HomeMy WebLinkAbout235 Forest Avenue Address: 235 Forest Avenue PREPARED 9/13/16, 9:06:04 INSPECTION TICKET PAGE 13 CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 9/13/16 ------------------------------------------------------------------------------------------------ ADDRESS . : 235 FOREST AVE SUBDIV: CONTRACTOR ROMERO CONTRACTING, LLC PHONE (360) 461-7402 OWNER DAVIDSON RICHARD V PHONE PARCEL 06-30-09-5-8-0016-0000- APPL NUMBER: 16-00001300 RE-ROOF ----------------------------------------------------------------------------------------------7- PERMIT: BNOP 00 BUILDING PERMIT - NO PR FEE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ BL99 01 9/13/16 BLDG FINAL September 13, 2016 8:54:29 AM jlierly. Mike Romero --------------------- ------------ COMMENTS AND NOTES -------------------------------------- CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT- BUILDING DIVISION Off 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Application Number . . . . . 16-00001300 Date 8/30/16 Application pin number . . . 039000 Property Address . . . . . . 235 FOREST AVE REPORT SALES TAX ASSESSOR PARCEL NUMBER: 06-30-09-5-8-0016-0000- Application type description RE-ROOF on your state excise tax form Subdivision Name . . . . . . Property Use . . . . . . . . to the City of Port Angeles Property Zoning . . . . . . . RS7 RESDNTL SINGLE FAMILY (Location Code 0502) Application valuation . . . . 9000 --------------------------------------------------------------------------- Application desc TEAR OFF AND PUT DOWN 30 YR COMP ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ DAVIDSON RICHARD V ROMERO CONTRACTING, LLC 235 FORREST AVE 2321 S LINCOLN ST PORT ANGELES WA 98362251,7 PORT.ANGELES WA 98362 (360) 461-7402 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT NO PR FEE Additional desc Permit Fee . . . . 193.75 Plan Check Fee .00 Issue Date . . . . 8/30/16 Valuation . . . . 9000 Expiration Date 2/26/17 Qty Unit Charge Per Extension BASE FEE 95.75 7.00 14.0000 THOU BL-2001-25K (14 PER K) 98.00 -------- ------------------------------------------------------------------- Va Other Fees . . . . . . . . . STATE SURCHARGE 4.50 --- ------- ------- ---- -------- --- -- -----Fee-summary--------Charged--------Paid-------Credited-------Due--------- ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 193.75 193.75 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 4.50 4.50 .00 .00 Grand Total 198.25 198.25 .00 .00 44 Separate Permits are required forelectrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced, or if required inspections have not been requested within ISO days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to gi I ve authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. 3D Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder) T:Forms/Building Division/Building Permit BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS— Building Inspections 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION: Footings Stemwall Foundation Drainage/Downspouts Piers Post Holes(Pole Bldgs.) PLUMBING: Under Floor/Slab Rough-In Water Line(Meter to Bldg) Gas Line Back Flow/Water AIR SEAL: Walls Ceiling FRAMING: Joists/Girders/Under Floor ar Wall/Hold Downs Walls/Roof/Ceiling Drywall(Interior Braced Panel Only) T-Bar INSULATION: Slab Wall/Floor/Ceiling MECHANICAL: Heat Pump/Furnace/FAU/Ducts Rough-in Gas Line Wood Stove/Pellet/Chimney Commercial Hood/Ducts MANUFACTURED HOMES: Footing/Slab Blocking&Hold Downs ISkirting PLANNING DEPT. Separate Permit#s SEPA: Parking/Lighting ESA: Landscaping SHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY1 USE Inspection Type Date Accepted By Electrical 417-4735 Construction - R.W. PW I Engineering 417-4831 Fire 417-4653 Planning 417-4750 Building 417-4815 THE "0 For City Use CiTY OF t JL -N G LE$� Permit# It- .1300 W A S H I N G T 0 N, U. S. Date Received: t(V 3 2 1 E 51h Street Date Approved FL 7b - ( L Port Angeles,WA 9836 P:360-417-4817 F:36o-417-471i Email:permitsOciiyoWa.us BUILDING PERMIT APPLICATION Project Address: 5- ro 11'4.S, �- Phone: uo 4(e,/P 7q or 2! Primary Contact: XCIA4elo Email: Name 5"Ite,)� 4,m e./c; Phone '3 (60 5'tlp 5- 70 2-JI -property Mailing Address Email Owner 7 Ffeb&awbe 4.�' City r-'01'4 9?'3 State Zip Name Phone A&e&-o Contractor Address Email -Information City r 9a,�u z State WA zip 444W Contractor License#__C� 5, �-& ,qgExp.Date: P 7 Legal Description: Zoning: Tax Parcel 'Va� Project lue: (materials and labor) $ q- 000 Residential 1B Commercial El Industrial 11 Public El Demolition El Fire 0 Repair Nh- Reroof Ctea Permit _r ophy over) 11 Classification For the following,fill out both pages of permit application: (check New Construction 1:1 Exterior Remodel 11 Addition . 