Loading...
HomeMy WebLinkAbout830 W. Lauridsen Blvd. Address: 830 W Lauridsen Blvd. PREPARED 4/18/16, 9:08:37 INSPECTION TICKET a r G 3 CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 4/18/16 ------—-—--------- ------—---------------------------—----------------------—------------ ADDRESS . : 830 W LAURIDSEN BLVD SUBDIV: CONTRACTOR AIR MANAGMENT SOLUTIONS LLC PHONE (360) 479-6500 OWNER CLALLAM TRANSIT SYSTEM PHONE PARCEL 06-30-09-5-0-9190-0000- APPL NUMBER: 16-00000452 COMM MECHANICAL PERMIT -----—------------------------------------------------------------------------------------ PERMIT: ME 00 MECHANICAL PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED...R T RESULTS/COMMENTS ------------------- --- ------—-----------------------------------—-- ---- ME99 01 4/18/16 L MECHANICAL FINAL April 15, 2016 9:59:07 AM jlierly. Cathy 360-460-7712 -------------------------------------- COMMENTS AND NOTES -------------------------------------- r - CITY OF PORT ANGELES - y - } DEPARTMENT OF COMMUNITY& ECONOMIC DEVELOPMENT-BUILDING DIVISION 321 EAST STH STREET, PORT ANGELES,WA 98362 t I jApplication Number . . . . . 16-00000452 Date 4/11/16 r I Application pin number . . . 867580 Property Address . . . . . . 830 W LAURIDSEN BLVD REPORT SALES TAX ASSESSOR PARCEL NUMBER: 06-30-09-5-0-9190-0000- On your state excise fax form Application type description COMM, MECHANICAL PERMIT � Subdivision Name . . . . . . to the City of Port Angeles Property Use . . . . . . . (Location Code 0502) Property Zoning . . . . . . . UNKNOWN Application valuation . . . . 3494 ---------------------------------------^--------------------"•--------^---- Application desc ..REPLACEMENT OF EXHAUST FA_-----.-..-------------'---LL-------------------------------------------- - OwnerContractor i _ ------------------------ ------------I----------- CLALLA14 TRANSIT SYSTEM AIR MANAGMENT SOLUTIONS LLC 830 LAURSDSEN BLVD 5822 W WERNER RD PORT ANGELES WA 98363 BREMERTON WA 98312 (360) 479-6500 - --------------^------ ----------------------- -- -------------------- ---- k Permit MECHANICAL PERMIT Additional desc REPLACEMENT OF EXHAUST FAN Permit Fee 57.25 Plan Check Fee .00 F %A Issue Date . . . . 4/11/16 Valuation . . . . 0 1 Expiration Date . . 10/08/16 1]i �• Qty Unit Charge Per Extension S BASE FEE 50.00 , 1.00 7.2500 EA ME-VENT FAN (SINGLE DUCT) 7.25 a _--a_._..-------------^-----------------------------------•---------- Fee summary Charged - Paid- Credited ----Due - Permit Fee Total 57.25 57.25 .00 .00 i Plan Check Total .00 .00 .00 .00 Grand Total 57.25 57.25 .00 .00 3•�t f � I I Separate Permits are required forelectrical work,$EPA,Shoreline,ESA,utilities,private and public improvements.This permitbecomes `�— null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned f for a period of 180 days after the work has commenced,or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions J of laws and ordinances governing this type of work will be complied with whether 9 a ified herein o_r not. The granting of a permit does not presume to give authority to violate or cancel the provision of any state or ca law regulatirfg onstruction or the performance of construction. H ii Q+( Date Print Name Signature of Contractor or Authorized Ag t Sig ature of Owner(if owner is builder) T:Forms/Building Division/Building Permit {{ Address: 830 W Lauridsen Blvd. PREPARED 9/11/13, 12:19:59 INSPECTION TICKET PAGE 2 CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 9/11/13 ---—---------—-------------------------------------------—-----------------—---------------- ADDRESS . : 830 W LAURIDSEN BLVD SUBDIV: CONTRACTOR HOCH CONSTRUCTION PHONE (360) 452-5381 OWNER CLALLAM TRANSIT SYSTEM PHONE PARCEL 06-30-09-5-0-9190-0000- APPL NUMBER: 13-00000268 COMM REMODEL ------------------------------------------------------------------------------------------------ PERMIT: BPC 00 BUILDING PERMIT - COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ----—------—----—----------------—-------------------—- -- ------------- BLTB 01 4/04/13 JLL BLDG T-BAR 4/04/13 AP April 4, 2013 8:32:16 AM pbarthol. Kyle 461-0043 Call Kyle he'll meet you there April 4, 2013 4:04:07 PM jlierly. BL99 01 9/11/13 -JL BLDG FINAL September 9, 2013 9:36:38 AM pbarthol. kevin417-1359 -------------------- -- ---- ------ ------------- COMMENTS AND NOTES BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS Building Inspections. 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION: Footings Stemwall Foundation Drainage/Downspouts Piers Post Holes(Pole Bldgs.) PLUMBING: Under Floor/Slab Rough-In Water Line Meter to Bldg) Gas Line Back Flow/Water FINAL Date Accepted b AIR SEAL: )_ Walls Ceiling FRAMING: Joists/Girders/Under Floor Shear Wall/Hold Downs Walls/Roof/Ceiling Drywall Interior Braced Panel Only) T-Bar INSULATION: Slab Wall/Floor/Ceiling MECHANICAL: Heat Pum /Furnace/FAU/Ducts Rough-In Gas Line Wood Stove/Pellet/Chimney Commercial Hood/Ducts FINAL Date Accepted b MANUFACTURED HOMES: Footing/Slab Blocking&Hold Downs Skirting PLANNING DEPT. Separate Permit#s SEPA: Parkin /Lighting ESA: Landscaping SHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE Inspection Type Date Accepted By Electrical 417-4735 Construction-R.W. PW I Engineering 417-4831 t Fire 417-4653 Planning 417-4750 Building 417-4815 T:Forms/Building Division/Building Permit CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY&ECONOMIC DEVELOPMENT- BUILDING DIVISION 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Application Number . . . . . 13-00000268 Date 3/21/13 Application pin number . . . 906044 Property Address . . . . . . 830 W LAURIDSEN BLVD ASSESSOR PARCEL NUMBER: 06-30-09-5-0-9190-0000- REPORT SALES TAX Application type description COMM REMODEL Subdivision Name . . . . . . on your State excise tax form Property Use . . . . to the Cit of Port Angeles Property Zoning UNKNOWN Y 9' Application valuation . . 