HomeMy WebLinkAbout1835 W. 15th Street Address: th 1835 W 15Street PREPARED 2/11/16, 13:43:45 INSPECTION TICKET PAGE 1 _ CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 2/11/16 ADDRESS 1835 W 15TH ST SUBDIV: CONTRACTOR GROFFS CONSTRUCTION PHONE (360) 460-8891 OWNER ICARUS L HALL PHONE (360) 460-8760 PARCEL 06-30-00-0-4-0555-0000- APPL NUMBER: 15-00001116 RES NEW SFR ------------------------------------------------------------------------------------------------ PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL . REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ BL1 01 9/25/15 JLL BLDG FOUNDATION FOOTING 9/25/15 AP September 25, 2015 8:26:24 AM jlierly. Casey 460-8891 September 25, 2015 3:56:13 PM jlierly. BL2 01 10/05/15 JLL BLDG FOUNDATION STEM WALL 10/05/15 AP October 5, 2015 8:59:51 AM jlierly. Casey October 5, 2015 4:00:24 PM jlierly. BFF 01 10/15/15 JLL BLDG FLOOR FRAMING 10/15/15 AP October 15, 2015 8:59:24 AM jlierly. CASEY 460-8891 October 15, 2015 3:45:26 PM jlierly. BEXS 01 12/30/15 JLL BLDG EXTERIOR SHEETING - 12/30/15 AP December 30, 2015 10:29:19 AM jlierly. Casey 460-8891 December 30, 2015 4:30:29 PM jlierly. BAIR 01 1/05/16 JLL BLDG AIR SEAL 1/05/16 AP January 5, 2016 9:18:21 AM jlierly. Casey 460 - 8891 January 5, 2016 4:10:42 PM jlierly. BL3 01 1/05/16 JLL BLDG FRAMING 1/05/16 AP January 5, 2016 9:18:49 AM jlierly. January 5, 2016 4:10:42 PM jlierly. BLI O1 1/07/16 PB BLDG INSULATION 1/11/16 AP January 7, 2016 10:22:32 AM pbarthol. Casey 460-8891 January 11, 2016 10:00:59 AM pbarthol. BLFD 01 1/08/16 PB BLDG FOUNDATION DRAINAGE 1/11/16 AP January 8, 2016 9:03:12 AM pbarthol. January 11, 2016 10:00:59 AM pbarthol. BL1 02 1/08/16 PB BLDG FOUNDATION FOOTING 1/11/16 AP January 8, 2016 9:03:31 AM pbarthol. January 11, 2016 10:00:59 AM pbarthol. DRW 01 1/08/16 PB BLDG DRYWELL 1/11/16 AP January 8, 2016 9:03:46 AM pbarthol. January 11, 2016 10:03:22 AM pbartho BLDR 01 1/11/16 JLL BLDG DRYWALL IBWP 1/11/16 AP January 11, 2016 4:38:33 PM jlierly. Casey January 11, 2016 4:40:11 PM jlierly. PW99 01 2/08/16 RV PUBLIC WORKS FINAL 2/08/16AP February 8, 2016 2:01:46 PM rvess. February 8, 2016 2:02:06 PM rvess. - BL99 01 2/11/16 J BLDG FINAL February 11, 2016 8:40:58 AM jlierly. Casey PERMIT: ME 00 MECHANICAL PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS --------------—-------------------------------------------------------------------------------- ----------------------------------- CONTINUED ONTO NEXT PAGE ----------------------------------- { PREPARED 2/11/16, 13:43:45 INSPECTION TICKET PAGE 2 CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 2/11/16 -------------------- --- ADDRESS 1835 W 15TH ST SUBDIV: CONTRACTOR GROFFS CONSTRUCTION PHONE (360) 460-8891 OWNER ICARUS L HALL PHONE (360) 460-8760 PARCEL 06-30-00-0-4-0555-0000- APPL NUMBER: 15-00001116 RES NEW SFR ------------------------------------------------------------------------------------------------ REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ---------------------------------------------------------—----------—----------------------- ME1 01 1/05/16 JLL MECHANICAL ROUGH-IN 1/05/16 AP January 5, 2016 4:10:19 PM jlierly. January 5, 2016 4:10:42 PM jlierly. ME99 01 2/11/16L MECHANICAL FINAL February 11, 2016 8:41:17 AM jlierly. PBRMIT: PL 00 PLUI�IDI G ERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ PL2 01 1/05/16 JLL PLUMBING ROUGH-IN 1/05/16 AP January 5, 2016 4:09:56 PM jlierly. January 5, 2016 4:10:42 PM jlierly. PL6 01 1/08/16 PB PLUMBING WATER SUPPLY 1/11/16 AP January 8, 2016 9:03:58 AM pbarthol. January 11, 2016 10:03:22 AM pbartho PL99 01 2/11/16 PLUMBING FINAL February 11, 2016 8:41:33 AM jlierly. --------------------- --------- COMMENTS AND NOTES -------------------------------------- CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT- BUILDING DIVISION 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Application Number . . . . . 15-00001116 Date 9/24/15 Application pin number . . . 560464 Property Address . . . . . 