0 Tenant Improvement 11 appropriate) Mechanical 11 Plumbing 0 Other El roposed Bath Proposed Bedrooms or Existing? Yes E3 No E3 Existing? Yes [3 No E3 Fire Sprinkler System Proposed I Irrigation System Proposed or In addition to standard hard copy submittals please send a PDF copy of all Stormwater plans and Engineering to www.storm3yg1er@cityof_pa.us Project Description Xz_ /-CPO, Is project in a Flood Zone: Yes 0 Noa'Flood Zone Type: If in a Flood Zone, what is the value of the structure before proposed improvement? $ I have read and completed the application and know it to be true and correct. I am authorized to apply for this permit and understand that it is my responsibility to determine what permits are required and to obtain permits prior to work. I understand that plan review fees are not refundable after review has occurred. I understand that.1 will forfeit review fees if I withdraw the application before the permit is issued. I understand that if the permit is not picked up/issued within iL8o days of submittal,the application will be considered abandoned and the fees will be forfeited. �Lu'r 30 Date Print Name Signature Residential Structures Existing Proposed Construction For Office Use Area Descriptions(SQ FT) Floor area Floor area $Value new area Basement First Floor Second Floor Covered Deck/Porch/Entry Deck(over 30"Or 2'd Poor) Garage Carport Other(describe) Area Totals Commercial Structures, Area Descriptions(SQ FT) Existing Proposed Construction For Office Use Floor area Floor area $Value new are Existing Structure(s) Proposed Addition Tenant Improvement? Other work(describe) Site Area Totals Lot/Site Coverage Calculations Lot Size(sq ft) Lot Coverage:(sq ft)foot print of %Lot Coverage(Total lot cov lot size) Max Bldg Height all 7-�' structures sq ft Site Coverage(Sq Ft of all impervious) %of Site Coverage(total site cov lot size) Mechanical Fixtures Indicate how man of each type of re to be installed or relocated as part of this project. Air Handler Size: # Haz/Non-Haz Piping Outlets: Appliance Exhaust Fan # Heater(Suspended,Floor,Recessed wall) # # Heating/Cooling appliance # Boiler/CompressW-� repair/alteration Evaporative Cooler(attached,not # Pellet Stove/Wood-burning/Gas # portable) Fireplace/Gas Stove/Gas Cook Stove/Misc. Fuel Gas Piping #of Outlets: Ventilation Fan,single duct # Furnace/Heat Pump/ Size: # Ventilation System # Forced Air Unit Plumbing Fixtures Indicate how many of each type of fixtu e to be installed or relocated Plumbing Traps # Water Heater # Plumbing Vent piping # Medical gas piping #of Outlets: Water Line # Fuel gas piping #of Outlets: Sewer Line # Industrial waste pretreatment interceptor(Grease Trap) Size Other(describe): T:\Forms\2015 CED Form Updates\Building&Permitting\BP\Building Permit 20150415.docx Application Number . . . . . 22-00000925 Date 7/26/22 Application pin number . . . 536250 Property Address . . . . . . 235 FOREST AVE ASSESSOR PARCEL NUMBER: 06-30-09-5-8-0016-0000- Application type description ELECTRICAL ONLY Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . RS7 RESDNTL SINGLE FAMILY Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc PV system ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ CONSTANCE PANIKE TTE SOLGEN POWER LLC 235 FORREST AVE 5715 BEDFORD STREET PORT ANGELES WA 983622517 PASCO WA 99301 (509) 931-1663 ---------------------------------------------------------------------------- Permit . . . . . . ELECTRICAL ALTER RESIDENTIAL Additional desc . . Permit Fee . . . . 188.00 Plan Check Fee . . .00 Issue Date . . . . 7/26/22 Valuation . . . . 0 Expiration Date . . 1/22/23 Qty Unit Charge Per Extension 1.00 5.0000 ECH EL-BRANCH CIRCUIT W/FEEDER 5.00 1.00 120.0000 ECH EL-0-200 SRV FEEDER 120.00 1.00 63.0000 ECH EL-R- BRANCH CIR WO/ SER FEED 63.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 188.00 188.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 188.00 188.00 .00 .00 Public Works and Utilities Department 321 E. 5th Street, Port Angeles, WA 98362 360.417.4735 | www.cityofpa.us | electricalpermits@cityofpa.us EL1-2 SF 1 - 2 SINGLE-FAMILY ELECTRICAL PERMIT APPLICATION Project Address: Project Description: □Single-Family Residential □ Duplex / ARU Building Square footage: OWNER INFORMATION Name: Email: Mailing Address: Phone: ELECTRICAL CONTRACTOR INFORMATION Name: License: Mailing Address: Expiration Date: Email: Phone: PROJECT DETAILS Item Unit Charge Quantity Total (Quantity x Unit Charge) Service/Feeder 200 Amp.$120.00 $ Service/Feeder 201-400 Amp.$146.00 $ Service/Feeder 401-600 Amp.$205.00 $ Service/Feeder 601-1000 Amp.$262.00 $ Service/Feeder over 1000 Amp.