Loading...
HomeMy WebLinkAbout205 E 8th St "B" - Building ~ pORT ~ ~ ~ 'L ~ ~ "l.rO:~ CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY DEVELOPMENT - BUILDING DIVISION 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Application Number P~n number Property Address ASSESSOR PARCEL NUMBER: Tenant nbr, name Applicat~on description Subdivision Name Property Use Property Zoning . . . Application valuation 04-00000316 Date .361484 205 E 8TH ST B 06-30-00-0-2-3064-0000- HACIENDA COMM NEW CONST COMMUNITY SHOPPING DISTR 35000 4/20/04 AHA:tEO ~/{t1/ tJ4 WA 98343 1. 00 V-N 1.00 1. 00 1. 00 1. 00 1. 00 1. 00 335.24 35000 Extens~on 414.75 101.00 .00 o Extension 47.00 21.00 4.50 ~ ~ Vii \\"1 ~ '-f.. ~ UJ ':'J. ,.. t;J .... Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. ThiS permit becomes null and void If work or construction authorized IS not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined thiS application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether speCified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. /7 Owner Contractor ERICKSON DAVID K 144 THOMPSON RD PORT ANGELES Structure Information Construction Type Occupancy Type Other struct info CRESCENT DEL. INC. P. O. BOX 41 JOYCE (360) 928-2560 TENTANT IMPROVMENTS TYPE V NON-RATED BUSINESS:OFF/PRO/MED/REST TOTAL % LOT COVERAGE CONSTRUCTION TYPE HARD SURFACE AREA NUMBER OF STORIES EXISTING LOT COVERAGE LOT SIZE PROPOSED LOT COVERAGE TOTAL LOT COVERAGE NUMBER OF UNITS WA 983639740 Permit BUILDING PERMIT - COMMERCIAL Add~tional desc Permit Fee 515.75 Plan Check Fee Issue Date 4/20/04 Valuation Expiration Date 10/17/04 Qty Unit Charge Per 10.00 BASE FEE 10.1000 THOU BL-25,001-50K (10.10 PER K) Permit Additional desc Permit Fee Issue Date Exp~ration Date PLUMBING PERMIT 2- SINKS, 1-FLOOR 68.00 4/20/04 10/17/04 DRAIN Plan Check Fee Valuat~on Qty Unit Charge Per BASE FEE 3.00 7.0000 ECH PL- EA.FIXTURE ON ONE TRAP Other Fees STATE SURCHARGE Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Perm~t Fee Total 583.75 583.75 .00 .00 Plan Check Total 335.24 335.24 .00 .00 Other Fee Total 4.50 4.50 .00 .00 Grand Total 923.49 923.49 .00 .00 '1- zo - 04 ature of Contractor or Authorized Agent Date Signature of Owner (if owner IS builder) T\PLANNING\FORMS\1102 15 [11/14/20031 Date BUILDING PERMIT INSPECTION RECORD CALL 417-4815 FOR BUILDING INSPECTIONS CALL 417-4735 FOR ELECTRICAL INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED COMMENTS YES NO FOUNDATION: FOOTINGS WALLS FOUNDATION DRAINAGEfDOWN SPOUTS ELECTRICAL (LIGHT DEPT) SEPARATE PERMIT # ROUGH-IN I PLUMBING UNDER FLOOR / SLAB ROUGH-IN WATER LINE (METER TO BLDG) GAS LINE BACK FLOW / WATER AIR SEAL WALLS CEILING I FRAMING JOISTS / GIRDERS SHEAR W ALL/HOLD DOWNS WALLS / ROOF / CEILING DRYW ALL (INTERIOR BRACED PANEL ONLY) T-BAR INSULATION SLAB WALL / FLOOR / CEILING I I MECHANICAL HEAT PUMP GAS LINE WOOD STOVE / PELLET / CHIMNEY HOOD / DUCTS PW UTILITIES / SITE WORK (Engmeenng DIvIsIon) SEPARATE PERMIT #'s WATERLINE / METER SEWER CONNECTION SANITARY STORM PLANNING DEPT SEPARATE PERMIT #'s SEPA. PARKING/LIGHTING ESk LANDSCAPING SHORELINE FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED YES NO ELECTRICAL - LIGHT DEPT 417-4735 ELECTRICAL LIGHT DEPT CONSTRUCTION R W / PW/ CONSTRUCTION - R. W ENGINEERING 417-4807 PW / ENGINEERING FIRE 417-4653 FIRE DEPT PLANNING DEPT 417-4750 PLANNING DEPT I I BUILDING 417-4815 BUILDING ~/q /a1 T \PLANNINGlFORMS\ 1102 15 11/14/2003 I PREPARED 8/19/04, 15 23 29 CITY OF PORT ANGELES INSPECTION TICKET INSPECTOR JAMES L LIERLY PAGE DATE 2 8/19/04 ADDRESS TENANT, NBR. CONTRACTOR OWNER PARCEL . APPL NUMBER 205 E 8TH ST B HACIENDA CRESCENT DEL INC ERICKSON DAVID K 06-30-00-0-2-3064-0000- 04-00000316 COMM NEW CONST SUBDIV PHONE PHONE (360) 928-2560 ------------------------------------------------------------------------------------------------ PERMIT: BPC 00 BUILDING PERMIT - COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL99 01 ~ ~ -----------~~~~~--~~----------------- BUILDING FINAL COMMENTS AND NOTES ------------------------------________ . ~ I} 4 ' . liT 10 r'" lil'T:' D I" ~ "<' P~! .:.du !h,1! (/lIr.' Jj:UO .1', , . Cfrv OF PA BLDG DEPT FAJ Nn, ?fjlj 4: ~ 47;] P 001/00: ,BU:ILDJItlGB "~ ,~-"-,-:,;,:V ~t::,;'{r.{~~~?~~:~:SfJ.:::~1 ~2~~j~~(~~~1~1_~: Fill out comt.E'ri:Lv :'Dd;fi'lNI~:' " "~:;~P.,. ..",: '>"i(i COM:PLE'1'E to b~ ac:eepted for review. ltyou'baye:'any. (360) 417-4815 , "/'1 'I , :1 AwJreant '" ~ ~ecfn.\- O=.J :FIl):>IIh~.\- :z;;~' PhoDe 3100 em 3?,Q ~ Owner: ~O~ l:IOC-feJ1dQ - SPf010 \<:>505 Phone: 4~;2 -Joq5(P Address: <g J 7 S, LaL~ f.s\-. City:]by+ An~I~ . Zip: qSBlo'2. ArchitectlEngineer: Phonc: (j fr. l k C O/C lDUS":& Pr7' , Contractor ()/<{lP..t\'t; ve DfMellt 'l'.StateLicense#: f<.l3Sc~IIFxp: 03'{)~- Phone: C"l :&3510 Add<oos: Th ~ ~ aty:~ . "$po ljj(3l{3 _ PROJEcr ADDRESS: Cf=':> 6:.. ~ SA. l (11'A-~iol_ ~_,~~ ' . 'LEGAL DESCRIPTiON: LotJl)-\1- Block: ~ Subdivision: - N~::;:::\'~",.:'::' CLAll.AM COONTYl'ARCBLNUMBER: CXo - 3\;) -Dl1- 0 - 2- ~M ..:~: Credit Card Holder Name: BilliDg Addl'fft: CreditCanlType ~MC _ if TYPEOFWO~ o Residential P--::New COn.s1r. 0 Re-roof o Mu~famil.y C Addition CI Move fl Co~ C Remodel 0 D~moliti.on o Repair 0 Sign DlUEFDESClUPTION OF THE PROJEer: City: Eq. Date: SIZE,V ALU.AnON: o Stove SF. @ S ISF. :;; $ o Garage SF. @ $ /SF. _ $ o Deck SF.@$ ISF.=$ a Othm~ TOTAL VALUATION $ 15:000 yYlE} jCM ?ps,~~~vt- sv..Hp -.8 / ~~~.sfJ4<'es COMMERClALIRESIDENTIAL: Occupancy Group.: occupant Load: No. ofStorios: i Lot Size: Ex:lsting Sq. Ft. & Proposed Sq. Pt. ExistiIIg lot coverage _ % & Propo:se<! lot COV~ _% = Total lot coverage Construction T'jpe:~fJ(;-J = TOTAL Sq.Ft 1-'100 % '" APPROVALS: PLAN: BLDG; DPWU: :FIRE: OTHER;_ PLANNING USE ONLY:' BSAlWctland(s): 0 Yes 0 No SEPA Cbecklist required? t:J Yes 0 No OlUr. BtTILDlNG PERMIT APPLICATION SUBMITTAL: The Building DiVISion can p:r:ovide you with mfO%1XlBtJ.on Ou the applianion and plan submittal ~ lfyou have qusstiOl16. VALUATION OF CONSTRUCTION: Iu all cases, a "fuuation amount must be entered by the applicant. Th.is figure will be reviewed udmaybe revised by the Building DiviSIon to comply W11h cw:z:entfee schedules. Co;war;tthePcm:1it Coordinatorat417-4815 foJ assistance. PLAN CHECK FltE: IF a plan clJ.eck tee is due it mu.st be submitted at the time the building pem1lt applicati.on 8D.d construction plans axe mbmi:ttr.d All otha.r pe:tmit,.fees are due at"the tUne of pennit usuance. ExPIRATION OF ~LAN REVIEw: If no pcnmt 1S issued within 180 dayi oftb.e date of applicatw1l" the appJiclltion will expire. The BuUdmg Official can extcDd the tim.eI for action by the applioaDt up to ISO days upon wtit1ED request by the applicant (see Section] 07.4 cf the Uaifonn Building Code. cmreat edition). No application can be extended l1J.oX'e than once. I hereby cel1ffy that I have read end &xaminsd this ~pplJeafion and know thfl came to be true and COlT9ct. J am auttJori;zsd to apply for this permn. and undemand that it is my responsibJlfty to determine What parmits are ~iJilJ!f!. ,~t the gty's, 8fICi that I mll5f obf8in such pe~ prior _to work T,""'""",^",..........,J,..;,wp. ApPIic"'~ auf! j? D,,",:3 2'2 (j( "'-. 30':"6. 4''':'0. 4''':'0. '-a" '3'-4" '15'-0. '19'-6" 40'-0" '1/"L -u -122'-0. '20'-10" ET AIL A CITY OF PORT ANGELES - Construction Plans The Issuance of this permit based upon these plans, speClfi. cations and other data shall not prevent-the-bUlldmg official from thereafter requiring the c()rrecbon of errors in said plans, specifications and other data, or from preventing building operations being carned on thereunder when in Violation of all codes and ordinances of this jurisdlct (SECTION 303(c). mform BUll Ing Code.) Approval Date \) By 0'-0" 2"-0". ~:J. 5lCS?J '20'-9" . I ! , --::? '-3" -( i0~ _. . '-6" n '33'-9" I: , i r ~. <\ \~. I I. I / J' ;')"; , r i -~'\ -~::--- :-:~'; ~ - I ll:::::-f~ D ~ lI'4 ~' I ,a: ~'':!.. :r~ 'ft ~.1. ~~, ""." f'; ~~. Zf. ~"- S ;:.~, - 1? .--- 2.