Loading...
HomeMy WebLinkAbout526 E. 10th Street Address: olh Street PREPARED 9/11/15, 9:5 6:4 6 INSPECTION TICKET 'PAGE 4 CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 9/11/15 ------------------------------------------------------------------------------------------------ ADDRESS . : 526 E 10TH ST SUBDIV: CONTRACTOR POWER TRIP ENERGY CORP PHONE (360) 643-3080 OWNER NICKOLAUS JANET MARIE PHONE PARCEL 06-30-00-0-3-3210-0000- APPL NUMBER: 15-00000859 RES SOLAR PROJECT ------------------------------------------------------------------------------------------------ PERMIT: BSOL 00 BUILDING PERMIT - SOLAR REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ BL99 01 9/11/15 JM BLDG FINAL S eptember 11, 201S 9:57:08 AM jlierly. Bobbie 360-640-0380 --------------------------n--------- COMMENTS AND NOTES -------------------------------------- CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY &ECONOMIC DEVELOPMENT- BUILDING DIVISION 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Application Number . . . . . 15-00000859 Date 7/15/15 W Application pin number . . . 860752 Property Address . . . . . . 526 E 10TH ST ASSESSOR PARCEL NUMBER: 06-30-00-0-3-3210-0000- REPORT SALES TAX Application type description RES SOLAR PROJECT Subdivision Name . . . . . . on your state excise tax form Property Use . . . . . . . . to the City of Port Angeles Property Zoning . . . . . . . RS7 RESDNTL SINGLE FAMILY. Application valuation . . . . 17894 (Location Code 0502) ---------------------------------------------------------------------------- - Application desc ROOF MOUNTED GRID TIED SOLAR ARRAY ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ NICKOLAUS JANET MARIE POWER TRIP ENERGY CORP 526 EAST 10TH STREET 83 DENNY AVE PORT ANGELES WA 98362 PORT TOWNSEND WA 98368 (360) 643-3080 ----------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT - SOLAR Additional desc . . ROOF MOUNTED SOLAR ARRAY Permit Fee . . . . 130.00 Plan Check Fee .00 Issue Date . . . 7/15/15 Valuation . . . . 17894 -Expiration Date 1/11/16 Qty Unit Charge Per Extension BASE FEE 130.00 .00 14.0000 THOU BL-2001-25K (14 PER K) .00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 130.00 130.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 130.00 130.00 .00 .00 U Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit doe� not presume to give authority to violate or cancel.the provisions of any state or local law regulating construction or the performance of construction. Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder) T:Fornns/Building Division/B ui[ding Pernift BUILDING PERMIT INSPECTION RECORD — PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS— Building Inspections 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION: Footings Stemwall Foundation Drainage I Downspouts Piers Post Holes(Pole Bldgs.) PLUMBING: Under Floor/Slab Rough-in Water Line(Meter to Bldg) Gas Line Back Flow/Water FINAL Date Accepted bV AIR SEAL: Walls Ceiling FRAMING: Joists I Girders/Under Floor Shear Wall/Hold Downs Walls I Roof/Ceiling Drywall(Int�rior Braced Panel Only) T-Bar INSULATION: Slab Wall/Floor/Ceiling MECHANICAL: Heat Pump/Furnace/FAU/Ducts Rough-In Gas Line Wood Stove/Pellet I Chimney Commercial Hood/Ducts FINAL Date Accepted by MANU ACTURED HOMES: Footing/Slab Blocking&Hold Downs Skirting PLANNING DEPT. Separate Permit#s SEPA: Parking/Lighting ESA: Landscaping ISHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY1 USE Inspection Type Date Accepted By Electrical 417-4735 Construction- R.W. PW I Engineering 417-4831 Fire 417-4653 Planning 417-4750 Building 417-4815 T-Fnrm�/Riiilrfir niviqinn/Riflh1ir Pprmit CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY&ECONOMIC DEVELOPMENT- BUILDING DIVISION 321 EAST 5TH STREET, PORT ANGELES,WA 98362 Application Number . . . . . 