HomeMy WebLinkAbout606 Milwaukee Drive Address: 606 Milwaukee Drive PREPARED 8/18/14, 13:06:55 INSPECTION TICKET PAGE 1 CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 8/18/14 ------------------------------------------------------------------------------------------------ ADDRESS 606 MILWAUKEE DR SUBDIV: CONTRACTOR : PHONE : - OWNER HALBERG, SHWAN PHONE ; (360) 461-4379 PARCEL 06-30-00-1-0-3910-0000- APPL NUMBER: 13-00001169 RES ADDITION ------------------------------------------------------------------------------------------------ PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ BL1 01 12/18/13 PB BLDG FOUNDATION FOOTING 12/19/13 AP December 18, 2013 10:42:21 AM pbarthol. alex 460-4248 December 19, 2013 10:00:21 AM pbarthol. January 7, 2014 8:36:39 AM pbarthol. BL2 01 1/07/14 PB BLDG FOUNDATION STEM WALL 1/08/14 AP January 7, 2014 8:36:58 AM pbarthol. Alex 460-4248 January 8, 2014 10:05:07 AM pbarthol- BL9 01 4/04/14 JLL BLDG SHEARWALL 4/07/14 AP April 4, 2014 11:04:27 AM pbarthol. Ron 461-4644 April 7, 2014 10:10:42 AM jlierly. BL3 01 S/29/14 JLL BLDG FRAMING 5/29/14 DA May 29, 2014 9:06:03 AM jlierly. ron 461-4644 May 29, 2014 2:10:00 PM jlierly. Framing is ok just need to call electrical rough in first before frame can be approved/jll BAIR 01 6/12/14 JLL BLDG AIR SEAL 6/12/14 AP June 12, 2014 10:11:46 AM pbarthol. June 12, 2014 4:17:14 PM jlierly. BLI 01 6/12/14 JLL BLDG INSULATION 6/12/14 CA June 12, 2014 10:11:23 AM pbarthol. June 12, 2014 4:16:34 PM jlierly. This inspection was needed the following day will reschedule/jll BL3 02 6/12/14 JLL BLDG FRAMING 6/12/14 AP June 12, 2014 10:11:04 AM pbarthol- June 12, 2014 4:17:14 PM jlierly. BLI 02 6/16/14 JLL BLDG INSULATION 6/16/14 AP June 12, 2014 4:18:52 PM jlierly. RON June 13, 2014 1:31:09 PM jlierly. Contractor called and said they brought the wrong 'i'nsulation and wanted to push the inspection back till Monday/�jll June 1G, 2014 4:02:11 PM jlierly. BL99 01 8/18/14 JLV—\ BLDG FINAL August 18, 2014 8:58:22 AM pbarthol. Ron 461-4G44 --------------------- ------------------------------------------------------------------- PERMIT: ME oo KEcHANir-AL'ARMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ ME1 01 6/12/14 JLL MECHANICAL ROUGH-IN ----------------------------------- CONTINUED ONTO NEXT PAGE ----------------------------------- PREPARED 8/18/14, 13:06:SS INSPECTION TICKET PACE 2 CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 8/18/14 ------------------------------------------------------------------------------------------------ ADDRESS . : 606 MILWAUKEE DR SUBDIV: CONTRACTOR : -PHONE : OWNER HALBERG, SHWAN PHONE : (360) 461-4379 PARCEL 06-30-00-1-0-3910-0000- APPL NUMBER: 13-00001169 RES ADDITION ------------------------------------------------------------------------------------------------ REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ 6/12/14 AP June 12, 2014 10:12:00 AM pbarthol. June 12, 2014 4:17:14 PM jlierly. ME99 01 8/18/14 MECHANICAL FINAL August 18, 2014 8:58:39 AM pbarthol. Ron 461-4644 --------------------- ------------------------------------------------------------------- PERMIT: PL 00 PLUMBING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ PL2 01 5/29/14 JLL PLUMBING ROUGH-IN 5/29/14 A�, May 29, 2014 9:06:29 AM jlierly. M.y 29, 2014 2:10:51 PM ilierly. PL99 01 8/18/14 PLUMBING FINAL August 18, 2014 8:59:04 AM pbarthol. Ron 461-4644 ---------------------- --------- COMMENTS AND NOTES -------------------------------------- CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY& ECONOMIC DEVELOPMENT- BUILDING DIVISION 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Application Number . . . . . 