Loading...
HomeMy WebLinkAbout3630 S Aviation Place Address: 3630 S Aviation Place PREPARED 4/17/17, 8:59:52 INSPECTION TICKET PAGE 1 CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 4/17/17 ------------------------------------------------------------------------------------------------ ADDRESS 3630 S AVIATION PL SUBDIV: CONTRACTOR : PHONE : OWNER Jeff Halsey PHONE : (360) 460-5147 PARCEL 06-30-07-1-1-0250-0000- APPL NUMBER: 16-00001504 COMM NEW CONST ---------------------------------------------- ------------------------------------------------- PERMIT: BPC 00 BUILDING PERMIT - COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ PW4 01 1/05/17 RV PUBLIC WORKS STORM 1/05/17 AP January 5, 2017 12:55:43 PM rvess. January 5, 2017 12:56:22 PM rvess. BL1 01 2/01/17 JLL BLDG FOUNDATION FOOTING 2/01/17 AP February 1, 2017 10:56:08 AM jlierly. 477-0778 tomMy February 1, 2017 4:28:32 PM jlierly. BL3 01 3/08/17 JLL BLDG FRAMING 3/08/17 DA March 8, 2017 3:46:24 PM jlierly. March 8, 2017 3:49:37 PM jlierly. Interior walls separating the storage space has 411 gap near the top of wall and ceiling. verify in the code this has not changed from the spearation requirement for the separation to terminate at the under side of the ceiling or horizontal surface directly over the space. JLL BL3 02 3/23/17 JLL BLDG FRAMING 3/23/17 DA March 23, 2017 9:58:17 AM jlierly. jeff 460-5147 March 23, 2017 4:44:31 PM jlierly. Inspection would be approved but the electrical permit was applied for today complete electrical process first before frame/jll BL3 03 4/17/17 JLL BLDG FRAMING 4/17/17 AP April 17, 2017 8:25:02 AM jlierly. April 17, 2017 8:26:01 AM jlierly. BL99 01 4/17/17 L BLDG FINAL April 17, 2017 8:26:29 AM jlierly. Jeff 460-5147 --------------- V—�N ------ ----------- COMMENTS AND NOTES -------------------------------------- CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT- BUILDING DIVISION 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Application Number . . . . . 16-00001504 Date 12/21/16 Application pin number . . . 454144 Property Address . . . . . . 3630 S AVIATION PL ASSESSOR PARCEL NUMBER: 06-30-07-1-1-0250-0000- REPORT SALES T" Application type description COMM NEW CONST on ur state excise tax form Subdivision Name . . . . . . yo Property Use . . . . . . . . to the City of Port Angeles Property Zoning . . . . . . . INDUSTRIAL HEAVY Application valuation . . . . 65000 (Location Code 0502) ---------------------------------------------------------------------------- Application desc Storage Building -------------------- Owner Contractor ------------------------------------------------------------------- Jeff Halsey OWNER 641 Sunset Heights PORT ANGELES WA 98363 (360) 460-5147 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT COMMERCIAL Additional desc . . STORAGE UNIT Permit Fee . . . . 775.25 Plan Check Fee 503.91 Issue Date . . . . 12/21/16 Valuation . . . . 65000 Expiration Date 6/19/17 V\ Qty Unit Charge Per Extension BASE FEE 670.25 15.00 7.0000 THOU BL-50,001-100K (7.00 PER K) 105.00 ---------------------------------------------------------------------------- Special Notes and Comments October 24, 2016 3:51:36 PM msanders. Fire Department access road must be maintained around the perimeter minimum 201 unobstructed width October 24, 2016 3:52:44 PM msanders. Occupancy Classified as S-1 December 19, 2016 4:05:18 PM pbarthol. Letter approving gravel parking approved per Craig Fulton. Parking wheel stops per approved plans. No land use problems anticipated. Electrical load calculations and electrical permits are required. Any modifications to the City's electrical facilities will be at the customer's expense. Construction to follow approved "Storm Drainage Plan" Contact Public Works Engineering Inspection Request number @ 360 417-4831 for the following inspections: 1. After erosion control BMP's are installed per plan and prior to the start of construction. 2. During installation of infiltration trench and piping, but prior to cover. 3. At completion of construction when site is stabilized and prior to occupancy. ----------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE SURCHARGE 4.50 Separate Permits are required forelectrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced, or if required inspections have not been requested within ISO days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder) T:Forms/Building Division/Building Permit BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS— Building Inspections 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION: Tootings Stemwall Foundation Drainage/Downspouts Piers Post Holes(Pole Bldgs.) PLUMBING: Under Floor/Slab Rough-In Water Line(Meter to Bldg) Gas Line Back Flow/Water AIR SEAL: Walls Ceiling FRAMING: Joists/Girders/Under Floor Shear Wall/Hold Downs Walls/Roof/Ceiling Drywall(interior Braced Panel Only) T-Bar INSULATION: Slab Wall/Floor/Ceili ng MECHANICAL: Heat Pump/Furnace FAU Ducts Rough-in Gas Line Wood Stove/Pellet/Chimney (�ommercial Hood/Ducts MANUFACTURED HOMES: Footing/Slab 1131ocking&Hold Downs ISkirting PLANNING DEPT. Separate Permit#s SEPA: Parking/Lighting ESA: -Ca—ndscaping ISHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY1 USE Inspection Type Date Accepted By Electrical 417-4735 Construction - R.W. PW /Engineering 417-4831 Fire 417-4653 Planning 417-4750 Building 417-4815 CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT- BUILDING DIVISION 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Page 2 Application Number . . . . . 16-00001504 Date 12/21/16 Application pin number . . . 454144 ---------------------------------------------------------------------------- REPORT SALES TAX .Fee summary Charged Paid Credited Due on your state excise tax form ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 775.25 775.25 .00 .00 to the City of Port Angeles Plan Check Total 503.91 503.91 .00 .00 Other Fee Total 4.50 4.50 .00 .00 (Location Code 0502) Grand Total 1283.66 1283.66 .00 .00 Separate Permits are required forelectrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced Within 180 days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder) T:Forms/Building Division/Building Permit BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS— Building Inspections 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION: T-00tings Stemwall Foundation Drainage/Downspouts Piers Post Holes(Pole Bldgs.) _KUMBING: Under Floor/Slab Rough-in Water Line(Meter to Bldg) Gas Line Back Flow/Water AIR SEAL: Walls Ceiling FRAMING: Joists/Girders/Under Floor Shear Wall/Hold Downs Walls/Roof/Ceiling Drywall(Interior Braced Panel Only) T-Bar INSULATION: Slab Wall/Floor/Ceiling MECHANICAL: Heat Pump/Furnace/FAU/Ducts Rough-in Gas Line Wood Stove/Pellet/Chimney Commercial Hood/Ducts MANUFACTURED HOMES: Footing/Slab Blocking&Hold Downs [Skirting PLANNING DEPT. Separate Permit#s SEPA: Parking/Light ESA: Landscaping ]SHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY1 USE Inspection Type Date Accepted By Electrical 417-4735 Construction - R.W. PW /Engineering 417-4831 Fire 417-4653 Planning 417-4750 Building 417-4815 CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT- BUILDING DIVISION C"T 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Application Number . . . . . 16-00001504 Date 12/21/16 Application pin number . . . 454144 Property Address . . . . . . 3630 S AVIATION PL ASSESSOR PARCEL NUMBER: 06-30-07-1-1-0250-0000- REPORT SALES TAX .Application type description COMM NEW CONST Subdivision Name . . . . . . on your state excise tax form Property Use . . . . . . . . to the City of Port Angeles Property Zoning . . . . . . . INDUSTRIAL HEAVY Application valuation . . . . 65000 (Location Code 0502) ----------- ---- - -----Application desc Storage Building ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ Jeff Halsey OWNER 641 Sunset Heights PORT ANGELES WA 98363 (360) 460-5147 ------P-e-r-mi--t---.--.--.--.--.--.---B-U-I-L-D-I-N-G--P-E-R-M-I-T-----C-0-MM--E-R-C-I-A-L---------------------- VIN Additional desc . . STORAGE UNIT Permit Fee . . . . 775.25 Plan Check Fee 503.91 Issue Date . . . . 12/21/16 Valuation . . . . 65000 Expiration Date 6/19/17 Qty Unit Charge Per Extension BASE FEE 670.25 15.00 7.0000 THOU BL-50,001-100K (7.00 PER K) 105.00 ---------------------------------------------------------------------------- Special Notes and Comments October 24, 2016 3:51:36 PM msanders. Fire Department access road must be maintained around the perimeter minimum 201 unobstructed width October 24, 2016 3:52:44 PM msanders. Occupancy Classified as S-1 December 19, 2016 4:05:18 PM pbarthol. Letter approving gravel parking approved per Craig Fulton. Parking wheel stops per approved plans. No land use problems anticipated. Electrical load calculations and electrical permits are required. - Any modifications to the City's electrical facilities will be at the customer's expense. Construction to follow approved "Storm Drainage Plan" Contact Public Works Engineering Inspection Request number @ 360 417-4831 for the following inspections: 1. After erosion control BMP's are installed per plan and prior to the start of construction. 2. During installation of infiltration trench and piping, but prior to cover. 3. At completion of construction when site is stabilized and prior to occupancy. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE SURCHARGE 4.50 Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced Within 180 days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced,or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulatin-9 construction or the performance of construction. Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder) T:Forms/Building Division/Building Permit BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS- Building Inspections 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION: T-00tings Sternwall Foundation Drainage/Downspouts Piers Tost Holes(Pole Bldgs.) PLUMBING: Under Floor/Slab Rough-In Water Line(Meter to Bldg) Gas Line Back Flow/Water TIR SEAL: Walls Ceiling FRAMING: Joists/Girders/Under Floor Shear Wall/Hold Downs Oalls/Roof/Ceiling Drywall(Interior Braced Panel Only) T--Bar INSULATION: '§-1a b Wall/Floor/Ceiling MECHANICAL: Heat Pump/Furnace FAU Ducts Rough-in Gas Line Wood Stove/Pellet/Chimney Commercial Hood/Ducts MANUFACTURED HOMES: Footing/Slab Blocking&Hold Downs ISkirting PLANNING DEPT. Separate Permit#s SEPA: Parking/Light ESA: Landscaping ISHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY1 USE Inspection Type Date Accepted By Electrical 417-4735 Construction - R.W. PW /Engineering 417-4831 Fire 417-4653 Planning 417-4750 Building 417-4815 CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY& ECONOMIC DEVELOPMENT- BUILDrNG DIVISION 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Page 2 Application Number . . . . . 16-00001504 Date 12/21/16 Application pin number . . . 454144 REPORT SALES TAX -7-------------------------------------------------------------------------- on your state excise tax form Fee summary Charged Paid Credited . Due - ----------------- ---------- ---------- ---------- ---------- to the City of Port Angeles Permit Fee Total 775.25 775.25 .00 .00 (Location Code 0502 Plan Check Total 503.91 503.91 .00 .00 Other Fee Total 4.50 4.50 .00 .00 Grand Total 1283.66 1283.66 .00 .00 Separate Permits are required forelectrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within.180 days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the.same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder) T:Forms/Building Division/Building Permit BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDEA MINIMUM 24-HOUR NOTICE FOR INSPECTIONS— Building Inspections 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION: Tootings Sternwall Foundation Drainage Downspouts Piers Post Holes(Pole Bldgs.) -KUMBING: Under Floor/Slab Rough-In Water Line(Meter to Bldg) 'da-s Line Back Flow/Water XIR SEAL: Walls Ceiling FRAMING: Joists/Girders/Under Floor Shear Wall/Hold Downs Walls/Roof/Ceiling Drywall(Interior Braced Panel Only) T-Bar INSULATION: Slab Wall/Floor/Ceiling MECHANICAL: Heat Pump/Furnace FAU Ducts Rough-in Gas Line Wood Stove/Pellet Chimney Commercial Hood/Ducts MANUFACTURED HOMES: Footing/Slab Blocking&Hold Downs ISkirting PLANNING DEPT. Separate Permit#s SEPA: Parking/Lighting ESA: Landscaping ISHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY1 USE Inspection Type Date Accepted By Electrical 417-4735 Construction- R.W. PW I Engineering 417-4831 Fire 417-4653 .Planning 417-4750 Building 417-4815 THE For City Use CITY OF ...... ........ Permit# (4 Per A S H I G T 0 N U. S. I if', Date Received: 3 2 1 E 5th Street Date Approved Port Angeles,WA 9836 FILM-= 1 %V P:360-417-4817 F:360-417-4711 Email:permits(@ci1yofpa.us 41T PPL BUILDING PERMIT PPLICATION Project Address: hone: '3 60- jyj�o-57 7 PrimaryContact: 3630 S Aho' -Votl P4 �Email: Jef�rh 6 1..tC'L 5 14 ifi*f.co M Name Phone Property Mailing Addres Email Owner S6'// sc.,A S"t- MC4,6-4y-5 City tVie. 'IV363 State JAIA z'p,,.3 t 3 Name M"L ko sr'-_44 Phone Contractor Address Email StSo C-I cvw,no k 160 Information city CAJ,.. W - State z'P7,200 IContractor License# Exp.Date: Legal Description:6-0 Vf" Zoning: � Tax Parcel# Project Value: (materials and labor) LOT' r V 7 5-P7O Ek.4 Pln & � - H 063007110S5-0000 s 4 Residential Commercial N Industrial 11 Public Permit Demolition Fire 11 Repair Reroof(tear off/lay over) 11 Classification For the following, fill out both pages of permit application: (check New Construction 0 Exterior Remodel 1:1 Addition 1:1 Tenant improvement appropriate) Mechanical 11 Plumbing El Other 11 Fire Sprinkler System Proposed Tfiri-gation System Proposed or Proposed Bathro Proposed Bedrooms or Existing? Yes 0 No PL I Existing? Yes 13 No IX 1 6 tj 0 In addition to standard hard copy submittals please send a PDF copy of all Stormwater plans and Engineering to www.stormwaterocityofpa.us Project Description 3o X i Yo Is project in a Flood Zone: Yes 13 No9L Flood Zone Type: .If in a Flood Zone,what is the value of the structure before proposed improvement? $ I have read and completed the application and know it to be true and correct. I am authorized to apply for this permit and understand that it is my responsibility to determine what permits are required and to obtain permits prior to work. I understand that plan review fees are not refundable after review has occurred. I understand that I will forfeit review fees if I withdraw the application before the permit is issued. I understand that if the permit is not picked up/issued within i8o days of submittal,the application will be considered abandoned and the fees will be forfeited. Datet7 _ 00-/6 PrintNameJf-fr 14A;154�y Signature _J Residential Structures Existing Proposed Construction For Office Use Area Descriptions(SQ FT) Floor area Floor area $Value new area Basement First Floor Second Floor Covered Deck/Porch/Entry Deck(over 30"or 2"d floor) Garage Carport Other(describe) Area Totals Commercial Structures Area Descriptions(SQ FT) Existing Proposed Construction For Office Use Floor area Floor area $Value new area Existing Structure (s) Proposed Addition 3:700 111'e )-) 4— Tenant Improvement? Other work(describe) Site Area Totals Lot/Site Coverage Calculations Lot Size (sq ft) ot Coverage(sq ft)foot print of %Lot Coverage (Total lot cov-- lot size) M VIdg Height I G 1,1 jr.3 I all structures 16220 sqft I I*'e� I a Site Coverage (Sq Ft of all impervious) %of Site Coverage(total site cov-- lot size) Mechanical Fixtures Indicate how many of each type of fixture to be installed or relocated as part of this project. Air Handler Size: # Haz/Non-Haz Piping Outlets: Appliance Exhaust Fan # Heater(Suspended,Floor,Recessed wall) # Boiler/Compressor Size: # Heating/Cooling appliance # repair/alteration Evaporative Cooler(attached,not # Pellet Stove/Wood-burning/Gas # portable) Fireplace/Gas Stove/Gas Cook Stove/Misc. Fuel Gas Piping #of Outlets: Ventilation Fan,single duct # Furnace/Heat Pump/ Size: # Ventilation System # Forced Air Unit I I I Plumbing Fixtures Indicate how many of each tVVe of fixtu e to be installed or relocated Plumbing Traps # Water Heater # Plumbing Vent piping # Medical gas piping #of Outlets: Water Line # Fuel gas piping #of Outlets: Sewer Line # Industrial waste pretreatment interceptor(Grease Trap) Size other(describe): T:\Forms\2015 CED Form Updates\Building&Permitting\BP\Building Permit 20150415.docx RT N- GELES WASHINGT. 0 N, U. S. A. Public Works & Utilities Department , December 8, 2016 Fawn and Jeff Halsey Admirals No rthwestSto rage. 3626 S.Aviation Way Port Angeles,WA 98863 Re: Building Permit No. 16-1504 Dear Mr.