3000 (Location Code 0502) ----------------------------- Application desc NEW SUSPENDED CEILING IN PARATRANSIT AREA ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ CLALLAM TRANSIT SYSTEM HOCH CONSTRUCTION 830 LAURIDSEN BLVD 4201 TUMWATER TRUCK RT PORT ANGELES WA 98363 PORT ANGELES WA 98363 (360) 452-5381 ---------------------------------=------------------------------------------ Permit . . . . . . BUILDING PERMIT - COMMERCIAL Additional desc . . DROP CEILING Permit Fee . . . . 109.75 Plan Check Fee .00 Issue Date . . . . 3/21/13 Valuation . . . . 3000 Expiration Date 9/17/13. Qty Unit Charge Per. Extension BASE FEE 95.75 1.00 14.0000 THOU BL-2001-25K (14 PER K) 14.00 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE SURCHARGE 4.50 • ---------------------------------------------------------------------------- Fee summary .Charged Paid Credited Due t ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 109.75 109.75 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 4.50 4.50 .00 .00 Grand Total 114.25 114.25. .00 .00 Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder) T:Forms/Building Division/Building Permit THE ri m For City Use CITY QF lr�t!/O Permit# W A S H I N G T o N , U . S. Date Received: 321 E. First Street Date Approved Port Angeles, WA 98362 P: (360)417-4817 F: (360)417-4711 E-mail: permits@cityofpa.us Building Permit Application Project Address: Primary Contact: Phone # E-Mail: Property Name � Phone �(a D Owner Mailing Address Email CityPC* n State Zip p Iljyl W 10 Contractor Name Phone Information �hrS e • �' 46 ol- 3 License# e4C(J gI"), Email Expiration Date: 9 Legal Description: Zoning: Tax Parcel # Project Value: (materials and labor) $ Residential ❑ Commercial ® Industrial ❑ Public ❑ Permit Demolition ❑ Fire ❑ Repair ❑ ' Reroof(tear off/lay over) ❑ Classification (check For the following, fill out both pages of permit application: appropriate) New Construction ❑ Exterior Remodel ❑ Addition ❑ Tenant Improvement ❑ Mechanical ❑ Plumbing ❑ Other Existing Fire Sprinkler System? Maximum height of structure Proposed Bedrooms Proposed Bathrooms Yes 0 No ❑ Project SVS Descriptions E'�D 1, nJ _ Z(a x Zlo Is project in a Flood Zone: Yes ❑ Nor Flood Zone Type: If in a Flood Zone, what is the value of the structure before proposed improvement? $ I have read and completed the application and know it to be true and correct. I am authorized to apply for this permit and understand that it is my responsibility to determine what permits are required and to obtain permits prior to work. I understand that plan review fees are not refundable after review has occurred. I understand that I will forfeit review fees if I withdraw the application before the permit is issued. I understand that if the permit is not picked up/issued within 18o days of submittal, the application. will be considered abandoned and the fees will be forfeited. 01 Date 3-2-0 — [2,> Print Name i��l> (�rzc5-� Signature Residential Structures For Office Use Area Description (SQ FT) [Existing] Proposed $$value Basement First floor Second Floor Covered Deck/Porch/Entry Deck(over 30"or z" floor) GarageIF — Carport `,• Other (describe) Area Totals ,t Commercial Structures _ -For Office Use Area Descriptions (SQ FT) Existing Proposed $$Value' Existing Structure (s)' Proposed Addition i T mane Improvement? Other work (describe) Sile Area Totals i L Lot/Site Coverage Calculations Lot Size :%Lot Coverage (Sq Ft of all Structures): %Site Coverage (Sq Ft of all impervious surfaces including structures) Mechanical Fixtures Indicate how many of each type of fixture to be installed or relocated as part of this project. Air Handler Size: # Haz/Non-Haz Piping #of Outlets: Appliance Vent # Heater(Suspended, Floor, Recessed wall) # Boiler/Compressor Size: # Heating/Cooling appliance # repair/alteration Evaporative Cooler(attached, not # Pellet Stove/Wood-burning/Gas # portable) Fireplace/Gas Stove/Gas Cook Stove/Mise. Fuel Gas Piping #of Ventilation Fan,single duct # Outlets: Furnace/Heat Pump/ Size: # Ventilation System # Forced Air Unit Plumbing Fixtures Indicate how many of each type of fixture to be installed or relocated. Plumbing Trap Fuel gas piping #of Outlets# Water Heater Water Line Medical gas piping Sewer Line Industrial waste pretreatment interceptor Vent piping# Other T:\BUILDING\APPLICATION FORMS\BUILDING PERMIT 081212.DOCX Address: 830 W Lauridsen Blvd. PREPARED 9/11/13, 12:19:59 INSPECTION TICKET PAGE 4 CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 9/11/13 ------------------------------------------------------------------------------------------------ ADDRESS : 830 W LAURIDSEN BLVD SUBDIV: CONTRACTOR FERRELLGAS LP PHONE (816) 792-1600 OWNER CLALLAM TRANSIT SYSTEM PHONE PARCEL 06-30-09-5-0-9190-0000- APPL NUMBER: 13-00000829 COMM MECHANICAL PERMIT ------------------------------------------------------------------------------------------------ PERMIT: ME 00 MECHANICAL PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS --------------------- ------------------------------------------------------------------- ME99 01 9/11/13 J MECHANICAL FINAL September 9, 2013 9:37:37 AM pbarthol. Kevin 417-1359 -------------------------------------- COMMENTS AND NOTES -------------------------------------- CITY OF PORT ANGELES s� DEPARTMENT OF COMMUNITY& ECONOMIC DEVELOPMENT- BUILDING DIVISION 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Application Number . . . . . 13-00000829 Date 8/12/13 Application pin number . . . 180050 Property Address . . . . . . 830 W LAURIDSEN BLVD ASSESSOR PARCEL NUMBER: 06-30-09-5-0-9190-0000- REPORT SALES TAX Application type description COMM MECHANICAL PERMIT Subdivision Name . . . . . on your state excise tax form Property Use . . . to the Cit of Port Angeles ' Property Zoning UNKNOWN y g Application valuation 7500 (Location Code 0502) Application desc 1000gl PROPANE DISPENSING STATION ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ CLALLAM TRANSIT SYSTEM FERRELLGAS LP 830 LAURIDSEN BLVD 1 LIBERTY PLAZA PORT ANGELES WA 98363 ATTN: OPERATING TAX DEPT. LIBERTY MO 64068 (816) 792-1600 Permit . . . . . . MECHANICAL PERMIT Additional desc . . 1000GL PROPANE DISPENSING STAT Permit Fee . . . . 171.30 Plan Check Fee .00 Issue Date . . . . 