1835 W 15TH ST ASSESSOR PARCEL NUMBER: 06-30-00-0-4-0555-0000- REPORT SALES TAX Application type description RES NEW SFR on your state excise tax form Subdivision Name . . . . Property Use . . . . . . .. . to the City of Port Angeles Property Zoning . . . . . . . RS7 RESDNTL SINGLE FAMILY (Location Code 0502) Application valuation . . -123627 \ Application desc 1269sf 1 STRY SFR W/520sf ATTACHED GARAGE 3BD 2BAT -------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ ICARUS L HALL GROFFS CONSTRUCTION 1115 E FRONT ST 736 E 9TH ST PORT ANGELES WA 98362 PORT ANGELES WA 98362 (360) 460-8760 (360) 460-8891 --------------------------------'-------------------------------------------- Permit . . . . . . BUILDING PERMIT -RESIDENTIAL Additional desc 1269SF SFR W/520SF GARAGE Permit Fee 1154.65 Plan Check Fee .00 Issue Date . . . . 9/24/15 Valuation . . . . 123627 Expiration Date 3/22/16 Qty Unit Charge Per Extension BASE FEE 1020.25 24.00 5.6000 THOU BL-100,001-500K (5.60 PER K) 134.40 ----------------------------------------- ---------------------------------- Permit . . . . . . MECHANICAL PERMIT Additional desc . . SFR MECHANICAL Permit Fee . . . . 163.95 Plan Check Fee .00 I Issue Date . . . . 9/24/15 Valuation 0 Expiration Date 3/22/16 V' Qty Unit Charge Per Extension BASE FEE 50.00 !� 2.00 7.2500 EA ME-VENT FAN (SINGLE DUCT) 14.50 1.00 10.6500 EA ME-HOOD/DUCT-MECH. EXHAUST 10.65 6.00 14.8000, EA ME-HEATER(SUSP/WALL/FLOOR-MTD) 88:80 ---------------------------------------------------------------------------- 1 Permit . . . . . . PLUMBING PERMIT VR Additional desc SFR PLUMBING Permit Fee . . . . 161.00 Plan Check Fee .00 Issue Date . . . . 9/24/15 Valuation . . . . 0 \Mv1 Expiration Date 3/22/16 Qty Unit Charge Per Extension BASE FEE 50.00 8.00 7.0000 EA PL-PLUMBING TRAP 56.00 1.00 7.0000 EA PL-WATER LINE 7.00 4.00 7.0000 EA PL-DRAIN VENT PIPING 28.00 1.00 15.0000 EA PL-SEWER LINE 15.00 Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized isnot commenced within 180 days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced,or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does i not presume to give authority to violate or cancel the provispfwkof any state or I law regulating construction or the performance of construction)/,5- DIet kq Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder) Tforms/Building Division/Building Permit BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS— Building Inspections 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL,TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION: Footings Stemwall Foundation Drainage/Downspouts Piers Post Holes(Pole Bldgs.) PLUMBING: Under Floor/Slab Rough-In Water Line Meter to Bldg) Gas Line Back Flow/Water FINAL Date Accepted b AIR SEAL: Walls Ceiling FRAMING: Joists/Girders/Under Floor Shear Wall/Hold Downs Walls/Roof/Ceiling Drywall Interior Braced Panel Only) T-Bar INSULATION: Slab ` Wall/Floor/Ceiling MECHANICAL: Heat Pum /Furnace/FAU/Ducts Rough-In Gas Line Wood Stove/Pellet/Chimney Commercial Hood/Ducts FINAL Date Accepted b MANUFACTURED HOMES: Footing/Slab Blocking&Hold Downs Skirting PLANNING DEPT. Separate Permit#s SEPA: Parkin /Lighting ESA: Landscaping SHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE Inspection Type Date Accepted By Electrical 417-4735 Construction- R.W. PW I Engineering 417-4831 Fire 417-4653 Planning 417-4750 Building 417-4815 T:Forms/Building Division/Building Permit CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY&ECONOMIC DEVELOPMENT-BUILDING DIVISION `.� 321 EAST 5TH STREET, PORT ANGELES,WA 98362 Page 2 Application Number . . . . . 15-00001116 Date 9/24/15 Application pin number 560464 REPORT SALES TAX Qty Unit Charge Per Extension on our state excise tax form. 1.00 7.0000 EA PL-WATER HEATER 7.00 ---------------------------------------------------------------------------- to the City of Port Angeles Special Notes and Comments Location Code 0502) Address numbers shall be plainly visible from the street. Co, de numbers shall be a minimum of six inches high and be of contrasting color from the background. A residential fire sprinkler system, installed per NFPA 13D, will be required. 