Loading...
HomeMy WebLinkAbout536 W 8th St - Building :f90r...~ 8~o~~~ ha "-- -=..or ~ "l,\~ CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY DEVELOPMENT - BUILDING DIVISION 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Application Number pin number Property Address ASSESSOR PARCEL NUMBER: Applicatlon descriptlon Subdivision Name Property Use Property Zoning . . . Appllcation valuatlon 04-00000948 .579760 536 W 8TH ST 06-30-00-0-2-6334-0000- RES ADDITION Date 10/28/04 Owner Contractor \==n,JA LED - '11'Z~jo1\jL L/ COMMERCIAL NEIGHBORHOOD 20000 ENGLISH, MONTE/LESLIE 255432 HWY 101 EAST PORT ANGELES (360) 452-2500 Structure Information Construction Type Occupancy Type Other struct info OWNER WA 98362 281 SF ADDITION TYPE V NON-RATED SINGLE FAM & CONGREGATES TOTAL % LOT COVERAGE CONSTRUCTION TYPE HARD SURFACE AREA NUMBER OF STORIES EXISTING LOT COVERAGE LOT SIZE PROPOSED LOT COVERAGE TOTAL LOT COVERAGE NUMBER OF UNITS 27.60 V-N 2.00 1657.00 7000.00 281. 00 1938.00 1. 00 :vlo.-Vv~ ~ 6\ \ ,\ ~ \)/ \9 -+ 5 Permit BUILDING PERMIT -RESIDENTIAL Addltional desc Permit Fee 344.75 Plan Check Fee 13 7.90 Issue Date 10/28/04 Valuatlon 20000 Explration Date 4/27/05 Qty Unit Charge Per Extension BASE FEE 92.75 18.00 14.0000 THOU BL-2001-25K (14 PER K) 252.00 Permit MECHANICAL PERMIT Addltional desc Permit Fee 76.00 Plan Check Fee .00 Issue Date 10/28/04 Valuation 0 Expiration Date 4/27/05 Qty Unit Charge Per Extension BASE FEE 47.00 4.00 7.2500 ECH ME-VENT FAN 29.00 Permit PLUMBING PERMIT Additional desc Permit Fee 89.00 Plan Check Fee .00 Issue Date 10/28/04 Valuation 0 Explration Date 4/27/05 Qty Unlt Charge Per Extension BASE FEE 47.00 6.00 7.0000 ECH PL- EA.FIXTURE ON ONE TRAP 42.00 Speclal Notes and Comments Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utIlities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last inspection I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing thiS type of work Will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Signature of Contractor or Authorized Agent Date Date T.\PLANNING\FORMSIlI02 15 [11/14/2003] CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY DEVELOPMENT - BUILDING DIVISION 321 EAST 5TH STREET, PORT ANGELES, W A 98362 Appllcation Number . . . .. 04-00000948 pin number . . .579760 Page 2 Date 10/28/04 Special Notes and Comments wells or piped to approved storm drain locations. The proposal will result in a 281 s.f. addition and foundatlon/roof repair to a s.f. residence for total lot coverage of 28% . Setbacks are good. No land use lssues are noted. Other Fees STATE SURCHARGE 4.50 Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Perml t Fee Total 509.75 509.75 .00 .00 Plan Check Total 137.90 137.90 .00 .00 Other Fee Total 4.50 4.50 .00 .00 Grand Total 652.15 652.15 .00 .00 Xl I Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Signature of Contractor or Authorized Agent Date Signature of Owner (if owner is builder) Date T.\PLANNING\FORMS\1102.15 [11/14/2003] BUILDING PERMIT INSPECTION RECORD ". " CALL 417-4815 FOR BUILDING INSPECTIONS. CALL 417-4735 FOR ELECTRICAL INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLA WFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE. INSPECTION TYPE DATE ACCEPTED COMMENTS YES I NO FOUNDATION: FOOTINGS , , ~-t9';- .J. J.... - WALLS - {q-ro-r J. L. FOUNDATION DRAINAGEIDOWN SPOUTS ELECTRICAL (LIGHT DEPT) SEPARATE PERMIT. # ROUGH-IN I I PLUMBING HN 4--L ,/U/O~ Jt-L- UNDER FLOOR 1 SLAB ROUGH-IN ~ - ~<j(-06' odJ.1- WATER LINE (METER TO BLDG) GAS LINE BACK FLOW 1 WATER AIR SEAL WALLS ~)J-~.~ 1...1 J-L CEILING I FRAMING JOISTS 1 GIRDERS SHEAR W ALL/HOLD DOWNS u- !).t- OS- ~J-~ WALLS 1 ROOF 1 CEILING ~ )'I_ti'l .~ J }..L DRYW ALL (INTERlOR BRACED PANEL ONLY) T-BAR INSULATION SLAB WALL 1 FLOOR 1 CEILING 1(' -..<;'" - OS .j L l I MECHANICAL h"'lJ-t- '7/2-2/0<) S"LL HEAT PUMP GAS LINE WOOD STOVE 1 PELLET 1 CillMNEY HOOD 1 DUCTS PW UTILITIES 1 SITE WORK (Engmeenng DIVISIon) SEPARATE PERMIT #'s WATERLINE 1 METER SEWER CONNECTION SANITARY STORM PLANNING DEPT SEPARATE PERMIT #'s SEPA: PARKINGILIGHTlNG ESA: LANDSCAPING SHORELINE FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/uSE RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED YES NO ELECTRlCAL - LIGHT DEPT. 417-4735 ELECTRlCAL LIGHT DEPT CONSTRUCTION R. W. 1 PWI 1 ~1.2.. CONSTRUCTION - R.W. ENGINEERING 417-4807 PW 1 ENGINEERING FIRE 417-4653 FIRE DEPT. PLANNING DEPT. 417-4750 I PLANNING DEPT. BUILDING 417-4815 71U1()~ ,aLl- BUILDING T.\PLANNING\FORMS\110215 11/14/2003 , ENGLISH, MONTE/LESLIE 06-30-00-0-2-6334-0000- 04-00000948 RES ADDITION PREPARED 7/22/05, 12 08 06 CITY OF PORT ANGELES ADDRESS CONTRACTOR OWNER PARCEL APPL NUMBER 536 W 8TH ST INSPECTION TICKET INSPECTOR JAMES L LIERLY PAGE DATE 2 7/22/05 SUBDIV PHONE PHONE (360) 452-2500 PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL1 01 1/11/05 JLL 1/11/05 DA BL1 02 1/12/05 JLL 1/12/05 AP BI2 01 1/19/05 JLL 1/20/05 AP BL3 01 3/11/05 JLL 3/11/05 DA BL9 01 4/21/05 JLL 4/22/05 AP BAIR 01 5/04/05 JLL 5/04/05 AP BL3 02 5/04/05 JLL 5/04/05 AP BLI 01 5/05/05 JLL 5/05/05 AP BL99 01 ~~~ BUILDING FOUNDATION FOOTING MONTY 477-9657 tle vert bar to horlzontal 10 footlng at 4'-011 mln 0 C BUILDING FOUNDATION FOOTING STEVE HEUN 477-9657 BUILDING FOUNDATION WALL TIME: 17 00 MONTE 477-9657 BUILDING FRAMING MONTE 477-9657 MORNING INSPECTION deck screws not allowed ln framlng structural members/Jll BUILDING SHEARWALL Monte 477-9657 04/21/2005 11:01 AM RVESS 04/22/2005 08 21 AM JLIERLY ---------------------------- BUILDING AIR SEAL MONTE 477-9657 05/04/2005 11 46 AM JLIERLY 05/04/2005 04 15 PM