8/12/13 Valuation . . . . 0 Expiration Date . . 2/08/14 Qty Unit Charge Per Extension BASE FEE 50.00 1.00 10.6500 EA ME-STOVE/FIREPLACE/MISC. APP. 10.65 1.00 10.6500 EA ME-FUEL GAS PIPING,1-5 OUTLETS 10.65 1.00 50.0000 HR ME-INSPECTION, MIN 1 HR 50.00 1.00 50.0000 HR ME-ADDITIONAL PLAN REVIEW 50.00 ---------------------------------------------------------------------------- Special Notes and Comments August 12, 2013 10:04:26 AM pbarthol. 1. Tank may be located within 10' of building, but the point of transfer must be 25' form the building usnless the exterior wall of the building is a one-hour fire wall, in r�A which case it may waso be at 101 , per NFPA 58, table 6.5.3, �l:l attached 2.Electrical Area Classification shall be per NFPA 58, table 6.22.2.2, attached 3.Dispensing station must meet all provisions of NFPA 58, 6.25 attached 4.All provisions of NFPA 58, 6.25.4 must be met, attached 5.Vehicle impact protection must be provided as shown on the 0 plans. 12,0001b impact protection per 2012 International Fire Code 312.3, attached �1 Fee summary Charged Paid Credited Due Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned d for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. ate Print Name Signature of Contractor or Authorized gen Signature of Owner(if owner is builder) T:Forms/Building Division/Building Permit BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS— Building Inspections 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION: Footings Stemwall Foundation Drainage/Downspouts Piers Post Holes(Pole Bldgs.) PLUMBING: Under Floor/Slab Rough-In Water Line(Meter to Bldg) Gas Line Back Flow/Water FINAL Date Accepted b AIR SEAL: Walls Ceiling FRAMING: Joists/Girders/Under Floor Shear Wall/Hold Downs Walls/Roof/Ceiling Drywall Interior Braced Panel Only) -f-Bar INSULATION: Slab Wall/Floor/Ceiling MECHANICAL: Heat Pum /Furnace/FAU/Ducts Rough-In Gas Line Wood Stove/Pellet/Chimney Commercial Hood/Ducts FINAL Date Accepted b MANUFACTURED HOMES: Footing/Slab Blocking&Hold Downs Skirting PLANNING DEPT. Separate Permit#s SEPA: Parkin /Lighting ESA: Landscaping SHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE Inspection Type Date Accepted By Electrical 417-4735 Construction- R.W. PW /Engineering 417-4831 Fire 417-4653 Planning 417-4750 Building 417-4815 T:Forms/Building Division/Building Permit CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY& ECONOMIC DEVELOPMENT- BUILDING DIVISION `— 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Page 2 Application Number . . . . . 13-00000829 Date 8/12/13 Application pin number . . . 180050 ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 171.30 171.30 .00 .00 REPORT SALES TAX Plan Check Total .00 .00 .00 .00 on your state excise tax form Grand Total 171.30 171.30 .00 .00 to the City of Port Angeles (Location Code 0502) Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder) T:Forms/Building Division/Building Permit BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS— Building Inspections 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION: Footings Stemwall Foundation Drainage/Downspouts Piers Post Holes(Pole Bldgs.) PLUMBING: Under Floor/Slab Rough-in Water Line(Meter to Bldg) Gas Line Back Flow/Water FINAL Date Accepted b AIR SEAL: Walls Ceiling FRAMING: Joists/Girders/Under Floor Shear Wall/Hold Downs Walls/Roof/Ceiling Drywall(Interior Braced Panel Only) T-Bar INSULATION: Slab Wall/Floor/Ceiling MECHANICAL: Heat Pum /Furnace/FAU/Ducts Rough-in Gas Line Wood Stove/Pellet/Chimney Commercial Hood/Ducts FINAL Date Accepted b MANUFACTURED HOMES: Footing/Slab Blocking&Hold Downs Skirting PLANNING DEPT. Separate Permit#s SEPA: Parkin /Lighting ESA: Landscaping SHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE Inspection Type Date Accepted By Electrical 417-4735 Construction-R.W. PW I Engineering 417-4831 Fire 417-4653 Planning 417-4750 Building 417-4815 T:Forms/Building Division/Building Permit CIT ORT NGELES ' CITY OF For City Use Permit# %3 671 WASH I N G T O N , U . S. Date Received: 7-7<-- 321 <-321 East 51h Street Port Angeles, WA 98362 Date Approved P: 360-417-4817 F: 360-417-4711 permits@cityofpa.us Building Permit Application hzY,l 4rw�* Project Address: 13o 0 L&xttriAs,&-y-\ ?ac-, cal.-S WK �13 6 Main Contact: Phone # 3 Go -'S'011 - CG! E-Mail: Property Name Phone aa1 Owner G I al(AAA Vav►s( 366 Mailing Address Email `zl?oLet"rids eP7 S1 1) Clty state zip Foc-,- fAn elegy ` L"a A 61 X36 3 Contractor Name Phone P'g tt,,-( e,s 36v ,61 7 6 e/S- Mailing Addresif Email 1140( LLOASOU-N\ i� JCke6Gs-AreAS t04�erre_l1 -as -cc,-,t city State zip `moo-•I- dre('"& UJ Acl 9367 Contractor License# Expiration: 05-7 c I-L I 3\ 1 1 Project Value: Zoning: Tax Parcel# Lot# Type of Residential ❑ Commercial Industrial ❑ Public ❑ Permit Demolition ❑ Fire ❑ Repair ❑ Reroof(tear off/lay over) ❑ For the following,fill out both pages of permit application: New Construction ❑ Remodel ❑ Addition ❑ Tenant Improvement ❑ Mechanical Plumbing ❑ Other ❑ Existing Fire Sprinkler System? Maximum height of structure Proposed Bedrooms Proposed Bathrooms Yes ❑ No Project 6C loco gJalk _. Description " I have read and completed the application and know it to be true and correct.I am authorized to apply for this permit. I understand that it is my responsibility to determine what permits are required and to obtain permits prior to working on projects. I understand that the plan review fee is not refundable after plan review has occurred. I understand that I will forfeit the review fee if I cancel or withdraw the application before the permit is issued. I understand that if the permit is not issued within 180 days of receipt,the application will be considered abandoned and the fees forfeit. Date Print Name Signature �`Zy1/3 Residential Structures For Office Use Area Description(SQ FT) Existing Proposed $$value Basement First Floor Second Floor Covered Deck/Porch/Entry Deck Garage Carport Other(describe) Area Totals Commercial Structures For Office Use Area Descriptions(SQ FT) Existing Proposed $$Value Existing