& Mrs. Halsey: The subject building permit is for a new 30'x 130' mini storage bUilding.,The,permit requires the addition of a hard surface for required-parking spaces.. You recently�u.brnitted a request for an exception to the permit requirements which.will allow you to use graivel,rather than a hard'surfalce to acco m-plish the parking spaces for this.new'mini storage building., I understand.that all of the parking currently available at your facilit ..y is also,gravel-. Therefore,your.request for an exception tothe hard surface parking requirement is approved. Congratulations on the addition to,your facility..and best wishes for your continued success. Please feel free.to contact meat 417-4800 or cfuIt6n@citVofpa.us if I can be of further assistance. Sincerely, Craig Fulton, P.E. Director of Public Works& Utilities, Phone:360-417-4800 Fax: 360-417-4542 Website:www.city6fpa.us Email: publicworks@Pcityofpa.us 321 East Fi,fth Street Port Angeles, WA 98362-0217 To the director of public works and utilities I am seeking an exception to the hard surface pavement. For parking I have lot parking stall plus at mini storage every renter has their own park space in front of their unit. Please see site map and pictures. Thanks you, sincerely Fawn and Jeff Halsey Admirals Northwest Storage C'60- S "pn4 ^ InAk� reiKosk We vt t_ UA C a�t 1 J` b'(d'I- bid) . �'5 ?n0j, S- f c-v-- (11 V E DEC 02 2016 1 L) J' CI ITUF15 F-ANr'52--Lr:IQ �V COMMUNITY&ECONOMIC DEVELOPMENT 44-C LAAArl�'�Aeli V I jt4k 1A, lb �N a'v—2—g—,26-1-6-5�:1,-1,:5,-7—P-M_P ST File Commands Help --------------NJ ECTOR 6"tuAa (3) a 'k T L ApprieWon number,ftc 16 00001504 COMM NEW CONST PruperlyaddMS: 3630 S AWATION PL November 28, 2016 4:47:06 PH abrekke. Per Section 14.40.140 of the PAMC, before the granting of a V6 building permit, proof of the existence of off street paxkxng spaces must be demonstrated. A site plan showing such off-street parking must be sul—Itted. Storage buildings require one parking space for each two employees with a minimum of ten parking -spaces. Because the property is zoned as Heavy Industrial, a request can be made to the Director of Public Works and Utilities to request an exception to hard-surface pavement requirements of Section 14.40.120 provided that adverse impacets to stormwater drainage, surrounding properties and public infrastructure are mitigated to the extent the Director deems re,sannably necessary and appropriate. Wheel stops would have to be added at an minimum. November 28, 2016 5:11:53 PH abrekke. rA I�jtA P j qboo L 7!j, j.41 61 vY 7TO&_A'1 .......... 14 Y W44fif-1 T'[VA1 .IP �ur OfA3 ' ID 3 Pa- e-5 .v ........... -r-r t,5� 1,loiAw651- 5'r"" Agm -5 6 Z4. 4 v A- Vo—1 -�1�402 1402 1402 1402 P ilit-c 1402 60 608 61 3618 3618 3626 3620 f t3630 ',,port Rc/ 4e iz 92 1929 '37251 1211/2016 Synacor Webmail WAI IMG-3479.JPG httpltwebmail.wavemaii.com/tVviewimages?id=4021 214 1211/2016 Synacor Wetxnail IMG-3478.JPG http:/Avebmail.wavemail.com,'tVviewimages?id=4021 34 12/l/2016 Synacor Webmail http�//webmail.wavemail.com/tVviewimages?id=4021 4/4 12/l/2016 Synacor Webmail Synacor Webmail bro(owavecable.com IMG-3481.JPG RLM -A IMG-3480.JPG http-./ANebmaiLWavemaii.com/tVviewimages?id=4021 1/4 )v f A0 G.C4L6 lAq '--4-4r r 0 t-arA 0 r31-4 Vol_7 5'�p 70 0 -01 '0 c.^-rr-'+ C,&ALtAm \d-4 I r OIL* T4 M F t: r 16j. 5�,TO, Al, 4rc. M vyull /0,1' "fir. VI- 014 1404t BMPIS C 105 Stabilized Construction Entrance Mo C 107 Stabilized Construction Road/Parking Area C-123 Plastic Covering C220 Storm Drain Inlet Protection Z0, ,044 W4 k X C-233 Silt Fence. .......... L Z�, T A r :7: OATe AL 77-,, 5rORNWATIE-k WE PL4N DATE: AWIRAL� AIV/ -5f"' 6- SONS SCALE 4o 3oyl3o srop-Aue auxi ENGINEERING, INC. (360) 452-3023 DRAWN BY. Z474AVIAT104WAI A' 619 S. Chase St., Port Angeles, WA 98362 CHECKED: SHEET OF EXHIBIT MAP FOR: ADMIRALS NORTHWEST STORAGE CLOSING CORNER FOUND 7" X 7" CONC. POST WITH J14" LEAD PLUG (5105114) GEOMPT#06JO0717 --- U,49 L-4 ,30' 94 OFFSET �OG C Lc) I F] M Z- 0 120 240 Q) SCALE IN FEET BA RN TO BE REMO VED C,3 PROPOSED Joxljo STORAGE LOT A BUIL01 G �LLJ c 6' 38956 ........... L L C IN SECTION 7, TOWNSHIP 30 NORTH, CURVE TABLE RANGE 6 WEST, W.M. CLALLAM COUNTY, WASHINGTQ.N CURVE RADIUS LENGTH DEL TA Cl 50.00' 89.18, 102*11'54 C2 50.00' 84.68' 97'02'J7" N.T.S. ci 20.00' 25.49' 73'00'50" F--E-Fxl C4 106.99' 221.81' 118*46'52" C5 439.9 7' 96.il 1 12'J234" �fl C6 439.9 7' 171.88' 22'2258" SEPTEMBER 2Z 2016 '(30N-6W) C7 20.00' 44.56' 127*38'58" C8 255.90' 40 11' 10',5c)'44- .0.U..2199 LAND SURVE)lNG 96382 MAPPING (80) a, 3 6 -2,6, DEVELOPMENT C0NSULjl:N:G:: t �AX 683-5310 EMEN# T -2161 CONSTRUC'nON MANAGEMENT '8W)681 SER#. 063007-WESWI401-092216 Residential and Lod ging Uses Residential dwelling units Two(2)parking spaces per dwelling unit Rooming and lodging uses One(1)parking space for each sleeping unit Nursing and convalescent homes,assisted living One(1)parking space for each three(3)beds facilities,adult family homes,group homes, sanitariums Public and Institutional Uses Libraries *One(1)parking space for each four hundred(400)feet of floor area Museums One(1)parking space for each three hundred(300)feet of floor area Schools: Junior Colleges and technical schools As determined by the Planning Commission Elementary schools One(1)parking spaces for each classroom Middle Schools three(3)parking space for each classroom Preschools Ten(10)parking spaces for each classroom Senior High Schools Six(6)parking spaces for each classroom Social clubs,lodges,fraternal organizations w/o One(1)parking space for each fifty(50)square feet of floor area of the building fixed seating Areas of assembly without fixed seating shall As determined by the Planning Commission provide seating Churches,stadiums,sports areas,and other such One(1)parking space for each three(3)fixed seats places of assembly with fixed seating Senior centers One(1)parking space for every one hundred thirty-five(13 5)square feet of floor area Industrial Uses Manufacturing uses One(1)parking space for each three(3)employees with a minimum of ten(10)spaces Trucking and transportation terminals Minimum of ten(10)spaces tWholesale stores,warehouses,storage buildings One(1)parking space for each two(2)employees with a minimum of ten(10)parking spaces Public and Quasi-Public Recreation Uses Parks and playgrounds As determined by the Planning Commission Public and private golf courses As determined by the Planning Commission Swimming pools Ten(10)parking spaces for each 1,000 square feet of pool surface area Unspecified Uses If a use is not otherwise specifically mentioned in this section,the requirements for off-street parking facilities shall be the same as the requirements for the most similar use listed herein as determined by the Director of the Department of Community Development. MUed Uses In the case of a mixture of uses on one lot or in one building,the total requirements for off-street parking facilities shall be the sum of the requirements for the various uses computed separately. Cooperative and Shared Parking Provisions Parking facilities may be cooperatively used by different land uses when the times of the uses are not simultaneous. Parking facilities may be shared when the times are not simultaneous through a parking agreement with the property owners and when the parking is located no further than 500 feet from the property requiring the parking. �P—A—RKING STALL DEVELOPMENT: Standard=8'6"X 18' Handicapped: 13'6"x 18' (Van) 166"x 18' Created 3/12/04;Amended: 11/20/2011 TAPARKrNG\Tab1eAfina1.wpd 11/20/2011 PARKING REQUIREMENT TABLE"A" LAND USE PARKING SPACE REQUIREMENT Automobile Services Automobile service and repair shops Three(3)parking spaces plus one(1)for each mechanical bay Automobile sales dealerships Two(2)per employee Gas stations with convenience stores One(1)parking space for each employee with a minimum of six(6)parking spaces. Drive aisles must accommodate two(2)cars per pump. Commercial A ctivilies Banks,professional and business offices One(1)parking space for each four hundred(400)square feet of floor area Bowling alleys Six(6)parking spaces for each alley Fumiture/appliance stores and laundries One(1)parking space for each six hundred(600)square feet of floor area Night clubs and lounges One(1)parking space for each fifth(50)square feet of floor area Retail stores One(1)parking space for each three hundred(300)square feet of floor area Skating rinks and other commercial recreational One(1)parking space for each two hundred(200)square feet of floor area places Theaters One(1)parking space for each three(3)seats Music,dance,art,and other academies Eight(8)parking spaces for each classroom Food Service Activities Food/grocery stores One(1)parking space for each three hundred(300)square feet of floor area Restaurants,tavems,and.any other One(1)parking space for each one hundred twenty-five(125)square feet of floor area of the establishments for the sale and consumption of building food,alcoholic beverages,or refreshments Food and beverage establishments that do not One(1)parking space for each employee and three(3)per drive-up window have on-site seating Personal Services Barber,beauty shops,tanning salons,physical Two(2)parking spaces per station(office area at one for each four hundred(400)square feet) therapy,and similar services Day care centers Two(2)parking spaces plus one(1)unloading space for those centers serving twelve(12)or fewer children;One(1)parking space per employee plus two(2)parking spaces for unloading for centers of more than twelve(12)children Medical Services Medical and dental offices Six(6)parking space per doctor. When licensed practitioners are working in the medical office along with the doctor(s),two(2)additional parking spaces are required for each independent practitioner/service provider. Hospitals As determined by the Planning Commission Research,dental,x-ray laboratories One(1)parking space for each two hundred(200)square feet of floor area 2 1402 C/? ................. all 71 IM7 'b6 300 308 312 302 3A6 41� 3609 608 612 18 co W 3626 �v_ IAO 3620 320 I'll's 3630 304 b.,j 0 0 RC, _1� �a 316 'On qj ic 41 306 316 318,11,S 110 Ll 1929 '7,9 31 �721 1935 320 31 14 316 318 318 At -�., �� 3 3213 322 0 R- T NGELES A. � V A S H I N G T 0 N, U. S. A. 040WA COMMUNITY & ECONOMIC DEVELOPMENT DEPARTMENT DATE: October 20, 2016 TO: Jeff Halsey 641 Sunset Heights Port Angeles, WA 98363 FROM: Jim Lierly; Community & Economic Development, Building Dept. SUBJECT: Storage Building Plan review. Mr. Halsey, the comments below will need to be addressed to complete you review for the building permit application you have submitted. 1 . The Seismic design for our area is D2 please verify with your Engineer that this was the design category used in the Engineering calculations. 2. If there will be any interior walls (storage partitions and or hallways etc. Provide a floor plan per code that details such a plan that includes location, type of material used and any exit path or access way to the exterior. Also verify roof classification per code. 3. Provide wall details and sections for rated assemblies separating the units if interior partitions are applicable. 4. Will there be any condition space in your project envelope? If this is applicable, please provide any energy calculations Per 2015 WSEC. 5. Please provide Lighting calculations per 2015 WSEC. Also if there are any interior exit routes please include emergency lighting and exit signs if applicable per code. 6. 3 RD party special inspections shall be required for concrete & reinforcement, any welding and or high strength bolting per Chapter 17 of the 2015 IBC. 7. Electrical permits shall be submitted separately through Public works. These items will need to be addresses before any submittals may be approved. These review comments are for the City of Port Angeles Building Dept. only. Other comments or requirements may still be pending review or corrections response from other departments before issuance of your submittal may occur. All work performed in the field, shall be subject to inspection approval. Regardless of what is on the plans. Items on plans do not always reflect construction issues that arise in the field. If you have any questions please feel free to contact me. Jim Lierly City of Port Angeles Building Inspector Plan Review Code Enforcement 360-808-0534 jlierly@cityofpa.us 50W LED Floodlight, Outdoor LED Flood lights LER Page I of 6 New user enjoys extra 8%off coupor, I Sign in or Register My Account Support Center Cart(O Item) I How to buy Trade i CNI w for ftft LIGHTING I iSearch products Go LEEVER ....................------------------- Free Shipping On Orders Over$50.00 In US PRODUCTS APPLICATIONS PROMOTION LIGHTING IDEAS ABOUT US Horne LED Flood Light LED Floodlights SOW LED Flood Lights,37501m,Daylight White,15OW HPS Bulbs Equiv,Super Bright Stadium Light, SOW LED Flood Lights, 37501m, Daylight White, I SOW HIPS Bulbs Equiv, Super Bright Stadium Light, Outdoor LED Security Lights N 18 Review(s)1 4 answered question(s) --------------- (Price4 87 q 0) Special Price Save $39.99 You $47.51(S4%) ............ ..................... Light Color,. Warm WM, ..... ........ . ......................... 240W Wattage: I OW 20W i 3OW 5OW W 1"" '__ ILEO �w J ]so Status: Over 50 units In stock, QTY: F77 Add to Cart Add to Wishlist ....................... Free Shipping Over$50.00 30 Days Money Back 2 Years Warranty i Certification �Vj .......................... .................. .............. .................................... ............ .......... Share: Specifications Reviews(I 8) Q&AW) Downloads SKU 3400029-DW Lamp current(mA) 1500 Switching Cycles 25,DOO Rated lifetime(h) 50,000 Wattage(W) 50 Brightness(Im) 37SO HIPS Equivalent(W) is( LED Quantity Light Color Da�lightWhite Color Temperature(K) 6000 Dimmable Non-dimmable CRI >70 Beam Angle(Degree) 12C Input Voltage(v) 100-240 AC Frequency(hz) SO-60 Power Factor -'0.9 Length(in) ll.?2 Width(in) 10.83 Height(in) 2.73 Material Glass,Aluminu m Power Srouce AC Shock Proof Yes Waterproof Yes. Protection Rating IP66 Applications Garage Lighting,Garden Certification IS090012008,CE,C- Package Quantity Pac,of I Unit Warranty 2 Years Download IES for lightirg design http://www.lightingever.com/50w-super-bright-led-flood-lights-dw.html 11/4/2016 50W LED Floodlight, Outdoor LED Flood lights I LE9 Page 2 of 6 Applications Ideal for outdoor gardens,wall lighting,yards,lawns,indoor warehouse, workshops,etc L=_J Product Description Sufficient Brightness -Its brightness is up to 3750 lumen�3250 lumen,fully meets your lighting needs, -No shadow,dizzy light,providing you excellent bright light, Energy Efficient -More energy efficient than old halogen lamp,great replacement for 15OW HPSL(high pressure sodium lamp),saving over 65%on your electricity bill. Wide Beam Angle -120*beam angle,providing you with wide illumination range. Usage Recommendation -General lighting:illumination area is 30-50 sq.m.with about 75-150 lux when installation height is 5-7 meters. -Outdoor light:illumination area is 50-70 sq.m.with about SO-75 lux when installation height is 6-8 meters. Durable -With fully aluminum alloy Die-casting case,this flood light has excellent heat dissipation,which effectively prolongs its litespan. -By adopting tempered glass,the panel is much more durable. Flexible Installation -it comes with a metal bracket on the lamp body,allowing you to install the light flexibly,including ceiling-mounted,wall- mounted,and ground-mounted. -The lamp body can be adjusted 150-,flexible enough to meet your lighting requirements. Versatile -With IP66 rating,this floodlight can be widely used in outdoor lighting projects as billboards,show windows,gardens,patio, court,lawn,etc. -You can also use it in your warehouse,workshop and use it as security lighting, Key Data Wattage: 50W Luminous flux:3750 lumen/3250 lumen Light color:Daylight white/Warm white IP rating:IP66 Material:Aluminum Tempered Glass+Iron Dimension:285*275*70mrn Leading wire:30 cm(plug not provided) More Recommendation: I if you plan another lighting project in your home or commercial places,you can also find other LE flood lighting products in our store.A variety of wattages,colors and other configurable functions(motion sensor,remote controlling,solar powered, plug in,rechargeable,portable,etc.)are all available! How to Install 50W LED Floodlight I Drill mounting holes according to the screw bits in the lamp bracket. 2 Attach the barcket and screw on to make it into position. 3-Adjust the lighting direction as you like. 4-Connect the power lead to mains supply. http://www.lightingever.com/50w-super-bright-led-flood-lights-dw.html 11/4/2016 SUPERIORLIGHTING.COM W"M hi ha as an I ergv saviong 1:3 a LED Outdoor Flood Light Fixtures The LED Outdoor Flood Lights are efficient, energy saving replacements for metal halide and halogen fixtures. The outdoor fixture can mount at a broad range of angles. LED outdoor flood light fixtures are ideal for wet locations. Perfect for up or down lightng, for wall washing, flagpole, landscape, security, driveway spotlight or area floodlighting. Perfect for commercial & residential use FEATURES: • Replaces 100 waft halogen through 175 waft metal halide fixtures • Compatible with mechanical relay type Photocell & occupancy sensor • 50,000 hours of maintenance-free operation to L70 at 15 degrees C •Tempered glass lens, thermal shock and impact resistant • Constructed without any hazardous materials • Die-cast aluminum housing and lens frame • Universal 120 to 277V, 50/60 Hz driver • LED Daylight at 5,600K • Silver powder-coat finish • 3-year warranty CONSTRUCTION: 1-800-545-7778 - Cooper plating provides high thermal transfer rate, minimizing the juntion temperature of the LEDs. - Heavy duty cast aluminum twopiece housing is polyester TGIC powerder-coated for long durability, rust and corrosion resistant and IP65-rated to seal out water, dust and insects DETAILS: 650 3 4""'X"35""' 'r�7'80.10GALOII 20 7801CGAL014-50K 2,000 65 50,000 7" x 5.T x 3.9?' 7-`�,,F'7,1, '47,27,�k�5 7$q..I�CGAL030-60, 00"', X"' '_mw 50 7801 CGAL050-50K 3,700 1 65 50,000 11.4" x 9.25" x 5.9" Superior Lighting: 1-800-545-7778 1 Web:www.superiorlighting.com Email:sales@supedodighting.com I Fax: 954-735-7592 . rImA No S T E E L 5650 El Camino Real, Suite 100, Carlsbad, CA 92008 Phone: (760) 448-1760 Fax: (760) 448-1761 October 21, 2016 Jim Lierly City of Port Angeles Building Inspector, Plan Review, Code Enforcement 360-808-0534 jlierly@cityofpa.us Jeff Halsey Admiral Storage 641 Sunset Heights Port Angeles,WA 98363 The following is a partial response to plan review comments dated October 20, 2016. Responses are indicated in Bold type. All remaining items to be addressed by others. 