PREPARED 7/03/14, 14:12:25 INSPECTION TICKET PAGE 1
CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 7/03/14
----------------------- ---------- ----- ------ ---- -------
ADDRESS . : 3112 GRANTS VIEW LN SUBDIV:
CONTRACTOR : PHONE
OWNER MONICA D QUEVEDO AND RAY J VEI PHONE
PARCEL 06-30-15-5-1-2831-0000-
APPL NUMBER: 13-00001446 RES NEW SFR
------------------------------------------------------------------------------------------------
PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
BL1 01 2/07/14 PB BLDG FOUNDATION FOOTING
2/10/14 DA February 7, 2014 11:39:33 AM pbarthol.
Tommy 477-0078
Ray 949-350-5438
February 10, 2014 8:44:17 AM pbarthol.
need engineers letter on retaining wall and footing setback
from retaining wall.
BLFW 01 2/10/14 PB BLDG FOUND FTG/STEM WALL
2/10/14 AP February 11, 2014 11:43:00 AM pbarthol.
February 11, 2014 11:44:35 AM pbarthol.
ufr ground ok. received letter from engineer on retaining
wall/footing placement.
BLFD 01 2/20/14 JLL BLDG FOUNDATION DRAINAGE
2/20/14 AP February 20, 2014 9:41:48 AM pbarthol.
Ray 949-350-5438
February 20, 2014 3:22:46 PM jlierly.
BFF 01 3/03/14 JLL BLDG FLOOR FRAMING
3/03/14 AP March 3, 2014 10:40:35 AM pbarthol.
Ray 949-350-5438
March 3, 2014 4:18:19 PM jlierly.
BL9 01 3/26/14 JLL BLDG SHEARWALL
3/26/14 DA March 26, 2014 12:07:30 PM pbarthol.
RAY 949-350-5438
March 26, 2014 3:54:25 PM jlierly.
Renail shear panels to engineer specs on plans/ recall when
ready/jll
BL9 02 3/28/14 JLL BLDG SHEARWALL
3/28/14 AP March 28, 2014 9:45:44 AM pbarthol.
Ray 949-350-5438
March 28, 2014 3:56:32 PM jlierly.
BAIR 01 4/14/14 JLL BLDG AIR SEAL
4/14/14 AP April 14, 2014 11:56:46 AM pbarthol.
RAY 949-350-5438
April 14, 2014 4:21:53 PM jlierly.
BL3 01 4/14/14 JLL BLDG FRAMING
4/14/14 AP April 14, 2014 11:56:23 Am pbarthol.
RAY 949-350-5438
April 14, 2014 4:21:53 PM jlierly.
BLI 01 4/15/14 JLL BLDG INSULATION
4/15/14 AP April 15, 2014 9:02:29 AM jlierly.
April 15, 2014 4:15:56 PM jlierly.
PW99 01 6/25/14 RV PUBLIC WORKS FINAL
6/25/14 AP June 25, 2014 10:18:48 AM rvess.
June 25, 2014 10:19:05 AM rvess.
BL99 01 7/03/14 JLL BLDG FINAL
July 3, 2014 12:44:08 PM pbarthol.
----------------------------------- CONTINUED ONTO NEXT PAGE -----------------------------------
PREPARED 7/03/14, 14:12:2S INSPECTION TICKET PAGE 2
CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 7/03/14
------------------------------------------------------------------------------------------------
ADDRESS . : 3112 GRANTS VIEW LN SUBDIV:
CONTRACTOR : PHONE
OWNER MONICA D QUEVEDO AND RAY J VEI PHONE
PARCEL 06-30-15-S-1-2831-0000-
APPL NUMBER: 13-00001446 RES NEW SFR
------------------------------------------------------------------------------------------------
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
Ray 949-350-5438
------------------------------------------------------------------------------------------------
PERMIT. ME 00 MECHANICAL PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
ME1 01 4/09/14 JLL MECHANICAL ROUGH-IN
4/14/14 AP April 9, 2014 9:00:06 AM pbarthol.
Ray 949-3SO-5834
April 14, 2014 12:00:01 PM jlierly.
ME99 01 7/03/14 JLL MECHANICAL FINAL
July 3, 2014 12:45:05 PM pbarthol.
Ray 949-350-S438
------------------------------------------------------------------------------------------------
PERMIT: PL 00 PLUMBING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
PL2 01 4/03/14 JLL PLUMBING ROUGH-IN
4/03/14 AP April 3, 2014 9:40:23 AM pbarthol.
Ray 949-3SO-5438
April 3, 2014 4:26:42 PM jlierly.
PL99 01 7/03/14 JLL PLUMBING FINAL
July 3, 2014 12:45:12 PM pbarthol.
Ray 949-3SO-5438
-------------------------------------- COMMENTS AND NOTES --------------------------------------
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT- BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES, WA 98362
Application Number . . . . . 13-00001446 Date 1/17/14
Application pin number . . . 998444
Property Address . . . . . . 3112 GRANTS VIEW LN
ASSESSOR PARCEL NUMBER: �06-30-15-5-1-2831-0000- QS
Application type description RES NEW SFR REPORT SALES TAX
Subdivision Name . . . . . . on your state excise tax form
Property Use . .. . . . . . .
Property Zoning . . . . . . . RS7 RESDNTL SINGLE FAMILY to the City of Port Angeles
Application valuation . . . . 150500 (Location Code 0502)
----------------------------------------------------------------------------
Application desc
New SFR in RS-9 Zone
---------------------------------------------------------------------------- <
Owner Contractor
------------------------ ------------------------
MONICA D QUEVEDO AND RAY J VEI OWNER
1541 Taylor Cutoff Rd.
Secfuim
SEQUIM WA 98382
----------------------------------------------------------------------------
Permit . . . . . . BUILDIN G PERMIT -RESIDENTIAL
Additional desc 1G40 SQ FT SFR
Permit Fee . . . . 1305.85 Plan Check Fee 848.80
Issue Date . . . . 1/17/14 Valuation . . . . 150500
Expiration Date . . 7/16/14
Qty Unit Charge Per Extension
BASE FEE 1020.25
51.00 5.6000 THOU BL-100,001-500K (5.60 PER K) 285.60
----------------------------------------------------------------------------
Permit . . . . . MECHANICAL PERMIT
Additional desc . SFR MECHANICAL Pr
Permit Fee . . . . 104,45 Plan Check Fee .00
Issue Date . . . . 1/17/14 Valuation . . . . 0
Expiration Date . . 7/16/14
Qty Unit Charge Per Extension
BASE FEE 50.00
1.00 14.8000 EA ME-FURN/HP/FAU < OR = 5 TON 14.80
4.00 7.2500 EA ME-VENT FAN (SINGLE DUCT) 29.00
1.00 10.6500 EA ME-HOOD/DUCT-MECH. EXHAUST 10.65
----------------------------------------------------------------------------
Permit . . . . PLUMBING PERMIT
Additional desc SFR PLUMBING
Permit Fee . . . . 212,00 Plan Check Fee .00
Issue Date . . . . 1/17/14 Valuation . . . . 0
Expiration Date . . 7/16/14
Qty Unit Charge Per Extension
BASE FEE 50.00 41
11.00 7.0000 EA PL-PLUMBING TRAP 77.00
1.00 7.0000 EA PL-WATER LINE 7.00
8.00 7.0000 EA PL-DRAIN VENT PIPING 56.00
Separate Permits are required forelectrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
J,
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
BUILDING PERMIT INSPECTION RECORD
PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS–
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL,TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage/Downspouts
'Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-in
Water Line(Meter to Bldg)
Gas Line
Back-Flow/Water FINAL Date Accepted by
AIR SEAL:
Walls
Ceiling
FRAMING:
'jo—ists-TG—irders Under Floor
Shear Wall I Hold Downs
Walls/Roof/Ceiling
Drywall(Interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pump/Furnace/FAU/Ducts
Rough-In
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts FINAL Date Accepted by
MANUFACTURED HOMES:
Footing/Slab
Blocking&Hold Downs
Skirting
PLANNING DEPT. Separate Permit#s SEPA:
Parking/Lighting ESA:
Landscaping ISHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY1 USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction-R.W. PW I Engineering 417-4831
Fire 417-4653
Planning 417-4750
Building 417-4815
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY& ECONOMIC DEVELOPMENT- BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES, WA 98362
Page 2
Application Number . . . . . 13-00001446 Date 1/17/14
Application pin number . . . 998444
Qty Unit Charge Per Extension REPORT SALES TAX
1.00 15.0000 EA PL-SEWER LINE 15.00 on your state excise tax form
1.00 7.0000 EA PL-WATER HEATER 7.00
---------------------------------------------------------------------------- to the City of Port Angeles
Special Notes and Comments
December 30, 2013 11:31:34 AM tamiot. (Location Code 0502)
ELECTRICAL PERMIT WILL BE REQUIRED. UNDERGROUND SERVICE FROM
EXISTING PED AT SE CORNER.
Address numbers shall be plainly visible from the street.
Address numbers shall be a minimum of six inches high and be
of contrasting color from the background.
December 30, 2013 9:37:43 AM sroberds.
The proposal will result in a new sfr in the RS-7 for total
Jot cov of 21% and site cov of 35%. The site plan indicates
25' front and rear setbacks; the RS-7 zone allows for 201
setbacks. No land use issues anticipated.
Consider applying for the City Green Infrastructure Rebate
of up to $750.00 towards the materials to install rain
garden to control roof and driveway runoff. Also rebates
available for downspout disconnections.Contact Jonathan
Boehme at 360 417-4811
Trench safety per applicable laws. Temp erosion control and
surface restoration responsibility of applicant. Contact
City inspector prior to start of work @ 360 417-4831. No
attachment to sanitary sewer of stormwater roof leaders,
foundation drains, yard drains, or any other CSO
contribution is allowed.
