Loading...
HomeMy WebLinkAbout311 W 3rd Street Address: 3,dStreet PREPARED 9/23/14, 10:23:11 INSPECTION TICKET PAGE 2 CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 9/23/14 ------------------------------------------------------------------------------------------------ ADDRESS . : 311 W 3RD ST SUBDIV: CONTRACTOR POWER TRIP ENERGY CORP PHONE (360) 643-3080 OWNER MATTHEW/C. DUCHOW/R. ANDERSON PHONE 45) 7882 PARCEL 06-30-00-0-0-5165-0000- APPL NUMBER: 14-00000901 RES SOLAR PROJECT ------------------------------------------------------------------------------------------------ PERMIT: BSOL 00 BUILDING PERMIT - SOLAR REQUESTED INSP DESCRIPTION TYP/SQ ' COMPLETED RESULT RESULTS/COMMENTS -------------------------- ------------------------------------------------------------------- BL99 01 9/23/14 L BLDG FINAL &2 September 23, 2014 9:22:51 AM jlierly. V- ' --------------------------- --------- COMMENTS AND NOTES -------------------------------------- CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY& ECONOMIC DEVELOPMENT- BUILDING DIVISION 3 21 EAST 5TH STREET, PORT ANGELES,WA 983 62 Application Number . . . . . 14-00000901 Date 8/08/14 Application pin number . . . 887013 Property Address . . . . . . 311 W 3RD ST ASSESSOR PARCEL NUMBER: 06-30-00-0-0-5165-0000- REPORT SALES TAX Application type description RES SOLAR PROJECT Subdivision Name . . . . . . on your state excise tax form Property Use . . . . . . . . to the City of Port Angeles Property Zoning . . . . . . . RESIDENTIAL HIGH DENSITY Application valuation . . . . 23424 (Location Code 0502) ---------------------------------------------------------------------------- Application desc ROOF MOUNTED GRID-TIED PV SOLAR ARRAY ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ MATTHEW/C. DUCHOW/R. ANDERSON POWER TRIP ENERGY CORP Pb BOX 2984 2343 THOMAS ST SEQUIM WA 98382 PORT TOWNSEND WA 98368 45) 7882 (360) 643-3080 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT - SOLAR Additional desc . . ROOF MOUNTED.SOLAR ARRAY Permit Fee . . . . 403.75 Plan Check Fee 50.00 Issue Date . . . . 8/08/14 Valuation . . . . 23424 Expiration Date 2/04/15 Qty Unit Charge Per Extension BASE FEE 95.75 W 22.00 14.00OQ THOU BL-2001-25K (14 PER K) 308.00 ---------------------------------------------------------------------------- Special Notes and Comments August 7, 2014 4:30:12 PM sroberds. No land use issues anticipated. Engineering on file. Public Works Utility Engineering has no requirements for this plan review. July 30, 2014 1:05:45 PM banders. OK ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 403.75 403.75 .00 .00 Plan Check Total 50.00 50.00 .00 .00 Grand Total 453.75 453.75 .00 .00 Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder) T:Forms/Building Division/Building Permit BUILDING PERMIT INSPECTION RECORD — PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS— Building Inspections 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION: Footings Sternwall Foundation Drainage/Downspouts Piers Post Holes(Pole Bldgs.) PLUMBING: Under Floor/Slab Rough-in Water Line(Meter to Bldg) Gas Line Back Flow/Water FINAL Date Accepted by AIR SEAL: Walls Ceiling FRAMING: Joists/Girders/Under Floor Shear Wall/Hold Downs Walls/Roof/Ceiling Drywall(Interior Braced Panel Only) T-Bar INSULATION: Slab Wall/Floor/Ceiling MECHANICAL: Heat Pump/Furnace/FAU/Ducts Rough-in Gas Line Wood Stove/Pellet/Chimney Commercial Hood/Ducts FINAL Date Accepted by MANUFACTURED HOMES: Footing I Slab Blocking&Hold Downs ,Skirting PLANNING DEPT. Separate Permit#s SEPA: Parking/Lighting ESA: Landscaping ISHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY1 USE Inspection Type Date Accepted By Electrical 417-4735 Construction-R.W. PW I Engineering 417-4831 Fire 417-4653 I Planning 417-4750 Building 417-4815 T:Forms/Building Division/Building Permit .......... CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY&ECONOMIC DEVELOPMENT-BUILDING DIVISION 321 EAST 5TH STREET, PORT ANGELES,WA 98362 Application Number . . . . . 