Loading...
HomeMy WebLinkAbout400 N Francis St - Building tS ~""" CITY OF PORT ANGELES PUBLIC WORKS - BUILDING DIVISION 321 EAST 5TH STREET, PORT ANGELES, W A 98362 BUILDING PERMIT OWNER/APPLICANT City of Port Angeles 321 E. 5th Street Port Angeles, WA 98362 360/417-4815 T: S: ISSUED: 10/04/2001 PERMIT NO: 13024 PROPERTY LOCATION 400 FRANCIS N Lot: 8-10 Block: 32 D Long Legal Subdivision: N.R.Smith Parcel No: 063000513235000 CONTRACTOR LANDSCAPING BY COCKBURN 4950 SEOUIM DUNGNESS WAY Port Angeles, WA 98382 360/681-0644 PROJECT INFO Project Value: $6,000.00 Project Type: BACKFLOW VALVE Occupancy Type: Occupancy Group: Construction Type: Zoning Use: ARCHITECT N/A , 98360-0000 360/000-0000 SFD Units: SFD SO FT: o o Commercial: Industrial: Garage: o o o .J::' \.; Q "2 MFD Units: MFD SO FT: o o PROJECT NOTES install back flow to irriagation reciept # 8141 FEES ASSESSMENT Building Permit: Plan Check: State Surcharge: House Moving: Manufactured Home: Sign: Plumbing: Mechanical: Radon: $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $27.00 $0.00 $0.00 't ) ~ < / r If. .. Misc Fee 1: Misc Fee 2: Misc Fee 3: $0.00 $0.00 $0.00 TOTAL FEE: AMOUNT PAID: BALANCE DUE: $27.00 $27.00 $0.00 Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work Is suspended or abandoned for a period of 180 days after the work as commenced, or if required Inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to ive authority t violate or cancel the provisions of any state or local law regulating construction or the performance of construct' . , Date /(:; Si9nature of Owner (if owner is builder) li ~ BUILDING PERMIT CITY OF PORT ANGELES PUBLIC WORKS - BUILDING DIVISION 321 EAST 5TH STREET, PORT ANGELES, WA 98362 OWNER/APPLICANT City of Port Angeles 321 E. 5th Street Port Angeles, WA 98362 360/417-4815 T: ISSUED: 7/26/2001 PERMIT NO: 12823 PROPERTY LOCATION 400 FRANCIS N Lot: 8-10 Block: 32 D Long Legal Subdivision: N.R.Smith S: Parcel No: 063000513235000 CONTRACTOR PRIMO CONSTRUCTION 970 CARLSBORG RD. Port Angeles, WA 99360 360/683-5447 ARCHITECT N/A , 98360-0000 360/000-0000 PROJECT INFO Project Value: $49,587.00 Project Type: PAVILLlON Occupancy Type: COMMERCIAL Occupancy Group: Construction Type: Zoning Use: SFD Units: SFD sa FT: o o Commercial: Industrial: Garage: o o o ....t ,:: C' ~ ., 'I .., ~\ c- ? r !f' MFD Units: MFD sa FT: o o PROJECT NOTES construct a 385 sJ. viewing pavillion FEES ASSESSMENT Building Permit: $644.25 Mise Fee 1: $0.00 Plan Check: $386.55 Mise Fee 2: $0.00 State Surcharge: $4.50 Mise Fee 3: $0.00 House Moving: $0.00 Manufactured Home: $0.00 Sign: $0.00 TOTAL FEE: $1,035.30 Plumbing: $0.00 AMOUNT PAID: $1,035.30 Mechanical: $0.00 BALANCE DUE: $0.00 Radon: $0.00 Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Signature of Contractor or Authorized Agent Date Signature of Owner (if owner is builder) Date BUll..DING PERMIT INSPECTION RECORD CALL 417-4815 FOR BUILDING INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULA TE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCA nON. