Loading...
HomeMy WebLinkAbout3713 Mount Angeles Road Address: 3713 Mount Angeles Road PREPARED 3/07/16, 12:42:13 INSPECTION TICKET PAGE 6 CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 3/07/16 ------------------------------------------------------------------------------------------------ ADDRESS . : 3713 MT ANGELES RD SUBDIV: CONTRACTOR : PHONE OWNER Maureen Sandison PHONE PARCEL 06-30-14-3-1-9110-0000- APPL NUMBER: 16-00000252 RES MECHANICAL PERMIT ------------------------------------------------------------------------------------------------ PERMIT: ME 00 MECHANICAL PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS --------------------- ----------------------------------:---------------------------------- L MECHANICAL FINAL ME99 01 3/07/16 March 7, 2016 9:43:49 AM jlierly. nKaren 457-4508 ---- ----------- COMMENTS AND NOTES -------------------------------------- CITY OF PORT ANGELES oo DEPARTMENT OF COMMUNITY& ECONOMIC DEVELOPMENT- BUILDING DIVISION 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Application Number . . . . . 16-00000252 Date 2/24/16 Application pin number . . . 143616 Property Address . . . . . . 3713 MT ANGELES RD ASSESSOR PARCEL NUMBER: 06-30-14-3-1-9110-0000- REPORTSALES TAX Application type description RES MECHANICAL PERMIT on your state excise tax'form Subdivision Name . . . . . . Property Use . . . . . . . . RESIDENTAL SF 9000 to the City of Port Angeles Property Zoning . . . . . . . RS9 RESDNTL SINGLE FAMILY Application valuation . . . . 6829 (Location CodeV502) , ---------------------------------------------------------------------------- y Application desc REPLACEMENT OF OUTDOOR HEAT PUMP UNIT ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ Maureen Sandison OWNER 3713 Mt. Angeles PORT ANGELES WA 98362 — -----------------------------------L------------------------------------------- Permit . . . . . . MECHANICAL PERMIT Additional desc . . Permit Fee . . . . 64.80 Plan Check Fee .00 Issue Date . . . . 2/24/16 Valuation . . . . 0 Expiration Date . . 8/22/16 Qty Unit Charge Per Extension BASE FEE 50.00 1.00 14.8000 EA ME-FURN/HP/FAU < OR = 5 TON 14.80 ---------------------------------------------------------------------------- Special Notes and Comments Per Washington State Code 51-51-315, installation of Carbon Monoxide detector(s) is required if you are installing or replacing a fuel burning appliance (wood, pellet, gas)and must be in place prior to the final inspection of this permit. They are required to be place directly outside of each sleeping area and at least one on each floor of the house. ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- -------7-- ---------- Permit Fee Total 64.80 64.80 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 64.80 64.8Q .00 .00 06 Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced, or if required inspections have not been requested within ISO days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All.provisions 6f laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does' not presume to give authority to violate or cancel the provisions of an state or local law regulating construction or the performance of construction. Date Print Name Signature��Coynacto 0 Authorized Agent Signature of Owner(if owner is builder) T:Forms/Building Division/Building Permit BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS- Building Inspections 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backfiow Prevention Inspections 417-4886 IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION: Footings Stemwall Foundation Drainage I Downspouts Piers Post Holes(Pole Bldgs.) PLUMBING: Under Floor/Slab Rough-in Water Line(Meter to Bldg) Gas Line Back Flow/Water AIR