14-00000901 Date 8/08/14 Application pin number . � . 88'1013 Property Address . . . . 311 W 3RD ST ASSESSOR PARCEL NUMBER: 06- 3D 00.0 0-51G5-0000- REPORT SALES TAX Application type description RES SOL_A_R PROJ_ECT Subdivision Name . . . . . . on your state excise tax form Property Use . . . . . . . . to the City of Port Angeles PrOperLy Zoning . . , � . . . RESIDENTIAL, HIGH DENSITY Application valuation . . . . 23424 (Location Code 0502) ------------------------------------------------------------------------------ Application desc ROOF MOUNTED GRID-TIED PV SOLAR ARRAY ----------------------------------1-------------------------------------------- Owner Contractor ------------------------ ------------------------- MATTHEW/C. DUCHOW/R, ANDERSON POWER TRIP ENERGY CORP P6 BOX 2984 12-343 q44 53 MO. SEQTJIM WA 98382 PORT TOWNSEND WA 98368 45) 7882 (360) 643-3080 51 ---------------------------------------------------------------------------- Permit . I . . . . BUILDINd. PERMIT - SOLAR Additional desc ROOF MOUNTED.SOLAR ARRAY Permit Fee 403.75 Plan Check Fee 50.00 Issue Date . . . . 8/08/14: valuation 23424 Expiration Date . . 2/04/15 Qty Unit Charge Per Extension BASE FEE 95.75 22.00 14.006Q TT40U BL-2001-25K (14 PER X) 308.00 ---------------I—- -------------------------------------------------------- Special Notes and Comments August 7, 2034 4!3C:12 PM sroberds. No land use issues anticipated. Engineering on file. Public Works Utility Engineering has no requirements for this plan review. July 30, 2014 ,1.05:45 PM banders. OK ----------------------------------------------------------------- -------7- Fee summary Charged Paid Credited Due ----------------- ---------- ----- ---- ---------- -------- Permit Fee Total. 403.75 403.-/S .00 .00 Plan Check Total 50.00 50.00 .00 .00 Grand Total 453.75 453.75 .00 .00 Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced,or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true a'nd Correct. All provisions of laws and ordinances governing this type of work.will be complied with whether specified herein or not, The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. J�k Lyg Cate Print Name Sign�tAure of Contractor o0A thorized Agent Signature'of Owner(if owner is builder) r.Formsfflullding Division[Buildifig Permit THE For City U CITY OF Permit# W A S H I N G T 0 N. U. S Date Received: /7/5--f # 321 E Sth Street Date Approved /X / / 11� Port Angeles,WA 9836 //0-A P:360-417-4817 F:360-417-4711 Email:perm!ts@cJtyofpaus BUILDING PERMIT APPLICATION ProjectAddress: Aru c,-� W A- 8 Phone: :!5(&-,0'Of 31, 0 0 Primary Contact: Email: Tc-H�4 4& R-W T'R4 i�14 1�:P-4'Y,C-014� Name Phone kR AA OMSIA� 3,4;:�,0 -708 153 Property MailingAddress Email 'p JLD 5;r AA, *-Krb-c:CM 7 C'- Owner city State Pe P-T Av eNcl'cs- Nape Phone Address Email Contractor TCKN & PC,.,J J��-rJZJ CC^ QVB, Information city State WA Zip erj.3�6 e Contractors license# T�?(-IlAaEkM- 13,4tQE Ev.Date: it/-5 7-2-0 15 Legal Description: Zoning: Tax Parcel# e,6-3o'- Proj ect Value: (materials and labor) -f A R,�kP �M)-tC'510iCCVC) s Z �>,;q2q, Zi Residential 0 Commercial El Industrial 11 Public Permit Demolition 0 Fire 11 Repair 11 Reroof(tear off/lay over)( Classification For the following,fill out both 11ag-es of permit application: (check New Construction 11 Exterior Remodel 11 Addition 1:1 Tenant Improvement appropriate) I Mechanical 0 Plumbing El Other 11 Fire Sprinkler System? Irrigation Syste oposed Bathrooms roposed Bedrooms Yes 0 No )9 Yes 13 No Ef Project Description Is project in a Flood Zone: Yes NoC4 Flood Zone Type: If in a Flood Zone,what is the value of the structure before proposed improvement? $ I have read and completed the application and know it to be true and correct. I am authorized to apply for this permit and understand that it is my responsibility to determine what permits are required and to obtain permits prior towork. I understand that plan review fees are not refundable after review has occurred. I understand that I will forfeit review fees if I withdraw the