( ( - bl2J FILE .' /AeL($ '\ .... '-0"1'-5"- '-0" '-O"r'-O. '7'-7" '0 FLOOR SCALEJB" = 1 ' ~""", ~;f:~" ": ~ , , ' ~' ORT'P;.NGE'LE'S' ; ~; f ;:',' : 1 / l' ~ ~ j; i ~ ~> ' ! ~:;.vr' i > r~~ _ '~_j } , ( ,,,,'/ i ! " , WAS H I N G TON, U. s. A. . --~u e bl G--WO RKS-&--UT I.b-I-T~ES-D E-PART-M-E-N.::r: February 4,2004 David K Erickson 144 Thompson Rd Port Angeles, W A 98363 RE: 205 East 8th Street water meter installation Dear Mr. Erickson This letter is in regards to your request to place new water meters / service lines on the north side of your new building being constructed at 205 East 8th. As you know the old water service meter locations were on 8th Street. Upon your request your water service for the new building will not be served by the 8th Street meters. As a result of the excavation-demolition ofthe former building the City's water division removed one (1) servic,e. The existing concrete sidewalk along Lincoln Street and 8th Street have several areas in need of removal and replacement. Due to the improvements required for the sidewalk areas, the installation of any new meters / service lines will be after you remove the concrete material. All sidewalk or driveway approaches are to be brought to City design standards. The installation fees for the water meters are based on the size requested. The meters will be placed within the City's right of way on Lincoln Street. At this time, my understanding is that you are requesting three (3) water meters of which (2) will be the standard 5/8" size, and (1) 1" for the proposed restaurant. The fees for the 5/8" size will be $640.00 each and the 1" $1000.00. If you have questions, feel free to contact me at 417-4807. Sincerely, J/LfAqit ~ Trenia Funston, Engineering Permit Specialist cc. Department of Conununity Development Buildmg FIle Water DIVISIOn 321 EAST FIFTH STREET · POBOX 1150 · PORT ANGELES, WA 98362-0217 PHONE 360-417-4805. FAX 360-417-4542 · TTY 360-417-4645 IE-MAIL' PUBWORKS@CI PORT-ANGELES.WA US , ~ \J\ \\\ 1 I /' / .......... j ~ CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY DEVELOPMENT - BUILDING DNISION 32] EAST 5TH STREET, PORT ANGELES, WA 98362 Application Number pin number Property Address ASSESSOR PARCEL NUMBER: Tenant nbr, name Application description Subdivision Name Property Use Property Zoning . . . Application valuation 04-00000567 Date .029203 205 E 8TH ST B 06-30-00-0-2-3064-0000- SERGIOS HACIENDA 6/28/04 SIGNS COMMUNITY SHOPPING DISTR 3010 Owner Contractor ERICKSON DAVID K 144 THOMPSON RD PORT ANGELES WA 983639740 THE SIGN STORE 22 MILL RD. SEQUIM, WA SEQUIM (360) 383-6655 WA 98382 Permit Additional desc Permit Fee Issue Date Expiration Date SIGN 1 36 SF LIGHTED 85.00 6/28/04 12/25/04 SIGN Plan Check Fee Valuation .00 3010 ~ 0 Ci'J "!\ 0-, <: ,J::> CD ~ .,.... $ (/\ }:. ~, it fJ\) Qty Unit Charge Per 1.00 85.0000 PER S- SIGN WALL 25 SF+ Extension 85.00 Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 85.00 85.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 85.00 85.00 .00 .00 Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction orwork is suspended or abandoned for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Signature of Owner (if owner is builder) Date T:\PLANNING\FORMS\1102.15 [11/14/2003] BUILDING PERIVIIT INSPECTION RECORD CALL 4] 7-48]5 FOR BUILDING INSPECTIONS. CALL 4] 7-4735 FOR ELECTRICAL INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCA nON. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE. INSPECTION TYPE DATE ACCEPTED COMMENTS I YES I "V FOUNDATION: FOOTINGS WALLS FOUNDATION DRAINAGE/DOWN SPOUTS ELECTRICAL (LIGHT DEPT) SEPARATE PERMIT: # ROUGH-IN I PLUMBING UNDER FLOOR 1 SLAB ROUGH-IN WATER LINE (METER TO BLDG) GAS LINE BACK FLOW 1 WATER AIR SEAL WALLS CEILING I I FRAMING JOISTS 1 GIRDERS SHEAR WALL/HOLD DOWNS WALLS 1 ROOF 1 CEILING DRYWALL (INTERIOR BRACED PANEL ONLY) T-BAR INSULATION SLAB WALL 1 FLOOR 1 CEILING I I MECHANICAL HEAT PUMP GAS LINE WOOD STOVE 1 PELLET 1 CHIMNEY HOOD 1 DUCTS PW UTILITIES 1 SITE WORK (Engineering Division) SEPARATE PERMIT #'5: WATERLINE 1 METER SEWER CONNECTION SANITARY STORM PLANNING DEPT. SEPARATE PERMlT #'5 SEPA: P ARKING/LIGHTING ESA: LANDSCAPING SHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED YES NO ELECTRICAL - LIGHT DEPT. 417-4735 ELECTRICAL LIGHT DEPT CONSTRUCTION R.W.I PWI CONSTRUCTION - R.W. ENGINEERING 417-4807 PW 1 ENGINEERING FIRE 417-4653 FIRE DEPT. PLANNING DEPT. 417-4750 PLANNING DEPT. BUILDING 417-4815 :(- fJf) -O"'l .\ 1-L BUILDING T:\PLANNING\FORMS\I 102.15 [11/14/2003] BUILDING PERMIT - APPLICATION FOR OFFICIAL USE ONL Y:l1 Date Rec.:~ -29 -6J Permit#:04 -5b7 Date Approved: Date Issued: ' Fill out COMPLETELY and in INK. Your application and site plan MUST BE COMPLETE to be accepted for review. If you have any questions, call (360) 417-4815 , , '\ Applicant or Agent: ?-e y!]r, 0/"> H V\ CI-eY\ d a-.... Owner: Sf/If ~x I " 63 c:{ J J -l' <:EZ~ Address: f) oS-;;: ~.J..~ s -trc-<"# ity: ~Q'f l- Architect/Engineer: Phone: Phonel36 0 )(( S g.- b 9-<; G 'A-/\fj -c I ~ ~ Zip: Cf 0- :) b:J Phone: Contractor State License #: Exp: Phone: Address: City: PROJECT ADDRESS: 3. ll') c:;- t::: g+~ ;) ~.e T -::;:t f3 Zip: ZONING: (LJr LEGAL DESCRIPTION: Lot: Block: CLALLAM COUNTY PARCEL NUMBER: Subdivision: Credit Card Holder Name: Billing Address: Credit CardType VISA MC # TYPE OF WORK: o Residential 0 New Constr_ 0 Re-roof 0 o Multi-family 0 Addition 0 Move 0 o Commercial 0 Remodel 0 Demolition o Repair 0 Sign BRIEF DESCRIPTIiN OF THE PROJECT: I I. ) City: Exp. Date: SIZEN ALUATION: SF. @ $ /SF. = $ SF.@$ /SF.=$ SF.@$ /SF.=$ TOTAL VALUATION $~0 -:t<; 1\/ '0' ' 6 COMMERCIAL/RESIDENTIAL: Occupancy Group: Occupant Load: No. of Stories: Lot Size: Existing Sq. Ft. & Proposed Sq. Ft. Existing lot coverage _ % & Proposed lot coverage _% = Total lot coverage Construction Type: ESAlWetland(s): 0 Yes ~~ SEPA Checklist required? 0 Yes r;vffc, Other: APPROY ~,~~, i PLAN:~ BLDG: DPWU: FIRE: OTHER:_ .:J "-... ~ "rl' ~' . 'I' , ' . PL G USE ONLY: ' J J .' " / 'J" M' '- ~... ,.' (~OY /f) ~ / r~)j~~ ~J 0 -::.~ 1;:J j'-- :! ::; :~,1 - - b'iliP ~ : ~:'f': .~~, ,:~ BUILDING PERMIT APPLICATION SUBMITTAL: The Building Division can provide you with information on the application and plan submittal requirements if you have questions. VALUATION OF CONSTRUCTION: In all cases, a valuation amount must be entered by the applicant. This figure will be reviewed and may be revised by the Building Division to comply with current fee schedules. Contact the Permit Coordinator at 417 -4815 for assistance. PLAN CHECK FEE: IF a plan check fee is due it must be submitted at the time the building permit application and construction plans are submitted. All other permit fees are due at the time of permit issuance. EXPIRATION OF PLAN REVIEW: Ifno permit is issued within 180 days of the date of application, the application will expire. The Building Official can extend the time for action by the applicant up to 180 days upon written request by the applicant (see Section 107.4 of the Uniform Building Code, current edition). No application can be extended more than once. I hereby certify that I have read and examined this application and know the same to be true and correct. I am authorized to apply for this permit and understand that ff is my responsibilffy to determine what permffs are required ,not the Ci~at 1 must obtain such permits prior to ~rk. T:\FORMS\APPS\BuiIdingpermit.wpd Apphcant: 4 - &IJ. "1 Date: 06, 2 g 0 y ~ z ~ ri -:;J tS ~~ -ad .~ ~ \,) 0 ~_ \J -L_ '~ ...Vi c) .~E , "- ~ , (J QJ \.L 'f) ~ ;;r; - ~ - (() J ~ ~ o - ~ ~ .... ... - ..... 5 ~ ~ ~ .~.5.. ~ s: ~~s:~ai~ c <A" ~.- a; ~ '5i .2 <='- ~ a 'C " t) -a;:g g ~.=. ~ ~ Q,)..QCDEc:sa ~Cl)_g:3:.c: .c;..c::: Q ~..... S ~:::::sS::sC5"""":'" () 8.~:;:;.ric:~~ I =CL:l~ct1ou8 ;>.. m ~.: 8 ~ :::~!f ~t:rl .... J!l <=J!"'" ~'P:E "" w;t:~""'o~o~'J Cl E.c "" "0 "" "0 ' Z ~ ., .<= c: c:: c:: E .." c( ~ ~.E":; (\:J Ow C1;J 0 ~ I- .~ {l g. ~ .c ~ 'E Nj ~ _ Q,) c.n"O::J o =is ~ :: ~ .~ 8 . ~ Q. ClJo:E..g~=~~ u.. g "C ~ 'u Cl.:> ro 0'_; <l.> o ~~~~g.o~ ~ >- J!! g :E :~S? 2 ~ t: a.;.'- E c ~ "'-' ;:~ -'. CJt="5e~~~Cw' t~ _ Q..J:J"S; ~ .g -z h-E '2V1~ " l- 6-l~ x::~Z ~~~ .JDJ\ ~ lD. 2 \D D <t ~ IJ\ < I- ti\ ~ \ \ ..J t.u ~ '"t \~ +- r< \j\ \J'i '3 rl ~ o ~ ~ t- -:< CD J \w \f;\ cD~ o ~8 '. '" I'~) ", '- ' ~ J \ ~ '\ \ '. " ", C'v. ;2' 1/ ~ -z: ::J z ~\ z .'