Structure(s) Proposed Addition Tenant Improvement? Other work(describe) Area Totals Lot/Site Coverage Calculations Footprint(SQ FT)of all Structures: Lot Size: %Lot Coverage SQ FT Site coverage(all impervious+ %Site Coverage structures Mechanical Fixtures Indicate how many of each type of fixture to be installed or relocated as part of this project. Air Handler Size: # Haz/Non-Haz Piping #of Outlets: Appliance Vent # Heater(Suspended,Floor,Recessed wall) # Boiler/Compressor Size: # Heating/Cooling appliance # repair/alteration Evaporative Cooler(attached,not # Pellet Stove/Wood-burning/Gas # portable) Fireplace/Gas Stove Gas Cook Stove/Misc. Fuel Gas Piping #of Outlets: Ventilation Fan,single duct # Furnace/Heat Pump/ Size: # Ventilation System # Forced Air Unit Plumbing Fixtures Indicate how many of each type of fixture to be installed or relocated Plumbing Traps # Fuel gas piping #of Outlets: Water Heater # Medical gas piping #of Outlets: Water Line # Vent piping # Sewer Line # Industrial waste pretreatment # interceptor Other(describe): T:\BUILDING\APPLICATION FORMS\BUILDING PERMIT 081212.DOCX Plan Review Clallam Transit Propane Dispenser Installation 830 West Lauridsen 1) Tank maybe located within 10' of building, but point of transfer must be 25' from building unless the exterior wall of the building is a one-hour fire wall, in which case it may also beat 10', per NFPA 58, Table 6.5.3 (Attached) 2) Electrical Area Classification shall be per NFPA 58, table 6.22.2.2 (Attached) 3) Dispensing station must meet all provisions of NFPA 58. 6.24 (Attached) 4) All provisions of NFPA 58, 6.25.4 must be met (Attached) 5) Vehicle impact protection must be provided as shown on plans. Com- •_����1- o-�• 20�3 Ken Dubuc, Fire Chief Date GENERAL REQUIREMENTS 311.5.5 Informational use. The use of these symbols SECTION 314 shall be informational only and shall not in any way limit INDOOR DISPLAYS the discretion of the on-scene incident commander. 314.1 General.Indoor displays constructed within any occu- pancy shall comply with Sections 314.2 through 314.4. SECTION 312 314.2 Fixtures and displays.Fixtures and displays of goods VEHICLE IMPACT PROTECTION for sale to the public shall be arranged so as to maintain free, 312.1 General. Vehicle impact protection required by this immediate and unobstructed access to exits as required by code shall be provided by posts that comply with Section Chapter 10. 312.2 or by other approved physical barriers that comply with 314.3 Highly combustible goods. The display of highly Section 312.3. combustible goods, including but not limited to fireworks, 312.2 Posts. Guard posts shall comply with all of the follow- flammable or combustible liquids,liquefied flammable gases, oxidizing materials, pyroxylin plastics and agricultural ing requirements: goods,in main exit access aisles, corridors,covered and open 1. Constructed of steel not less than 4 inches (102 mm) in malls, or within 5 feet (1524 mm) of entrances to exits and diameter and concrete filled. exterior exit doors is prohibited when a fire involving such 2. Spaced not more than 4 feet (1219 mm) between posts goods would rapidly prevent or obstruct egress. on center. 314.4 Vehicles.Liquid-or gas-fueled vehicles, boats or other 3. Set not less than 3 feet (914 mm) deep in a concrete motorcraft shall not be located indoors except as follows: footing of not less than a 15-inch (381 mm) diameter. 1. Batteries are disconnected. 4. Set with the top of the posts not less than 3 feet (914 2. Fuel in fuel tanks does not exceed one-quarter tank or 5 mm) above ground. gallons (19 L) (whichever is least). 5. Located not less than 3 feet (914 mm) from the pro- 3. Fuel tanks and fill openings are closed and sealed to tected object. prevent tampering. 312.3 Other barriers. Physical barriers shall be a minimum 4. Vehicles, boats or other motorcraft equipment are not of 36 inches (914 mm) in height and shall resist a force of fueled or defueled within the building. 12,000 pounds(53 375 N)applied 36 inches(914 mm) above the adjacent ground surface. SECTION 315 GENERAL STORAGE SECTION 313 315.1 General.Storage shall be in accordance with Sections FUELED EQUIPMENT 315.2 through 315.4. 313.1 General. Fueled equipment including, but not limited 315.2 Permit required.A permit for miscellaneous combus- to,motorcycles, mopeds,lawn-care equipment,portable gen- tible storage shall be required as set forth in Section 105.6. erators and portable cooking equipment, shall not be stored, operated or repaired within a building. 315.3 Storage in buildings.Storage of materials in buildings , Exceptions: shall be orderly and stacks shall be stable.Storage of combus- tible materials shall be separated from heaters or heating 1. Buildings or rooms constructed for such use in devices by distance or shielding so that ignition cannot occur. accordance with the International Building Code. 315.3.1 Ceiling clearance.Storage shall be maintained 2 2. Where allowed by Section 3'14. feet (6 10 mm) or more below the ceiling in nonsprinklered 3. Storage of equipment utilized for maintenance pur- areas of buildings or a minimum of 18 inches (457 mm) poses is allowed in approved locations when the below sprinkler head deflectors in sprinklered areas of aggregate fuel capacity of the stored equipment does buildings. not exceed 10 gallons (38 L) and the building is 315.3.2 Means of egress. Combustible materials shall not equipped throughout with an automatic sprinkler be stored in exits or enclosures for stairways and ramps. system installed in accordance with Section 315.3.3 Equipment rooms. Combustible material shall 903.3.1.1. not be stored in boiler rooms,mechanical rooms or electri- 313.1.1 Removal. The fire code official is authorized to cal equipment rooms. require removal of fueled equipment from locations where 315.3.4 Attic, under-floor and concealed spaces. Attic, the presence of such equipment is determined by the fire under-floor and concealed spaces used for storage of com- code official to be hazardous. bustible materials shall be protected on the storage side as 313.2 Group R occupancies. Vehicles powered by flamma- required for 1-hour fire-resistance-rated construction. ble liquids, Class II combustible liquids or compressed flam- Openings shall be protected by assemblies that are self- mable gases shall not be stored within the living space of closing and are of noncombustible construction or solid Group R buildings. 