15-00000859 Date 7/15/15 Application pin number . . . 8G0752 Property Address . . . . . . 526 E 10TH ST ASSESSOR PARCEL NUMBER: 06-30-00-0-3-3210-0000- REPORT SALES TAX Application type description RES SOLAR PROJECT Subdivision Name . . . . . . on your state excise tax form Property Use . . . . . . . . to the City of Port Angeles Property Zoning . . . . . . . RS7 RESDNTL SINGLE FAMILY Application valuation . . . . 17894 (Location Code 0502) ---------------------------------------------------------------------------- Application desc ROOF MOUNTED GRID TIED SOLAR ARRAY ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ NICKOLAUS JANET MARIE POWER TRIP ENERGY CORP 526 EAST 10TH STREET 83 DENNY AVE PORT ANGELES WA 98362 PORT TowNSEND WA 98368 (360) 643-3080 ----------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT - SOLAR Additional desc ROOF MOUNTED SOLAR ARRAY Permit Fee . . . . 130.00 Plan Check Fee Issue Date . . . . 7/15/15 valuation . . . . 17894 Expiration Date . . 1/11/16 Qty Unit Charge Per Extension BASE FEE 130,00 .00 14.0000 THOU BL-2001-25K (14 PER K) .00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 130.00 130.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 130.00 130.00 .00 .00 Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes nul I and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced,or if required inspections have not been requested within 180 days from the last Inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. �VT16.1-1v I�? s flo W E�P—­rp-1 N OR41 Co- Date Print Name Signature of Contractor or Authorized Agep Signature of Owner(if owner is builder) T:Forms/Building Divilsion/Building Permit -�IIRTL4 Permit# THE For City Use CITY OF] NGELES WASH I NGTOM. U. S. Date Received: 321 E Sth Street Date Approved Port.Angeles,WA 9836 P:360-417-4817 F:360-417-4711 Email:Rermits0dJXof9axs BUILDING PERMIT.APPLICATION ProjectAddress: to-t-l" F6 PT A N 6,E L E�-S, i F) T0WEf--TP-tP E"eA49 C-e>- Phone: 3 Go-64 S-3�oZo(oFkct 3,60 PrimaryContact: -TC-W-3 FLffM06c Email: I-OKO P— Nam!T�t4e-r A"ic- NtC-K0L-"5 Phone Property MailingAddress 57�46 CA-5T- 10T( ,5Z71 Email-TAf4ETMMN @ME7.6oM Owner city -Fo g.-r A P Ci F-i-C-S State WA- 7- Name Phon Few o�—1 ki ek&l cc T--,, (,a) 15�q 0 Contractor Address Email — , Information 9,-5, DE�w-,,q A-,4c- -1-011M (f, pewe;kr-kip F-Ne,*4-y,CCM -ciq To-R:—% T-awtAse7M> State Vv/t zip 11 bs�ls Contractors License# FOO&P-TE 9340,15 Exp.Date: -1 $ Legal Description: Zoning: Tax Parcel#06 WOO Project Value:(materials and labor) PIS+ 33Z-t06(300 17t i�'l 4 Residential Commercial Industrial 13 Public 13 Permit Demolition 0 Fire 11 Re-pair 0 Reroof(tear off/layover) Classification For the Lollowing.fill out both DaM of ennit ajaplication: (check New Construction 1:1 Exterior Remodel 11 Addition 13 Tenant Improvement appropriate) , Mec anical 13 Plumbing 13 Other 0 Fire Sprinkler System? Irrigation System? Proposed Bathrooms Proposed Bedrooms Yes C3 No 0L I Yes 13 No M I -� O/A-— I — Project Description P\/ orCV4-Mic-, -5LL-4 Lpi, E LE-if rpu e.� Is project in a Flood Zone: Yes 0 NoW Flood Zone Type: If in a Flood Zone,what is the value of the structure before proposed improvement? $ I have 'read and completed the application and know it to be true and correct.I am authorized to apply for this permit and understand that it is my responsibility to determine what permits are required and to obtain permits prior to work. I understand that plan review fees are not reftindable after review has occurred. I understand that I will forfeit review fees if I withdraw the application before the permit is issued. I understand that if the permit is not picked up/issued within i8o days of submitta.1,the application will