13-00001IG9 Date 10/24/13 Application pin number . . . 7GG921 Property Address . . . . . . GOG MILWAUKEE DR ASSESSOR PARCEL NUMBER: 06-30-00-1-0-3910-0000- REPORT SALES TAX Application type description RES ADDITION Subdivision Name . . . . . . on your state excise tax form Property Use . . . . . . . . to the City of Port Angeles Property Zoning . . . . . . . RS9 RESDNTL SINGLE FAMILY Application valuation . . . . 44G47 (Location Code 0502) ---------------------------------------------------------------------------- Application desc GARAGE/DECK/CARPORT/MASTER BATH ADDITION ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ HALBERG, SHWAN OWNER 131G WEST 5TH STREET PORT ANGELES WA 983G3 (360) 461-4379 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT -RESIDENTIAL Additional desc . . GARAGE/DECK/CARPORT/MSTR BATH Permit Fee , . . . G19.75 Plan Check Fee 402.84 Issue Date . . . . 10/24/13 Valuation . . . . 44647 Expiration Date 4/22/14 . Qty Unit Charge Per Extension BASE FEE 417.75 20.00 10.1000 THOU BL-25,001-50K (10.10 PER K) 202.00 --------------------------------------------------------7------------------- Permit . . . . . . MECHANICAL PERMIT Additional desc . . MSTR BATH/GARAGE/DECK Permit Fee . . . . 57.25 Plan Check Fee .00 Issue Date . . . . 10/24/13 valuation . . . . 0 Expiration Date 4/22/14 .Qty Unit Charge Per Extension BASE FEE 50.00 1.00 7.2500 EA ME-VENT FAN (SINGLE DUCT) 7.25 ---------------------------------------------------------------------------- Permit . . . . . . PLUMBING PERMIT Additional desc MASTER BATH ADDITION Permit Fee . . . . 92.00 Plan Check Fee .00 Issue Date . . . . 10/24/13 Valuation . . . . 0 Expiration Date 4/22/14 Qty Unit Charge Per Extension BASE FEE 50.00 3.00 7.0000 EA PL-PLUMBING TRAP 21.00 1.00 7.0000 EA PL-WATER LINE 7.00 2.00 7.0000 EA PL-DRAIN VENT PIPING 14.00 ---------------------------------------------------------------------------- Special No tes and Comments October 24, 2013 10:40:11 AM sroberds. Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is7not commenced within,180 days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced, or if required'inspecti6ns have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws,and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. (0- Date Print Name Signature of Contractor or Authorized Agent Sig ature ner(if owner is builder) T:Fo�ms/Building Division/Building Permit BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS— Building Inspections. 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL,TO COVER, INSULATE OR CONC�Al-ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION: Footings Stemwall Foundation Drainage/Downspouts Piers Post Holes(Pole Bldgs.) PLUMBING: Under Floor I Slab Rough-in Water Line(Meter to Bldg) Gas Line Back Flow/Water FINAL Date Accepted by AIR SEAL: Walls Ceiling FRAMING: Joists/Girders/Under Floor Shear Wall/Hold Downs Walls/Roof/Ceiling Drywall(Interior Braced Panel Only) T-Bar INSULATION: Slab Wall/Floor/Ceiling MECHANICAL: Heat Pump/Furnace/FAU/Ducts Rough-In Gas Line Wood Stove/Pellet/Chimney Commercial Hood/Ducts FINAL Date Accepted by MANUFACTURED HOMES: .Footing/Slab 1131ocking&Hold Downs ISkirting PLANNING DEPT. Separate Permit#s SEPA: Parking I Lighting ESA: Landscaping ISHORELINE: FINAL INSPECTIONS REQVIREQ PRIOR TO OCCUPANCY1 USE Inspection Type Date Accepted By Electrical 417-4735 Construction-R.W. PW Engineering 417-4831 Fire 417-4653 Planning 417-4750 Building 417-4815 T:Forms/Building Division/Building Permit CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY& ECONOMIC DEVELOPMENT- BUILDING DIVISION 321 EAST 5TH STREET, PORT ANGELES,WA 98362 Page 2 Application Number . . . . . 