. ~ ~IGN~& 'AWNINGS PC:>RT .A.Nc::;.ELES. ,^,.A.SHINc::;.TC>N Phone 360.417.9548 Fax 360.452.6nB l~"~IC' L 'Ql ~ ~- \ o--:=::- A {puB ~11$J c.o't S~~~Q~.. :':d~A~E:::~ ~ --- 1 j;/I;Vp:' M(;fU \V I~ (( a~G Slq~ 010 'br~T> " SEK.GIQ'S lA FAMilY MEXICAN RESTAURANT -Designs are a courtesy to our customers for the purpose of visual definition. They are kept in our records for up to 2 years. Until an order is placed for completion of job, designs are the sole property of Peninsula Signs & Awnings. Thank you for your kind cooperation. * CO\O(s c c1. \A. ~ clA.aM.~ f€.f ~S'l~ a.c.LC{'&\~ to color- f(e.WeMCe. OJ o-J '" I t' >< ~ I <0 '0 I <0 ...... I Ul H I 0 0 >i I >-' " I I C/) I I H I 8Gl1.! I I , ,.., 3:0 , , '" 'OC:o , -J t'OJo , ...... OJUl I o-Jo-JC/) , '" OJOJH , tJtJ1.! , , :i;c "' , t' OJH , t' UlZ , C:Ul t''O , o-J , OJ "'tJ 8 OJ OJ UlUl t' C:() tJ t'"' Z o-JH Ul'O () G"l ......o-J 0 ()H 3: '" 00 3: H 3:Z OJ Z 3: Z ~ OJ o-J t' Z Ul o-J Ul ~ tJ Z 0 o-J OJ Ul ~~~8~E;' 'O",zzZtJ ~Q~;ci~~ Zt' ~o-JUl c: ()- Ul 3: . o-J OJ oz tIj. . :;cl tJj. "' "' oottjl-3UJl\.) ~O'\::d:r::tIjo I I H tJ::I :.u Ln own (j) OO?':(()HJ:Ij o I (f) H 0 ooOG)(f}OO oozz l-3 lT11 :r:::r:: <J\otj(J):r:- -...]1~r-3(){J) rv<OHl-3 (J)tH:utIj HWt:ltI:lZtIl G"lo tJ z"'~ ~ Ul'" o o o o , '0'0 ~~ 00 zz OJ OJ ()'O H", o-JOJ ><'0 ~ 0"' "'OJ tJ '0 o "'''' o-J...... ~~ G"lo t'l'" t'- t'l Ul>-' W o '" >-' -J Ul c: OJ tJ H < H HZ ZUl Ul'O 'Ot'l t'l() ()o-J o-JH 00 ",Z yo-J ~~ t'l~ UlOJ o-J t' t' H 't'l w "' '" t' o >< w '" w '" '" '" '" tJ'O ~~ o-JG"l OJ OJ '" ...... '" -J ...... o "'''' en :J"tJ l:l) 0 C/) - ~ o 0 -~~ 0" - 0: ('!) :J S. ~. ('!) a; ('!)"Os 3 ~ a.. o CD ~ < 3 CD C/) 0.(1) (1) C/) >< -. o ~ .. CD Q,) "0 -0 0"0 '< ::J OJ~ :. o' -I: 0.0 ~ I: COC/) o "0 ~ ~ :::: Qi" .. ~ -'0 --l o CD ~ ~ o .j::.. co s. c:: 5 "" >- 0. =;- ~ N o VI t:d Pl CIl ..... 00 ..... ::r C/l ..... '"1 (t) (t) ..... '""0 o ::4.- ~ (t) - (t) CIl ~ > \0 00 W 0"\ N o ~ !1 o ...., co ~ 5' ~ C/l (t) g: Cl ..... ~ CIl ~ 0... t:d CIl '"1 (t) CIl CIl o >- 0. =;- D: ~ .....- N 0"\ ~ (t) CIl ..... .....- CIl ;+ C/l ..... '""0 o ::4.- ~ (t) (D' CIl ~ > \0 00 W 0"\ N Cl C3 t: ""! ~ (l; n [ =r; (") ~ o '" lea ~ (l; o ...., n o ~ '1 t: ~ o' ::l ~ -.~. ~ ;:::O'~ ("') ~ "" ~.3 (] ;:::t:o.~ 'i:5 :;:: ~. co ~ ~~ s. ~ -.2 ~ (\) ~ :::-. ~ ~. (] ~ :l ("') ;;. ~ t::;. ~. ~ -. (\) "" z ~ ~ ("')~ !" ;::l -< ~. l::l.. ;:; l:l~'\::l ~ ~ '-o::::} s::: ~. o. -. ~ ~ ~ ~ ~ S;; ;;. ~ l::l.. l:l ...... -. """"'" a !\l ;::: l:l -. l:l ...... ;::-. '"!j;::: ...... (\) co e ("') ;::-. ~ ~~~:':(\) oj" ;;. e -."::::' D: (\) <..::;., 3 E. "'z '":::::-, -. (\) ~ e ;:::-. e (\) 3 :::::: (\) <..::;., 3 ~ ~ Q E- ~ -.q:;:: "" C/l;::: l:l (t)~~;:::..9 - . ~ ("') -,., ~ :;:: (\) ft; -......("') Cl ~ ~:::-. _. 5' "" e ~ ()q ",,;::: CIJ .~ ~ Pl tx:I :;:: <:::> ::l E. Q \Q 0... E;::;:: e ...... -. ": <..::;., l"j ;::: (\) -. CIl ()q ~ ~ '"1 l:l (t) "" CIl CIl o :;;0 (t) ..... 8. - <: Z o .j::.. I we -~ oo~ ~ " N o ;:l ~ n Z '+~+O (j O='~ c'-< -. -c Q.~ ..... = '"'C (JQ C ~::4. :;. > ~. = -. (JQ C (t> = ~ rI) n m ::tJ ----t - ." - n )> ----t m o ." o n n c: -C )> Z n -< ~ :..~ ~ I'ORT ~ A..~O~~ (J f'i1!!iij<'", ...~ ~~ CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY DEVELOPMENT - BUILDING DNISION 32] EAST 5TH STREET, PORT ANGELES, W A 98362 Application Number pin number Property Address ASSESSOR PARCEL NUMBER: Tenant nbr, name Application description Subdivision Name Property Use Property Zoning . . . Application valuation 04-00000237 Date .117184 205 E 8TH ST B 06-30-00-0-2-3064-0000- HACIENDA DEL MAR INC HOOD/DUCT SUPPRESSION SYSTEM 5/06/04 COMMUNITY SHOPPING DISTR 14500 Owner Contractor ERICKSON DAVID K 144 THOMPSON RD PORT ANGELES WA 983639740 ALPINE FIRE & SAFETY SYSTEMS I P. O. BOX 265 BURLINGTON WA 98233 (360) 755-5444 Permit HOOD & DUCT SUPP SYSTEM Additional desc Permit Fee 40.00 Plan Check Fee .00 Issue Date 5/06/04 Valuation 0 Expiration Date 11/02/04 Qty Unit Charge Per Extension 1. 00 25.0000 ECH HOOD/DUCT INSPECTION/TESTING 25.00 1. 00 15.0000 ECH HOOD/DUCT PLAN REVIEW 15.00 ~ G \ S\ Permi t MECHANICAL PERMIT Additional desc Permit Fee 57.65 Plan Check Fee .00 Issue Date 5/06/04 Valuation 0 Expiration Date 11/02/04 Qty Unit Charge Per Extension BASE FEE 47.00 1. 00 10.6500 ECH ME-HOOD/DUCT SYSTEM 10.65 fl\ Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 97.65 97.65 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 97.65 97.65 .00 .00 \) - <. r ~ :! ..J Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of .cons,ruction. ! /. _ 4- ~!C'fff!L-q~ s-b- OL/ Signature G':,tractor o~onzed Agent Date Signature of Owner (if owner is builder) Date T:\PLANNING\FORMS\1102.15 [1111412003] BUILDING PERMIT INSPECTION RECORD CALL 4]7-48]5 FOR BUILDING INSPECTIONS. CALL 4]7-4735 FOR ELECTRICAL INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCA nON. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE. INSPECTION TYPE DATE ACCEPTED COMMENTS YES I NO FOUNDATION: FOOTINGS WALLS FOUNDATION DRAINAGE/DOWN SPOUTS ELECTRICAL (LIGHT DEPT) SEPARATE PERMIT: # ROUGH.IN I PLUMBING P, NIJ-L- r. rl-D 'I f}'() J. L.t. UNDER FLOOR 1 SLAB ROUGH.IN WATER LINE (METER TO BLDG) GAS LINE BACK FLOW 1 WATER AIR SEAL WALLS CEILING FRAMING JOiSTS 1 GIRDERS SHEAR WALL/HOLD DOWNS WALLS 1 ROOF 1 CEILING DRYW ALL (INTERJOR BRACED PANEL ONLY) T.BAR INSULATION SLAB WALL 1 FLOOR 1 CEILING I MECHANICAL r Il"'Itr'- (t. 'J..7-C1 .4-r J./... HEAT PUMP GAS LINE WOOD STOVE 1 PELLET 1 CHIMNEY HOOD 1 DUCTS PW UTILITIES 1 SITE WORK (Engineering Division) SEPARATE PERMIT #'5: WATERLINE 1 METER SEWER CONNECTION SANITARY STORM PLANNING DEPT. SEPARATE PERMIT #'5 SEPA: PARKING/LIGHTING ESA: LANDSCAPING SHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED YES NO ELECTRJCAL . LIGHT DEPT. 417.4735 ELECTRICAL LIGHT DEPT CONSTRUCTION R.W. 1 PWI CONSTRUCTION. R.W. ENGINEERING 417.4807 PW 1 ENGINEERING FIRE 4 I 7.4653 FIRE DEPT. PLANNING DEPT. 417.4750 PLANNING DEPT. BUILDING 417.4815 1t:l.-1J7 -o..J I .11 BUILDING T:\PLANNING\FORMS\l102.I5 [11/1412003] to ., 'tI ~~~8t;jE; n'tl t:-< ><: ~ H", '" '0 'tI",ZZZtJ >-lO1 '" , t<Q~~~Gi ><:'0 Ul H >> 0 0 >-l Zt:-< >>>-lUl 0"' H ~. n' Ul "'01 >-l tJ j "' to OZ '0 01, "' to . 0 ()::U~ "' "' ",00 001 >-l' 3:0 tv 'tICO OOtJj;p:::r::N ~~ , -.J t:-<010 ,p."'::dt'l~O , , O1Ul ' , HtO()lJl 00 d>--3lI:l OW()HH 01'" , ... ~~8 oo~ZtljtI:I t:-<- , o I {f) tr:l Z 01 tI 000 tJoo UlH , 00 Z "Ij;t:" 1-3 w ~ It' tv, H :0 "' wot:l::ut:l 0 O1HtI -.J , ):>Itl:ltI:lC/) ... UlZC: tv<=: t:-<>-l ~~Cl :0' Hi?' H OWtJ Ul~to -.J >-l 00 ij t:lm:;>;:~::d , ,... '" , tJ, O1H , 'tI Co >-lZ , to "'t:J nO ><n , S O101CfJ >-l0 UlUlO< 0 Ul t:-< , cnCfJ Ul , >< n tJ t:-<",>-l c: Ul 0 H ~~~ '0 >-l Z Z '0 01 >-l 0 '>-l "' 3: Z nH 01 Ul H '" 00 Ul HZ c: Z 3:Z Ul Z[J) 01 , 3: H [J)'t1 tJ >> 01 0 '001 t:-< Z Z O1n 0 >-l n>-l Z [J) [J) >-lH >-l >< 00 0 >-l [J) ",Z H >-l Z 3: 01 c..>-l 01 01 , 3: ~8 >< '0'0 [J) >-l :0:0 ii1 O1~ H 00 UlO1 '0 -.J ZZ tJ >-l >> 0101 < t:-< 0 0 01 0 t:-< H 01 w "' '" t:-< 0 >< -.J <n <n <n ... ... ... tJ'tI >>>' >-l0 0101 00 , tv -.J , 0 "'H 'U >-l '0 , )>'UOCl>-l)> , Cl'U t< >-< ~ , 'U)>:EOOJtJ , H;U '" 'U , 'U;UZZZtJ , >-lOJ '" , '-- , ~Q~;ciS;~ , >-<'U , UJ H , , )> 0 , ;:) .., , Zt< )>>-lUJ , O;U H , .. , ~. Cl' UJ , "'OJ , , >-l , tJ , '0 , to OZ , 'U , I:" , OJ. ;U to . , 0 Cl;U , ;U ;U , ;uoo , OOJ , .. , >-l'__ , 3:0 , , '" , 'UCO , OOtr:ln:I:N , ~-::. , t<OJO , .t>O'\::O::O~O , , OJUJ , , , HtI1()1Jl , Glo H~"tl , QWOC/)H , OJ., , OJ OJ I:" , OO~ntI:ltI:l , t<. , tJtJ~ , o I (j) tI:l Z , OJ , , ooOZt::lro , UJH Ltc , ooZH~"'" , w H , w , :I: ;U z: , I-'ot:lt::l , 0 trlHG':I , '" , )>OJ UJ , ., , t< UJZ , "'<t< >-l , , CUJ'O , Cl , H. H t<'U~ , OWtJ to , ..., , H , 3:0 H , , , :s:O'\~Z , H , ., Cl .., , Z , , , , OJo , 'U ;UtJ , :Eo , t< OJ OJ , 0 , , ~ UJUJ , Clo , CCl , 0 to t<;U , Z , , Z >-lH , UJ UJ'U , >-l Cl Gl '__>-l , , 0 nH , H 3: '" 00 , , HZ 3: Z 3:Z , , ZUJ OJ 3: , UJ'U Z )> OJ , , 'UOJ >-l t< Z , , OJCl UJ '" , Cl>-l UJ , "'H ~ , , 00 >-l , ;UZ tJ H , 3: c..,.., Z OJ , )>H 0 'U'U UJ 3:Cl >-l :I::I: C , OJ", OJ H 00 to , UJOJ UJ " ZZ tJ , >-l OJ OJ < , t< 0 , 0 .. , t< , H , OJ w , :u '" , t< 0 , >-< , '" '" 00 , , '" U1 , '" , 0 , , , , , , , tJ'U , )>)> , >-lGl , OJ OJ , , , , 00 , '-- , '" " , '-- , 0 , .,W 3: -l "', "''don...,,,, n'd OJ 0-< ~ 'd",:<;oOJo H", \0 'd 'd",zzzo ...,OJ \0 ...... ~Q~~~~ O-<'d (f) H '" 0 0 ..; ZI:-' ",...,(f) 0"' H ~. n- (f) "'OJ -l 0 ~ OJ OZ 'd OJ. "' OJ. 0 n", "' "' ",00 oOJ ..;...... 