Loading...
HomeMy WebLinkAbout1851 Harborcrest Place Address: 1851 Harborcrest Place PREPARED 6/20/14, 12:58:13 INSPECTION TICKET PAGE 1 CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 6/20/14 ------------------------------------------------------------------------------------------------ ADDRESS . : 1851 HARBORCREST PL SUBDIV: CONTRACTOR : PHONE OWNER BIGBIE JAME R II PHONE PARCEL 06-30-00-9-6-0057-0000- APPL NUMBER: 14-00000408 RES REPAIR ------------------------------------------------------------------------------------------------ PERMIT: BPR 00 BUILDING PERMIT - "SIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS -------------------------- -------------------------------------------------------------------- BL99 01 6/20/14 L BLDG FINAL June 19, 2014 9:38:14 AM pbarthol. James460-8555 ------------------------ ------------ COMMENTS AND NOTES I CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY&ECONOMIC DEVELOPMENT- BUILDING DIVISION 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Application Number . . . . . 14-00000408 Date 4/09/14 ts Application pin number . . . 821696 Property Address . . . . . . 1851 HARBORCREST PL ASSESSOR PARCEL NUMBER: 06-30-00-9-6-0057-0000- REPORT SALES TAX Application type description RES REPAIR Subdivision Name . . . . . . on your state excise tax form Property Use . . . . . . . . to the City of Port Angeles Property Zoning . . . . . . . RS7 RESDNTL SINGLE FAMILY Application valuation . . . . 5600 Location Code 0502) ---------------------------------------------------------------------------- Application desc Repair deck ----- --------------------------------- ----------------------- OwnerContractor ------------------------ ------------------------ BIGBIE JAME R II OWNER 1851 HARBOR CREST PORT ANGELES WA 983629032 Permit . . . . . . BUILDING PERMIT -RESIDENTIAL Additional desc REPAIR DECK Permit Fee . . . . 151.75 Plan Check Fee 98.64 Issue Date 4/09/14 Valuation . . . . 5600 Expiration Date 10/06/14 Qty Unit Charge Per Extension BASE FEE 95.75 4.00 14.0000 THOU BL-2001-25K (14 PER K) 56.00 ---------------------------------------------------------------------------- Special Notes and Comments 1f. April 9, 2014 11:05:23 AM sroberds. The proposal will result in a second floor deck - 326 sq.ft. in area. Lot cov is 19W. No land use issues anticipated. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE SURCHARGE 4.50 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 151.75 151.75 .00 .00 Plan Check Total 98.64 98.64 "' .00 .00 Other Fee Total 4.50 4.50 .00 .00 Grand Total 254.89 254.89 .00 .00 Separate Permits are required forelectrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of PeNstir ate int Name Si nature of Contractor or Authorized Agent Signature of Owner(if owner is builder) CO :Fo s/Building Division/Building Permit BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS— Building Inspections 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION: Footings Stemwall Foundation Drainage/Downspouts Piers Post Holes(Pole Bldgs.) PLUMBING: Under Floor/Slab Rough-in Water Line Meter to Bldg) Gas Line Back Flow/Water FINAL Date Accepted b AIR SEAL: Walls Ceiling FRAMING: Joists/Girders/Under Floor Shear Wall/Hold Downs Walls/Roof/Ceiling Drywall Interior Braced Panel Only) T-Bar INSULATION: Slab Wall/Floor/Ceiling MECHANICAL: Heat Pum /Furnace/FAU/Ducts Rough-in Gas Line Wood Stove/Pellet/Chimney Commercial Hood/Ducts FINAL Date Accepted b MANUFACTURED HOMES: Footing/Slab Blocking&Hold Downs Skirting PLANNING DEPT. Separate Permit#s SEPA: Parkin /Lighting ESA: Landscaping SHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE Inspection Type Date Accepted By Electrical 417-4735 Construction-R.W. PW I Engineering 417-4831 Fire 417-4653 Planning 417-4750 Building 417-4815 T:Forms/Building Division/Building Permit THE ,ORS-+ �T �T E` For City Use CITY-OF 1 1�! L �? W A S H I N G T O N U . S. qor 3 �� Permit# Date Received: 7 1 OLy 321 E 5th Street Date Approved Port Angeles,WA 9836 4 P:360-417-4817 F:360-417-4711 + `• Email:permits@cityoofpa.us BUILDING PERMIT APPLICATION Project Address: /,�,5"� ,Ff ; •S'i �DTl$CC.F--.S 9P3(®2. Phone: -66 a a S S5_ Primary Contact: Email: J�- �,�. l �, d✓ �—,c .