SEAL: Walls Ceiling FRAMING: Joists/Girders/Under Floor Shear Wall/Hold Downs Walls/Roof/Ceiling Drywall(interior Braced Panel Only) T-Bar INSULATION: Slab Wall/Floor/Ceiling MECHANICAL: Heat Pump/Furnace/FAU/Ducts Rough-In Gas Line Wood Stove/Pellet/Chimney Commercial Hood/Ducts MANUFACTURED HOMES: Footing/Slab Blocking&Hold Downs jSkirting PLANNING DEPT. Separate Permit#s SEPA: Parking/Lighting ESA: Landscaping SHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY1 USE Inspection Type Date Accepted By Electrical 417-4735 Construction -R.W. PW I Engineering 417-4831 Fire 417-4653 Planning 417-4750 1 Building 417-4815 02/22/2016 06:26 13604525177 ALL WEATHER HEATING PAGE 01/03 TmF- For City Use CITY OFr -Cy-6-�' Permit# W A S H I N G T 0 N, U. S. Date Received; 3 2 1 E Sth Street Date Approved '7- 5z— 1 0 Port Angeles,WA 9836 P,360-417-4817 F.360-417-4711 Email.permitUM-0.1yDivam BUILDING PERMIT APPLICATION Project Address:3713 Mt. Angeles Road Pbone:360-457-4508 Primag Contact:Maureen Sandison Eynail: N.vne Maureen Sandison Pharw 360-457-4508 Property MaMing Addreu Eman Owner city 3713 Mt. Angeles Rd State Port Angeles WA 7"P 98362 Name All Weather Heating & Cooling, Inc. Phone 360-452-9813 Contractor Addre"302 Kemp Street Email billing@allweatherhc.com Information c-ity Port Angeles StatewA 71P 98362 ContractorLicen9c4ALLVVEHC150KU J Exp.Date-9116 Legal Description: Zoning: Tax Parcel# Project Value: (materiab;and labor) 1 1 J $ 6829.20 Residential 10 Commercial 11 Industrial 1:1 Public 0 Permit Demolition 11 Fire El Repair 0 Reroof(teat off/lay over) El Classification For the falla3ldng.B11 out both pages-of permit anglicatiom: (check New Construction 0 Exterior Remodel 13 Addition 0 Teriant Improvement L3 OPPr"Pr"'t') Mechanical 9 Plumbing El Other 0 F orExisdiog? Yes 13 No sed I Irrigatio —�Posed Bathroom osed Bedrooms ire Sprinkler Systern Propo n System Proposed o 13 Existing? Yes 0 No 0 In addition to standard hard copy submittalsPlease send a PDF copy of 41.1 Stormwater plans and Engineering to NNE.Stormwaterp-c"9&a.us Project Descri]etion Dked replacemnt of outdoor heat pump uinilt, Diked moacement of outdoor heat pump udlL Is project in a Flood Zone: Yes El No13 Flood Zone Type: If in a Flood Zone, what is the value of the structure before proposed improvement? $ 1 have read and completed the application and know it to be true and correct. I am authorized to apply for this permit and understand that it is my responsibility to determine what permits are required and to obtain permits prior to work. I understand that plan review fees are not reftindable after review has occurred. Uunderstand that I will.forfeit review fees if T withdraw the application before the permit is issued. I understand that if the permit is not picked up/issued within.x8o days of submittal,the application will be considered abandoned and the fees will.be forfeited. Karen McKeown Date Print Name �:tgnature Address: ount Angeles Road '9,-713 m� , �-Vpl PREPARED 7/31/15, 9:31:37 INSPECTION TICKET PAGE 7 CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 7/31/15 ------------------------------------------------------------------------------------------------ ADDRESS . ; 3713 MT ANGELES RD SUBDIV: CONTRACTOR POWER TRIP ENERGY CORP PHONE (360) 643-3080 OWNER CORN JOE B PHONE PARCEL 06-30-14-3-1-9110-0000- APPL NUMBER: 15-00000701 RES SOLAR PROJECT ------------------------------------------------------------------------------------------------ PERMIT: BSOL 00 BUILDING PERMIT - SOLAR REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ BL99 01 7/31/15 L�JLA BLDG FINAL July 30, 2015 1:04:38 PM jlierly. 