13-00001169 Date 10/24/13 Application pin number . . . 766921 ---------------------------------------------------------------------------- REPORT SALES TAX Special Notes and Comments Small addition/new garage in RS-9 for total of 9% lot cov on your state excise tax form and 16% site cov. Front yd setback to 101 approved per VAR to the City of Port Angeles 03-09B along Milwaukee Dr. Electrical load calculations and electrical permits are (Location Code 0502) required. Temp erosion control and surface restoration responsibility of applicant' No attachment to sanitary sewer of stormwater roof leaders, foundation drains, yard drains, or any other CSO contribution is allowed. Use existing driveway opening for site access. Consider applying for the City Green Infrastructure Rebate of up to $500.00 towards the materials to install rain garden to control roof and driveway runoff. Contact Jonathan Boehme at 360 417-4811 ---------------------------------------------------------------------------- Other Fees . . . . . . . . .1� STATE SURCHARGE 4.50 ----------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 769.00 769.00 .00 .00 Plan Check Total 402.84 402.84 .00 .00 Other Fee Total 4.50 4.50 � : .00 .00 Grand Total 1176.-34 1176.34 � .00 .00 Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is:not commenced within.180 days,if construction or.work.is suspended or abandoned for a period of 180 days after the work has.commenced,or if require-d:insp'e ctidns have' not been.requested within 180 days from the last inspection. I hereby certffy that I have read and examined this application and know the sameto.be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the.performance of construction. Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder) T:Forms/Building Division/Building Permit BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS— Building Inspections. 417-4815 Electrical Inspections 417-4735 Public Works Utilities 4174831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION: Footings Stemwall Foundation Drainage/Downspouts Piers Post Holes(Pole Bldgs.) PLUMBING: Under Floor I Slab Rough-in Water Line(Meter to Bldg) Gas Line Back Flow/Water FINAL Date Accepted by AIR SEAL: Walls Ceiling FRAMING: Joists/Girders/Under Floor Shear Wall/Hold Downs Walls/Roof/Ceiling Drywall(interior Braced Panel Only) T-Bar INSULATION: Slab Wall/Floor/Ceiling MECHANICAL: Heat Pump/Furnace I FAU/Ducts Rough-in Gas Line Wood Stove/Pellet/Chimney Commercial Hood/Ducts FINAL Date Accepted by MANUFACTURED HOMES: Footing/Slab Blocking&Hold Downs Skirting PLANNING DEPT. Separate Permit#s SEPA: Parking/Lighting ESA: Landscaping ISHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY1 USE Inspection Type Date Accepted By Electrical 417-4735 Construction-R.W. PW I Engineering 417-4831 Fire 417-4653 Planning 417-4750 Building 417-4815 T:Forms/Building Division/Building Permit THE For City Use F CITY POJLA.X OF A _�LE S Permit# J W A S H I N G T 0 N , U. S. Date Received: ('0—'21— 3 2 1 E 51h Street Date Appro"vQed! al 6 Port Angeles,WA 9836 P:360-417-4817 F: 360-417-4711 Email: permits0cityofVa.us BUILDING PERMIT APPLICATION ProjectAddress: 60(, 3 Phone: (-o #71-3a91/5 Primary Contact: m il. Email: 1 !