$373.00 $ Branch Circuit W/ Service Feeder $5.00 $ Branch Circuit W/O Service Feeder $63.00 $ Each Additional Branch Circuit $5.00 $ Branch Circuits 1-4 $75.00 $ Temp. Service/Feeder 200 Amp.$93.00 $ Temp. Service/Feeder 201-400 Amp.$110.00 $ Temp. Service/Feeder 401-600 Amp.$149.00 $ Temp. Service/Feeder 601-1000 Amp.$168.00 $ Portal to Portal Hourly $96.00 $ Signal Circuit/Limited Energy - 1&2 DU.$64.00 $ Manufactured Home Connection $120.00 $ Renewable Elec. Energy: 5KVA System or less $102.00 $ Thermostat (Note: $5 for each additional)$56.00 $ First 1300 Square Feet $120.00 $ Each Additional 500 square feet``$40.00 $ Each Outbuilding / Detached Garage $74.00 $ Each Swimming Pool / Hot Tub $110.00 $ TOTAL $ Owner as defined by RCW.19.28.261: (1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is required to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection. After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I am making the electrical installation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296- 46B, The City of Port Angeles Municipal Code, and Utility Specifications and PAMC 14.05.050 regarding Electrical Permit Applications. Date Print Name Signature (□Owner □Electrical Contractor / Administrator)Permit #: New Construction Only [Electrical Permit Applications may be submitted to City Hall or electricalpermits@cityofpa.us or faxed to 360.417.4711] 1 PREPARED 7/25/22,10:06:39 PAYMENT DUE CITY OF PORT ANGELES PROGRAM BP820L --------------------------------------------------------------------------- APPLICATION NUMBER:22-00000925 235 FOREST AVE FEE DESCRIPTION AMOUNT DUE --------------------------------------------------------------------------- ELECTRICAL ALTER RESIDENTIAL 188.00 TOTAL DUE 188.00 Please present reciept to the cashier with full payment Constance Panike235 W Forest Ave, Port Angeles, WA 98362DRAWN BY:DATE:17/06/2022IJADESIGNSOLGEN POWER5100 ELM RD,PASCO, WA 99301P: 509-931-16631PAGE #PV 1ABCDEFGH12345 54321CUSTOMDRAWING SCALE:GENERAL NOTES1.PRIOR TO THE COMMENCEMENT OF ANYWORK, THE CONTRACTOR SHALL NOTIFYTHE DESIGNER OF ANY DISCREPANCIESWITH THE DESIGN IN ANY CAPACITY.ESPECIALLY RECOMMENDATIONS, CODES,OR REGULATIONS & RULES OF THEAUTHORITY HAVING JURISDICTION, WHICHSUPERSEDED THE NEC.2.ALL DIMENSIONS TO BE VERIFIED BYCONTRACTOR PRIOR TO COMMENCEMENTOF WORK.3.CONTRACTOR IS RESPONSIBLE FOR ALLSAFETY PRECAUTIONS, OSHAREQUIREMENTS ETC. FOR THE SITE,INCLUDING EXISTING SITE HAZARDS.4.SYSTEM IS GRID INTERACTIVE/INTERTIEDVIA A UL LISTED POWER-CONDITIONINGINVERTER.5.SYSTEM HAS NO ENERGY STORAGE OFANY KIND, OR UPS.6.ALL SOLAR MOUNTING FRAMEWORK TOBE GROUNDED.7.FOLLOW MANUFACTURERS SUGGESTEDINSTALLATION PRACTICES AND WIRINGSPECIFICATIONS.8.ALL WORK TO BE IN COMPLIANCE WITHTHE INTERNATIONAL BUILDING CODES.(IBC)9.ALL ELECTRICAL WORK TO BE INCOMPLIANCE WITH THE NATIONALELECTRIC CODE (NEC).ELECTRICAL NOTES1.WHERE ALL TERMINALS OF THEDISCONNECTING MEANS MAY BEENERGIZED IN THE OPEN POSITION, ASIGN WILL BE PROVIDED WARNING OFTHE HAZARDS. (PER ART. 690.17)2.EACH UNGROUNDED CONDUCTOR OFTHE MULTIWIRE BRANCH CIRCUIT WILLBE IDENTIFIED BY PHASE AND SYSTEM.(PER ART. 210.5)3.A NATIONALLY RECOGNIZED TESTINGLABORATORY SHALL LIST ALLEQUIPMENT IN COMPLIANCE WITHARTICLE 110.3.4.ALL WIRES SHALL BE PROVIDED WITHSTRAIN RELIEF AT ALL ENTRY POINTSINTO BOXES AS REQUIRED BY UL LISTING5.MODULE FRAMES SHALL BE GROUNDEDAT THE UL-LISTED LOCATION PROVIDEDBY THE MANUFACTURER USINGUL-LISTED GROUNDING HARDWARE.6.MODULE FRAMES, RAIL, AND POSTSSHALL BE BONDED WITH EQUIPMENTGROUND CONDUCTORS AND GROUNDEDAT THE MAIN ELECTRICAL PANEL.7.THE DC GROUNDING ELECTRODECONDUCTOR SHALL BE SIZEDACCORDING TO ARTICLE 250.166B &690.47.AERIAL VIEWRESIDENCE PHOTOSHEET INDEXPV 1 COVER PAGEPV 2 SITE PLANPV 3 ELECTRICAL DIAGRAMPV 6 PLACARDCONFIDENTIAL - THE INFORMATION CONTAINEDIN THIS PACKET AND SUBSEQUENT CUTSHEETSSHALL NOT BE USED FOR THE BENEFIT OFANYONE OUTSIDE SOLGEN POWER. NEITHERSHALL IT BE DISCLOSED TO OTHERS OUTSIDETHE RECIPIENT'S ORGANIZATION, EXCEPT INCONNECTION WITH THE SALE AND USE OF THERESPECTIVE EQUIPMENT, WITHOUT WRITTENCONSENT FROM SOLGEN POWER.CUT SHEETS ATTACHEDPV 4 CHIKO MOUNTINGPV 5 MOUNTING DIAGRAM NEWSINDEX:NUMBER OF MODULES:18MODULE TYPE:INVERTER:MODULESUTILITY METERMAIN SERVICESUNTECHSTP370S-B60/WNHBHoymiles Series23COMBINER BOX4124" O.C.2" x 8"RAFTER SPACING:RAFTER SIZE:SYSTEM SIZE DC:6.66kWSYSTEM SIZE AC:5.40kWAC DISCONNECT524" O.C.2" x 4"TRUSS SPACING:TRUSS SIZE:ROOF 1ROOF 21'-6"1'-6"1'-6"Constance Panike235 W Forest Ave, Port Angeles, WA 98362DRAWN BY:DATE:17/06/2022IJAABCDEFGH12345 54321DESIGN1PAGE #PV 211/128" = 1'-0"DRAWING SCALE:SOLGEN POWER5100 ELM RD,PASCO, WA 99301P: 509-931-1663CONFIDENTIAL - THE INFORMATION CONTAINEDIN THIS PACKET AND SUBSEQUENT CUTSHEETSSHALL NOT