360-643-3080 BOBBIE -------------------------------------- ------------------- ---------- COMMENTS AND NOTES CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT- BUILDING DIVISION 321 EAST 5TH STREET, PORT ANGELES,WA 98362 N Application Number . . . . . 15-00000701 Date 6/18/15 Application pin number . . . 402644 Property Address . . . . . . 3713 MT ANGELES RD ASSESSOR PARCEL NUMBER: 06-30-14-3-1-9110-0000- REPORT SALES TAX Application type description RES SOLAR PROJECT on your state excise tax form Subdivision Name . . . . . . Property Use . . . . . . . . RESIDENTAL SF 9000 to the City of Port Angeles Property Zoning . . . . . . . RS9 RESDNTL SINGLE FAMILY (Location Code 0502) Application valuation . . . . 17975 ---------------------------------------------------------------------------- - Application desc RESIDENTIAL ROOF MOUNTS SOLAR ARRAY ----------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ CORN JOE B POWER TRIP ENERGY CORP 1317 E 7TH ST 83 DENNY AVE PORT ANGELES WA 983626605 PORT TOWNSEND WA 98368 (360) 643-3080 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT - SOLAR Additional desc . . RES SOLAR GRID TIE ROOF MOUNTE Permit Fee . . . . 130.00 Plan Check Fee .00 Issue Date . . . . 6/18/15 Valuation . . . . 17975 Expiration Date . . 12/15/15 Qty Unit Charge Per Extension BASE FEE 130.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ------ --- ----- ------ ------ --- --- Permit Fee Total 130.00 130.00 00 00 Plan Check Total .00 .00 .00 .00 Grand Total 130.00 130.00 .00 .00 Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the-same to-be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. -�� 11�etpAo Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder) T:Forms/Building Division/Building Permit BUILDING PERMIT INSPECTION RECORD — PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS— Building Inspections 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION: Footings Stemwall Foundation Drainage/Downspouts Piers Post Holes(Pole Bldgs.) PLUMBING: Under Floor/Slab Rough-in Water Line(Meter to Bldg) Gas Line Back Flow/Water FINAL Date Accepted by AIR SEAL: Walls Ceiling FRAMING: Joists/Girders/Under Floor Shear Wall/Hold Downs Walls/Roof/Ceiling Drywall(interior Braced Panel Only) T-Bar INSULATION: Slab Wall/Floor/Ceiling MECHANICAL: Heat Pump/Furnace/FAU/Ducts Rough-In Gas Line Wood Stove/Pellet/Chimney Commercial Hood/Ducts FINAL Date Accepted by MANUFACTURED HOMES: Vooting/Slab 113locking&Hold Downs ISkirting PLANNING DEPT. Separate Permit#s SEPA: Parking/Lighting ESA: Landscaping ISHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY1 USE Inspection Type Date Accepted By Electrical 417-4735 Construction- R.W. PW I Engineering 417-4831 Fire 417-4653 Planning 417-4750 L Building 417-4815 T:Forms/Building Division/Building Permit CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY &ECONOMIC DEVELOPMENT-BUILDING DIVISION 321 FAST 5TH STREET, PORT ANGELES,WA 98362 Application Number . . . . . 15-00000701 Date 6/18/15 Application pin number . . . 402644 Property Address . . . . . . 3713 MT ANGELES RD ASSESSOR PARCEL NUMBER: 06-30-14-3-1-9110-0000- REPORT SALES TAX Application type description RES SOLAR PROJECT Subdivision Name . . . . . . on your state excise tax form Property Use . . . . . . . . RESIDENTAL SF 9000 to the City of Port Angel es Property Zoning . . . . . . . RS9 RESDNTL SINGLE FAMILY Application valuation . . . . 17975 (Location Code 0502) ---------------------------------------------------------------------------- Application desc RESIDENTIAL ROOF MOUNTS SOLAR ARRAY ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ CORN JOE B POWER TRIP ENERGY CORP 1317 E 7TH ST 83 DENNY AVE PORT ANGELES WA 983626605 PORT TOWNSEND WA 98368 (360) 643-3080 ------------------------------------------------------7--------------------- Permit . . . . . . BUILDING PERMIT - SOLAR Additional desc . . RES SOLAR GRID TIE ROOF MOUNTE Permit Fee . . . . 