Sanitary sewer connection inspection is required by
Public Works prior to back fill of ditch. 24 hour advance
notice is required. Public Works Inspection request line
417-4831
Construct driveway to City Standards. Concrete with exposed
aggregate or other non-standard finishes(including colors or
dyes)are not allowed in the City road right of way. Broom
finish only. An inspection by Public Works Engineering is
required prior to pouring concrete. Public Works inspection
request line 417-4831
----------------------------------------------------------------------------
Other Fees . . . . . . . . . RES UNDERGRND SERVICE FEE 770.00
SEWER SYSTEM DELV CHARGE 2260.00
STATE SURCHARGE 4.50
PW WATER SYSTEM USE FEE 2260.00
---------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
---------------- ---------- ---------- ---------- ----------
Permit Fee Total 1622.30 1622.30 .00 .00
Plan Check Total 848.80 848.80 .00 .00
Other Fee Total 5294.50 5294.50 .00 .00
Grand Total 7765.60 7765.60 .00 .00
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
BUILDING PERMIT INSPECTION RECORD
PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS—
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL,TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Sternwall
Foundation Drainage/Downspouts
'Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor I Slab
Rough-In
Water Line(Meter to Bldg)
Gas Line
Back Flow/Water FINAL Date Accepted by
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall(interior Braced Panel Only
T-Bar
INSULATION:
Slab
Wall I Floor/Ceiling
MECHANICAL:
Heat Pump/Furnace I FAU/Ducts
Rough-in
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts FINAL Date Accepted by
MANUFACTURED HOMES:
Footing/Slab
Blocking&Hold Downs
Skirting
PLANNING DEPT. Separate Permit#s A:
Parking/Lightin ESA:
Landscaping ISHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY1 USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction- R.W. PW I Engineering 417-4831
Fire 417-4653
Planning 417-4750
Building 417-4815
I R r
4
0* CITY OF PORT ANGELES
PUBLIC WORKS & UTILITIES
321 EAST 5TH STREET, PORT ANGELES, WA 98362
Application Number . . . . . 13-00001446 Date 1/17/14
Application pin number . . . 998444
Property Address. . . . . .. . 3112 GRANTS VIEW LN REPORT SALES TAX
ASSESSOR PARCEL NUMBER: OG-30-15-5-1-2831-0000- on your state excise tax form
Application type description RES NEW SFR
Subdivision Name . . . . . . to the City of Port Angeles
Property Use . . . . . . . . (Location Code 0502)
Property Zoning . . . . . . . RS7 RESDNTL SINGLE FAMILY
Application valuation . . . . 150500
----------------------------------------------------------------------------
Application desc
New SFR in RS-9 Zone
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
MONICA D QUEVEDO AND RAY J VEI OWNER ,
1541 Taylor Cutoff Rd.
Sequim
SEQUIM WA 98382
------------------------------------------------------ ---------------------
Permit . . . . . . DRIVEWAY INSTALLATION
Additional desc . .
Permit Fee . . . . 180.00 Plan Check Fee .00
Issue Date . . . . 1/17/14 Valuation . . . . 0
Expiration Date 7/16/14
Qty Unit Charge Per Extension
BASE FEE 180.00
----------------------------------------------------------------------------
Permit . . . . . . PUBLIC WORKS RES WATER SERV
Additional desc . . 5/811 DROP IN WATER METER
Permit Fee . . . . 420.00 Plan Check Fee .00
Issue Date . . . . 1/17/14 Valuation . . . . 135000
Expiration Date . . 7/1G/14
Qty Unit Charge Per Extension
1.00 420.0000 EA PW WATER METER DROP IN 420.00
------------------------------------------- --------------------------------
Permit . . . . . . SANITARY SEWER HOOK UP
Additional desc
Permit Fee . . . . 150-00 Plan Check Fee .00
Issue Date 1/17/14 Valuation . . . . 135000
Expiration Date 7/16/14
Qty Unit Charge Per Extension
1.00 150.0000 EA SAN SEWER HOOKUP 150.00
----------------------------------------------------------------------------
Special Notes and Comments
December 30, 2013 11:31:34 AM tamiot.
ELECTRICAL PERMIT WILL BE REQUIRED. UNDERGROUND SERVICE FROM
EXISTING PED AT SE CORNER.
Address numbers shall be plainly visible from the street.
Address numbers shall be a minimum of six inches high and be
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permitbecomes
null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned
for a period of 180 days after the work as commenced,or if required inspections have not been requested within 180 days from the last
inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of
laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Signature of Contractor or Authorized Agent Date Signature of Owner(if owner is builder) Date
T:\Po1icies\1 102.15[10/08]
PERMIT INSPECTION RECORD
CALL 417-4831 FOR UTILITY INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. ITIS UNLAWFUL TO COVER,
INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INA CONSPICUOUS LOCATION.
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE
INSPECTION TYPE DATE ACC PTED COMMENTS
YES NO
PW UTILITIES (Engineering Division)
WATERLINE I METER
SEWER CONNECTION
SANITARY
STORM
SITE DRAINAGE
SITE EROSION CONTROL
PARKING
SIDEWALK
CURB&GUTTER
DRIVEWAY APPROACH
BACK-FLOW DEVICE
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCYfUSE
RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED
YES NO
CONSTRUCTION R.W./PW/ CONSTRUCTION-R.W.
ENGINEERING 417-4831 PW/ENGINEERING
FIRE 417-4653 FIRE DEPT.
PLANNING DEPT. 417-4750 PLANNING DEPT.
BUILDING 417-4815 BUILDING
T:\Policies\l 102.15[10/08]
CITY OF PORT ANGELES
PUBLIC WORKS & UTILITIES
321 EAST 5TH STREET, PORT ANGELES, WA 98362
Page 2
Application Number . . . . . 13-00001446 Date 1/17/14
Application pin number . . . 998444 REPORT SALES TAX
---------------------------------------------------------------------------- on your state excise tax form
Special Notes and Comments
of contrasting color from the background. to the City of Port Angeles
December 30, 2013 9:37:43 AM sroberds. (Location Code 0502)
The proposal will result in a new sfr in the RS-7 for total
lot cov of 21% and site cov of 35%. The site plan indicates
25' front and rear setbacks; the RS-7 zone allows for 20'
setbacks. No land use issues anticipated.
Consider applying for the City Green Infrastructure Rebate
Of Up to $750.00 towards the materials to install rain
garden to control roof and driveway runoff. Also rebates
available for downspout disconnections.Contact Jonathan
Boehme at 3GO 417-4811
Trench safety per applicable laws. Temp erosion control and
surface restoration responsibility of applicant. Contact
City inspector prior to start of work @ 360 417-4831. No
attachment to sanitary sewer of stormwater roof leaders,
foundation drains, yard drains, or any other CSO
contribution is allowed.
Sanitary sewer connection inspection is required by
Public Works prior to back fill of ditch. 24 hour advance
notice is required. Public Works Inspection request line
417-4831
Construct driveway to City Standards. Concrete with exposed
aggregate or other non-standard finishes(including colors or
dyes)are not allowed in the City road right of way. Broom
finish only. An inspection by Public Works Engineering is
required prior to pouring concrete. Public Works inspection.
request line 417-4831
----------------------------------------------------------------------------
Other Fees . . . . . . . . . RES UNDERGRND SERVICE FEE 770.00
SEWER SYSTEM DELV CHARGE 2260.00
STATE SURCHARGE 4.50
PW WATER SYSTEM USE FEE 2260.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 750.00 750.00 .00 .00
Plan Check Total .00 .00 .00 .00
Other Fee Total 5294.50 5294.50 .00 .00
Grand Total 6044.50 6044.50 .00 .00
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned
for a period of 180 days after the work as.commenced,or if required inspections have not been requested within 180 days from the last
inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of
laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Signature of Contractor or Authorized Agent Date Signature of Owner(if owner is builder) Date
T-\Po1icies\1 102.15[10/081
PERMIT INSPECTION RECORD
CALL 417-4831 FOR UTILITY INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. ITIS UNLAWFUL TO COVER,
INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INA CONSPICUOUS LOCATION.
KEEP PERMIT CARD AND APPROVED PLANS ATJOB SITE
INSPECTIONTYPE DATE ACCEPTED CONINIENTS
YES NO
PW UTILITIES (Engineering Division)
WATERLINE/METER
SEWER CONNECTION
SANITARY
STORM
SITE DRAINAGE
SITE EROSION CONTROL
PAR-KING
SIDEWALK
CURB&GUTTER
DRIVEWAY APPROACH
BACK-FLOW DEVICE
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED
YES NO
CONSTRUCTION R.W./PW/ CONSTRUCTION-R.W.
ENGINEERING 417-4831 PW/ENGINEERING
FIRE 417-4653 FIRE DEPT.
PLANNING DEPT. 417-4750 PLANNING DEPT.
BUILDING 417-4815 BUILDING
TAPolicies\I 102.15[10/08]
THE 0D.1"r For City Use
CITY OF X GELES.