1. The Seismic design for our area is D2 please verify with your Engineer that this was the design category used in the Engineering calculations. Response: Per the 2012 IBC for commercial structures, calculations were made for site class D and design category D. 2. If there will be any interior walls (storage partitions and or hallways etc. Provide�i floor plan per code that details such a plan that includes location, type of material used and any exit path or access way to the exterior. Also verify roof classification per code. Response: The Partition Plan on sheet S2.1 is the floor plan for the building. Materials used for all walls are called out on this plan.All units are accessed from roll-up doors on the exterior of the building.The standing seam roof is comprised of 24ga steel panels and is classified as Class A.A note has been added to detail 18/SDI stating a Class A roof. 3. Provide wall details and sections for rated assemblies separating the units if interior partitions are applicable. Response: The building is occupancy S-1 and construction type 2B. Since the building is under 12,000 square feet, per 2012 IBC Table 503 and section 903.2.9,there is no requirement for any rated assemblies or fire sprinkler system. 6. 3RD party special inspections shall be required for concrete& reinforcement, any welding and or high strength bolting per Chapter 17 of the 2015 IBC. Response: Concrete notes on sheet S1.1 have been revised to state 3,000psi concrete which will require special inspection.Also, Hilti KB-TZ anchors will require periodic special inspection. Special Inspection notes have been added to sheet SIA. Please call me with any questions or comments. Thank you, L I? Michael Michael R. Dale, PE 'a e Project Engineer Digitally signed by M.ichael Dale DN:c=U ,o=U5,.Governnnent, 4;� ou=ECA,'.Gu=VeriSign,Inc., 40700 ou=Una'ffi' liated,cn–Michael GISTV- Da'0' 6a—te:2016.1011 11-05:59-07-00- L ENFIRES: 05-18]:7] MAKO Steel , Inc . SELF STORAGE BOAT STORAGE RV STORAGE V_L I? 1463 . .6 Whael August 2016 R. D5.a I e Digitallysig ",hed lo�)Michael Dale DN:c=US,,p=U.S.G6�wnment­, ou=EC�,Su=Vle-risign, 4Q cA) ou=Unaffiliated,cn=Michael M 40700 Da S T B 'e 2016.08.16 15:36:53-07'00' Transverse FERPIRES: 05-1-8-171 PartiLlUl I=I IU Shear Walls Moveable vmg- Longitudinal Partitions M. 5 K-S -Ell -5, Purlin c re Prepainted A 26GA Trim Galvalume 26GA Multi-Rib Roof Panels :4 1 110.�1, L Support Columns 4 Metal Piers 4 f Prepainted Prepainted 11 Roll-Up Doors 26GA Multi-Rib Wall Panels Structural Calculations for Admiral Storage Port Angeles, WA Sheet Index 1. Design Loads 2 2. Vertical Analysis—Roof Panet,Purlin,&Beams 4 3. Exterior Wall Analysis—Exterior Siding&Posts 18 4. Lateral Analysis 28 5. Shear wall table 34 Page 1 CARLSBAD,CA 92008 Ph:(800)383-4932 Fax:(760)448-1761 MAKO Steel, Inc.I MAKO Structures, Inc. 5650 El Camino Real, #100 Carlsbad, California 92008 Phone: (760)448-1761 Fax: (760) 448-1761 STRUCTURAL CALCULATIONS FOR ADMIRAL STORAGE: 3626 SOUTH AVIATION PL; JOB NO.: 1463 PORTANGELES,WA DESIGN CODES: ASCE 7-10 2012 INTERNATIONAL BUILDING CODE AISI COLD FORMED STEEL DESIGN MANUAL 2010 EDITION AISC STEEL CONSTRUCTION MANUAL(ASD) 13th EDITION MATHCAD DEFINED UNITS ARE..... IN =- lL LB =- 1M FT=- 12-IN Sl -- IN 2 SF =- FT2 Cl =- IN 3 KIPS 1000-LB PSF=- LB PLIF =- LB PSI =- LB KSI =- 1000-LB PCF=- LB E =- 29500-KSI FT 2 FT IN 2 Sl FT 3 DESIGN LOADS: S:= 25-PSF ROOF SNOW LOAD D,:= 4.0-PSF ROOF DEAD LOAD, DECK 1.1-psf, 0.5-PSF Insulation, 1.0-psf elect/mech/misc, co-lat 1.0-PSF WIND 126 MPH EXPOSURE 'C', NEARLY FLAT ROOF, ENCLOSED, SIMPLIFIED METHOD X:= 1.21 ADJ. FACTOR FOR 15 FT EAVE HT&EXP. RISK CATEGORY 11 FIND MAIN WINDFORCE-RESISTING SYSTEM PRESSURES Ps30.A:= 25.20-PSF Ps.A:= X-Ps30.A= 30.49-PSF HORIZONTAL AREA A PS30.C:= 16.72-PSF PS.0 X-Ps30.0= 20,23-PSF HORIZONTAL AREA C,MIN 16-PSF P130.G := 21.08-PSF PS.G X-PS30.G = 25.51-PSF VERTICAL AREA G FIND COMPONENTS AND CLADDING PRESSURES, EFFECTIVE AREAS Pnet30.1 26-92-PSF Pnet.1 X-Pnet30.1 = 32.57-PSF ROOF UPLIFT ZONE I PURLIN,50-PSF Pnet30.2 36-12-PSF Pnet.2 X'Pnet3O.2 = 43.71-PSF ROOF UPLIFT ZONE 2 PURLIN,50-PSF Pnet30.1b 28.60-PSF Pnet.1b X'Pnet30.1b= 34.61-PSF ROOF UPLIFT ZONE 1 PANEL,I O-PSF Pnet30.2b 48.00-PSF Pnet.2b X-Pnet30.2b= 58.08-PSF ROOF UPLIFT ZONE 2 PANEL,1 O-PSF Pnet30.3b 72.24-PSF Pnet.3b X"Pnet30.3b= 87.41-PSF ROOF UPLIFT ZONE 3 PANEL,10-PSF Page 2 Pnet30.4 28.04-PSF Pnet.4:� �"Pnet:30.4 � 33.93-PSF HORIZONTAL ZONE 4 POSTS,50-PSF Pn.t30.5 32-30-PSF Pnet.5:= X'Pnet3O.5 = 39.08-PSF HORIZONTAL ZONE 5 POSTS,50-PSF Pnet30.4b:= 31.04-PSF PnetAb X'Pnet30.4b= 37.56-PSF HORIZONTAL ZONE 4 PANEL,1 O-PSF Pnet3O.5b:= 38.30-PSF Pnet.5b X'Pnet30.5b= 46.34-PSF HORIZONTAL ZONE 5 PANEL,1 O-PSF SEISMIC SITE CLASS"U'PER SOILS REPORT SEISMIC SYSTEMA.13: PER SOIL'S REPORT I := 1.0 IMPORTANCE FACTOR PER TABLE 11.5-1 (CATEGORY 11) R:= 6.5 RESPONSE MODIFICATION COEFF Qo:= 3 OVERSTRENGTH Cd := 4 DEF AMP. SS:= 1.588 S, := 0.643 MAX.GROUND MOTIONS 0.2&1.0 SEC.SITE CLASS E(ONLINE SOURCE) F, := 1.00 F,:= 1.50 SITE COEFFICIENTs(TABLEs 11.4-1, 11.4-2 SITE CLASS E 2 SMS:= F,-SS-I 1.588 SDS := -'SMS= 1.059 3 2 SM, := F,.Sl 1 0.964 SD1 := --SM, = 0.643 3 SDS DESIGN CAT.D P:= 1.3 REDUNDANCY FACTOR Cs:= - = 0.163 R Qe := Cs= 0.163 (LFMSW) MATERIAL SPECIFICATIONS: COLD-FORMED STEEL....ASTM A653 GRADE 55 FOR 14GA&12GA CEE MEMBER ASTM A792 GRADE 80 FOR ROOF DECK STRUCTURAL STEEL......ASTM A36 BASE PLATES ASTM A500 GRADE 46 COLUMNS BOLTS............................ASTM A325 USED IN SHEAR ONLY FOR BEAM TO COLUMN CONNECTION ASTM A307 USED FOR PURLIN TO BEAM CONNECTION SCREWS.........................ALLOWABLES PER 2007 AISI TABLES & MANUF TESTED DATA HILTI SCREWS SOIL...............................ALLOWABLE SOIL BEARING= 1,500-PSF PER CHAPTER 18 OF THE 2012 IBC CONCRETE.....................FOUNDATION&TILT BY OTHERS REBAR............................BY OTHERS ALLOWABLE STRESS DESIGN DEFLECTION& DRIFT LIMITS APPLICABLE BASIC LOAD COMBINATIONS (ASCE 2.4.1) VERTICAL PER IBC TABLE 1604.3 2. D+ L HORIZONTAL WIND PER AISI 360 L4. 3. D+ (Lr or SNOW) HORIZONTAL SEISMIC PER ASCE TAB. 12.12-1 4. D+ .75L + .75(Lr or SNOW) 5. D+ (0.6W or.7E) 6. D+ .75(0.6W or.7E)+ .75 L + .75(Lr or S) 7. .6D+ 0.6W 8. .6D+ .7E Page 3 ROOFDECK: USE 24 GA. McELROY"MIRAGE" PER MANUR TABLE THE SECTION PROPERTIES ARE... DECKING: ASTMA792 GRADE "50A" ORASTM A653 GRADE 50 CLASS I F – 50.KSI = 50-KSI yp S,p:= 0.0998-Cl POSITIVE S,,,:= 0.0797-Cl NEGATIVE 1,,p:= 0.1250-IN 4 POSITIVE 1,,,:= 0.0710-IN 4 NEGATIVE MAXIMUM DECK SPAN OF Lds := 5.00-FT FIND GRAVITY LOAD BENDING MOMENTS AND STRESSES @ SPAN& CANTILEVER W:= (1.39.PSF+ S)-FT= 26.39-PLF UNIFORM LOAD w-Lds 2 1 Mds := — = 0.792-IN-KIPS fbdl:= Mds'— = 7.933-KSI 10 Sxp THE ALLOWABLE BENDING STRESS PER AISI SEC. V.A.3.3.2 Fbpanel:= 0.6,Fyp= 30-KSI OK> SPAN OR CANTILEVER STRESSES CHECK DEFLECTION: w-Lds 4 Lds Ad, := 0.0069 – -.053-IN — = 1125 OK> 180 E-Ixp Ads FIND WIND LOAD BENDING MOMENTS AND STRESSES @ SPAN& CANTILEVER Ww:= F(O-6-Pnet.3b)– 0.6(l.39-PSF)]-FT= 51.612-PLF UNIFORM LOAD Ww-Lds 2 1 Muds:= — N-KIPS fbuds:= Muds— = 15.515-KSI 10 sxp THE ALLOWABLE BENDING STRESS IS... Fbpanel2 :� 0.6,Fyp= 30-KSI OK > SPAN OR CANTILEVER STRESSES CHECK DEFLECTION: Ww-Lds 4 Lds A,d,:= 0.0069.— = 0.104-IN OK> 180 E-Ixp Auds CAECK ROOF PANEL CONNECTION: DETERMINE REQUIRED SCREW SPACING FOR WIND UPLIFT. PANEL WILL BE SCREWED DIRECTLY TO 16 GAUGE ROOF PURLINS, EAVE TRACKS,AND RAKE ANGLES. THE ALLOWABLE PULLOUT FOR #10 SMS INTO 16 GAUGE MATERIALIS 145 LBS * 1.44 = 208 LBS. THE ALLOWABLE PULLOVER FOR #10 SMS THROUGH 22 GA MATERIAL IS = 246 LBS * 1.44= 354 LBS. DESIGN PULLOUT FORCE IS..... Tl := (0-6-Pnet.2b)-Lds-16-IN= 0.232-KIPS REQUIRED TENSION IN ZONE 2 T2 := (0-6-Pnet.3b)-Lds-16-IN= 0.35-KIpS REQUIRED TENSION IN ZONE 3 T,, := 2-0.208-KIPS = 0.416-KIPS ALLOWABLE TENSION THEREFORE, USE A 26 GAMIRAGE ROOFPANEL WITH AMIN 22 ROOF CLIPSWITH(2)#10 SCREWS TO EACH PURLIN,EAVE CHANNEL,AND RAKE ANGLE. Page 4 5 . 7 `J V, "E.ILK-11")Y, I AfiQhA,,r_^. 0-0, jct� go i�s LA 4,7, 2 Issue Date January 22,2007 No. 07-285-07 Mirage (Bare Galvalume& Pairited Galvalume) 5. 8. ------- --- _16" COVERAGI- )P IN COMPRESSION- BOTTOM IN COMPRESSION GAUGE WEIGHT I S� Ma - e Ma SF) 4/ft.) .3/ft. kip-in. 4/ft .3 kip-in./ft. KSI (P (in (in /ft. (in.1 (iiri 24 7 50.0 1 1.38 1 1.4390-1 01250 1 0.09998 1 2.9-870 0,0710 O�0797 2.3290 1.Section properties are calculated with the 2001 AlSl North American 4.Se is for bending. Specification for the Design of Cold-Formed Steel Structural Members. 5.Ma is the allowable bending moment. 2.Va is the allowable shear. 6.All values are for one foot of panel width. 3.Ix is for deflection determination. Allowable Uniform Loads (PSF) Span in Feet Span Type Load Type 1.00 1�50 2.00 2.50 300 4.60 500 6.b0 6.CQ 6 50 700 .7,50 6.00 8.50 Positive Wind 500 500 497 318 221 162 124 98 79 65 56 47 40 35 31 27 Single Live 500 500 497 318 221 162 124 98 79 65 55 47 40 35 31 27 Deflection(L/180) 500 500 500 500 404 254 170 119 87 65 50 39 31 25 21 17 Deflection(L1240) 500 500 500 500 1 303 191 128 89 65 49 37 29 23 19 16 1 13 1 I!ositive Wind 500 500 367 239 168 124 95 75 1 61 50 42 36 31 1 27 24 21 L 500 500 367 239 168 124 95 75 61 50 42 36 31 27 24 21 2 Span 501) 500 500 500 500 481 322 226 165 124 95 75 60 48 40 33 IDeflection(U240) 500 500 500 5DO 500 360 241 169 123 93 71 56 45 36 30 25 Positive Wind 500 500 449 295 1 208 154 118 94 76 63 53 45 39 34 30 26 3 Span Live 500 500 1 449 295 208 154 118 94 76 1 63 53 1 45 39 34 30 26 1 Deflection(l 500 500 500 500 500 377 1 252 177 129 97 74 58 47 38 31 26 Deflection(1 500 500 500 5DO 449 262 189 133 96 72 56 44 35 28 23 19 Positive Wind 500 500 422 27-7 194 144 111 88 71 59 49 42 36 32 28 24 4 Span 1 ve 500 600 422 277 194 144 ill 88 71 59 49 42 36 32 28 24 IDeffection(1_1`160) 1 500 500 500 5130 500 1 400 268 188 137 103 79 62 50 1 40 33 27 500 20 IDeffection(L/240) 1 500 500 1 500 1 476 1 300 201 1 141 1 102 77 1 59 1 46 37 30 t-21 - I ASTM El 592 Wind Uplift Testing Ite 37 1 34 1 31 1 28 1 25 1 22 1 20 in Notes: 1.Allowable uniform loads are based upon equal span lengths. 2.Positive Wind is wind pressure and is NOT increased by 33 1/3 3.Live is the allowable live or snow load. 4.Deflection(L/180)is the allowable load that limits the panel's deflection to U180 while under positive or live load. 5.Deflection(1-1240)is the allowable load that limits the panel's deflection to U240 while under positive or live load. 6.The weight of the panel has NOT been deducted from the allowable loads. 7.Positive wind and Live load values are limited to combined shear&bending using Eq.C3.3.1-1 of the AISI Specification. 8.Values of ASTM E1592 Wind Uplift Testing include a factor of safety of 2.0.Shaded areas are outside of test range.Contact McElroy Metal for more information. 9.Web crippling has NOT been checked for this panel. 10.Load Tables are limited to a maximum allowable load of 500 psf. ccipPoiii imp"Ff"IdE EPQ, st LA SOUTHEAST:PIVIStON..- PEACH.T"Riii��A WESTIERN�DJVISIOW A A00 NT�' �'-A NORTHUAST D)VIS[ON E9,VA SOUTHWEST DIVISION i 60S�"OtT'Y_�LA, SL,,O)E�$ AT LAI' WEOT TEYAS;IDIV1t.1ON MERKEL T-IX P,ri It MS01VE ION PURLIN DESIGN: SPRINKLER LOADS INCLUDED Llo:= 10.00-FT CHECK PURLIN SPAN Ld, = 5-FT PURLIN SPACING Wd := D,-Ld, = 20-PLF UNIFORM DEAD LOAD wr:= S-Ld, = 125-PLF UNIFORM ROOF SNOW LOAD LOw:= Pnet.2,Lds = 219-PLF UNIFORM WIND UPLIFT LOAD Mlo:= 13.920-KIPS-IN MAXIMUM MOMENT AT CENTER SPAN OF 'Z'4"xl6GA, PER CFS OUTPUT MlOS := 17.400-KIPS-IN MAXIMUM MOMENT SPLICE, PER CFS OUTPUT USE 'Z'4"x2 1/2"xl6 GAGE PURLINS AT 10'-0" SPAN, TYP, PER CFS OUTPUT CHECK DEFLECTION: Lio Alo:= 0.38-IN — = 316 OK Alo DESIGN CONTINUITY SPLICE TYPICAL: V,:= 0.430-KIPS ALLOWABLE SHEAR FOR#12 SCREW INTO 16GA MATERIAL Nl := 3 NUMBER OF SCREWS FOR CONNECTION M,:= V,.N,-18.IN = 23.22-IN-KIPS ALLOWABLE MOMENT mlos — = 0.75 < 1.00 OK USE (3)#12 TEKS 18"A PART-WORSE CASE 10'SPANS M, POST DESIGN: Pl := 1.600-KIPS REQUIREDAXIAL LOAD USE 'C4"x2 1/2"xl8 GA, Fy= 55KSI H < 10'-0" SEE CFS OUTPUT FOR CALCS THE WEB OF THE POST WILL BE ATTACHED TO THE WEB OF THE PURLIN WITH SCREWS. ONE FLANGE OF THE POST WILL BE ATTACHED TO THE SHEAR WALLIPARTITION PANELS WITH SCREWS. POST TO PURLI N CONNECTION DESIGN: V,3:= 0.308-KIPS ALLOWABLE SHEAR FOR#12 SCREW INTO 18GA MATERIAL N3 := 6 USE (6)#12 TEKS Pa := Va3-N3 = 1.848-KIPS P, = 0.87 < 1.0 OK Pa Pup:= [(0.6'Pn.1.2) – 0.6.(1.39-PSF)]-(Ld,*Llo) = 1.269-KIPS SHEAR DUE TO WIND UPLIFT PUP 0.69 < 1.0 OK Pa Page 6 CFS Version 9.0.4 Page 1 Analysis: Analysis 25-126-5xlO.cfsa 3-Span Continuous Beam Rev. Date: 8/16/2016 ROOF PURLINS, TYP Printed: 8/16/2016 Member Check - 2010 North American Specification - US (ASD) I il 11 1 111 1 111111 111111 1111 1 111111 111111 1111 1 111111 111111 1111 1 11 111111 Load Combination: D+S Design Parameters at 10.000 ft, Right side: VX* 1-6.,*0 o b �'-6 t Ly 2.764 ft Lt 2.764 ft -66 6 b Ky 1.0000 Kt 1.0000 .S e c t ion:-4 Z I&.�c f s s Material'T�pe: A6107 Class 2 Grade 55, Fy=55 ksi Cbx 1.6667 Cby 1.0000 ex 0.0000 in CmX 1.0000 Cmy 1.0000 ey 0.0000 in Braced Flange; Top k� 0 k Red. Factor, R: 0.7 Lm 10.000 ft Loads: P MX Vy My VX (k) (k-in) (k) (k-in) (k) Total 0.0000 -17.400 0.7250 0.000 0.0000 Applied 0.0000 -17.400 � 0.7250 0.000 0.0000 Strength 6.5692 19.286 3.8424 11. 908 4 .5963 Effective section properties at applied loads: Ae 0.58626 in^2 Ixe 1.5446 in^4 Iye 1.0793 in^4 Sxe(t) 0.75363 in^3 Sye(l) 0.37827 in^3 Sxe(b) 0.79194 in^3 Sye(r) 0.39122 in^3 -qu4_'Tpns NAS E,q-'..,,.C5,' 2.=L1, M�'*'.My): "My'), 0 6 5 WAS; 7C Maximum Shears, Moments, and Deflections --UUU---UU-J--UUU---LLJU---UU-J--ULL---UUU---UUA--UUU---LJUU---ULJ-�--L--UUU-- Load Combination: D+S, Y Direction Location Shear(l) Shear(r) Reaction (ft) (k) (k) (k) 0.000 0.0000 0.5800 0.5800 10.000 -0.8700 0.7250 1.5950 20.000 -0.7250 0.8700 1.5950 30.000 -0.5800 0.0000 0.5800 Location Moment Location Deflection Inflections (ft) (k-in) (ft) (in) (ft) 4.000 13.920 4.460 -0.37855 8.000 10.000 -17.400 11.127 0.02291 12.764 15.000 4 .350 15.000 -0.02864 17.236 20.000 -17.400 18.873 0.02291 22.000 26.000 13.920 25.540 -0.37855 Page 7 US Version 5.0.1 Page 1 Section: 4x2.5Zl6.sct Michael Dale, P.E. 4 x 2.5 Z 16 Gage Mako Steel, Inc. LGSI Library 5650 El Camino Real,#235 Rev. Date: 1/112003 12:00:00 PM Carlsbad, California 92008 By: RSG Software Ph: 760/448-1760, Fax: 760/448-1761 mdale@makosteel.com ON Section Inputs Material: A60'7 Class 2 Grade 55 No strength increase from cold work of forming. Modulus of Elasticity, E 29500 ksi Yield Strength, Fy 55 ksi Tensile Strength, Fu 67.7 ksi Warping Constant Override, Cw 0 in^6 Torsion Constant Override, J 0 in^4 Z-Section, Thickness 0.059 in Placement of Part from Origin: X to center of gravity 0 in Y to center of gravity 0 in Outside dimensions, Open shape Length Angle Radius Web k Hole Size Distance (in) (deq) (in) Coef. (in) (in) 1 0.9110 -50.000 0.18750 None 0.000 0.0000 0.4555 2 2.3750 0.000 0.18750 Single 0.000 0.0000 1.1875 3 4.0000 90.000 0.18750 Zee 0.000 0.0000 2.0000 4 2.1250 0.000 0.18750 Single 0.000 0.0000 1.0625 5 0.9110 -50.000 0.18750 None 0.000 0.0000 0.4555 Full Section Properties Area 0.58626 in^2 wt. 0.0019933 k/ft Width 9.9367 in IX 1.5446 in^4 rx 1.6232 in Ixy 0.9856 in^4 SX(t) 0.75363 in^3 y(t) 2.0496 in a -38.359 deg Sx(b) 0.79194 in^3 y(b) 1.9504 in Height 4.0000 in Iy 1.0793 in^4 ry 1.3568 in X0 -0.0258 in Sy(l) 0.37821, in^3 X(l) 2.8533 in Yo -0.2314 in Sy(r) 0.39122 in^3 x(r) 2.7588 in ]X -0.0186 in Width 5.6122 in jy 0.2565 in Il 2.3247 in^4 rl 1.9913 in 12 0.2993 in^4 r2 0.7145 in Ic 2.6239 in^4 rc 2.1156 in Cw 2.7382 in^6 Io 2.6557 in^4 ro 2.1284 in 1 0.0006803 in^4 Page 8 CFS Version 9.0.4 Page 1 Analysis:Analysis 2.cfsa 10 ft Tall Beam-Column ROOF POSTS, TYP Rev. Date: 8/16/2016 LP = 5-PSF UNIFORM PARTITION LATERAL LOAD Printed: 8/16/2016 Member Check - 2010 North American Specification - US (ASD) 111111 11111 111111 111111 11111 111111 111111 11111 111111 11111 11111 11 111111 Load Combination: Combination 16 D + .75Lr + .75LP Design Parameters at 5.000 ft: b 6 b'.'f.'t Ly 10.000 ft Lt 10.000 ft X Ky 1.0000 Kt 1.0000 ka����i a 1'F;1��:�',A`610'7'_Cla s s 2 Grade 55, Fy=57 ksi Cox 1.1364 Cby 1.0000 ex -1.0000 in CmX 1.0000 Cmy 1.0000 ey 0.0000 in Braced Flange: Top k� 0 k Red. Factor, R: 0.7 Lm 10.000 ft Loads: P MX Vy My VX (k) (k-in) (k) (k-in) (k) Total 1.2750 -2.813 0.0000 0.000 0.0000 Applied 1.2750 -2.813 0.0000 -2.372 0.0000 Strength 5.0748 10.664 2.4402 7.104 4 .0477 Effective section properties at applied loads: Ae 0.44033 in^2 Ixe 1.2005 in^4 Iye 0.3653 in^4 Sxe(t) 0.60027 in^3 Sye(l) 0.42429 in^3 Sxe(b) 0.60019 in^3 Sye(r) 0.22284 in^3 X!AS Z E.4.' P Mk M'�- 0 '51 33 6 k- 0 .2 9 1'.Y� 0 ,4 0'.�8'7 .1. XA S:L Zj..' 5 -Z': 1 2 q. ... ....... ...... . Section does not meet all requirements of NAS D6.1.3. Value of x in NAS D6.1.3 assumed to be 0.5. Maximum Shears, Moments, and Deflections DOO--- --- Load Combination: Combination 16, Y Direction Location Shear(l) Shear(r) Reaction (ft) (k) (k) (k) 0.000 0.000000 -0.093750 -0.093750 10.000 0.093750 O.00OOCO -0.093750 Location Moment Location Deflection Inflections (ft) (k-in) (ft) (in) (ft) 1.000 -2.8125 5.000 0.11913 Page 9 US Version 5.0.1 Page 1 Section: 4x2.5Cl8.sct Michael Dale, P.E. Channel 42.50.50.0466 Mako Steel, Inc. 5650 El Camino Real,#235 Rev. Date: 7/29/2011 12-50:48 PM Carlsbad, California 92008 By: Michael Dale, P.E. Ph: 760/448-1760, Fax: 760/448-1761 mdale@makosteel.com + Section Inputs Material: A607 Class 2 Grade 55 No strength increase from cold work of forming. Modulus of Elasticity, E 29500 ksi Yield Strength, Fy 55 ksi Tensile Strength, Fu 65 ksi Warping Constant Override, Cw 0 in^6 Torsion Constant Override, J 0 in^4 Part 3, Thickness 0.0466 in Placement of Part from Origin: X to center of gravity 0 in Y to center of gravity -8.6389e-7 in Outside dimensions, Open shape Length Angle Radius Web k Hole Size Distance (in) (deg) (in) Coef. (in) (in) 1 0.5000 270.000 0.18750 None 0.000 0.0000 0.2500 2 2.5000 180.000 0.18750 Single 0.000 0.0000 1.2500 3 4.0000 90.000 0.18750 Cee 0.000 0.0000 2.0000 4 2.5000 360.000 0.18750 Single 0.000 0.0000 1.2500 5 0.5000 270.000 0.18750 None 0.000 0.0000 0.2500 Full Section Properties 0EID-_--000--- Area 0.44045 in^2 wt. 0.0014975 k/ft Width 9.4517 in Ix 1.2005 in^4 rx 1.6509 in Ixy 0.0000 in^4 SX(t) 0.60024 in^3 y(t) 2.0000 in (X 0.000 deg Sx(b) 0.60024 in^3 y(b) 2.0000 in Height 4.0000 in Iy 0.3653 in^4 ry 0.9108 in X0 -2.0219 in Sy(l) 0.42450 in^3 X(l) 0.8606 in Yo 0.0000 in Sy(r) 0.22286 in^3 x(r) 1.6394 in ]X 2.7519 in Width 2.5000 in jy 0.0000 in T1 1.2005 in^4 rl 1. 