130.00 Plan Check Fee .00 Issue Date . . . . 6/18/15 Valuation 17975 Expiration Date . . 12/15/15- Qty Unit Charge Per Extension BASE FEE 130.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 130,00 130.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 130.00 130.00 .00 .00 U�v /1 Ao� 6 Lj Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements.This permit becomes null and void ifwork or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced,or if required Inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Date Print Name Signaturl Contractor or Qrized Agent Signature of Owner(if owner Is builder) T:Forms/Building Division/Building Permit 'ORT For City Use 3 THE -r F i CfTY 0 1- ;' LES -J.16- Permit# W A SH INGTO. N. U. S. Date Received: 321 E 51b Street Date Approved 6�Y-�q- Port Angeles,WA 9836 P:360-417-4817 F:360-417-4711 Email:permitsocilyo BUILDING PERMIT APPLICATION Project Ad&ess: Aakwr AN4-c-,�tF5 70vie�--TP-1p E"ep-49 C-e- Phon e: 3 0 9 0 ro Fk--c IT) 36 o q,3 Lb PrimaryContact- -,T0Kf-1 FLEt-w4cy �Email: '40W-1 a Nam�r C M44�EE�J SAqb1,<,0,q Phone -34�o-45'[ 450�b Property Mailin Address Email -7 - C&M Owner -;;. m.r." City F6 p- State WA- Zip q?36 7- Name Phon PCIV13 0R-Tlu P E14 eA-&l co, '(S(�0) Contractor Address Email — Information Put-," AAE . -46hm city 'FoA:.- T-cwmse�-t4b State Wk zip 9 BSI;2, Contractors license# ?0W1FkTE 9-34aff Exp.Date: ti Legal Description: Zoning: Tax Parcel#67jV,--10 Project VaJue: (materials and labor) $ Residential Commercial ff Industrial Public Permit Demolition 0 Fire 0 Repair 11 Reroof(tear off/lay over) Classification For the following,fill out both pages of permit allplication: (check New Construction El Exterior Remodel El Addition 0 Tenant improvement 0 appropriate) -L Mechanical 1:1 Plumbing 0 Other n Fire Sprinkler System? Irrigation System? Proposed Bathrooms Proposed Bedrooms Yes 13 No 5L Yes 13 No S Project Description Accr- 6ipub�-Tie- b P V Is project in a Flood Zone: Yes 13 NoIM Flood Zone Type: If in a Flood Zone, what is the value of the structure before proposed improvement? $ I have 'read and completed the application and know it to be true and correct.I am authorized to apply for this permit and understand that it is my responsibility to determine what permits are required and to obtain permits prior to work. I understand that plan review fees are not refundable after review has occurred. I understand that I will forfeit review fees if I withdraw the application before the permit is issued. I understand that if the permit is not picked up/issued within i8o days of submittal,the application will be considered abandoned and the fees will be forfeited. Date Print Name Signi .. , No Rec'd HTE Apprv'd $130 Fee Application and Checklist for Roof Mounted Residential Solar Panels Project Information: Property Owner Name: Joe Corn&Maureen Sandison Project Address: 3713 S. Mt.Angeles Rd, PA Phone:360-457-4508 Contractor Name: Power Trip Energy Co Registration#: POWERTE934QE Contractor Phone: 360-643-3080 PV system Roof mounted grid tied 6.05 kW Mfg/model#of major equip:SolarWorld description: 22.modules,6 kW inverter 275 watt Protect PV modules,SMA 6000TIL- US-22 inverter Per WAC 51-51-2300,if the answer to the following cluestions is"yes"a building permit will be issued for simple(10-lSkw output) PV systems without further engineering. Section M2302.2.1—Where solar panels are installed on roofs,the roof structure shall be deemed adequate to support the load of the rooftop if all of the following are met: Yes No 1. PV system is designed and