be considered abandoned and the fees will be forfeited. Date Print Name S� Redd HTE Apprv'd $130 Fee Application and Checklist for Roof Mounted Residential Solar Panels Project Information: Property Owner Name: Janet Nickolaus Project Address: 526 East 10th St, Port Angeles,WA Phone:360-513-1013 Contractor Name: Power Trip Energy Co Registration#:POWERTE934QE Contractor Phone: 360-643-3080 PV system Roof mounted grid tied 6.3 kW Mfg/model#of major equip:SolarWorld description: 20 modules,7.7 kW inverter 315 watt Pro XL PV modules,SIVIA Sunny Boy 770OTL-US-22 inverter Per WAC 51-51-2300,if the answer to the following questions is"yes"a building permit will be issued for simple(10-15kw output)PV systems without further engineering. Section M2302.2.1—Where solar panels are installed on roofs,the roof structure shall be deemed adequate to support the load of the rooftop if all of the following are met: Yes No 1. PV system is designed and proposed for a single family or detached accessory structure El 2. The photovoltaic panels and modules and supporting structure shall be constructed of 0 noncombustible materials or fire-retardant treated wood equivalent to that required for the roof construction. The installation shall meet the requirements of the International Fire Code as amended by WA State. Pv modules are listed and labeled with a fire classification in accordance with UL 1703 3. The PV system is designed for the wind speed of the local area and will be installed per the manufacturer's specifications. 4. The ground snow load does not exceed 70 pounds per square foot.The PV system is designed for the wind speed of the local area,and will be installed per the manufacturer's specifications. 5. Total dead load of modules,supports,mountings,raceways and all other appurtenances weigh no more than four pounds per square foot. Enter total dead load of system(lbs/ft). [2.63 PSF 6. Supports for solar modules are installed to spread the dead load across as many roof-framing members as needed to ensure that no point load exceeds fifty(50)pounds. Modules are mounted no higher than 18"above the surface of the roofing to which they are affixed and do not exceed the highest point of the roof unless approved by the local jurisdiction. E::::> NOTE: If site Inspection indicates a concem that the roof structure is not adequate to support the PV modulle(s), engineering may be required prior to final of the permit. As the property owner or authorized representative of the above listed property, I attest that all information in this checklist is accurate to the best of my knowledge. Applicant Signature: Date: 7/14/2015 Applicant Name(Please Print): (i+n S. Fleming, Power Trip Energy Co Relationship to Property Owner: Installation Contractor T:\BUILDING\APPLICATION FORMS\SOLAR PERMIT CHECKLIST.DOC 10th St NORTH Proposed PV Approximate array on South property line roof of house PF" Proposed inverter (-=!3 an fo Proposed solar production meter&AC disconnect next to City d PA net meter 6 0(M h S t Alley to south -Mai pogi Aagisdaz 141-*— I.-OM 920,15 Twmiytf Us* Rmon a nuo eir _7 Sunrnodule;/ Pro-Series XL SW 315-320 MONO REALVALUE L N I CK, 0 TUV Power controlled: Lowest measuring tolerance in industry Every component is tested to meet 3 times IEC requirements Designed to withstand heavy accumulations of snow and ice Sunmodule Plus: Positive performance tolerance 2S year 25-year linear performance warranty and 10-year product warranty Oil World-class quality v Fully-au tomated production lines and seamless monitoring of the process and mate- D E t rial ensure the quality that the company sets as its benchmark for its sites worldwide. P=I C-11-1 SolarWorld Plus-Sorting Plus-Sorting guarantees highest system efficiency.SolarWorld only delivers