Permit#
P -A�L Perr
W A SH INGTON , U . S .
ate Received:
321 E 5th Street jDate Approved
Port Angeles,WA 9836
P:360-417-4817 F: 360-417-4711
Email:permits0cityofpa.us LI
BUILDING PERMITIAICATION
7
_A(7\ �� 1
Project Address: "Eui --
Primary Contact: Phone: 319
Email:
RM R L")W juln
5@Woo '
Narn7-%
)2f�
Phone
OM -'--�
Property I Add Ernailp CA
Owner
State zip
cit�—EQwry\
WR
Name Phone
— 9�' w� �� -*�%-
Contractor Addr yk--3+�ANia Email
Information city�SlEm'Nw-\ State MA zip CIS30a
Lc:ontractor 1,icense# P, Exp.Date:
z ]a-
Legal Description: Zoning: Tax Parcel # Pr9j ect Value: (materials and labor)
T oc;�Ols 5 ias'-31 $ -06TG007, clo /1A'5-'00
Residential 4K Commercial El Industrial 1:1 Public El
Permit Demolition El Fire 11 Repair 1:1 Reroof(tear off/lay over) 0
Classification For the following, fill out both pages of permit application:
(check New Construction�K Exterior Remodel El Addition 11 Tenant improvement
appropriate) I Mechanical El Plumbing 11 Other 11
Willa fire sprinkler system be installed Irrigation System? Proposed Bathrooms � Proposed Bedrooms
or modified? Yes 0 No Yes 0 NoIK I/
3
Project Description
Is project in a Flood Zone: Yes 0 NoO Flood Zone Type:
If in a Flood Zone, what is the value of the structure before proposed improvement? $
1 have read and completed the application and know it to be true and correct. I am authorized to apply for
this permit and understand that it is my responsibility to determine what permits are required and to
obtain permits prior to work. I understand that plan review fees are not refundable after review has
occurred. I understand that I will forfeit review fees if I withdraw the application before the permit is
issued. I understand that if the permit is not picked up/issued within 18o days of submittal,the application
will be considered abandoned and the fees will be forfeited.
Print Nam"� I ML V
Date 0-a�-L e Si,-nature
Residential Structures
For Office Use
Area Description (SQ FT) Existing Proposed ss value
Basement
First Floor SAM
Second Floor
Covered Deck/Porch/Entry �Tf---A - 6yo
Deck(over 30"Or 2 d floor) 4a /I_'�v
Garage
Carport
Other(describe)
Area Totals A
Commercial Structures
Proposed For Office Use
Area Descriptions(SQ FT) Existing Proposed ss Value
Existing Structure (s)
Proposed Addition
Tenant Improvement?
Other work(describe)
Site Area Totals
Lot/Site Coverage Calculations
Lot Size (sq ft) Lot Coverage (sq ft) jPT-+-K(+ OY, erage (Total lot coverage lot size)
1 aaia;& 1360 -4w =-).i �4 0/&
Site C q Ft of all impervious) %of Site Coverage (total site coverage-- lot size)
aM8 3,3-:70
Mechanical Fixtures
Indicate how many of each e of fixture to be installed or relocated as part of this project.
Air Handler Size: I #
C�'5tA Haz/Non-Haz Piping Outlets:
Appliance Exhaust Fan # Heater(Suspended, Floor,-Recessed wall) #
Boiler/Compressor # Heating/Cooling appliance #
repair/alteration
Evaporative Cooler(attached, not # Pellet S tove/Wood-burning/Gas #
portable) as Stove/Gas Cook Stove/Misc.
Fuel Gas Piping #of Outlets: Ventilation Fan,single duct # Zi
# Ventilation System #
Forced Air Unit
Furnace/Heat Pump
Plumbing Fixtures
Indicate how many of each type of fixture to be installed or relocated
Plumbing Traps # Fuel gas piping #of Outlets:
Water Heater # Medical gas piping #of Outlets:
Water Line # Plumbing Vent piping #
Sewer Line # Industrial waste pretreatment
Other(describe):
T:\BUILDING\APPLICATION FORMS\Current BP Application\Building Permit 4-17-13.docx
M
Electrical Information Form
Public Works&Utilities Department(360)417-4700
City Electrical Inspector(360)417-4735
Please complete and return to Public Works& Utilities Department
Name 1AL
7ermanent service:
ss of
P '71y
ame and address of party Street )
responsible for permanent City/ State/ ZIP: �5F—j ul
ervice billing? Daytime Phone:91c\-W Home Phone: B. BC61-XIS A
(if other than above)
Site contact: Name: Title:
Daytime Phone:
Contractor: Name: Company:
Daytime Phone:
Electrician: Name: Compan.y:
Daytime Phone:
Excavator: Name: Company:
Daytime Phone:
M El Existing NNew
Single-family residence OlMulti-family residence; of units
0 Commercial E]Subdivision; #of lots
[I Overhead service El General service
El Underground service 0 Other:
Description of work:
Street address/lot number:
Nearest cross street:
Desired connection date:
Electrical transformer serving property is: F1 on a pole on the ground
r'AfN
Total square footage: 110 TV - sq. ft. Main disconnect size: 0100 amps
Voltage: _N120/240 1ph 0120/208 3ph [:1277/480 3ph
E1120/240 3ph 0480 3W 3ph E Other
'KStandaid residential loads (Lighting, refrigerator, dishwasher, washer)
Check all that apply: A/C Q!/ 'N Range/Oven El Hot Tub
Q ton)
XCIothes Dryer �<Heating El Pumps (_Hp)
El No Load Change MWater Heater El Elevator(_Hp) El Other
Please provide a copy of the following:
*Detailed plot plan (.dwg or dxf format mandatory for subdivisio n s).
*Electrical one-line drawing showing the service entrance panel and location.
*Connected load data.
'�;ize and locked rot2E:Lmps o all motors over 50hp.
[A7ppricant's Signature: Date:
MAIL OR DELIVER COMPLETED FORM TO: 321 E 5TH STREET; PORT ANGELES, WA 98362
FAX TO: 360-417-4711
WS
Information form.xIs WF
forl�
R�vlsed 1-15-09
ui
LOT 14 7' SMACK
Lu
POW H
79 SC.FT.
DE I z
left
43,
ic
rh
PROPOSED SINGLE FAMILY RESIDEN7CE
1135 SQ.Fr.
WIVE/JDEWALK
903 Sf.FT.
43.0'
7' SMACK
126.08'
PLOT PLAN
6300 SQ. Fr.LOT
2220 SQ. FT.IMPERVIOUS SURFACE
35%LOT COVERAGE
r FIREPLACE CHIMNEY
19
RAISED FLOOR OVER STAIRS
OPTIONAL VAULTED ar
CIA OPEN R, L OR A L
'7,)
lt-�VER UILD�
kApr-'A -F URN.DU
'ft>TOP ptAT9 DFSLW TiLusg .0-0.
T 0 .
Al
ORDER TRUSS
USS, 24"O.C.
15 -0
SECOND FLOOR ROOF,PLAN
MFG. TW;S, 2W' O.C. SCALE 1AV V-0"
6'-a' 14'-0"
6' 24'-
6'-2"
4'-(Y'
vti
4040 SL TOP AT 606MSGb 82"
DM
SINK DW
WOOD BURNING FIRE-PLACE
Lu
KrTCHEN
u- z
GREAT ROOM
4! 7 a.
a.
-a. 8'-6" 4'-2" 15'-4"
'Yk(.
FLUSH 807TOM OF
- R ri------ A4:ESS
AU-8 _ny&
lo BarLom OF SUB-FLOOR
i-Vi-
2868 PK
nsi) ix
2668
V V-6.1
50CFM 3'-4" _j in
15'-6" U)
%
;c F 0
A19 50C
511rl�fa i. in
"C' K26'68 Cfl -?,k sri'os
S17, au g_'%;
H.
�868 FIRE DRO ED SM )68 050 SL, T( 4
MEC ON FLOOR tt\ )P AT 8
lix 0,-L 5r.41A( Hot. pw,)t3 q;&19AII-)
7 -11
2" 6' 0"
Ln
CONC. P
tf*-L 403R,i�� Vt r-1/4(6 L r, MI
4w��_�5�'_' ,V�_ ____F ro
3112)0 4 'p. em 3��Ajllj;fLL STLIOE - ��Vbj,4,49.
-1 : bPOPPEb BEAM
FLL H BEAMS- - fc.e_tjr;.T \I-BUILT UP,
i)eq/0 Refif-fvt POST W1
20._01.
GIRDER TRUSS
GARAGE
19.-5.1
x 21'-9"
5/8"GWB ON CLG,1/2"GWB ON WAS
------------------
F
Prescriptive Energy Code Compliance for All Climate Zones in Washington
Project Information Caxt(act Informati.on
This project will use the requirements of the Prescriptive Path below and incorporate the
the minimum values listed. In addition, based on the size of the structure,the appropriate
number of additional credits are checked as chosen by the permit applicant.
Authorized Representative O'V Date
11
All ClimAle Zones
R-Valu.ea U-Factor'
Fenestration U-Factor b n/a 0.30
Skylight U-Factor Cb.e n/a 0.50
Glazed Fenestration SHG n/a n/a
Ceiling 4Y. 0.026
Wood Frame Wa Ill.kJ 21 int 0.056
Mass Wall R-Value' 21/21 h 0.056
Floor 309 0..029
Below Grade Wa llc,k 10/15/21 int+ 0.042
S d - ILI=
lab R-Value & Depth 10, 2 ft I n/a
*Table R402.1.1 and Table R402.1.3 Footnotes included on Page 2.
Each dwelling unit in one and two-family dwellings and townhouses, as defined in Section 101.2 of the
International Residential Code shall comply with sufficient options from Table R406.2 so as to achieve the
following minimum number of credits:
F-11. Small Dwelling Unit: 0.5 points
Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration
area. Additions to existing building that are less than 750 square feet of heated floor area.
Z2. Medium Dwelling Unit: 1.5 points
All dwelling units that are not included in#1 or#3, including additions over 750 square feet.
03. Large Dwelling Unit: 2.5 points
I Dwelling units exceeding 5000 square feet of conditioned floor area.