application before the permit is issued. I understand that if the permit is not picked up/issued withint8o days of submittal,the application will be considered abandoned and the fees will be forfeited. Date Print Name Signature I cc_�))I rip WAK Z3W(Jc) 2�, I(�o g)Fit n eA M z%- ,�007 00,-, Z� Proposed 24 solar modules on house's southwest roof -nate Property Approxit 3rd Street NORTH Base nial) from Google Maps X SnapNrack Series 100 Snap rack- Project Info: Dealer: Trip Energy Cc Project Namie:1 Duchow Create Dated 2014-07-29Tl5:50:25-0760-1 PV Module Data: Module Brand itek Energy Length 64.80 inches Model iT-270 Width 39.1 inches Depth 2.00 inches Environmental Requirements: Weight 43.00 pounds Topographic Condition Coast:a:l== Rated power @ STC 27000 W Standard IBC 2012 Rail Color Snow Load 21-30 psf Item 8 checklist Racking Color Item 7 checklist Wind Speed 130 mph eff R fter Spacing 24 inches douglas fir 2A spans 3',5.5'&6.5' Roof Attachment Flashed L-Foot System Style: Rail Finish Clear Anodized End Clamp Type Universal Grounding Method UL 2703 Listed Micro Attachment Kits No Edge Screen Trim? No if 11 Yes",4" or 8"screen? Screen Height inches Tilt Up? No Sub-Arrays: UL2703 Yes Premium Allay Rail No Bulk customer No Sub-Array Sub-Array 122" Rail 162" Rail Rail Mid End Edge Roof Modules Splices Clamps Clamps Screen Attachments 1 12 0 6 0 18 12 0 18 F_ 18 TOTALS 12 0 0 12 0 18 CITY OF PORT ANGELES—Construcl ion r1wift The Issuance of this permh tipon these plans,spn�_ifi- cations and other dati q�,4 not p;�­it the building official from thereafter repv�,;ig the corre,`na of errors in said plans, specification! and other data, tw 11mm preventing building operations king carried on t�,ereunder when in violation of all codes md o,- w,-�ces of this jurisdiction. 2 Approval Da, By LL �A ef SnapNrack Series 100 Calculator Proposed Bill of Materials Part Number Description Qty 015-09824 SNAPNRACK,STANDARD RAIL SET, 1621N,CLEAR,6 PC 1 242-02052 SNAPNRACK, BONDING MID CLAMP ASSEMBLY, 1.50-2.00IN,CLEAR 18 242-02063 SNAPNRACK, BONDING UNIVERSAL END CLAMP ASSEMBLY 12 232-01023 SNAPNRACI(RAIL END CAP,S TANDARD, BLACK 12 242-02700 SNAPNRACK, BONDING L-FOOT KIT W/BASE AND FLASHING,CLEAR L-FOOT 18 Item 13 checklist 242-02101 SNAPNRACK, GROUNDING LUG ASSEMBLY 3 Total SnapNrack Weight: 73.53 lbs System Total Weight: 620.00 lbs jArray Area=12 modules X(39.1"x 64.8"/144 sq.inch per sf)=211 sf I Pounds per Square Foot of Array 620 lbs/211 sf=2.94 psf �Item 9�checkli i�st Pounds per Attachment=620 lbs 24=26 lbs per Attachment Item 11 checklist U-C nj 'Duchow(v.0.6.16) 2014-07-29T14:27:31-0700 Sub-Array#1 P(3x5) Group 1 Group 2 Group 3 Group 4 Group 5 122" 162" Row Mid Row End Row Attach- Module Rail Rail Rail Rail Rail Rail Rail Rail Clamps Clamps Splices ments Bonding Bonding Length Length Length Length Length Qty Qty 157.4 - 0 2 6 4 0 8 0 1 157.4 - 0 2 6 4 0 8 0 1 157.4 - 0 2 6 4 0 8 0 1 Sub-Array Totals: 0 6 18 12 0 24 0 3 n[]MM 4-- Tat Orientation Rows Columns I It Portrait 3 5 FINNI[Ir Oloop Array Pitch Building Attachment Attachment Spacing Height Spacing Override ���w EK4 32 degrees 1 18 feet 72inches 48inches A4,W( LAYC-� CKCWPacF Sub-Array Modules Edge Screen Array Po��e� W6-sT RAAf Of 12 0 ft 3 kW wc HOW SnapNrack PV Mounting System- +(877)732-2860-775 Fiero LN,Suite 200.San Luis Obispo,CA 93401 2 of 2 �s itek Energy HE Solar Module The high performance, high quality anc� affordable solar solution • Made-in-Washington using Cutting Edge High Efficiency Mono Crystalline Cells • 25-Year Power Output Warranty • I 0-Year Workmanship Warranty • Exceptional Power Density (watts/rr�) MECHANICALDATA. 0 0 GENERAL DATA Ceilf,p­ 60 Super High Efficiency Mono crystalline cells 39.1 X 64.8"X 2" -6 X 10 cell matrix .3 by-pass diodes Glass Ultia clear,low iron tempered solar glass with anti-glare prisr-notic subsurface texture Backsheet Multi layered,highly resistant polyester MAXIMUM RATINGS Frame High strength anodized aluminum frame Operational Temperature -40...