2nd option is to install an outside alarm bell that is inter-connected to the residence's smoke detectors. The alarm bell will be painted red in color and identified as "Fire alarm" Electrical load calculations and electrical permits are required. Standard Stormwater Comments for-temporary erosion control. NOTE: Site work started prior to permit, and soil was being tracked off site. This site must be brought into compliance with City of Port Angeles Erosion Control Standards! This includes 1. Establishing Construction Access. 2. Install sediment controls BMPs. 3. Stabilize exposed soils. 4. Protect slopes from erosion. - 5. Protect drain inlets. 6. Control pollutants including but not limited to spills, concrete wash out, exposed aggregate processes, concrete grinding and saw cut waste water. 7. Maintain temporary and permanent erosion control BMPS during project. All disturbed area's on site not covered by new improvements should meet the attached soil quality and depth standard. Consider applying for the City Green Infrastructure Rebate " of up to $750.00 towards the materials to install rain garden to control roof and driveway runoff. Also rebates available for downspout disconnections.Contact Jonathan Boehme at 360 417-4811 All construction work within the City right of way requires a separate Right of Way Construction application to be completed by the contractor and approved by Public Works Engineering prior to the start of work. A pedestrian or traffic control plan is to be submitted for approval with the application as necessary. Trench safety per applicable laws. Temp erosion control and surface restoration responsibility of applicant. Contact City inspector prior to start of work @ 360 417-4831. No attachment to sanitary sewer of stormwater roof leaders, foundation drains,. yard drains, or any other CSO contribution is allowed. Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized isnot commenced within.180 days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced,or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder) T:Forms/Building Division/Building Permit BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS— Building Inspections. 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION: Footings Stemwall Foundation Drainage/Downspouts Piers Post Holes(Pole Bldgs.) PLUMBING: Under Floor/Slab Rough-in Water Line Meter to Bldg) Gas Line Back Flow/Water FINAL Date Accepted b AIR SEAL: Walls Ceiling FRAMING: Joists/Girders/Under Floor Shear Wall/Hold Downs Walls/Roof/Ceiling Drywall Interior Braced Panel Only) T-Bar INSULATION: Slab Wall/Floor/Ceiling MECHANICAL: Heat Pum /Furnace/FAU/Ducts Rough-in Gas Line Wood Stove/Pellet/Chimney Commercial Hood/Ducts FINAL Date Accepted b MANUFACTURED HOMES: Footing/Slab Blocking&Hold Downs Skirting PLANNING DEPT. Separate Permit#s SEPA: Parking/Lighting ESA: Landscaping SHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE Inspection Type Date Accepted By Electrical 417-4735 Construction-R.W. PW /Engineering 417-4831 Fire 417-4653 Planning 417-4750 Building 417-4815 T:Forms/Building Division/Building Permit CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY& ECONOMIC DEVELOPMENT- BUILDING DIVISION 321 EAST 5TH STREET, PORT ANGELES,WA 98362 Page 3 Application Number . . . . . 15-00001116 Date 9/24/15 Application pin number - 560464 - - REPORT SALES TAX Special Notes and Comments on your state excise tax form Sanitary sewer connection inspection is required by Public Works prior to back fill of ditch. 