2012 INTERNATIONAL FIRE CODE® 51 ! INSTALLATION OF LP-GAS SYSTEMS 58-33 Table 6.5.3 Distance Between Point of Transfer and (C) Containers of more than 2000 gal(7.6 ms)water capacity Exposures shall be provided with concrete or masonry foundations formed to fit the container contour or, if furnished with Minimum saddles in compliance with Table 6.6.3.3(A), shall be placed Horizontal Distance on flat-topped foundations. Part Exposure ft In (D) Containers of 2000 gal (7.6 in water capacity or less shall be installed either on concrete or masonry foundations ' A Buildings, mobile homes, 10` 3. formed to fit the container contour or in accordance with 1 6.6.3.1(E). recreational vehicles,and I. modular homes with at least (E) Containers of 2000 gal(7.6 m3)water capacity or less and + 1-hour fire-rated wallsb equipped with attached supports complying with Table B Buildings'with other than at 25` 7.6` 6.6.3.3(A)shall be installed on a fire-resistive foundation if the least 1-hour fire-rated wallsb bottoms of the horizontal members of the container saddles, ! C Building wall openings or pits 25` 7.6` runners,or skids are more than 12 in. (300 mm) above grade. j at or below the level of the (F) Containers of 2000 gal (7.6 ms) water capacity or less �`•' point of transfer �(I D Line of adjoining property 25` 7.6` shall not be mounted with the outside bottom of the container that can be built upon shell more than 5 ft(1.5 m) above the surface of the ground. I I E Outdoor places of public 50` 15` (G) Containers of 2000 gal(7.6 ms)water capacity or less and assembly,including container-pump assemblies mounted on a common base com- schoolyards,athletic fields, plying with Table 6.6.3.3(A) shall be placed either on paved { �� and playgrounds surfaces or on concrete pads at ground level within 4 in. F Public ways,including public (102 mm) of ground level. Iil I streets,highways, thoroughfares,and 6.6.3.2 ASME containers that have liquid interconnections sidewalks shall be installed so that the maximum permitted filling level 1 1 From points of transfer in 10 3.1 of each container is at the same elevation. LP Gas dispensing stations 6.6.3.3 Support of Horizontal ASME Containers. and at vehicle fuel dispensers (A) Horizontal ASME containers with attached supports and (2) From other points of 25` 7.6` designed for permanent installation in stationary service shall ;a) transfer be installed in accordance with Table 6.6.3.3(A). !I G Drivewaysd 5 1.5 (B) Horizontal ASME containers of 2000 gal (7.6 m3) or less, H Mainline railroad track 25 7.6 on foundations in their installed condition,shall meet the fol- centerlines lowing:. I Containers'other than those 10 3.1 f being filled (1) Structurally support the containers when subject to dete- riorating { environmental effects including,but not limited J Flammable and Class II 10` 3.1` combustible liquid to, ambient temperature of—40°F to 150°F (-40°C to dispensers and the fill 66°C) or local conditions if outside this range,ultraviolet i I connections of containers rays,radiant heat from fires,and moisture K Flammable and Class II 20 6.1 (2) Be of either noncombustible or self-extinguishing mate- combustible liquid rial(per the definition in NFPA99,Standard forHealth Care I '• containers,aboveground Facilities 3.3.165) j containers,and containers 6.6.3.4 Where a single ASME container complying with jl under groundTable 6.6.3.3(k1) is installed in isolated locations with non- �I fireproofed steel supports resting on concrete pads or foot- 'For the purpose of the table,buildings also include structures such as ings and the outside bottom of the container shell is not tents and box trailers at construction sites. bSee NFPA 251, Standard Methods of Tests of Fire Resistance of Building more than 5 ft(1.5 m) above the ground level,the approval !; of the authority having jurisdiction shall be obtained. Construction and Materials. i I,! `See 6.5.4.4. 6.6.3.5 The part of an ASME container in contact with !� dNot applicable to driveways and points of transfer at vehicle fuel dis- saddles or foundations or masonry shall be coated or pro- II pensers. tected to minimize corrosion. `Not applicable to filling connections at the storage container or to I .I ' dispensing vehicle fuel dispenser units of 2000 gal (7.6 m3) water 6.6.3.6 In locations where the monthly maximum depth of I' capacity or less when used for filling containers not mounted on ve- snow accumulation,as determined from the National Weather hicles. Service or other published statistics,is more than the height of ! ,� `NFPA 30,Flammable and Combustible Liquids Code,defines these as fol- aboveground containers, excluding the dome cover, the fol- lows: Flammable liquids include those having flash point below q g a P lowing requirements shall apply: 100°F (37.8°C) and having a vapor pressure not exceeding 40 psia (276 kPa) at 100°F (37.8°C). Class II combustible liquids include (1) A`stake or other marking shall be installed higher than the ' those having a flash point at or above 100°F(37.8°C)and below 140°F average snow cover depths,up to a height of 15 ft(4.6 m). (60°C). (2) The container shall be installed to prevent its movement i resulting from snow accumulation. !Ii�l 2011 Edition �Il I ij 58-48 LIQUEFIED PETROLEUM GAS CODE Table 6.21.3.6 Minimum Separation Distances Between 6.21.6 Installation of Waterbath Vaporizers. Direct-Fired Vaporizers and Exposures 6.21.6.1 If a waterbath vaporizer is electrically heated and all Minimum Distance electrical equipment is designed for Class I, Group D loca- 1' aired i Re tions, the unit shall be treated as an indirect-fired vaporizer Required and shall be installed in accordance with 6.21.2. I I