Table R406.2 Summary
Option Description Credit(s)
la Efficient Building Envelope la 0.5
lb Efficient Building Envelope lb 1.0
1c Efficient Building Envelope 1c 2.0
2a Air Leakage Control and Efficient Ventilation 2a 0.5
2b Air Leakage Control and Efficient Ventilation 2b 1.0
2c Air Leakage Control and Efficient Ventilation 2c 1.5 El
3a High Efficiency HVAC 3a 0.5 El
3b High Efficiency HVAC 3b 1.0
3c High Efficiency HVAC 3c 2.0
3d High Efficiency HVAC 3d 1.0
4 High Efficiency HVAC Distribution System 1.0
5a Efficient Water Heating 0.5
5b Efficient Water Heating 1.5
6 Renewable Electric Energy 0.5 200 kwh 0.0
Total Credits 0.00
*Please refer to Table R406.2 for complete option descriptions
http://www.energy.wsu.edu/Documents/2012�/�2ORes`/`2OEnergv.pdf
Table R402.1.1 Footnotes
For SI: 1 foot .= 304.8 mm, ci .= continuous insulation, int .= intermediate framing.
a R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity which is
less than the label or design thickness of the insulation, the compressed R-value of the insulation from
Appendix Table A101.4 shall not be less than the R-value specified in the table.
b The fenestration U-factor column excludes skylights. The SHGC column applies to all glazed fenestration.
Exception: Skylights may be excluded from glazed fenestration SHGC requirements in Climate Zones 1
through 3 where the SHGC for such skylights does not exceed 0.30.
'; "10/15/21.+TB" means R-10 continuous insulation on the exterior of the wall, or R-15 on the continuous
insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the
basement wall at the interior of the basement wall. "10/15/21.+TB" shall be permitted to be met with R-13
cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or
exterior of the wall. "10/13" means R-10 continuous insulation on the interior or exterior of the home or R-
13 cavity insulation at the interior of the basement wall. "TB" means thermal break between floor slab and
basement wall.
d R-10 continuous insulation is required under heated slab on grade floors. See R402.2.9.1.
e There are no SHGC requirements in the Marine Zone.
f Basement wall insulation is not required in warm-humid locations as defined by Figure R301.1 and Table
R301.1.
' Reserved.
h First value is cavity insulation, second is continuous insulation or insulated siding, so "13.+S" means R-13
cavity insulation plus R-5 continuous insulation or insulated siding. If structural sheathing covers 40 percent
or less of the exterior, continuous insulation R-value shall be permitted to be reduced by no more than R-3 in
the locations where structural sheathing is used to maintain a consistent total sheathing thickness.
The second R-value applies when more than half the insulation is on the interior of the mass wall.
For single rafter- or joist-vaulted ceilings, the insulation may be reduced to R-38.
k Int. (intermediate framing) denotes standard framing 16 inches on center with headers insulated with a
minimum of R-10 insulation.
I Log and solid timber walls with a minimum average thickness of 3.5 inches are exempt from this insulation
requirement.
Table R402.1.3 Footnote
a Nonfenestration U-factors shall be obtained from measurement, calculation or an approved source or as
specified in Section R402.1.3.
L-E
Xi�-
+
All
Taft-,"
AL,
L-L
1 lj
�4
�TP4
L 1
7
i I JULLLI
_LJ
L
L
-4
4--
S-K _C�
+
t -T
36
H W- 1 ij J.HJ7,11"
H-Q
4--7& r4-
4-
_LIL
_Lj__-AL
1-4
1 4--
t
1-4-
1_4
L
............
_4_4_
F7
-1
t
FE-, 17
-4-4-
--j
7
I-A LI.-i-IL
tj
-4 4----j-_
�L _J
-1-4
-17
4 lu
F
.71
1 j I
17
4r_1 I
ILI
fit f
IF -1k, +T
Tt
it
TI
-1H
4- J_�
44 4
-4-H-4-
_41
-4-a-
-T
H
j
i—A
4-4-
T T-
4 T f t--7
L
-i _J
IF
-1- J,
-1-4-i -A-L
+
i---- L
-,-tot
L-4-
-4-4-
i
-4
F-�
-j T
1-4-L
L
L-4-4-4-4--i- I
-4-
4
T
T-1
j
J, L
�--L L T
T,
++
L
LP
i T
+
-4 LL
4
-4-
- 4
--7
�-4 4 --i-H 4
T
it
-op
-ji
f
744
i-La- i
-4.
141-4
"-L-'-—ILL
4
I .-H
L
-!Lf�-J
-7—1 --4-4-
4--- 4-
-L T
-4-
17 -54-
4-1-
12
s L
A�
4-+j
-FT-i -T
4
lulfrl-
4
[77 1
4 LL'L
-4L
4---L-
L-A
14
F
T-
L
it i
=,:,zk,
-4— Ji
4
lj��,,�
t
71-T
4
-J r
-T-
J-4-t
4f
T
-4--
it it
__T
4-A L
LL
L
L LI
UL
L L
-4
4-1
�Iz
71
L
�U_L'
t---
1L(j�L
-44
_-A
-TI H -7 t
J
4-
L
-Tf-=T i'J F�
4-4- 4 JI-1 L-L
'K-F L
Ll
_1 L--i
L
'L
IJ i _L_I L-1.
L
+4
It
L-,-I
_4L �4_ Am6p
t
t
__T
UP r
t
4_4 1_4
----------
4--
T-T�t-
4--i-
1-1 N
-7- T
P
1-4- i TH
-Z'Li,
1 7
L _j_/j I
L
I I T 1-1-T-7-
_4� 4
FT :
-4®R
M-a
4m 4-
_4 I
L-4-11,1
JL
r
H i
tilt
Z;l
A
J__
::4tT
if
A,
rlo�
FT
L 41
4-L444
------ _Lj
4_11
�--r T-
-T I
_4+f
J-4
=4=4_7�
17
_tt
TT
_T i
T
ir- r--Tr T
-Ell i
f 4-4-
ji
I
-T-I 11 1
_T I
r-T
7L
4 1-,q
I
-rT
4-
Pt
fVi
--T -P-T-7+4
T�
+
+
L
4- -J -A
F T-t--�-
T
--T -r-F-1-I-
J-7-ELL
1 A-1- -------
H I LH
-T.
0-7
T 4-
7 7 Ti-
4-4�!
7s,
-11H
Tj
-T-
A-
4 1-
46
4�-
I
I F—I'l- TF
4
if I i ;
4�! J-11
-4-4--1
FT
44-
4
-4
44-i
L
T-
7'
--4
OJ
4�
C-5'C1 '1 1
-F7
H44-4
L 1
L
-.4-42s4-A
-4-4. "e't
—t--L�-4
T
T
-4-
-4�-Ii, -Tt
1 j IL
41-
iFT-t/
L + -4
IL Ri 1 1
J
t
Li 1
8- fill
r T-T-T—'.-i
57
A
V
-T-
41-
it
if
F(14
T
F--T
T-7
L I L-1
ls�
7
1 It
r
ILA
&4��ds
YE-4-
7
LH-T7.
t
ir
4-4-
--14 1
4-L
)TZ 4
-L I-J
'I--T
-T 1
-44 t
I if
if --f-+
44-4-
-L4
i ; till . ,
if
trT
L I
_T- i-i-T
Ft
_7�--I_j
i _1_1
L-1
41-w
7-r-_ t
:L-V
I T I
-1 4_1
-4-
'4
I it -t-I
jT
177
14 1 LA 1 1
4�27i gr�
4-4---4 —1 i A
_71 42
T-4---4
4-1 �-�4
-r4
ILI
4-
1--i T_
7_ --A 4- - -----
I I it t
17-
I j
4--4-
PH
j4. +1
Tr
T7
(dt
_T
if PH-
I I it Ip I I
tit
if I
IXF.X�)-
.-L4-
it
if
if I I
it
-4-t
F7'
it
it
71
It if I it
-T�-1411t
ILI
-TE
41
T
E-A
th HY ff Q III
_L`_
+
I it
71--71-11-1 1 -_7
44-LILL
OW T
4
44*017 4
+
PT 1 FAT I
t+
ar __-�t
L-L
'61
i HL
if V_
14
T T, I
1+0
T t
T -
-161 Vm - -T-1 L :J
F—I
:44-4+
4- 1
-01
+
htt
J1
-71E
Q_' 1
4itt . 5 1 ' i ' - - T-1
tin
L-I,- I
7711TIT 7 AT'
it
will 0951 too
Alt� . . . . .
4.1 _-4.