� 66, 1 CO Name C�7 Phone S<-C1--\ A- ?(, ()' q� ( (0-7 Property Maili Adduss Email Owner nt VV\ C�7 City P,�4 State ti Zip Name Phone —Cont-rac-tor— Address Email Information city State Zi Contractor License# Exp.Date: tin� Ta Legal Description: Zoni g: x Parcel# Project Value: (materials and labor) DL-�00(' 10�"Ilo -17 $ &�L Residential 7ff Commercial 0 Industrial Public El Permit Demolition 0 Fire El Repair El Reroof(tear off/lay over) 11 Classification For the followine. fill out both Dages of permit application: (check New Construction El Exterior Remodel Z Addition 11 Tenant Improvement appropriate) I Mechanical El Plumbing El Other El Will a fire sprinkler system be installed Ir-rigation System? Proposed Bathrooms Proposed Bedrooms or modified? Yes 11 No ,9 Yes 0 NoZ[ Project Description Is project in a Flood Zone: Yes El Nop Flood Zone Type: If in a Flood Zone, what is the value of the structure before proposed improvement? $ I have read and completed the application and know it to be true and correct. I am authorized to apply for this permit and understand that it is my responsibility to determine what permits are required and to obtain permits prior to work. I understand that plan review fees are not refundable after review has occurred. I understand that I will forfeit review fees if I withdraw the application before the permit is issued. I understand that if the permit is not picked up/issued within 18o days of submittal,the application will be considered abandoned and the fees will be forfeited. Date Print Name6-r--c) [-("16 Signature Residential Structures For Office Use Area Description(SQ FT) Existing Proposed ss value Basement First Floor '00<� Second Floor Covered Deck/Porch/Entry Deck(over 30"or2'd floor) Garage 0 Carport 0 022 Other(describe) Area Totals Commercial Structures Proposed For Office Use Area Descriptions(SQ FT) Existing Proposed ss Value -Existing-Structure-W Proposed Addition Tenant Improvement? Other work(describe) Site Area Totals Lot/Site Coverage Calculations Lot Size (sq ft) Lot Coverage (sq ft) %Lot Coverage (Total lot coverage+lot size) YI-> �1( 19 C> Wq0' ;0 ,--�'Ll. Site Coverage (Sq Ft of all impervious) %of Site Coverage (total site coverage+lot size) -�, 'g'Z 5- ! - /C -'�a Mechanical Fixtures Indicate how many of each type of fixture to be installed or relocated as part of this project. Air Handle Size: # Haz/Non-Haz Piping Outlets: Appliance Exhaust Fan # Heater(Suspended,Floor,Recessed wall) # Boiler/Compressor Size: # Heating/Cooling appliance # repair/alte ation Evaporative Cooler(attached, not # Pellet Stove/Wood-burniing/Gas # portable) as Stove/Gas Cook Stove/Misc. Fuel Gas Piping #of Outlets: Ventilation Fan,single duct # F Forced Air Unit # Ventilation System # urnace/Heat Pump Plumbing Fixtures Indicate how many of each type of fixtu e to be installed or relocated Plumbing Traps # Fuel gas piping. #of Outlets: Water Heater # Medical gas piping #of Outlets: Water Line # Plumbing Vent piping # Sewer Line # Industrial waste pretreatment interceptor(Grease Trap) Size Other(describe): T:\BUILDING\APPLICATION