Loading...
HomeMy WebLinkAbout1809 Melody Ln - BuildingPREPARED 10/18/07 9 30 17 INSPECTION TICKET PAGE 5 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 10/18/07 ADDRESS 1809 MELODY LN SUBDIV TENANT NBR HECKMAN CONDOMINIUM CONTRACTOR VISION BUILDERS INC PHONE (360) 452 1186 OWNER JAMES LEA HECKMAN PHONE (360) 452 6116 PARCEL 06 30 14 6 2 0440 0000 APPL NUMBER 06 00000099 RES NEW MULTI 5+ FAMILY REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS 07/30/2007 03 58 PM JLIERLY BL99 01 8/10/07 JLL BLDG FINAL 8/10/07 CA 08/09/2007 04 46 PM LPANGRLE CRAIG 461 3985 BLDG FINAL WANTS OCCUPANCY FOR TOP 2 UNITS 08/10/2007 04 21 PM JLIERLY craig called and said they would not be ready and canncelled the inspection/j11 BL99 02 8/13/07 JLL BLDG FINAL 8/13/07 DA 08/13/2007 08 30 AM LPANGRLE CRAIG 461 3985 BLDG FINAL 08/13/2007 05 00 PM JLIERLY HAND RAIL REQS A RETURN FRONT OF BUILDING /FIRE SEAL BASEMENT PENETRAITIONS /VENT DECKS /FINISH HAND RAILS INTERIOR/ EGRESS SURFACE REQD TO BE NON COMBUSTABLE /ENVELOPE SEAL REPORT /ATTACH GUARD RAIL TO DECK /JLL BL99 03 9/27/07 JLL BLDG FINAL TIME 01 00 9/27/07 AP 09/27/2007 08 12 AM LPANGRLE CRAIG 461 3985 BLDG FINAL 4 NON FINALED UNITS AFTERNOON 09/27/2007 04 47 PM JLIERLY BL99 04 10/12/07 JLL BLDG FINAL 10/12/07 DA October 12 2007 8 20 49 AM 1pangrle CHRIS 452 1186 BLDG FINAL October 12 2007 3 42 36 PM jlierly fire stop penetriations in storage area /facvp label on fire alarm door /human impact protection at elevator vent /ada parking/j11 BL99 05 10/18 07 BLDG FINAL f October 17 2007 3 12 32 PM 1pangrle CHRIS 452 1186 BLDG FINAL PLEASE CALL HIM 30 MINUTES BEFORE YOU ARRIVE COMMENTS AND NOTES PREPARED 10/12/07 10 09 26 INSPECTION TICKET PAGE 7 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 10/12/07 ADDRESS 1809 MELODY LN SUBDIV TENANT NBR HECKMAN CONDOMINIUM CONTRACTOR VISION BUILDERS INC PHONE (360) 452 1186 OWNER JAMES LEA HECKMAN PHONE (360) 452 6116 PARCEL 06 30 14 6 2 0440 0000 APPL NUMBER 06 00000099 RES NEW MULTI 5 FAMILY REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS 8/10/07 CA 08/09/2007 04 48 PM LPANGRLE CRAIG 461 3985 PLUMBING FINAL WANTS OCCUPANCY FOR TOP 2 UNITS 08/10/2007 04 21 PM JLIERLY Craig called and said they would not be ready and canncelled the inspection/j11 PL99 02 8/13/07 JLL PLUMBING FINAL 8/13/07 AP 08/13/2007 08 44 AM LPANGRLE CRAIG 461 3985 PLUMBING FINAL 08/13/2007 05 00 PM JLIERLY PL99 03 9/27/07 JLL PLUMBING FINAL TIME 01 00 9/27/07 AP 09/27/2007 08 15 AM LPANGRLE CRAIG 461 3985 PLUMBING FINAL 4 NON FINALED UNITS AFTERNOON 09/27/2007 04 47 PM JLIERLY PL99 04 10/12/07 i& L PLUMBING FINAL October 12 2007 8 22 14 AM 1pangrle CHRIS 452 1186 PLUMBING FINAL COMMENTS AND NOTES PREPARED 10/12/07 10 09 26 CITY OF PORT ANGELES ADDRESS 1809 MELODY LN SUBDIV TENANT NBR HECKMAN CONDOMINIUM CONTRACTOR VISION BUILDERS INC PHONE (360) 452 1186 OWNER JAMES LEA HECKMAN PHONE (360) 452 6116 PARCEL 06 30 14 6 2 0440 0000 APPL NUMBER 06 00000099 RES NEW MULTI 5+ FAMILY REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BL99 01 8/10/07 JLL 8/10/07 CA BL99 02 BL99 03 BL99 04 10/12/07 8/13/07 JLL 8/13/07 DA 9/27/07 JLL 9/27/07 AP ME6 02 5/29/07 PB 5/29/07 AP PERMIT ME 00 MECHANICAL PERMIT REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS ME1 01 4/20/07 JLL 4/20/07 AP ME6 01 4/20/07 JLL 4/20/07 AP INSPECTION TICKET INSPECTOR JAMES LIERLY 07/30/2007 03 58 PM JLIERLY BLDG FINAL 08/09/2007 04 46 PM LPANGRLE CRAIG 461 3985 BLDG FINAL WANTS OCCUPANCY FOR TOP 2 UNITS 08/10/2007 04 21 PM JLIERLY Craig called and said they would not be ready and canncelled the inspection/j11 BLDG FINAL 08/13/2007 08 30 AM LPANGRLE CRAIG 461 3985 BLDG FINAL 08/13/2007 05 00 PM JLIERLY HAND RAIL REQS A RETURN FRONT OF BUILDING /FIRE SEAL BASEMENT PENETRAITIONS /VENT DECKS /FINISH HAND RAILS INTERIOR/ EGRESS SURFACE REQD TO BE NON COMBUSTABLE /ENVELOPE SEAL REPORT /ATTACH GUARD RAIL TO DECK /JLL BLDG FINAL TIME 01 00 09/27/2007 08 12 AM LPANGRLE CRAIG 461 3985 BLDG FINAL 4 NON FINALED UNITS AFTERNOON 09/27/2007 04 47 PM JLIERLY BLDG FINAL October 12 2007 8 20 49 AM 1pangrle CHRIS 452 1186 BLDG FINAL MECHANICAL ROUGH IN 04/19/2007 03 46 PM PERMITS PAT 461 5278 CALL FIRST partial inspection top floor only 04/20/2007 04 20 PM JLIERLY MECHANICAL GAS LINE 04/20/2007 01 40 PM PERMITS PAT 461 5278 UNITS 3 4 5 6 partial inspection top floor only 04/20/2007 04 20 PM JLIERLY MECHANICAL GAS LINE 05/25/2007 09 41 AM LPANGRLE JOHN 461 0445 CALL FIRST LP GAS PIPE FOR FIRST AND SECOND FLOORS CONTINUED ONTO NEXT PAGE PAGE DATE v 5 10/12/07 Ocx/L— e „Le et PREPARED 10/12/07 10 09 26 INSPECTION TICKET PAGE 6 