 26% NON-VENTED WINDOWS ALLOWED LIVING AREA= 1104 SQ FT BATHROOM VENTILLATION + 50CFM VENTED THROUGH ROOF ROOF FOOTPRINT= 1620 SQ FT RANGE HOOD FAN = 100CFM PAGE 1