3:0 N 'dC::o ootI:l)::l~1'0 ~.::: I:-'OJo ol::>m::tlt:""'~o OJ(f) , , HI1j()lJ1 G)o ;;JtH OV.JnHH OJ'" oo~ZtI1tIj , 1:-'- , oo~ 0' (f)OJZ OJ , 000 000 (f)H , OOZ'"Ij~f-3 w N , H :r: "' H woO:::tlO 0 OJH~ -..] "'OJOJ(f) '" (f)Z N<: 1:-''''' C::(f) :r:, H'" H I:-''d owo (f)~OJ -..] '-'j '" 00 ~ t:lm?;::J::.'::d ......'" '" 0' OJH H C::O -lZ , 3: "'0"; no o-<n OJ OJ OJ ""0 n (f) en 0 (f) :r: c::n (f) , 0-< ~ 1:-'"' c:: (f) ...,H 'd ..., H (f)'d 'd OJ n n ........., "' 3: 0 '" nH OJ (f) H 3: I:-' 00 (f) HZ 3: 3:Z (f) Z(f) OJ '" 3: H (f)'d Z Z OJ 0 'dOJ ..., Z Z OJn (f) '" ..., n-l I:-' 'D (f) ...,H ~ 0-< 00 (f) "'Z 0 ..., ..., OJ ,-<..., Z H 3: ~~ 0 3: 'd'd (f) ..., OJ :r::r: 6i OJ?': OJ 00 (f)OJ (f) ZZ 0 ..., H OJ OJ H , I:-' -..] <: I:-' 0 H 0 OJ w "' '" I:-' 0 0-< -..] '" '" , '" '" '" '" O'd "'''' ...,G) OJ OJ 00 ...... N -..] ...... 0 "'N BUILDING PERMIT - APPLICATION FOR OFFIC~L USE ONL ~ :/ Date Rec.: t:J'j ~ J.';; -01. Permit #: Ot-t "- 237 Date Approved: Date Issued: Fill out COMPLETELY and in INK. Your application and site plan MUST BE COMPLETE to be accepted for review. If you have any questions, call (360) 417-4815 Applicant or Agent:~.f/wy", 0q (I ~()~ Owner: .5 i It /('V1w ?:; a /11!i!O) Address: 910 S- 50 de g City: PI'V+ Architect/Engineer: Phone(. '3 0'<~ ) (/ S '1J - 6 OJ.- s- r;; - Phone~3Gu ) C./ C) 9- ~ b q - <) h ~ NJ -e t -{> J Zip: q S 3 G tJ.. Phone: r 5y':>t-<M:<:> Contractor A , f Jf\ e 1- \ ye. 5 p., feW. State License #: Exp: Phonct36&l) "1 '5 )5<'; Y7 Address: 1~ ') L::- (:'q lY~(lV{ V\ f' Oiki.1 r;~-City: 6uyL\N8+-:Jf\. \'v.r' q&is? Zip: PROJECT ADDRESS: ~a5 su...:~e B i:: 8....."" ZONING: LEGAL DESCRIPTION: Lot: CLALLAM COUNTY PARCEL NUMBER: Block: Subdivision: Credit Card Holder Name: Billing Address: Credit CardType VISA TYPE OF WORK: o Residential 0 New Constr. 0 Re-roof o Multi-family 0 Addition 0 Move o Commercial 0 Remodel 0 Demolition o Repair 0 Sign BRIEF DESCRIPTION OF THE PROJECT: 5ysic'tV\.. COMMERCIAL/RESIDENTIAL: Occupancy Group: Occupant Load: No. of Stories: Lot Size: Existing Sq. Ft. & Proposed Sq. Ft. Existing lot coverage _ % & Proposed lot coverage _% = Total lot coverage City: Exp. Date: MC # o Stove o Garage o Deck o Other l..t Dad. ~ SIZEN ALUATION: SF. @ $ /SF. = $ SF. @ $ /SF. = $ SF. @ $ /SF. = $ TOT~L VALU,\-TION $ J~~OO Dv..c..t I.U, tlA ~. I ~ Su.c __ _'0 L--1. I Construction Type: APPROVALS: PLAN: BLDG: DPWU: FIRE: OTHER:_ PLANNING USE ONLY: ESA/Wetland(s): 0 Yes 0 No SEPA Checklist required? 0 Yes 0 No Other: BUILDING PERMIT APPLICATION SUBMITTAL: The Building Division can provide you with information on the application and plan submittal requirements if you have questions. VALUATION OF CONSTRUCTION: In all cases, a valuation amount must be entered by the applicant. This figure will be reviewed and may be revised by the Building Division to comply with current fee schedules. Contact the Permit Coordinator at 417 -4815 for assistance. PLAN CHECK FEE: IF a plan check fee is due it must be submitted at the time the building permit application and construction plans are submitted. All other permit fees are due at the time of permit issuance. EXPIRATION OF PLAN REVIEW: Ifno permit is issued within 180 days ofthe date of application, the application will expire. The Building Official can extend the time for action by the applicant up to 180 days upon written request by the applicant (see Section 107.4 of the Uniform Building Code, current edition). No application can be extended more than once. I hereby certify that I have read and examined this application and know the same to be true and correct. I am authorized to apply for this permit and understand that it is my responsibility to determine what permits are required ,not the City's, and that I must obtain such permits prior to work. T:\FORMS\APPS\Buildingpermit.wpd Applicant: -cJ.., dO -/0 ,,:)-2- Date: <:J -5.. -2. S- - 0 <; 03/2~/2004 12:43 3507555045 ALPINE FIR~/~c~~UNv f7LPlnE ARE AND SAFElY SYSTEMS. INC. Fax ~.gor Too~nY;~h~ ~~ Fax: __D.L{I"l.L{711 Phone: - ;'l-l! If'~1 0' oS &>0 e. Y\.de>.... CC: o Urgent ~_ Review 0 P..... Comment 0 Please Reply o Please Rec,cle FILE '" 735 E. Fairhaven · P.O. Box 265 . Burlington, Washington 98233 · (360) 755-5444 f>.fl,.,f.D tl~ - ~'-t 03/23/2004 12:43 3507555045 ALP INt. r H<t:.1 t"(t:.::Jr-UI~l) The Wet Chemical Fire Suppression System AANGI;GUARD. 2-1 Cylinders Cylinders Range Guard systems have available ~ different cylinder slzes~ RG-l.25G (1.25 gallon (4.7L)), RG- 2.50 (2.5 gallons (9.5Lll. RG-4GT (4 gallon tall (15 L)). RG-4GS (4 gallon short (l5Ll] and RO-60 16 gallon (22.7LlJ. Each cylinder Is pressurtzed With nitrogen or air to 175 pslg (1205 kPa), at 70ey (2)eC). . Note: It Is recommended that cylinders be stored upright. RG-4GT 4 GallonTal1 (15L) RG-6G 6 Gallon (22.7L) ~ RG-4GS 4 Gallon Short (15L) RG-2.5G 2.5 Gallon (9.5L) RG-1.25G 1.25 Gallon (4.7L) Figure 2-1. CyUDder Table ~1. CyUndt:r Spedfl~tiOD. .../ .-." Cylinder SItl! Part .No. Charged HeIght to Center Weight ": Diameter of Discharge Port Lbs Inches Inches Overall Height Inches . .o,,&rall Helg~t With. Overall Height Meeh, EI~cor Tandem With Pressure Op 'Control Head ., Control Head . Inch.. Inches Btml 4().3,14 lJ3.5crrl 40-7/9 (104 OIl 1&a14 ~ 22'W. , B1.3an 2().3/B 1.7an 3&-lQ 7a1l :lXi9 (93cm) 28.5 14 1&39 _~ 21 m3XX2 B121XXll B12m)4 B121JXli U.L/. Ex 2456 2.' Manual Part No. 9127100 (9/97) Badger Fire Protection 03/23/2004 12:43 351375551345 ALt-' 1 Nt:. r- l.r::::I:../ r>..C.::H WI'U..'; A"....~:~..,~ IUIInU& .......... The Wet Chemical Fire Suppression System 2..3 Brackets a. c e. AG-1.25G, 2.6G, 4GS & 4GT Mounting Bracket ... ".1 Figure 2-5. Mounting Brackets Table 2-2. MouatmgBn.cketDUileiU:f.ons .. .1 ~ :.. J " , Part Cylinder Dimension Dlmenslol Dimension Distance Betwee!n . Distlince BetWeen No. Size A B C Vertical Hol.s Horizontal Hbles . .",., ... ... 9197430 1.25 Gallon .3' 9-3/8' 1-3111' 3-1/4' 1.518 (4.71) (7.6 em) (23.8 em) (3.5 em) (8 em) (4.1 em) 9197263 2-112 Galon 4.5' 12" . 2-112' '3-1f2"~.c - (9.SL) (11.4 em) . (30.5 em) (6.4 em) (8.9 em - 12 em) 9197414 4 Gallon-L 4.5' 20.5' 2.112' 3-112" - (15L) (1 Hem) (52. 1 em) (6.4 CI1l) (S.gem) 9197416 4Galloo-S 4-1/2" 1 10112' 2' 3-1,z - (15L) (11.4 em) (29 em) (Sem) .. , (8.9 em) 9196779 6 Gallon FigureH Figure2.Ej figure 2.6 - - (22.7L) . U.L.I. Ex 2458 2.3 Manual Part No. 9127100 (9/91) Badger Fire Proteclion 03/23/2004 12:43 3507555045 ALt-' 1 Nt:.. i J. ~c. i r"\.t:,..::W WI 'tv The Wet Chemical Fire Suppression System UtfGIiGVMD.'. . , . ., ' . . . .' '... . _~. j' 'l., III . .. . ". .-".. 2-5 Mechanical Control Head P/N'sB486607, 8899063, arid 8899176 The mechanical control head.1.s used on systems e~uipped with fUSible. link detectors. When a fusible link detector operates. the release of tension in the fusible. link cable allows the control head to actuate. ^ sprfng-Ioaded plungerdepress~s the check stem In the PIN B486807 does not have an1lcroswtt~h_ PIN cylinder val~.dlscl!~gtngthe:co~~ente ()f the cyl1nder.B8990631S eqU1pped~th one Form "C" microswttch. The~~ntrol head t!i~o'releases teii~lord~ a cable to an _ PIN 8899176 Is e~uippedW1th two Form "e" ' optional t~dem control head or gas shutofTvalve. nueroswltches. The mlcro$W1tch contacts In 'both causing operation of these deviceS. The control head is corttl'ol heads transfer when the control head operates. e~u1pped With a local manual release handle integral With the control head cover plate. To manually operate the system locally. pull the ring pin out and rotate the handle clockwise. A mechanical. remote manual release may also be used with the mechanlcalcontrol head. TO FUSIBLE LINKS ONLY TO REMOTE. MAN,UAL PULL' . ONLY'- . MANUAL RELEASE LEVER BACK PLATE OPENING ALTERNATE (LOW P~9~.I,LE) TO FUSIBLE LINKS ONLY " . TO'TANDEM CONTROL HEAD OR FUEL SHUTOFF VALVE ONLY ACTUATING CAM (SHOWN IN SET POSITION) 'L " {, ..' '..:. , .~ . ,.. Figure 2..7".Mechanlc::aI:ControiHead,PJIIIS486.6D7 (rfo~lcro~itch) (Shown !11th cover i~ov~~1) . -:. -'.. . . ,. _.' .. . -. . '" . . : '.