FORMS\Current BP Application\Building Permit 4-17-13.docx Prescriptive Energy Code Compliance for All Climate Zones in Washington Project Information Contact Information This project will use the requirements of the Prescriptive Path below and incorporate the the minimum values listed. In addition, based on the size of the structure, the appropriate number of additional credits are checked as chosen by the permit applicant. Authorized Representative Date to L Tkil Climate Zones R-Va.lue' U-Factor a Fenestration U-Factor b n/a 0.30 Skylight U-Factor n/a 0.50 Glazed Fenestration SHG Cb., n/a n/a Ceiling 4Y 0.026 Wood Frame Wallg-�" 21 int 0.056 Mass Wall R-Value' 21/2 1 h 0.056 Floor 301 0.029 Below Grade Wa llc,k J 10/15/21 int 0.042 Slab d R-Value& Depth 1 10, 2 ft n/a *Table R402.1.1 and Table R402.1.3 Footnotes included on Page 2. Each dwelling unit in one and two-family dwellings and townhouses,as defined in Section 101.2 of the International Residential Code shall comply with sufficient options from Table R406.2 so as to achieve the following minimum number of credits: '*1. Small Dwelling Unit: 0.5 points Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration area. Additions to existing building that are less than 750 square feet of heated floor area. F-]2. Medium Dwelling Unit: 1.5 points All dwelling units that are not included in#1 or#3, including additions over 750 square feet. F-13. Large Dwelling Unit: 2.5 points Dwelling units exceeding 5000 square feet of conditioned floor area. Table R406.2 Summary Option Description Credit(s) 1 a Efficient Building Envelope 1 a 0.5 1 b Efficient Building Envelope 1 b 1.0 F-1 Ic Efficient Building Envelope 1c 2.0 2a Air Leakage Control and Efficient Ventilation 2a 0.5 2b Air Leakage Control and Efficient Ventilation 2b 1.0 F1 2c Air Leakage Control and Efficient Ventilation 2c 1.5 F-1 3a High Efficiency HVAC 3a 0.5 El 3b High Efficiency HVAC 315 1.0 1-1 3c High Efficiency HVAC 3c 2.0 F-1 3d High Efficiency HVAC 3d 1.0 4 High Efficiency HVAC Distribution System 1.0 5a Efficient Water Heating 0.5 F-1 5b Efficient Water Heating 1.5 1-1 Renewable Electric Energy 0.5 *1200 kwh 0.0 Total Credits 0.00 *Please refer to Table R406,2 for complete option descriptions http://www.energy.wsu.edu/Documents/2012�/�2ORes�/�2OEnergy.pd Table R402.1.1 Footnotes For SI: 1 foot .= 304.8 mm, ci .= continuous insulation, int .= intermediate framing. a R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity which is less than the label or design thickness of the insulation, the compressed R-value of the insulation from Appendix Table A101.4 shall not be less than the R-value specified in the table. b The fenestration U-factor column excludes skylights. The SHGC column applies to all glazed fenestration. Exception: Skylights may be excluded from glazed fenestration SHGC requirements in Climate Zones 1 through 3 where the SHGC for such skylights does not exceed 0.30. C 11 10/15/21.+TB" means R-10 continuous insulation on the exterior of the wall, or R-15 on the continuous insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the basement wall at the interior of the basement wall. "10/15/21.