+90'C compatible with both top-down clamps and Maximum System Voltage 600V bottom flange mounting -Numerous flange Design I oad(UL 1703) up to 113 lbs/ft mounting holes on inch dimension centers -Mounting holes specifically for Maximum Load(UL 1703) 55,1=kg/ry� 5400 Pa) micro-inverter applications Cable 42"90C 11.AWG PV wire Max Series fuse Rating 15A Connector N1 C 4 Max Reverse current 15A Grounding Certified for Wiley Electronics WEEBT1 NOTE: Specifications subject grounding clips -Eight standard grounding to change without notice locations per module for reduced ground wire length 1647mm(64.8") TEMPERATURE RATINGS Nominal Opecaling 48.20 IC Cell Temperature(NOCT) Temperature Coefficient of P- -0,47%rc 3 Tempeiatuie Coefficient of V, -0.32%/*C Temperature Coefficient of I +0.04 T./1C Temperature Coefficient of V 0.45%J-C 50mm(2"thick) Backside of5olar Module QUALIFICATIONS UL Listing UL 1703 IT IT IT IT ELECTRICAL DATA* 2551[HE 2610T HE 265 HE 270 FIE 275 HE 280 HE' fire Rating Class C Maximum Power-t,.(Wp) 255 260 265 270 275 280 Made in Washington State maximum Power voltage-V_(V) 31.5 31.7 31.8 32.0 32.1 32.3 Maximum Power Current-1-,(A) 8.1 8.2 8.3 8.4 8.5 8.6 Open Circulf Voltage-N�,(V) 38.4 38.6 38.7 38.9 39.0 39.2 *�Wgl P Short Circuit Current-1,c(A) 8.8 8.9 9.0 9.1 9.2 9.3 0 0 Power Density(Wlrn') 155.8 158.8 161.9 164.9 168.0 171.0 kenergy 7-60.647.953' 1 itekenergy.corn VO4.031 1 Friday,January 31,2014 N SnapNrack S,,nap"I"' ., rack- Norman 775 Fiero Lane,Suite 200 San Luis Obispo,CA 93401 Ncheel "Series 100 Roof Mount"Cover Letter To Whom It May Concem, 0�4W We have performed calculations for the 100 series roof mount PV system based on Ntructural the information provided by SnapNrack. Included with this letter are the report and calculations. We did the calculations in accordance with the 2012 IBC,ASCE 7-10, 2012 NDS, and guidelines slated in the Solar America Board for Codes and En g i n e e r Standards. Some of the components in the SnapNrack test data were used to determine the 5022 Sunrise Blvd. capacity and section properties of materials. We collected the test data using the Fair Oaks,CA 95628 procedures outlined in the 2012 IBC Chapter 17. (916)536-9585 (916)536-0260(fax) We included the following types of load combinations and building parameters into our calculations: 1989-2013 24 yeanv of excellence 0 ASCE 7-10 wind speeds from 110 mph to 190 for B and C exposure categories ASCE 7-10 Seismic Design Category E ASCE 7-10 Snow Loads up to 120 psf ground snow Buildings with mean roof heights up to 60foot tilt angles / roof pitches Norman Scheel,S.E. from 0 degrees to 60 degrees. I ZED AP BD+C IXED AP Homes The calculations have also been completed in accordance with the 2006 IBC,2009 Fellow—SEAOC IBC, and ASCE 7-05. To use the data contained in this packet for projects that are Fellow-ASCE E-ma il;n.(Li m( �P_nssecqn) being evaluated to the older ASCE 7-05 wind speeds,refer to Appendix A for a Rob Coon wind speed conversion chart. Find the ASCE 7-05 (IBC 2006/2009)wind speed in General Manager the Chart in Appendix A,identify the corresponding.ASCE 7-10 (IBC 2012)wind E-mail:191)�0011 a2m_­�mn speed value,and proceed with using the charts contained in this packet with the Steve Smith P.E. adjusted wind speed value. Project Manager E-mail: In our opinion, the mounting system, outlined by SnapNrack Senes 100 PV Mounting System Code Compliance Installation. Manual, is acceptable and meets Steven Cooksey the loading requirements as stated above. See the report and calculations included CAD Supervisor E-mail:stevcO�i)sse.co. with this letter for more information. If there are any further questions,please contact Norm Scheel. J. Sc Jaclde Winslow Office Manager E-mail:iackie nssc..