proposed for a single family or detached accessory structure El 2. The photovoltaic panels and modules and supporting structure shall be constructed of noncombustible materials or fire-retardant treated wood equivalent to that required for the roof construction. The installation shall meet the requirements of the International Fire Code as amended by WA State. PV modules are listed and labeled with a fire classification in accordance with UL 1703 3. The PV system is designed for the wind speed of the local area and will be installed per the manufacturer's specifications. 4. The ground snow load does not exceed 70 pounds per square foot.The PV system is designed for the wind speed of the local area,and will be installed per the manufacturer's specifications. 5. Total dead load of modules,supports,mountings,raceways and all other appurtenances weigh El no more than four pounds per square foot. Enter total dead load of system (IbS/ft). [3.00 PSF 6. Supports for solar modules are installed to spread the dead load across as many roof-framing members as needed to ensure that no point load exceeds fifty(50) pounds. Modulesare mounted no higher than 18"above the surface of the roofing to which they are affixed and do not exceed the highest point of the roof unless approved by the local jurisdiction. NOTE: If site inspection indicates a concern that the roof structure is not adequate to support the PV modulle(s), engilne6ring may be required prior to final of the permit. As the property owner or authorized representative of the above listed property, I attest that all information in this checklist is accurate to the Oest of my knowledge. Applicant Signature: Date: 6/17/2015 Applicant Name(Please Print)- Lj)hn S. Fleming,Power Trip Energy Co Relationship to Property Owner: Installation Contractor T:\BUILDING\APPLICATION FORMS\SOLAR PERMIT CHECKLIST.DOCX Rook Rd City of PA Litility net Rook Rd meter on pedestal NORTH South Mt Angeles Rd New PV array 1;FDII0CF:'C'---z:�. P Service panels inside -VI west wall of garage JOE- COLARIr" MAUREENSolar production metej� AC disconnect on west e rior wall L'I' M M-06", Sunmodule;.,/ Protect SOLARWORLD, SW275 MONO REALVALUE L TILIV Power controlled: Lowest measuring tolerance in industry Every component is tested to meet 3 times IEC requirements Designed to withstand heavy accumulations of snow and ice Sunmodule Protect: Positive performance tolerance 30-year linear performance warranty and 10-year product warranty Glass with anti-reflective coating World-class quality Fully-automated production lines and seamless monitoring of the process and material ensure the q ua I ity that t he com pany sets a s its ben&ma rk fo r its s ites worldwide. Innovative glass technologies make extremely weather-resistant and robust solar modules POS- sible.The Sunmodule Protect offers higher mechanical resilience and a longer Service life,and still weighs the same as the Sunmodule Plus. C CW1 S The positive power tolerance guarantees utmost system efficiency.Only modules achieving or UL 1703 exceeding the designated nominal power in performance tests are dispatched.The power toler- ance ranges between-0 Wp and+5 Wp. � 7 ! SolarWorld is setting new standards with the ground-breaking 30-year linear performance guar- antee:a maximum degradation of just 0.35%p.a.provides guaranteed module performance of 90%after 21 years,and 86.85%after 30 years.' 