modules UL 1703 that have greater than or equal to the nameplate rated power. I (t /C�E\- 25-year linear performance guarantee and extension of product warranty to 10 years SolarWorld guarantees a maximum performance digression of 0.7%p.a.in the course of 25years,a significanl.added value compared tothe two-phase warranties common in the industry,along with our industry-first 10-year product warranty! *in accordance with the applicable SolarWorld Limited Warranty at purcha5e. v,,ww.solarworld.com/warranty Quality modules mad-6,-y solarworld.com W-,V,0 L_41 0 L Sunmodule;-"' Pro-Series XL S 0 L A R'Ai OR L D SW 315-320 MONO RE'ALVALUE L PERFORMANCE UNDER STANDARD TEST CONDITIONS(STC)' SW 31S SW320 maximum power P—. 315Wp 320 Wp Open circuit voltage V� 45.6 V 45.9 V Maximum power point voltage V"' 36.5 V 36.7 V Short circuit current 93S A 9,41 A Maximum powerpoint current 1',. 8.71 A 8.78 A Module efficiency 16.03% 16-28% Measuring tolerance(P,,,,)traceable to TUV Rheinland:+1-2%(TUV Power controlled) 'STC:1000W/ml,25'C,AM 1.5 PERFORMANCE AT 800 W/Mz,NOCT,AM 1.5 SW-315 SW320 Maximum power P.. 240.9 Wp 244.4 V/p Open circuit voltage V� 39.8 V 40.1 V Maximum powerpoint voltage V PP 33.6 V 33.8 V Short circuit current 1�1 7.77 A T82 A Maximum power point current 119P 7.18 A 7.18 A Minor reduction in eff iciency under partial load conditions at 25'C:at 200 W/m�,100%(+/-2%)of the STC efficiency(1000 W/ml)is achieved. 1000 W/.rrp DIMENSIONS COMPONENT MATERIALS 800 W/M� Length 78.15 in(!985 mm) Cellspermodute 72 Width 38.98 in(990 mm) Cell type Mono crystalline 600 W/rn� Height 181 in(46 mm) Cell dimensions 156 mm x 156 mm 400 W/rn- Frame Clear anodized aluminum 3.2 mm Tempered glass Front (EN 12150) Weight 49.6 lbs(22.5 kg) 200 W/M2 100 W/rn� THERMAL CHARACTERISTICS ADDITIONAL DATA Module voitagr(VI V, NOCT 46'C Powersorting -0 Wp/+S Wp Tcl� 0.042%/K J-Box IP65 TCV, -0.304%/K Connector KSK4 0 0 1,14) TCP.Pl -0.43%/K Modulefire performance (UL 1703)Type I L PARAMETERS FOR OPTIMAL SYSTEM INTEGRATION q Maximum system voltage SCIIINEC -.)r4VW 1000 V Maximum reverse current 2SA Loadlaynarnicload 113/64 p 4/2.4 kN/ml) Number of bypass diodes 3 Operating range -40'C to+85'C 0.6 in('15mm) 1.8 in,(46mrn) 4 6(118) 9.0 199c) All units provided are imperial.51 units provided in parentheses. SolarWorld AG reserves the right to make specification changes without notice. 0 98 in.(25mm) SW-01-6056US 11-2014 Friday,January 31,2014 Snap rack- SnapNrack No r m a n 775 Fiero Lane,Suite 200 San Luis Obispo,CA 93401 Scheel "Series 100 Roof Mount" Cover Letter To Whom It May Concern, We have performed calculations for the 100 series roof mount PV system based on Structural the information provided by SnapNrack. Included with this letter are the report and calculations. We did the calculations in accordance with the 2012 IBC, ASCE 7-10, 2112 NDS, and guidelines stated in the Solar America Board for Codes and En g i n e e r Standards. Some of the components in the SnapNrack test data were used to detennine the 5022 Sunrise Blvd. capacity and section properties of materials. We collected the test data using the fair Oaks,CA 95628 procedures outlined in the 2012 IBC Chapter 17. (916)536-9585 (916)536-0260(fax) We included the following types of load combinations and building parameters into our calculations: 1989-2013 24 yeanv of e_vcellence 0 ASCE 7-10 wind speeds from 110 mph to 190 for B and C exposure categories • ASCE 7-10 Seismic Design Category E • ASCE 7-10 Snow Loads up to 120 psf ground snow • Buildings with mean roof heights up to 60 foot tilt angles / roof pitches Norman Scheel,S.E. from 0 degrees to 60 degrees. LFED AP BD+C LEED AP Homes The calculations have also been completed in accordance with the 2006 IBC,2009 Fellow—SEAOC