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 10/12/07 ADDRESS 1809 MELODY LN SUBDIV TENANT NBR HECKMAN CONDOMINIUM CONTRACTOR VISION BUILDERS INC PHONE (360) 452 1186 OWNER JAMES LEA HECKMAN PHONE (360) 452 6116 PARCEL 06 30 14 6 2 0440 0000 APPL NUMBER 06 00000099 RES NEW MULTI 5+ FAMILY REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS 05/29/2007 04 29 PM PBARTHOL ME99 01 8/10/07 JLL MECHANICAL FINAL 8/10/07 CA 08/09/2007 04 47 PM LPANGRLE CRAIG 461 3985 MECHANICAL FINAL WANTS OCCUPANCY FOR TOP 2 UNITS 08/10/2007 04 21 PM JLIERLY Craig called and said they would not be ready and canncelled the inspection/j11 ME99 02 8/13/07 JLL MECHANICAL FINAL 8/13/07 AP 08/13/2007 08 43 AM LPANGRLE CRAIG 461 3985 MECHANICAL FINAL 08/13/2007 05 00 PM JLIERLY ME99 03 9/27/07 JLL MECHANICAL FINAL TIME 01 00 9/27/07 AP 09/27/2007 08 14 AM LPANGRLE CRAIG 461 3985 MECHANICAL FINAL 4 NON FINALED UNITS AFTERNOON 09/27/2007 04 47 PM JLIERLY ME99 04 10/12/07 f�i L MECHANICAL FINAL J October 12 2007 8 21 29 AM 1pangrle CHRIS 452 1186 MECHANICAL FINAL PERMIT PL 00 PLUMBING PERMIT REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS PL1 01 7/31/06 JLL PLUMBING UNDER SLAB TIME 13 00 7/31/06 AP DEREK 452 1186 07/28/2006 09 59 AM DYASUMUR 07/31/2006 04 22 PM PBARTHOL PL2 01 4/16/07 JLL PLUMBING ROUGH IN TIME 01 00 4/16/07 AP 04/13/2007 01 31 PM PERMITS JOHN SHAY 461 0455 CALL 461 0455 SO JOHN CAN MEET YOU THERE FOR THE INSPECTION THIS IS A PARTIAL ROUGH IN 04/16/2007 03 36 PM JLIERLY PL2 02 5/08/07 JLL PLUMBING ROUGH IN 5/09/07 AP 05/07/2007 04 57 PM LPANGRLE PAT 461 5278 PLUMBING ROUGH IN 05/09/2007 08 58 AM JLIERLY PL2 03 5/29/07 PB PLUMBING ROUGH IN 5/29/07 AP 05/25/2007 09 38 AM LPANGRLE JOHN 461 0445 CALL FIRST ROUGH IN PLUMBING (FIRST FLOOR AND SECOND FLOOR) 05/29/2007 04 29 PM PBARTHOL PL99 01 8/10/07 JLL PLUMBING FINAL CONTINUED ONTO NEXT PAGE PREPARED 9/27/07 12 24 27 INSPECTION TICKET PAGE 5 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 9/27/07 ADDRESS 1809 MELODY LN SUBDIV TENANT NBR HECKMAN CONDOMINIUM CONTRACTOR VISION BUILDERS INC PHONE (360) 452 1186 OWNER JAMES LEA HECKMAN PHONE (360) 452 6116 PARCEL 06 30 14 6 2 0440 0000 APPL NUMBER 06 00000099 RES NEW MULTI 5 FAMILY REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS 07/30/2007 03 58 PM JLIERLY BL99 01 8/10/07 JLL BLDG FINAL 8/10/07 CA 08/09/2007 04 46 PM LPANGRLE CRAIG 461 3985 BLDG FINAL WANTS OCCUPANCY FOR TOP 2 UNITS 08/10/2007 04 21 PM JLIERLY craig called and said they would not be ready and canncelled the inspection /j11 BL99 02 8/13/07 JLL BLDG FINAL 8/13/07 DA 08/13/2007 08 30 AM LPANGRLE CRAIG 461 3985 BLDG FINAL 08/13/2007 05 00 PM JLIERLY HAND RAIL REQS A RETURN FRONT OF BUILDING /FIRE SEAL BASEMENT PENETRAITIONS /VENT DECKS /FINISH HAND RAILS INTERIOR/ EGRESS SURFACE REQD TO BE NON COMBUSTABLE /ENVELOPE SEAL REPORT /ATTACH GUARD RAIL TO DECK /JLL BL99 03 9/27/07 JJi BLDG FINAL TIME 01 00 09/27/2007 08 12 AM LPANGRLE CRAIG 461 3985 BLDG FINAL 4 NON FINALED UNITS AFTERNOON PERMIT ME 00 MECHANICAL PERMIT REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS CONTINUED ONTO NEXT PAGE ME1 01 4/20/07 JLL MECHANICAL ROUGH IN 4/20/07 AP 04/19/2007 03 46 PM PERMITS PAT 461 5278 CALL FIRST partial inspection top floor only 04/20/2007 04 20 PM JLIERLY ME6 01 4/20/07 JLL MECHANICAL GAS LINE 4/20/07 AP 04/20/2007 01 40 PM PERMITS PAT 461 5278 UNITS 3 4 5 6 partial inspection top floor only 04/20/2007 04 20 PM JLIERLY ME6 02 5/29/07 PB MECHANICAL GAS LINE 5/29/07 AP 05/25/2007 09 41 AM LPANGRLE JOHN 461 0445 CALL FIRST LP GAS PIPE FOR FIRST AND SECOND FLOORS 05/29/2007 04 29 PM PBARTHOL ME99 01 8/10/07 JLL MECHANICAL FINAL 8/10/07 CA 08/09/2007 04 47 PM LPANGRLE CRAIG 461 3985 MECHANICAL FINAL PREPARED 9/27/07 12 24 27 INSPECTION TICKET PAGE 6 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 9/27/07 ADDRESS 1809 MELODY LN SUBDIV TENANT NBR HECKMAN CONDOMINIUM CONTRACTOR VISION BUILDERS INC PHONE (360) 452 1186 OWNER JAMES LEA HECKMAN PHONE (360) 452 6116 PARCEL 06 30 14 6 2 0440 0000 APPL NUMBER 06 00000099 RES NEW MULTI 5+ FAMILY REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS ME99 02 8/13/07 JLL 8/13/07 AP ME99 03 9/27/07 PERMIT PL 00 PLUMBING PSIFMIT REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS WANTS OCCUPANCY FOR TOP 2 UNITS 08/10/2007 04 21 PM JLIERLY craig called and said they would not be ready and canncelled the inspection/j11 MECHANICAL FINAL 08/13/2007 08 43 AM LPANGRLE CRAIG 461 3985 MECHANICAL FINAL 08/13/2007 05 00 PM JLIERLY MECHANICAL FINAL TIME 01 00 09/27/2007 08 14 AM LPANGRLE CRAIG 461 3985 MECHANICAL FINAL 4 NON FINALED UNITS AFTERNOON PL1 01 7/31/06 JLL PLUMBING UNDER