BE USED FOR THE BENEFIT OFANYONE OUTSIDE SOLGEN POWER. NEITHERSHALL IT BE DISCLOSED TO OTHERS OUTSIDETHE RECIPIENT'S ORGANIZATION, EXCEPT INCONNECTION WITH THE SALE AND USE OF THERESPECTIVE EQUIPMENT, WITHOUT WRITTENCONSENT FROM SOLGEN POWER.CIRCUIT 1CIRCUIT 2SOLAR OFFSET1COMP. SHINGLEWAC 51-54A-1204.2.1 IFC2018EXCEPTION 53ROOF AREA: 3180Ft2PV AREA: 353.27Ft2ROOF %: 11.11%ROOF 1ROOF 2452 (2)8 AWG(1)8 AWG EGC(2)8 AWG(1)8 AWG EGCMUTILITY METER (E)TO UTILITYGRID (E)200AMAIN SERVICEDISCONNECT (E)EXISTINGWIREMAIN SERVICE PANEL (E)(2)8 AWG(1)8 AWG EGC30A LOAD-SIDESOLAR OCPD(Opposite end of the main disconnecton the busbar - NEC 705.12(B)(3)(2)12 AWG(1)8 AWG EGC(2)12 AWG(1)8 AWG EGC20A OCPD NEW SOLAR 10A 2 POLE NEW SOLARCIRCUIT #1CIRCUIT #234121212 SUNTECH STP370S-B60/WNHBMODULESWITH HOYMILES HM-1200 MICROINVERTERS3412124 SUNTECH STP370S-B60/WNHB MODULESWITH HOYMILES HM-1200 MICROINVERTERS2 SUNTECH STP370S-B60/WNHBMODULESWITH HOYMILES HM-600 MICROINVERTERS(2 OF 2)(1 OF 2)Constance Panike235 W Forest Ave, Port Angeles, WA 98362DRAWN BY:DATE:17/06/2022IJAABCDEFGH12345 54321DESIGN1PAGE #PV 3NOT TO SCALEDRAWING SCALE:SOLGEN POWER5100 ELM RD,PASCO, WA 99301P: 509-931-1663CONFIDENTIAL - THE INFORMATION CONTAINEDIN THIS PACKET AND SUBSEQUENT CUTSHEETSSHALL NOT BE USED FOR THE BENEFIT OFANYONE OUTSIDE SOLGEN POWER. NEITHERSHALL IT BE DISCLOSED TO OTHERS OUTSIDETHE RECIPIENT'S ORGANIZATION, EXCEPT INCONNECTION WITH THE SALE AND USE OF THERESPECTIVE EQUIPMENT, WITHOUT WRITTENCONSENT FROM SOLGEN POWER.213NOTES:1.200A UTILITY METER GLOBE ONLY. (EXISTING)2.200A LOAD CENTER. (EXISTING)3.30A RATED NON-FUSED LOCKABLE AC DISCONNECT.(NEW)4.125A RATED COMBINER PANEL. (NEW)ALL CONDUIT SIZES ARE MINIMUM SIZESALL WIRE SIZES ARE FOR COPPER WIRE4COMBINER BOX PANEL SIZE CALCSNUMBER OFMODULESNOMINAL OUTPUTCURRENTTOTAL125%CIRCUIT #BREAKER SIZETOTALNUMBER OFMICROINVERTERSCOMBINEDTOTALMAX AC OPERATING CURRENT CALCS FOR HM-1200# OF MICROINVERTERSMAX OUTPUT CURRENTMAX AC OPERATING CURRENTX=MAX AC OPERATING CURRENT CALCS FOR HM-600# OF MICROINVERTERSMAX OUTPUT CURRENTMAX AC OPERATING CURRENTX=MAX AC OPERATINGCURRENT FOR HM-1200 & 600TOTALHM-1200HM-600+=412.46A22.46A5.0A2.46A20.00A20.00A2.46ALOAD CALCS - TOTAL AMPS AVAILABLEBUS RATING120%TOTALMAIN BREAKERX=-=MAX BREAKER SIZE200A1.2240200A40ABREAKER SIZE CALCSMAX AC OPERATING CURRENT125%TOTALBREAKER SIZE22.46Ax1.25x28.08A=30AX=12CIRCUIT 135.0A=x1.25==N/A15.00A18.75A20AX=2CIRCUIT 2 (1 of 2)1CIRCUIT 2 (2 of 2)X==412.46A5.0A=x1.25=3.08A=9.33Ax1.25=10A2.46A5.00A6.25ASLIM DOWN BREAKERSTO ALLOW FOR SOLARBREAKER CONNECTION Constance Panike235 W Forest Ave, Port Angeles, WA 98362DRAWN BY:DATE:17/06/2022IJADESIGN1PAGE #PV 4ABCDEFGH12345 54321STRUCTURAL NOTES:1.TOTAL WEIGHT (MODULE & RAIL): 828 LBS2.RAIL WEIGHT: 74 LBS3.MODULE WEIGHT: 754 LBS4.DISTRIBUTED WEIGHT: 2.41 PSFSOLGEN POWER5100 ELM RD,PASCO, WA 99301P: 509-931-1663CONFIDENTIAL - THE INFORMATION CONTAINEDIN THIS PACKET AND SUBSEQUENT CUTSHEETSSHALL NOT BE USED FOR THE BENEFIT OFANYONE OUTSIDE SOLGEN POWER. NEITHERSHALL IT BE DISCLOSED TO OTHERS OUTSIDETHE RECIPIENT'S ORGANIZATION, EXCEPT INCONNECTION WITH THE SALE AND USE OF THERESPECTIVE EQUIPMENT, WITHOUT WRITTENCONSENT FROM SOLGEN POWER.5'9"3'5"5'9"0.67"13.8'D4'Mid ClampEnd Clamp4'4'14.24'Grounding Lug6"1.4"ROOFINGSOLAR PANELCHIKO7# RailROOF TECHMINIL FOOTMount through roof sheathinginto existing rafters/trussesSS304 5mm x 60mmwood screws per RTmini manufacturer 33'-3"14'34'-9"14'Constance Panike235 W Forest Ave, Port Angeles, WA 98362DRAWN BY:DATE:17/06/2022IJAABCDEFGH12345 54321DESIGN1PAGE #PV 547/256" = 1'-0"DRAWING SCALE:STRUCTURAL NOTES:1.48" MAX SPAN OF RAIL TO DISTRIBUTE WEIGHTOVER SUPPORT OF TRUSSES2.MOUNTING FEET ARE IN APPROXIMATE LOCATION.3.MOUNTING FEET SHOULD BE STAGGERED ASSHOWN IN DIAGRAM2MOUNTING DIAGRAM1MOUNTING DIAGRAMSCALE: NOT TO SCALESOLGEN POWER5100 ELM RD,PASCO, WA 99301P: 509-931-1663CONFIDENTIAL - THE INFORMATION CONTAINEDIN THIS PACKET AND SUBSEQUENT CUTSHEETSSHALL NOT BE USED FOR THE BENEFIT OFANYONE OUTSIDE SOLGEN POWER. NEITHERSHALL IT BE DISCLOSED TO OTHERS OUTSIDETHE RECIPIENT'S ORGANIZATION, EXCEPT INCONNECTION WITH THE SALE AND USE OF THERESPECTIVE EQUIPMENT, WITHOUT WRITTENCONSENT FROM SOLGEN POWER.MOUNTING FEETPV MODULECHIKO #7 RAILROOF 1TILT:17°AZIMUTH:181°ROOF 2TILT:17°AZIMUTH:181°06/17/2022STRUCTURAL ONLY. NEWSConstance Panike235 W Forest Ave, Port Angeles, WA 98362DRAWN BY:DATE:17/06/2022IJADESIGN1PAGE #PV 6ABCDEFGH12345 54321SOLGEN POWER5100 ELM RD,PASCO, WA 99301P: 509-931-1663CONFIDENTIAL - THE INFORMATION CONTAINEDIN THIS PACKET AND SUBSEQUENT CUTSHEETSSHALL NOT BE USED FOR THE BENEFIT OFANYONE OUTSIDE SOLGEN POWER. NEITHERSHALL IT BE DISCLOSED TO OTHERS OUTSIDETHE RECIPIENT'S