24 hour advance to the City of Port Angeles notice is required. Public Works Inspection request line Location Code 0502) 417-4831 The contractor making the connection to an existing water meter is responsible to adjust water meter depth so that there is a minimum of 4 to 6 inches of clearance between the bottom of the meter box lid and the top of the meter at finish grade. Use existing driveway curb opening. Construct driveway to City Standards. Concrete with exposed aggregate or other non-standard finishes(including colors or dyes)are not allowed in the City road right of way. Broom finish only. An inspection by Public Works Engineering is required prior to pouring concrete. Public Works inspection request line 417-4831. ------------------------------------------------------------------ Other Fees . . . . . . . . RES UNDERGRND SERVICE FEE 770.00 SEWER SYSTEM DELV CHARGE 2260.00 STATE SURCHARGE 4.50 PW WATER SYSTEM USE FEE 2260.00 ---------------------------------------------------------------------------- , Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 1481.60 1481.60 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 5294.50 5294.50 .00 .00 Grand Total 6776.10 6776.10 .00 .00 i Separate Permits are required forelectrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. - Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder) T:Forms/Building Division/Building Permit BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS-- Building Inspections. 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION: Footings Stemwall Foundation Drainage/Downspouts Piers Post Holes(Pole Bldgs.) PLUMBING: Under Floor/Slab Rou h-In Water Line Meter to Bldg) Gas Line Back Flow/Water FINAL Date Accepted b AIR SEAL: Walls Ceiling FRAMING: Joists/Girders/Under Floor Shear Wall/Hold Downs Walls/Roof/Ceiling Drywall Interior Braced Panel Only) 1 T-Bar INSULATION: Slab Wall/Floor/Ceiling MECHANICAL: Heat Pum /Furnace/FAU/Ducts Rough-in Gas Line Wood Stove/Pellet/Chimney Commercial Hood/Ducts FINAL Date Accepted b MANUFACTURED HOMES: Footing/Slab Blocking&Hold Downs Skirting PLANNING DEPT. Separate Permit#s SEPA: Parkin /Lighting ESA: Landscaping SHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE Inspection Type Date Accepted By Electrical 417-4735 Construction- R.W. PW /Engineering 417-4831 Fire 417-4653 Planning 417-4750 Building 417-4815 T:Forms/Building Division/Building Permit THE0R� NGT LUS For City Use CITY OF �1 JDate mit# r /f W A s H ! N G T o N, U. S. Received: 321 E 5th Street e Approved Port Angeles,WA 9836 P:360-417-4817 F:360-417-4711 Email:permits@cityofpa.us � �'��BUILDING PERMICATION fi,-- 15-MA--15110-1V--410 Project Address: Iii Phone: Primag Contact: Email: Name / Phone V jeProperty Mailina Address Email Owner City State Z' Name Phone Contractor Addres Email Information city State � Zip Contractor License# Exp.Date: Legal Description: Zoning: Tax Parcel# Project Value: (materials and labor) Residential Commercial ❑ Industrial ❑ Public ❑ Permit Demolition ❑ Fire ❑ Repair ❑ Reroof(tear off/lay over) ❑ Classification For the following, fill out both pages of permit application: (check New Construction lia Exterior Remodel ❑ Addition ❑ Tenant Improvement ❑ appropriate) Mechanical ❑ Plumbing ❑ Other ❑ Fire Sprinkler System Proposed Irrigation System Proposed orProposed Bathrooms Proposed Bedrooms or Existing? Yes 0 No Existing? Yes 0 No ®-- In addition to standard hard copy submittals please send a PDF copy of all Stormwater plans and Engineering to www.sto rmwat e r @ c ityo fp a.u s Project Description &LA 1.2C�� Z� Is project in a Flood Zone: Yes 0 Noil--Flood Zone Type: If in a Flood Zone,what is the value of the structure before proposed improvement? $ I have read and completed the application and know it to be true and correct. I am authorized to apply for this permit and understand that it is my responsibility to determine what permits are required and to obtain permits prior to work. I understand that plan review fees are not refundable after review has occurred. I understand that I will forfeit review fees if I withdraw the application before the permit is issued. I understand that if the permit is not picked u /issued within 18o days of submittal the application P Y will be considered abandoned and the fees will be forfeited. � / /l,5 C"ei-5� --� 6 -- Date Print Name Si ature Residential Structures Existing Proposed Construction For Office Use Area Descriptions(SQ FT) Floor area Floor area $Value new area Basement First Floor 2—(e Second Floor Covered Deck/Porch/Entry Deck(over 30"or a° floor) C7 P Garage Carport Other(describe) Area Totals Cj Commercial Structures Area Descriptions(SQ FT) Existing Proposed Construction For Office