JLIERLY ---------------------------- BUILDING FRAMING TIME. 17:00 MONTE 477-9657 05/04/2005 11:48 AM JLIERLY 05/04/2005 04 15 PM JLIERLY ---------------------------- BUILDING INSULATION MONTE 477-9657 05/05/2005 11 23 AM JLIERLY 05/05/2005 04 38 PM JLIERLY ---------------------------- BUILDING FINAL 07/21/2005 04 01 PM JLIERLY MONTEY 477-9657 COMMENTS AND NOTES PREPARED 7/22/05, 16 32.03 CITY OF PORT ANGELES 536 W 8TH ST 'INSPECTION TICKET INSPECTOR JAMES L LIERLY ADDRESS CONTRACTOR OWNER PARCEL APPL NUMBER ENGLISH, MONTE/LESLIE 06-30-00-0-2-6334-0000- 04-00000948 RES ADDITION PERMIT: ME 00 MECHANICAL PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 7/22/05 -ift-J ~+=r ----------------------------------- CONTINUED ONTO ME99 01 MECHANICAL FINAL 07/22/2005 04 30 PM JLIERLY ---------------------------- SUBDIV PHONE PHONE (360) 452-2500 PAGE DATE 3 7/22/05 NEXT PAGE ----------------------------------- ADDRESS CONTRACTOR OWNER PARCEL APPL NUMBER 536 W 8TH ST PREPARED 7/22/05, 16 32 03 CITY OF PORT ANGELES ENGLISH, MONTE/LESLIE 06-30-00-0-2-6334-0000- 04-00000948 RES ADDITION -INSPECTION TICKET INSPECTOR JAMES L LIERLY PAGE DATE 4 7/22/05 SUBDIV PHONE PHONE (360) 452-2500 PERMIT: PL 00 PLUMBING PERMIT REQUESTED INSP TYP/SQ COMPLETED RESULT PL2 01 3/28/05 3/28/05 5/04/05 5/04/05 PL2 02 PL99 01 7/22/.05 ~ JLL AP JLL CA JLL prp DESCRIPTION RESULTS/COMMENTS PLUMBING ROUGH-IN TIME. 17 00 Brlan 457-8249 PLUMBING ROUGH-IN TIME 17.00 MONTE 477-9657 05/04/2005 11 47 AM JLIERLY 05/04/2005 04 16 PM JLIERLY ---------------------------- thlS lnspectlon was approved prevlously/]ll PLUMBING FINAL TIME 17:00 07/22/2005 04 30 PM JLIERLY ---------------------------- -------------------------------------- COMMENTS AND NOTES -------------------------------------- PREPARED 5/05/05, 13 07 55 CITY OF PORT ANGELES ADDRESS CONTRACTOR OWNER PARCEL APPL NUMBER 536 W 8TH ST INSPECTION TICKET INSPECTOR JAMES L LIERLY PAGE DATE 1 5/05/05 ENGLISH, MONTE/LESLIE 06-30-00-0-2-6334-0000- 04-00000948 RES ADDITION SUBDIV PHONE PHONE. (360) 452-2500 PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL1 01 1/11/05 JLL 1/11/05 DA BL1 02 1/12/05 JLL 1/12/05 AP BI2 01 1/19/05 JLL 1/20/05 AP BL3 01 3/11/05 JLL 3/11/05 DA BL9 01 4/21/05 JLL 4/22/05 AP BAIR 01 5/04/05 JLL 5/04/05 AP BL3 02 5/04/05 JLL 5/04/05 AP BUILDING FOUNDATION FOOTING MONTY 477-9657 t1e vert bar to horlzontal 10 footlng at 4'-0" ffiln C.C BUILDING FOUNDATION FOOTING STEVE HEUN 477-9657 BUILDING FOUNDATION WALL TIME 17 00 MONTE 477-9657 BUILDING FRAMING MONTE 477-9657 MORNING INSPECTION deck screws not allowed ln framlng structural members/)ll BUILDING SHEARWALL Monte 477-9657 04/21/2005 11 01 AM RVESS 04/22/2005 08 21 AM JLIERLY ---------------------------- BUILDING AIR SEAL MONTE 477-9657 05/04/2005 11.46 AM JLIERLY 05/04/2005 04.15 PM JLIERLY ---------------------------- BUILDING FRAMING TIME' 17.00 MONTE 477-9657 05/04/2005 11:48 AM JLIERLY 05/04/2005 04 15 PM JLIERLY ---------------------------- ~~:__::__~~~_____~~~~~:N:::~::::T:::/::~::o:--~~-::--~__~~:~~~~_________________ PREPARED 5/04/05, 13 10.44 CITY OF PORT ANGELES ADDRESS CONTRACTOR OWNER PARCEL APPL NUMBER 536 W 8TH ST INSPECTION TICKET INSPECTOR: JAMES L LIERLY PAGE DATE 3 5/04/05 ENGLISH, MONTE/LESLIE 06-30-00-0-2-6334-0000- 04-00000948 RES ADDITION SUBDIV' PHONE PHONE (360) 452-2500 PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BUILDING FOUNDATION FOOTING MONTY 477 - 9657 tl€ vert bar to horlzontal In fOOtlTIg at 4'-011 ffiln 0 c. BUILDING FOUNDATION FOOTING STEVE HEUN 477-9657 BUILDING FOUNDATION WALL MONTE 477-9657 BUILDING FRAMING MONTE 477-9657 MORNING INSPECTION deck screws not allowed ln framlng structural members/)ll BUILDING SHEARWALL Monte 477-9657 04/21/2005 11 01 AM RVESS 04/22/2005 08:21 AM JLIERLY ---------------------------- BAIR 01 4/0tOs.,...../~L BUILDING AIR SEAL ~ d ~ MONTE 477-9657 05/04/2005 BL3 02 / /05 /*LL BUILDING FRAMING TIME 17 ~~ _ MONTE 477-9657 05/04/2005 -------------------------- ----- -- CONTINUED ONTO NEXT PAGE ----------------------------------- BL1 01 1/11/05 1/11/05 JLL DA BL1 1/12/05 1/12/05 1/19/05 1/20/05 3/11/05 3/11/05 JLL AP JLL AP JLL DA 02 BI2 01 BL3 01 BL9 4/21/05 4/22/05 JLL AP 01 TIME: 17'00 11 46 00 11-48 AM JLIERLY AM JLIERLY PREPARED 5/04/05, 13 10 44 CITY OF PORT ANGELES ADDRESS CONTRACTOR OWNER PARCEL . . APPL NUMBER 536 W 8TH ST ENGLISH, MONTE/LESLIE 06-30-00-0-2-6334-0000- 04-00000948 RES ADDITION INSPECTION TICKET INSPECTOR JAMES L LIERLY SUBDIV' PHONE PHONE (360) 452-2500 PAGE DATE 4 5/04/05 PERMIT: PL 00 PLUMBING PERMIT REQUESTED INSP DESCRIPTION ;;;I';;---':;::;:;"-~'--::~:;f':~';';~--;;;;--;;-;;--------------------------------- 3/28/05 AP Br1an 457-8249 PL2 02 ~~~(~~ PLUMBING ROUGH-IN TIME 17 00 ~ ~ MONTE 477-9657 05/04/2005 11:47 AM JLIERLY -------------------------------------- COMMENTS AND NOTES -------------------------------------- PREPARED 4/21/05, 13'20.01 CITY OF PORT ANGELES INSPECTION TICKET INSPECTOR' JAMES L LIERLY PAGE DATE 2 4/21/05 ADDRESS CONTRACTOR OWNER PARCEL APPL NUMBER: 536 W 8TH ST SUBDIV PHONE PHONE (360) 452-2500 ENGLISH, MONTE/LESLIE 06-30-00-0-2-6334-0000- 04-00000948 RES ADDITION PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL1 01 1/11/05 1/11/05 JLL DA BUILDING FOUNDATION FOOTING MONTY 477-9657 tle vert bar to horlzontal lD footlng at 4'-0" ffilD 0 c. BUILDING FOUNDATION FOOTING STEVE HEUN 477-9657 BUILDING FOUNDATION WALL MONTE 477-9657 BUILDING FRAMING MONTE 477-9657 MORNING INSPECTION deck screws not allowed 1n fram1ng structural members/]ll ~::__:~__~~~___~:~:::N:O::::::~::D ::~::/::::__~~_:~__~__:~:::________________ 