4_1 LI
J±fj Of
Tin
+ +1 1j"
:F E_
MT
A..
dt_:71-11h
±0
it
4-17-
1
±dl 1 1 1 IRL-IF
lit
4�
Tt WAY A
_1_4 Hl�'i _1 II
4 _44-44 1
it i
it dit —I I
+4,-
4-- -44
it
ITIL,
+it
I t i+T 1 i
L LL
-----------
AL
it
---------- H-1
V 011
-L-4--4
-4 T-f-
it
ITE
LJL
- d i__i---
?411
KA
-ffff+4 it
AT
404f aT 44-
40
4 4
-4- -T] it
IT F:1�
TIE 4�__H
Kt-
it I 1 11 4 1 j
_Lt t-4-
7 7T
F7
MecaWind Pro v2 . 2 . 3 . 5 per ASCE 7-10
Developed by MECA Enterprises, Inc. Copyright www.mecaenterprises.com
Date 11/20/2013 Project No. 13303
Company Name Zenovic & Associates Designed By SRH
Address 301 East 6th Street, Suite #1 Description SFR AT GRANTS VIEW LANE, PORT
City Port Angeles Customer Name R&M BUILDERS
State WA Proj Location GRANTS VIEW LANE, PORT ANGELES
File Location: C:\Users\SRH\AppData\Roaming\Mecawind\Default.wnd
Directional Procedure Simplified Diaphragm Building (Ch 27 Part 2)
Basic Wind Speed(V) 130.00 mph
Structural Category II Exposure Category C
Natural Frequency N/A Flexible Structure No
Importance Factor 1.00 Kd Directional Factor = 0.85
Damping Ratio (beta) 0.01
Alpha 9.50 Zg = 900.00 ft
At 0.11 Bt 1.00
Am 0.15 Bm. - 0.65
Cc 0.20 1 - 500.00 ft
Epsilon 0.20 Zmin 15.00 ft
Slope of Roof 4.99968 : 12 Slope of Roof(Theta) = 22.62 Deg
Ht: Mean Roof Ht 21.60 ft Type of Roof = GABLED
RHt: Ridge Ht 24.21 ft Eht: Eave Height = 19.00 ft
OH: Roof Overhang at Eave= 2.00 ft Overhead Type = OH w/ soffit
Bldg Length Along Ridge = 35.00 ft Bldg Width Across Ridge= 21.00 ft
Gust Factor Calculations
Gust Factor Category I Rigid Structures - Simplified Method
Gustl: For Rigid Structures (Nat. Freq.>l Hz) use 0.85 = 0.85
Gust Factor Category II Rigid Structures - Complete Analysis
Zm: 0.6*Ht = 15.00 ft.
lzm: Cc*(33/Zm)^0.167 0.23
Lzm: 1*(Zm/33)^Epsilon 427.06 ft
Q: (1/(1+0.63*((B+Ht)/Lzm)^0.63))^0.5 0.93
Gust2: 0.925*((1+1.7*lzm*3.4*Q)/(1+1.7*3.4*lzm)) 0.89
Gust Factor Summary
Not a Flexible Structure use the Lessor of Gustl or Gust2 0.8�
Table 26.11-1 Internal Pressure Coefficients for Buildings, GCpi
GCPi Internal Pressure Coefficient +/-0.18
MWFRS Diaphragm Building Wind Pressures per Ch 27 Pt 2
All pressures shown are based upon ASD Design, with a Load Factor of .6
See fig 27.6-2 for
pampet wind Roof Pmoures
prMUM SceTbbleVA-2
Mean mof ht.
Ph
Wind
Won Pmswr-s
r::�
SeeTableZ7.5-2 h
pol 1 1 Plan
Mvatian
A
h
aA
Gabled Roof
MWFRS Pressures for Wind Normal to 35 ft wall (Normal to Ridge)
WALL PRESSURES PER TABLE 27.6-1
L/B: Bldg Dim in Wind Dir / Bldg Dim Normal to Wind Dir 0.60
h: Height to top of Windward Wall 19.00 ft
ph: Net Pressure at top of wall (windward + leeward) 21.85 psf
pO: Net Pressure at bottom of wall (windward + leeward) 21.61 psf
ps: Side wall pressure acting away from wall = .54 * ph = -11.80 psf
pl: Leeward wall pressure acting away from wall .38 * ph = -8.30 psf
pwh: Windward wall press @ top acting toward wall ph-pl 13.55 psf
pwO: Windward wail press @ bot acting toward wall pO-pl 13.31 psf
ROOF PRESSURES PER TABLE 27.6-2
h: Mean Roof Height 21.604 ft
Lambda: Exposure Adjustment Factor 1.000
Slope: Roof Slope 22.62 Deg
Zone Load Casel Load Case2
Psf Psf
---- ---------- ----------
1 -13.87 7.97
2 -13.94 -6.64
3 -21.43 .00
4 -19.06 .00
5 -15.65 .00
Note: A value of '01 indicates that the zone/load case is not applicable.
ROOFOVERHANG LOADS (FIGURE 27.6-3) :
LOAD CASE 1:
Povhl: Overhang pressure for zone 1 - -10.41 psf
Povh3: Overhang pressure for zone 3 - -16.07 psf
LOAD CASE 2:
Povhl: Overhang pressure for zone 1 - 5.98 psf
Povh3: Overhang pressure for zone 3 - .00 psf
MWFRS Pressures for Wind Normal to 21 ft wall (Along Ridge)
WALL PRESSURES PER TABLE 27.6-1
L/B: Bldg Dim in Wind Dir / Bldg Dim Normal to Wind Dir 1.67
h: Height to top of Windward Wail 24.21 ft
ph: Net Pressure at top of wall (windward + leeward) 20.83 P3f
pO: Net Pressure at bottom of wall (windward + leeward) 20.06 psf
ps: Side wall pressure acting away from wall = .61 * ph = -12.64 psf
pl: Leeward wall pressure acting away from wall .31 * ph = -6.39 psf
pwh: windward wail press @ top acting toward wall ph-pl 14.44 psf
pwO: Windward wall press @ hot acting toward wall pO-pl 13.67 psf
ROOF PRESSURES PER TABLE 27.6-2
h: Mean Roof Height 21.604 ft
Lambda: Exposure Adjustment Factor 1.000
Slope: Roof Slope 22.62 Deg
Zone Load Casel Load Case2
Psf Psf
---- ---------- ----------
1 -13.87 7.97
2 -13.94 -6.64
3 -21.43 .00
4 -19.06 .00
5 -15.65 .00
Note: A value of '0' indicates that the z�one/load case is not applicable.
ROOF OVERHANG LOADS (FIGURE 27.6-3) :
LOAD CASE 1:
Povhl: Overhang pressure for zone 1 -10.41 psf
Povh3: Overhang pressure for zone 3 -16.07 psf
LOAD CASE 2:
Povhl: Overhang pressure for zone 1 5.98 psf
Povh3: Overhang pressure for zone 3 .00 psf
Total Base Reaction Summary
Description Fx Fy FZ Mx MY MZ
Kip Kip Kip K-ft K-ft K-ft
--------------------------------------------------------------------------------------
Normal to Ridge Walls+Roof +GCpi .0 14.5 11.4 129.3 .0 .0
Normal to Ridge Walls Only +GCpi .0 14.5 .0 137.6 .0 .0
Normal to Ridge Walls+Roof -GCpi .0 17.1 -0.2 160.0 .0 .0
Normal to Ridge Walls Only -GCpi .0 14.5 .0 137.6 .0 .0
Normal to Ridge Walls+Roof MIN .0 .0 .0 .0 .0 .0
Along Ridge Walls+Roof +GCpi 9.5 .0 16.2 .0 -125.9 .0
Along Ridge Walls Only +GCpi 9.5 .0 .0 .0 -105.8 .0
Along Ridge Walls+Roof -GCpi 9.5 .0 .0 .0 -105.8 .0
Along Ridge Walls Only -GCpi 9.5 .0 .0 .0 -105.8 .0
Along Ridge Walls+Roof MIN .0 .0 .0 .0 .0 .0
Notes Applying to MWFRS Reactions:
Note (1) Per Fig 27.4-1, Note 9, Use greater of Shear calculated with or without roof.
Note (2) X= Along Building ridge, Y = Normal to Building Ridge, Z = Vertical
Note (3) MIN = Minimum pressures on Walls = 9.6 psf and Roof = 4.8 psf
Note (4) MIN area is the area of the surface onto a vertical plane normal to wind.
Note (5) Total Roof Area (incl OH Top) 947.91 sq. ft
Note (6) LC = Load Case (Some pressures can be zero, ref ASCE 7-10 Ch 27 Pt 2)
af-
RDn-f-not It
showu
2: 1 :2 2: 1 2
4
r
a; L3,
walk Gable Ro-of 7<0-z--4-5t
F'W�� MEMBER REPORT 2ND FLOOR FRAMING,FLUSH BEAM AT STAIRWAY FAILED
. 9FORTE " 1 piece(s) 3 1/2" x 12" 24F-V4 DF Glulam
This product failed due to an excessive uplift of-2731 lbs at support 1.
Overall Length: 19'7"
0 0
4'3" 15'4"
Fil F2] [31
All locations are measured from the outside face of left support(or left cantilever end).All dimensions are horizontal.
i5esign Results Actual @ Location L61','Load:'Combination(Pattern) System Floor
Member Reaction(lbs) 8596 @ 4'3" 12513(5.50") Passed(69%) 1.0 D+1.0 L(All Spans) Member Type Flush Beam
Shear(lbs) 4155 @ 5'5 3/4" 7420 Passed(56%) 1.00 1.0 D+1.0 L(All Spans) Building Use:Residential
Pos Moment(Ft-lbs) 9704 @ 13'1 1/2" 16800 Passed(58%) 1.00 1.0 D+1.0 L(Alt Spans) Building Code:IBC
Neg Moment(Ft-lbs) -11989 @ 4'13/4" 12950 Passed(93%) 1.00 1.0 D+1.0 L(All Spans) Design Methodology Aso
Live Load Defl.(in) 0.283 @ 12'6 1/4" 0.375 Passed(L/636) 1.0 D+1.0 L(Alt Spans)
Total Load Defl.(in) 0.360 @ 12'6 5/16" 0.750 Passed(L/500) 1.0 D+1.0 L(Alt Spans)
Deflection criteria:LL(L/480)and TL(L/240).
Bracing(Lu):All compression edges(top and bottom)must be braced at 18'6 5/8"o/c unless detailed otherwise.Proper attachment and positioning of lateral
bracing is required to achieve member stability.
Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L 12'1/2".
Cribcal negative moment adjusted by a volume factor of 1.00 that was calculated using length L 7'13/16".
The effects of positive or negative camber have not been accounted for when calculating deflection.
The specified glulam is assumed to have its strong laminations at the bottom of the beam.Install with proper side up as indicated by the manufacturer.
Applicable calculations are based on Nos 2005 methodology.