SLAB TIME 13 00 7/31/06 AP DEREK 452 1186 07/28/2006 09 59 AM DYASUMUR 07/31/2006 04 22 PM PBARTHOL PL2 01 4/16/07 JLL PLUMBING ROUGH IN TIME 01 00 4/16/07 AP 04/13/2007 01 31 PM PERMITS JOHN SHAY 461 0455 CALL 461 0455 SO JOHN CAN MEET YOU THERE FOR THE INSPECTION THIS IS A PARTIAL ROUGH IN 04/16/2007 03 36 PM JLIERLY PL2 02 5/08/07 JLL PLUMBING ROUGH IN 5/09/07 AP 05/07/2007 04 57 PM LPANGRLE PAT 461 5278 PLUMBING ROUGH IN 05/09/2007 08 58 AM JLIERLY PL2 03 5/29/07 PB PLUMBING ROUGH IN 5/29/07 AP 05/25/2007 09 38 AM LPANGRLE JOHN 461 0445 CALL FIRST ROUGH IN PLUMBING (FIRST FLOOR AND SECOND FLOOR) 05/29/2007 04 29 PM PBARTHOL PL99 01 8/10/07 JLL PLUMBING FINAL 8/10/07 CA 08/09/2007 04 48 PM LPANGRLE CRAIG 461 3985 PLUMBING FINAL WANTS OCCUPANCY FOR TOP 2 UNITS 08/10/2007 04 21 PM JLIERLY craig called and said they would not be ready and canncelled the inspection/j11 PL99 02 8/13/07 JLL PLUMBING FINAL 8/13/07 AP 08/13/2007 08 44 AM LPANGRLE CRAIG 461 3985 CONTINUED ONTO NEXT PAGE PREPARED 9/27/07 12 24 27 INSPECTION TICKET PAGE 7 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 9/27/07 ADDRESS 1809 MELODY LN SUBDIV TENANT NBR HECKMAN CONDOMINIUM CONTRACTOR VISION BUILDERS INC PHONE (360) 452 1186 OWNER JAMES LEA HECKMAN PHONE (360) 452 6116 PARCEL 06 30 14 6 2 0440 0000 APPL NUMBER 06 00000099 RES NEW MULTI 5+ FAMILY REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS PLUMBING FINAL 08/13/2007 05 00 PM JLIERLY PL99 03 9/27/07 JLL PLUMBING FINAL TIME 01 00 09/27/2007 08 15 AM LPANGRLE CRAIG 461 3985 PLUMBING FINAL 4 NON FINALED UNITS II AFTERNOON COMMENTS AND NOTES Issue Date Expiration Date Parcel Number Property Address Subdivision Name Legal Description Property Zoning Owner Contractor Approved CITY OF PORT ANGELES 321 E 5TH STREET P 0 BOX 1150 PORT ANGELES WA 98362 C E R T I F I C A T E O F O C C U P A N C Y T E M P O R A R Y 8/15/07 9/15/07 06-30-14-6-2- 0440 -0000- 1809 MELODY LN PORT ANGELES THE UPLANDS 4A LOT 44 RESIDENTIAL HIGH DENSITY JAMES LEA HECKMAN VISION BUILDERS INC 360 452 -1186 Application number Description of Work Construction type Occupancy type Flood Zone Special conditions 08/15/2007 03 53 PM JLIERL top floor, two unity only ap 06- 00000099 000 000 RES NEW MULTI 5+ FAMILY VOID UNLESS SIGN BY BUILDIN G OF CAL WA 98362 occupancy PREPARED 8/13/07 9 42 33 INSPECTION TICKET PAGE 5 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 8/13/07 ADDRESS 1809 MELODY LN SUBDIV TENANT NBR HECKMAN CONDOMINIUM CONTRACTOR VISION BUILDERS INC PHONE (360) 452 1186 OWNER JAMES LEA HECKMAN PHONE (360) 452 6116 PARCEL 06 30 14 6 2 0440 0000 APPL NUMBER 06 00000099 RES NEW MULTI 5+ FAMILY REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS 07/30/2007 03 58 PM JLIERLY BL99 01 8/10/07 JLL BLDG FINAL 8/10/07 CA 08/09/2007 04 46 PM LPANGRLE CRAIG 461 3985 BLDG FINAL WANTS OCCUPANCY FOR TOP 2 UNITS 08/10/2007 04 21 PM JLIERLY Craig called and said they would not be ready and canncelled the inspection/j11 BL99 02 8/1 307 BLDG FINAL 1 4 08/13/2007 08 30 AM LPANGRLE CRAIG 461 3985 BLDG FINAL PERMIT ME 00 MECHANICAL PERMIT REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS ME1 01 4/20/07 JLL MECHANICAL ROUGH IN 4/20/07 AP 04/19/2007 03 46 PM PERMITS PAT 461 5278 CALL FIRST partial inspection top floor only 04/20/2007 04 20 PM JLIERLY ME6 01 4/20/07 JLL MECHANICAL GAS LINE 4/20/07 AP 04/20/2007 01 40 PM PERMITS PAT 461 5278 UNITS 3 4 5 6 partial inspection top floor only 04/20/2007 04 20 PM JLIERLY ME6 02 5/29/07 PB MECHANICAL GAS LINE 5/29/07 AP 05/25/2007 09 41 AM LPANGRLE JOHN 461 0445 CALL FIRST LP GAS PIPE FOR FIRST AND SECOND FLOORS 05/29/2007 04 29 PM PBARTHOL ME99 01 8/10/07 JLL MECHANICAL FINAL 8/10/07 CA 08/09/2007 04 47 PM LPANGRLE CRAIG 461 3985 MECHANICAL FINAL WANTS OCCUPANCY FOR TOP 2 UNITS 08/10/2007 04 21 PM JLIERLY craig called and said they would not be ready and canncelled the inspection /j11 ME99 02 8/1/07 J MECHANICAL FINAL 08/13/2007 08 43 AM LPANGRLE CRAIG 461 3985 MECHANICAL FINAL PERMIT PL 00 PLUMBING PERMIT REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS Date 3i o� BUILDING DIVISION CITY OF PORT ANGELES Correction Notice Job Located at ilk_ua Inspection of your work revealed that the following is not in accordance with the codes governing the work in this jurisdiction pi r 6 19 /L 9 L014 Z4, a ir z S Imo- These corrections must be made an are not to be covered until reinspection is made h corr ns have been made, please call c// P I for inspe tion _7 nspectorr f Building Division DO NOT REMOVE THIS TAG PREPARED 8/13/07 9 42 33 INSPECTION TICKET PAGE 6 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 8/13/07 