Exposure ft In 6.21.6.2 All other waterbath vaporizers shall be treated as Container 10 3.0 direct-fired vaporizers and shall be installed in accordance Container shutoff valves 15 4.6wi th 6.21.3. Point of transfer 15 4.6 6.21.7 Installation of Electric Vaporizers.Electric vaporizers, Nearest important building or 25 7.6 whether direct immersion or indirect immersion, shall be group of buildings or line of treated as indirect-fired and shall be installed in accordance adjoining property that can be built upon with 6.21.2. i. Nearest Chapter 10 building or 10 3.0 6.21.8 Installation of Gas-Air Mixers. room housing gas-air mixer Ipi Cabinet housing gas-air mixer 0 0 6.21.8.1 Piping and equipment installed with a gas-air mixer outdoors shall comply with 6.9.1,6.9.3,and 6.14. Note:Do not apply distances to the building in which a direct-fired 6.21.8.2 Where used without a vaporizer, a mixer shall be vaporizer is installed. installed outdoors or in a building complying with Chapter 10. 6.21.8.3 Where used with an indirect-fired vaporizer,a mixer I Table 6.21.4.1 Minimum Separation Between Tank Heaters shall be installed as follows: and Exposures (1) In an outdoor location f I Minimum Distance (2) In the same compartment or room with the vaporizer (3) In a building complying with Chapter 10 i! Container Water Capacity Required (4) In a location that is both remote from the vaporizer and III in accordance with 6.21.2 gat ms ft m 6.21.8.4 Where used with a direct fired vaporizer, a mixer �I 5500 51.9 10 3.0 shall be installed as follows: „I 501-2,000 >1.9-7.6 25 7.6 2,001-30,000 >7.6-114 50 15.0 (1) With a listed or approved mixer in a common cabinet with 30,001-70,000 >114-265 75 23.0 the vaporizer outdoors in accordance with 6.21.3.6 70,001-90,000 >265-341 100 30.5 (2) Outdoors on a common skid with the vaporizer in accor- I;' 90,001-120,000 >341-454 125 38.1 dance with 6.21.3 (3) Adjacent to the vaporizer to which it is connected in ac- cordance with 6.21.3 (4) In a building complying with Chapter 10 without a direct- 6.21.5 Installation of Vaporizing Burners. fired vaporizer in the same room 6.21.5.1 Vaporizing burners shall be installed outside of build- 6.22 Ignition Source Control. mgs. 6.22.1 Scope. I: 6.21.5.2 The minimum distance between any container and a vaporizing burner shall be in accordance with Table 6.21.5.2. 6.22.1.1 -This section shall apply to the minimization of igni- 1 y 6.21.5.3 Manually operated positive shutoff valves shall be lion of flammable LP-Gas-air mixtures resulting from the nor- located at the containers to shut off all flow to the vaporizing mal or accidental release of nominal quantities of liquid or II burners. vapor from LP-Gas systems installed and operated in accor- dance with this code. 6.22.1.2*The installation of lightning protection equipment Table 6.21.5.2 Minimum Separation Distance Between shall not be required on LP-Gas storage containers. Containers and Vaporizing Burners 6.22.1.3* Grounding and bonding shall not be required on LP-Gas systems. i; Minimum Container Water Capacity Distance Required 6.22.2 Electrical Equipment. r gal ms ft In 6.22.2.1 Electrical equipment and wiring installed in unclas- sified areas shall be in accordance with NFPA 70,National Elec �I 5500 51.9 10 3.0 trical Code. 501-2000 1.9-7.6 25 7.6 6.22.2.2*The extent of electrically classified areas shall be in >2000 >7.6 50 15.0 accordance with Table 6.22.2.2. I � I' 2011 Edition �i:i , INSTALLATION OF LP-GAS SYSTEMS 58-49 Table 6.22.2.2 Electrical Area Classification Equipment Shall Be Approved for Compliance with NFPA 70,National I Electrical Code,Class P, (i Part Location Extent of Classified Area' Group Db A Unrefrigerated containers other than Within 15 ft(4.6 m)in all directions from connections, Division 2 cylinders and ASME vertical except connections otherwise covered in this table ; containers of less than 1000 lb (454 kg)water capacity B Refrigerated storage containers Within 15 ft(4.6 m)in all directions from connections Division 2 otherwise covered in this table i Area inside dike to the level of the top of the dike Division 2 ? I i C` Tank vehicle and tank car loading and Within 5 ft(1.5 m)in all directions from connections Division 1 unloading regularly made or disconnected for product transfer wl Beyond 5 ft(1.5 m)but within 15 ft(4.6 m)in all directions Division 2 4�i : from a point where connections are regularly made or i 1. disconnected and within the cylindrical volume between 3 i. the horizontal equator of the sphere and grade 1 D Gauge vent openings other than those Within 5 ft(1.5 m)in all directions from point of discharge Division 1 on cylinders and ASME vertical containers of less than 1000 lb (454 kg)water capacity Beyond 5 ft(1.5 m)but within 15 ft(4.6 m)in all directions Division 2 from point of discharge E Relief device discharge other than those Within direct path of discharge Fixed electrical on cylinders and ASME vertical equipment not containers of less than 1000 lb permitted to be 454 k )water ca !` ( g capacity and P ty installed vaporizers F` Pumps,vapor compressors,gas—air i ;I mixers and vaporizers(other than j direct-fired or indirect-fired with an I attached or adjacent gas-fired heat 1 source) Indoors without ventilation Entire room and any adjacent room not separated by a Division 1 i gastight partition !j Within 15 ft(4.6 m)of the exterior side of any exterior wall Division 2 { or roof that is not vaportight or within 15 ft(4.6 m)of any exterior opening I `! Indoors with ventilation Entire room and any adjacent room not separated by a Division 2 (ilii ii gastight partition Outdoors in open air at or above grade Within 15 ft(4.6 m)in all directions from this equipment Division 2 and within the cylindrical volume between the horizontal R equator of the sphere and grade ii illi' I, G Vehicle fuel dispenser Entire space within dispenser enclosure,and 18 in. Division 1 ii I, (460 mm)horizontally from enclosure exterior up to an i� ! elevation 4 ft(1.2 m)above dispenser base;entire pit or open space beneath dispenser Up to 18 in. (460 mm)above ground within 20 ft(6.1 m) Division 2 horizontally from any edge of enclosure(Note:For pits within this area,see part H of this table.) { i;ll'q H Pits or trenches containing or located beneath LP-Gas valves,pumps,vapor compressors,regulators,and similar i iIII equipment i' (continues) !' j 1t 2011 Edition !jyl INSTALLATION OF LP-GAS SYSTEMS 58-53 6.23.7.9 Appliances shall be located so that a fire at any appli- 6.24.3.2 Vehicle fuel dispensers and dispensing stations shall ante will not block egress of persons from the vehicle. not be located within a building,except as allowed in Chapter 10. 