Bearing Length
"ds�*s�ports(lbs)
red
Supports Total Available Re Total Accessories
'qui
1-Column-DF 3.50" 2.25" 1.50" -480 494/- 494/-2731 1 1/4"Rim Board
2-Column-OF 5.50" 5.50"——3,78" 1855 6742 8597 None
3-Stud wall-OF 5.50" 4.25" 1.53" 729 2671 3400 1 114"Rim Board
-Rim Board is assumed to carry all loads applied directly above it,bypassing the member being designed.
Tributary D
'00) oninients,
Loads Location Width (q. i, ,�'c
1-Uniform(ESE) Tto 19'7" 10'6" 10.0 40.0 Residential-Living Areas
2-Uniform(PSF) 0 to 3' 5'6" 10.0 40.0
,Weyerhaeuser Notes — 777777,11, SUSTAINABLE FORESTRY INITIATIVE
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software.Refer to current Weyerhaeuser literature for installation details.
(www.woodbywy.com)Accessories(Rim Board,Blocking Panels and Squash Blocks)are not designed by this software.Use of this software is not intended to
circumvent the need for a design professional as determined by the authority having JurisclictJon.The designer of record,builder or framer is responsible to
assure that this calculabon is compatible with the overall project.Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable
forestry standards.
The product applicalion,input design loads,dimensions and support information have been provided by Forte Software Operator
11/2112013 8:16:14 AM
Forte v4.1,Design Engine:V5.7.0.245
Scott Headrick 13303
Zeno\Ac&Assoc. R&M BUILDERS
(360)417-0501 GRANTS VIEW LANE,PORT ANGELES
scott@zenoAc.net
Page 1 of 1
F 0 R T E MEMBER REPORT 2ND FLOOR FRAMING,FLUSH BEAM OVER GARAGE PASSED
1 piece(s) 3 1/2" x 9" 24F-V4 DF Glulam
Overall Length: 10'6"
+
0
0
10-6"
in
All locations are measured from the outside face of left support(or left cantilever end).All dimensions are horizontal.
Design Results Actual @ Location Allowed Result LDF Load:Combination(Pattern) System Floor
Member Reaction(lbs) 2604 @ 2" 4922(2.25") Passed(53%) -_ 1�0 D+1.0 S(All Spans) Member Type Flush Beam
Shear(lbs) 2053 @ V 1/2" 6400 Passed(32%) 1.15 1.0 D+1.0 S(All Spans) Building Use:Residential
Pos Moment(Ft-lbs) 5726 @ 4'7 7/8" 10868 Passed(53%) 1.15 1.0 D+0.75 L+0.75 S(All Spans) Building Code:IBC
Live Load Defl.(in) 0.097 @ 4'11 1/8" 0.252 Passed(L/999+) -- 1.0 D+0.75 L+0.75 S(All Spans) Design Methodology ASO
Total Load Defl.(in) 0.257 @ 5'1/8" 0.504 Passed(L/470) 1.0 D+0.75 L+0.75 S(All Spans)
Deflection criteria:LL(L/480)and TL(1-1240).
Bracing(Lu):All compression edges(top and bottom)must be braced at 10'13/4"o/c unless detailed otherwise.Proper attachment and positioning of lateral
bracing is required to achieve member stability.
Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L=10'1".
The effects of positive or negative camber have not been accounted for when calculating deflection.
The specified glulam is assumed to have its strong laminations at the bottom of the beam.Install with proper side up as indicated by the manufacturer.
Applicable calculations are based on NDS 2005 methodology.
Bearing Length Loads to Supports(lbs)
Supports Total Available Required Dead Floor Snow I Accessories
Live
1-Stud wall-DF 3.50" 2.25" 1.50"_ 1486 283 1179 .2948 1 1/4"Rim Board
2-Hanger on 9"DF beam 3.00" 1 Hanger� 1.50" 1001 318 371 1690 See note
-Rim Board is assumed to carry all loads applied directly above it,bypassing the member being designed.
At hanger supports,the Total Bearing dimension is equal to the width of the material that is supporting the hanger
See Connector grid below for additional information and/or requirements.
Connector:Simpson Strong-Tie Connectors
Supp I ort Model Seat Length Top Nails Face Nails Member Nail;7_1 Accessories
2-Face Mount Hanger LUS410 2.00" N/A 8-16d common 6-16d common used in
double shear
Tributary Dead Floor Live Snow
Loads Location Width (0.90) (1.00) (1.15) Comments
1-Uniform(PLF) 0 to 5' N/A 280.0 40.0 300.0 Residential-Living Areas
2-Uniform(PLF) S'to 10'6" N/A 103.0 53.0 -
3-Point(lb) 5- N/A 443 110 50
Weyerhaeuser Notes SUSTAINABLE FORESTRY INITIATIVE
ly-1
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software.Refer to current Weyerhaeuser literature for installation details.
(www.woodbywy.com)Accessories(Rim Board,Blocking Panels and Squash Blocks)are not designed by this software.Use of this software is not intended to
circumvent the need for a design professional as determined by the authority having jurisdiction.The designer of record,builder or framer is responsible to
assure that this calculation is compatible with the overall project.Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable
forestry standards.
The product application,input design loads,dimensions and support information have been provided by Forte Software Operator
-Job N.6
tee,
F6rte "are, Cperat��..,' 11/21/2013 8:45:52 AM
Scott Headrick 13303 Forte v4.1,Design Engine:V5.7.0.245
Zenom&Assoc- R&M BUILDERS
(360)417-0501 GRANTS VIEW LANE,PORT ANGELES
scott@zenoAc.net Page 1 of 1
F T
7 T T-1-J
7,
-,J
-4
-7T
J, ------------ �—jj I-L L
I L I
7
L-4- .-I
j-L-,,, J-- --L L
j
-7 7 ,
L
77-r
T . i .
-T
4-1
j
t , f , i
L
F
4-
r 1 --4-4�
LL
-- ------LL
fUNAL
... ... ... ...
L�-LL—
L
-4-
-----------
-j—
-44
-L-4-
-4-
L
4
4
-4-
j L
it
71 7
r T
-4-
-7
7
T-
-4-
+
L
et* T
4A
T(At
-4
--J
-i4
L L±
-T- _7
t-F
r+,-71
4
LI
t
T-T-
-4 t-
-T-
4
T
LA.
-J�I
FT
T
L L
4-
0 L-J", T-I
ALLL 1-1
f
T--I-t
T-
f i
J-;
i�Jl
o/n -ie
T--
L
44-
-T I
-I-T
f-4-4-4-4-
i-J-
4-
-4-4-
Ll
X�l
t 4
-1 dll TH
Jr7/
--4
�--r T T-
-4-4-11--,
-�T---r-
t .
1 4
HF
4�-
-I-L--- L 1 .
7-
i -T-
-4-4---1-4
--4-4- 4
4-
&T
-T
-T
-4-4--i-4-,
4---4-��-
--7--T—i
A
4�ffa-
I T i 1, 1 T 1 1 El i i -
4-LL -r� --T
1 41
17
T
-WN 4-Hi
L
IL
F71 JIFIE, T,
;Ti
-44-
-T T
L 4-�
-4-4-4
L----------
L
j i
77,
Ll
Uc 7-j
T
t
i L
4-
-4
IA
-,i rr
---�t4
4-4-
F-F
7
�E I - -----
k- t-7
LA
L
-L-J i
F44-1 41L, -7 T
-4t- 3,5 VI;r
t -7
f-4--
LL�
J,
14-[--L
J, 4-i-
4-
4--
L-1 -A-
IM
i 1 ILI
1 t 1
T
J-- 4
+
+
L L J
-T--1 1�r
iS I
-,�j -j
L
If
1-LL
+
JA�-
if
k IE
Lj
L
7-7
�-4-j
...........
4 1
F
-LL
-4
4y
ILL- W-Tvl�-
if
-f-4
J
T
.4 111441
4-
-7-
-T
. ........I
11-1-J i
4
L-L
Alit
: Aj
_-L-V:j
if
J-L I,j -4
45NIit
77
I I 1 7 1
ffljq#i f::[,
P �
-4-4"
ILETL
it
It
4L
1-1-r-H
7
LT- 4-+
-fV1 I
_j
it
T
4
4-44--
it I I
T-
4-11
.......... T-
)447
17 it
-A
I I -j -T
T 1
t
t I I I
-41
L Lt
2X
L L
---------- -
it
-7-7
-4 -1
LT
M it I I'I LIU� QZ:4
-Vi
4-4-
it It 1A
-A-
L---I J--L 4#
-7-1
31.
4H-j
i zrl tj (L
437-1 L--
IT: TP
4
411
Ll
-4-1-T
T_r
_7 T
'I T-T-T--T
t
4;
t 7LI
T__r------r-"
I if
ti
Jr-4-t
4
7-1
Ld
j L J1,
N-1
L_L4
f
T
-1-4 41-1'
_4
1 57
j 1-71
-IF
Ir
--l't T T TJ It t7l
i -7- 44-
4__
'T
_L -A
L L.
L
_T
4-
7 if
if
tj
H H
_LJ 77--r
L
44-T-'
'-S_7 6�
-4-
44, 44
Arl,
if
17-
d-L
14,
1L 1 1
T4
Jl
i if
-7/ /11
7
t
�T - ------
--L 4
if t I I
I F_
4444
TLIT-Pl-
T �7 -4_
il--: 1_4 L J -4'--,!
LLTT� __�J_'LL
f
TI
1-41 4
H 4
4-_
1 M
T-17-
T IT-
_J
__7 71 F
_7 JO: LLL
A_i
4-
I'T
4_1
Tic:
__4
MT
4b ------
T 1_1
T I-!