6509 in 12 0.3653 in^4 r2 0.9108 in Tc 1.5658 in^4 rc 1.8855 in Cw 1.1912 in^6 10 3.3664 in^4 ro 2.7646 in 1 0.0003188 in^4 Page 10 POST TO BASE AT CONCRETE SLAB PuW� (6p,,3 — .6-D,).(Llo-Ld,) = 0.645-KIPS UPLIFT DUE TO WIND N5 := 4 NUMBER OF SCREWS FOR CONNECTION Pup3 - = 0.52 N5-Va3 USE (4)#12 TEKS AT POST BASE CLIP TO POST AND (1)CONCRETE ANCHOR AT POST BASE CLIP TO SLAB Pup,, := 0.968-KIPS USE 112" HILT[ KB-TZ WITH A MINIMUM OF 2" EMBEDMENT, WITH SPECIAL INSPECTION Page 11 Title Block Line 1 Project Title: You can change this area Engineer: Project 10: using the"Settings"menu item Project Descr: and then using the"Printing& Title Block"selection. Title Block Line 6 Primo.i13 AUG 2016.10 21 AN! 1463AD;-l�C�l6�CALC8-�-',1\1463 k, ff "F' tibbN V il� q:kl, X C, ROME 2�- X., NERCAL JNQ.Av Description SLAB BEARING WALLS 6 #3 BARS AT 18" OC �.b Calculations per ACI 318-11, IBC 2012,CBC 2013,ASCE 7-1 0 EACH WAY Load Combinations Used : IBC 2012 ,P V06 er e I g s�, fc 2.50 ksi Phi Values Flexure 0.90 1/2 fr= fc 7.50 375.0 psi Shear 0.750 0.850 W Density 145.0 pcf Ll Wt Factor 1.0 Elastic Modulus 2,850.Oksi Soil Subgrade Modulus 70.0 psi (inch deflection) -AX�-- ft,-AKK Load Combination IBC 2012 46 ty-Main Rebar 60.0 ksi Fy-Stirrups 40-0 ksi 36 In E Main Rebar 29,000.0 ksi E-Stirrups 29,000.0 ksi Stirrup Bar Size# # 3 Number of Resisting Legs Per Stirrup 2 Beam is supported on an elastic foundation, ...............-.............. ............................... .................................................................. ...................................................... .................. D(O.3) Lr(1.3)W(O.765) L(O.45) D(O.3) Lr(1.3)W(O.765) 36"w x 4" h Span=20.0 ft ............................................... ............ .................- ............ ................. ........................................... ................ rpis n.,dih :Do (O"r", 9" Rectangular Section, Width 36.0 in, Height 4.0 in Span#1 Reinforcing.... 243 at 2.0 in from Top,from 0.0 to 20.0 ft in this span Service loads entered.Load Factors will be applied for calculations. PIP, "Pq C:.A Beam self weight calculated and added to loads Load for Span Number I Uniform Load: L=0.150 ksf, Tributary Width=3.0 fl Point Load: D=0.30, Lr=1.30, W=0.7650 k 5.0 fl Point Load: D=0.30, Lr=1.30, W=0.7650 k 15.0 fl It S io S- J I MM I IWA i I�q ! " I!An, Maximum Bending Stress Ratio 0.630: 1 Maximum Deflection Section used for this span Typical Section Max Downward L+Lr+S Deflection 0.000 in Mu:Applied 1.762 k-ft Max Upward L+Lr+S Deflection 0.000 in Mn*Phi:Allowable 1.895 k-ft Max Downward Total Deflection 0.026 in Load Combination +1.20D+1.6OLr+0.50W+1,60 Max Upward Total Deflection 0.003 in Location of maximum on span 15.059 ft Span#where maximum occurs Span#1 Maximum Soil Pressure = 0.267 ksf at 5.11 ft LdComb: +D+0.750Lr+0.750L+0.4: Allowable Soil Pressure = 750.0 ksf OK .......... ............................I............ .............. .............................. ............. ...................... .......... .......... ......................................................................... ................. ....... qup q!r;prnpjh1 s Entire Beam Span Length Vu<PhiVc/2, Req'd Vs Not Reqd, usWstirnups spaced at 0.000 in [Mai-ru'rn'�Forqes fres, Load Combination Location(ft) Bending�tress Results (k-ft Segment Length Span# in Span Mu:Max Phil%e 1�tress Ratio MAXimum Sending Envelope Span#1 1 15.059 1.76 1.89 0.93 +1.40D+1.60H Title!Block Line 1 Project Title: You can change this area Engineer: Project ID: using the"Seftings"menu item Project Descr: and then using the"Printing& Title Block"selection. Title Block Line 6 Pnraea:i6AUG 2011G.i021ANI BdAfn b' ' "El n, as i1cf6iiifid' tibm`�- 4, -.4A --7, .6.7 R Description SLAB Load Combination Location(ft) Bending Stress Results k-ft Segment Length Span# in Span Mu:Max Phi'Mnx Stress Ratio Span#1 1 15.059 0.26 1.89 0.14 +1.20D+0.5OLr+1.60L+1.60H Span#1 1 15.059 0.63 1.89 0.33 +1.20D+1.60L+0.50S+1.60H Span#1 1 15.059 0.22 1.89 0.12 +1.20D+1.6OLr+0.50L+1.60H Span#1 1 15.059 1.52 1.89 0.80 +1.20D+1.6OLr+0.50W+1.60H Span#1 1 15.059 1.76 1.89 0.93 +1.20D+0.50L+1.60S+1.60H Span#1 1 15.059 0.22 1.89 0.12 +1.20D+1,60S+0.50W+1.60H Span#1 1 15.059 0.46 1.89 0.24 +1.20D+0.5OLr+0.50L+W+1.60H Span#1 1 15.059 1.11 1.89 0.58 +1.20D+0.50L+0.50S+W+1.60H Span#1 1 15.059 0.70 1.89 0.37 +1.20D+0.50L+0.70S+E+1.60H Span#1 1 15.059 0.22 1.89 0.12 +0.90D+W+0.90H Span#1 1 15.059 0.65 1.89 0.34 +0.90D+E+0.90H Span#1 1 15.059 0.17 1.89 0.09 TPv M)Qmp, red J Load Combination Span Max. DO Location in Span Load Combination Max."+"Defl Location in Span Span 1 1 0.0265 5.111 0.0000 0.000 .......... 96tand hear Inform ion, Span Distance V Vu (k) Mu d*Vu/Mu Phi*Vc Comment Phi*Vs Spacing(in) Load Combination Number (ft) (in) Actual Design (0) (k) (k) Req'd Suggest +1.20D+1.60L+0.50S+1.60H 1 0.00 2.00 0.10 0.10 0.00 1.00 5.54 Vu<PhiVc/2 Not Reqd 0.00 0.00 +1.20D+1.60L+0.50S+1.60H 1 0.24 2.00 0.10 0.10 0.00 1.00 5.54 Vu<PhiVc/2 Not Recid 0.00 0.00 +1.200+1.60L+0.50S+1.60H 1 0.47 2.00 0.10 0.10 0.00 1.00 5.54 Vu<PhiVcI2 Not Reqd 0.00 0.00 +1.20D+1.60L+0.50S+1.60H 1 0.71 2.00 0.10 0.10 0.00 1.00 5.54 Vu<PhiVc/2 Not Recid 0.00 0.00 +1.20D+1.60L+0.50S+1.60H 1 0.94 2.00 0.10 0.10 0.00 1.00 5.54 Vu<PhiVc/2 Not Reqd 0.00 0.00 +1.20D+1.60L+0.50S+1.60H 1 1-18 2.00 0.10 0.10 0.01 1.00 5.54 Vu<PhiVGt2 Not Recid 0.00 0.00 +1.20D+0.5OLr+1.60L+1.60H 1 1.41 2.00 0.10 0.10 0.02 1.00 5.54 Vu<PhiVct2 Not Recid 0.00 0.00 +1.20D+0.5OLr+1.60L+1.60H 1 1.65 2.00 0.12 0.12 0.02 1.00 5.54 Vu<PhiVc/2 Not Recid 0.00 0.00 +1.20D+O.5OLr+1.60L+1.60H 1 1.88 2.00 0.13 0.13 0,01 1.00 5.54 Vu<PhiVc/2 Not Reqd 0.00 0.00 +1.20D+1.6OLr+0.50L+1.60H 1 2.12 2.00 0.16 0.16 0.01 1.00 5.54 Vu<PhiVGt2 Not Recid 0.00 0.00 +1.20D+1.6OLr+0.60W+1.60H 1 2.35 2.00 0.22 &22 0.02 1.00 5.54 Vu<PhiVc/2 Not Recid 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 2.59 2.00 0.29 0.29 0.07 1.00 5.54 Vu<PhiVc/2 NotReqd 0.00 0.00 +1.20D+1-60Lr+0.50W+1.60H 1 2.82 2.00 0.37 0.37 0.13 1.00 5.54 Vu<PhiVGt2 Not Reqd 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 3.06 2.00 0.45 0.45 0.22 1.00 5.54 Vu<PhiVct2 Not Reqd 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 3.29 2.00 0.55 0.55 0.32 1.00 5.54 Vu<PhiVc/2 Not Recid 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 3.53 2.00 0.65 0.65 0.45 1.00 5.54 Vu<PhiVc/2 Not Reqd 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 3.76 2.00 0.76 0.76 0.59 1.00 5.54 Vu<PhiVc/2 Not Reqd 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 4.00 2.00 0.88 0.88 0.77 1.00 5.54 Vu<PhiVc/2 Not Reqd 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 4.24 2.00 1.00 1.00 0.97 1,00 5.54 Vu<PhiVc/2 Not Reqd 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 4.47 2.00 1.13 1.13 1.21 1.00 5.54 Vu<PhiVc/2 Not Reqd 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 4.71 2.00 1.26 1.26 1.47 1.00 5.54 Vu<PhiVcI2 NotReqd 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 4.94 2.00 1.40 1.40 1.76 1.00 5.54 Vu<PhiVc/2 NotReqd 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 5.18 2.00 -1.30 1.30 1.59 1.00 5.54 Vu<PhiVc/2 Not Reqd 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 5.41 2.00 -1.17 1.17 1.28 1.00 5.54 Vu<PhiVc/2 Not Reqd 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 5.65 2.00 -1.05 1.05 1.00 1.00 5.54 Vu<PhiVc/2 NotReqcI 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 5.88 2.00 -0.93 0.93 0.75 1.00 5.54 Vu<PhiVc/2 NotReqd 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 6.12 2.00 -0.82 0.82 0.53 1.00 5.54 Vu<PhiVc/2 NotReqcI 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 6.35 2.00 -0.71 0.71 PaWl 3 100 5.54 Vu<PhiVc/2 Not Reqd 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 6.59 2.00 -0.62 0.62 0.16 1.00 5.54 Vu<PhiVc/2 NotReqd 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 6.82 2.00 -0.53 0.53 0.01 1.00 5.54 Vu<PhiVc/2 NotReqcI 0.00 0.00 Title Block Line 1 Project Title: it You can change this area Engineer: Project ID: using the"Settings"menu item Project Descr: and then using the"Printing& Title Block"selection. Title Block Line 6 Pnwo.16 AUG 2016,10 21 AN! 3AD TM&MGAL W463,e 6'1,�, .Beam`dh`,' I Tou''nJdAtidh -'ENERCALC,'IfN, -V&.6A .67,:,� Descrption: SLAB ;1 Vbifa(166 i Jn,-f fiDn"; 0 Span Distance V Vu (k) Mu d*Vu/Mu Phi.vc Comment Phi*Vs Spacing(in) Load Combination Number (ft) (in) Actual Design (k-ft) (k) (k) Req'd Suggest +1.20D+1.6OLr+0.50W+1.60H 1 7.06 2.00 -0.45 0.45 0.12 1.00 5.54 Vu<PhiVcI2 Not Reqd 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 7.29 2.00 -0.38 0.38 0.23 1.00 5.54 Vu<PhiVct2 Not Reqd 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 7.53 2.00 -0.32 0.32 0.32 1.00 5.54 Vu<PhiVc/2 Not Reqd 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 7.76 2.00 -0.26 0.26 0.40 1.00 5.54 Vu<PhiVc/2 Not Reqd 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 8.00 2.00 -0.21 0.21 0.47 1.00 5.54 Vu<PhiVc/2 Not Reqd 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 8.24 2.00 -0.17 0.17 0.52 1.00 5.54 Vu<PhiVcI2 Not Reqd 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 8.47 2.00 -0.13 0.13 0.57 0.94 5.52 Vu<PhiVc/2 NotReqd 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 8.71 2.00 -0.10 0.10 0.60 0.67 5.41 Vu<PhiVc/2 Not Reqd 0.00 0.00 +1.20D+1.60L+0.50S+1.60H 1 8.94 2.00 0.09 0.09 0.08 1.00 5.54 Vu<PhiVc/2 Not Reqd 0.00 0.00 +1.20D+1.60L+0.50S+1.60H 1 9.18 2.00 0.09 0.09 0.09 1.00 5.54 Vu<PhiVc/2 NotReqd 0.00 0.00 +1.20D+1.60L+0.50S+1.60H 1 9.41 2.00 0.10 0.10 0.09 1.00 5.54 Vu<PhiVc/2 Not Reqd 0.00 0.00 +1.20D+1.60L+0.50S+1.60H 1 9-65 2.00 0.10 0.10 0.09 1.00 5.54 Vu<PhiVG12 Not Reqd 0.00 0.00 +1.20D+0.5OLr+1.60L+1.60H 1 9.88 2.00 0.10 0.10 0.25 1.00 5.54 Vu<PhiVc/2 Not Reqd 0.00 0.00 +1.20D+0.5OLr+1.60L+1.60H 1 10-12 2.00 0.11 0.11 0.25 1.00 5.54 Vu<PhiVc/2 Not Reqd 0.00 0.00 +1.20D+0.5OLr+1.60L+1,60H 1 10.35 2.00 0.12 0.12 0.25 1.00 5.54 Vu<PhiVcI2 Not Reqd 0.00 0.00 +1.20D+0.5OLr+1.60L+1.60H 1 10.59 2.00 0.12 0.12 0.24 1.00 5.54 Vu<PhiVc/2 Not Reqd 0.00 0.00 +1.20D+0.5OLr+1.60L+1.60H 1 10.82 2.00 0.13 0.13 0.24 1.00 5.54 Vu<PhiVc/2 Not Reqd 0.00 0.00 +1.20D+1.6OLr+0.50L+1.60H 1 11.06 2.00 0.15 0.15 0.55 1.00 5.54 Vu<PhiVc/2 Not Reqd 0.00 0.00 +1.20D+1.6OLr+0.50L+1.60H 1 11.29 2.00 0.17 0.17 0.52 1.00 5.54 Vu<PhiVc/2 Not Reqd 0.00 0.00 +1.20D+1.6OLr+0.50L+1.60H 1 11.53 2.00 0.21 011 0.49 1.00 5.54 Vu<PhiVc/2 Not Reqd 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 11.76 2.00 0.25 0.25 0.52 1.00 5.54 Vu<PhiVc/2 Not Reqd 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 12.00 2.00 0.30 0.30 0.47 1.00 5.54 Vu<PhiVc/2 Not Reqd 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 12.24 2.00 0.35 0.35 0.40 1.00 5.54 Vu<PhiVct2 Not Reqd 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 12.47 2.00 0.42 0.42 0.32 1.00 5.54 Vu<PhiVct2 Not Reqd 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 12.71 2.00 0.49 0.49 0.23 1.00 5.54 Vu<PhiVc/2 Not Reqd 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 12.94 2.00 0.57 0.57 0.12 1.00 5.54 Vu<PhiVc/2 Not Reqd 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 13.18 2.00 0.65 0.65 0.01 1.00 5.54 Vu<PhiVc/2 NotReqd 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 13.41 2.00 0.75 0.75 0.16 1.00 5.54 Vu<PhiVct2 NotReqd 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 13.65 2.00 0.85 0.85 0.33 1.00 5.54 Vu<PhiVc/2 Not Reqd 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 13.88 2.00 0.96 0.96 0.53 1.00 5.54 Vu<PhiVct2 Not Reqd 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 14.12 2.00 1.08 1.08 0.75 1.00 5.54 Vu<PhiVct2 NotReqd 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 14.35 2.00 1.20 1.20 1.00 1.00 5.54 Vu<PhiVc/2 Not Reqd 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 14.59 2.00 1.33 1,33 1.28 1.00 5.54 Vu<PhiVc/2 NotReqd 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 14.82 2.00 1.46 1.46 1.59 1.00 5.54 Vu<PhiVcI2 Not Reqd 0.00 0.00 +1.20D+1.6OLr+0.60W+1.60H 1 15.06 2.00 -1.23 11.23 1.76 1.00 5.54 Vu<PhiVct2 NotReqd 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 15.29 2.00 -1.10 1.10 1.47 1.00 5.54 Vu<PhiVct2 Not Reqd 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 15.53 2.00 -0.97 0.97 1.21 1.00 5.54 Vu<PhiVc/2 NotReqd 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 15.76 2.00 -0.85 0.85 0.97 1.00 5.54 Vu<PhiVct2 NotReqd 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 16-00 2.00 -0.73 0.73 0.77 1.00 5.54 Vu<PhiVc/2 Not Reqd 0.00 0.00 +1.20D+1.6OLr+0,50W+1.60H 1 16.24 2.00 -0.62 0.62 0.59 1.00 5.54 Vu<PhiVc/2 Not Reqd 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 16.47 2.00 -0.52 0.52 0.45 1.00 5.54 Vu<PhiVct2 Not Reqd 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 16.71 2.00 -0.42 0.42 0.32 1.00 5.54 Vu<PhiVc/2 Not Reqd 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 16.94 2.00 -0.33 0.33 0.22 1.00 5.54 Vu<PhiVct2 Not Reqd 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 17.18 2.00 -0.25 0.25 0.13 1.00 5.54 Vu<PhiVc/2 NotReqd 0.00 0.00 +1.20D+l.6OLr+0.50W+1.60H 1 17.41 2.00 -0.18 OA8 0.07 1.00 5.54 Vu<PhiVct2 NotReqd 0.00 0.00 +1.20D+1.6OLr+0.50W+1.60H 1 17.65 2.00 -0.12 0.12 0.02 1.00 5.54 Vu<PhiVct2 NotReqd 0.00 0.00 +1.20D+1.60L+0.50S+1.60H 1 17.88 2.00 0.09 0.09 0.00 1.00 5.54 Vu<PhiVc/2 Not Reqd 0.00 0.00 +1.20D+1.60L+0.50S+1.60H 1 18.12 2.00 0.10 0.10 0.00 1.00 5.54 Vu<PhjVc/2 NotReqd 0.00 0.00 +1.20D+1.60L+0.50S+1.60H 1 18.35 2.00 0.10 0.10 0.01 1.00 5.54 Vu<PhiVct2 Not Reqd 0.00 0.00 +1.20D+0.5OLr+1.60L+1.60H 1 18.59 2.00 0.11 0.11 0.02 1.00 5.54 Vu<PhiVc/2 Not Reqd 0.00 0.00 +1.20D+0.5OLr+1.60L+1.60H 1 18.82 2.00 0.11 0.11 0.01 1.00 5.54 Vu<PhiVc/2 Not Reqd 0.00 0.00 +1.20D+0.5OLr+1.60L+1.60H 1 19.06 2.00 0.12 0.12 Pad,04 1.00 5.54 Vu<PhiVcI2 Not Reqd 0.00 0.00 +1.20D+0.5OLr+1.60L+1.60H 1 19.29 2.00 0.12 0.12 0.01 1.00 5.54 Vu<PhiVcI2 Not Reqd 0.00 0.00 +1.20D+0.5OLr+1.60L+1.60H 1 19.53 HO 0.11 0.11 0.00 1.00 5.54 Vu<PhiVc/2 Not Reqd 0.00 0.00 TitIOBlock Line 1 Project Title: You can change this area Engineer: Project I D: using the"Settings"menu item Project Descr: and then using the"Printing& Title Block"selection. Title Block Line 6 Fmqo:i6 AUG 2016.10*2WO N 0, X B e""A n' 'E I A i t i I d,F4 b U h d d t� Description SLAB "b4t 06d,111' 'n 1. A a— 'On Span Distance V Vu (k) Mu d*Vu/Mu Phi*Vc Comment Phi*Vs Spacing(in) Load Combination Number (ft) (in) Actual Design (0) (k) (k) Req'd Suggest +1.20D+0.5OLr+1.60L+1.60H 1 19.76 2.00 0.11 0.11 0.00 1.00 5.54 Vu<PhiVc/2 Not Reqd 0.00 0.00 Page 15 CHECK EXISTING SLAB UNDER POST FOR PUNCHING: Pd := 0.30-KIPS ROOF DEAD LOAD P,:= 1.30-KIPS ROOF LIVE LOAD P,:= 0.765-KIPS WIND LOAD FIND LOAD COMBINATIONS REACTIONS CASE#3: D+ (Lr+ S) P31:= Pd + P,= 1.6-KIPS POINT LOADS ASSUME: t:= 4-IN ACTUAL SLAB THICKNESS fc:= 2500 PSI CONCRETE STRENGTH Fv:=-,F2-500-2-PSI q,s:= 750-PSF ALLOWABLE SLAB SOIL PRESSURE FIND SHEAR PERIMETER FOR ROOF POST MINI CLIP IS A'L'3 1/2"x2"x3/16" t t bo:= 2- 3.5 + — .IN + 2.(2 + — -IN = 27-IN IN) IN) CHECK SLAB IN FLEXTURE TO SPREAD LOAD OUT TO 750 PSF REFERENCE:ACI 318 BUILDING CODE REQUIREMENT FOR STRUCTURAL PLAIN CONCRETE COLUMN LOAD IS... P3,= 1.6-KIPS C) �"k Ul BASE PLATE IS 3 1/2"x2" A:= 3.5.2-SI 7-SI SLAB ON GRADE IS 4" THICK, I I YF -17 l;;i, f'c = 2,500 PSI LOAD FACTOR: LF:= P,.1.7 + Pd-1.4 1.644 PS+ Pd v111\1 IF: AREA REQUIRED FROM SOIL CAPACITY _T ',T_ Areq := P3a = 2.133-SF L:=�_A_req = 17.527-IN qas ANALYSIS ASSUMES FULL DEPTH CRACK IN CONCRETE INA L 17.53-IN SQUARE AND DESIGNS REMAINDERAS UNREINFORCED FOOTING qu := LF.qa, = 1233-PSF L— 3-IN 2 qu. 2 2 IN-LB t .1-IN Mu-IN Mu := - 225.841. —S 2.667-Cl fb:= — = 84.691-PSI 2 IN 6 S, Fb:= 5..65.�,Ff_c.PSI = 162.5-PSI > fb = 84.7-PSI OK Page 16 CHECK PUNCHING SHEAR: 3-Pu PU:= P3,-LF= 2.63-KIPS vu := — = 36.528-PSI 2-bo-t Vu:= .65.4.-,Ff—c-PSI = 130-PSI > vu = 36.5-PSI OK THE EXISTING 4"THICK SLAB ON GRADE APPEARS TO BE ADEQUATE CHECK PERIMETER FOOTING DESIGN: END WALL-WORSE CASE wp.ftg := (D,+ S).5.0-FT+ 10-FT-5PSF= 195-PLF UNIFORM LOAD ON FTG q,:= 1500-PSF ALLOWAB LE SOI L B EARI NG wp ftg wpftgl := qa = 1.56-IN MINIMUM 12" V\11DE MINIMUM STEEL REQUIRED: A,:= (.5 2 IN)2.7T= 0.196-SI AREA OF (1)#4 REBAR Asreq := (12-IN-12-IN)-0.0018 = 0.259-Sl Np.ftgl := �sreq = 1.32 USE A MIN (2)#4 REBAR As USE 12"xi2" FOOTING CONTINUOUS W/ (1)#4 REBAR CONTINUOUS TOP AND BOTTOM Page 17 CHECK WALL PANEL DESIGNAND CONNECTIONS: MATHCAD UNITS ARE... IN := IL LB := IM Sl := IN 2 FT:= 12-fN SF:= FT' CI:= IN' KIPS:= 1000-LB KSI:= 1000-LB PSF:= LB PLF := LB PSI:= LB E:= 29500-KSI Fy:= 55-KSI si SF FT si WIND: 126 MPH EXPOSURE "C" CHECK WALL PANELS: P,,4 37.56-PSF-0.6= 22.54-PSF =DESIGN WTNIID LOAD IN ZON E 4 Pw5 46.14-PSF-0.6= 27.8-PSF =DESIGN! WIND 1.OAD IN ZONE 5 CHECK IIANEUTO SPAN 4;'-3"BETWEEN SUPPORTS FOR WIND PRE,SSI RES. FROM RkNEL PROPER'rIESTABI.E PER MzVNIUFACTURER(ATTACHED)FOR 26 GA. TOP IN COMPRESSION SXP:= 0.0405-Cl IXP:= 0.0373-IN 4 (POSITIVE) BOTTOM IN COMPRESSION S,,:= 0.0386-CI 1,,:= 0.0240.IN4 (NEGATIVEI Lp:= 5.25-FT MAXPANELSPAN Fyp:= 80-KSI-0.75 = 60-KSl PANEL YIELD STRENGTH PP:= 33.00-PSF MAXIMUM POSITIVE PRESSURE,PER MANUF SPEC'S P,:� -34.50.PSF MAXIMUM NEGATIVE PRESSURE,PER MANUF SPEC'S THERET-ORE, PANEL IS ADE0 I IA TF 4 T A 1,10 A.Rl_'.,jS k�Q.R 5�-3" SP-4.NS CHECK WALL PANEL CONNECTION:. DETERMINE REQUIRED SCREW SPACING FOR WIND SUCTION. PANEL WILL BE SCREWED DIRECTLY TO 18 GAUGE HORIZONTAL GIRTS,EAVE TRACKS,AND BASE TRACKS. THE ALLOWABLE PULLOUT FOR#12 TEK INTO 18 GAUGE MATERIAL IS 0.132-KIPS*1.44=0.190-KIPS. THE ALLOWABLE PULLOVER FOR#12 TEK THROUGH 26 GA MATERIAL IS 0.673-KIPS/3=0.224-KIPS DESIGN PULLOUT FORCE IS..... T3 := P,4-Lp'12-IN = 0.118-KIPS REQUIRED TENSION IN ZONE 4 T4:= P,5.LP*6-IN = 0.073-KIPS REQUIRED TENSION IN ZONE 5 T,2:= 0.190-KIPS ALLOWABLE TENSION THEREFORE, USE 26GAMcELROY MULT-RIB PANEL SPANNING VERTICALLY BETWEEN T14E CONT EAVE CHANNEL,HORIZONTAL GIRTS,AND CONT BOTTOM CHANNEL WITH(4)#12 SCREWS AT EACH SUPPORT. Page 18 CIO APOFIATE: 0,FFICE-45,0, Bb,� 11,Ii4t Sil"VEPORT, L A -0�t 74-1­8660-',� :FAX p,�,bi 7 1 4, 47-8b2� T t"CXWN I CATI" Itt U INAMSETUN Issue Date June 1,2006 No.07-235-06 Multi-Rib 36' COVERAGE SECTION PROPERTIES GAUGE FY EIGHT I kVa. I Pa-end Pa-int 1,,, S I� Se Ma (KSI) (PSF) ip/ft Ibs/ft- Ilbs/ft. (in.4/ft.) I (in 3/ft kipMin./ft.I (in 4/ft ./ft kip-in./ft. I I I I I (in ) 1 26 1 80.01 0.90 1 0,13987 1 161,44 1 282,01-1-0.0373 1 0.0405 1 1.4537 1 0_0240 1 0.0386 1 1�3857_1 1.Section properties are calculated in accordance with the 2001 AlSl North 4.Ix is for deflection determination. American Specification for the Design of Cold-Formed Steel Structural Members. 