ORGANIZATION, EXCEPT INCONNECTION WITH THE SALE AND USE OF THERESPECTIVE EQUIPMENT, WITHOUT WRITTENCONSENT FROM SOLGEN POWER.PV DISCONNECTCAUTIONPOWER TO THIS BUILDING IS SUPPLIED FROM THEFOLLOWING SOURCES WITH DISCONNECTSLOCATED AS SHOWN:6"x6"235 W Forest Ave, Port Angeles, WA 98362SOLAR PV ARRAY WITHMICROINVERTERSROOF MOUNTEDMAIN SERVICE PANELUTILITY METER Power Output The Suntech IP68 rated junction box ensures an outstanding waterproof level, supports installations in all orientations and reduces stress on the cables. High reliable performance, low resistance connectors ensure maximum output for the highest energy production. • World-class manufacturer of crystalline silicon photovoltaic modules • Unrivaled manufacturing capacity and world-class technology • Rigorous quality control meeting the highest international standards: ISO 9001, ISO 14001 and ISO17025 • Regular independently checked production process from international accredited institute/company • Tested for harsh environments (salt mist, ammonia corrosion and sand blowing testing: IEC 61701, IEC 62716, DIN EN 60068-2-68)** • Long-term reliability tests • 2 x 100% EL inspection ensuring defect-free modules www.suntech-power.com ©Copyright 2020 Suntech Power Weak light PIDResistan t Features Extended wind and snow load tests Module certified to withstand extreme wind (3800 Pascal) and snow loads (5400 Pascal) * High PID resistant Advanced cell technology and qualified materials lead to high resistance to PID Withstanding harsh environment Reliable quality leads to a better sustainability even in harsh environment like desert, farm and coastline Excellent weak light performance More power output in weak light condition, such as haze, cloudy, and morning High power output Compared to 158.75 mm half- cell module,the power output can increase 25 - 30 Wp 3800Pa5400Pa 2% Suntech current sorting process System output maximized by reducing mismatch losses up to 2% with modules sorted & packaged by amperage Trust Suntech to Deliver Reliable Performance Over Time Industry-leading Warranty based on nominal power IP68 Rated Junction Box STPXXXS - B60/Wnhb 350-370 WattFull Black Series UL-STP-Full Black-NO3.01-Rev 2020 Special Cell Design The unique cell design leads to reduced electrodes resistance and smaller current, thus enables higher fill factor. Meanwhile, it can reduce losses of mismatch and cell wear, and increase total reflection. Industry leading linear warranty10 • 98% in the first year, thereafter, for years two (2) through twenty-five (25), 0.55% maximum decrease from MODULE’s nominal power output per year, ending with the 84.8% in the 25th year after the defined WARRANTY STARTING DATE.*** • 12-year product warranty • 25-year linear performance warranty 100% Warranted Power Output10 25 1 10 25 84.8% 98% 80% 90% 120 HALF-CELL ALL BLACK MONOFACIAL MODULE Certifications and standards: UL 61730 * Please refer to Suntech Standard Module Installation Manual for details. ** Please refer to Suntech Product Near-coast Installation Manual for details. *** Please refer to Suntech Product Warranty for details. IEC-STP-Vem-NO1.01-Rev 2014JP-STP-Wfhm-NO1.01-Rev 2018 www.suntech-power.com ©Copyright 2020 Suntech Power UL-STP-Full Black-NO3.01-Rev 2020 Information on how to install and operate this product is available in the installation instruction. All values indicated in this data sheet are subject to change without prior announcement. The specifications may vary slightly. All specifications are in accordance with standard EN 50380. Color differences of the modules relative to the figures as well as discolorations of/in the modules which do not impair their proper functioning are possible and do not constitute a deviation from the specification. NMOT STPXXXS-B60/Wnhb Maximum Power at NMOT (Pmax)278.2 W 274.3 W 270.7 W 266.8 W 263.3 W Optimum Operating Voltage (Vmp)32.0 V 31.8 V 31.6 V 31.5 V 31.3 V Optimum Operating Current (Imp)8.69 A 8.62 A 8.56 A 8.48 A 8.42 A Open Circuit Voltage (Voc)38.7 V 38.5 V 38.4 V 38.2 V 38.0 V Short Circuit Current (Isc)9.17 A 9.10 A 9.04 A 8.96 A 8.89 A NMOT: Irradiance 800 W/m2, ambient temperature 20 °C, AM=1.5, wind speed 1 m/s. STC STPXXXS-B60/Wnhb Maximum Power at STC (Pmax)370 W 365 W 360 W 355 W 350 W Optimum Operating Voltage (Vmp)34.3 V 34.1 V 33.9 V 33.7 V 33.5 V Optimum Operating Current (Imp)10.79 A 10.71 A 10.62 A 10.54 A 10.46 A Open Circuit Voltage (Voc)40.9 V 40.7 V 40.5 V 40.3 V 40.1 V Short Circuit Current (Isc)11.49 A 11.42 A 11.35 A 11.28 A 11.21 A Module Efficiency 20.3%20.0%19.7%19.5%19.2% Operating Module Temperature -40 °C to +85 °C Maximum System Voltage 1000 V DC (IEC) Maximum Series Fuse Rating 20 A Power Tolerance 0/+5 W