Use Floor area Floor area $Value new area Existing Structure(s) Proposed Addition Tenant Improvement? Other work(describe) Site Area Totals Lot/Site Coverage Calculations Lot Size(sq ft) Lot Coverage(sq ft)foot print of %Lot Coverage(Total lot cov_lot size) Max Bldg Height Q(�� all structures s ft Site Coverage(Sq Ft of all impervious) %of Site Covera a(to al site cov_lot size) MechanicarFixiures Indicate how many of each type of fixture to be installed or relocated as part of this project. Air Handler Size: # Haz/Non-Haz Piping Outlets: Appliance Exhaust Fan # Heater(Suspended,Floor,Recessed wall) # Boiler/Compress :. Size: # Heating/Cooling appliance # re air/alteration Evaporative Cobler(attached,not # Pellet Stove/Wood-burning/Gas # ortable) Fireplace/Gas Stove/Gas Cook Stove/Misc. Fuel Gas Piping #of Outlets: Ventilation Fan,single duct # Furnace/Heat Pump/ Size: # Ventilation System # Forced Air Unit Plumbing Fixtures Indicate how many of each type of fixture to be installed or relocated Plumbing Traps # Water Heater # Plumbing Vent piping # 47p Medical gas piping #of Outlets: Water Line # Fuel gas piping #of Outlets: Sewer Line # Industrial waste pretreatment interceptor Grease Trap) Size Other(describe): T:\BUILDING\APPLICATION FORMS\Current BP Application\Building Permit 4-17-13.docx /S Baal !! a_ b � '2 J7 wi w1 ` ry 2 Ho c� O ��y to G u 9 / � / •r. G.. ' ..'I� �to l - ' ( 20,0 Lo T 12, aDfl�- lf7F CDVP9 Ei e bit 000 SLOP P- up 2(v�84% e I' Prescriptive Energy Code Compliance for All Climate Zones in Washington Projgct Information Contact Information Drafting.Solutions , W 15th'iale -- PO,Box,1246 .: Port Angeles, WA 98363 Port Angeles, WA 98362 This project will use the;requirements of the Prescriptive Path below and incorporate the the minimum vafae§ listed.In addition,based on the size of the structure,the appropriate number of additional credits.are checked as chosen by the permit applicant. Authorized Representative Date . -C N :�,� A11 jCl�mate Zones ,,u R-Value' U-Factora Fenestration U-Factorb n/a 0.30 Skylight U-Factor n/a 0.50 Glazed Fenestration SHGC°'e n/a n/a Ceiling 49 0.026 Wood Frame WallgX1 21 int 0.056 Mass Wall R-Value' 21/21h 0.056 Floor.. 309 0.029 Below Grade Wall`,k 10/15/21 int+TB 0.042 Slab°.R-Value&Depth 10, 2 ft n/a "Table R402.1.1 and Table R402.1.3 Footnotes included on Page 2. Each dwelling unit in one and two-family dwellings and townhouses,as defined in Section 101.2 of the International Residential Code shall comply with sufficient options from Table R406.2 so as to achieve the following minimum number of credits: 01.Small Dwelling Unit: 0.5 points Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration area. Additions to existing building that are less than 750 square feet of heated floor area. ❑2. Medium Dwelling Unit: 1.5 points All dwelling units that are not included in#1 or#3, including additions over 750 square feet. F-1 3. Large Dwelling Unit: 2.5 points Dwelling units exceeding 5000 square feet of conditioned floor area. Table R406.2 Summary Option Description Credit(s) 1 a . Efficient Building Envelope 1 a. 0.5 ❑ lb Efficient Building Envelope 1 b 1.0 ❑ 1c . Efficient Building Envelope 1 c 2.0 ❑. 2a Air Leakage Control and Efficient Ventilation 2a 0.5 0 0.5 2b Air Leakage Control and Efficient Ventilation 2b 1.0 ❑ 26 Air Leakage Control and Efficient Ventilation 2c 1.5 ❑ 36 High Efficiency HVAC 3a 0.5 ❑ 3b High Efficiency HVAC 3b 1.0 ❑ 3c High Efficiency HVAC 36 2.0 ❑ 3d High Efficiency HVAC 3d 1.0 ❑ 4 High Efficiency HVAC Distribution System 1.0 ❑ 5a Efficient Water Heating 0.5 ❑ 5b Efficient Water Heating 1.5 [] 6 Renewable Electric Energy 0.5 "1200 kwh 0.0 Total Credits 0.50 *Please refer to Table R406.2 for complete option descriptions http://www.energy.wsu.edu/Documents/2012%20Res%20Energy.pdf a 4y ` • qtr�.F � . ��°� '� + e x9t, 1119 �s M1.akc 'tx t �R R `� ��}' '�� •�b t-:�y�fr K.c # �� x y{�LAp ,y orf ' a� ''a��`.� `.6"x a'� ,(. "� � •. 4 ` s / s 4 R r i V s .b 6, m 14 Yrn'ii fA,, i®r ,� fie L �. � h '*F.. �` +•`r.'Y+G �9° T � ...�e � ,gyp i b �L • .,.AML ,�.• ,. .. .- F s '- 6 c ie