1-T --I
-7 T'
1-7
_T
11 _T
i
t-t+
J4 Il-_T
+
I W-i
F 7 1 1 1 1 1 I-F-:
I I I I I i T I I
T I i I I
-T
�t7 Hitf Ot 1.
I J
44-
if _('a
T I I
It -1-11
tZ
T7
v -t4--
if F I
it
14-
-4-4-
T _Tt_ TT,
J,
Ll L
T
Li
1-IL-H-7- T J
�j
TT-T-: 7 4-1
L
it T-1
i it
it
it I
J.T
t
1-4
j
EL
it
T
-44
4-
TV
T-
L-1 1-1
4
1- 4
4
J -LL;4- i -i 4 TIT
L
T-1
�-d
-I� 71
-44i 4-4 4-------
Ft,
ti -t-.-lr_-
4-
4
41 1
TT-
F T
-T
-4-
-+4
it
5211
L
+
t H H
MecaWind Pro v2 . 2 . 3 . 5 per ASCE 7-10
Developed by MECA Enterprises, Inc. Copyright www.mecaenterprises.com
Date 11/20/2013 Project No. 13303
Company Name Zenovic & Associates Designed By SRH
Address 301 East 6th Street, -Suite #1 Description SFR AT GRANTS VIEW LANE, PORT
City Port Angeles Customer Name R&M BUILDERS
State WA Proj Location GRANTS VIEW LANE, PORT ANGELES
File Location: C:\Users\SRH\AppData\Roaming\mecaWind\Default.wnd
Directional Procedure Simplified Diaphragm Building (Ch 27 Part 2)
Basic Wind Speed(V) 130.00 mph
Structural Category II Exposure Category C
Natural Frequency N/A Flexible Structure No
Importance Factor 1.00 Kd Directional Factor = 0.85
Damping Ratio (beta) 0.01
Alpha 9.50 Zg = 900.00 ft
At 0.11 Bt - 1.00
Am 0.15 Bm - 0.65
Cc 0.20 1 - 500.00 ft
Epsilon 0.20 Zmin 15.00 ft
Slope of Roof 4.99968 : 12 Slope of Roof(Theta) = 22.62 Deg
Ht: Mean Roof Ht 21.60 ft Type of Roof = GABLED
RHt: Ridge Ht 24.21 ft Eht: Eave Height = 19.00 ft
OH: Roof Overhang at Eave= 2.00 ft Overhead Type = OH w/ soffit
Bldg Length Along Ridge = 35.00 ft Bldg Width Across Ridge= 21.00 ft
Gust Factor Calculations
Gust Factor Category I Rigid Structures - Simplified Method
Gustl: For Rigid Structures (Nat. Freq.>l Hz) use 0.85 = 0.85
Gust Factor Category IT Rigid Structures - Complete Analysis
Zm: 0.6*Ht = 15.00 ft
lzm: Cc*(33/zm)^0.167 0.23
Lzm: 1*(Zm/33)^Epsilon 427.06 ft
Q: (1/(1+0.63-((B+Ht)/Lzm)^0.63))^0.5 0.93
Gust2: 0.925*((1+1.7*lzm*3.4*Q)/(1+1.7*3.4*lzm)) 0.89
Gust Factor Summary
Not a Flexible Structure use the Lessor of Gustl or Gust2 0.85
Table 26.11-1 Internal Pressure Coefficients for Buildings, GCpi
GCPi : Internal Pressure Coefficient +/-0.18
MWFRS Diaphragm Building Wind Pressures per Ch 27 Pt 2
All pressures shown are based upon ASD Design, with a Load Factor of .6
See FS 27.6-2 for
Fampet wMd Roof Pressurm
MIM-M SeeTableVXP2
Moon roof ht.
Ph
VWnd
See Table V.5-2
I p
Pbn
4
Gabled Roof
pra
MWFRS Pressures for Wind Normal to 35 ft wall (Normal to Ridge)
WALL PRESSURES PER TABLE 27.6-1
L/B: Bldg Dim in Wind Dir / Bldg Dim Normal to Wind Dir 0.60
h: Height to top of Windward Wall 19.00 ft
ph: Net Pressure at top of wall (windward + leeward) 21.85 psf
pO: Net Pressure at bottom of wall (windward + leeward) 21.61 psf
ps: Side wall pressure acting away from wall = .54 * ph = -11.80 psf
pl: Leeward wall pressure acting away from wall .38 * ph = -8.30 psf
pwh: Windward wall press @ top acting toward wall ph-pl 13.55 psf
pwO: Windward wall press @ bot acting toward wall pO-pl 13.31 psf
ROOF PRESSURES PER TABLE 27.6-2
h: Mean Roof Height 21.604 ft
Lambda: Exposure Adjustment Factor 1.000
Slope: Roof Slope 22.62 Deg
Zone Load Casel Load Case2
Psf Psf
---- ---------- ----------
1 -13.87 7.97
2 -13.94 -6.64
3 -21.43 .00
4 -19.06 .00
5 -15.65 .00
Note: A value of '0' indicates that the zone/load case is not applicable.
ROOF OVERHANG LOADS (FIGURE 27.6-3) :
LOAD CASE 1:
Povhl: Overhang pressure for zone 1 - -10.41 psf
Povh3: Overhang pressure for zone 3 - -16.07 psf
LOAD CASE 2:
Povhl: Overhang pressure for zone 1 - 5.98 psf
Povh3: Overhang pressure for zone 3 - .00 psf
MWFRS Pressures for Wind Normal to 21 ft wall (Along Ridge)
WALL PRESSURES PER TABLE 27.6-1
L/B: Bldg Dim in Wind Dir / Bldg Dim Normal to Wind Dir 1.67
h: Height to top of Windward Wall 24.21 ft
ph: Net Pressure at top of wall (windward + leeward) 20.83 psf
pO: Net Pressure at bottom of wall (windward + leeward) 20.06 psf
ps: Side wail pressure acting away from wall = .61 * ph -12.64 psf
pl: Leeward wall pressure acting away from wall .31 * ph -6.39 psf
pwh: Windward wall press @ top acting toward wall ph-pl 14.44 psf
pwO: Windward wall press @ bot acting toward wall pO-pl 13.67 psf
ROOF PRESSURES PER TABLE 27.6-2
h: Mean Roof Height 21.604 ft
Lambda: Exposure Adjustment Factor 1.000
Slope: Roof Slope 22.62 Deg
Zone Load Casel Load Case2
Psf Psf
---- ---------- ----------
1 -13.87 7.97
2 -13.94 -6.64
3 -21.43 .00
4 -19.06 .00
5 -15.65 .00
Note: A value of '0' indicates that the zone/load case is not applicable.
ROOF OVERHANG LOADS (FIGURE 27.6-3) :
LOAD CASE 1:
Povhl: Overhang pressure for zone 1 - -10.41 psf
Povh3: Overhang pressure for zone 3 - -16.07 psf
LOAD CASE 2:
Povhl: Overhang pressure for zone 1 - 5.98 psf
Povh3: Overhang pressure for zone 3 .00 psf
Total Base Reaction Summary
Description Fx FY Fz Mx MY MZ
Kip Kip Kip K-ft K-ft K-ft
--------------------------------------------------------------------------------------
Normal to Ridge Walls+Roof +GCpi .0 14.5 11.4 129.3 .0 .0
Normal to Ridge Walls Only +GCpi .0 14.5 .0 137.6 .0 .0
Normal to Ridge Walls+Roof -GCpi .0 17.1 -0.2 160.0 .0 .0
Normal to Ridge Walls Only -GCpi .0 14.5 .0 137.6 .0 .0
Normal to Ridge Walls+Roof MIN .0 .0 .0 .0 .0 .0
Along Ridge Walls+Roof +GCpi 9.5 .0 16.2 .0 -125.9 .0
Along Ridge Walls Only +GCpi 9.5 .0 .0 .0 -105.8 .0
Along Ridge Walls+Roof -GCpi 9.5 .0 .0 .0 -105.8 .0
Along Ridge Walls Only -GCpi 9.5 .0 .0 .0 -105.8 .0
Along Ridge Walls+Roof MIN .0 .0 .0 .0 .0 .0
Notes Applying to MWERS Reactions:
Note (1) Per Fig 27.4-1, Note 9, Use greater of Shear calculated with or without roof.
Note (2) X= Along Building ridge, Y = Normal to Building Ridge, Z Vertical
Note (3) MIN = Minimum pressures on Walls = 9.6 psf and Roof = 4.8 psf
Note (4) MIN area is the area of the surface onto a vertical plane normal to wind.
Note (5) Total Roof Area (incl OH Top) 947.91 sq. ft
Note (6) LC = Load Case (Some pressures can be zero, ref ASCE 7-10 Ch 27 Pt 2)
Rmof not
shown
2: 1 2 2: 1 2
I t 1
4
5
Walls- Gable Roof 7<9 4-5
a
]—�q
rdmFORTE " MEMBER REPORT 2ND FLOOR FRAMING,FLUSH BEAM AT STAIRWAY FAILED
1 piece(s) 3 1/2" x 12" 24F-V4 DF Glulam
This product failed due to an excessive uplift of-2731 lbs at support 1.
Overall Length: 19'7"
0 0
4'Y 15'4"
f2]
All locations are measured from the outside face of left support(or left cantilever end).All dimensions are horizontal.