02 1/12/05 1/12/05 1/19/05 1/20/05 3/11/05 3/11/05 JLL AP JLL AP JLL DA TIME 17:00 BL1 BI2 01 BL3 01 PREPARED 3/28/05, 13 03 07 CITY OF PORT ANGELES INSPECTION TICKET INSPECTOR JAMES L LIERLY PAGE DATE 2 3/28/05 ADDRESS CONTRACTOR OWNER PARCEL APPL NUMBER 536 W 8TH ST SUBDIV PHONE PHONE' (360) 452-2500 ENGLISH, MONTE/LESLIE 06-30-00-0-2-6334-0000- 04-00000948 RES ADDITION PERMIT: PL 00 PLUMBING PERMIT REQUESTED INSP TYP/SQ COMPLETED RESULT DESCRIPTION RESULTS/COMMENTS PL2 01 ';1~2~~('" it~ PLUMBING ROUGH-IN ~ f- Brlan 457-8249 -------------------------------------- COMMENTS AND NOTES -------------------------------------- TIME 17 00 PREPARED 3/11/05, 13 07 42 CITY OF PORT ANGELES INSPECTION TICKET- INSPECTOR JAMES L LIERLY PAGE DATE ADDRESS CONTRACTOR OWNER PARCEL APPL NUMBER 536 W 8TH ST SUBDIV. PHONE PHONE. (360) 452-2500 ENGLISH, MONTE/LESLIE 06-30-00-0-2-6334-0000- 04-00000948 RES ADDITION PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL1 01 1/11/05 JLL 1/11/05 DA BL1 02 1/12/05 JLL 1/12/05 AP BI2 01 1/19/05 JLL 1/20/05 AP BL3 01 ~$~ BUILDING FOUNDATION FOOTING MONTY 477-9657 tle vert bar to horlzontal In footlng at 4'-0" ffiln 0 C. BUILDING FOUNDATION FOOTING STEVE HEUN 477-9657 BUILDING FOUNDATION WALL TIME 17 00 MONTE 477-9657 BUILDING FRAMING MONTE 477-9657 MORNING INSPECTION 2 3/11/05 -------------------------------------- COMMENTS AND NOTES -------------------------------------_ ~c:~::, 1l~ J.b~ ~\I00eO I~ & -t i2iJ cA-urt-'-O-1 t ~-,e Lf1IJ; (:}OU.~)\Nc11-cnJ ~ PREPARED 1/19/05, 12.05'50 CITY OF PORT ANGELES ADDRESS CONTRACTOR OWNER PARCEL . APPL NUMBER, 536 W 8TH ST INSPECTION TICKET INSPECTOR JAMES L LIERLY PAGE DATE ENGLISH, MONTE/LESLIE 06-30-00-0-2-6334-0000- 04-00000948 RES ADDITION SUBDIV PHONE PHONE, (360) 452-2500 PERMIT, BPR 00 BUILDING PERMIT - RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL1 01 1/11/05 JLL 1/11/05 DA BL1 02 1/12/05 JLL 1/12/05 AP BI2 01 ~ JLL ~ BUILDING FOUNDATION FOOTING MONTY 477-9657 tle vert bar to horlzontal lD footlng at 4'-0" ffilTI 0 C BUILDING FOUNDATION FOOTING STEVE HEUN 477-9657 BUILDING FOUNDATION WALL TIME, 17.00 MONTE 477-9657 8 1/19/05 -------------------------------------- COMMENTS AND NOTES -------------------------------------- BUILDING PERMIT - APPLICATION Date Issued Fill out COMPLETELY and in INK. Your application and site plan MUST B COMPLETE to be accepted for review. If you have any questions, call PERMITS (360) 417-4815 FAX(360)417-4711 ApplIcant or Agent: fJlO)J rer eN G- ~ /<.1' If Phone: Owner: ,--r~ke- Phone: Address: c2SS $/..f~ 1f1Vy' /0/ CIty: ff AN 6eC.e::.r , ArchItect/Engmeer: C H.4~ U ~ (SA-( I rH- Phone: Contractor OWN ~~ State LIcense #: Exp: 9:J 2 - "2.J"C c Zip: Y<:f7?6 Z- ~.2.'6 /16 Phone: City: tv es-r e-d Block: ./6.3 SubdIVISIOn: 06:JOOO - 02.6.:J3~ ZIp: ZONING: 'TO~/Ju/j"€" t>~ Address: PROJECT ADDRESS: S..? b LEGAL DESCRIPTION: Lot: 9 CLALLAM COUNTY PARCEL NUMBER: f!A. Credit Card Holder Name: Billing Address: Credit Card Type VISA MC # TYPE OF WORK: lSY"ResIdentlal D New Constr. rie-roof D Stove D Multi-farmly lit'" Additlon D Move D Garage D CommercIal cY'Remodel D DemohtiOn D Deck D Reparr D Sign D Other BRIEF DESCRIPTION OF THE PROJECT. be- 11 0 /oJ ~.(JJ flifJ> /t..oo~. OA'tk,foiJI"f ,Hila""""" - . City: Exp. Date: SIZEN ALUATlON: ~8( SF.@$ /SF =$ to, DoC SF. @ $ /SF. = $ SF.@$ /SF.=$ TOTAL VALUATION $ E'/CIST/#J(; I;i( ru.lT'f A/)o~ o"o:.j) RfFRoor -r P~(,tJ po~,.,JjMI()~ COMMERCIAL/RESIDENTlAL: Occupancy Group: No. of Stones: -L Lot SiZe: ? t!XX> I Existlng Sq. Ft 11057 Total lot coverage_ 2.7 J f:; % Occupant Load: Construction Type: & Proposed Sq. Ft. l 81 = TOTAL Sq. Ft. 1'7.? 8 APPROVALS: PLAN: BLDG: DPWU: FIRE: OTHER:_ PLANNING USE ONLY: ESAlWetland(s): DYes D No SEPA Checkhstrequrred? DYes D No Other: BUILDING PERMIT APPLICATION SUBMITTAL: The BUlldrng DiViSiOn can provIde you With informatiOn on the applIcation and plan submittal requrrements If you have questions. VALUATION OF CONSTRUCTION. In all cases, a valuation amount must be entered by the apphcant. This figure will be revIewed and may be revised by fue BUlldrng DIVISiOn to comply With current fee schedules. Contact the Perrmt Coordrnator at 417 -4815 for aSSIstance. PLAN CHECK FEE IF a plan check fee IS due It must be submitted at the time the bUlldrng perrmt applicatiOn and constructIOn plans are subrmtted. All other perrmt fees are due at the trme of perrmt Issuance EXPIRATION OF PLAN REVIEW: Uno perrmt IS Issued wIthrn 180 days of the date of application, the application will expire. The BUlldrng OffiCial can extend the time for actiOn by the applicant up to 180 days upon wntten request by the applIcant (see Section R 105.3 2 of the InternatiOnal BUlldrng/ResIdentlal Code, 2003). No applIcation can be extended more than once. I hereby certify that I have read and examined thiS application and know the same to be true and correct. I am authonzed to apply for thIS permit and understand that it is my responsibility to determme what permils are reqUired ,not the City's, and that I must obtain such permits pnor to work. ?tPiZl{~ Date: /" -S- r Apphcant: T \RVESS\BLDG-forms-brochures\2003-BUlldmgpermlt wpd CRETE REMAIN ,TING :> PROviDE I AS SHOUN o I r- N .. ~ '~ ~' ~J I .. (p <.\l 8TH STREET \ 3~~.:.1~._.. ~.'~.'~::_.._.._.t..:...:'n~.._t ~ N N b I ~I = J (), I I I I I I .e,....1 Nv~.J ~ --- I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I ~ : ~~ I --------~---------------" '" " =- \/ ~~~~~ ,~~.....; '\" ,\:~~""'::...