ADDRESS 1809 MELODY LN SUBDIV TENANT NBR HECKMAN CONDOMINIUM CONTRACTOR VISION BUILDERS INC PHONE (360) 452 1186 OWNER JAMES LEA HECKMAN PHONE (360) 452 6116 PARCEL 06 30 14 6 2 0440 0000 APPL NUMBER 06 00000099 RES NEW MULTI 5+ FAMILY REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS PL1 01 7/31/06 JLL PLUMBING UNDER SLAB TIME 13 00 7/31/06 AP DEREK 452 1186 07/28/2006 09 59 AM DYASUMUR 07/31/2006 04 22 PM PBARTHOL PL2 01 4/16/07 JLL PLUMBING ROUGH IN TIME 01 00 4/16/07 AP 04/13/2007 01 31 PM PERMITS JOHN SHAY 461 0455 CALL 461 0455 SO JOHN CAN MEET YOU THERE FOR THE INSPECTION THIS IS A PARTIAL ROUGH IN 04/16/2007 03 36 PM JLIERLY PL2 02 5/08/07 JLL PLUMBING ROUGH IN 5/09/07 AP 05/07/2007 04 57 PM LPANGRLE PAT 461 5278 PLUMBING ROUGH IN 05/09/2007 08 58 AM JLIERLY PL2 03 5/29/07 PB PLUMBING ROUGH IN 5/29/07 AP 05/25/2007 09 38 AM LPANGRLE JOHN 461 0445 CALL FIRST ROUGH IN PLUMBING (FIRST FLOOR AND SECOND FLOOR) 05/29/2007 04 29 PM PBARTHOL PL99 01 8/10/07 JLL PLUMBING FINAL 8/10/07 CA 08/09/2007 04 48 PM LPANGRLE CRAIG 461 3985 PLUMBING FINAL WANTS OCCUPANCY FOR TOP 2 UNITS 08/10/2007 04 21 PM JLIERLY craig called and said they would not be ready and canncelled the inspection/j11 PL99 02 8/19(07 6,1, PLUMBING FINAL C R A I G 4617 85 44 AM LPANGRLE CRAIG 461 3985 PLUMBING FINAL COMMENTS AND NOTES FROM Chimacum Creek August 10, 2007 Jim Lierly, Building Inspector City of Port Angeles 321 E. 5 St. Port Angeles, WA 98362 RE Building Enclosure Inspection Results Chris King Aeon Home Inspection chnskrazeaeonhomemsnection _com cc Chris Jackson Vision Developers, Inc. 3705 South Critchfield Rd Port Angeles, WA 98362 PHONE NO. 360 379 3803 Aug. 14 2007 03 02PM P1 Aeon Home Inspection POB 224. Quilcene, WA 98376 (360) 774 -0637 RECEIVED AUG 14 2007 CITY BUILDING DIVISION ES Aeon Home Inspection has conducted periodic visual inspections relating the building enclosure of the structure located at 1809 Melody Lane, Port Angeles, WA 98362. Both the method of installation as well as the water penetration resistance testing of windows passed all requirements and specifications This letter serves as official notice that in the Opinion of Aeon Home Inspection, the building located at 1809 Melody Lane, Port Angeles, WA 98362 was found to be in substantial compliance with building enclosure design documents provided to me by Lindberg Smith Architects and Vision Developers. Inc. pursuant to Chapter 64.55 of the Revised Code of Washington. Aeon Home Inspection POB 224, Ouilcene, WA 98376 (360) 774 -0637 August 10, 2007 Jim Lierly, Building Inspector City of Port Angeles 321 E 5 St. Port Angeles, WA 98362 RE Building Enclosure Inspection Results Aeon Home Inspection has conducted periodic visual inspections relating the building enclosure of the structure located at 1809 Melody Lane, Port Angeles, WA 98362 Both the method of installation as well as the water penetration resistance testing of windows passed all requirements and specifications. This letter serves as official notice that in the Opinion of Aeon Home Inspection, the building located at 1809 Melody Lane, Port Angeles, WA 98362 was found to be in substantial compliance with building enclosure design documents provided to me by Lindberg Smith Architects and Vision Developers, Inc pursuant to Chapter 64 55 of the Revised Code of Washington. 6 4)4..4._. -4/Y Chris King Aeon Home Inspection chnskina a,aeonhomemsnection.com cc Chris Jackson Vision Developers, Inc 3705 South Crrtchfield Rd Port Angeles, WA 98362 Eli PREPARED 7/30/07 10 17 38 INSPECTION TICKET PAGE 4 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 7/30/07 ADDRESS 1809 MELODY LN SUBDIV TENANT NBR HECKMAN CONDOMINIUM CONTRACTOR VISION BUILDERS INC PHONE (360) 452 1186 OWNER JAMES LEA HECKMAN PHONE (360) 452 6116 PARCEL 06 30 14 6 2 0440 0000 APPL NUMBER 06 00000099 RES NEW MULTI 5+ FAMILY REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BLI 03 6/07/07 JLL BLDG INSULATION TIME 01 00 6/07/07 AP 06/06/2007 03 07 PM LPANGRLE PAT 461 5278 INSULATION 06/07/2007 04 06 PM JLIERLY BL9 08 6/18/07 JLL BLDG SHEARWALL 6/18/07 AP 06/18/2007 08 41 AM LPANGRLE PAT 461 5278 SHEARWALL FIRST FLOOR 06/18/2007 04 00 PM JLIERLY BL3 06 6/26/07 JLL BLDG FRAMING 6/26/07 DA 06/26/2007 08 14 AM LPANGRLE PAT 461 5278 FRAMING' REQUESTED AN 'OK TO MUD COVER SHEETROCK HARDWARE ON STAIRWAY INSPECTION 06/26/2007 04 04 PM JLIERLY frame on stairs require eng corrections on attachment of stairs to landing/j11 BLDR 02 7/09/07 JLL BLDG DRYWALL IBWP 7/09/07 AP 07/09/2007 08 49 AM LPANGRLE PAT 461 5278 SHEETROCK (FRONT WALL OF ELEVATOR) 07/09/2007 04 32 PM JLIERLY BL3 07 7/20/07 JLL BLDG