STC: lrradiance 1000 W/m2, module temperature 25 °C, AM=1.5; Tolerance of Pmax is within +/- 3%. Electrical Characteristics Dealer information Nominal Module Operating Temperature (NMOT)42 ± 2 °C Temperature Coefficient of Pmax -0.36%/°C Temperature Coefficient of Voc -0.304%/°C Temperature Coefficient of Isc 0.050%/°C Temperature Characteristics Solar Cell Monocrystalline silicon 166 mm No. of Cells 120 (6 × 20) Dimensions 1756 × 1039 × 35 mm (69.1 × 40.9 × 1.4 inches) Weight 20.3 kgs (44.8 lbs.) Front Glass 3.2 mm (0.13 inches) tempered glass Frame Anodized aluminium alloy Junction Box IP68 rated (3 bypass diodes) Output Cables 4.0 mm2, Portrait: (-)350 mm and (+)160 mm in length Landscape: (-)1300 mm and (+)1300 mm in length or customized length Connectors MC4 compatible Mechanical Characteristics Container 20’ GP 40’ HC Pieces per pallet 31 31 Pallets per container 6 26 Pieces per container 186 806 Packaging box dimensions 1786 × 1130 × 1203 mm Packaging box weight 679 kg Packing Configuration Current-Voltage & Power-Voltage Curve (370S) 1000 W/m2 800 W/m2 600 W/m2 400 W/m2 200 W/m2 0 50 100 150 200 250 300 350 400 0 2 4 6 8 10 12 0 10 20 30 40 50Current (A)Power (W)Votage (V) abr5%cdefr5%gr5%42℃r2℃ (Pmax (Imp(Vmp(Isc(Voc(T ) ))))) Model NumberRated Maximum PowerOutput ToleranceCurrent at PmaxVoltage at PmaxShort-Circuit CurrentOpen-Circuit VoltageNominal Module Operating Temp. All technical data at standard test conditionAM=1.5 E=1000W/m2 Tc=25℃Hazardous electricity can shock, burnor cause death. Do not touch terminals. V.xx Made in China Wuxi Suntech Power Co.,Ltd.Add: No.16 Xinhua Road, Xinwu District Wuxi, JiangSu Province 214000 P. R. ChinaCustomer Service Hot Line: +86 400 8888 009 Fax:+86 510 8534 3321 Cell TechnologyApplicationMaximum System VoltageMaximum Series Fuse RatingWeightDimension mClass Aklij � Autodesk � � � � � � �� Autodesk � � � � � � �� Autodesk � � � � � � �� Autodesk � � � � � � � ® www.roof-tech.us info@roof-tech.us RT-MINI Self-flashing base for asphalt & metal roof-top PV mounting systems Dual bolt design: M8 or 5/16” for L-Foot & 1/4” for EMC 1/4” Hex Bolt upper channelEasy tapping screw guide M8 or 5/16” Hex Bolt bottom channel Flat lip for PV Cable clips RT-MINI is suitable for mounting any rail system with a conventional L-Foot. ICC ESR 3575 *OTUBMMBUJPO.BOVBM RT-MINI Flexible Flashing certified by the International Code Council (ICC) Components RT2-00-MINIBK MINI base : 20 ea. Screw : 40 ea. Extra RT-Butyl : 10 ea. RT-Butyl is Roof Tech s flexible flashing used in one million residential PV systems for the last 26 years. It is the first PV mounting system with Flexible Flashing certified by the ICC. Engineered to withstand wind speeds up to 180 mph and ground snow up to 90 psf. ICC ESR-3575 ASTM2140 testing UV testing (7500 hrs.) www.roof-tech.us info@roof-tech.us 10620 Treena Street, Suite 230, San Diego, CA 92131858.935.6064 Roof Tech Inc. Flexible Flashing 100% Waterproof Metal Flashing Retrofit Shedding water? Rafter installation Deck installation P.E. Stamped Letters available at www.roof-tech.us/support Optional item 5 x 60mm Mounting screw (RT2-04-SD5-60) : 100 ea./Bag 5/16” Hex bolt, washer & nut set (RT-04-BN30SL-US) : 100 ea./Bag RT-Butyl (RT2-04-BUTYLT) : 10 ea./BoxPatent #D822459S™ Dimensions in (mm)&BWF&BWFEngineered to ASTM D 1761 (Standard Test Methods for Mechanical Fasteners in Wood) TAS 100 A on metal and asphalt roof.        3FW AL Roof Hook 019 CHIKO L Feet matching to the Flashing,supplying the best waterproofing solution for Asphalt Shingles Roofs. Enables simple, fast and cost-effective installation High class anodized aluminium. Fasteners and rail nut configurated to save extra parts purchasing. 100% water proofing. PRODUCT LINE Item CK-FTH-211 Product Name CHIKO AL Roof Hook 211 ORDERING SPECIFICS Standard Packaging Dimensions Weight 16PCS/CTN 34X25X7CM 6KG www.chikolar.com/www.chikosolar.com Phone:86-21-59972267-801 Fax:86-21-59972938 ADVANTAGES TECHNICAL DATA Main Material Uplift P Wind Load Snow Load Hook Spacing Installation Site 6005-T5 & SUS304 N*Fvč N=3Ď Up to 60 M/S 1.4 KM/M2 Up to 2000mm Roman Tile Roof COMPONENT LIST MATERIAL AL Flashing AL L Feet 050 Nut SUS Bolt M8*25 SUS M8 Wahser Wooden Screw M8*90 Silicon Rubber QTY 01 01 01 01 02 01 01 85WARRANTY UL LISTED 7 RAIL CHIKO 7R aluminium rail is designed for roof mounting system, it could applied on all roof mount system. PRODUCT LINE Item CK-7R-2100 CK-7R-3200 CK-7R-4200 Product Name CHIKO 7 RAIL 2100MM CHIKO 7 RAIL 3200MM CHIKO 7 RAIL 4200MM TECHNICAL DATA Main Material Wind Velocity Xi=31918.082 mm4 Yi=81501.592 mm4 AL 6005-T5 Up to 60 M/S ORDERING SPECIFICS Standard Packaging Dimensions Weight 8 PCS/PKG 