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE r t-'{~ 3 INSPECTlOI'Ii TYPE DATE ACCEPTED COMMENTS I YES I NO FOUNDATION: i en", ,0L~'Z'<. g .y:-u \ t..-'irt rov>.Jl), $'7f1L _-0K'-~f2.cpf~L.~-M- FooTTNGS 1-'Z.~0\ l"-v: II (J -CJ(~ "i3f2.2/oi -Ll(-+ WALLS I a.-f, -01 L-l.i-\ FOUNDATION DRAINAGE ELECTRICAL (LIGHT DEPT) SEPARATE PERMIT: # ROUGH-IN I I I PLUMBING UNDER FLOOR I SLAB ROUGH-IN WATER LINE GAS LINE BACK FLOW I WATER AIR SEAL WALLS I I I CEILING I T T FRAMING JOISTS I GIRDERS SHEAR WALL WALLS I ROOF / CEILING DRYWALL I-BAR INSULATION SLAB I I I WALL I FLOOR / CEILING T I I MECHANICAL HEAT PUMP WQODSTOVE I PELLET/CHIMNEY I INSERT HOODIDUCTS PW UTILITIES I SITE WORK (Engineering Division) SEPARATE PERMIT #'s: WATERLINE I METER SEWER CONNECTION SANITARY STORM PLANNING DEPT. SEPARATE PERMIT #'s SEPA: PARKING/LIGHTING ESA: LANDSCAPING SHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCYIUSE RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED YES NO ELECTRICAL - LIGHT DEPT. 417-4735 ELECTRICAL LIGHT DEPT CONSTRUCTION R.W./ PWI CONSTRUCTION - R.W. ENGINEERING 417-4807 PW I ENGINEERING FIRE 417-4653 FIRE DEPT. PLANNING DEPT. 417.4750 PLANNING DEPT. BUILDING 417-4815 -'775<:. 02- / .F;Zj: BUILDING C:\APPL.WPD rl .~. CITV'Y'PORT ANGELES PUBLIC WORKS DEU~MENT ACCOUNT PERMIT ACCOUNT DOLLAR NAME NUMBER NUMBER AMOUNT Surcharge ($4.50) } 2.. V2.'3 001.2291000 -'7<', s-o D.R.A. Fees Plus Interest 001.2392000 Burning Permit Fee 600.32290014 Fire Inspect/Permit Fee 600.34220015 Fire Sprinkler Plan Review Fee 600.34220016 Construction I -Z li'2- "'; 420.32210017 {~ 411 . ?-.~ Plumbing 420.32210018 Mechanical 420.32210019 Sign 711.32210020 Clear/Grade Permit 711.32210021 House Moving 711.32210033 Sidewalk/Driveway/Curb Permit/Right of Way Permit 711.32240011 Publications 711.34150000 Blueprints-Aerial 711.34320000 Administration Cost (5%) 711.34320010 Plan Check Fee I 2-1S2. '3 420.34583000 ~ ~(o..::.S- Engineering Service Fees 711.34895000 MO TOTAL 001.1111000 ~'5 ."'0 Street/Alley Restoration 752.32210032 Storm Drain/Tap 752.34490010 S/W Co-Op 752.36990000 ~ TFIJHD , TOTAL 102.11110000 ... .... </ EI:ctrical Permits/Inspections I 911.32210028 ! .;:4, 8KlN I TOTAL 401.1111000 PBIA ': 650.2319200 . I . TOTAL 660.1111000 , . ~IaJlrtPUND , TOTAL 310.1111000 . --- , 715.39510010 MDI TOTAL 314.1111000 Hot Tap (watermain) 753.34340023 F.H. Install/Meter 753.34340024 W/M Installation 753.34340025 Water System Development Charge 753.34480010 i),. ;< .... . . TOTAL 402.1111000q Sanitary Sewer Permit 754.32210029 Sanitary Sewer Tap/Cap or MH Tap 754.34350018 Sewer System Development Charge 754.34350024 UUD 215/Equivalent Service Connection Fee 782.34350025 ~ ... .... ...... . 402.1111000 .' 755.34370030 ~ < . ,< .' 404.11110000 I "'\'7 ...... ... 'i."" ~/. " .. RECEIPT# 7363 \rrlo3.s-.3a /M-vr, T,e'/1-v'Ct:5' ('--"'--/ /J./ / ~ Fill-IN COMPLETELY - TOTAL EACH FUND AND GRAND TOTAL {!./TY 01 . ' C-IS ;;J,/07-072<j G\Gm"p\AoctlFocm,\R"Rec\P"b-Wk Last Revised June 2001 s ~~ 2/-07.07 BUILDING PERMIT - APPLICATION ()<'-2/A'j r<--! v~' C'I L> /",;.