~ ~: ~~ ~~ EXplTING ~': c,' 5 T ?RAGE ~~ : ~~,;',':::h,; ..."" ,"" ~ : ~~ ; ," I ~ I ~ : " ' ~~: "~ ,~ ..." ;;: EX5l1'INfr-----:~ ~~ GARAC:lE ~, ~~ ,~ ~ ~s:: ~~-.::.::,> '::-~'-':' ~~~"'-:-.::'';~ ~~,,%~~~~ , ,,' ,~ ) -, ___60_.'_'._.._.._0._'._.._"_.._.'_0._.'_,,_,.___ . . I L-Pbl .1>4:-1'- REFAIR EXI5TINC:I DEe AND FOUDATION FRO NEW 5TEF5 AND RAIL , , i rr', ~~ "1,,1,1 -j - >1 ; , tlf I 'J;;II Ii "11 '11,-: ,;Ii:: J ' ~ I > ' ~I ~ 'j! of , -,illl] , -' ,1,,( " )j21~;1' >~II~~! ',,!.^H . :;F;~ PREPARED 1/12/05, 12 27 16 CITY OF PORT ANGELES INSPECTION TICKET INSPECTOR JAMES L LIERLY PAGE DATE 3 1/12/05 ADDRESS CONTRACTOR OWNER PARCEL . APPL NUMBER 536 W 8TH ST SUBDIV. PHONE PHONE (360) 452-2500 ENGLISH, MONTE/LESLIE 06-30-00-0-2-6334-0000- 04-00000948 RES ADDITION PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BLl 01 1/11/05 1/11/05 JLL DA BUILDING FOUNDATION FOOTING MONTY 477-9657 tIe vert bar to horIzontal In footIng at 41-0" mIn 0 C BLl 02 \/rl~r:(~~L BUILDING FOUNDATION FOOTING ~ STEVE HEUN 477-9657 ------------------------- ------------ COMMENTS AND NOTES ---------------------------------_____ PREPARED 1/11/05, 12 26 22 CITY OF PORT ANGELES INSPECTION TICKET INSPECTOR JAMES L LIERLY PAGE DATE 4 1/11/05 536 W 8TH ST ------------------------------------------------------------------------------------------------ ADDRESS CONTRACTOR OWNER PARCEL APPL NUMBER ENGLISH, MONTE/LESLIE 06-30-00-0-2-6334-0000- 04-00000948 RES ADDITION SUBDIV PHONE PHONE (360) 452-2500 --------------~--------------------------------------------------------------------------------- PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL1 ~&- ------------------------------------------------------------------------------------------------ BUILDING FOUNDATION FOOTING MONTY 477-9657 01 -------------------------------------- COMMENTS AND NOTES ------------------------------------__ TIl~ Y\.\~ V~i2-+ ~~(L t l ( 4 -0 0 ( h, UC/\.l ~u Foo+,:S A ~(df'- Olympic Peninsula Home Inspection Inc.. Report \ Page 1 of 8 '\ --:-~%P Home Olympic Inspection, l1=n;nsu/a Inc. Steven Dailey, Inspector 161 Stone Rd., Sequim, WA 98382 Phone: 360.681-6908 · Fax: 360-681 -6008 E-mail.stevedaJley@ho1mail.com License # 602396974 Website: httQ..Jlwww.reporthost.corr Email: ~tevedailey..@lJQ.tma Phone: (360) 681-6908 161 Stone Rd. Sequim Wa. 98382 Inspector: Steven Daile\ Home Inspection Client{s): Mike Libera Property address: 536 West 8th Street, Port Angeles, Wa 98362 Inspection date: 07/24/2004 This report published on 7/24/2004 5:39:57 PM PDT View summary ~~ Your default report header here... How to Read this Report This report is organized by the property's functional areas. Within each functional area, descriptive information is listed first and shown in bold type. Items of concern follow descriptive information and are shown as follows: + Safety Poses a risk of Injury or death I!Ial Major defect Correction likely involves a significant expense ~ Repair/Replace Recommend repairing or replacing , Repair/Maintain Recommend repair and/or maintenance ~ Minor defect Correction likely Involves only a minor expense ~ Maintain Recommend ongoing maintenance ~ Evaluate Recommend evaluation by a specialist M Monitor Recommend monitoring In the future 0 Comment For your information -- Concern items are sorted by the types listed above. Click here for a glossary of building construction terms. Structural Pest Inspection Concerns Items marked with the follOWing icons relate to the structura pest inspection ~ Infestation Evidence of infestation of wood destroying insects or organisms (Live or dead insect bodies, fungal growth, etc.) Olympic Peninsula Home Inspection Inc.. Report Page 2 of8 ~ Damage Damage caused by wood destrOYing insects or organisms (Rot, carpenter ant gallenes, JJ:. etc.) & Conducive Conducive conditions for wood destrOYing Insects or organrsms. (Wood-soil contact, conditions shrubs in contact with siding, roof or plumbing leaks, etc.) General information Overview: The overall structure appears to need serious repair and maintanance to include floor Joist and support beams. Overview: Overall structure in serious repair and maintenance. Structures inspected: 1 family dwelling and detached Garage Structures inspected: 1 Family Dwelling and Detached Garage Seller's name: Shirley Wooldridge Report number: LIBERA-07242004 Time started: 12:00 Noon Time finished: 2:45pm Inspection Fee: 325.00 Present during inspection: Other/Cindy Lebera Occupied: No Age of building: Approximate 100 years Type of building: Single family Weather conditions: Clear Temperature: Hot Ground condition: Dry Main entrance faces: North Foundation type: Post and pier The following items are excluded from this inspection: Private sewage disposal system, Security system, Irrigation system, Swimming pool, Hot tub, Private well, Shed, Playground equipment, Sauna, Low voltage outdoor lighting, Central vacuum system, Water filtration system, Water softener system, Built-in sound system, Intercom system, Generator system, Sport court ._.~- ~._-~ .._~- -- ~--~----_._--- ---------_._------------~-------_.- Exterior Footing material: NONE Foundation material: Post and pier Apparent wall structure: Wood frame Wall covering: Wood shingles Driveway material: NONE Sidewalk material: Poured in place concrete Exterior door material: Solid core wood Water pressure (psi): UNKNOWN ~ i:r~ 1) Soil IS in contact with or less than 6" from siding and/or tnm. Wood siding and/or A~ trim IS rotten in some areas because of this. Recommend grading soil so there's at least 6" of space between the siding and trim and the soil below. Recommend replacing all rotten trim and siding materials. ~ ~ 2) One or more downspouts are mIssing. Recommend having a qualified gutter and downspout contractor install downspout(s) where miSSing. Also recommend installing extensions such as splashblocks or a drain line where necessary to carry rainwater away from the house. ~ G) 3) One or more downspouts are loose or detached. Recommend repairing these downspouts where necessary. ~ ~ 4) One or more downspout extensions are miSSIng and/or IneffectIve. Recommend , ,. " IT T~""""T"lo , ,...,...,_ ..._n.