~ ":' '. . . . . ..L U,L.1. Ex 24SB 2.5 Manual Part No. 9127100 (9/97) Badger Fire Protection 03/23/2004 12:43 350i~~~1:148 f-1Lr .l1'lC ! .L"L...I I ''--'I '-'I'...... ... The Wet ChernlealFlre:Suppressiorl Sytlltem 'UNGI';'GUAII) , -. ".,..',.. ',: . ", . '..' .', t. ~, 2-13 Surface Mounted Remote Manual Controls (bleeb:8.nt61i1 .nd ':elee tric control heads) ." .,.; Mechanical, 'Remote Manual Release, PIN 8875572 The mecl1anlcal. remote manual release is provtded as a means of manuallyactuaUng the system from a remote location. The mechanical. remdte mallual : release is used only wl.th the Mechanical or Electric Control Heads an~canno~ ~'J,1Sed w1~ the A+ Control ,. Box, The,meehanlcal, remote .~ualr~lease Is , llttached!p the p~ary CPIltr()l}:1ead: V4th III 6ft cable. To actuate the system atthe'J!l~~calo.remote manual' release, pull out the ring pin and pull hard on the handle. Each manual release is supplied With a separate nameplate. This niuneplate must be attached to the mounting surface 1" above or below the pull station. ... NOTE: This RAMote Manual Release is only for use with the Mechanical Control Heads, part num- bel'l 8406607, B899063, BB99'76 end Elec- - trle Control Head part number 9899175. This Remote Manual Release.anD.Q1 be used with the A+ Control Box_ Refer to the installation section of this manual fOT installitlon limitations. Figure 2.' 9. Manual Pull Station, PIN 9875512 U.L.t. Ex 2458 2-13 Manual Part No. 9127100 (9/97) Badger FlreProtectlon 03/23/2004 12:43 3507555045 AAIfGI. .CIIAAD'.... . - - - I _ " ':' ~ -:' . ~\ - -..' . - - ;-, . ."' - . 2-16 COl11erPulley/Vent Plug, ALl-' iN!:. r .lr<:!:.1 r<:c.:=>rUI'iJ..l I HUL.. UU The Wet Chemical Fire Suppression System _ . INTERNAL CORNER ,PULLEY BEARING +- STAINLESS STEEL CABLE Figure 2-25. Corner Pulley 8844648 Corner PuIL!ly and D,etection Cufe The Comer Pulley can tie used in both low and h1gh temperature envtrbnme'nts. The 'puUey contains steel ball beartngi:1:tlil~',the body is cast aluminum. ~". '--. .,." .. ':I,' ,ifl'6" (.2cn11'iilameter ~"tatnless steel '1x7 strand cable Is usedfOr thedeteetJon llne. It Is Installed in 1/2" (1.3 cm) EMT. r 1-1/811 (2.9 em) 1 ,..,.-- .......... .~. . : C Vent Plug A Vent Plug is used in the discharge piping near a Range Guard cylinder to prevent pressure bU1ld.'Up In the discharge pipe system. caused by Mat. from rupturing the foU seals on each nozzle. The Vent Plug is to be installed tn the discharge piping so that It faces the ceiling of the"1Vall. CAU- TION: NEVER INSTALL IT PACING DOWN OR AT THE FLOOR. %" (1.3 em) . ~ NPT Figure 2-26. Vent Plug 9196984 U.L..J. Ex 2458 2.16 Manual Part No. 9127100 (9/97) BadgBr FIre Protection 03/23/2004 12:43 3507555045 The Wet Chemical Fire Suppression System 3-SDeep'Vat Fryer. and Griddle SINGLE V.AT DEEP FAT PRl'ER WITH DRIP BOARDS One F nozzle or Plenum nozzle will protect one Stngle Vat Deep Fat Fryer with a maxtmum hazard. area of 18" x 18" (46 em x 46 em) and an appliance area 18" x 23" (46 em x 58 em) for fryers W1th a drip board. The nozzle is located at an angle of 45 degrees or more from the horizontal. It shall not be more than 45" (114 em) nor less than 27" (69 em) from the top of the appliance and aimed at the midpoint of the hazard area. The nozzle ean be outsld.c the perbneter of the appliance. (Hazard Area 18" x IB" (46 em x 46 em) - See Ftgure 3-7) .. 122llll1) - ...., 'Ill!>d~ ..1"I'..r........... .. AlII. " -" Figure 34. Griddle -"Flat Cooking Surface SPLIT VAT DEEP FAT Jl'~1"ER One F nozzle or Plenum dozzle will p~oteet aSp1it Vat Deep Fat Fryer With a spUt v;a,thaz~:\.1~Te~max1" mum of 14" x 15" (36 em" 38 cl'b;) WJ,tiu#t'f:Clnp board and 14" x 21" (36 eID'x'SS c:m}'W1tha c&ipboard. The nozzle 1s located at an angle or 4$degree'S or mote from the hortzontal. It shallJiCit bC<l,more than 45" (114 em) nor less than2T r69emffro~tbe top of the appliance and iimed'at the mJdpotnt orthehazard" area. 1'he nozzle can be outsid!!! the perfni't~ bf the appl1ance. (Hazard Area 14" x IS" (36 e11i x ~8 em) - See figure 3-9) U.I..1. Ex 2408 ?4Lt'""' l.I'4t:. r .l~c..1 r-..c..::>r Ul'U.) .A._ ..... . '... .... .M..... IUVW....GURlfM. .. -'. -~.- .- AN F NOZZJ..E MAY BE LOCATED ANYWHERE wmtlN THE GRID DIAGONAL FROM AIM POINT DRIP BOARD 1r (" crrir MAX. Figure 3-7. Single Vat Deep Fat Fryer GRIDDLE ~ FLATCOOKlNG SURFACE One ADP nozzle Wtll pr.otect one griclclle (wtth or Without ra.t.sed ribs) With a max1mum hazard. area of 30" x 42" C7S cm x 107 em). The Dozzle I. located at uy polDt OD the perimeter or the appllaaee and atmed at a potnt 3" (7.6 em) from the m1dpotnt of the hazard area. It shall not be more than 48" (122 em) nor less than 13" (33 em) ab~ the edge of the appli- ance perimeter. PodtiolWl&.,the Dozzle directly over the appUUlce b...crt".eceptable. (Seefigilre 5-8.) -'"'. . AN F OR PLEf.lUM NOZZLE MAY BE LOCATED ANYWHERE WITHIN THE GRID ~i'::':;~:' .. ;, MAX DIAGONAL FROM AIM POINT 45" (11~ em) MAX" AIM POINT: MIDPOINT OF HAZARD CENTERED Olil DMDER ~ 21" (114 em) INTERIOR OVERALL ~ ~ 3.5 Figure 3-9. Split Vat Deep Fat Fryer Manual Part No. 9127100 (9/97) Badger Fire Protection 03/23/2004 12:43 3507555E14:J t-.1Lr l.l''iC. r J..KC.J r,"c.~1 WI.U..... -RANCE GUARD. The Wet Chemical Fire Suppre$siOn Sy~em 3-6 Single Vat Deep Fat Fryer (with clripboards less than 1" '(2.5 em)) OneF Noule or Plenum Nozzle will protect a deep fat fryer with a maximum hazard area of 24" (61 em) x 24" (61 em) and an al'plIance area of 24" (61 em) x 2.5" (63.5 em) for fryers With a clr1pboard. The nozzle shall be located at any point on or within the pertmeter of the hazard area. aimed at the midpoint of the hazard. It shall not be more than 46" (117 em) nor -less than 27.5"(70 em) above the edge of the appl1anct top. (See F1gurellJ 3-10 & 3-11). t' t, 1'\ I 1 , I I "I I I ,\ '/ I , 1"",1,/ I . .,'.- T ""9"" -. II Hozzle Ca'" b& pj~ced' I anywhere within the shaded :~rea _. 24' 25' (61 em) (63.5 em) MAX Intenor I /m> ~.. ':~ ~ the nozzle anylllh.,.. tMthln th. ,.rtm..r of the H.urd.Anta. Aimed -* 111. mldpOlM of the hUllnt a,.., 46" , "7cmL Max : ,~ I ) ~ Figure 3-10. Nozzles ,tor Deep Fat Fryer ....,,1 ;"./, ~ ,..t, ' Top of Appliance Figure 3~ 11, Single Vat Deep Fat Fryer U.L.1. EJc: 2458 3-6 Manual Part No. 9127100 (9/97) Badger Fire Protection 03/23/2004 12:43 3507555045 AAt<<iE..GUUD. ALt-' 1N!=. r 11"(1:../ I"(I:..::>rul~1J I ,....,.......1.- The Wet Chemical Fire Suppresslo~System 3.8 Module Protection (Multiple Nozzles) For appliances that exceed single nozzle coverage. multiple notzles can be used to protect that appliance by modular1zing (diViding up into smaller sections} the larger appliance's hazard area. Exception: for deep fat fryers the maximum pro- tected area for a stngle vat is 6 ft.2 (0.6m2) (864 in.~) [5574 cm2). For a deep fat fryer that exceeds single nozzle coverage. multiple F nozzles or Plenum nozzles can be used by dividing the hazard area into smaller modules that meet the 11m1tatlou of a single nozzle. Single Vat Deep I"I:lt Fryer (with d.rlpboards !.!:&s than. J" (2.tS em). The maximum appliancc area of a deep fat 24- fryer that a F nozzle or Plenum nozzle can 832i" 161 em) protect ls 25" x 24" (63.5 em x 61 em) or 600 (Inierl:') MAX In' 13871 em') foil surlac. pl.s drtpboardl. r I For coolc1ng oU area only (Without a. drlpboard). the max1mum protected area ls 24" x 24" (61 cmx 61 em) or 576m2 (3716 cm2). The longest slde of the hazard module:. cannot be longer than 25" (63.5 em). Therefore. each module that the larger hazard area 1s divided into. must not exceed 24" x 24" (62 em x 61 em) [576 in2 (3716 cm2)) and appliance area of 24" x 25" [600 in" (3871 cm2JJ if a drip board . 15 included. A single F nozzle or Plenum nozzle 1s then used to protect each of these smaller modules. Each nozzle Ls then.poBltloned using the l1m1tatlons given for S:1nglcnozzle coverage. Then()zzle must be located on or wtthlnthe peruneter of the module that tt 1s protect- 1ng;" It must be located no more than 46~ (117 em). but no less than 27.5" (70 em) from the top of the appll. ance. abned'at the midpoint of the modulc it ls pro- tecting. (See Exarnple 3-14 and 3-15). Imaginary Line Dividing Modules . NOTE: For Tilting Skllletsnsrazlfl9 Pans: The protectl~n of tilting s~ets!brazing pans is allowed provided the protection Ilmttatfons are based on the coveragellmitaU0n.5,for deep fat ~rs as outlined In this manual. Specia:latten&.oii~shoUIdhe noted for 10cat1rtg th-.: nozzle(s} tttwardthe froill of the appliance to m1n1m1ie the potentiu) for thesk11l.et cover to interfere with the nozzle discharge, ' U.L.1. E.x 2458 l.AIqtll 1M nozzt- anywhe" WIthin the pertlMlilr of Ih, HazanI.AI'I..AImed at Ih, midpoint of Ih, hilZllni ...... 