FRAMING 7/20/07 AP 07/19/2007 04 58 PM LPANGRLE PAT 461 5278 FRAMING STAIRWELL TOWER 07/20/2007 03 29 PM JLIERLY BL3 08 7/25/07 JLL BLDG FRAMING TIME 01 00 7/25/07 DA 07/24/2007 03 59 PM LPANGRLE PAT 461 5278 FRAMING EAST STAIRWELL AFTERNOON 07/25/2007 04 28 PM JLIERLY verify stringer connections with engineer BL3 09 7/27/07 JLL BLDG FRAMING 7/27/07 DP 07/26/2007 03 43 PM LPANGRLE PAT 461 5278 FRAMING EAST STAIRWELL 07/27/2007 02 50 PM PBARTHOL WAS NOT READY 50 00 REINSPECTION FEE NEEDS TO BE PAID PRIOR TO NEXT INSPECTION 7/31/07 L I I BLDG FRAMING TIME 01 00 07/30/2007 08 26 AM LPANGRLE BL3 10 PAT 461 5278 FRAMING EAST STAIRWELL AFTERNOON INSPECTION PAT 461 5278 FRAMING 06/05/2007 03 59 PM JLIERLY COMMENTS AND NOTES PREPARED 7/27/07 10 53 32 INSPECTION TICKET PAGE 4 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 7/27/07 ADDRESS 1809 MELODY LN SUBDIV TENANT NBR HECKMAN CONDOMINIUM CONTRACTOR VISION BUILDERS INC PHONE (360) 452 1186 OWNER JAMES LEA HECKMAN PHONE (360) 452 6116 PARCEL 06 30 14 6 2 0440 0000 APPL NUMBER 06 00000099 RES NEW MULTI 5+ FAMILY REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS PAT 461 5278 FRAMING 06/05/2007 03 59 PM JLIERLY BLI 03 6/07/07 JLL BLDG INSULATION TIME 01 00 6/07/07 AP 06/06/2007 03 07 PM LPANGRLE PAT 461 5278 INSULATION 06/07/2007 04 06 PM JLIERLY BL9 08 6/18/07 JLL BLDG SHEARWALL 6/18/07 AP 06/18/2007 08 41 AM LPANGRLE PAT 461 5278 SHEARWALL FIRST FLOOR 06/18/2007 04 00 PM JLIERLY BL3 06 6/26/07 JLL BLDG FRAMING 6/26/07 DA 06/26/2007 08 14 AM LPANGRLE PAT 461 5278 FRAMING REQUESTED AN OK TO MUD COVER SHEETROCK HARDWARE ON STAIRWAY INSPECTION 06/26/2007 04 04 PM JLIERLY frame on stairs require eng corrections on attachment of stairs to landing /ill BLDR 02 7/09/07 JLL BLDG DRYWALL IBWP 7/09/07 AP 07/09/2007 08 49 AM LPANGRLE PAT 461 5278 SHEETROCK (FRONT WALL OF ELEVATOR) 07/09/2007 04 32 PM JLIERLY BL3 07 7/20/07 JLL BLDG FRAMING 7/20/07 AP 07/19/2007 04 58 PM LPANGRLE PAT 461 5278 FRAMING STAIRWELL TOWER 07/20/2007 03 29 PM JLIERLY BL3 08 7/25/07 JLL BLDG FRAMING TIME 01 00 7/25/07 DA 07/24/2007 03 59 PM LPANGRLE PAT 461 5278 FRAMING EAST STAIRWELL AFTERNOON 07/25/2007 04 28 PM JLIERLY verify stringer connections with engineer BL3 09 7/27/07 LL BLDG FRAMING .f 07/26/2007 03 43 PM LPANGRLE n S PAT 461 5278 e I l✓ FRAMING EAST STAIRWELL COMMENTS AND NOTES a{3_ BUILDING. DIVISION CITY OF PORT ANGELES Correction Notice Job Located at 1 509 /1 LI Inspection of your work revealed that the following is not in accordance with the codes governing the work in this jurisdiction FT ad. J S oc- r These corrections must be made and are not to be covered until reinspection is made When c rrections have been made, please call zi/ -7 for inspection Date a 7 spector for Building Division DO NOT REMOVE THIS TAG PREPARED 7/25/07 8 56 58 INSPECTION TICKET PAGE 14 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 7/25/07 ADDRESS 1809 MELODY LN SUBDIV TENANT NBR BECKMAN CONDOMINIUM CONTRACTOR VISION BUILDERS INC PHONE (360) 452 1186 OWNER JAMES LEA HECKMAN PHONE (360) 452 6116 PARCEL 06 30 14 6 2 0440 0000 APPL NUMBER 06 00000099 RES NEW MULTI 5+ FAMILY REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS PAT 461 5278 FRAMING 06/05/2007 03 59 PM JLIERLY BLI 03 6/07/07 JLL BLDG INSULATION TIME 01 00 6/07/07 AP 06/06/2007 03 07 PM LPANGRLE PAT 461 5278 INSULATION 06/07/2007 04 06 PM JLIERLY BL9 08 6/18/07 JLL BLDG SHEARWALL 6/18/07 AP 06/18/2007 08 41 AM LPANGRLE PAT 461 5278 SHEARWALL FIRST FLOOR 06/18/2007 04 00 PM JLIERLY BL3 06 6/26/07 JLL BLDG FRAMING 6/26/07 DA 06/26/2007 08 14 AM LPANGRLE PAT 461 5278 FRAMING' REQUESTED AN 'OK TO MUD COVER SHEETROCK HARDWARE ON STAIRWAY INSPECTION 06/26/2007 04 04 PM JLIERLY frame on stairs require eng corrections on attachment of stairs to landing/j11 BLDR 02 7/09/07 JLL BLDG DRYWALL IBWP 7/09/07 AP 07/09/2007 08 49 AM LPANGRLE PAT 461 5278 SHEETROCK (FRONT WALL OF ELEVATOR) 07/09/2007 04 32 PM JLIERLY BL3 07 7/20/07 JLL BLDG FRAMING 7/20/07 AP 07/19/2007 04 58 PM LPANGRLE PAT 461 5278 FRAMING STAIRWELL TOWER 07/20/2007 03 29 PM JLIERLY BL3 08 7/25/07 ///'��LL�L BLDG FRAMING TIME 01 00 07/24/2007 03 59 PM LPANGRLE PAT 461 5278 FRAMING EAST STAIRWELL AFTERNOON COMMENTS AND NOTES PREPARED 7/20/07 8 28 33 INSPECTION TICKET PAGE 4 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 7/20/07 ADDRESS 1809 MELODY LN SUBDIV TENANT NBR HECKMAN CONDOMINIUM CONTRACTOR VISION BUILDERS INC PHONE (360) 452 1186 OWNER JAMES LEA HECKMAN PHONE (360) 452 6116 PARCEL 06 30 14 6 2 0440 0000 APPL NUMBER 06 00000099 RES NEW MULTI 5+ FAMILY REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS PAT 461 5278 