^.. I qlympic Peninsula Home Inspection Inc.. Report l"age .:; or lS installing extensions such as splash blocks or a drain line where missing, or repairing where necessary so rain water IS carried at least several feet away from the structure to soil that slopes down and away from the structure. ~ ~ 5) One or more gutters are missing. Recommend having a qualified gutter and downspout contractor install gutters, downspouts where missing. Also recommend Installing extensions such as splashbloc_k!? PI ~ draJIJ_lilJe.wt:Le~e necessary to carry rain water away from the house. On both the West and East side. ~ & 6) Some areas of the structure need repainting due to peeling, cracking and/or blistenng of paint. Recommend having a qualified painting contractor evaluate, prep (scrape, sand, prime and caulk) properly and repaint where necessary. " ~ 7) Vegetation (trees, shrubs and/or vines) are in contact with building exterior. Recommend pruning or removing vegetation as necessary so there's at least a one foot gap between all vegetation and the building exterior. This gap should exist to allow exterior building materials to dry quickly after it rains, and to eliminate pathways to the structure for wood destroying insects. " ~ 8) The finish on the deck is worn and/or deteriorated. Recommend cleaning and repainting deck. " ~ 9) Caulk is missing or deteriorated in some areas. Recommend caulking where necessary. " 10) Soil is In contact with or less than 6" from siding and/or trim. Recommend grading soil so there's at least 6" of space between the siding and trim and the soil below. " 11) Dryer vent cap is damaged. Recommend replacing. H 12) One or more large trees are very close the dwelling Recommend removing such trees to prevent damage to the dwelling. Detached garage or carport Footing material: Not visible Foundation material: None Apparent wall structure: Wood frame Wall covering: Wood clapboard, Wood shakes Exterior door material: Solid core wood, Wood panel Roof inspection method: Viewed from ground Roof type: Gable Roof covering: Asphalt or fiberglass composition shingles Estimated age of roof: Unkown Gutter & downspout material: None Roof ventilation: None visible +~ 13) Wire connections exposed due to missing cover plate(s) over one or more outlet boxes. Recommend installing cover plates over boxes where mlsslng.On West side has entering garage. ~~ G) 14) Entire structure needs repainting. Recommend haVing a qualified painting contractor evaluate, prep (scrape, sand, prime and caulk) properly and repainting entire bUilding. rn~ 15) The garage doors need to be replaced. ~ mr'& 16) Soil is In contact with or less than 6" from siding and/or trim. Wood siding and/or .&,' trim is rotten in some areas because of this. Recommend grading soil so there's at least 6" of space between the siding and trim and the soil below. Recommend replacing all rotten trim and siding materials. ~ & 17) One or more gutters are missing. Recommend having a qualified gutter and downspout contractor install gutters, downspouts where missing. Also recommend ht+....//nrnrnr TA...nrthnct f>nm/nh,npnfT lRPR A ()7?4 ?()()4/ 7/27/2004 Olympic Peninsula Home Inspection Inc.. Report Page 4 of8 installing extensions such as splash blocks or a drain line where necessary to carry rain water away from the house. ,. 18) Soil is in contact With or less than 6" from siding and/or trim. Recommend grading soil so there's at least 6" of space between the siding and trim and the soil below. " , 19) Moss is growing on the roof. This can lead to the premature failure of the roof and subsequent leaks. Recommend treating moss during its growing season (wet months) with a moss killer. For information on various moss treatment products and their pros and cons, Visit httR..JjbrY~Rtr~te_s-,-glence_.o@.gonstate.eduLQage24.htm Recomend having a roofing contractor inspect the foor-needs replaced. ~ 20) Weatherstnp around one or more exterior doors is damaged, deteriorated. Recommend replacing weatherstripping at exterior door(s) where necessary. Roof Roof inspection method: Viewed from ground Roof type: Gable Roof covering: Asphalt or fiberglass composition shingles Estimated age of roof: Unknown Gutter & downspout material: None Roof ventilation: Adeauate +~ 21) Screened cover(s) missing from chimney(s). Recommend having a qualified chimney service contractor install screened cover(s) where missing to prevent rain water from entering chimney(s) and to prevent sparks from spreading dunng a fire. The screen should have holes 1/4" or larger. ~~ 22) The roof should be inspected by a roofing contractor -replacement. 0 ~O 23) ThiS asphalt or fiberglass composition roof has two or more layers of roofing materials. When thiS roof IS replaced, recommend a complete "tear off", where all existing layers of roofing are removed before installing new roofing materials. With each layer of material added to a roof, the new roof material's lifespan is reduced as follows: . 16-20 years - First roof . 