+TB" shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. "10/13" means R-10 continuous insulation on the interior or exterior of the home or R- 13 cavity insulation at the interior of the basement wall. 713" means thermal break between floor slab and basement wall. d R-10 continuous insulation is required under heated slab on grade floors. See R402.2.9.1. e There are no SHGC requirements in the Marine Zone. f Basement wall insulation is not required in warm-humid locations as defined by Figure R301.1 and Table R301.1. Reserved. h First value is cavity insulation, second is continuous insulation or insulated siding, so "13.+5" means R-13 cavity insulation plus R-5 continuous insulation or insulated siding. If structural sheathing covers 40 percent or less of the exterior, continuous insulation R-value shall be permitted to be reduced by no more than R-3 in the locations where structural sheathing is used to maintain a consistent total sheathing thickness. The second R-value applies when more than half the insulation is on the interior of the mass wall. For single rafter- or joist-vaulted ceilings, the insulation may be reduced to R-38. k Int. (intermediate framing) denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation. I Log and solid timber walls with a minimum average thickness of 3.5 inches are exempt from this insulation requirement. Table R402.1.3 Footnote a Nonfenestration U-factors shall be obtained from measurement, calculation or an approved source or as specified in Section R402.1.3. PQRT-ANGELIES W A S H I N G T 0 N, U. -S. A. NOV 10 2005 C'TYOFPORTAN ELES PUBLI WORKS UTILITI.ES DE RT'MENT Dept.ofCommunit Dev lo ment November 9, 2005 Mr. Sean Halberg 1507 East Beach Road . Port Angeles, WA 9836' RE: Milwaukee Drive Improvements Dear Sean: Thank You for your left6rof November 7 2005 regarding the sidewalk improvements required for your n4r residence. We er regarding the extent of frontage improvements that would had met with you earli new residence. Normally they would have been required be required for your frontage of app for the full extent of your roximately 414 feet. Due to the shape of the lot for a boundary adjustmen and the potential t with the property to the north and east the frontage improvement requirements were reduced to just beyond your proposed building with a LID agreement for the re no protest mainder. With your present driveway 1�3 location this reduced your frontage requirements by 174 feet to approximatel 240 feet.-U i sing Your construction cost esti y mates ($�l.30/L.F.)this reduction will save you $5,446 plus the cost of pa Vement widening for 174 feet. K." The sidewalk improvements were cleady noted on your buil ding permit. You could have appealed the requirements when the permit appealpe was issued, but the Hod has passed. The street requirements are fromthe City's Urban Services for Street and Access Requirements(PAMC 18-08.040D,ordinance '. 2857 adopted 2/17/95)that states "De Yelopment that creates pedestrian on any arterial streets and other streets id.entified in the CftYs transportation plan (b traffic as school-walking routes shall include pedestrian sidewalks." Milwaukee Drive is an arterial and the sidewalk improvern ents areTequired. In addition Milwaukee Drive is a.part of the waterfront trail system. e - Please call if you have questions. Sin&re y, .......... Gary W. K Y Deputy Director of Public Works/City Engineer cc:Genn Cut*,Jim Lierly Trenia Funston MMMENGINEEMBuild' ing C0­:spmdence\HaIberS wwaukee Side"Jk.doc 321 EAST FIFTH STREET *_P 0. BOX If 50 0 PORT ANGELES, WA 98362-0217 PHONE: 36,0-417-4805 0 FAX: 360-417-4542 TTY. 360-417-4645 E-MAIL: PUb1iCW0rksCcDcjty0fpa.US le I IfIt,,q, Pold "I GRADE - 14%GRADE 3%GRADE 7Z GRADE SECTIN 59 SECTIDN D-D SECTIDN E-E 7'—112 —----------------T r L -J24 Ln -------------------------------- ------------------—-— O""'s G R Arj'-::. COINCRET� SUBI -OK,�,IAUED FUL S!