FRAMING 06/05/2007 03 59 PM JLIERLY BLI 03 6/07/07 JLL BLDG INSULATION TIME 01 00 6/07/07 AP 06/06/2007 03 07 PM LPANGRLE PAT 461 5278 INSULATION 06/07/2007 04 06 PM JLIERLY BL9 08 6/18/07 JLL BLDG SHEARWALL 6/18/07 AP 06/18/2007 08 41 AM LPANGRLE PAT 461 5278 SHEARWALL FIRST FLOOR 06/18/2007 04 00 PM JLIERLY BL3 06 6/26/07 JLL BLDG FRAMING 6/26/07 DA 06/26/2007 08 14 AM LPANGRLE PAT 461 5278 FRAMING REQUESTED AN OK TO MUD COVER SHEETROCK HARDWARE ON STAIRWAY INSPECTION 06/26/2007 04 04 PM JLIERLY frame on stairs require eng corrections on attachment of stairs to landing/j11 BLDR 02 7/09/07 JLL BLDG DRYWALL IBWP 7/09/07 AP 07/09/2007 08 49 AM LPANGRLE PAT 461 5278 SHEETROCK (FRONT WALL OF ELEVATOR) 07/09/2007 04 32 PM JLIERLY BL3 07 7/20/07 BLDG FRAMING 07/19/2007 04 58 PM LPANGRLE 111 PAT 461 5278 V FRAMING STAIRWELL TOWER COMMENTS AND NOTES J'U 1 10 07 09 25a V J. LVV vv Greg Hopf STAIR STRINGER SEE ARCH L THA222 -2 W/ 4-16d TOP NAILS AND 8-16d FACE NALS TO 6x'2 1 2LO9 L»_ 206 -780 -8819 p 1 I EPIRES OS►02/ o? 6x'2 BM STAR STR NGER AT 6x12 SCALE. 1 =1' -o PREPARED 7/09/07 9 08 45 INSPECTION TICKET PAGE 4 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 7/09/07 ADDRESS 1809 MELODY LN SUBDIV TENANT NBR HECKMAN CONDOMINIUM CONTRACTOR VISION BUILDERS INC PHONE (360) 452 1186 OWNER JAMES LEA HECKMAN PHONE (360) 452 6116 PARCEL 06 30 14 6 2 0440 0000 APPL NUMBER 06 00000099 RES NEW MULTI 5+ FAMILY REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS PAT 461 5278 FRAMING 06/05/2007 03 59 PM JLIERLY BLI 03 6/07/07 JLL BLDG INSULATION TIME 01 00 6/07/07 AP 06/06/2007 03 07 PM LPANGRLE PAT 461 5278 INSULATION 06/07/2007 04 06 PM JLIERLY BL9 08 6/18/07 JLL BLDG SHEARWALL 6/18/07 AP 06/18/2007 08 41 AM LPANGRLE PAT 461 5278 SHEARWALL FIRST FLOOR 06/18/2007 04 00 PM JLIERLY BL3 06 6/26/07 JLL BLDG FRAMING 6/26/07 DA 06/26/2007 08 14 AM LPANGRLE PAT 461 5278 FRAMING? REQUESTED AN OK TO MUD COVER SHEETROCK HARDWARE ON STAIRWAY INSPECTION 06/26/2007 04 04 PM JLIERLY frame on stairs require eng corrections on attachment of stairs to landing /ill BLDR 02 7/09/07 LL 4 BLDG DRYWALL IBWP 07/09/2007 08 49 AM LPANGRLE PAT 461 5278 SHEETROCK (FRONT WALL OF ELEVATOR) COMMENTS AND NOTES Jun 2S 07 01 33p Greg Hopf -0 STAIR STRINGER SEE ARCH'L "MEL O L 3 E- e a I •Kt- A C► 4 I 206- 780 -8819 P 3 Lea 12" x 18" CONC BEAM L 8x44/2 EA SIDE WI 2 -5/8 DIA BOLTS T STRINGER AND 2 -5/8" DIA RODS EPDXY TO CONC BEAM, EMBED 6" TRIM TOP EDGE ot. 1 450 d STAR STRNGER AT CONCRETE SCALE r.r-on EXPIRES 06/02/ n5 01 01 331, Greg HQ1,f STUD Tag TO STRIA STAIR LEER SE SI 4GER Tp STUD W A I- ST PAR 5VRNGER 1010(0 r PREPARED 6/26/07 9 17 55 INSPECTION TICKET CITY OF PORT ANGELES INSPECTOR JAMES LIERLY ADDRESS 1809 MELODY LN TENANT NBR HECKMAN CONDOMINIUM CONTRACTOR VISION BUILDERS INC OWNER JAMES LEA HECKMAN PARCEL 06 30 14 6 2 0440 0000 APPL NUMBER 06 00000099 RES NEW MULTI 5+ FAMILY REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS SUBDIV PAT 461 5278 FRAMING 06/05/2007 03 59 PM JLIERLY BLI 03 6/07/07 JLL BLDG INSULATION TIME 01 00 6/07/07 AP 06/06/2007 03 07 PM LPANGRLE PAT 461 5278 INSULATION 06/07/2007 04 06 PM JLIERLY BL9 08 6/18/07 JLL BLDG SHEARWALL 6/18/07 AP 06/18/2007 08 41 AM LPANGRLE PAT 461 5278 SHEARWALL FIRST FLOOR 06/18/2007 04 00 PM JLIERLY BL3 06 6/26/07 JLL BLDG FRAMING a 06/26/2007 08 14 AM LPANGRLE PAT 461 5278 FRAMING? REQUESTED AN OK TO MUD COVER SHEETROCK HARDWARE ON STAIRWAY INSPECTION COMMENTS AND NOTES Pcppyboo-) pita(' La-- 1.2 611- pc5-144 a/L 1-0 oP��l JV I PHONE (360) 452 1186 PHONE (360) 452 6116 5 1-4 41 we-,7 r- (1 l PAGE 4 DATE 6/26/07 PREPARED 6/18/07 10 50 24 INSPECTION TICKET PAGE 6 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 6/18/07 ADDRESS 1809 MELODY LN SUBDIV TENANT NBR HECKMAN CONDOMINIUM CONTRACTOR VISION BUILDERS INC PHONE (360) 452 1186 OWNER JAMES LEA HECKMAN PHONE (360) 452 6116 PARCEL 06 30 14 6 2 0440 0000 APPL NUMBER 06 00000099 RES NEW MULTI 5+ FAMILY REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS PAT 461 5278 FRAMING 06/05/2007 03 59 PM JLIERLY BLI 03 6/07/07 JLL BLDG INSULATION TIME 01 00 6/07/07 AP 06/06/2007 03 07 PM LPANGRLE PAT 461 5278 INSULATION 06/07/2007 04 06 PM JLIERLY BLDG SHEARWALL 06/18/2007 08 41 AM LPANGRLE PAT 461 5278 BL9 08 6/18/07 SHEARWALL FIRST FLOOR COMMENTS AND NOTES PREPARED 6/07/07 9 03 38 INSPECTION TICKET PAGE 4 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 6/07/07 ADDRESS' 1809 MELODY LN SUBDIV TENANT NBR BECKMAN CONDOMINIUM CONTRACTOR VISION BUILDERS INC PHONE (360) 452 1186 OWNER JAMES LEA HECKMAN PHONE (360) 452 6116 PARCEL 06 30 14 6 2 0440 0000 APPL NUMBER 06 00000099 RES NEW MULTI 5+ FAMILY REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BLI 03 6/07/07 PAT 461 5278 FRAMING 06/05/2007 03 59 PM JLIERLY BLDG INSULATION TIME 01 00 06/06/2007 03 07 PM LPANGRLE PAT 461 5278 INSULATION COMMENTS AND NOTES Jun -05 -2007 02 51am From- T -315 P 002/002 F -885 up! L■t.INEEKINti JUDGMENT FIRESTOP DETAIL PROJECT VISION BUILDERS 6 PLEX CONTRACTOR VISION F- RATING 3 -HR. TOP VIEW a 4 4 4 4 A Hilti Firestop Systems Designed by e 4 a.. a 1 PRECAST HOLLOW CORE CONCRETE FLOOR ASSEMBLY (MINIMUM 8" THICK) (3-HR. FIR -RATING). 