IBC,and ASCE 7-05. To use the data contained in this packet for projects that are Feflow-ASCE E-mail:norm W .sc.co being evaluated to the older ASCE 7-05 wind speeds,refer to Appendix A for a kni Rob Coon wind speed conversion chart. Find the ASCE 7-05 (IBC 2006/2009)wind speed in Cieneral Manager the Chart in Appendix A,identify the corresponding ASCE 7-10(IBC 2012)wind E-mail:robcoonk?nsse.coi speed value,and proceed with using the charts contained in this packet with the Steve Smith P.E. adjusted wind speed value. Project Manager E-mail:sievesmilbCa,nsse.com In our opinion, the mounting system, outlined by SnapNrack Series 100 PV Mounting System Code Compliance Installation Manual, is acceptable and meets Steven Cooksey the loading requirements as stated above. See the report and calculations included CAD Supervisor E-mail: with this letter for more information. Jacide Winslow If there are any further questions,please contact Nomi Scheel. N Office Manager r-inail:iackic,((�iissc.co,n Norman Scheel PE, SE LEED-AP BD+C,LEED-AP Homes Fellow S OC FeWw C.E� EXPIRES DECEMBER 26. 1,#E] SnapNrack Series 100 Snap rack- Project Info: Dealerd Power Trip Energy Project Name: Nickolaus Create Dated 2015-07-14T12:47:04-0700 BOM#:1 35989 PV Module Data: Module Brand SolarWorld Length 78.46 inches Model SunModule SW 31S XL Width 39.4 inches Depth 1.80 inches Environmental Requirements: Weight 47.60 pounds Topographic Condition Standard Rated power @ STC 31500 W Standard IBC 2012 Rail Color Snow Load 21-30 psf -y_.Ve1A Racking Color Wind Speed 130 mph - --I:TE K Rafter Spacing 24 inches Roof Attachmenti Flashed L-Foot System Style: Rail Finish Black Anodized End Clamp Type Universal Grounding Method Lay-ln-Lugs w/nut Micro Attachment Kits No Edge Screen Trim'� N:o��if"Yes",4"or 8" screen? Screen Height inches Tilt Up, No Sub-Arrays: I UL2703 No Premium Alloy Rail No Bulk Customer No Sub-Array Sub-Array 122" Rail 162" Rail Rail Mid End Edge Roof Modules Splices Clamps Clamps Screen Attachments 1 20 3 8 6 34 12 0 38 TOTALS 20 3 8 6 34 12 0 38 Page I of 3 Nickolaus Solar Racking SnapNrack Series 100 Calculator Proposed Bill of Materials Part Number Description Qty 015-09826 SNAFNRACK,STANDARD RAIL SET, 1621N, BLACK,6 PC 1 015-09816 SNAPNRACK,STANDARD RAIL SET, 1221N, BLACK, 2 PC 2 015-09818 SNAPNRACK,STANDARD RAIL SET, 1621N, BLACK,2 PC 1 242-04013 SNAPNRACK ASSEMBLY RAIL SPLICE,STANDARD, BLACK 6 242-02124 SNAPNRACK MID CLAMP W/CHANNEL NUT, 1.5-2.01N,CLEAR 34 242-02215 SNAPNRACK ASSEMBLY, UNIVERSAL END CLAMP WAVE, REV 2 12 232-01023 SNAPNRACK RAIL END CAP,STANDARD, BLACK 12 242-92051 1SNAPNRACK KIT, L FOOT W-BASE,COMPOSITION FLASHING, BLACK 38 051-03418 ILAY-IN LUG AND LONG#10-32 SS SCREW AND NUT BAG OF 10-UL 4 F-Total Weight: 68.88 lbs -System Total Weight: 1130.00 lbs jArrayArea=20 modules x(39.4"x 78.46"/144 sq.inch persf)=429 sf 1pounds per Square Foot of Array=1130 lbs/429 sf=2.63 psf Item 5 checklist Pounds per attachment=1130 lbs/38=29.7 lbs per attachment Item 6 checklist Page 2 of 3 Modules Per 11 Array Pitch(degrees) 34 Sub-Array Modules 20 Row Module 2 Building Height(ft) 15 Edge Screen(ft) 0 Rows Attachment Spaci.ng I Attachment Spacin Orentation Portraft (inches) ——72 1 Override(inches)g 1 48 Array Power(kW) 6.3 The maximum recommended rail span for this sub-array is 72 inches.The rail span for modules located in edge zones Is reduced by 24 inches to 48 inches Group I Rail Grou p 2 Rail Group 3 Rail Group 4 Rail Group 5 Rail 122"Rail 162"Rail Row Mid Row End Row Attach- Module Rail Length Length Length Leneth Length QtY Qty Clamps Clamps Splices ments BondiUL_ Bonding 318.20 39.40 1 4 14 8 2 18 8 5 F11111 4-38.40 2 4 20 4 4 20 12 2 111101111111111000 Sub-Array 3 8 34 12 6 38 20 7 Totals Nickolaus Solar Racking Page 3 of 3