5.Se is for bending. 2.Va is the allowable shear. 6.Me is the allowable bending moment. 3.Pa is the allowable load for web rripp4rig on end&interior supports 7.All values are for one foot of panel width. Allowable Uniform Loads (PSF) S 3an in Feet Span Type Load Type _50 ZOO 2_10 10 Q 3.50 400 4.50 5.0C -5�50 6.00 6.50 TOG 7.150 3.00 8.50 u. Positive Wind 430 242 155 107 79 60 47 38 32 26 22 19 17 15 13 11 Negative Wind 410 230 147 102 75 57 45 36 30 25 21 18 16 14 12 11 Single Live 430 242 155 107 79 60 47 38 32 26 22 19 17 15 13 11 Deflection(LJ180) 966 407 208 120 76 50 35 26 19 15 11 9 7 6 5 4 Deflection(U240) 724 1 305 156 90 1 57 38 26 1 19 14 1 11 8 1 7 1 5 4 1 3 1 3 PositiveWind 359 213 140 98 73 56 44 36 30 25 21 18 16 14 17 11 Negative Wind 372 222 146 103 76 59 46 38 31 26 22 19 17 15 13 11 2 Span Live 359 213 140 98 73 56 44 36 30 25 21 18 16 14 12 11 Deflection(LJ180) 1912 806 413 239 150 100 70 51 38 29 23 18 15 12 10 8 Deflection(U240) 1434 605 1 309 179 112 75 53 38 1 29 22 17 14 11 9 7 6 PositiveWind 427 258 171 1 121 90 70 55 45 37 31 1 27 1 23 20 1 17 1 15 14 Negative Wind 442 266 178 127 94 73 58 47 39 33 28 24 21 18 16 14 3 Span Live 428 258 171 121 90 1 70 1 55 45 37 31 27 23 20 17 15 14 Deflection(L1180) 1497 631 323 187 117 78 55 40 30 23 18 14 11 9 8 6 Deflection(U240) 1123 473 242 140 88 59 41 30 22 17 13 11 8 7 6 5 PositiveWind 406 244 161 114 84 65 52 1 42 35 29 25 21 19 16 14 13 Negative Wind 420 253 168 119 88 68 54 44 1 36 30 1 26 1 22 19 17 15 13 4 Span Live 406 244 161 114 1 84 65 52 42 1 35 29 1 25 1 21 1 19 16 14 13 Deflection(IJ180) 1590 670 343 198 125 B3 58 42 32 24 19 15 1 12 10 8 7 �Deflch',n''(1140) 1192 503 257 149 93 62 44 32 1 24 18 14 1 11 1 9 7 6 5 Notes: 1.AJlowable uniform loads are based upon equal Span lengths. 2.Positive Wind is wind pressure and is NOT increased by 33 1/3%. 3.Negative Wind is wind suction or uplift and is NOT increased by 33 1/3%. 4.Live is the allowable live or snow load. 5.Deflection(IJ180)is the allowable load that limits the panel's deflection to L11 80 while under positive or live load. 6.Deflection(U240)is the allowable load that limits the panel's deflection to L/240 while under positive or live load. 7.The weight of the panel has NOT been deducted from the allowable loads. 8.Positive Wind,Negative Wind,and Live Load values are limited to combined shear&bending using Eq.C3.3.1-1 of the AlSl Specification. 9.Positive Wind and Live Load values are limited by web crippling using a bearing length of2". 10.Web crippling values are determined using a ratio of the uniform load actually supported by the top flanges of the section. RATE 0,,rFx% LWI$' JANIA P�i SOUTHEAST�QIVISt0N PEACHITREEL'Q i$A WESI-Ft3f jVYISION -:#0ELA.NT,) V1310 KOM,HUA6T DI L IN SOYTtiWEST DIVISION - BOSMEq CITY�LA sIxEppASS,qkvls�ON- L WISPW�XY 'r )( 61 1 1&1 -i q - . �E VMS Tt ASDI.W.ION -U�JiKEL�TX G)�EAT LAKEi'� VISION MARSHA-C,M11 CHECK EXTERIOR STUD BEARING WALLS: DESIGN LOADS: S:= 25-PSF ROOF SNOW LOAD D,:= 5-PSF ROOFDEADLOAD PU := 54.49-PSF WIND UPLIFT PRESSURE TOPTRACK DESIGN FOR 5'-0"SPAN LT:= 5.0-FT ROOF DECK TO CONTRIBUTE 2'-6"FT.TO SIDE WALLS THEREFORE... �2b:= 1.67 WT:= (S+ D,)-2.5-FT= 75-PLF UNIFORM LOAD(L+D) WT,,:= (0.6-P,, - 0.6-D,)-2.5-FT= 74.23-PLF UNIFORM LOAD(0.6W-0.6D) MT:= WT.LT 2 = 2227-IN-LB MAXIMUM MOMENT 10 USE 'U'4-3116"x3"xl6 GA. S,, := 0.250-Cl I:= 0.498-IN 4 ��b-MT MY:= (S,)-Fy= 13750-IN-LB MY = 0.27 OK < 1.0 CHECK DEFLECTION W-1-L 1,4 L-1, A:= 0.0069- 0.04-IN 1577 > 180 OK E-1 DESIGN CONTINUITY SPLICE: (INVERTTRACK AND SCREWEACH SIDE OF SPLICE) USE (2)#12 SCREWS AT 6" SPACING Va:= 0.430-KIPS= 0.43KIPS ALLOWABLE SHEAR FOR#12 TEKS INTO 16GA MATERIAL M.1, Ma:= Va-2-6-IN = 5160-IN-LB — = 0.43 OK Ma TOP TRACK CONNECTION TO STUDS: USE(1)#12 SCREW FAC14 SIDE TO CONNECT TOP TRACK TO STUD. THIS CONNECTION IS NOT TO CARRY SHEAR LOA D. THE STUD MUST BE DIRECTLY BEARING INTO TOPAND BOTTOM TRACKS. Page 20 CFS Version 5.0.1 Page 1 Section: 4x3Ul6.sct Michael Dale, P.E. Channel 4.18750-16 Gage MAKO Steel, Inc. Rev. Date: 3/26/2007 1:53:35 PM By: Michael Dale, P.E. Section Inputs 000---1111:1=111E]---E100---LjLj-j--EIEIEI---E100 Material: A60-/ Class 2 Grade 55 No strength increase from cold work of forming. Modulus of Elasticity, E 29500 ksi Yield Strength, Fy 55 ksi Tensile Strength, Fu 65 ksi Warping Constant Override, Cw 0 in^6 Torsion Constant Override, J 0 in^4 Channel, Thickness 0.0566 in (16 Gage) Placement of Part from Origin: X to center of gravity 0 in Y to center of gravity 0 in Outside dimensions, Open shape Length Angie Radius Web k Hole Size Distance (in) (deg) (in) Coef. (in) (in) 1 3.0000 180.000 0.18750 Single 0.000 0.0000 1.5000 2 4.1873 90.000 0.18-750 Cee 0.000 0.0000 2.0938 3 3.0000 0.000 0.18750 Single 0.000 0.0000 1.5000 Full Section Properties --LJLJLJ---LJLJ-J--LJLJLJ---LJLJLA---LJLJ-J--LJLJLJ---LJLJLJ---LJLJ-J--UULJ---LJLJLJ---LJLJ-J--Lj--LJULJ-- Area 0.559V2 in^2 Wt. 0.0019030 k/ft Width 9.8891 in Ix 1.7215 in^4 rx 1.7538 in Ixy 0.0000 in^4 SX(t) 0.82223 in^3 y(t) 2.0938 in 0.000 deg Sx(b) 0.82223 in^3 y(b) 2.0938 in Height 4.1875 in Iy 0.5434 in^4 ry 0.9853 in X0 -2. 1253 in SY(l) 0.58937 in^3 X(l) 0.9219 in Yo 0.0000 in Sy(r) 0.26147 in^3 x(r) 2.0781 in 3x 2.9960 in Width 3.0000 in jy 0.0000 in Tl 1.7215 in^4 rl 1.7538 in 12 0.5434 in^4 r2 0.9853 in Ic 2.2649 in^4 rc 2.0116 in CW 1.5722 in^6 10 4.7931 in^4 ro 2.9263 in 1 0.0005977 in^4 Page 21 CHECK EXTERIOR WALL GIRTS: GIRT DESIGN FOR 5'-0"SPAN LG := 5.0-FT ROOF DECKTO CONTRIBUTE 5'-6"FT.T0 SIDE WALLS THEREFORE... WG:= Pw5-5.50-FT= 152.92-PLF UNIFORMWINDLOAD WG LG 2 MG:= 8 = 5735-IN-LB MAXIMUM MOMENT USE 'C'4"x2 1/2"xl8 GA. S,2:= 0.446-Cl 12 := 0.999-IN 4 Qb'MG M, := (S,2)'Fy= 24530-IN.LB mx = 0.39 OK < 1.0 CHECK DEFLECTION 5WG-LG 4 LG AG:= 0.07-IN — = 822 > 180 OK -384-E-12 AG V,2:= 0.308-KIPS 0.31-KIPS ALLOWABLE SREAR FOR#12 TEKS INTO 18GA MATERIAL WG-LG PG PG:= 2 0.38-KIPS 4'V,2 = 0.31 <1.00 OK USE 'L'3"x3"xl6GA CLIP ANGLE WITH (4)#12 TEKS EACH LEG Page 22 DESIGN STUDS SUPPORTING ROOF WITH WIND METAL SIDING-NON FIREWALL FOR EXTERIOR SIDE WALLS Rdl := (2.50-FT-5.0-FT)-D,= 0.063-KIPS ROOFDEADLOAD Rll := (2.50-FT-5.0-FT).S= 0.313-KIPS ROOF SNOW LOAD PER FOLLOWING ALLOWABLE AXIAL LOAD CALCULATIONS... USE 'C'4x2 1/2xl8GA.POSTS UP TO 8'-6"HT.SPACEDAT 5'-0"OC WITH HORIZONTAL G IRTS AT MID-HGHT CHECK STUDS FOR COMBINED WIND WIND LOADING @ 126 MPH,EXPOSURE C P,, := 33).93-PSF ELEMENTS AND COMPONENTS IN ZONE4 Pw2 := 39.08-PSF ELEMENTSAND COMPONENTS IN ZONE 5 Hl := 8.50-FT HEIGHT OF ROOF POST Sl := 5.0-FT POST SPACING WINDAT a, := 4.25-FT HEIGHTOFGIRTAFF bl := H, – a, = 4.25-FT HI Wl := (P�',)­ = 144.2-PLF UNIFORM LOAD ON POST Pl := WI-Sl = 0.72-KIPS POINTLOAD 2 CHECK DEFLECTION: H, A, := 0.16-IN — = 638 OK At USE A MIN 26 GA METAL SIDING SPANNING VERTICALLY BETWEEN TOP TRACK/RAKE ANGLE/HORIZ GIRT/ BOTTOM TRACK WITH 'C'4"x2 1/2"xl6GA POSTS AT 5'-0" ON CENTER WITH 2-ROWS OF HORIZONTAL GIRTS EQUALLY SPACED AT 3'-10*'ON CENTER. Page 23 CIFS Version 9.0.4 Page 1 Analysis:Analysis sw-8ft6.cfsa 8.5 ft Tall Beam-Column Rev. Date: 8/16/2016 SIDE WALL ROOF POSTS, TYP Printed: 8/16/2016 Member Check - 2010 North American Specification - US (ASD) 111111 1111 1 111111 111111 1111 1 111111 111111 H 1 111111 111111 11111 11 111111 Load Combination: D+0.75 (0.6W+L+Lr) Design Parameters at 4.2500 ft, Left side: Lx 8.5000 ft Ly 4 .2500 ft Lt 4 .2500 ft Kx 1.0000 Ky 1.0000 Kt 1.0000 *.......... Material Type: A607 Class 2 Grade 551 Fy=55 ksi Cbx 1.6612 Cby 1.0000 ex 0.0000 in CmX 1.0000 Cmy 1.0000 ey 0.0000 in Braced Flange: None k� 0 k Red. Factor, R: 0 Lm 8.5000 ft Loads: P MX Vy My VX (k) (k-in) (k) (k-in) (k) Total 1.5650 8.221 0.0000 0.000 0.0000 Applied 1.5650 8.221 0.0000 0.000 0.0000 Strength 8.3864 21.681 3.8424 10.830 4.8845 Effective section properties at applied loads: Ae 0.58631 in^2 Ixe 1.5596 in^4 lye 0.5325 in^4 Sxe(t) 0.77980 in^3 Sye(l) 0.56131 in^3 Sxe(b) 0.77980 in^3 Sye(r) 0.34321 in^3 Interaction Equations NAS Eq. C5.2.1-1 (P, Mx, My) 0.187 + 0.405 + 0.000 = 0.592 <= 1.0 NAS Eq. C5.2.1-2 (P, Mx, My) 0.120 + 0.379 + 0.000 = 0.499 <= 1.0 NAS Eq. C3.3.1-1 (MX, VY) Sqrt(O.138 + 0.000)= 0.371 <= 1.0 NAS Eq. C3.3.1-1 (my, VX) Sqrt(O.000 + 0.000)= 0.000 <= 1.0 Maximum Shears, Moments, and Deflections --UULJ---Liu-]--LJUIJ---ULJU---UU-J--LJLJLJ---LJLJLJ---LIU-J--LJUU---UULJ---ULJ-J--U--LJLJLJ-- Load Combination: D+0.75(0.6W+L+Lr) , Y Direction Location Shear(l) Shear(r) Reaction (ft) (k) (k) (k) 0.0000 0.00000 0.16200 0.16200 8.5000 -0.16200 0.00000 0.16200 Location Moment Location Deflection Inflections (ft) (k-in) (ft) (in) (ft) 4.2500 8.2215 4.2500 -0.15569 Page 24 SIMPLE DOOR JAMB SPAN MATHCAD UNITS ARE... LB–_ 1M IN =_ 1L FT–= 12-IN SI IN 2 SF –_ FT2 CI IN' KIPS =_ 1000-LB LB LB LB LB PSF=_ — PSI — PLF — KSI 1000.— Fy 55 KSI E=_ 29500.KSI FT 2 IN 2 FT IN 2 DESIGN LOADS: ROOF LIVE LOAD Lr:= 25.0-PSF ROOFDEADLOAD Dr:= 5.0-PSF WIND LOADING @ 126 MPH HORIZONTAL--> P,:= 20.23-PSF UPLIFT --> P,:= 54.49-PSF MOMENT: Ll := 8.67-FT DOOROPENING Qb:= 1.67 w:= (Lr+ Dr).2.5-FT– 75-PLF UNIFORM LOAD S 4-D U-1wi := (0.6Pu + 0.6-Dr).2.5-FT= 89.2-PLF UNIFORM LOAD 0.6W-0.61) uAv 1-L, M := — = 8.049-IN-KIPS MAXIMUM MOMENT 10 TRYA COMIBINE'U'4-3/16"x3"xl6GA CONTINUOUS TOP TRACK TOPTRACK— Syel := 0.2507-Cl Iyel := 0.4985-IN 4 HEADER=> Sye2 := 0.2081-Cl lye2:= 0.3099-IN 4 M nbl (Syel)-Fy= 13.788-I N-KI PS NOMINAL ALLOWABLE BENDING MOMENT Qb-M 0.975 OK < 1.0 Mnbl MODULOUS OF ELASTICITY REQUIRED: lyreq:= 0.0069 u)wl-Ll 4 – 0.353-IN 4 < lyel = 0.499-IN 4 OK Ll E.- 180 CHECK HEADER FOR WIND LOADING DESIGN: HEADER=> Sxe2 := 0.4463-Cl lxe2 := 0.9995-IN 4 MOMENT: ww:= (0.6-Pw).2.0-FT= 24.276-PLF UNIFORM LOAD ww.Ll 2 Mw:= — = 2.737-IN-KIPS MAXIMUM MOMENT 8 M nb2:= (Sxe2)-Fy= 24.547-I N-KI PS NOMINAL ALLOWABLE BENDING MOMENT Qb'Mw = 0.186 OK < 1.0 Mnb2 MODULOUS OF ELASTICITY REQUIRED: USE A CONTINUOUS'U'4 3/16"xYx I 6GA TOP TRACK WITH A'C'4"x2 1/2"x I 8GA 14EADER 5-ww-Ll 4 -81 -IN 4 < 4 OK lxreq:= — Ll Ixe2 1-IN 384-E-- 180 Page 25 CHECK DOORJAMB HEIGHT AND SPACING FOR 'C4"x21/2"xl8 GAUGE JAMBS. S,el := 0.4463-Cl SECTIONMODULUS W:= 6.. 16 126 MPH DESIGN Pw3:= 33.93-PSF-0.6 = 20.36-PSF WINDPRESSURE W-FT w3W:= Pw3 2 f=,,S,)xe 1 8W L3W L3W:= 13W:= — Fw3 12 13 12 LL w Lu 13W 0 9 81 7 6 8 10 12 14 16 w PIER SPACING, FT Page 26 CHECK DOOR JAMB HEIGHTAND SPACING FOR 'C'4"x2l/2"xl6 GAUGE JAMBS. S,e3:= 0.673-Cl SECTION MODULUS 126 MPH DESIGN Pw3= 20.36-PSF WINDPRESSURE xe�3T8W L5W L5W:= nb w3 15W:= 12 6 14 F- LL w m Lu 15W 12 m 0 8 6 8 10 12 14 16 w PIER SPACING, FT Page 27 MAKO STEEL, INC. STRUCTURAL CALCULATIONS BLTILDING'A' MATITCAD UNITS ARE... LB=- 1M IN =- 1L SI =- IN 2 CI =- IN 3 FT-- 12-IN SF =- FT 2 PCF=- LB KIPS -- 1000-LB FT 3 PSI -- LB PLF =- LB PSF LB KSI -- 1000. LB Fy:= 55-KSI E -- 29500-KSI IN 2 FT FT 2 IN 2 DESIGN LOADS: S := 25-PSF ROOF LIVE LOAD Dr:= 5-PSF ROOFDEADLOAD Dw:= 4-PSF EXTERIOR METAL WALL DEAD WIND LOADING @ 126 MPH,EXPOSURE C Ps30.A:= 30.49-PSF ZONEA Ps30.C:= 20.23-PSF ZONE C SEISMICFACTOR Cs:= 0.163 LFSW p:= 1.3 TRANSVERSE DESIGN Hl := 10.0-FT TOTAL HEIGHT OF BUILDING He:= 8.50-FT EAVE HEIGHT OF BUILDING Wl := 30.0-FT WTDTHOFBUTLDING Lj :� 130.-FT LENGTH OF BUILDING Tw:= 10.0-FT TYPICAL TRIBUTARY LOAD TO SHEAR WALLS T15:= 15.OFT TRIBUTARY LOAD TO SHEAR WALLS WIND DESIGN: LI)wA:= (Ps3C.A'0.6)-[-�e- , (Hl - He 105.2-PLF 2 He Lowc:= (Ps30.C-0.6)-[ 2 + (Hj - He 69.8-PLF GOVERNS SEISMIC DESIGN: He Eh:= (D,.Wl + 2-Dw. 2 )-CS-p-0.7 23-PLF WIND GOVERNS IN THE TRANSVERSE DIRECTION Page 28 CHECK SHEARWALLS: TYPICAL Ls,:= 30.0-FT LENGTH OF SHEARWALLS F,:= wC-T15= 1.047-KIPS FORCE AT EACH SHEARWALL F, V:= — = 35-PLF AT EACH ST-TEARWALL Ls, USE 29GA. 'U'-PANEL OR EQUALLY APPROVED SHEARWALLS WITH 'C' POSTS AT 6-ff'AND(6)#12 SCREWS TO EACH POST AND(1)#12 STITCH SCREW AT 20" OC, Vail = 90 PLF, SEE ATTACHED WALL TYPE 2 CHECK BASE SHEAR RESISTED BY EXPANSION Vl := v-5-FT= 0.174-KIPS REQUIRED SHEAR Val := 1.20-KIPS = 0.75 KIPS ALLOWABLE SI]EAR FOR HILTI KB-TZ 1.6 CHECK OVERTURNING He+ H, L50:= 10.0-FT CHECK WALL LENGTH H,:= — = 9.25-FT ROOF MEAN HEIGHT 2 M,,:= (v-L50)-H,= 3.228-FT-KIPS OVERTURNING MOMENT RESISTING MOMENT DUE TO DEAD LOAD L50 Mr:= (0.6-Dr).(L50-T,,).— = 1.5-FT-KIPS 1 2 Tl := Mo– Mr = 0.1173-KIPS REQUIRED TENSION PER ANCHOR L50 Tal := 0.940-KIPS = 0,588 KIPS ALLOWABLE TENSION 1.6 USE(1)1/2"�HILT[KB-TZ WITH A MINIMUM OF 2"EMBEDMENT AT 5'-0"OC,WITH SPECIAL INSPECTION. Page 29 LONGITUDINAL DESIGN:. WIND DESIGN: H, WwCL:= (Ps30.C'0-6,)' 2 ) = 56-PLF ZONEC SEISMIC DESIGN: UNIFORM SEISMIC LOAD Hm EhL:= D,11 + 2-Dw- CS-p-0.7= 85.6-PLF GOVERNS 1 2 SEISMIC GOVERNS IN THE LONGITUDINAL DIRECTION SITEARWALLS TRIBUTARYLOAD WIDTH TL:= Wl = 30-FT WORSE CASE CHECK EXTERIOR SHEARWALLS: FEL := EhL-TwL= 2.569-KIPS TOTAL SEISMIC LOAD FEL V3L:= — = 19.76-PLF ATEACH SHEARWALL Ll USE 26GA. MULTI-RIB SIDING PANEL SHEARWALLS WITH'C' POSTS AT 5'-6"AND(4)#12 SCREWS TO EACH POST AND(1)#12 STITCH SCREWAT 20"OC,Vall = 116 PLF, SEE ATTACHED WALL TYPE 13 CHECK BASE SHEAR RESISTED BY EXPANSION ANCHORS V3L:= V3L.5-FT= 0.099-KIPS REQUIRED SHEAR PER ANCHOR Val = 0.75-KIPS ALLOWABLE SHEAR FOR 14TLTI KWTK BOLT USE(1)1/2"CONCRETE ANCHOR AT EACH ROOF POST(5'-0"OC)WITH SHOTPINS AT 2 4"OC CHECK INTERIOR SHEAR WALL: USE 29GA. 'U'-PANEL SHEARWALLS WITH 'C' POSTS AT T-O", MAX PANEL SPAN IS 6'-0--AND(6)#12 SCREWS TO EACH POST AND (1)#12 STITCH SCREW AT 20" OC, Vall = 90 PLF, SEE ATTACHED WALL TYPE 2 CHECK BASE S14EAR RESISTED BY EXPANSION ANCHORS VIL:= V3L'10-FT= 0.198-KIPS REQUIRED SHEAR PER ANCHOR Val = 0.75-KIPS ALLOWABLE SHEAR FOR HILTI KWIK BOLT USE(1)1/2"CONCRETE ANCHORAT 10'-0"OC(AT EACH ROOF POSTS)WITH(2)SHOTPINS AT EACH VERTICAL GIRTS(5'-0"FROM ROOF POSTS) Page 30 CHECK 18GA METAL PIER SYSTEM: Rp:= 0.7EhL-TwL = 0.899-KIPS TOTALFORCE Np:= 30 NUMBER OF PIERS 2 Fp:,= 1p = 0.03-KIPS TOTAL FORCE AT THE TOP OF EACH PIER Np Mop:= Fp-He= 0.255-FT-KIPS OVERTURNING MOMENT Sp,,:= 5.8164-Cl EFFECTIVE SECTION MODULUS OF BUILT-UP METAL PIER SYSTEMS USING 26GA METAL PIER WRAP WITH'C'4"x2 1/2"x I 6GA JAMBS AT EACH END. 1.67-Mop ­ 0.018 < 1.00 OK Sp,e.50.KSI CIIECK26 GA.COVER SCREW ATTACHMENT TO DOOR JAMBS FP*He Tpier:� = 22.5-PLF SHEAR ALONG DOORJAMB S Vscre, 151-lb ALLOW.SHEAR#12, 16-IN-He 26 GA TO 16 GA SPACING1:= Vscrew = 36.6.IN MAXIMUM SPACING AT 36"OC Tpier USE#12 SCREWS AT 30"TO ATrACH 26 GA.PIER COVER TO JAMBS RESISTING MOMENT DUE TO DEAD LOAD Mrp:= 0.6.(3-PSF)-(T,,.H,.).8.IN= 0.102-FT-KIPS Tp:= MOP— Mrp — 0.141-KIPS REQUIRED TENSION 16-IN— 3-IN Va5'= 1.025-KIPS-0.7 = 0.718KIPS ALLOWABLE SHEAR Ta5:= 1.50-KIPS-0.7= 1.05KIPS ALLOWABLE TENSION USE(1)1/2�HILTI KB-TZ WITH A MINIMUM OF 3 1/4"EMBEDMENT AND A MINIMUM EDGE DISTANCE OF 3"AT EACH END OF PIER,(2)TOTAL PER PIER,SPECIAL INSPECTION REQUIRED. Page 31 CIFS Version 9.0.4 Page 1 Section: C4x16-METAL-PlER-SYSTEM.sct 4 x 2.5 C 16 Gage LGS1 Library 16" LONG METAL PIERS SYSTEM WITH Rev. Date: 3/20/2007 By: Michael Dale, P.E. 'C'4"x2 1/2"xl 6GA DOOR JAMBS & Printed: 8/16/2016 26GA METAL PIER WRAP ATTACHED TO JAMBS WITH #12 TEKS PER CALCS Section Inputs Material: A607 Class 2 Grade 55 No strength increase from cold work of forming. modulus of Elasticity, E 29500 ksi Yield Strength, Fy 55 ksi Tensile Strength, Fu 67.7 ksi Warping Constant Override,, Cw 0 in^6 Torsion Constant Override, J 0 �n^4 Connector Spacing 0 in C-Section, Thickness 0.059 in Placement of Part from Origin: X to center of gravity -7.0338 in Y to center of gravity 0 in Outside dimensions, Open shape Length Angle Radius Web k Hole Size Distance (in) (deg) (in) Coef. (in) (in) 1 0.7730 270.000 0.18750 None 0.000 0.0000 0.3865 2 2.5000 180.000 0.18750 Single 0.000 0.0000 1.2500 3 4.0000 90.000 0.18750 Cee 0.000 0.0000 2.0000 4 2.5000 0.000 0.18750 Single 0.000 0.0000 1.2500 5 0.7730 -90.000 0.18750 None 0.000 0.0000 0.3865 Part 3, Thickness 0.059 in Placement of Part from Origin: X to center of gravity 7.0338 in Y to center of gravity 0 in Outside dimensions, Open shape Length Angle Radius Web k Hole Size Distance (in) (deg) (in) Coef. (in) (in) 1 0.7730 90.000 0.18750 None 0.000 0.0000 0.3865 2 2.5000 360.000 0.18750 Single 0.000 0.0000 1.2500 3 4.0000 270.000 0.18750 Cee 0.000 0.0000 2.0000 4 2.5000 180.000 0.18750 Single 0.000 0.0000 1.2500 5 0.7730 90.000 0.18750 None 0.000 0.0000 0.3865 Page 32 CFS Version 9.0.4 Page 2 Section: C4x16-METAL-PlER-SYSTEM.sct 4 x 2.5 C 16 Gage LGSI Library Rev. Date: 3/20/2007 By: Michael Dale, P.E. Printed: 8/16/2016 Channel, Thickness 0.0176 in Placement of Part from Origin: X to center of gravity 0 in Y to center of gravity 1.3216 in Outside dimensions, Open shape Length Angle Radius WeID k Hole Size Distance (in) (deg) (in) Coef. (in) (in) 1 4.000 90.000 0.18750 Single 0.000 0.000 2.000 2 16.000 360.000 0.18750 Cee 0.000 0.000 8.000 3 4.000 270.000 0.18750 Single 0.000 0.000 2.000 Full Section Properties Area 1.5914 in^2 wt. 0.0054109 k/ft Width 43.671 in Tx 4.216 in^4 rx 1.6277 in Ixy 0.000 in^4 SX(t) 2.5519 in^3 Y(t) 1.6522 in a 90.000 deg Sx(b) 1.1/959 in^3 y(b) 2.3478 in Height 4 .0000 in Ty 73.848 in^4 ry 6.8120 in XQ 0.0000 in SY(l) 9.2310 in^3 X(l) 8.0000 in Yo 2.6395 in Sy(r) 9.2310 in^3 x(r) 8.0000 in jx 0.0000 in Width 16.0000 in jy -4 .5912 in Il 73.848 in^4 rl 6.8120 in 12 4.216 in^4 r2 1.6277 in IC 78.064 in^4 rc 7.0038 in Cw 30.160 in^6 To 89.151 in^4 ro 7.4846 in 1 0.0014039 in^4 Fully Braced Strength - 2010 North American Specification - US (ASID) 000--- ME---0=0-000-- Material Type: A607 Class 2 Grade 55, Fy=55 ksi Compression Positive Moment Positive Moment Pao 24.368 k Maxo 41.28 k-in Mayo 159.95 k-in Ae 0.88609 in^2 Txe 3.125 in^4 Tye 56.304 in^4 Sxe(t) 1.5010 in^3 Sye(l) 8.9092 in^3 Tension Sxe(b) 1. 