2. SPIRAL WOUND SHEET METAL DUCT (MAXIMUM SIZE. 18" DIAMETER, MINIMUM 24 GA. THICKNESS). 3. MINIMUM 4" THICKNESS MINERAL WOOL (MINIMUM 4 PCF DENSITY) TIGHTLY PACKED AND INSTALLED WITHIN CORES FLUSH WITH PERIPHERY OF OPENING. 4. MINIMUM 3.1!2" THICKNESS MINERAL WOOL (MINIMUM 4 PCF DENSITY) TIGHTLY PACKED AND FLUSH WITH BOTTOM SURFACE OF CONCRETE FLOOR. 5. MINIMUM 4-112" DEPTH HILTI CP 637 FIRESTOP MORTAR FLUSH WITH TOP SURFACE OF CONCRETE FLOOR. NOTES 1 MAXIMUM SIZE OF OPENING 42" x 24" 2. ANNULAR SPACE MINIMUM 1", MAXIMUM 10" 3. (FORMING NOT SHOWN). USE A RIGID BOARD MATERIAL TO SUPPORT HILTI CP 637 FIRESTOP MORTAR DURING ITS INITIAL CURE (MINIMUM 24 HOURS). THIS ENGINEERING JUDGMENT REPRESENTS A FIRESTOP SYSTEM THAT WOULD BE EXPECTED TO PASS THE STATED RATINGS IF TESTED. (REFERENCE UL SYSTEM NO. C -AJ -1140, C -AJ -7084, C -AJ -8177) 1111.71, Inc. .Net 1 of 1 Drawing No. Tulsa, Oklahoma USA (800) 879 -8000 Scale Date Saving Lives through Innovation and Education SECTION A-A 5164 =1" June 05,2007 79033c 1116/5/2007) James Lierly Vision Builders Condo off Golf Course Road Page1I From Tracy Gudgel' <tracy @zenovic net> To <jlierly @cityofpa us> Date 6/5/2007 6 39 AM Subject: Vision Builders Condo off Golf Course Road Jim This office has performed inspections of epoxy anchors used on the building noted above. The epoxy anchors used as anchor bolts and holdown bolts were properly installed and inspected by this office Please call myself or Scott if you have any questions regarding this matter Tracy Gudgel Zenovic and Associates, Inc. ge-eici•f4ea IdecJo.& UqP o_y, LLt PREPARED 6/05/07 10 14 55 INSPECTION TICKET PAGE 3 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 6/05/07 ADDRESS 1809 MELODY LN SUBDIV TENANT NBR HECKMAN CONDOMINIUM CONTRACTOR VISION BUILDERS INC PHONE (360) 452 1186 OWNER JAMES LEA HECKMAN PHONE (360) 452 6116 PARCEL 06 30 14 6 2 0440 0000 APPL NUMBER 06 00000099 RES NEW MULTI 5+ FAMILY REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BAIR 03 5/02/07 JLL BLDG AIR SEAL 5/02/07 AP 05/01/2007 02 48 PM LPANGRLE PAT 461 5278 AIR SEAL 05/02/2007 04 51 PM JLIERLY BL3 02 5/02/07 JLL BLDG FRAMING 5/02/07 AP 05/01/2007 02 49 PM LPANGRLE PAT 461 5278 PARTIAL FRAMING 05/02/2007 04 51 PM JLIERLY BLDR 01 5/03/07 JLL BLDG DRYWALL IBWP 5/03/07 AP 05/03/2007 09 02 AM LPANGRLE PAT 461 5278 3RD FLOOR 5/8 DRYWALL FIREWALL 05/03/2007 04 35 PM JLIERLY BL9 07 5/08/07 JLL BLDG SHEARWALL 5/09/07 AP 05/07/2007 05 00 PM LPANGRLE PAT 461 5278 SHEARWALL SECOND FLOOR EAST SIDE 05/09/2007 08 58 AM JLIERLY BLI 02 5/16/07 PB BLDG INSULATION 5/16/07 AP 05/15/2007 03 23 PM LPANGRLE PAT 461 5278 INSULATION ON AN ELEVATOR SO HE CAN COVER IT 05/16/2007 01 07 PM PBARTHOL BL3 03 5/29/07 PB BLDG FRAMING 5/29/07 AP FRAMING IN THE GARAGE ONLY 05/29/2007 04 29 PM PBARTHOL BAIR 04 6/04/07 JLL BLDG AIR SEAL 6/04/07 DA 06/04/2007 10 05 AM LPANGRLE PAT 461 5278 AIR SEAL FIRE SEAL 06/04/2007 04 40 PM JLIERLY eng letter for epoxy bolts /seal fur downs w gwb /seal penetraition at common wall /provide ul listed fire assembly at floor ceil assembly at garage and 1st floor/j11 BL3 04 6/04/07 JLL BLDG FRAMING 6/04/07 DA 06/04/2007 10 06 AM LPANGRLE PAT 461 FRAMING OK TO INSULATE INSPECTION 06/04/2007 04 40 PM JLIERLY eng letter for epoxy bolts /seal fur downs w gwb /seal penetraition at common wall /provide ul listed fire assembly at floor ceil assembly at garage and 1st floor/j11 BAIR 05 6/05/07 Ja BLDG AIR SEAL It }4 06/05/2007 08 40 AM LPANGRLE PAT 461 5278 AIR SEAL BL3 05 6/05/07 J L BLDG FRAMING LI 06/05/2007 08 40 AM LPANGRLE PAT 461 5278 CONTINUED ONTO NEXT PAGE PREPARED 6/04/07 10 35 11 CITY OF PORT ANGELES ADDRESS TENANT NBR CONTRACTOR OWNER PARCEL APPL NUMBER REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BAIR 03 5/02/07 JLL 5/02/07 AP BL3 02 5/02/07 JLL 5/02/07 AP BLDR 01 5/03/07 JLL 5/03/07 AP BL9 07 5/08/07 JLL 5/09/07 AP BLI 02 5/16/07 PB 5/16/07 AP BL3 03 5/29/07 PB 5/29/07 AP BAIR 04 6/0 BL3 04 6/04/07 1809 MELODY LN HECKMAN CONDOMINIUM VISION BUILDERS INC JAMES LEA HECKMAN 06 30 14 6 2 0440 0000 06 00000099 RES NEW MULTI 5+ FAMILY