46- 117 an) Max 27.5. 70 em) MIn Top of Appliance . DRIPBPARD 18. j 1"- (.e at1) (9~em) ... Figure'3-14.ModularProtection, Single Vat Deep Fat Fryer (less than 1" dripboard) Nozzle B \ I, , \ 1, \ . I, \ I , I ~ , "I ,. I", I "I',. I ,\ I,. , ,\ /,. , "I,,. , . I . II Module A lTt Module B Nozzle can be placed anywhere within the shaded area directly over the module, that Is being protected by the nozzle. I I I I I I I II 3-8 Figure 3-15. Nozzles for Deep Fat Fryer Manual Part No. 9127100 (9197) Badger Fire Protection 03/23/2004 12:43 3507555045 The Wet Chemic;:al Fire Suppression System ALr-' 1 Nt. r 1 rzt.1 rzt.~r-'UI'll) rH\:lc. .It::J AANCECIIAAD. 3-13 Range RANGE One 'R' nozzle will protect one four burner range with a maxlmum hazard area of 28" x 2B" (71 em x 71 em). The nozzlE: 1s to be located directly over the m1dpoint of the hazard area and anywhere Within the area of a circle generated by a 9" (23 em) radius about the midpoint The nozzle shall not be more than 42" 007 em) nor less than 20" (51 em) from the midpotnt of the hazard area, aimed at the midpOint. (See figure 3-25) NOTE: SHAPE OF BURNER. NOT IMPORTANT i." ,.. anI DIA. -42" (1DJ cm)1IAX. (F.... 'hip fit RII"". I"""'.., " 'R' NOZZLE MA't 9~ LOCATED ANYWHERE wrTNlN THE StQl)!F;D AAI!A. 1,",SI -I ~ BURNER CENTERUNE TO CENTeRUNE 14" (31 em) MAX. 8UMI!R CENTERLINE TO CENTERLINE Figure 3.25. Four Burner Range SINGLE BURNER RANGE Spec1al care is to be taken when aiming the 'R' nozzle over a single burner range. The a1m1ng paint 1s to be located 7" (18 em) from the center ofllie burner. The nozzle placement shall fall within a cylindrical area generatecl by a 9" (23 em) radius about the a1m1ng point. The nozzle must be placed no more than 42" (107 em) nor less than 20" (51 em) above the hazard area. (See fil!Ure 3-27) U.L.1. Ex 2458 Figure 3-26. Two Burner Aim Point Center of Hazard 18" (46 em) DIA. - 42" (107) MAX. A 'R' NOZZLE MAY BE LOCATED ANYWHERE WITHIN THE SHADED AREA. 7" (18 em) FROM BURNER CENTERLINE TO AIM POINT CENTERLINE Figure 3-27. Single Burner Range 3.13 Manual Part No. 9127100 (9197) Badger Fire Profoction 03/23/2004 12:43 3507555045 AL~lN~ rl~~!~~~~UNV ,i-i\:lt:. 1.1. UNCI CIIAftIl The Wet Chemical Fire Suppression System 3-14 Designing for Plenum Protection A single ADP nozzle will protect a s1ngle filter or 'V' by one ADP nozzle. The nozzle shall be loeatc:d at one end f11ter bank plenum with the folloWing maximum olthe plenum, Longer plenums maybe stmUarlyprotected dimensions: with a slngleADP nozzle bemgusc:d for each 10 ft. (3,0 m) of plenum length and each 4 ft. (1.2 m) of plc:num width. ADP nozzles may be used in combinations (see Figure 3-28). Multiples maybe installed in pairs at the midpoint oCthe plenum with their discharges directed at the ends of the plenum or installed at each end of the plenum With the discharges directed at the midpoint. Installation of a pair of nozzles back to back on a tee In any combination is permlsible. ADP nozzles must be centrally located In the plenum With thetr discharge directed along the length of the plenum and located in relation to the filttts as shown in figure 3-28. Plenum Length 10 Feet (3.0 m,) Plenum Width 4 Feet (1.2 m) When no ruters are present. the nozzle protecting the plenum is used to discharge The wet chemical on the underside of thc hood. In thiS case, the hood may not exceed a length of 10 ft. (3.0 m). The hood sballnot e."Cceed a Width of 4 ft. (1.2 m). A plenum With eUher a single ffiter bank or "V" fUter bankandalengthoflOft. (3.0m)orless maybe protected 4 FT. (1.2 M) P,-ENUM WIDTH I NOZZLE LOCATED AT EITHER END I~'~ OF PLENUM LENGTH AIMED DOWN , LENGTH OF PLENUM ADP NOZZLE 1 FLOW NUMBER ADP NOZZLES ACCEPTABLE NOZZLE POSITIONS FOR MULTIPLE NOZZLES .. 1/3 wi. HiI -*- I+- W -.f SINGLE BANK FILTER COVERAGE f1gute 8-28. Ple~um ProtectiOll U,L.1. Ex 2458 3-14 Manual Part No. 91271 00 (9/97) Badger Fire Protection 03/23/2004 12:43 3507555045 ALPIN~ rl~~/~~~~UNU ~,c;\.:lt:. .l.L The Wet Chemical Fire Suppression System AANCE.GIIAAD. 3-15 Designing for Duct Protection ADP Nozzle Two ADP nozzles shall be used 1n ducts with a perlmeter up to 75 inches (190.5 em) lor 23.8 (60.5 em) inches max:tmum diameter). The ratio of the longest to shortest perimeter sides shall not exceed 3 to 1, One of these nozzles is pointed into the duet and the other 15 pointed 111to the plenum. The tip of the upper nozzle. of the pair of nozzles required for each duct. shall be pOSitiOned tn the center of the duct opening and above the plane of the hood.duet opening between 1" (2.5 em) and 24" (61 em). The duct length is unlimited. (See figure 3-29) DUCT When the duct perimeter exceeds 75" 090.5 em). divide the duct area with imaginary walls so that the smaller ducts created have a perimeter of 75" r 190.5 em) or less, lncludlng the lengthls) of the imaginary wallis). Place a pair of ADP nozzles 1n the center of eaeh of the imaginary ducts With one nozzle pointed into the duct and the other nozzle pointed in the opposite direCtion. (See figure 3-30) NOTE: HOOD WHEN A DAMPER IS PRESENT ATTHE HOOD DUCT OPENINGTHE DUCT NOZZLES ARETO BE LOCATED ABOVE THE DAMPER AND SHOULD NOT INTERFEREWITHTHE OPERA- TION OFTHE DAMPER. Note: All Range Guard syatem. are 1lIIted by UL for uac with the eUaU8t fan either on or off when the s)'IItem is dJaehu,ed. f 24" MAX. 1" MIN.~ Figure 3-29. Duet Nozzle Placement 2) SUBDMDED DUCT INTO TWO IMA.GINARY SMALLER DUCTS. THE SMALLER DUCTS PERIMETER ARE LESS THAN 75" (1S10 em) AND REQUIRE THE USE OF A. PA.IR OF ADP NOZZLES IN EACH. I I I I I I I I I I I I..........- 15" ---W PERIMETER=20" (51 em) 1""'-- (38 em)"'l + 15" (38 em) + 20" (51 em) + 15" (38 em) PERIMETER = 70" (178 em) PER IMAGINARY SMALLER DUCT EDIIlpie of. Duet that Exceed 75" (190 em) Perimeter 1) PERIMETER TOO LARGE FOR ONE PAIR OF ADP NOZZLES. r 20" (51 em PERIMETER · 20" (51 em) + 30" (76 em) + 20" (51 em) + 30" (76 em) PERIMETER. 100" (254 em) L 14 3D" (76 em) ~I ngure 3-80. U.L.1. Ex 2458 @ 3.15 ONE PAIR OF ADP NOZZLES PER DUCT @ Manual Part No. 9127100 (9/97) Badger Fire Protection 03/23/2004 12:43 3507555045 RANCE QIAAD ALPINE FIRE/RE~~UND r'Al:lt:. .1.:1 The Wet Chemical Fire Suppression System 3-16 Designing for Protection of Small Ducts Ducts 25 feet (7.6 m) or less in length and with a pertmeter of 48" (122 em) or less (or lSA1/4" (39 em) diameter) may be protected with one ADP nozzle pOUlted up into the duct. The ttp of the nozzle shall be positioned In the center of the duct opening and above the plane of the hood-duct opening between I" to 24" (2.5 to 61 em). When using this type of duet protection it is neces- sary to reduce the maximum plenum protection that a single ADP nozzle can provide. The max1mum plenum SINGLE FILTER BANK ~Nob I'. ADP v NOZZLE ~ ~ ~ protection USing a single ADP nozzle when USing a single ADP for the duct is 6 feet in length for Singh: IDter bank plenums and 3 feet 1n length for "V' filter bank plenums. The maximum width remains 4 feet. Additionally. a single F nozzle can be used for plenum protection in thiS application to proVide a maximum of 10 feet in length and 4 feet in width coverage for s1ngIe or 'V. lliter banks. The single F nozzle accounts for two flow numbers. (See figure 3. 31) "V" FILTER BANK EJ ~ ,.. LOCATION OF NOZZLE WITHIN PLENUM PLENUM OR ADP NOZZLE CENTEREO IN PLENUM ("~~MUM FILTER SINGLE FILTER BANK PLENUM OR ADp NOZZLE CENTERED IN Pl.I;NUM ~ ~MUM ~ 'V' FILTER BA.NK Figure 3-31. PlenUDl Protection When V.iDg Single ADP Nozzle on Small Duets U.U. Ex 2458 3.16 Manual Part No. 9127100 (9/97) Badger Fire Protection 03/23/2004 12:43 3507555045 ALPIN~ ~l~~!~~~~UNU t""""i-\\:lt:. .L4 The Wet Chemical Fire Suppression System AANCE-CU'AftD. 3-21 Nozzle Snn11nary Table 3-2. Nozzle Summary Perimeter Diameter Nozzle I Hazard Max. Max. Length Flow No. Duct 50" (165.1 em) 15.25" (39 em) Unlimited. AOP /1 q; ,I.." ~;::J!f!.;;'1I1~Ol'2'.~,C T' "-".l;" U' ~;:"'. .":1"" 'f,;l;".?;f'~.i<f~:"Q,'r~1 . ~;..~ ::~::;~~~~""f!