6295 in^3 Sye(r) 5.6164 in^3 Ta 52.413 k Negative Moment Negative Moment Maxo 39. 92 k-in Mayo 159.95 k-in Shear Ixe 3. 664 in^4 Tye 56.304 in^4 Vay 7.940 k Sxe(t) 2.4817 in^3 Sye(l) 5.8164 in^3 Vax 9.800 k Sxe(b) 1.4517 in^3 Sye(r) 8.9092 in'3 Channel element 1 w/t exceeds 60. Channel element 2 w/t exceeds 200. Channel element 3 w/t exceeds 60. Page 33 ftYRIN A IM -VW MBCI 'U' & 'R' PANEL SHEAR WALLS MARK PANEL CAGE SPAN #12 TEKS TO #12 SIDELAP ALLOWABLE ALLOWABLE NO. (FEET) SUPPORTS SPAC'G (IN) WIND SEISMIC ..................... lul 29 5'-0" 6 12" 102 PLF 95 PLF 2 lul 29 5'-0" 6 20" 96 PLF 90 PLF Alul 26 5'-0" 6 12" 149 PLF 140 PLF 4 lul 26 5'-0" 6 20" 140 PLF 132 PLF lul 29 2'-6" 6 12" 196 PLF 184 PLF 5 6 U 29 2'-6" 6 20" 184 PLF 173 PLF lul 7 26 2'-6" 6 12" 287 PLF 270 PLF lul 26 2'-6" 6 20" 270 PLF 254 PLF R' 26 5'-0" 6 12" 206 PLF 194 PLF 'R' 26 5'-0" 6 20" 194 PLF 183 PLF 'R' 26 4'-0" 6 12" 189 PLF 201 PLF 'R' 26 4'-0" 6 20" 178 PLF 189 PLF MULTI— 26 5'-6" 4 20" 123 PLF 116 PLF �ARIB FU 1— 26 5'-0" 4 20" 164 PLF 154 PLF RLI'TB NOTES: 1. USE A MINIMUM 18GA (Fy=55KSI) FRAMING MEMBERS. 2. THE PANEL YEILD STRENGTH IS 80 KSI. 3. THE PANEL VALUES MAY BE DOUBLED IF ON BOTH SIDES. IF TWO DIFFERENT PANELS ARE USED, THE VALUE OF THE LOWEST STRENGTH PANEL MAY BE DOUBLED. Page 34 OVIMARIVIJM! Moi FASTENER TECHNICAL INFORMATION C) PULL OUT STRENGTH VALUES(POUNDS ULTIMATE) PLYWOOD OSB HARDISOFT WOOD 3/4" 5181, 1/2" 5181, 7116" SPRUCE FIR OAK PINE 7THISSREMAD WOO!7 R WOODSCREW 461 461 391 96 375 405 693 464 f#MB x PANCMEHEAD WOODSCREW 715 600 447 224 684 725 935 765 #10 x 1" WOODSGREW 584 540 183 710 825 1130 1170 #10 x 1"'I h" WOODSCREMW 578 439 430 212 710 780 1025 930 #14 x FASTENER STEEL S/ 1/4" 3/16" 10 GA 12 GA. 14 GA 16 CA 18GA 22GA PANCAKEHEAD DRILLER NA NA NA 1630 960 814 #10 x 1" _ALFOR111ING ---- SELF DRILLER NDWASHER CA 22 WrXMS;2, NA. NA 3BOO 1697 1151 687 435 8 �T. W/el 4 x 11/2ff SELF DRILLER 3450 3450 3450 1850 1134 770 484 301 #12-140".11/2" SELF OHILLER NA NA 2900 1850 1134 770 484 301 #12-14 x 11/4 1'/;, SELFOR100 STITCH INA NA NA NA NA NA 114X' OR DEKFAST metal sales NA NA NA NA NA NA .-uf9Cb&kM cowsoo, Corporme Otfice (812)246-11935 0 Metal Sales Manufactu6ng CorpowloTV Subjed to change Without notice/EffectW Data 6f99 www.mllsates.com Page 35 FASTENER TECHNICAL INFORMATION PULL OVER STRENGTH VALUES'(POUNDS ULTIMATE) SEAM-LOC 24 18 CA 20 CA 22 CA STEEL 24CA' 26 CA 29 CA TRUSS HEAD WOODSCREW SNAP-LOC 24 7r� NA NA NA 732 578 462 VERTICAL SEAM #8 x PANCAKE HEAD Fl--.j WOODSCREW PRO-LOC I 1900 1605 1335 985 742 602 PH O-LOC 11 #1 a 1" x WOODSCREW PRO-LOC III NA NA NA 790 658 477 MINI-BATrEN flux 11,11 L---------in WOODSCREW MAXI-BATTEN 3/16"Pre 3/16"Pre 3116"Pre 3/16"Pre 3/16"Pre I/8"Pre .2056 1613 1417 845 670 593 IMAGE 11 STEEL 114, 1 SOFf IT PANEL 18 CA 20 CA 22GA 24 CA 26 CA 29 CA PANCAKEHEAD r__ DRILLER '-SfILE 1900 1605 1335 985 742 575 #10 x 1* IC72-PANEL WoRums SE HILLER R-PANEL 2053 1770 1355 1020 682 524 #114-14 x 1112" U-PAWEL —3wmuma low SPAN-LINE 36 f]*W!m> 1645 1307 1138 787 673 541 #1 2;w14DxfL1 SPAN-LINE 36A SFE—LFORILLER TLINE 32 2030 1717 1525 1020 763 582 ........... PRO-PANEL 11 STITCH CLASSIC RIB NA 1567 1450 877 753 590 #14 5V CRIMP 11EKf T metalsaies ffwgdwwdv wm0fasm NA NA NA NA NA NA Corporm oft (612)246-19M www-musat".com 0 M"S6149 Martufactuft 0wWaWV SubJW to Mange wkhDA noUW EffecOm[We a Page 36 TABLE 2—ALLOWABLE TENSILE PULL-OUT LOADS(PNOTI.0),pounds-force"'�3,4.5 Steel F.-45 ksi Applied Factor of Safety,0=3.0 Screw Nominal Design thickness of member not in contact with the screw head(in.) Designation Diameter (in.) 0.036 0.048 0.060 0.075 0.090 D.105 0.135 #6-20 0.138 63 84 106 132 158 185 238 #8-18 0.164 75 100 125 157 188 220 282 #10-12,#10-16 1 0.190 87 116 145 182 218 254 327 #12-14,#12-24 0.216 99 165 207 1 132 248 289 373 0.2 153 191 239 287 333 '/4-14 0 115 4730 7] For SI:I inch=25.4 mm,1 lbf=4.4 N,I ksi 6.89 MPa, 'For tension connections,the lower of the allowable pull-out,pullover,and tension fastener strength of screw found in Tables 2,3,and 5, respectively must be used for design. 2ANSI/ASME standard screw diameters were used in the calculations and are listed in the tables. 3 The allowable pull-out capacity for other member thicknesses can be determined by interpolating within the table. 'To calculate LRFD values,multiply values in table by the ASID safety factor of 3.0 and multiply again with the LRFD 0 factor of 0.5. 5For F.�t 65 ksi steel,multiply values by 1.44. TABLE 3—ALLOWABLE TENSILE PULL-OVER LOADS(PNovM)o po un cis-force','-'-"' Steel F�=45 ksi Applied Factor of Safety,n=3.0 Washer or Design thickness of member in contact with the screw head(in.) Screw Head — Designation Diameter 0.030 0.036 0.048 0.060 0.075 0.090 0.105 0.135 (in.) I I I I I I I Hex Washer Head(HWH)or High Hex Washer Head(HHWH) #8_18 0.335 225 271 363 453 567 680 790 1020 #10-16 0.399 268 323 430 540 673 807 943 1210 #12-14,#12-24 0,415 279 337 447 560 700 840 980 1260 1/,-14 0.500 336 407 540 677 843 1010 1180 1520 Phillips Pan Head(PPH) #8_18 0.311 210 252 336 420 525 630 735 945 #10-16 0.364 246 295 393 491 614 737 860 1106 Phillips Truss Head(PTH) #8-18 0.433 292 351 1 468 1 565 731 877 1023 1315 Phillips Pan Framing Head(PPFH) #7-18 0.303 205 245 1 327 1 409 511 614 716 920 Phillips Pancake Head(PPCH) #10-16 0.409 276 331 1 442 1 552 690 828 966 1242 Phillips Flat Truss Head(PFTH) #10-12 0.364 246 295 393 491 614 737 860 1106 For SI:1 inch=25.4 mm, 1 lbf=4.4 N, 1 ksi=6.89 MPa. 'For tension connections,the lower of the allowable pull-out,pullover,and tension fastener strength of screw found in Tables 2,3,and 5, respectively must be used for design. 2ANSIIASME standard screw head diameters were used in the calculations and are listed in the tables. 3The allowable pull-over capacity for other member thicknesses can be determined by interpolating within the table. 4 To calculate LRFD values,multiply values In table by the ASD safety factor of 3.0 and multiply again with the LRFD(P factor of 0.5. 6For F.2 65 ksi steel,multiply values by 1.44. Page 37 TABLE 4-ALLOWABLE SHEAR(BEARING)CAPACITY OF SCREW CONNECTIONS OF COLD-FORMED STEEL,lb -2.3.4,5 Steel F.=45 ks! Applied Factor of Safety,C)=3.0 Design Nominal thickness of Design thickness of member not in contact with the screw head(in.) Screw Diameter member in Designation (in.) contact with screw head, 0.036 0.048 0,06D 0.075 0.090 0.105 0,135 (in.) 0.036 174 239 239 239 239 239 239 0.048 174 268 319 319 319 319 319 0.060 174 268 373 400 400 400 400 #8-18 0.164 0.075 174 268 373 497 497 497 497 0.090 174 268 373 497 597 597 597 0.105 174 268 373 497 597 697 697 0.135 174 268 373 497 597 697 897 0.036 188 277 277 277 277 277 277 0.048 188 289 370 370 370 370 370 #10-12 0.060 188 289 403 463 463 463 463 0.190 0.075 188 289 403 563 577 577 577 #10-16 0.090 188 289 403 563 693 693 693 0.105 188 289 403 563 693 807 807 0.135 188 289 403 563 693 807 1040 0.036 200 309 315 315 315 315 315 0.048 200 308 420 420 420 420 420 #12-14 0.060 200 308 430 523 523 523 523 0,216 0.075 200 308 430 600 657 657 657 #12-24 0.090 200 308 430 600 787 787 787 0.105 200 308 430 600 787 920 920 0.135 200 308 430 600 787 920 1180 0.036 215 340 363 363 363 363 363 0.048 215 331 467 487 487 487 487 0.060 215 331 463 607 607 607 607 114-14 0.250 0.075 215 331 463 647 760 760 760 0.090 215 331 463 647 850 910 910 0.105 215 331 463 647 850 1060 11060 0.135 215 331 463 647 850 1060 1370 For SI:1 inch 25.4 mm,1 lbf 4.4 N.1 ksi=6.89 IVIPa. 'The lower of the allowable shear(bearing)and the allowable fastener shear strength found in Tables 4 and 5,respectively must be used for design. 2ANSIIASME standard screw diameters were used in the calculations and are listed in the tables 'The allowable bearing capacity for other member thicknesses can be determined by interpolating within the table. 'To calculate LRFD values,multiply values in table by the ASD safety factor of 3.0 and multiply again with the LRFD 4)factor of 0.5. 'For F.�t 65 ksi steel,multiply values by 1.44. Page 38 TABLE 5—FASTENER STRENGTH OF SCREW NOMINAL FASTENER STRENGTH ALLOWABLE FASTENER STRENGTH' SCREW DIAMETER DETERMINED BY TESTING DESIGNATION (IN.) Tension,Pt, Shear,P. Tension(Pt,/Q)' Shear(P.J.0)2-3 (lb) (lb) (lb) (lb) #6-20 0.138 1000 890 335 295 #7-18 0.151 1000 890 335 295 #8-18 0.164 1000 1170 335 390 #10-12 0.190 2170 1645 720 550 #10-16 0.190 1370 1215 455 405 #12-14 0.216 2325 1880 775 625 #12-24 0.216 3900 2285 1300 760 '/,-14 1 0.250 4580 2440 1 1525 1 815 For SI: 1 inch=25.4 mm,1 lbf=4.4 N, 1 ksi 6.89 MPa. 'For tension connections,the lower of the allowable pull-out,pullover,and tension fastener strength of screw found in Tables 2,3.and 5, respectively must be used for design. 2For shear connections,the lower of the allowable shear(bearing)and the allowable fastener shear strength found in Tables 4 and 5, respectively must be used for design. 3 See Sections 4.1.3 and 8.4.1.3,as applicable,for fastener spacing and end distance requirements. To calculate LRFD values,multiply the nominal fastener strengths by the LRFD 0 factor of 0.5. ==Vn� FIGURE 1—HEX WASHER HEAD(HWH)AND HIGH FIGURE 2—PHILLIPS PAN HEAD(PPH)SCREW HEX WASHER HEAD(HHWH)SCREW FIGURE 3—PHILLIPS PAN FRAMING HEAD(PPFH)SCREW FIGURE 4—PHILLIPS BUGLE HEAD(PBH)SCREW FIGURE 5—PHILLIPS WAFER HEAD(PWH)SCREW Nam FIGURE 6—PHILLIPS PANCAKE HEAD(PPCH)SCREW FIGURE 7—PHILLIPS FLAT TRUSS HEAD(PFTH)SCREW Page 39 www.hilti.us Profis Anchor 2.4.6 Company: Page: 1 Specifier: Project: Address: Sub-Project I Pos.No.: Phone I Fax: Date: 4/11/2014 E-Mail. Specifier's comments: I Input data Anchor type and diameter: 1361CU^n'CS 112421l,� Effective embedment depth: 4�6,f ZOO in.,h,�m=2.375 in. Material: Carbon Steel Evaluation Service Report: ESR-1917 Issued I Valid: 5/1/2013 15/1/20115 Proof: design method ACI 318/AC193 Stand-off installation: -(Recommended plate thickness:not calculated) Profile: no profile Base material: crabk6d"b rete'2500 V,�:1500,' I; p�i h,' 4`0601ri, Reinforcement: tension:condition B,shear:condition B;no supplemental splitting reinforcement present edge reinforcement:none or<No.4 bar Seismic loads(cat.C,D.E,or F) no < WIND LOADING ONLY Geometry[in.]&Loading[lb,in.lb] ALLOWABLE TENSION Z Ta 1 . 55—k/1 . 6 0 . 968—k CF10 V9 Z M. 11-11;, 0101 NO Z. 4?pUg P�i U& .114--mnil— A', 1-M, �_T NO Ng,Frgr.q r ti, & IX� '16­_; ff; q MURE 914==4 _Ii; qg�4 ll,ll."'i - ft Kqi`M!t W 'Et. R X Page 40 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilti isa registered Trademark of Hilt!AG,Schaan www.hilti.us Profis Anchor 2.4.6 Company: Page: 2 Specifier: Project: Address: Sub-Project I Pos.No.: Phone I Fax: Date: 4/11/2014 E-Mail: 2 Load case/Resulting anchor forces Load case:Design loads Anchor reactions[lb] Tension force:(+Tension,-Compression) Anchor Tension force Shear force Shear force x Shear force y 1 1550 0 0 0 max.concrete compressive strain: N1 max.concrete compressive stress: [psi] resulting tension force in(x1y)=(0.000/0.000)-. 0[lb) resulting compression force in(x/y)=(0.000/0.000):0[lb] 3 Tension load Load N.,(I bl Capacity+Nn[lb] Utilization fW Nu./4Nn Status Steel Strength* 1550 8029 20 OK Pullout Sti N/A N/A N/A N/A Concrete Breakout Strength— 1550 1563 100 OK *anchor having the highest loading **anchor group(anchors in tension) 3.1 Steel Strength N,� ESR value refer to ICC-ES ESR-1 917 �Ni,t�l Nua ACI 318-08 Eq.(D-1) Variables n A..,,,[in.2] f.'.[psi] 1 0.10 106000 Calculations N,a 11b] 10705 Results N,a[1b] N�.[lb] Nu.[lb] 10705 0.750 8029 1550 Page 41 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchi c)2003-2009 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark ofi AG,Schaan www.hilti.us Profis Anchor 2.4.6 Company: Page: 3 Specifier: Project: Address: Sub-Project I Pos.No.: Phone I Fax. Date� 4/1112014 E-Mail: 3.2 Concrete Breakout Strength N, =(ANC)qled,N WC,N kPcp,N No ACI 318-08 Eq.(134) ANcO Ncb 2!Nua ACI 318-08 Eq.(D-1) AN, see ACI 318-08,Part D.5.2.1,Fig.RD.5.2.1(b) A,c, 9 h 2 ef ACI 318-08 Eq.(D-6) Yec,N 1 +.2 eN :5 1.0 ACI 318-08 Eq.(D-9) ( I he,) XJ11d,N�0.7+0.3 G'5h&)r.1.0 ACI 318-08 Eq.(D-1 1) Y�I.N =MAX(c.—,1N 5 1.0 ACI 318-08 Eq.(D-13) cac cac No =k. h.'j' ACI 318-08 Eq.(D-7) Variables her[in.] e.1,N[in.] eC2,N[in.) c.,.i,[in.] NIC,N 2.000 0,000 0.000 1.000 ca.[in.] kc ?� f.[psi] 5.500 17 1 2500 Calculations AN,(in 2] AWO[in.2] kllecl,N Yec2.N lVed N 41cp,N Nb[lb] 36.00 36.00 1.000 1.000 1.000 1.000 2404 Results N,b[lb] Oconcrete 0 Nc1b[lb] Nus[1b] 2404 0.650 1563 1550 Page 42 Input data and results must be checked for agreement with the existing con ditions and for plausibility! PROFIS Anchor(c)2003-2009 HIM AG,FL-9494 Schaan Hitt is a regstered Trademark ofHilti AG,Schaan www.hilti.us Profis Anchor 2.4.6 Company: Page: 4 Specifier: Project: Address: Sub-Project I Pos.No.: Phone I Fax: Date: 4/11/2014 E-Mail: 4 Shear load Load V..[lb] CaPaCitY#Vn[lb] Utilization flV Vua/�Vn Status Steel Strerl N/A N/A N/A N/A Steel failure(with lever arm)* N/A N/A N/A N/A Pryout Strength* N/A N/A N/A N/A Concrete edge failure in direction N/A N/A N/A N/A *anchor having the highest loading **anchor group(relevant anchors) 5 Warnings - To avoid failure of the anchor plate the required thickness ran be calculated in PROFIS Anchor.Load re-distributions on the anchors due to elastic deformations of the anchor plate are not considered.The anchor plate is assumed to be sufficiently stiff,in order not to be deformed when subjected to the loading! Condition A applies when supplementary reinforcement is used.The 0 factor is increased for non-steel Design Strengths except Pullout Strength and Pryout strength. Condition B applies when supplementary reinforcement is not used and for Pullout Strength and Pryout Strength.Refer to your local standard. Refer to the manufacturer's product literature for cleaning and installation instructions. Checking the transfer of loads into the base material and the shear resistance are required in accordance with ACI 318 or the relevant standard! Fastening meets the design criteria! Page 43 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilt!is a registered Trademark of Hilb AG,Schaan www.hilti.us Profis Anchor 2.4.6 Company: Page: 5 Specifier: Project: Address: Sub-Project I Pos.No.: Phone I Fax: Date. 4/11/2014 E-Mail: 6 Installation data Anchor plate,steel:- Anchor type and diameter:Kwik Bolt TZ-CS,112(2) Profile:- Installation torque:480.001 in.lb Hole diameter in the fixture:- Hole diameter in the base material:0.500 in. Plate thickness(input):- Hole depth in the base material:2.625 in. Recommended plate thickness:- Minimum thickness of the base material:4.000 in. Cleaning:Manual cleaning of the drilled hole according to instructions for use is required. Coordinates Anchor in. Anchor X y C.X C.x c_y C.y 1 0.000 0.000 7 Remarks; Your Cooperation Duties - Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles,formulas and security regulations in accordance with Hilti's technical directions and operating,mounting and assembly instructions,etc.,that must be strictly complied with by the user. All figures contained therein are average figures,and therefore use-specifle tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore.you bear the sole responsibility for the absence of errors,the completeness and the relevance of the data to be put in by you-Moreover,you bear sole responsibility for having the results of the calculation checked and cleared by an expert,particularly with regard to compliance with applicable norms and permits,prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors,the correctness and the relevance of the results or suitability for a specific application. You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular,you must arrange for the regular backup of programs and data and,if applicable,carry out the updates of the Software offered by Hilti on a regular basis.If you do not use the AutoUpdate function of the Software,you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences,such as the recovery of lost or damaged data or programs,arising from a culpable breach of duty by you. Page 44 Input data and results must be checked for agreement with the existing cord itions and for plausibility! PROFIS Archor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan www.hilti.us Profis Anchor 2.4.6 Company: Page: 1 Specifier: Project: Address: Sub-Project I Pos.No.: Phone I Fax: Date: 4/11/2014 E-Mail: Specifier's comments: I Input data Anchor type and diameter: Effective embedment depth: b 6 0_'J h hi, =-",2--3_7'_61h. Material: Carbon Steel Evaluation Service Report: ESR-1917 Issued I Valid: 511/2013 15/11/2015 Proof: design method ACI 318/AC193 Stand-off installation: -(Recommended plate thickness:not calculated) Profile: no profile -�:::I.......­�.......... ............ Base material: ;cra6k6dc6ncr9 Reinforcement: tension.condition B,shear:condition B;no supplemental splitting reinforcement present edge reinforcement.none or<No.4 bar Seismic loads(cat.C,D,E,or F) no '<���WIND LOADING ONLY Geometry[in.]&Loading[lb,in.1b] ALLOWABLE TENSION Z : Ta = 0. 940k/1 . 6 = 0 .587k ALLOWABLE SHEAR Va 1 .20K/1 . 6 0 . 75K gt CF10 M ...... 