� Nann i� 61I 6 1'& � Phone.30 0 t(vD Property Mailin Add res L Email Owner l l ,rl? rl C��t . - ��� 0,K6 11- P : 0,� Ci State i K)A- Name Phone Contractor Address Email Information city State zip Contractor License# Exp.Date: Legal Description: Zoning: Tax Parcel# Project Value: materials and labor) LoT I s; �Q1,_3,0MQ1,0Q6-70QW $ Residential I- Commercial ❑ Industrial ❑ Public ❑ Permit Demolition ❑ Fire ❑ Repair A Reroof(tear off/lay over) ❑ Classification For the following,fill out both pages of permit application: (check New Construction ❑ Exterior Remodel ❑ Addition ❑ Tenant Improvement ❑ appropriate) Mechanical ❑ Plumbing ❑ Other ❑ Will a fire sprinkler system be installed Irrigation System? Proposed Bathrooms Proposed Bedrooms or modified? Yes ❑ No ❑ Yes ❑ No ❑ Project Description Y•. t �1 d s Is propeect in a Flood Zone: Yes ❑ No® Flood Zone" , Type: If in,a`Flood Zone, what is the value of the structure before proptisgd improvement? $ I have read and completed the application and know it to be true and correct. I am authorized to apply for this permit and understand that it is my responsibility to determine what permits are required and to obtain`permits prior to work. I understand that plan reviewf'eies°are not refundable after review has occurred. I understand that I will forfeit review fees if I witWd a­f the application before the permit is issued. .I understand that if the permit is not picked up/issue&within i8o days of submittal,the application will be cohsfdered abandoned and the fees will be forfeited.' lie - � Date Pri Name Si attire "� Residential Structures For Office Use Area Description(SQ FT) Existing Proposed ss value Basement o. I First Floor Second Floor Covered Deck/Porch/Entry oD n Deck(over 30,�or z ,floor) Garage r C Carport Other(describe) •r� C�Ail ®o N Area Totals o5� 401* —3tw Commercial Structures Proposed For Office Use Area Descriptions(SQ FT) Existing Proposed ss Value Existing Structure (s) Proposed Addition Tenant Improvement? Other work(describe) Site Area Totals Lot/Site Coverage Calculations Lot Size(sq ft) Lot Coverage(so ft) %Lot Coverage(Total lot coverage_lot size) S o Site Coverage(Sq Ft of all impervious) %of Site Coverage(total site coverage_lot size) Mechanical Fixtures Indicate how many of each type of fixture to be installed or relocated as part of this project. Air Handler Size: # ,j Haz/Non-Haz Piping Outlets: Appliance Exhaust Fan # N Heater(Suspended,Floor,Recessed wall) # Boiler/Compressor Size: # a ` Heating/Cooling appliance # � repair/alteration Evaporative Cooler(attached,not # •f Pellet Stove/Wood-burning/Gas # A portable) Fireplace/Gas Stove/Gas Cook Stove/Misc. Fuel Gas Piping #of Q t ets: Ventilation Fan,single duct # AJ r' Furnace/Heat Pump/ Size: # �l Ventilation System #N Forced Air Unit Plumbing Fixtures Indicate how many of each type of fixture to be installed or relocated Plumbing Traps # Fuel gas piping #of Outlets: Water Heater # Medical gas piping #of Outlets: Water Line # N n Plumbing Vent piping # 1 J Sewer Line #,�/ Industrial waste pretreatment interceptor Grease Trap) Size IJ Other(describe): T:\BUILDING\APPLICATION FORMS\Current BP Application\Building Permit 4-17-13.docx M x PsP `x o- ' aay� W k 9 T II4 •� bra �P. O >r ,. to h S' is r. w N � ri (� Pak vSf3 F; CCV _,° � � Proposed new deck 16' x 20' 16 20= All framing using pressure - treated wood. Decking to be 101 either composite or 5/4 cedar. t' 910 Const.ucY+on flans rr�� CITY OF PORT ANGELES-- #erm -non these plans,s ^" L The Issuance of this p [` offici e ` cat ons and other d '`F o ,n of errors in sa rea;te reo. `3the•corr ea,e, roe=. and other data or fron preventii sp on ti;ereunder v+hen n �Q, uu1lding operations L,-.',Ig carried �� ✓ o ?; s air of this juriio ,ter ._ of aN codes 4 .:n `�+'� 0 es By CPO ,v 5%q V4V 01 _ Existing concrete pad pC'\_ L � � H . wn,.. IMF 1= RAW 'M E a'ng deck out!ine v P ° SANu'`�� � �.� �� `i.'"S y y�/y9��'m /j 6 •= f �fr h Q•��t'L` s �����Y. ` '� x h c i I 00 Of ,y. c - ;, Way, Ow - gp _ / Existln^St91(._ 1 L ..-ad !"i'1£2 ls, fl, a 1 A �vBktirg 4"concrete pad QX­ nqn r A & ON M •r g . �c— LJLJ Ledger board backed with flashing and attached at 8" intervals alternating top and bottom using 5/16 x 6" construction screws and washers. 301-sts hung with hanger braeke nailed or screwed to ledger boa and joists. rEyR ]oists blocked mid point z � �, sF �r .:� ���t'k,� �.� rte. ,, �,�.,.., *•a �'� � p'�;,,. "��P. E a ,. _., ,..,9.R.c• ..,t,..��k,w,�.1'. ' f.3a..a.,e�... F, ....._,,5 _ .,. . .6, .•,,,r a, ,..pr .,... ......,.... _ • .._ ,xxx.x. ,._ ._...,� .�.,,.,,»,Ma. .c ....,,, a.y/y a....a.,s,,.,,r„< f 4 ,� „� �u ?C'” „f v; AI �I,y i MER WE-, 4 x c s lop rail is 2x6, baluste spaced at 4" on center, bottom rail 4" off Example f balusters and rails deckin j surface. 4' 9 3/4" i d ost spacing 6' or less \S O 110