12-16 years - Second layer on existing roof Removing eXisting roofing materials will significantly increase the cost of the next roof. ~~ 6) 24) The chimney is wider than 2' and no "cricket" (a small ridged roof section just M above the chimney to shed water off to the sides) IS installed above the chimney. Organic debris from trees may accumulate here and cause leaks. Recommend monitonng this area for accumulated debris and cleaning when necessary. Recommend installing a cricket when next roof is installed. ~~ 25) Masonry chimney mortar is detenorated. Recommend haVing a qualified chimney service contractor or mason evaluate chimney and repair as necessary. This will likely require repointing the mortar. ~M 26) Chimney crown needs repairs. Recommend haVing crown evaluated by a qualified 0 chimney service contractor or mason and repaired or replaced as necessary. For information on the correct way to build a chimney crown visit: httR-:lLwww. askbulld. comLc9l=..QLnL colum n ?092 " ~ 27) Moss is growing on the roof. This can lead to the premature failure of the roof and subsequent leaks. Recommend treating moss during its growing season (wet months) with a moss killer. For information on various moss treatment products and their pros and cons, visit httQ :LLbryoQhytes.sClence.oregonstate.edu/Rage24.htm 1 ~.j I' .1 I 1 IT my,y-" .a. ^_^ """"''''''' A I qlympic Peninsula Home Inspection Inc.. Report J:'age :) 01 lS Electric service Primary service type: Overhead Primary service overload protection type: Fuses Service amperage (amps): 100 Service voltage (volts): 120-240 Location of main service panel: EAST WALL OF BACK PORCH Location of sub panels: EAST WALL OF BACK PORCH Service conductor material: UNKNOWN Main disconnect rating (amps): Not applicable, no single main disconnect Branch circuit wiring type: Non-metallic sheathed Solid strand aluminum branch circuit wiring present: No k d N Smo e etectors present: 0 +~ 28) An insuffIcient number of smoke detectors are inst~lIed. Recommend installing additional smoke detectors as necessary so a functioning one exists in each hallway leading to bedrooms, and in each bedroom. For more inf~rmation on smoke detectors visit httQ..;iLwww. cgscgQYLc.gsq::)ub/gubsL5Q77. html '? < " ~~ 29) Legend for overcurrent protection devices (breakers or fuses) in the main service panel is missing, unreadable or incomplete. Recommend installing, updating or correcting the legend as necessary so it's accurate. Water heater Estimated age: APROXIMATE 21 YEARS Type: Tank Energy source: Electricity Capacity (in gaUons): 52 Brand 8L model: RELIANCE Water temperature (degrees Fahrenheit): 120 +~ 30) Hot water heater improperly supported, missing earthquake straps. Recommend installing earthquake straps. 1:DIll~ 31) The estimated useful life for water heaters is 8 to 12 years. This water heater appears to be approaching this age. Recommend budgeting for a replacement in the near future. __ ~__ _~____"___ ~n.__ _~__~ . ~"_ 'M_____P_._"~_._ ---> ~___"____~_____~ - ~------------_._---~------------..----- Heating and air conditioning Heating system energy source: Oil Heat system type: Forced air AIC energy source: Nt A Air conditioning type: Nj A Distribution system: Sheet metal ducts Brand 8L model: PORTER Location of filter s : FRONT OF UNIT 32) Recommend that this system be inspected, cleaned, serviced and repaired If necessary by a qualified heating and cooling technician annually in the future. Attic t..#~.lIn"un' ...a....r....t1..""t nm...../"lun..nIT TRPR A 07?LI.?OOLl./ 7/27/2004 Olympic Peninsula Home Inspection Inc.. Report Page 60f8 Inspection method: Viewed from hatch Roof structure type: Trusses Ceiling structure: Trusses Insulation material: Rockwool loose fill Insulation depth: UNKNOWN Insulation rating: UNKNOWN Insulation estimated R value: UNKNOWN Plumbing and laundry Location of main water shut-off valve: 8TH STREET Location of main water meter: 8TH STREET Location of main fuel shut-off: WEST SIDE OF HOUSE Visible fuel storage systems: ABOVE GROUND FUEL TANK Water service: Public Service pipe material: Galvanized steel Supply pipe material: Galvamzed steel Vent pipe material: Galvanized steel Drain pipe material: Galvanized steel Waste DiDe material: Galvanized steel ~O 33) Some, most, or all of the water supply pipes in this structure are made of galvanized steel. Based on the age of this structure, these pipes may be nearing or may have exceeded their estimated useful life of 40 and 60 years. Internal corrosion and rust can reduce the inside diameter of these pIpes over time, resulting in reduced flow and eventually, leaks. The inspector performed a "functional flow test" during the Inspection where multiple fixtures were run simultaneously, and found the flow to be adequate. For example, the shower flow didn't decrease substantially while the toilet was flushed. Despite thiS, and given their apparent age, these pipes may need replacing at any time. Basement Insulation material underneath floor above: Fiberglass roll or batt Pier or support post material: Concrete Beam material: Solid wood Floor structure above: Solid wood 'oists 34) This IS a root cellar and needs a new door. ~--__~_~ .______ ~___ ___ ___ ___~. ______~_M.___ ____.__ ____.__________________.~___ Crawl space Inspection method: Traversed Insulation material underneath floor above: Fiberglass roll or batt Pier or support post material: Wood Beam material: Solid wood Floor structure above: Solid wood joists VaDor barrier Dresent: Yes +"\ 35) Non-metallic sheathed wiring is unsupported or inadequately supported. This type G\ of wiring should be attached to runners or to solid backing with fasteners at intevals of 4 1/2 ft. or less. Recommend having a qualified electrician evaluate and repair as necessary . 