- '" .... The Building Permit - Pre-applicatlon 1IIIISt be jUhd (Jill cOmpletely. Please type or print in ink. If you have any questioDl, please caB 417-4815 FOR omCIAL USE ONLY: Dale Roc.: PermiU: Dab:~ Dale _: Applicant and/or Agent:-P'l' MD T N C. Owner: r-' ; r y vP F' /) ~ t A N~ e...t e.S Address: :5 ::L I c -S- City: Po e T ArchitectlEngineer: Te e l"\ c.. PI t:.h.r\a ~s. Contractor '? , \ ~o License #: Address: '51 0 CA R..lS bnl'l..<:?, City: I t.... I Phone: Phone: A l'i 1 LIe." Phone: 6%1 ~-<('17 L/I) - 7'1S-S'? Zip: '7<;!3 /, Z- ~//- 8'6~-? Phone: &:i' -54 4 '7 ~ Zip: <::; 'l' '?13''Z- W'~ONlNG: ? is P Subdivision: - S ( Credit Card Holder Name: Oty: Esp. Date: Exp: , "'^-- VISA MC TYPE OF WORK: o Residential )(New Constr. 0 Re-roof o Multi-family 0 Addition 0 Move )f Commen:ia1 0 Remodel 0 Demolition o Repair 0 Sign BRIEF DESCRIPI'ION OF THE PROJEer: o Woodstove o Garage o Deck o lJ,eL<) SlZElVALUATION: '" S '6';'- SF. @$ '-I't 5"b? ;SF. = $ , SF. @ $ (SF. = $ SF.@$ fSF. = $ . TOTAL VALUATION $ PAUl I ~ 0,",- COMMERClALfRESIDENTIAL: Occupancy Group: ~ Occupant Load: ;?-b Construction Type: V IV No. of Stories: , Lot Size: 11;"J;l.<;-b %LotCoverage:.k.s... n.....1"7h % Existing Lot Coverage: 0 (sq. ft. + Proposed Lot Coverage: '3 'i?s- (sq. ft. = TOTAL LOT COVERAGE: 3 8's- (sq.ft I PLANNING USE ONLY: APPROVALS: PLAN Notes: BLDG. DPW FIRE ESAlWet1and(s): 0 Yes 0 No SEPA Checklist required? 0 Yes 0 No Other: ~ BUILDING APPLICATION SUBMrlTAL: Y(J/u applkDtlDn ad sile pllln 1IIIISt be J1lkd (Jut cmrrpletdy I(J be aa:epted f(Jr review. The Building Division can provide you with more detailed information on the application and plan submittal requirements. BUILDING PERMIT APPLICATION SUBMlTl'AL: Your completed application, site plan (for additions) and building construction plans are to be submitted to the Building Division. VALUATION OF CONSTRUCI'ION: In all cases, a va1uation amount must be entered by the applicant This figure will be reviewed and may be revised by the Building Div. to comply with cum:nt fee schedules. Contact the Permit Coordinator at 417-481 S for assistance. PLAN CHECK FEE: Your plan check fee is due at the time the building permit application and construction plans &resubmitted. All other pennit fees are due at the time of permit issuance. EXPIRATION OF PLAN REVIEW: Ifno permit is issued within 180 day. of the date of application, this application wiD eIpire by limitations. The Building Official can extend the time for action by the applicant up to 180 days, on written request by the applicant (see Section 107.4 of the Uniform Building Code, current edition). No application can be extended more than once. / hereby certify that / have read and examined this application and know the same to be true and correct, and / am authorized to apply for this permit. I understand it is not the City's legal responsibility to tktermine what permits cue required; it remains the applicant's responsibility to tktermine what permits are required and to obtain such. ~, / / PW-IIOU3(revSJOII Applicant: .