2100/3200/4200mm 15/22.8/30KG COMPONENT LIST WARRANTY MATERIAL Aluminium Rail QTY 01 www.chikolar.com/www.chikosolar.com Phone:86-21-59972267-801 Fax:86-21-59972938 Easy installation Highclass anodized Tilt- in nut Universal on roof mount system ADVANTAGES UL LISTED 7 RAIL SPLICE KIT CHIKO 7R aluminium rail splice kit is designed for 7R rail connection from back to position. The most simple and handy installation way. PRODUCT LINE Item CK-FT-SKA Product Name CHIKO 7 Rail Splice Kit TECHNICAL DATA Main Material Wind Load Snow Load AL 6005-T5 Up to 60 M/S 1.4 KM/M2 ORDERING SPECIFICS Standard Packaging Dimensions Weight 200 PCS/PKG 51X38X22CM 30KG www.chikolar.com/www.chikosolar.com Phone:86-21-59972267-801 Fax:86-21-59972938 200m m 45.7mm Easy installation Highclass anodized COMPONENT LIST MATERIAL Aluminium Rail Splice Kit SUS304 Bolt M8*25 Star Washer QTY 01 02 02 WARRANTYADVANTAGES UL LISTED Intergated Grounding Mid Clamp CHIKO end clamps is designed base on 7R rail to fix module on the end of rail, have founction of intergated grounding, 30mm to 50 mm thickness module are available. PRODUCT LINE Item CK-FTM-K30 CK-FTM-K33 CK-FTM-K35 CK-FTM-K38 CK-FTM-K40  Product Name CHIKO Intergated Grounding Mid Clamp 30mm CHIKO Intergated Grounding Mid Clamp 33mm CHIKO Intergated Grounding Mid Clamp 35mm CHIKO Intergated Grounding Mid Clamp 38mm CHIKO Intergated Grounding Mid Clamp 40mm COMPONENT LIST WARRANTY MATERIAL Mid Clamp SUS304 Bolt M8 050 SUS304 Nut Rivet Intergated Grounding Easy installation High class anodized Tilt- in nut TECHNICAL DATA Main Material AL 6005-T5 QTY 01 01 01 02 ORDERING SPECIFICS Standard Packaging Dimensions Weight 100 PCS/BOX 400PCS/CTN 50X38X20CM 26.8/27.5/28/28.6KG D=30/33/35/38/40/45/50 www.chikolar.com/www.chikousa.com Phone:86-21-59972267-801 Fax:86-21-59972938 ADVANTAGES UL LISTED Intergated Grounding End Clamp CHIKO end clamps is designed base on 7R rail to fix module on the end of rail, have founction of intergated grounding, 30mm to 50mm thickness module are available. Intergated Grounding Easy installation High class anodized Tilt- in nut ADVANTAGES UL LISTED PRODUCT LINE Item CK-FTE-K30 CK-FTE-K33 CK-FTE-K35 CK-FTE-K38 CK-FTE-K40 ... Product Name CHIKO Intergated Grounding End Clamp 30mm CHIKO Intergated Grounding End Clamp 33mm CHIKO Intergated Grounding End Clamp 35mm CHIKO Intergated Grounding End Clamp 38mm CHIKO Intergated Grounding End Clamp 40mm TECHNICAL DATA ORDERING SPECIFICS Standard Packaging Dimensions Weight 100 PCS/BOX 400PCS/CTN 50X38X20CM 22/24.5/25.5/26KG COMPONENT LIST WARRANTY MATERIAL End Clamp SUS304 Bolt M8*25 SUS304 Washer M8 050 SUS304 Nut Rivet QTY 01 01 01 01 01 Main Material AL 6005-T5 D=30/33/35/38/40/45/50 www.chikolar.com/www.chikousa.com Phone:86-21-59972267-801 Fax:86-21-59972938 5002148 Sense Energy Monitor Technical Specications Sense is a home energy monitoring device. It is used to measure current and voltage in the service mains and solar supply of your home. If installed outside, it must be kept dry and within specied temperature ranges. The Sense monitor should only be installed by a licensed electrician. Monitor (Monitor Model Nos. SM3, SM3S) Compatibility: 120VAC (90V-130V), 60 Hz Processor: 1 GHz ARM Wi-Fi: 2.4 GHz 802.11b/g/n Power Consumption: <5 watts, 0.1 amps Dimensions: 5 3/8” H x 2 5/8“ W x 1 1/4” D Weight: 220 g RH < 90%; Elevation < 3000 meters; Temperature: 0 - 50°C Current Transformers CAT III, 300V, 200A max May be used on uninsulated conductors Dimensions: 3 6/16" H x 2" W x 12/16" D Inside Diameter: 1” Cable length: 46” Power Cable 16 AWG (UL), THHN or THWN, 600V. Cable length: 14” Per UL requirements, the Sense energy monitor power cable itself is marked with all the required safety information, and compliance was verified as part of obtaining our safety certifications. It is jacketed with PVC to form a flexible power cord of UL type SVT, and marked as such. Certifications Certified to CSA STD C22.2 No. 61010-1 Conforms to UL STD 61010-1 Conforms to CAN ICES-3(B)/NMB-3(B) Open Energy For All Features Description Hoymiles 4-in-1 microinverter is one of the most cost-effective module-level solar solutions, as it can support up to 4 panels at once and maximize the PV production of your installation. With the maximum DC voltage of 60 V, Hoymiles microinverter is a PV Rapid Shutdown Equipment and conforms with NEC-2017 and NEC-2020 Article 690.12 and CEC-2021 Sec 64-218. All of the three models listed are equipped with reactive power control and are compliant with IEEE 1547, UL 1741 and CA Rule21. Microinverter Datasheet HM-1200N HM-1500N Region: North America V202108 © 2021 Hoymiles Power Electronics Inc. All rights reserved. hoymiles.com sales@hoymiles.com 