1-4. ,M, d MEN .......... ,,4�w. .:X,- 411:1 ...... ,—kik 0%;M. �r, N, IRRIN MviV OF N Z E', 1 V�,INI z"; X Page 45 lnputdataand results must be checked for agreement with the existing conditions and for plausibility! PROF I S Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilt!is a registered Trademark of HilU AG,Schaan www.hilti.us Profis Anchor 2.4.6 Company: Page: 2 Specifier: Project: Address: Sub-Project I Pos.No.: Phone I Fax: Date: 4/11/2014 E-Mail, 2 Load case/Resulting anchor forces Load case:Design loads Anchor reactions[lb) Tension force:(+Tension,-Compression) Anchor Tension force Shear force Shear force x Shear force y 1 940 1200 1200 0 max.concrete compressive strain: -1%.1 max.concrete compressive stress: -[psi] resulting tension force in(x/y)=(0.000/0.000): 0[lb] resulting compression force in(x/y)=(0.000/0.000):0[lb] 3 Tension load Load Nu.[lb] Capacity [lb] Utilization N Nua/4Nn Status Steel Strength* 940 8029 12 OK Pullout Strength* N/A N/A N/A N/A Concrete Breakout Streri 940 1563 61 OK *anchor having the highest loading —anchor group(anchors intension) 3.1 Steel Strength N�a ESR value refer to ICC-ES ESR-1 917 �Nteel Nue ACI 318-08 Eq.(D-1) Variables n A..,N[in.2] G.[psi] 1 0.10 106000 Calculations N_[lb] 10705 Results Nse[lb] llmeel N,a[lb] Nua(lb] 10705 0.750 8029 940 Page 46 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor(c)2003-2009 HIM AG,FL-9494 Schaan Hild is a registered Trademark of Hilti AG,Schasm www.hilti.us Profis Anchor 2.4.6 Company: Page: 3 Specifier: Project: Address: Sub-Project I Pos.No.: Phone I Fax: Date: 4/1112014 E-Mail: 3.2 Concrete Breakout Strength N, = (AN�)Yed,N IVC,N 41CP,N Nb ACI 318-08 Eq.(D-4) ANcO N,2:N,a ACI 318-08 Eq.(D-1) ANc see ACI 318-08,Part D.5.2.1.Fig.RD.5.2.1(b) ANI =9 h 2 ef ACI 318-08 Eq-(D-6) 1 Yet,,N = +2 e'N 51.0 ACI 318-08 Eq.(D-9) 3 h) =0.7+0.3 Cannin):5 1.0 ACI 318-08 Eq. (D-1 1) (1.5%, =MAX(SM!n, 1.0 ACI 318-08 Eq.(D-13) Cac Cac Nb =kC helf5 ACI 318-08 Eq.(D-7) Variables her[in] ec,,N[in.] e.2,14[in.] c.,.i,(in.] IIC,N 2.000 0.000 0.000 1.000 c.,[in.] kc k f c[psi] 5.500 17 1 2500 Calculations A,,,[in 2] ANCO[in.2] �VeclA 41..2,N kVad,N qJcp�N Nb[lb] 36.00 36.00 1.000 1.000 1.000 1.000 2404 Results N�b[1b] Ocorcrete NO[lb] Nu,i[lb] 2404 0.650 1563 940 Page 47 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilti isa registered Trademark ofHilti AG,Schaan www.hilti.us Profis Anchor 2.4.6 Company: Page: 4 Specifier: Project: Address: Sub-Project I Pos.No.: Phone I Fax: Date: 4/11/2014 E-Mail: 4 Shear load Load V..[lb] Capacity+V,[lb] Utilization pv V�J+V� Status Steel Strength* 1200 3572 34 OK Steel failure(with lever arm)* N/A N/A N/A N/A Pryout Strength— 1200 1683 72 OK Concrete edge failure in direction N/A N/A N/A N/A *anchor having the highest loading **anchor group(relevant anchors) 4.1 Steel Strength Vsa ESR value refer to ICC-ES ESR-1 917 0 Vsteel Vua ACI 318-08 Eq.(D-2) Variables n A..'v[in 2] f.'.[psi] 1 0.10 106000 Calculations V_[lb] 5495 Results V�.jib] �steel V�[lb] V�.[11b] 5495 0,650 3572 1200 4.2 Pryout Strength V-p =kcp ANc)%Ved,N YC,N YCPN Nb ACI 318-08 Eq.(C-30) AN.0 I VCp�Vu. ACI 318-08 Eq�(D-2) AN, see ACI 318-08,Part D.5.2-1,Fig.RO.5.2.1(b) AN, 9 h 2 of ACI 318-08 Eq.(D-6) 1 4 2 eN :5 1.0 ACI 318-08 Eq.(D-9) II)ec,N I ) ( 3 h& IVed.N=0.7+0.3(1'5h&)!5 1.0 ACI 318-08 E%(D-11) Iftp,N=MAX(cami�,1.5h.,):5 1.0 ACI 318-08 Eq.(D-13) cac Cac Nb =kc k �Fc h e1f5 ACI 318-08 Eq.(D-7) Variables k�, h.f[in.] ec,,N[in.] ec2,N[in.] ca,i�[in.) 1 2.000 0.000 0.000 qlc,N c.c[in.] k� fc[psi] 1.000 5.500 17 1 2500 Calculations ANc[in.2] ANO[in.2] Y_I.N Yec2,N XV�d,N 41W.N Nb[11b] 36.00 36.00 1.000 1.000 1.000 1.000 2404 Results V,[lb] �wrorete Vcp[lb] Vu.[lb] 2404 0,700 1683 1200 5 Combined tension and shear loads PN PV Utilization PN,V 1%] Status 0.602 0.713 5/3 100 OK PNV=P�+O�v<=1 Page 48 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilti iss registered Trademark otHilti AG,Schaan www.hilti.us Profis Anchor 2.4.6 Company: Page: 5 Specifier: Project: Address: Sub-Project I Pos.No.: Phone I Fax: Date: 4/11/2014 E-Mail: 6 Warnings - To avoid failure of the anchor plate the required thickness can be calculated in PROFIS Anchor.Load re-distributions on the anchors due to elastic deformations of the anchor plate are not considered.The anchor plate is assumed to be sufficiently stiff,in order not to be deformed when subjected to the loading! Condition A applies when supplementary reinforcement is used,The 0 factor is increased for non-steel Design Strengths except Pullout Strength and Pryout strength. Condition B applies when supplementary reinforcement is not used and for Pullout Strength and Pryout Strength.Refer to your local standard. Refer to the manufacturer's product literature for cleaning and installation instructions. Checking the transfer of loads into the base material and the shear resistance are required in accordance with ACI 318 or the relevant standard! Fastening meets the design criteria! Page 49 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark ofHilti AG,Schaan ------------_----------- www.hilti.us Profis Anchor 2.4.6 Company: Page: 6 Specifier: Project: Address: Sub-Project I Pos.No.: Phone I Fax: Date: 4/11/2014 E-Mail: 7 Installation data Anchor plate,steel:- Anchor type and diameter:Kwik Bolt TZ-CS,1/2(2) Profile:- Installation torque:480.001 in.lb Hole diameter in the fixture.- Hole diameter in the base material:0.500 in. Plate thickness(input):- Hole depth in the base material:2.625 in. Recommended plate thickness:- Minimum thickness of the base material:4.000 in. Cleaning:Manual cleaning of the drilled hole according to instructions for use is required. Coordinates Anchor in. Anchor X y C, C.x c_y C.y 1 0.000 0.000 8 Remarks; Your Cooperation Duties - Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles,formulas and security regulations in accordance with Hilti's technical directions and operating,mounting and assembly instructions,etc.,that must be strictly complied with by the user. All figures contained therein are average figures,and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore,you bear the sole responsibility for the absence of errors,the completeness and the relevance of the data to be put in by you-Moreover,you bear sole responsibility for having the results of the calculation checked and cleared by an expert,particularly with regard to compliance with applicable norms and permits,prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors,the correctness and the relevance of the results or suitability for a specific application. You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular,you must arrange for the regular backup of programs and data and,if applicable,carry out the updates of the Software offered by Hilti on a regular basis.If you do not use the AutoUpdate function of the Software,you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences,such as the recovery of lost or damaged data or programs,arising from a culpable breach of duty by you. Page 50 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hflti is a registered Trademark of Hilti AG,screen www.hilti.us Profis Anchor 2.5.2 Company: Page: 1 Specifier: Project Address: Sub-Project I Pos.No.: Phone I Fax: Date: 4116/2015 E-Mail: Specifieft comments: I Input data Anchor type and diameter: Kwik Bolt TZ-CS 1/2(2) Effective embedment depth: heract=2.000 in.,hinom=2.375 in. Material: Carbon Steel Evaluation Service Report: ESR-1917 Issued I Valid: 5/11/2013 15/1/2015 Proof: Design method ACI 318-111 Mech. Stand-off installation: -(Recommended plate thickness:not calculated) Profile: no profile Base material: cracked concrete,2500.fc'=2500 psi;In=4.000 in. Installation: hammer drilled hole, Installation condition.Dry Reinforcement: tension:condition B,shear.condition B,no supplemental splitting reinforcement present edge reinforcement:none or<No.4 bar Seismic loads i C,D,E,or F) Tension load:yes(D.3.3.4.3(d)) Shear load:yes(D.3.3.5.3 i Geometry[in.]&Loading[Ilb,ii SEISMIC GOVERNS Z ALLOWABLE TENSION Ta = 1.00—k*0. 7 0 .70—k ALLOWABLE SHEAR Fa 0 .70—k*0. 7 0 .490—k §t Ap M gf g "14 R3',� b"'I -4 �4... .—Man. \X Page 51 Input data and results must be checked for agreement with the existing conditions and for plausibility! Pi Ani c)2003-2009 1 AG,FL-9494 Schean Hilti isa registered Trademark ofi AG,Schaan www.hilti.us Profis Anchor 2.5.2 Company: Page: 2 Specifier: Project: Address: Sub-Project I Pos.No.: Phone I Fax: Date: 4/16/2015 E-Mail. 2 Load case/Resulting anchor forces Load case:Design loads Anchor reactions[lbl Tension force:(+Tension,-Compression) Anchor Tension force Shear force Shear force x Shear force y 1 1000 700 700 0 max.concrete compressive strain: -10/61 max.concrete compressive stress: -[psi] resulting tension force in(x/y)=(0.000/0.000): 0[lb] resulting compression force in(x/y)=(0.000/0.000):0[lb] 3 Tension load Load N.,[lb] Capacity fN,[lb] Utilization pN Nua/4Nn Status Steel Strei 1000 8029 13 OK Pullout Sti N/A N/A N/A NIA Concrete Breakout Strei 1000 1172 86 OK *anchor having the highest loading **anchor group(anchors intension) 3.1 Steel Strength Nsa ESR value refer to ICC-ES ESR-1 917 0 N�t_l N�a ACI 318-11 Table D.4.1.1 Variables n A..,N[in.2] G.[psi] 1 0.10 106000 Calculations N,a[lb] 10705 Results N,a[b] N�a[lb] Nua[lb] 10705 0.750 8029 1000 Page 52 Input data and results must be checked for agreement with the existing conditions and for plausibility! i Ani c)2003-2009 Hilt!AG,FL-9494 Schean Hilti is a registered Trademark ofHilti AG,Schaan wwi; Profis Anchor 2.5.2 Company: Page: 3 Specifier: Project: Address: Sub-Project I Pos.No.: Phone I Fax. Date: 4116/2015 E-Mail: 3.2 Concrete Breakout Strength N, =(ANO)Yed,N AVc,N 41cp,N N, ACI 318-11 Eq. (D-3) ANcO N,,b Z:N.. ACI 318-11 Table D.4.1.1 AN� see ACI 318-11,Part D.5.2.1,Fig.RD.5.2.1(b) A,, =9h 2 ef AC 1318-11 Eq.(D-5) 4)ec,N 1 +2 eN 15 1.0 ACI 318-11 Eq.(D-8) ( I hef) ii,]Jed.N =0.7+0.3 1.0 ACI 318-11 Eq.(D-10) 1.5hat =MAX c. ,.,1 5h,,f :5 1.0 ACI 318-11 Eq.(D-1 2) ( Cac Cac ) Nb =kc)..Nffc h.f' ACI 318-11 Eq.(D-6) Variables h.f[in.] ii[in.] ii[in.] c.,.i,[in.] YC,N 2.000 0,000 0.000 1.000 Cac[in.] k. f C[psi] 5.500 17 1.000 2500 Calculations AN,[in 2) ANi:0[in.2] Yet:1,N Yoc2.N IVed.N Yp,N Nb[lb] 36.00 36.00 1.000 1.000 1.000 1.000 2404 Results N,b[lb] 't,cancrete Oselsmc �norductife Ncb[lb] N�i,,[lb] 2404 0.650 0.750 1.000 1172 1000 Page 53 Input data and results must be checked for agreement with the existing conditions and for plausibility! i Anchi c)2003-2009 1 AG,FL-9494 Schaan i is a registered Trademark ofHilti AG,Schaan www.hilti.us Profis Anchor 2.5.2 Company: Page: 4 Specifier: Project: Address: Sub-Project I Pos.No.: Phone I Fax: Date: 4116/2015 E-Mail: 4 Shear load Load V.,[lb] Capacity*V,[lb] Utilization pv Vua/OVn Status Steel Strength* 700 3572 20 OK Steel failure(with lever arm)* N/A N/A NIA N/A Pryout Strength— 700 1683 42 OK Concrete edge failure in direction N/A N/A N/A N/A *anchor having the highest loading **anchor group(relevant anchors) 4.1 Steel Strength Vsa,eq =ESR value refer to ICC-ES ESR-1 917 �vsteel a V.. ACI 318-11 Table D.4.1.1 Variables n A_,,,[in.21 f.t.[psi] 1 0.10 106000 Calculations V�.,eq[lb] 5495 Results Vsa,eg[lb] �steel 0 V.(11b] Vua 11b] 5495 0,650 3572 700 4.2 Pryout Strength V-P =kcp[QNo)kVed,N kpc,N qicp,N Nb] ACI 318-11 Eq.(D-40) ANcO VcP�V�a ACI 318-11 Table D.4.1.1 ANC see ACI 318-11,Part D.5.2.1,Fig. RD.5.2.1(b) ANI 9 h 2 ef ACI 318-11 Eq.(D-5) 1+2 eN 5 1.0 ACI 318-11 Eq.(D-8) ki)e�,N ( 3 het IV.d.N 0.7+0.3(1 5hef)15 1.0 ACI 318-11 Eq.(D-10) ,1,5he 1.0 -11 Eq.(D-12) 4/cp,N MAX ft± Cac ACI 318 NI. k.�.;f:he'f' ACI 318-11 Eq.(D-6) Variables kcp hef[in.] e.1,N[in.] e.2,N[in,) c.,.i,[in.] 1 2.000 0.000 0,000 kVc,N Ca.[in.] k. �-a f [psi] 1.000 5.500 17 1,000 2500 Calculations AN,[in 2] ANcO[in.2] 4f—I,N Yec2.N kV.d,N' Yp.N Nb[lb] 36.00 36.00 1.000 1.000 1.000 1.000 2404 Results V,[lb] �wrcrete �seisrnic �rorductile V,[lb] V.a[lb] 2404 0.700 1.000 1.000 1683 700 5 Combined tension and shear loads N PV Utilization ON,V 1%) Status 0.853 0.416 5/3 100 OK 3NV +O�v Page 54 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan A www.hilti.us Profis Anchor 2.5.2 Company: Page: 5 Specifier: Project: Address: Sub-Project I Pos.No.: Phone I Fax. Date: 4/16/2015 E-Mail: 6 Warnings - Load re-distributions on the anchors due to elastic deformations of the anchor plate are not considered.The anchor plate is assumed to be sufficiently stiff,in order not to be deformed when subjected to the loading! Inputdata and results must be checked for agreement with the existing conditions and for plausibility! Condition A applies when supplementary reinforcement is used.The 0 factor is increased for non-steel Design Strengths except Pullout Strength and Pryout strength. Condition B applies when supplementary reinforcement is not used and for Pullout Strength and Pryout Strength.Refer to your local standard. Refer to the manufacturer's product literature for cleaning and installation instructions. Checking the transfer of loads into the base material and the shear resistance are required in accordance with ACI 318 or the relevant standard! An anchor design approach for structures assigned to Seismic Design Category C,D, E or F is given in ACI 318-11 Appendix 0,Part D.3.3.4.3(a)that requires the governing design strength of an anchor or group of anchors be limited by ductile steel failure.If this is NOT the case,the connection design(tension)shall satisfy the provisions of Part D.3.3.4.3(b),Part D.3.3.4.3(c),or Part D.3.3.4.3(d).The connection design(shear)shall satisfy the provisions of Part D.3.3.5.3(a),Part D.3.3.5.3(b),or Part D.3.3.5.3(c). Part D.3.3.4.3(b)/part D.3.3.5.3(a)requires that the attachment the anchors are connecting to the structure be designed to undergo ductile yielding at a load level corresponding to anchor forces no greater than the controlling design strength.Part D.3.3.4.3(c)/part D.3.3.5.3(b) waives the ductility requirements and requires that the anchors shall be designed for the maximum tension/shear that can be transmitted to the anchors by a non-yielding attachment.Part D.3.3.4.3(d)/part D.3.3.5.3(c)waives the ductility requirements and requires the design strength of the anchors to equal or exceed the maximum tension/shear obtained from design load combinations that include E,with E increased by g�o. Hilti post-installed anchors shall be installed in accordance with the Hilti Manufacturers Printed Installation Instructions(MPII).Reference ACI 318-11,Part D.9.1 Fastening meets the design criteria! Page 55 Input data and results must be checked foragreement with the existing conditions and for plausibility! PROR S Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG.Schaan www.hilti.us Profis Anchor 2.5.2 Company: Page: 6 Specifier: Project: Address: Sub-Project I Pos.No.: Phone I Fax. Date: 4/16/2015 E-Mail: 7 Installation data Anchor plate,steel:- Anchor type and diameter:Kwk,Bolt TZ-CS 112(2) Profile:- Installation torque:480.001 in.lb Hole diameter in the fixture:- Hole diameter in the base material:0.500 in. Plate thickness(input):- Hole depth in the base material:2,625 in. Recommended plate thickness:- Minimum thickness of the base material:4,000 in. Cleaning:Manual cleaning of the drilled hole according to instructions for use is required. Coordinates Anchor in. Anchor x y c_x c'x c_y C.y 1 0.000 U00 8 Remarks; Your Cooperation Duties - Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles,formulas and security regulations in accordance with Hilti's technical directions and operating,mounting and assembly instructions,etc.,that must be strictly complied with by the user. All figures contained therein are average figures,and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore.you bear the sole responsibility for the absence of errors,the completeness and the relevance of the data to be put in by you.Moreover,you bear sole responsibility for having the results of the calculation checked and cleared by an expert,particularly with regard to compliance with applicable norms and permits,prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors,the correctness and the relevance of the results or suitability for a specific application. - You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular,you must arrange for the regular backup of programs and data and,if applicable,carry out the updates of the Software offered by Hilti on a regular basis.If you do not use the AutoUpdate function of the Software,you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences,such as the recovery of lost or damaged data or programs,arising from a culpable breach of duty by you. Page 56 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of HIM AG,Schaan www.hilti.us Profis Anchor 2.4.8 Company: Page: 1 Specifier: Project: Address: Sub-Project I Pos.Ni Phone I Fax: Date: 7/3012014 E-Mail: Specifier's comments: I Input data we alifth Anchor type and diameter: Kwik Bolt TZ-CS 1/2(2) Effective embedment depth: hef,act=2.000 in.,hnom=2.375 in. Material: Carbon Steel Evaluation Service Report: ESR-1917 Issued I Valid: 5/11/2013 15/11/20115 Proof: design method ACI 318-11/Mech. Stand-off installation: -(Recommended plate thickness:not calculated) Profile: no profile Base material: cracked concrete,3000,fc'=3000 psi;In=4.500 in. Installation: hammer drilled hole,installation condition:dry Reinforcement: tension:condition B,shear.condition B,no supplemental splitting reinforcement present edge reinforcement:none or<No.4 bar Seismic loads(cat.C,D,E,or F) Tension load:yes(D.3.3.4.3(a)) Shear load:yes(D.3.3.5.3(c)) Geometry[in.]&Loading[lb,iri SEISMIC GOVERNS Z ALLOWABLE SHEAR Va 1, 800—LB*0. 