# ~ ~/ Date: 6'/::< d~v . LOCATION: NORTH END OF FRANCIS STREET. THE PROJECT IS LOCATED IN A PORTION OF THE SOUTHWEST QUARTER OF SECTION 2. TOWNSHIP 30 NORTH. RANGE 6 WEST, W1LLAMEflE MERIDIAN. LOT SIZE: 2.6ACRES ZONE: PUBUC BUILDINGS AND PARKS (PBP) VIFW PAVILION: OCCUPANCY B TYPE OF CONSTRUCTION VN BUILDING AREA 385 SQ. FT. OCCUPANCY LOAD 26 STRUCruRAl DATA: ROOF DESIGN 25 PSF (SNOW) FLOOR DESI GN 100 PSF SESIMIC ZONE 3 WIND SPEED & EXPOSURE 80 MFti. EXP. C SOIL BEARING CAPAOTY 1,000 PSF PARKING: STANDARD 9X18 1 0 STAlLS ACCESSIBLE 9X18 2 STAllS .-- TOTAl 12 STAllS CITY OF PORT ANGELES DEPARTMENT OF PUBLIC WORKS . . . . INSPECTION REPORT . . . REQUEST: Date '7. 2:/ }/ Time Location of Work to be inspected ~&e --C~, l:t ,/ 1 ;::..~,-~"r . ~- Name of person requesting inspection Address of person requesting inspection Type of I~tion (circle appropriate one): Sew~/ FO~': Framing Chimney Plumbing Final Sewer Excav. Other \ '--~~-~'..~'- . /' . ./ ..-1.- .' Received by 1"':7" (phone. person) Phone No. Permit No. ,.;, ?2."'':!. T ( .. INSPECTION NOTES: Inspected: Date 7 - z V ()/ Remarks: Time By I~ / / je:: RESTORATION REQUiRED...... YES NO SURFACE RESTORATION: SURFACE TYPE: 0 Unimproved DGravel 0 Asphalt 0 PCC o Other o Repaired by City o Repaired by Permittee o No Damage Found Work Order # o COMPLETE o INCOMPLETE (Continue on reverse side if necessary) STREET SUPERINTENDENT (DATE) CITY OF PORT ANGELES DEPARTMENT OF PUBLIC WORKS . . . . . . INSPECTION REPORT. .... REQUEST: Time Received by [ ~ i 6'G ~CU1l>L;" :j';-,) J(~,,~. ) ~ 'r- ,. . r" ", .~ person) ( . / -;i:-.,L. Date /-7 (~'. - ,......". Location of Work to be inspected Name of person requesting inspection Address of person requesting inspection Phone No. Type of Inspection (circle appropriate one): Permit No. Sewer (Foundation. Framing Chimney Plumbing Final Sewer Excav. Other I,d /0 t . '" .... < (1,.- ~ 'Z..?2.3: ~/:J INSPECTION NOTES: Inspected: Date f?' - t - (Jf Remarks: Time By (!J,~ RESTORATION REQUiRED...... YES NO 'I' i ~., ! ' r"~ /M '\ SURFACE RESTORATION: SURFACE TYPE: D Unimproved D Gravel D Asphalt D PCC D Other D Repaired by City [] Repaired by Permittee D No Damage Found Work Order # D COMPLETE D INCOMPLETE (Continue on reverse side if necessary) STREET SUPERINTENDENT (DATE) CITY OF PORT ANGELES DEPARTMENT OF PUBLIC WORKS . . . . . . INSPECTION REPORT. . . . . . REQUEST: Date g-- ~g- -01 Time Location of Work to be inspected ~CJ Name of person requesting inspection Address of person requesting inspection Type of Inspl;!C 'on (circle appropriate one): / " '\ sew~~"/~r~ming Chimney Plumbing INSPEcT;C:~ /.P;E; , Inspected: Date J:(" I Time Remarks: Received by (phone, person) ~~(!(S Phone No. Permit No. Final Sewer Excav. Other t2-1f2:> + By ,1- I " ) I' " RESTORATION REQUIRED . . . . .. YES NO SURFACE RESTORATION: SURFACE TYPE: 0 Unimproved 0 Gravel 0 Asphalt 0 PCC o Other o Repaired by City o Repaired by Permittee o No Damage Found Work Order # o COMPLETE o INCOMPLETE (Continue on reverse side if necessary) STREET SUPERINTENDENT (DATE) CITY OF PORT ANGELES DEPARTMENT OF PUBLIC WORKS . . . . . INSPECTION REPORT. .... REQUEST: Date R>-2o- C) , Time 7: So 19vt'\ Received by rrrcCl ,- c::>' '11 k r{A,)vL c. S. ,OJI ~2 () l a.. I J ~ vvt,O RL/ (phone, person) Location of Work to be inspected Name of person requesting inspection Address of person requesting inspection Type of Inspection (circle appropriate one): (p <AS' f- Phone No. Permit No. /2&>25 Chimney Plumbing Final Sewer Excav. Other f e, tcF INSPECTION NOTES: ; ...., ,,~-:~:~..;."