36) Vapor barrier needs repair. Recommend repairing vapor barrier so no exposed soil Olympic Peninsula Home Inspection Inc.. Report Page 7of8 ~ , exists in the crawlspace. Recommend uSing 6 mil polyethylene with seams overlapped at least 24". ~ 37) Some insulation in the crawlspace has fallen down. Recommend reinstalling or replacing this insulation. ~ ~ 38) Wood scraps found in crawl space. Recommend removing to avoid attracting wood destroying insects. ~ & 39) Soil IS In contact with wooden support posts. Recommend grading soil so at least 6" of space between the support posts and the soil below exists. 40) EVIDENCE OF PAST POWDER POST BEETLE INFESTATION. ROT DUE TO MOISTURE IS EXTENSIVE THROUGH OUT THE POST AND PIER FOUNDATION SYSTEM FOR THIS DWELLING. 70 PERCENT OF THE PIERS AND COLUMNS HAVE BEEN EFFECTED. 70 PERCENT OF THE FRAMING HAVE BEEN EFFECTED AND 50 PERCENT OF THE MAIN SUPPORT BEAMS. Interior rooms +~ 41) Relatively few outlets are Installed in one or more interior rooms. This can result ~ in "octopus" wiring with extension cords, which is a fire hazard. Recommend having a qualified electrician evaluate and install additional outlets as necessary and as per the current National Electric Code. .~ 42) 2-pronged outlets rather than 3-pronged, grounded outlets are installed In one or ~ more interior rooms. ThiS limits the ability to use appliances that require a ground (computers and some other electronic appliances) in these areas. If client intends to operate electronic devices requiring a ground, then recommend having a qualified electrian evaluate and install grounded outlets where necessary and as per the current National Electric Code. +~ 43) No ground fault circuit interrupter (GFCI) outlets Installed. GFCI outlets help prevent electriC shocks in areas that may have water present. Recommend having a qualified electrician install one or more GFCI outlets, especially over counter tops and around sinks. 1mID~ 44) Few outlets and 2-pronged outlets rather than 3-pronged, grounded outlets are ~ installed in one or more interior rooms. This can result in "octopus" wiring with extension cords (a fire hazard), and limits the ability to use appliances that require a ground (computers and some other electronic appliances) In these areas. Recommend having a qualified electrian evaluate and install additional outlets and grounded outlets where necessary and as per the current National Electric Code. ~ & 45) No exhaust fan is installed in the laundry room. ThiS can lead to excessive accumulation of moisture. Recommend having a qualified contractor install an exhaust fan with a timer, duct and vent cap as per standard building practices In the laundry room. ~ 46) ALL Screen(s) missing in one or more windows. Window(s) may not provide ventilation during months when insects are active. Recommend installing screens. ~ 47) ALL Window(s) stuck shut and can't open. Recommend repairing window(s) so they open easily. ~ 48) EAST SIDE Door binds in Jamb and IS difficult to operate. Recommend repairing door so it opens and closes easily. ~ 49) Carpeting in living room IS loose. Several holes. Recommend having a qualified carpeting installation contractor restretch carpet as necessary. ~ 50) Wood flooring in bedroom worn or damaged. The client may want to have this flooring refinished and/or repaired. , 51) Wlndow(s) broken. PANTRY WINDOW AND BEDROOM ON THE WEST SIDE. ,. ,. II ~1 / 1 IT TT"'\."""y" ... A"""" III 1"'\ ^^ A J ~lymplc Peninsula Home Inspection Inc.. Report Page 80f8 Recommend replacing glass. ~ i 52) Caulk below shower at floor IS deteriorated. Recommend removing old caulk and applying a new bead of tub-tile caulk where shower meets flooring to prevent water damage to floor materials. ~ 53) Weatherstnp around one or more exterior doors is missing. Recommend installing -- - weathefstripping at-exterior doorEs) -where mIssing. 0 54) Minor cracks found in ceiling. These are only a cosmetic concern. No action is recommended. 0 55) Minor cracks found in walls. These are only a cosmetic concern. No action IS recommended. Your default report footer here... Powered by This report was published with ReportHost[ the premier web-based inspection report REPORTHOST writing service. For more Information visit httQ.;.jJwww.reporthost.com httn'//ululul f"pn"rlh"d (,"TY\/"hrnpnlT TP.PD ,\(l7,)Ll')(l(lLlI '7/')'7 /'){){) A J/ .L;.r \. E_~~ , ,-, I ~ '" ..... ,-"~ ~ '" .. - g ...,1 e?r5 / / / '6; De ~ ~~r' . n Application pin number Property Address ASSESSOR PARCEL NUMBER: Application type description Subdivision Name Property Use Property Zoning . . Application valuation CITY OF PORT ANGELES PUBLIC WORKS - ELECTRICAL DIVISION ~21 EAST STH STREET. PORT ANGELES. WA 91lJ62 V--:J: vvvvv....."":I:V .L..I"-Al...l;;; ~/.:Jv/U:J ~ 579760 536 W 8TH ST 06-30-00-0-2-6334-0000- RES ADDITION COMMERCIAL NEIGHBORHOOD 20000 ~ ~ ~ Owner Contractor ENGLISH, MONTE/LESLIE 255432 HWY 101 EAST PORT ANGELES (360) 452-2500 Structure Information Construction Type Occupancy Type Other struct info OWNER WA 98362 000 000 281 SF ADDITION TYPE V NON-RATED SINGLE FAM & CONGREGATES TOTAL % LOT COVERAGE CONST~CTION TYPE HARD SURFACE AREA NUMBER OF STORIES EXISTING LOT COVERAGE. LOT SIZE PROPOSED LOT COVERAGE TOTAL LOT COVERAGE NUMBER OF UNITS 27.60 V-N 2.00 1657.00 7000.00 281.00 1938.00 1. 00 Pe rmi t . . . . . Additional desc . Permit pin number Sub Contractor Permit Fee Issue Date Expiration Date ELECTRICAL ALTER RESIDENTIAL ROHWEIN/ 200A SERVICE 45419 ROHWEIN ELECTRIC 66.90 3/24/05 10/19/05 Plan Check Fee Valuation .00 o t \1\ ~ ~ .......J i " ~ 0<\\ I () ~ l/\ l~ ~". -:/ ---------------------------------------------------------------~------------ Qty 1. 