Design Results Actual @ Location Allowed Result LDF Lead:Combination(Pattern) System Floor
Member Reaction(lbs) 8596 @ 4'3" 12513(5.50") Passed(69%) -- IS)_ Member Type Flush Beam
Shear(lbs) 4155 @ 5'5 3/4" 7420 Passed(56%) 1.00 1.0 D+1.0 L(All Spans) Building Use:Residential
Pos Moment(Ft-lbs) 9704 @ 13'1 1/2" 16800 Passed(58%) 1.00 1.0 D+1.0 L(Alt Spans) Building Code:IBC
Neg Moment(Ft-lbs) -11989 @ 4'13/4" 12950 Passed(93%) 1.00 1.0.1D+1.0 L(All Spans) _ Design Methodology ASD
Live Load Defl.(in) 0.283 @ 12'6 1/4" 1 0.375 Passed(L/636) 1.0 D+1.0 L(Alt Spans)
Total Load Defl.(in) 0.360 @ 12'6 5/16" 0.750 Pat sed(L/500) 1.0 D+1.0 L(Alt Spans) 71
Deflection criteria:LL(L/480)and TL(L/240).
Bracing(Lu):All compression edges(top and bottom)must be braced at IS'6 5/8"o/c unless detailed otherwise.Proper attachment and posiboning of lateral
bracing is required to achieve member stability.
Critical posibve moment adjusted by a volume factor of 1.00 that was calculated using length L 12'1/2".
Critical negative moment adjusted by a volume factor of 1.00 that was calculated using length L 7'13/16".
The effects of positive or negative camber have not been accounted for when calculating deflection.
The specified glulam is assumed to have its strong laminators at the bottom of the beam.Install with proper side up as indicated by the manufacturer.
Applicable calculabons are based on Nos 2005 methodology.
Bearing Length Loads to Supports(lbs)
Supports To�,TAvallable Required Dead Floor Total Accessories
I-Column-DF 3.50" 2.25" 1.50" -480 49 /- 494/-2731 1 1/4"Rim Board
2251
2-Column-DF 5.501, 5.50" 3.78" 1855 6742 8597 None
3-Stud wall-DF 5.501, 4.25" 1.53" 729 2671 3400 1 1/4"Rim Board
-Rim Board is assumed to carry all loads applied direcdy above it,bypassing the member being designed.
Tributary Dead Floor Live
Loads Location Width (0.90) (1.00) Comments
1-Uniform(PSF) Tto 19'7" 10'6" 10.0 40.0 Residential-Living Areas
2-Uniform(PSF) 0 to 3' 5-6" 10.0 40.0
Weyerhaeuser Notes SUSTAINABLE FORESTRY INITIATIVE
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software.Refer to current Weyerhaeuser literature for installation details.
(www.woodbywy.com)Accessories(Rim Board,Blocking Panels and Squash Blocks)are not designed by this software.Use of this software is not intended to
circumvent the need for a design professional as determined by the authority having jurisdicton.The designer of record,builder or framer is responsible to
assure that this calculadon is compabble with the overall project.Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable
forestry standards.
The product application,input design loads,dimensions and support information have been provided by Forte Software Operator
Job Not
F6rt6 So"�na-�6�rat6r2 :f
11/21/2013 8:16:14 AM
Scott Headrck 13303 Forte v4.1,Design Engine:V5.7.0.245
ZenmAc&Assoc. R&M BUILDERS
(360)417-0501 GRANTS VIEW LANE,PORT ANGELES
scott@zeno,Ac.net Page 1 of 1
MEMBER REPORT 2ND FLOOR FRAMING,FLUSH BEAM OVER GARAGE PASSED
'aFORTE ' 1 piece(s) 3 1/2" x 9" 24F-V4 DF Glulam
Overall Length: 10'6"
0
10'6" q�
Fil
All locations are measured from the outside face of left support(or left cantilever end).All dimensions are horizontal.
,Design Resufts Actual a Location �AiIiqv� System Floor
LPF ."d:Combination(Pattern)
Member Reaction(lbs) 2604 @ 2" 4922(2.25") Passed(53%) -_ 1.0 D+1.0 S(All Spans) Member Type Flush Beam
Shear(lbs) 2053 @ V 1/2" 6400 Passed(32%) 1.15 1.0 D+1.0 S(All Spans) Building Use:Residential
Pos Moment(Ft-lbs) 5726 @ 4'7 7/8" 10868 Passed(53%) 1.15 1.0 D+0.75 L+0.75 S(All Spans) Building Code:IBC
Live Load Defl.(in) 0,097 @ 4'11 1/8" 0.252 Passed(L/999+) -- 1.0 D+0.75 L+0.75 S(All Spans) Design Methodology ASO
Total Load Defl.(in) 0.257 @ 5'1/8" 0.504 1 Passed(L/470) 1.0 D+0.75 L+0.75 S(All Spans)
Deflection criteria:LL(L/480)and TL(L/240).
Bracing(Lu):All compression edges(top and bottom)must be braced at 10'13/4"o/c unless detailed otherwise.Proper attachment and positioning of lateral
bracing is required to achieve member stability.
Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L=10'1".
The effects of positive or negative camber have not been accounted for when calculating defection.
The specified glulam is assumed to have its strong laminations at the bottom of the beam.Install with proper side up as indicated by the manufacturer.
Applicable calculations are based on NDS 2005 methodology.
Bearing Length to$uoports(Ibs)
Supports, Total Available ke4 I., sn
ui ed, 'sn Total Accessories
1-Stud wall-OF 3.50" 2.25" 1.501, 1486 283 1179 2948 1 1/4"Rim Board
2-Hanger on 9"DF beam 3.00" Hanger� 1.50" 1001 318 371 1690 See note
-Rim Board is assumed to carry all loads applied directly above it,bypassing the member being designed.
At hanger supports,the Total Bearing dimension is equal to the width of the material that is supporting the hanger
See Connector grid below for addidonal information and/or requirements.
Connector:Simpson Strong-Tie Connectors.
P is
I Face Nails Member Nails
support Model sot""", Nal
2-Face Mount Hanger W5410 2.00" N/A 8-16d common 6-16=mon used in
e Shear
Tributary De0d t "-snow
Loads Location Width igo)�
(1.iS). Comments
1-Uniform(PLF) 0 to 5' N/A 280.0 40.0 300.0 Residendal-Living Areas
2-Uniform(PLF) Tto 10'6" N/A 103.0 53.0 -
3-Point(1b) 5' N/A 443 110 50
.Weyerhaeuser Notes SUSTAINABLE FORESTRY INITIATIVE
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software.Refer to current Weyerhaeuser literature for installation details.
(www.woodbywy.com)Accessories(Rim Board,Blocking Panels and Squash Blocks)are not designed by this software.Use of this software is not intended to
circumvent the need for a design professional as determined by the authority having jurisdiction.The designer of record,builder or framer is responsible to
assure that this calculabon is compatible with the overall project.Products manufactured at Weyerhaeuser facilities are third-party certifled to sustainable
forestry standards.
The product application,input design loads,dimensions and support information�ave been provided by Forte Software Operator
11/21/2013 8:45:52 AM
Jo Notes-'
jK,
pp. Forte v4.1,Design Engine:V5.7.0.245
Scott Headrick 13303
ZenoAc&Assoc. R&M BUILDERS
(360)417-0501 GRANTS VIEW LANE,PORT ANGELES
scott@zenoAc.net
Page I of 1
CIVIL ENGINEERING
LAND SURVEYING
Eil N (0)V I cl
& ASSOCIATES RECEIVED 301 East 6th Street,Suite I
Pc t Angeles,Washington 98362
1 N C 0 R P 0 R A T E D
F0
FEB 1 1 2014 (360)417-0501
Fax(360)417-0514
CITY OF PORT 4ANGEL
.D1 IVIS10 -mail:zenovlc@olympus.net
BUILDING DIVIS10,
February 10, 2014
Mr. Patrick Bartholick
City of Port Angeles Department of Community Development
321 East Fifth Street
Port Angeles, WA 98362
SUBJECT: R & M Builders — S.F.R. and Rock Wall at 3112 Grants View, Port
Angeles, Washington — Building Permit 13-1446
Dear Mr. Bartholick:
This office has performed an inspection of the rock wall constructed on the downhill side
of the lot at the address noted above. The rock wall is approximately 5'-6' tall and is
located approximately 6' from the foundation of the single family residence. Based on
the inspection, the rock wall is acceptable as constructed and the house foundation will
be stable and not influence the stability of the rock wall. Attached is a drawing showing
the typical construction for the rock wall.
Please call me if you have any further questions on this matter.
Sincerely,
Tracy Gudgel, P.E. T
SM
Fc: JN 13303
Cc: R & M Builders
Erjv-i
6'±
FOOTING BACKFILL
FOUNDATION (WHERE
OCCURS)
ll�FILTER FABRIC (TYPAR 3401
OR EQUAL)
TAPER ROCK WALL AS
INDICATED IN TABLE TO
RIGHT WALL HT. NOM. ROCK SIZE
0 BASE
0 2' 1 1 xi
:H
2' 4' 2'X2'
4- 6- 3'x3'
QUARRY SPALL FILL
FINISH GRADE
ml
2�
4"0 PERFORATED DRAIN PIPE
(EXTEND TO DAYLIGHT)
D, 0 01/j/
ROCKERY RETAINING WALL DETAIL WA <'
NOT TO SCALE
-32777
s C/STEPo
'ONAL
FSCALE: TITLE: ROCK WALL DETAIL FOR R & M BUIL S, 3112 GRANTS WEW, PORT ANGELES, WA SHEET
NTS
DATE: ROCK WALL DETAIL
2 110
/1012014
JOB NO:
13303 CLIENT: ENOVIC & 301 E. 6TH STREET, SUITE 1
R & A4 BUILDERS PORT ANGELES, WA 98362
PHONE: (360) 417-0501
FILE: 1541 TAYLOR CUTOFF ROAD ZASSOCIATES FAX: (360) 417-0514 OF
13303 Sl SEQUIM, WA 98382 INCORPORATED EMAIL: ZENOMCOZENOMCNET