~ ,....'~.l Inspected: Date r {,L,/' -," ( Remarks: ,xV Time By S /tiI /'3;;: .'~7t7 &,(A ( I: (....- . _ RESTORATION REQUIRED . . . . .. YES NO Atv\ SURFACE RESTORATION: SURFACE TYPE: 0 Unimproved 0 Gravel 0 Asphalt 0 PCC o Other o Repaired by City [] Repaired by Permittee o No Damage Found Work Order # o COMPLETE o INCOMPLETE (Continue on reverse side if necessary) STREET SUPERINTENDENT (DATE) CITY OF PORT ANGELES DEPARTMENT OF PUBLIC WORKS . . . . INSPECTION REPORT. . . . . . . . REQUE@T: . Date -7.1--0 ( Received by Z;tf fjjl/C: \ f!-tr /", 'I' (If 0 (J'11:rh e9. person) Time Location of Work to be inspectedftteJ Name of person requesting inspection Address of person requesting inspection Type of Inspection (circle appropriate one): Sewer( Foundation') Framing Chimney , i, Cvl.<1. IU"\f.,C INSPECTION N~ES: Inspected: Date - 22 --61 Remarks: Phone No. Permit No. Plumbing Final Sewer Excav. Other /282-<:" Time By ~ d~-> ('J f: ~ "'-~/JDIfTI()~ RESTORATION REQUIRED. . . . .. YES NO 1-/V>p ~ '1 (0 A K SURFACE RESTORATION: SURFACE TYPE: 0 Unimproved 0 Gravel 0 Asphalt 0 pcc o Other o Repaired by City [] Repaired by Permittee o No Damage Found Work Order # o COMPLETE o INCOMPLETE (Continue on reverse side if necessary) STREET SUPERINTENDENT (DATE) 'sC ""......~ CITY OF PORT ANGELES PUBLIC WORKS - ELECTRICAL DIVISION '21 EAST 5TH STREET. PORT ANOELES. WA 98.,(,2 ELECTRICAL PERMIT ISSUED: 1 1 PERMIT NO 7387 OWNER/APPLICANT City of Port Angeles 321 E. 5th Street Port Angeles, WA 98362 360/417-4815 T: S: ARCHITECT NIA CONTRACTOR ANGELES ELECTRIC 524 E. 1ST ST. PORT ANGELES, WA 98362-0000 360/452-9264 PROPERTY LOCATION 400 FRANCIS N Lot: 8-10 Block: 32 D Long Legal Subdivision: N.R.Smith Parcel No: 063000513235000 , 98360-0000 360/000-0000 Project Value: $0.00 Construction Type: SERVICE INSTALL Zoning Use: PROJECT INFO Project Type: Occupancy Type: Occupancy Group: Electrical Heat: D Baseboard D Furnace D Heat Pump D Fan Wall CITY PROPERTY o KW o KW o KW o KW D Riser [:2J D Overhead Service D Temp Service Underground Service Voltage: 120,240 Phase: [:><J 1 D 3 Service Size: 60 Feeder Size: 0 -I: (:1 o z . .." "'I Sl> :S ~ PROJECT NOTES 60 amp service for park lighting ~. ("A FEES ASSESSMENT Service: Additionai Feeders: Circuit Wiring: Temp Service: Misc Fee: TOTAL FEE: AMOUNT PAID: BALANCE DUE CmhY1J:l'TSI ACTION NEEDED $74.30 $0.00 $0.00 $0.00 $0.00 $74.30 $74.30 $0.00 ELECTRICAL PERMIT INSPECTION RECORD CALL 417-4735 FOR ELECTRICAL INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLA WFUL TO COVER, INSULA TE OR CONCEAL ANI' WORK BEFORE IT IS INSPECTED AND ACCEPTED. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE 7 '7 c;7 INSPECTION TYPE DATE I ACCEPTED COMMENTS I YES I NO KllllliH-lN II..-UV.tlK ~~ <th%f ''''J~ I "i//O/A. I J/.J-. I GENERAL COMMENTS: PW.II02.1S(4I96] .. .