00 Unit Charge Per 66.9000 ECH EL-R OR RM 0-200 ALT SRV FDR Extension 66.90 - - ---- -- ----------- -- ---- - - -- - - -- - ---- ------------ -- - --- - -- ------- --- ----- Special Notes and Comments When roof gutters are installed, drains will located in dry wells or piped to approved storm drain locations. The proposal will result in a 281 s.f. addition and foundation/roof repair to a s.f. residence for total lot coverage of'28% . Setbacks are good. No land use issues are noted. ------------------------------------------------------- Other Fees STATE SURCHARGE 4.50 --------------------------------------------------------- Fee summary Charged Paid Credited Due Permit Fee Total pran Check Total Other Fee Total Grand Total 66.90 .00 4.50 71.40 66.90 .00 4.50 71.40 .00 .00 .00 .00 .00 .00 .00 .00 COMMENTS/ACTION NEEDED \ ELECfRlCAL PERMIT INSPEQJON RECORD CALL 417-4735 FOR ELECTRICAL INSPECTIONS: PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNl.A WFUL TO COVER, INSULA TE OR CONCEAL ANY WORK BEFORE IT IS INSPECTED AND ACCEPTED. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE I INSPECTION TYPE DATE ACCEPTED COMMENTS r YES NO ./;tn;;~ 1(-. Pff 11i:'f'rt:'~'o. ~V~~OL0( 3) UlICH I (2) -c..'\/;-..) 1 b..:.. ~. lH)T l{ ~H-IN7 (.;UV,bK I?~~. J~ /'1Ct!7 SERVICE I ; GENERAL COMMENTS: PW -1102.1' (41961 '~ ti CITY OF PORT ANGELES PUBLIC WORKS - ELECTRICAL DIVISION .l21 EAST 5TH STREET. PORT ANGELES. WA 91lJ62 Application Number pin number Property Address ASSESSOR PARCEL NUMBER: Application description Subdivision Name Property Use Property Zoning . . . Application valuation 04-00000948 Date .579760 536 W 8TH ST 06-30-00-0-2-6334-0000- RES ADDITION 3/24/05 COMMERCIAL NEIGHBORHOOD 20000 Owner Contractor ENGLISH, MONTE/LESLIE 255432 HWY 101 EAST PORT ANGELES (360) 452-2500 Structure Information Construction Type Occupancy Type Other struct info OWNER WA 98362 281 SF ADDITION TYPE V NON-RATED SINGL~FAM & CONGREGATES TOTAL % LOT COVERAGE CONSTRUCTION TYPE HARD SURFACE AREA NUMBER OF STORIES EXISTING LOT COVERAGE LOT SIZE PROPOSED LOT COVERAGE TOTAL LOT COVERAGE NUMBER OF UNITS 27.60 V-N 2.00 1657.00 7000.00 281.00 1938.00 1. 00 -------~-------------------------------------------------------------------- Permit Additional desc Sub Contractor Permit Fee Issue Date Expiration Date ELECTRICAL ALTER RESIDENTIAL ROHWEIN/ 200A SERVICE ROHWEIN ELECTRIC 66.90 Plan Check Fee 3/24/05 Valuation 9/20/05 .00 o Qty 1. 00 Unit Charge Per 66.9000 ECH EL-R OR RM 0-200 ALT SRV FDR Extension 66.90 ---------------------------------------------------------------------------- Special Notes and Comments When roof gutters are installed, drains will located in dry wells or piped to approved storm drain locations. The proposal will result in a 281 s.f. addition and foundation/roof repair to a s.f. residence for total lot coverage of 28% . Setbacks are good. No land use issues are noted. ---------------------------------------------------------------------------- Other Fees STATE SURCHARGE 4.50 Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- P~rmit Fee Total 66.90 66.90 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 4.50 4.50 .00 .00 Grand Total 71.40 71.40 .00 .00 COMMENTS/ACTION NEEDED ELECfRICAL PERMIT INSPE(i.lON RECORD CALL 417-4735 FOR ELECTRICAL INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLA WFUL TO COJlER, INSULA TE OR CONCEAL ANY WORK BEFORE IT IS INSPECTED AND ACCEPTED. INSPECTION TYPE DATE I ACCEPTED COMMENTS I YES I NO DlTC;H IH1\ J{iH-IN / l.} H'....1.l 5'/9 /()~ /kD _ ~_ ,'\,J ",Lj,L" ~b.K VIeb -, rrnAL KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE GENERAL COMMENTS: PW.II02.15 (4196) v'b (:Y ELECTRICAL WORK PERMIT APPLICATION o Request Inspection , r i o Electrical Contractor o Annual Permit 0 Alarm 0 Carnival 0 Commercial f;t.Residential 0 Residential Mainl. 0 Signs 0 Thermostat 0 Telecom. Job wired by \J'Electrical Contractor 0 Owner Installation description COJl'fl'te,.e ~ ~ j4Uf<~I>t~,.J'I ~~(' ~N~C,.p Electrical contractor name :;:;0 ~ Purchaser's mailing address P<S- S ~..r ~ d,':c. License number l0ew H~'f 10 I "" ""-- Slate ZIP r", c.oall "Cvir Telephone number ~77 <i ~ "'h.x number ..760 :J2-Z..ro 0 o"v(r) W ~.t.p ,....~ .5 "' City 1(fi?6 C " \' Premises owner's name /lfOr->'T F Address of inspection s;; ~ ...6;j :41r EN t5'~ /J If di City o Cash p! Check # I hereby certify that I am the owner of the above named property or a licensed electrical contractor (or the firm's authorized agent) and am making the electrical installation or alteration in compliance with the clectricallaw, Chapter 19.28 RCW. o Credit Card Card # Visa Mastercard Discover Signalure or owner, eleclricaJ contractor or electrical administralor X ,~ 3-1l~<JS- Expiration Date of card Inspection fee $ (pfe:, 0 /' WALLS Insulation Only Dale Approved By Cover Date Approved By "- /' CEILING Insulation Only Dale Appro.'cd By Cover Dale Approvcd By THERMOSTAT Dale Approvcd By DITCH Date Approved By /~, SERV/~ q.L/ ~j)S " ,,v \. Date Approvcd By /' FEEDER "- Dalc Approved By Electrical Load Additions and or subtractions D NO LOAD CHANGES o Baseboard KW o Furnace KW o Heat Pump Ton LAR ~ Fan-Wall KW Service Information ~ Overhead Service o Temp Service o Underground Service Voltage Phase ~ D 3 Service Size: z..N'1 Feeder Size: Inspection Datc Area, Building or Equipment Inspected Action Taken Electrical Inspector p,,; dJO A-/P/J ? Ii.,. L ~