01 02 03 Easy installation, just plug and play With Reactive Power Control, compliant with CA Rule 21 Compliant with U.S. NEC-2017&NEC-2020 690.12 rapid shutdown 05 04 External antenna for stronger communication with DTU High reliability, NEMA 6 (IP67) enclosure, 6000 V surge protection Model HM-1200N HM-1500N Input Data (DC) Commonly used module power (W)240 to 405+300 to 505+ Maximum input voltage (V)60 MPPT voltage range (V)16-60 Start-up voltage (V)22 Maximum input current (A)4 × 11.5 4 × 11.5 Output Data (AC) Peak output power (VA) 1260 1200 1500 1350 Maximum continuous output power (VA)1200 1109 1438 1246 Maximum continuous output current (A)5 5.33 5.99 5.99 Nominal output voltage/range (V)1 240/211-264 208/183-228 240/211-264 208/183-228 Nominal frequency/range (Hz)1 60/55-65 Power factor (adjustable)>0.99 default 0.8 leading…0.8 lagging Total harmonic distortion <3% Maximum units per branch2 3 3 2 2 Efficiency CEC peak efficiency 96.7% CEC weighted efficiency 96.5% Nominal MPPT efficiency 99.8% Nighttime power consumption (mW) <50 Mechanical Data Ambient temperature range (°C)-40 to +65 Dimensions (W × H × D mm)280 × 176 × 33 Weight (kg)3.75 Enclosure rating Outdoor-NEMA 6 (IP67) Cooling Natural convection – No fans Features Communication 2.4GHz Proprietary RF (Nordic) Monitoring S-Miles Cloud3 Warranty Up to 25 years Compliance UL 1741, IEEE 1547, UL 1741 SA (240 Vac), CA Rule 21 (240 Vac), CSA C22.2 No. 107.1-16, FCC Part 15B, FCC Part 15C PV Rapid Shutdown Conforms with NEC-2017 and NEC-2020 Article 690.12 and CEC-2021 Sec 64-218 Rapid Shutdown of PV Systems Technical Specifications © 2021 Hoymiles Power Electronics Inc. All rights reserved. *1 Nominal voltage/frequency range can vary depending on local requirements. *2 Refer to local requirements for exact number of microinverters per branch. *3 Hoymiles Monitoring System. Open Energy For All Features Description Hoymiles 2-in-1 microinverter can connect up to 2 panels at once and maximize the PV production of your installation. With the maximum DC voltage of 60 V, Hoymiles microinverter is a PV Rapid Shutdown Equipment and conforms with NEC-2017 and NEC-2020 Article 690.12 and CEC-2021 Sec 64-218. All of the three models listed are equipped with reactive power control and are compliant with IEEE 1547, UL 1741 and CA Rule21. Microinverter Datasheet HM-600N HM-700N HM-800N Region: North America V202108 © 2021 Hoymiles Power Electronics Inc. All rights reserved. hoymiles.com sales@hoymiles.com 01 02 03 Easy installation, just plug and play With Reactive Power Control, compliant with CA Rule 21 Compliant with U.S. NEC-2017&NEC-2020 690.12 rapid shutdown 05 04 External antenna for stronger communication with DTU High reliability, NEMA 6 (IP67) enclosure, 6000 V surge protection Model HM-600N HM-700N HM-800N Input Data (DC) Commonly used module power (W)240 to 405+280 to 470+320 to 540+ Maximum input voltage (V)60 MPPT voltage range (V)16-60 Start-up voltage (V)22 Maximum input current (A)2 × 11.5 2 × 11.5 2 × 12.5 Output Data (AC) Peak output power (VA) 600 700 800 Maximum continuous output power (VA)590 696 766 Maximum continuous output current (A)2.46 2.84 2.90 3.35 3.19 3.68 Nominal output voltage/range (V)1 240/211-264 208/183-228 240/211-264 208/183-228 240/211-264 208/183-228 Nominal frequency/range (Hz)1 60/55-65 Power factor (adjustable)>0.99 default 0.8 leading…0.8 lagging Total harmonic distortion <3% Maximum units per branch2 6 5 5 4 5 4 Efficiency CEC peak efficiency 96.7% CEC weighted efficiency 96.5% Nominal MPPT efficiency 99.8% Nighttime power consumption (mW) <50 Mechanical Data Ambient temperature range (°C)-40 to +65 Dimensions (W × H × D mm)250 × 170 × 28 Weight (kg)3 Enclosure rating Outdoor-NEMA 6 (IP67) Cooling Natural convection – No fans Features Communication 2.4GHz Proprietary RF (Nordic) Monitoring S-Miles Cloud3 Warranty Up to 25 years Compliance UL 1741, IEEE 1547, UL 1741 SA (240 Vac), CA Rule 21 (240 Vac), CSA C22.2 No. 107.1-16, FCC Part 15B, FCC Part 15C PV Rapid Shutdown Conforms with NEC-2017 and NEC-2020 Article 690.12 and CEC-2021 Sec 64-218 Rapid Shutdown of PV Systems Technical Specifications © 2021 Hoymiles Power Electronics Inc. All rights reserved. *1 Nominal voltage/frequency range can vary depending on local requirements. *2 Refer to local requirements for exact number of microinverters per branch. *3 Hoymiles Monitoring System. ELECTRICAL INSPECTION WIRING REPORT APPROVED NOT APPROVED DITCH ROUGH IN/COVER SERVICE FINAL COMMENTS: PV system NOTIFY INSPECTOR at (360) 808-2613 WHEN CORRECTIONS ARE COMPLETED WITHIN 15 DAYS DATE PERMIT # INSPECTOR 10/5/2022 22-925 TAP OWNER CONTRACTOR Solgen Power PROJECT ADDRESS 235 Forest Ave