7 1, 260—LB ot R9 'Ri RUM Z", J, 1=ga NO N Ix Page 57 Input data and results must be checked for agreement with the existing conditions,and for plausibility! PROFIS Anchi c)2003-2009 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schean www.hilti.us Profis Anchor 2.4.8 Company: Page: 2 Specifier: Project: Address: Sub-Project I Pos.No.: Phone I Fax: Date: 7130/2014 E-Mail: 2 Load case/Resulting anchor forces Load case:Design loads Anchor reactions[lb] Tension force:(+Tension,-Compression) Anchor Tension force Shear force Shear force x Shear force y 1 0 1800 1800 0 max.concrete compressive strain: -1%.3 max.concrete compressive stress: -(psi] resulting tension force in(xly)=(0.000/0.000): 0[11b] resulting compression force in(x/y)=(0.000/0.000):0 111b] 3 Tension load Load Nu.[lb] Capacity [lb] Utilization Nualf^ Status Steel Strength* N/A N/A N/A N/A Pullout Strength* N/A N/A N/A N/A Concrete Breakout Strength— N/A N/A N/A N/A *anchor having the highest loading **anchor group(anchors intension) Page 58 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan wwwAlltims Profis Anchor 2.4.8 Company: Page: 3 Specifier: Project: Address: Sub-Project I Pos.No.: Phone I Fax: Date: 7/3012014 E-Mail: 4 Shear load Load V,.[lb] Capacity#V,[lb] Utilization pv VuJ+V,,, Status Steel Strength* 1800 3572 51 OK Steel failure(with lever arm)* N/A N/A N/A N/A Pryout Strength— 1800 1844 98 OK Concrete edge failure in direction N/A N/A N/A N/A *anchor having the highest loading **anchor group(relevant anchors) 4.1 Steel Strength V,a,eq =ESR value refer to ICC-ES ESR-1 917 �Vsteel a Vua ACI 318-11 Table D.4.1.1 Variables n A_,v[in.2] f.ta[Psi] 1 0.10 106000 Calculations Vsa,e,[lb] 5495 Results VS.'e,[lb] keel V.[lb] V..[lb] 5495 0.650 3572 1800 4.2 Pryout Strength Vcp =k,[(_�No)kVed,N YC,N YCP,N Nb ACI 318-11 Eq.(D-40) ANCO I iti Vcp�Vua ACI 318-11 Table D.4.1.1 ANc see ACI 318-11,Part D.5.2.1,Fig.RD.5.2.11(b) ANI =9 h 2 ef ACI 318-11 Eq.(D-5) 1 Yec,N� (1-f 2 eN 5 1.0 ACI 318-11 Eq.(D-8) 3 he) Yed,N=0.7+0.3(1 5h,):5 1.0 ACI 318-11 Eq.(D-10) II)cp.N =MAX c,,,,, 1 5h ):-.1.0 ACI 318-11 Eq.(D-12) ( Cac ' Cac Nb =k. helf5 ACI 318-11 Eq.(D-6) Variables kcp h.f[in.] e.1,N[in.] ei�2,N[in.] c.,.i,(in,) 1 2.000 0.000 0.000 Yc,N c..[in.] k. 2La f.[psi] 1.000 5.500 17 1.000 3000 Calculations AN,[in.2] AN.1[in.2] Y_I'N Ye.2.N kVed.N 'Vep.N Nti[lb] 36.00 36.00 1.000 1.000 1.000 1.000 2634 Results V,[lb] Omnaete Oseismic tnonductile V,[lb] Vue[lb] 2634 0-700 1.000 1-000 1844 1800 Page 59 Inputclata and results must be checked foragreement with the existing conditions and for plausibility! PROFIS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark ofHilti AG,Schean www.hilti.us Profis Anchor 2.4.8 Company: Page: 4 Specifier: Project: Address: Sub-Project I Pos.No.: Phone I Fax: Date: 7/30/2014 E-Mail: 5 Warnings - Load re-distributions on the anchors due to elastic deformations of the anchor plate are not considered,The anchor plate is assumed to be sufficiently stiff,in order not to be deformed when subjected to the loading! Condition A applies when supplementary reinforcement is used.The 0 factor is increased for non-steel Design Strengths except Pullout Strength and Pryout strength. Condition B applies when supplementary reinforcement is not used and for Pullout Strength and Pryout Strength.Refer to your local standard. Refer to the manufacturer's product literature for cleaning and installation instructions. Checking the transfer of loads into the base material and the shear resistance are required in accordance with ACI 318 or the relevant standard! An anchor design approach for structures assigned to Seismic Design Category C,D, E or F is given in ACI 318-11 Appendix D,Part D.3.3.4.3(a)that requires the governing design strength of an anchor or group of anchors be limited by ductile steel failure.If this is NOT the case,the connection design(tension)shall satisfy the provisions of Part D.3.3.4.3(b),Part D.3.3.4.3(c),or Part D.3.3.4.3(d).The connection design(shear)shall satisfy the provisions of Part D.3.3.5.3(a),Part D.3.3.5.3(b),or Part D.3.3.5.3(c). Part D.3.3.4.3(b)/part D.3.3.5.3(a)requires that the attachment the anchors are connecting to the structure be designed to undergo ductile yielding at a load level corresponding to anchor forces no greater than the controlling design strength.Part D.3.3.4.3(c)/part D.3.3.5.3(b) waives the ductility requirements and requires that the anchors shall be designed for the maximum tension/shear that can be transmitted to the anchors by a non-yielding attachment.Part D3.3.4.3(d)/part D.3.3.5.3(c)waives the ductility requirements and requires the design strength of the anchors to equal or exceed the maximum tension/shear obtained from design load combinations that include E,with E increased by c)o. Hilti post-installed anchors shall be installed in accordance with the Hilti Manufacturers Printed Installation Instructions(Iii Reference ACI 318-11,Part D.9.1 Fastening meets the design criteria! Page 60 input data and results must be checked foragreement with the existing conditions and for plausibility! PROFIS Anchor(c)2003-2009 Hilli AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG.Schaan www.hilti.us Profis Anchor 2.4.8 Company: Page: 5 Specifier: Project: Address: Sub-Project I Pos.No.: Phone I Fax: Date: 7/30/2014 E-Mail: 6 Installation data Anchor plate,steel:- Anchor type and diameter: Kwik Bolt TZ-CS 1/2(2) Profile.- Installation torque:480.001 in.lb Hole diameter in the fixture.- Hole diameter in the base material:0.500 in. Plate thickness(input):- Hole depth in the base material:2.625 in. Recommended plate thickness:- Minimum thickness of the base material:4.000 in. Cleaning:Manual cleaning of the drilled hole according to instructions for use is required. Coordinates Anchor in. Anchor X y C.X c_y c+y 1 0.000 0.000 7 Remarks; Your Cooperation Duties - Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles.formulas and security regulations in accordance with Hilti's technical directions and operating,mounting and assembly instructions,etc.,that must be strictly compiled with by the user. All figures contained therein are average figures,and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore,you bear the sole responsibility for the absence of errors,the completeness and the relevance of the data to be put in by you.Moreover,you bear sole responsibility for having the results of the calculation checked and cleared by an expert,particularly with regard to compliance with applicable norms and permits,prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors,the correctness and the relevance of the results or suitability for a specific application. You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular,you must arrange for the regular backup of programs and data and,if applicable,carry out the updates of the Software offered by Hilti on a regular basis.If you do not use the AutoUpdate function of the Software,you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences,such as the recovery of lost or damaged data or programs,arising from a culpable breach of duty by you. Page 61 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilti isa registered Trademark ofHilti AG,Schaan www.hilti.us Profis Anchor 2.6.4 Company: Page: 1 Specifier: Project: Address: Sub-Project I Pos.No.: Phone I Fax: Date: 8/1612016 E-Mail: Specifier's comments: I Input data Anchor type and diameter: Kwik Bolt TZ-CS 1/2(3 1/4) Effective embedment depth: h,,,c,=3,250 in.,h,,,=3.625 in. Material: Carbon Steel Evaluation Service Report ESR-1917 Issued I Valid: 10/1/2015 15/112017 Proof: Design method ACI 318-11/Mech. Stand-off installation: -(Recommended plate thickness:not calculated) Profile: no profile Base material: cracked concrete,2500,fc'=2500 psi;h=12.000 in. Installation: hammer drilled hole,Installation condition:Dry Reinforcement: tension:condition B,shear:condition B,no supplemental splitting reinforcement present edge reinforcement:none or<No.4 bar Seismic loads(cat.C,D,E,or F) Tension load:yes(D-3.3.4.3(d)) Shear load:yes(D.3.3.5.3(c)) Geometry[in.]&Loading[lb,in.1b] SEISMIC GOVERNS Z ALLOWABLE TENSION Ta= 1.50-k*0.7 = 1.05-k ALLOWABLE SHEAR Va 1.025-k*0.7 = 0.717-k co 11-MUM Aft. a N111,1115,111 KI qv=_ ,R X Page 62 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilti isa registered Trademark ofHilUAG,Schean www.hilti.us Profis Anchor 2.6.4 Company: Page: 2 Specifier: Project: Address: Sub-Project I Pos.No.: Phone I Fax: Date. 8/16/2016 E-Mail: 2 Load case/Resulting anchor forces Load case:Design loads Anchor reactions[lb] Tension force:(+Tension,-Compression) Anchor Tension force Shear force Shear force x Shear force y 1 1500 1025 1025 0 max.concrete compressive strain: -P-] max.concrete compressive stress: -[psi] resulting tension force in(xty)=(0.000/0.000): 0[lb] resulting compression force in(x/y)=(0.000/0.000):0 fib] 3 Tension load Load N..[lbl Capacity [lb] Utilization fW Nua/4Nn Status Steel Strenbth* 1500 8029 19 OK Pullout Strength* 1500 2396 63 OK Concrete Breakout Strength- 1500 1735 87 OK *anchor having the highest loading **anchor group(anchors intension) 3.1 Steel Strength N�a =ESR value refer to ICC-ES ESR-1 917 4)Nsa 2�Nua ACI 318-11 Table D.4.1.1 Variables A��N[in.2] f.'.[psi] 0.10 106000 Calculations N,a[lb] 10705 Results N,a[lb] N�.[lb] Nu.[lb] 10705 0.750 1.000 8029 1500 3.2 Pullout Strength Np,250 ';0 refer to ICC-ES ESR-1 917 Npr� Xa��5 0 Np,'f� Nus ACI 318-11 Table D.4.1.1 Variables f.[psi] %. Np,2500[lb] 2500 1.000 4915 Calculations N;5-0:0 1.000 Results Npn I,[lb] 4iconcrete iliseismic �nonductile Nnn,[lb] N�s[lb] 4915 0,650 0.750 1.000 2396 1500 Page 63 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark ofHilti AG,Schaan www.hilti.us Profis Anchor 2.6.4 Company: Page: 3 Specifier: Project: Address: Sub-Project I Pos.No.: Phone I Fax: Date: 8/16/2016 E-Mail: 3.3 Concrete Breakout Strength N, =(ANC)kVed,N IVC,N 41CP,N Nb ACI 318-11 Eq.(D-3) AN.0 N,2:N�a ACI 318-11 Table D.4.1.1 AN, see ACI 318-11,Part D.5.2.1,Fig.RD.5.2.1(b) AN, =9h 2 el ACI 318-11 Eq.(D-5) Yec.N 1 +.2 eN :5 1.0 ACI 318-11 Eq.(D-8) ( 13 he,) 11red.N �0.7+0.3(Slm):s 1.0 ACI 318-11 Eq.(D-10) 1.5hel 'p,N =MAX(Samt,11��):5 1.0 ACI 318-11 Eq.(D-12) cac cac Nb =k.�,a;f:hef5 ACI 318-11 Eq.(D-6) Variables her[in.] ec1,N[iri e�2,N[in.] c.,.in[in.] qfc,N 3.250 0.000 0.000 3.000 1.000 c.,[in.) k. )�a ([psi] 6.000 17 1.000 2500 Calculations ANc[in 2] AWO[in_2] Tecl,N Yec2,N kVed,N WcpN Nb[lb] 76.78 95.06 1.000 1.000 0.885 1.000 4980 Results N,,b[lb] Owncrete Oseisrnic t0nonductile N,,t)[lb] N..[lb] 3558 0,650 0.750 1.000 1735 1500 Page 64 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilt!AG,Schaan www.hilti.us Profis Anchor 2.6.4 Company: Page: 4 Specifier: Project: Address: Sub-Project I Pos.No.: Phone I Fax: Date: 8/1612016 E-Mail: 4 Shear load Load V..[Ib] Capacity+V,[lb] Utilization pv Vug/#Vn Status Steel Strength* 1025 3572 29 OK Steel failure(with lever arm)* N/A N/A N/A N/A Pryout Strength— 1025 4982 21 OK Concrete edge failure in direction y+** 1025 2618 40 OK *anchor having the highest loading **anchor group(relevant anchors) 4.1 Steel Strength Vsa,eq ESR value refer to ICC-ES ESR-1 917 Vua vsteel I ACI 318-11 Table D.4.1.1 Variables A.,,,,[in.21 f.t.[psi] 0.10 106000 Calculations Vsa.e,[lb] 5495 Results V..,.q[Ibl �steei 'Ononductile V..[lb] V.a[lb] 5495 0.650 1.000 3572 1025 4.2 Pryout Strength V-p =kcp[(_�Nc)IVed,N qfc,N kpcp,N No ACI 318-11 Eq.(D-40) ANCO I V,�Vua ACI 318-11 Table DA.1.1 AN, see ACI 318-11,Part D.5.2.1,Fig.RD.5.2.1(b) AW =9 h 2 at ACI 318-11 Eq.(D-5) kl)ec,N � 1+2 eN :5 1.0 ACI 318-11 Eq. (D-8) ( 13 he,) Ilred.14=0.7+0.3(1'5hef):5 1.0 ACI 318-11 Eq�(D-10) kl)cp,N=MAX(I.,-,n I 5h Ys 1.0 ACI 318-11 Eq.(D-12) Cac ' Cac Nb =kc�. ,ff:h'.5 ef ACI 318-11 Eq.(D-6) Variables kcp h&[in.] ec,,N[in.] ec2,N[in.] C.,min[in.] 2 3.250 0.000 0.000 3.000 Y��N ca,[in.] kc �-a fc[psi] 1.000 6.000 17 1.000 2500 Calculations AN.[in.2] ANcO[in.21 41ecl,14 Wec2,N kVed,N Tcp,N Nb[lb) 76.78 95.06 1.000 1.000 0.885 1.000 4980 Results V,jib] Ocorcrete Oseismic IfInonductile V,[lb] V.a[lb] 7117 0.700 1.000 1.000 4982 1025 Page 65 Inputdata and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark ofHilti AG,Schaan www.hilti.us Profis Anchor 2.6.4 Company: Page: 5 Specifier: Project: Address: Sub-Project I Pos.No.: Phone I Fax. Date: 8/1612016 E-Mail: 4.3 Concrete edge failure in direction y+ V, =(Avc) Av.0 kVed,V Yc,V 41h,V 41parallel,V V, ACI 318-11 Eq.(D-30) V�b a V.3 ACI 318-11 Table D.4.1.1 Avc see ACI 318-11,Part D.6.2.1,Fig,RD.6.2.1(b) Avco =4.5 C2 al ACI 318-11 Eq.(D-32) Yec,V� + 2 e'. :5 1.0 ACI 318-11 Eq.(D-36) 3Cal) 111�d,V=0.7+0.3 C E2_ :5 1.0 ACI 318-11 Eq.(D-38) (T-5aca I 1.5c�l t0h,V =4E5�cai 2:1.0 ACI 318-11 Eq.(D-39) ha cl 5 Vb =(7 �_d.) �fc at ACI 318-11 Eq.(D-33) da Variables cal[in.] C.2[in.] ecv[in.] YC'v h.[in.] 3.000 0.000 1.000 12.000 1.[in.] ?,a da[in.] fc[psi] Yparallel,V 3.250 1.000 0.500 2500 2.000 Calculations Avc[in.] Avco(in.2] kPec'v kVedV Wh,V Vb[lb] 40.50 40.50 1.000 1.000 1.000 1870 Results Vo[lb] �wncrete �seismic +n.nciuctile VCb(I b] V..[lb] 3740 0.700 1.000 1.000 2618 1025 5 Combined tension and shear loads PN PV Utilization ON,V 1%] Status 0.865 0.392 513 100 OK 13NV=P�+13�<= 6 Warnings - Load re-distributions on the anchors due to elastic deformations of the anchor plate are not considered.The anchor plate is assumed to be sufficiently stiff,in order not to be deformed when subjected to the loadingl Input data and results must be checked for agreement with the existing conditions and for plausibility! Condition A applies when supplementary reinforcement is used.The(P factor is increased for non-steel Design Strengths except Pullout Strength and Pryout strength. Condition B applies when supplementary reinforcement is not used and for Pullout Strength and Pryout Strength.Refer to your local standard. Refer to the manufacturers product literature for cleaning and installation instructions. Checking the transfer of loads into the base material and the shear resistance are required in accordance with ACI 318 or the relevant standardl An anchor design approach for structures assigned to Seismic Design Category C,D, E or F is given in ACI 318-11 Appendix D,Part D.3.3.4.3(a)that requires the governing design strength of an anchor or group of anchors be limited by ductile steel failure.If this is NOT the case,the connection design(tension)shall satisfy the provisions of Part D.3.3.4.3(b),Part D.3.3.4.3(c),or Part D.3.3.4.3(d).The connection design(shear)shall satisfy the provisions of Part D.3.3.5.3(a),Part D.3.3.5.3(b),or Part D.3.3.5.3(c). Part D.3.3.4.3(b)/part D.3.3.5.3(a)require the attachment the anchors are connecting to the structure be designed to undergo ductile yielding at a load level corresponding to anchor forces no greater than the controlling design strength.Part D.3.3.4.3(c)/part D.3.3.5.3(b) waive the ductility requirements and require the anchors to be designed for the maximum tension/shear that can be transmitted to the anchors by a non-yielding attachment.Part D.3.3.4.3(d) part D.3.3.5.3(c)waive the ductility requirements and require the design strength of the anchors to equal or exceed the maximum tension shear obtained from design load combinations that include E,with E increased by no- Hilti post-installed anchors shall be installed in accordance with the Hilti Manufacturers Printed Installation Instructions(MPII).Reference ACI 318-11,Part D.9.1 Page 66 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROMS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilti isa registered Trademark otHiltiAG,Schaan wwwhiltims Profis Anchor 2.6.4 Company: Page: 6 Specifier: Project: Address: Sub-Project I Pos.No.: Phone I Fax: Date: 8/1612016 E-Mail: Fastening meets the design criteria! Pa-ge 67 Input data and results must be checked for agreement with the existing Conditions and for plausibility! PROFIS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilti Ise registered TradeMarkDfHilti AG,Schaan www.hilti.us Profis Anchor 2.6.4 Company: Page: 7 Specifier: Project: Address: Sub-Project I Pos.No.: Phone I Fax. Date: 811612016 E-Mail: 7 Installation data Anchor plate,steel,- Anchor type and diameter: Kwik Bolt TZ-CS 1/2(3 1/4) Profile:- Installation torque:480.001 in.lb Hole diameter in the fixture:- Hole diameter in the base material:0.500 in. Plate thickness(input):- Hole depth in the base material:4.000 in. Recommended plate thickness:- Minimum thickness of the base material:8.000 in. Drilling method:Hammer drilled Cleaning:Manual cleaning of the drilled hole according to instructions for use is required. 7.1 Recommended accessories Drilling Cleaning Setting Suitable Rotary Hammer - Manual blow-out pump Torque wrench Properly sized drill bit Hammer Coordinates Anchor in. Anchor X y c.x C+x c_V C.y 1 0.000 0.000 3.000 8 Remarks; Your Cooperation Duties - Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles,formulas and security regulations in accordance with Hilti's technical directions and operating,mounting and assembly instructions,etc.,that must be strictly complied with by the user. All figures contained therein are average figures,and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore,you bear the sole responsibility for the absence of errors.the completeness and the relevance of the data to be put in by you.Moreover,you bear sole responsibility for having the results of the calculation checked and cleared by an expert,particularly with regard to compliance with applicable norms and permits,prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors,the correctness and the relevance of the results or suitability for a specific application. You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular,you must arrange for the regular backup of programs and data and,if applicable,carry out the updates of the Software offered by Hilti on a regular basis.If you do not use the AutoUpdate function of the Software,you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website, Hilti will not be liable for consequences,such as the recovery of lost or damaged data or programs,arising from a culpable breach of duty by you. Page 68 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilti Ise registered Trademark ofHiltiAG,Schaan