6.23.7.10 A permanent caution plate shall be provided, af- 6.24.3.3 Where a vehicle fuel dispenser is installed under a fixed to either the appliance or the vehicle outside of any en- weather shelter or canopy,the area shall be ventilated and shall closure and adjacent to the container(s),and shall include the not be enclosed for more than 50 percent of its perimeter. following items: CAUTION: 6.24.3.4 Control for the pump used to transfer LP-Gas through the unit into containers shall be provided at the de- (1) Be sure all appliance valves are closed before opening con- vice in order to minimize the possibility of leakage or acciden- j tainer valve. tal discharge. (2) Connections at the appliances,regulators,and containers shall be checked periodically for leaks with soapy water or 6.24.3.5 An excess-flow check valve or a differential back its equivalent. pressure valve shall be installed in or on the dispenser at the (3) Never use a match or flame to check for leaks. point at which the dispenser hose is connected to the liquid (4) Container valves shall be closed when equipment is not in P P enserIj use. piping. �( 6.23.8 General Precautions. Mobile units containing hot 6.24.3.6 Piping and the dispensing hose shall be provided plates and other cooking equipment,including mobile kitch- with hydrostatic relief valves in accordance with Section 6.13. I ens and catering vehicles,shall be provided with at least one approved portable fire extinguisher rated in accordance with 6.24.3.7 Protection against trespassing and tampering shall NFPA 10,Standard for Portable Fire Extinguishers,at not less than be in accordance with 6.18.4. 10-B:C. Where fire extinguishers have more than one letter classification,they can be considered as meeting the require- 6.24.3.8 The container liquid withdrawal opening used with i} ments of each letter class. vehicle fuel dispensers and dispensing stations shall be equipped with one of the following: 6.23.9 Parking,Servicing,and Repair. E (1) An internal valve fitted for remote closure and automatic 6.23.9.1 Where vehicles with LP-Gas fuel systems used for shutoff using thermal (fire) actuation purposes other than propulsion are parked, serviced, or re- (2) A positive shutoff valve that is located as close to the con- Jf paired inside buildings,the requirements of 6.23.9.2 through twiner as practical in combination with an excess-flow Ii 6.23.9.4 shall apply. valve installed in the container,plus an emergency shutoff 6.23.9.2 The fuel system shall be leak-free,and the container(s) valve,that is fitted for remote closure and installed down- ` shall not be filled beyond the limits specified in Chapter 7. stream in the line as close as practical to the positive shut- I( 6.23.9.3 The container shutoff valve shall be closed, except off valve that the container shutoff valve shall not be required to be 6.24.3.9 An identified and accessible remote emergency i closed when fuel is required for test or repair. shutoff device for either the internal valve or the emergency 6.23.9.4 The vehicle shall not be parked near sources of heat, shutoff valve required by 6.24.3.8(1) or (2) shall be installed open flames, or similar sources of ignition, or near unventi- not less than 3 ft (1 m) or more than 100 ft (30 m) from the latedP�its. liquid transfer point. 6.23.9.5 Vehicles having containers with water capacities larger 6.24.3.10 Emergency shutoff valves and internal valves that than 300 gal(1.1 ma)shall comply with the requirements of Sec- are fitted for remote closure as required in this section shall be tion 9.7. tested annually for proper operation. 6.24 Vehicle Fuel Dispenser and Dispensing Stations. 6.24.3.11 A manual shutoff valve and an excess-flow check 6.24.1 Application. valve shall be located in the liquid line between the pump and the dispenser inlet where the dispensing device is installed at a 6.24.1.1 Section 6.24 includes the location,installation,and remote location and is not part of a complete storage and operation of vehicle fuel dispensers and dispensing stations. dispensing unit mounted on a common base. 6.24.1.2 The provisions of Sections 6.2 and 6.3, as modified 6.24.3.12 All dispensers either shall be installed on a con- by Section 6.24,shall apply. trete foundation or shall be part of a complete storage and j 6.24.2 Location. dispensing unit mounted on a common base and installed in 6.24.2.1 Location of vehicle fuel dispensers and dispensing accordance with 6.6.3.1(G). Protection against physical dam- stations shall be in accordance with Table 6.5.3. age shall be provided for dispensers. 6.24.2.2 Vehicle fuel dispensers and dispensing stations shall 6.24.3_.13 A listed quick-acting shutoff valve shall be installed be located away from pits in accordance with Table 6.5.3,with at the discharge end of the transfer hose. II no drains or blow-offs from the unit directed toward or within 6.24.3.14 An identified and accessible switch or circuit breaker 15 ft(4.6 m) of a sewer system's opening. shall be installed at a location not less than 20 ft(6.1 m)or more 6.24.3 General Installation Provisions. than 100 ft(30.5 m)from the dispensing device(s)to shut off the 6.24.3.1 Vehicle fuel dispensers and dispensing stations shall power in the event of a fire,an accident,or other emergency. be installed in accordance with the manufacturer's installa- 6.24.3.15 The markings for the switches or breakers shall be tion instructions. visible at the point of liquid transfer. 