30-year linear performance guarantee Linear performance guarantee for SolarWorld Sunmodule Protect Linear performance guarantee for SolarWorld Sunmodule Plus Competitor's tiered performance guarantee 0% !'A 3E 0% 1 5 10 is 20 25 30 Ycars 'in accordance with the applicable SolarWorld Limited Warranty at purchase. NIELM— www.solarworld,com/warranty MADE IN USA OF US solarworld.com A.413 WAPORTED PARTS Sunmodule;/ Protect SW275 MONO 64-11 REALVALUE PERFORMANCE UNDER STANDARD TEST CONDITIONS(STC)' PERFORMANCE AT 800 W/M',NOCT,AM 1.5 Maximumpower p- 275 Wp Maximum power p— 205.0 Wp Open circuit voltage V__ 39.4 V Open circuit voltage V� 36.1 V Maximum powerpoint voltage V—P 31.0 V Maximum power point voltage V11- 28.4 V Short circuit current 9.58 A Short circuit current ll� 7.75 A Maximum power point current 8.94 A Maximum power point current 1�pp 7.22 A Module efficiency 16.40% Minorreduction in efficiency under pdrtial luad cLfiditiorisat25*C:at200%,V/M2,100% (+/-2%)of the STC efficiency(1000 W/m�)is achreved- *STC:1000 W/ml.25'C,AM 1.5 1)Measuring tolerance(P,,,)traceable to TUV Rheinland:t/-2%(TUV Power Controlled), COMPONENT MATERIALS THERMAL CHARACTERISTICS Cells per module 60 NOCT 46*C Cell type Monocrystalline TC 1, 0.04%1-C Celldimensions 6.14 in x 6.14 in(156 rnm x 156 mm) TC V., -0,30%/'C Front Heat treated(EN 6121S) Tic P, -0.41%/�C Frame Clear anodized aluminum Operating temperature -40*C to 85*C weight 46.7 1 bs(21.2 kg) :C-mm S .5 k-4 v*j SYSTEM INTEGRATION PARAMETERS 1000 WJM2 Maximum system voltage SC I//NEC 1000V Maximum reverse current 16 A 800 W/m. Number of bypass diodes 3 ____600W/rn1____ Design Loads* -a rail system 113 psf downwar 64 psf upward V �A 3 ,rd ird Design Loads* Threerailsystem 170psfdownward 400 Wlmz 71 psf u pwa rd 0 Design Loads* Edge mounting 30 psf downward 200 W/ml 30 psf upward 100 W/m2 Please referto the Sunmodulemstalla'tion instructions'or the details associated with these load cases Module voltage M V_ ADDITIONAL DATA Powersorting' -0 Wp/+5 Wp -L-x 4 37�44(951) J-Box IP65 Module leads PV wire per UL4703 with H4 connectors T Module type(UL 1703) 3 11.33(288) Glass Low iron tempered with ARC 39.37(100 VERSION 2.S FRAME Version Compatible with both"Top-Down" and"Bottom"mounting methods 2.5frame 65.94(1675) bottom 4Grounding Locations: mounting 4comers of the frame holes 4 locations along the length of the L module in the extended flanget =L-x4 4.20(107)t 39.41(1001) U2(31) All units provided are imperial-Sl units provided in parenthese5_ SolarWorld AG reserves the right to make specification changes without notice, SW-01-6045US 08-2014 Friday,Janum-y 31,2014 Sna �rack- SnapNrack o r m a n 775 Fiero Lane,Suite 200 San Luis Obispo,CA 93401 Scheel "Series 100 Roof Mount" Cover Letter To Whom It May Concern, We have performed calculations for the 100 series roof mount PV system based on Structural the information provided by SnapNrack. Included with this letter are the report and calculations. We did the calculations in accordance with the 2012 IBC, ASCE 7-10, 2112 NDS, and guidelines stated in the Solar America Board for Codes arid En g i n e e r Standards. Some of the components in the SnapNrack test data were used to determine the 5022 Sunrise Blvd. capacity and section properties of materials. We collected the test data using the Fair Oaks,CA 95628 procedures outlined in the 2012 IBC Chapter 17. (916)536-9585 (916)536-0260(fax) We included the following types of load combinations and building parameters into our calculations: 1989-2013 24 years of e.rcellence ASCE 7-10 wind speeds from 110 mph to 190 for B and C exposure categories ASCE 7-10 Seismic Design Category E ASCE 7-10 Snow Loads up to 120 psf ground snow 0 Buildings with mean roof heights up to 60 foot tilt angles / roof pitches Norman Scheel,S.E. from 0 degrees to 60 degrees. LEED AP BD+C LEED AP Homes The calculations have also been completed in accordance with the 2006 IBC,2009 Fellow—SEAOC IBC, and ASCE 7-05. To use the data contained in this packet for projects that