�9�1.n Nonnan Scheel PE, SE LEED-AP BD+C,LEED-AP Homes Fellow S)ijiOC Fellow,W.C.E. NO, S EXPIRES DECEMBER 26. Z�&Fll OVER-THE-COUNTER BUILDING PERMIT CHECKLIST FOR RESIDENTIAL SOLAR r% PHOTOVOLTAIC SYSTEMS: ROOFTOP MOUNTED Contractors can apply for an over-The-Counter(OTC)permit where the PV system meets the requirements listed in this Checklist All project plans and supporting documentation must be provided on sitefor the inspector. --------TO BE COMPLETED BY APPLICANT------- 1) Project Information Property owner Name: Matthew W. &Cheryl Duchow and Ruth V.Anderson vo ii Project Address: 3 rl Street Parcel# 0630000051650000 ZIP:9836 city: Port Angeles State:WA 2 Day P email: 360-808-4153;duchowmc@yahoo.com Contractor lame, Power Trip Energy Co.,John Fleming -Primary Contact: - Contractor License#: General:POWERTE934QE exp. 11/5/15, Electrical: POWERTE964JN exp.4/15/16 __Contractor Phone& 360-643-3080;john@powertripenergy.com -email: PV system description Roof mounted,Grid-tied PV system-6.48 kW nominal total module syste�;size,24� (include manufacturer @ 270 watt Itek Energy PV modules,2 @ 3.8 kW Eltek inverters,7.6 kW total and model#of major inverter size. FOXet-T VAL,4e'. equipment): 2) Determine if your project qualifies for expedited permitting: Yes No 1. PV system is designed and proposed for a detached one or two family dwelling or X 0 townhouse not more than three stories above grade or detached accessory structure that is code compliant to setbacks and height,or code allows expansion of nonconformity for solar modules. [IRC 101.21 2. Modules on pitched roofs do not exceed the highest point of the roof unless approved by X [I the local jurisdiction. 3. Rooftop is made from lightweight material such as a single layer of composition shingles, X 0 metal roofing, lightweight masonry,or cedar shingles. 4. The installation shall comply with the manufacturer's instructions. [IRC M2302.2]_ X 11 5. The installation shall meet the requirements of NFPA 70 National Electrical Code,and all X 0 required electrical permit(s) must be obtained from the Authority Having Jurisdiction to administer the electrical code. [IRC M2302.2] 6. The installation shall meet the requirements of the International Fire Code as amended X E3 by WA State. [I RC M2302.2] 7. The PV system is designed for the wind speed of the local area,and will be installed per X 0 the manufacturer's specifications. [IRC M2302.2.1(1)] 8. The ground snow load does not exceed 70 pounds per square foot. [IRC M2302.2.1(2)] X El 9. Total dead load of modules,supports, mountings,raceways and all other appurtenances X weigh no more than four pounds per square foot. [IRC M2302.2.1(3)] Enter total dead load of system (lbs/ft2):3 10. To address uplift,modules are mounted no higher than 18" above the surfac of the X 0 roofing to which they are affixed. [IRC M2302.2.1(4)] 11. Supports for solar modules are installed to spread the dead load across as many roof- X 0 framing members as needed to ensure that no point load exceeds fifty(50) pounds. [IRC M2302.2.1(5)] 12. The photovoltaic modules and supporting structure shall be constructed of X noncombustible materials or fire-retardant treated wood equivalent to that required for the roof construction. [IRC M2302.2.1] 13. Roof and wall penetrations shall be flashed and sealed to prevent entry of water, X 0 rodents,and insects. [IRC M2302.2.2] 14. PV modules are listed and labeled with a fire classification in accordance with UL 1703. X 0 [IRC M2302.2.3] 11 Comments: Net metering agreement approved by Terry Dahlquist on 7/18/2014. Electrical permit approval is pending. => if you answered yes to all of the above questions,the project qualifies for the over-the- counter permitting process. 3) Submit this Checklist, Site Plan, and other required permit application forms to: The City of Port Angeles 321 E S'Street Port Angeles, WA 98362 P.360-417-4817f. 360-417-4711 Email:permits@city0fPa-us => As the property owner or authorized representative of the above listed property, I attest that all information in this checklist is accurate to the best of my knowledge. Applicant Signature: Date:7/21/2014 Applicant Name(Please Print): PowerTripEn o,John Fleming --------TO BE COMPLETED BY CITY STAFF------ Qualifies for OTC Building Permit? OYes 514o Permit Application#: Staff Initials Date: 2