2011 Edition 58-54 LIQUEFIED PETROLEUM GAS CODE { 6.24.4 Installation of Vehicle Fuel Dispensers. 6.25.4.2 Each industrial plant, bulk plant, and distributing 6.24.4.1 Hose shall comply with the following: point shall be provided with at least one approved portable fire extinguisher having a minimum capacity of 18 lb (8.2 kg) (1) Hose length shall not exceed 18 ft (5.5 m) unless ap- of dry chemical with a B:C rating. Where fire extinguishers I proved by the authority having jurisdiction. have more than one letter classification, they shall be consid- (2) All hose shall be listed. ered to.satisfy the requirements of each letter class. (3) When not in use, hose shall be secured to protect them j I 6.25.4.3* LP-Gas fires shall not be extinguished until the i from damage. � 6.24.4.2 A listed emergency breakaway device complying with source of the burning gas has been shut off. ! ANSI/UL 567,Standard Pipe Connectors for Flammable and Com- 6.25.4.4 Emergency controls shall be conspicuously marked, i' bustible Liquids and LP-Gas, and designed to retain liquid on and the controls shall be located so as to be readily accessible both sides of the breakaway point,or other devices affording in emergencies. equivalent protection approved by the authority having juris- 6.25.5 Special Protection. diction,shall be installed. 6.24.4.3 Dispensing devices for LP-Gas shall be located as 6.25.5.1* If insulation is used, it shall be capable of limiting follows: the container temperature to not over 800°F (427°C) for a minimum of 50 minutes as determined by test,with insulation IIS. (1) Conventional systems shall be at least 10 ft (3.0 m) from applied to a steel plate and subjected to a test flame applied any dispensing device for Class I liquids. substantially over the area of the test plate. (2) Low-emission transfer systems in accordance with I' Sec- 6.25.5.2 The insulations tem shall be inherently resistant to tion 6.26 shall be at least 5 ft (1.5 m) from any dispens- � y ing device for Class I liquids. weathering and the action of hose streams. 6.25.5.3 If mounding is utilized,the provisions of 6.6.6.3 shall I' 6.25 Fine Protection. g� be required. 6.25.1 Application.Section 6.25 applies to fire protection for industrial plants,bulk plants,and dispensing stations. 6.25.5.4 If burial is utilized,the provisions of 6.6.6.1 shall be 6.25.2*Planning. required. 6.25.2.1 The planning for the response to incidents includ- 6.25.6 Water Spray Systems. ing the inadvertent release of LP-Gas,fire,or security breach 6.25.6.1 If water spray fixed systems and monitors are used, , shall be coordinated with local emergency response agencies. they shall comply with NFPA 15,Standard for Water Spray Fixed ` 6.25.2.2 Planning shall include consideration of the safety of Systems for Fire Protection. 'II emergency personnel,workers,and the public. 6.25.6.2 Where water spray fixed systems and monitors are 6.25.3*Protection of ASME Containers. used,they shall be automatically actuated by fire-responsive 6.25.3.1 Fire protection shall be provided.for installations devices and shall also have a capability for manual actuation. with an aggregate water capacity of more than 4000 gal 6.25.6.3 Where monitor nozzles are used, they shall be 10- (15.1 o-(15.1 ms) and for ASME containers on roofs. cated and arranged so that all container surfaces that can be 6.25.3.2 The modes of fire protection shall be specified in a exposed to fire are wetted. written fire safety analysis for new installations,and for exist- 6.26 Alternate Provisions for Installation of ASME Containers. ing installations that have an aggregate water capacity of more than 4000 gal (15.1 ms), and for ASME containers on roofs. 6.26.1 Application.Section 6.26 shall apply to alternate provi- Existing installation shall comply with this requirement within sions for the location and installation of ASME containers that 2 years of the effective date of this code. incorporate the use of redundant fail-safe product control measures and low-emission transfer concepts for the purpose 6.25.3.3 The fire safety analysis shall be submitted by the of enhancing safety and to mitigate distance and special pro- owner, operator, or their designee, to the authority having tection requirements. jurisdiction and local emergency responders. 6.25.3.4 The fire safety analysis shall be updated when the 6.26.2 Spacing Requirements for Underground and Mounded storage capacity or transfer system is modified. ASME Containers. 6.25.3.5 The fire safety analysis shall be an evaluation of the 6.26.2.1 Where all the provisions of Section 6.26 are com- total product control system,such as the emergency shutoff and plied with, the minimum distances from important buildings . internal valves equipped for remote closure and automatic shut- and the line of adjoining property that can be built upon to off using thermal (fire)actuation,pullaway protection where in- underground and mounded ASME containers of 2001 gal stalled,and the optional requirements of Section 6.26. through 30,000 gal (7.6 m through 114 m ) water capacity shall be reduced to 10 ft(3.0 m). 6.25.3.6 If in the preparation for the fire safety analysis it is determined that a hazard to adjacent structures exists that ex- 6.26.2.2 Distances for all underground and mounded ASME ceeds the protection provided by the provisions of this code, containers shall be measured from the container surface. special protection shall be provided in accordance with 6.25.5. 6.26.2.3 No part of an underground or mounded ASME con- 6.25.4 Other Protection Requirements. tainer shall be less than 10 ft (3 m) from a building or line of 6.25.4.1 Roadways or other means of access for emergency adjoining property that can be built upon. equipment, such as fire department apparatus, shall be pro- 6.26.3 ASME Container Appurtenances. The provisions in vided. 6.26.3.1 through 6.26.3.5 shall be required for ASME contain- is f 2011 Edition �I r . , a ca 47 10 90- CL Q. o` 4r Z' F a v o o C4' a, �t"T A\ ' :I.t�S i�IEjk: DEPT Yo O � , �PPp-pig vJ,-r►-! 1 T yt