\:tilJl ~ :NdJll~~I..: Length Width Nozzle J Hazard Max. Max. Filters Flow No. Plenum 10' (3.0 m) 4' (1.2 m) "V" Bank or Single AOP / 1 Hazard Size Nozzle Height Notes Nozzle/ Hazard Inches/em Inches/em Inches/em Flow Four-BumerRange 28 X 28 (71 )( 71) 201042(5210107) within 9 (23) rad. of mid point. R 11 ~,,~'!r;."'~;i'!k1A1:iP:~:~:'..(..,~" ~~..e1~:'=:1~~.~~J~!;i~l''='~~I.'':'t~''+;';'~''~~:'_.'''''-''')'_: :":'H 271045 (69t0114) 45"1090. F/2 . .~; II I.." ,: ' ',. 1:1.'., r:Th~~il~:':i~~~.~.~.f:,:/~\:j~;:;~:.:.,~:. .... '. ~ ~ .._.001 ..1111 ::r.'WIl\Wl~1 :~-~:.(~.....,~)..~,.l..,,\. . "'~_', ' 14x15(36x38) 27(69)t045(117) 45" to 90' FI2 g. . ~'jj."m!> " ~"~,.,,.."..,~. l'l'ijl~""-"'o,.,.. mw=['I..<~;~~f:jr:;t'J,~:'""",,; '~--""'":~~.JtI;.~~_iJ'~"'~':1~.~~,,' within 2 (5) 35 to 56 (89 to 142) of mid point. GRW /1 . .;., '. ,m't'Cs.iijpfir,i~iAt)f'i?f.;~~r ...\ ,;,dll;a, .'..1.':. .~..~. ,..~,_,."..\l', "'_. ._.;.l.;,.~..~..,~,..~".~r:;'I-.~ Closed Top Chain Broilers 2BX29 (71 x 74) See 3-12 See 3-12 ADP/1 ~iti1@~!~il~~tfl1liJnr~~~~~~~.~~]~:. Pumice Rock (Lava. Ceramic) Charbroiler 22 X 23 (56 x 58) 24(61) 1048(122) 45"1090.; . 2 Layers of rock FI2 ElectricCharbroiler(OpenGrtd) 24 X21 (Sh 53) 24(61) 1048(122) 450 to 90" GRW 11 ~~~BlmJI~m~~~~ta,lfi~~j~~~~fM~l'~Ji~!\; MesquileCharbroller(Chips. Wood, Logs) 30 X24 (76 x 61) 24 (61)1048(122) 45" to 900; 10 (25) Fuel depth OM I 3 Nozzle Nozzle Part Identification No. Flow No. 27.5 in (70 em) 1046 in (117cm) within perimeter F/2 ADP (Appllance-Duct.Plenum) 8120011 ili~M"~~Jljlti. GRW (Gas Radiant.Wok) . B120013 1 :1~~~~;~\,';IS_i~ig~~;.~P\T1r:r~5~',;1~~=Hf:~1i~~;,~':1tr) OM (Mesquite) B120015 . ....., , ~I. .' 3"\~" ",,,,'1\I~.,,.,".'.,,,~,_, U.L.I. Ex 2458 3-21 Manual Part No. 9127100 (9/97) Badger Fire Protection 03/23/2004 12:43 3507555045 AU-' lNt. r lKt.1 Kt:.::>r-UI'UJ r':"":'\;Ic. ..L~ lANCE GUMD. The Wet Chemical Fire Suppression Syste_m 3-22 Cylinder Sizing After finding how many nozzles of each type are required for a system. the sum of all the nozzle flow numbers is used to determ1ne the number and SiZe of the cylinders required. in accordance With the cyl1nder flow number limits glven below, Table 3-3. Cylinder Flow Number Limits Maximum Flow Numbers of Cylinders Cylinder Flow Number RG-1.25G(4.1 L) 4 Single Cylinder Only (Cannot Manifold) RG-4GT or RG~4GS (15 L)(Long or Short 1 Cylinder 2 Cylinder!; 3 Cylinders 4 Cylinders 12 24 Can Manifold · 36 Up to 4 Cylinders 48 .Only like cylinders can be manifolded (ie, four RG-4GS, two AG-6G.) The system can be actuated through various controls, in accordance With Table 3-4. To actua.te a single cylinder system. use either the Mechanical Or Electric Control Head or the A+ Control Box With pressure operated actuator. To actuate two or three cylinders. use either one or two Tandem Control Heads and a Mechanical or Electric Control Head or the A+ Control Box with 1-3 Pressure Operated Actuator(s). To actuate from 1 to 5 cylinders. the A+ Control Box with Pressure Operated Actuator(s) must be used. For applications requiring 5-10 cylinders the BMCS.l nitrogen releaslng system is recommended. Larger systems. 10.100 cylinders, the BMC5-7 nitrogen releastng system 1s the recommended means of cylinder actuation. For complete details of the BMCS-l and BMCS- 7 systems, refcr to each respective manuals, PIN B900002 and P/N B9000003. Table 3-4. Actuation Controls Meehanlcal or Electric Tandem A+ Control System Size Control Head Control Head Bolt BMCS-1 BMCS-7 , Cylinder .,r ,/ ,/*u 2 Cylinders "'- .,r ,/.... 3 CVlinders .,r.. ,/ ./..~. 4 Cylinders ,/*. '" ",..~ 5 Cylinders ,/.. .,r ",..- 5-'0 Cylinders .,ru ",n. 1 0+ Cylinders ,/U .r... ",.-- . Roquires both a mechanical or electric control head and tandem control head .. Requires a mechanical or electric control head and multiple tandem control heads ..-SMes series requires a mechnical or electric control head to actuate. U.L.1. Ex 2458 3.22 Manual Part No, 9127100 (9197) Badger Fire Protection 03/23/2004 12:43 35075'::l'::lf.:14~ HLr.l.l'iC ! ..1..'.'L..../I....I....--.l1 1..-'11"'-" 3M Fire Barrier Duct Wrap 15A Commercial Kitchen Grease Duct Fire Protection System Product Data and Installation Instructions 1fiT ~. ~~~; i ji1l VOItA'1tli' ~~61 ""U,",IIIo:l"lI."'l JI: NFPA 96 Compllnncll 1 E1ee tdlUOn CampUss with InlDrnmlone' Meche.loDI Code Com pUg. wllh SlePldard Machgnlcel Cada r.~ :1", ComDftal'lC:" A"I"(l,12132 ~~!~~!~~~q lL;q~ ":)DtJ t :.J~_J:_ll:.J'-t-.J c' Figure 8 3M Fire Barrier Duct Wrap 15A Commercial Kitchen Grease Duct Systems 1 or 2 Hour Shaft Alternative Zero Clearance to Combustibles Suggested Roof Vent . c .- ~ ,.--... E ~ . . E .; N L(') ....... -..- .. ~ c.o ~ ,; 1 . Duct 2. Roof Assembl 3. Roof Flashin 4. Vent Flashin 5. One La er 3M Fire Barrier Duct Wra 15A 6. Firestoppin System for Rated Roof Assemblies Onl System integrlly is limIted by quality of InstallatIon. Page '7 (J.,JI..t:.......JI ~UU"'1' Figure 4A 3M Fire Barrier Duct Wrap 15A Commercial Kitchen Grease Duct Systems 1 or 2 Hour Through Penetration Systems 4.1/2 inch (11,4 cm) Concrete Floor or Wall ~~-'"l\' =r (76 mm) 0, =r (76 mm) 1. Floor/Ceilinq or Wall Assembly 2. Duct 3A. One Layer 3M Fire Barrier Duct Wrap 15A 3B Bandina or Pinnin!:l 3C. PackinQ Material 3D. 3M Fire Barrier 1000 N/S, 1003 S/L or 2000+ Silicone Sealant For Wall Assembly Apply Sealant To Both Sides of Wall System Integrity Is limited by quality of installation. Page , 0 Omega Point Laboratories, Inc. Through Penetration Systems FS 560 F FS 562 W FS 578 F FS 579 W A\ ~ " ~~. ~j(~j(~~~4 lL;4~ ":'OtJ r ~kJ;JtJ'"t-' ,i :l '... '" , '" -3 ::r ~i ~ ~ ::. ~ it ~ ~ .- :;. to "= I g" :p ~ = !4 lit) o...z ::J<l: ~u.. ::i ei 0 ::;E:<l: II a~ ~~I~ III In I!'li ll" ] '1IIi~l! ~ ~~ !1 i~. ,!;I:i ~ !~E ~12q i~~~~ 1:i I:;j I~I' 11111 ~ ~~~ ~ tlJt ~ :i5: j:~:a ~ ~~~ :z: o ....... I- U W I- wO ~~ .......a.. t.....1- o.::U =:l=:l CJR IR OW ~I- I-~ p ~ '511 ~ 111; ~ t1l % ClIe: 2~ 13 .Qc t:a ~~ fi-a 8 Nil uDl ~ n .x II D\~ ~ ~ u ,U ,. d Ul!J till+' a:;; -8~ ~ i l.. &01'" <i:aI ~] 0..:'" d :lIlU g-" L x I II .x ClI >. d' .x- dl ~~ " ~ I iii .,_ l.. lOt .f1 fii ~t;~ ~ii: a.l.. :lIUl.2!;ClI '<!CJ~ 4-UlU5~ ~ 4-ClI~-" M~ o:fodl.. I I ,,~t>" CD MM .f1Ult>~~ ... xx ~ClIaii~ l..~:ji ~ ~ g,3!U~ 8~ g~ ~ g 0\ (I) u .. P) I M x E ~ 10 !g o..l<i d:I:lIl~ ~~w g . 10 ~lcCl) c.... 1...1>10 l!!i Il!: of- ;c 4:~"'): . W,zl T > L-~ ~ j::~U12 ~ ~~~~ .. C I (u ... ~ L- III <t U i l<i -l g;~~ ~il:Wa'lo.. ~7in!liJ lUr-r- ~~I.l!)<iJ ... ~:::aI'w I ~I~f~ j::o..ullrdi! o..~Ca'lL:l ~,~O\, UM(')!:l)< ~ 8 J: >- i ~ l- V) ::JZ <l:<l: ~u.. W Q Q l- V) ::>w <l:~ :I:<l: xl- WZ .... Zo:: W.... W<l: :3: 1->- WZ I:Q<I: .. ~ oz ,I <I: o .-t z <( u.. I- 0<: l=l V) W -.J ~ ~~ :I: <( I X wV) w ~ l- V) ::>w <[~ :1:<[ xl- WZ ...... Zo:: w...... W<t :3:. 1->- WZ 1:Q<t .. A oz ,I <t o .-t ~:Z (\J::E: z <( L.... l- V) =:l <l: :I: x , I o<:l=l W -.J I W I- ..... <(I wV) ::3: ~ ~ '- '"' <e: 01 ~bil~ u~~~ ~p~~ A en CZl"';.......(l.) _ f:-t CZl ........ 8~~ ~ ~~~8~ ~ ~ 01 h p CZl 0 u P-; w ~O>di:::~ a..UJUJUJ -IQ;;l.L1- <(l.Lj,i;e CI) ~ o f\ 00 .-< ~ :A on ~ '" ,., o I ..-< II J $ '3 d i ~ cr- ~ "" ~ Q '2 .. J 7- .;J r-.l '1. cJ. j {l 2 .j. \9 0 :r ~ ~ CZl f3 00 ..... tZl ~ i1' ~ o a- i .. I.D ,I v l=la.. w<l: 1-0<: i52~ ~ti .....=:l t.....l=l 0.::1- =:l~ CJ=:l I<( I (\jX W fJ~ 1-0<: ~~ wI- ~U .....=:l u...l=l ad;;:; =:l=:l 0<( II (\jX W E:l ga o o o o o I DATE:3-.;l.5-ai../' FIRE DEPARTMENT PLANNING DEPARTMENT PUBLIC WORKS/ENGINEERING DIVISION LIGHT DIVISION o ENERGY o ENGINEERING POLICE DEPARTMENT " ADMINISTRATION o CITY CLERK o RlSK MANAGEMENT I FROM: PUBLIC WORKSIBUlLDING DIVISION' RE: ADDRESS: d-,OS E 6-t- q S iA; -te.. R NAME/CONTACT: S ~ / v e.r ~ a PHONE: lfQ - bq'-;;~ PERMIT NUMBER: PROJECT DESCRlPTION :_}!~ ~ Du...G t- w ~ -\ "^- 1=.~ ..r e.. S v-..pf>'-ress \ 10 .'\ ~ ys + e W\.. ~ NEW CONSTRUCTION o ADDITION/ALTERNATION COMMENTS/CONDITIONS: ~REVIEW/RETURN o FILE PORT ANGELES FIRE DEPARTMENT HOOD/DUCT SUPPRESSION SYSTEM PLAN REVIEW Project Name: Sergio's Hacienda Address: 203 East 8th, Suite B HID Installer: Telephone: System Installer: Alpine Fire and Safety Systems Telephone: (360) 755-5444 Permit # 04-04 We have checked this plan and find that it conforms to the requirements of our ordinance. The following items must be noted: I) The exact location of the manual pull station for the system is not shown. The pull station must be in the path of exit travel and easily accessible. 