-L;�E 10 6001� El L -J 30 --------------------------------- L ----------------------------- VERIFY LOCATION OF TOP OF BLUFF fPOA,r 10-0 st C/( fT. PROPOSED RESIDENCE Af 7j, 59, 414.56, C-1 4 N CURB CUT PER CITY OF PORT ANGELES REQUIRMENTS APPROXIMATE LINE OF TOP OF MARINE 13WFF BLUFF SETBACK LINE P_ER GEOTECH REPORT SETBACK FOR ACCESSORY STRUCTURES BUILDING SETBACK LINES PC ZONIN CODE 144.5 REQUESTED ACK UNES N PROPERTY Ll <4 EXISTIN&EDGE-Or 'P, _,AVEMEJV-r' ------------- + 4p 0� Wz, 07 -�,V%� A-w k� R t t S, P -Iq 14 3850 PR 3068 3850 SH FULL LITE SH 4050 4106:1 TEMP SLII�l:! SH SH 3050 L /oso SH GREAT ROOM >H i sos T4050 41068 BEDROOM EMP —SLIDER SHOWER C__ 4050 3 3050 S. AO G IH TNP 0 0 KITCHEN BATHROOM F C SET 3030 S. 2036 2036 2036 4 30 C =pl ATH' TflsE ASE CASE CASE so H 3850 PR 3068 3850 SH FULL LITE SH 4a5O 4050 SH 4 50 4050 SH SH SH 4050 3020 SH I FAMILY ROOM SH 06B BEDROOM BEDROOM ULL LITE 306 4030 2668 SH 2 611 a,x 16, OFFICE FLAU.DRl ROOM 0 GARAGE DOOR HRO M 8 X P-1 G"IRAG3E' DOOR 0'6 1)16 3016 S", SH FRAMING & FOUNDATION DIM. FINISH PER ELEVATION / AIR INFILTRATION BARRIER 4" CONCRETE SLAB 7 16" OSB SHEATHING OR 4" GRANULAR FILL PE� SHEARWALL SCHEDULE 2X6 STUDS 0 16" O.C. 2X6 P.T. SILL W1 5/8" X 10" A.B. PER SHEARWALL SCHEDULE OR L& (48" O.C. TYP.) 12" MAX FROM Ld Pf ENDS & JOINTS (7" MIN EMBED) — z Lc #4 HOR. REBAR @ 24" O.C. �A FIN. GRADE I 1 0 I.it #4 VERT. REBAR 0 48" O.C. 4" DIA. DOWNSPOUT TIGHTLINE F11 TO APPROVED DISCHARGE 00 ___T_r7 4" DIA. PERF. PIPE PEA GRAVEL FILL WRAP W1 FILTER FABRIC (2) #4 CONT. @ BOT. FTG. MIN 3" CLR. TO EARTH �3/ 5��-�30 ANG TOP �0�36 CA S 3068 [76C rIXEII rEM1 4030 EM IM FSMH 6--1 0 50] SH [iH F------7 -T C!Ty OF PORT ANGELES PIP is.-,umnce of this perMP4 i,,erd upon these plans,Sp�?-ifil- cations and other dat? not prp%��nt the building official tforn thereafter reqLr4:,rjQ -m of errors in -said g the corre& MY pn., specifications and other data, ir from prevpnting building operations being carried on thereunder when in -,-�—Gs of this jurisdiction. of all codes aiJ 0_ )EVe- 050] 3850 4050] SH SH SH PR3068 4[068 FULL LITE S-IDER I F SH 3850 4050 3020 F4050 850] SH PR30168 SH SH PR3068 SH FULL FULL LITE LITE 1"A(/l/ F L-c/ 3850 PR 3068 3850 SH FULL LITE SH 4050 41068 4050 4050 TEMP SLIDER SH SH 3050 4050 SH GREAT ROOM G-- SH 4050 41068 BEDROOM TEMP SLIDER SHOWER 4050 30 3050 SH ANG SH TOP -INE KITCHEN 7 HR OOM CLOSET 3030 SH 2036 2036 2036 4030 CASE CASE CASE SH 3850 PR 3068 3850 SH FULL LITE SH 4050 4050 F-7:1 SH SH 4050 4050 LL1 L'Al SH SH -1 81-91 3020 4050 12'-0'- SH SH FAMILY ROOM G== I PR3068 BEDROOM BEDROOM FULL LITE 3 4j' 4030 2668 3068 SH r pr-a ; 8' X 16 OFFICE 0 GARAGE DOOR LAUNDRY ROOM :0 IMTHRO IM 0 2 81 x 81 F- 1 GARAGE DOOR T 4 4 ------ 3016 3016 3016 SH SH SH V-61" 2 - - - - - - - - - - - - - - - - - - - - -1 -i > > CTJ - - - - - - - - - - - --- - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2'-1 5'-10-71 4 4 10' 11 lGi to co F- - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - --I � -/75 2'-1 1 2'-6 8'-0 2'-0" 16'-0" 2 ,31'-51" 2 8'-0 7-1 1 7 F 7 FF 7 7 F L _JL _JL JL _J L _J L JIL __j4L__ L_ r- 7 F- 7IF___1 F 7 F F=- F- F-7-F- ---ff r-- "i f----t f i