are .Fellow-ASCE E-mail:norm(i-Ossexo being evaluated to the older ASCE 7-05 wind speeds,refer to Appendix A for a Rob Coon wind speed conversion chart. Find the ASCE 7-05 (IBC 2006/2009)wind speed in General Manager the Chart in Appendix A,identify the corresponding ASCE 7-10(IBC 2012)wind r-mail:Tobcoon(a?nsse.co speed value,and proceed with using the charts contained in this packet with the Steve Smith P.E. adjusted wind speed value. Project Manager E-mail:stevesmith(a-Insse.com In our opinion, the mounting system, outlined by SnapNrack Series 100 PV Mounting System Code Compliance Installation Manual, is acceptable and meets Steven Cooksey the loading requirements as stated above. See the report and calculations included CAD Supervisor E-mail:stevcnamsse.co with this letter for more information. Jaclde Winslow If there are any further questions,please contact Norm Scheel. J. SO, Orfice Manager E-mail;iockicCalnssc-com Norman Scheel PE, SE LEED-AP BD+C,LEED-AP Homes Fellow Sji%kOC Fellow 1A.C.E. EXPIRES DECEMBER 26, L.02 !?J SnapNrack Series 100 Snap rack- ProjectInfo: Dealerd Power Trip Energy Co Project Name:1 Joe Corn,Maureen Sandison,Phq Create Date:1 2015-06-17Tl6:04:17-0700 BOM#:1 33857 PV Module Data: Module Brand SolarWorld Length 65.94 inches Model SW275mono Width 39.41 inches Depth 1.22 inches Environmental Requirements: Weight 46.70 pounds Topographic Condition Standard 71 Rated power @ STC 27500 W Standard IBC 2012 1 Rail Color Snow Load 21-30 psf — ITE Racking Color Wind Speed 130 mph — ITSK 'A CH6e-K&:1'*T Rafter Spacing 24 inches Roof Attachment Flashed L-Foot System Style: Rail Finish Black Anodized End Clamp Type Adjustable Grounding Method UL 2703 Listed Micro Attachment Kits No Edge Screen Trim?, No if"Yes",4"or 8"screen? Screen Height inches Tilt Up?[ No Sub-Arrays: I UL2703 Yes Premium Alloy Ra—i—IF­No Bulk Customer No Sub-Array Sub-Array 122" Rail 162" Rail Rail Mid End Edge Roof Modules Splices Clamps Clamps Screen Attachments 1 22 12 2 6 36 16 0 44 TOTALS] 22 12 2 6 16 16 0 44 Page I of 3 Corn-Sandison Solar Racking SnapNrack Series 100 Calculator Proposed Bill of Materials Part Number Description Qty 015-09822 SNAPNRACK,STANDARD RAIL SET,1221N,BLACK,6 PC 2 015-09818 SNAPNRACK,STANDARD RAIL SET,1621N,BLACK,2 PC 1 242-04015 SNAPNRACK,BONDING STANDARD RAIL SPLICE ASSEMBLY,BLACK 6 242-02050 SNAPNRACK,BONDING MID CLAMP ASSEMBLY,1.20-1.48IN,CLEAR 36 242-02065 SNAPNRACK,BONDING ADJUSTABLE X-END CLAMP ASSEMBLY,1.20-1.481N,CLEAR 16 232-01023 SNAPNRACK RAIL END CAP,STANDARD, BLACK 16 242-02700 SNAPNRACK,BONDING L-FOOT KIT W/BASE AND FLASHING,CLEAR L-FOOT 44 242-02101 SNAPNRACK,GROUNDING LUG ASSEMBLY 4 Total'Weight: 1SI.84 lbs �-System Total Weight: 1240.00 lbs jArray Area=22 modules x(40.4"x 67"/144 sq.inch per sf)=414 sf jPounds per Square Foot of Array=1240 lbs/414 sf=3.00 psf Item 5 checklist jPounds per attachment=1240 lbs/44=28.2 lbs per attachm ent Item 6 checklist Page 2 of 3 Modules Per 7 Array Pitch(degrees) 0 Sub-Array Modules 22 Row Nodule 4 Building Height(ft) 0 Edge Screen(ft) 0 Rows Orientation Portrait Attachment Spacing 72 Attachment Spacing 48 Array Power(kW) 6.05 (inches) Override(inches) The maximum recommended rail span for this sub-array is 72 inches.The rail span for modules located in edge zones is reduced by 24 inches to 48 inches Group I Rail Group 2 Rail Group 3 Rail Group 4 Rail Group 5 Rail 122"Rail 162"Rail Row Mid Row End Row Attach- Module Rail Length Length Length Length Length Qtv City Clamps Clamps Solices ments Bonding Bonding 241.46 4 0 10 4 2 12 0 1 241.46 4 0 10 4 2 12 0 1 241.46 4 0 10 4 2 12 0 1 161.64 0 2 6 4 0 8 0 1 EIFIDDE101:1 Sub-Array 12 2 36 16 6 44 0 4 Totals Corn-Sandison Solar Racking Page 3 of 3