2) A "K" class fire extinguisher must be provided along with the system. The extinguisher must be located in an easily accessible location, with the top no more than 5' off the floor. 3) The hood and duct fire extinguishing system must be connected to the fire alarm system. Activation of the suppression system must initiate a fire alarm at the F ACP. 4) A full witnessed acceptance test of the system will be required. This test will include a balloon test, as well as tests of the fuel/electrical shut-offs, the pull station and the fusible links. Reviewed By: ~<.QO~ \ 3.2 <\. . <Dl.f Date: ~ Building Department o Contractor o Fire Department 04/12/2004 07:54 3607555045 ALPINE FIRE/RESPOND PAGE 01 f7LP/nE ARE AND SAFElY SYSTEMS, INt. Fax ;)05 4.-'--, <S+f2-EE} E 8 ~. 9k~ To= '''-..\ \. tv\. From: Fax: ~ - L(rr(~ Pages: Phone: Date: to{... \')..-0<.( , Re: CC: o Urgent 0 For Review 0 PleIlSe Comment 0 ....... Reply o Please Reqde ~(/~ 'Ue '\4-~ \ ~ F$ ~ h;(LVlL\.}. ~ , .z ~\ocJ FilE - t- 0 It- ... 735 E. Fairhaven · P.O. Box 265 · Burlington, Washington 98233 · (360) 755-5444 o o c.) 04/12/2004 07:54 3507555045 ALPINE FIRE/RESPOND PAGE 02 6. Installation Techniques Method: To minimize waste, 3M Fire Barrier Duct 3M Fire Barrier Duct Wrap 15A system should be Wrap 15A material should be rolled out tautly before k:-. installed in accordance with the following installation measuring. General instructions for installing the 3M instructions. ~ Fire Barrier Duct Wrap 15A include a one-layer wrap construction applied directly to the duct. The 3M Fire Note on Clearance to Combustibles: .~ Barrier Duct Wrap 15A blanket is wrapped around the 3M Fire Barrier Duct Wrap 15A has been tested to perimeter of the duct and is cut to a length to overlap protect combustible constructions at zero clearance. itself not less than 3 in. (76 mm). The overlap made The zero clearance is measured from the outermost by adjacent blankets forms the "longitudinal" overlap. layer of the protective wrap to the combustible item. ~Iuminum foil tap-~ i~ useqJ9 sea!.!!.~.~'::9Qes of ,tb! The outermost layer is always in the overlap or collar blanKet and an,t ~~ in. the foil s~rim. section of the installation. This means that there l .......;:' ".~",...'_'_'~h'~'- needs to be a. minimum clearance of 3 in. (76 mm) .. There Bre three (3) approved installation ~ between the surface of the duct and the combustib e techniques for installing the 3M Fire Barrier Duct item. Wrap 15A (See Figures 1A-1D and Figures 2A-2D): Material and Equipment . 3M Fire Barrier Duct Wrap 15A blanket, 1-1/2 in. (38 mm) thick, 24 in. (60 em) or 48 in. (121 em) wide. 20 ft. (609 cm) standard length. The 48 in. (121 em) wide blanket helps to minimize waste. . Aluminum foil tape. . Minimum 3/4 in. (19 mm) wide filament tape. . Carbon steel or stainless steel banding material, minimum 1/2 in. (12,7 mm) wide. minimum 0.015 in, (0.38 mm) thick, with steel banding clips. . Hand banding tensioner, crimping tool, and banding cutter. . Minimum 12 gauge copper-coated steel insulation pins; galvanized steel speed clips. minimum 1-1/2 in. (38 mm) square or 1-1/2 in. (38 mm) dla. round. or equivalent sized insulated cup~head pins; capacitor discharge stud gun. . Access door hardware: four galvanized steel thread rods, 1/4 in. (6 mm) diameter by 4-1/2 in. to 5 in. long (114 mm to 127 mm) with 1/4 in. (6 mm) wing . nuts and 1/4 in. (6 mm) washers: 4 in. (102 mm) long steel hollow tubing to fit threaded rods. . Minimum 4.0 lb. (1,8 kg) density mineral wool or scrap pieces of 3M Fire Barrier Duct Wrap 15A blanket . 3M Fire Barrier 1000 NIS, 1003 SIL or 2000+ Silicone Sealant. Storage The 3M Fire Barrier Duct Wrap 15A and 3M Fire Barrier 1000 NIS, 1003 SIL and 2000+ Silicone Sealants must be stored in a dry warehouse environment. Pallets should not be stacked. Preparatory Work: 3M Fire Barrier Duct Wrap 15A is installed with common tools. such as knives, banders and capacitor discharge guns for applying insulation pins. In order to install the duct firestop system. the surfaces of all the openings and penetrating items need to be clean, dry, frost free and free of dust. 1. Telescoping 3 in. (76 mm) Overlap Wrap With the telescoping overlap wrap method, each blanket overlaps one adjacent blanket. and each blanket has one edge exposed and one edge covered by the next blanket as shown in Figure 1 A and 1 B. The visible edges of the perimeter overlaps all point in the same direction. 2. Checkerboard 3 In. (76 mm) Overlap Wrap With the 3 in. (76 mm) checkerboard overlap wrap method, blankets with both edges exposed alternate with blankets with covered edges. as shown in Figure 1 C. The visible edges of the perimeter overlaps alternate their directions and appear on every other blanket. 3. Butt Joint With Collar With the butt joint and collar method, adjacent blankets are butted tightly together and 6 in. (152 mm) wide collar of 3M Fire Barrier Duct Wrap is centered over the joint, overlapping each blanket by 3 in. (76 mm) minimum as shown in Figure 1 D. In all three overlap techniques the perimeter overlap can occur at any location on the duct. The blanket is mechanically attached to the duct by steel banding or by welded insulation pins and clips for all three installation methods listed above. For Banding Only (See Figures 1 A to 1 D) Filament tape can be used to temporarily hold the blanket in place until the banding is applied. The steel banding is applied around the duct 1-1/2 in, (38 mm) from each edge of the blanket, and maximum 10-1/2 in. (26,7 em) centers. The banding is placed around the material and tightened so as to sufficiently hold the 3M Fire Barrier Duct Wrap 15A in place against the duct. compressing the foil but not cutting the foil. Pag~ 3 04/09/2004 15:19 3507555045 ALPINE FIRE/RESPOND PAGE 01 RLPlnE FIRE AND SAFETY SYSlIMS, INC. Fax ~. ~Y^ To: ~D'r1- ~n ~ Pe.v ffil.,t' From: ~ {.we.. ~(1\j ~~ ~ Fa: 31pO.1.{1'l' ,-\7/1 - 'S" - Irl~IVlj C/lU'W" Phonec ( ROfjex- - Fa.-J...e. ~ ~ ~ ') Date: Re: ~).D Y'~l 0' S J~C..t e. ~~ cc: [J - 'f;; Fw R_ 3/~3 04 (J ....... CoInment 0 Please Repl7 o P..... Recycle ~ h~ FllX - 3/ ~ S ) 0 Lf 3. r-d.. F" Q ~ ~ 4/ Cl I 0 y .~. ~ ~'" "4~' '" f~....l'~ "\/ 3\~ - :c ck~& W(~ a-.vr ~ ~. ~ "j.*. ~. u..s..L~ ~ ~1t.u.Q ~ ()~ ~(;Q ..,(_~..l\.u1~~ ~c<U~s I ~. ~ vU3 ....uAP(J tJ... .t;L.. ~a.1L~ cvJ) ttV..O c..u-~ J P CA~ ~ ~(M.6 _ ~ ~~ e'.-. f) ..~ ~.~"'^-- [a-FAXED. ~ I ...... ~ft ./~~\ .~ 735 E. Fairhaven · P.O. Box 265 · Burlington, Washington 98233 . (360) 755.5444 04/09/2004 15:19 3507555045 ALPINE FIRE/RESPOND PAGE 02 3IVI Fire Barrier Duct Wrap 15A Commercial Kitchen Grease Duct Fire Protection System Product Data and Installation Instructions triT ~ ..' ; .o~.~ !8. Eo!; 11" e"- _'21ll1' NFPA 96 c.....,...... ID~~ EdlIlon CompIlO~ whh ''''8rt1811o''"' ~"'c.1 Cod8 CClmpII9B wtlh S'....lllllfd MecMnlClll Ccld9 04/09/2004 15:19 3607555045 ALPINE FIRE/RESPOND PAGE 03 Figure 8 3M Fire Barrier Duct Wrap '5A Commercial Kitchen Grease Duct Systems 1 or 2 Hour Shaft Alternative Zero Clearance to Combustibles Suggested Roof Vent c' 0 c: 0- ~ ~ 0 E E N Ll) ~ "'- :: c.o ~ " , . Duct 2. Roof Assembly 3. Roof Flashing 4. Vent Flashing 5. One Layer 3M Are Barrier Duct Wrap' SA 6. Firestopping System for Rated Root Assemblies Only System integrity is limited by quality of installation. Page 17 04/09/2004 15:19 3507555045 ALPINE FIRE/RESPOND PAGE 04 Figure 4A 3M Fire Barrier Duct Wrap 15A Commercial Kitchen Grease Duct Systems 1 or 2 Hour Through Penetration Systems 4..1/2 inch (11,4 em) Concrete Floor or Wall ~,:.,\, ~ (76 mm) ..'., " . . ><>;~ :', -. I. .. , o =r (76 mm) 1. F/oor/Ceilin or Wall Assembl 2. Duct 3A One La er 3M FIre Barrier Duct Wra 15A 38 Bandin or Pinnin 3C. Packin Material 3D. 3M FIre Barrier 1000 N/S, 1003 S/L or 2000+ Silicone Sealant For Wall Assembl Apply Sealant To Both Sides of Wall. System Inlegrity is limIted by quality of installation. Page 10 Omega Point Laboratories, Inc. Through Penetration Systems FS 560 F FS 562 W FS 578 F FS 579 W ,~ .:' 04/09/2004 15:19 3507555045 ALPINE FIRE/RESPOND PAGE 05 CD ,CD ,,;, :~ :~ ,~ 'N ~~,: 0- n ~ :r. ~ 3m I ~ iii ." I ,f I"'C [ C a-