INSPECTION TICKET INSPECTOR JAMES LIERLY SUBDIV COMMENTS AND NOTES PHONE (360) 452 1186 PHONE (360) 452 6116 BLDG AIR SEAL 05/01/2007 02 48 PM LPANGRLE PAT 461 5278 AIR SEAL 05/02/2007 04 51 PM JLIERLY BLDG FRAMING 05/01/2007 02 49 PM LPANGRLE PAT 461 5278 PARTIAL FRAMING 05/02/2007 04 51 PM JLIERLY BLDG DRYWALL IBWP 05/03/2007 09 02 AM LPANGRLE PAT 461 5278 3RD FLOOR 5/8 DRYWALL FIREWALL 05/03/2007 04 35 PM JLIERLY BLDG SHEARWALL 05/07/2007 05 00 PM LPANGRLE PAT 461 5278 SHEARWALL SECOND FLOOR EAST SIDE 05/09/2007 08 58 AM JLIERLY BLDG INSULATION 05/15/2007 03 23 PM LPANGRLE PAT 461 5278 INSULATION ON AN ELEVATOR SO HE CAN COVER IT 05/16/2007 01 07 PM PBARTHOL BLDG FRAMING FRAMING IN THE GARAGE ONLY 05/29/2007 04 29 PM PBARTHOL BLDG AIR SEAL 06/04/2007 10 05 AM LPANGRLE PAT 461 5278 AIR SEAL FIRE SEAL BLDG FRAMING 06/04/2007 10 06 AM LPANGRLE PAT 461 5278 FRAMING OK TO INSULATE INSPECTION PAGE 11 DATE 6/04/07 ca y i 6 (0 j C old P c171 Pd 1,6-1177-/L— rkL4 fee y f7v14--y opeA 10(44.41-Ltis 41o6g:A1 0Y-ttis- PREPARED 5/29/07 10 50 40 INSPECTION TICKET PAGE 4 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 5/29/07 ADDRESS 1809 MELODY LN SUBDIV TENANT NBR BECKMAN CONDOMINIUM CONTRACTOR VISION BUILDERS INC PHONE (360) 452 1186 OWNER JAMES LEA HECKMAN PHONE (360) 452 6116 PARCEL 06 30 14 6 2 0440 0000 APPL NUMBER 06 00000099 RES NEW MULTI 5+ FAMILY REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BAIR 03 5/02/07 JLL BLDG AIR SEAL 5/02/07 AP 05/01/2007 02 48 PM LPANGRLE PAT 461 5278 AIR SEAL 05/02/2007 04 51 PM JLIERLY BL3 02 5/02/07 JLL BLDG FRAMING 5/02/07 AP 09/01/2007 02 49 PM LPANGRLE PAT 461 5278 PARTIAL FRAMING 05/02/2007 04 51 PM JLIERLY BLDR 01 5/03/07 JLL BLDG DRYWALL IBWP 5/03/07 AP 05/03/2007 09 02 AM LPANGRLE PAT 461 5278 3RD FLOOR 5/8 DRYWALL FIREWALL 05/03/2007 04 35 PM JLIERLY BL9 07 5/08/07 JLL BLDG SHEARWALL 5/09/07 AP 05/07/2007 05 00 PM LPANGRLE PAT 461 5278 SHEARWALL SECOND FLOOR EAST SIDE 05/09/2007 08 58 AM JLIERLY BLI 02 5/16/07 PB BLDG INSULATION 5/16/07 AP 05/15/2007 03 23 PM LPANGRLE PAT 461 5278 INSULATION ON AN ELEVATOR SO HE CAN COVER IT 05/16/2007 01 07 PM PBARTHOL �.S�FFH�1 5/29/07 JLL DLDO FRAMING HOLD DOWNS 05/25/2007 01 46 PM LPANGRLE ,j• .rte PAT 461 5278 l FRAMING METAL STUDS IN GARAGE PERMIT ME 00 MECHANICAL PERMIT REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS ME1 01 4/20/07 JLL MECHANICAL ROUGH IN 4/20/07 AP 04/19/2007 03 46 PM PERMITS PAT 461 5278 CALL FIRST partial inspection top floor only 04/20/2007 04 20 PM JLIERLY ME6 01 4/20/07 JLL MECHANICAL GAS LINE 4/20/07 AP 04/20/2007 01 40 PM PERMITS PAT 461 5278 UNITS 3 4 5 6 partial inspection top floor only 04/20/2007 04 20 PM JLIERLY ME6 02 2,/29/07 JL n MECHANICAL GAS LINE M n 05/25/2007 09 41 AM LPANGRLE JOHN 461 0445 CALL FIRST LP GAS PIPE FOR FIRST AND SECOND FLOORS PERMIT PL 00 PLUMBING PERMIT PREPARED 5/29/07 10 50 40 INSPECTION TICKET PAGE 5 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 5/29/07 ADDRESS 1809 MELODY LN SUBDIV TENANT NBR HECKMAN CONDOMINIUM CONTRACTOR VISION BUILDERS INC PHONE (360) 452 1186 OWNER JAMES LEA HECKMAN PHONE (360) 452 6116 PARCEL 06 30 14 6 2 0440 0000 APPL NUMBER 06 00000099 RES NEW MULTI 5+ FAMILY REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS PL1 01 7/31/06 JLL PLUMBING UNDER SLAB TIME 13 00 7/31/06 AP DEREK 452 1186 07/28/2006 09 59 AM DYASUMUR 07/31/2006 04 22 PM PBARTHOL PL2 01 4/16/07 JLL PLUMBING ROUGH IN TIME 01 00 4/16/07 AP 04/13/2007 01 31 PM PERMITS JOHN SHAY 461 0455 CALL 461 0455 SO JOHN CAN MEET YOU THERE FOR THE INSPECTION THIS IS A PARTIAL ROUGH IN 04/16/2007 03 36 PM JLIERLY PL2 02 5/08/07 JLL PLUMBING ROUGH IN 5/09/07 AP 05/07/2007 04 57 PM LPANGRLE PAT 461 5278 PLUMBING ROUGH IN 05/09/2007 08 58 AM JLIERLY PL2 03 5/29/07 JLL PLUMBING ROUGH IN 05/25/2007 09 38 AM LPANGRLE 5/'-5 JOHN 461 0445 CALL FIRST ROUGH IN PLUMBING (FIRST FLOOR AND SECOND FLOOR) COMMENTS AND NOTES PREPARED 5/16/07 12 25 24 INSPECTION TICKET PAGE 7 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 5/16/07 ADDRESS 1809 MELODY LN SUBDIV TENANT NBR HECKMAN CONDOMINIUM CONTRACTOR VISION BUILDERS INC PHONE (360) 452 1186 OWNER JAMES LEA HECKMAN PHONE (360) 452 6116 PARCEL 06 30 14 6 2 0440 0000 APPL NUMBER 06 00000099 RES NEW MULTI 5+ FAMILY REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BAIR 03 5/02/07 JLL BLDG AIR SEAL 5/02/07 AP 05/01/2007 02 48 PM LPANGRLE PAT 461 5278 AIR SEAL 05/02/2007 04 51 PM JLIERLY BL3 02 5/02/07 JLL BLDG FRAMING 5/02/07 AP 05/01/2007 02 49 PM LPANGRLE PAT 461 5278 PARTIAL FRAMING 05/02/2007 04 51 PM JLIERLY BLDR 01 5/03/07 JLL BLDG DRYWALL IBWP 5/03/07 AP 05/03/2007 09 02 AM LPANGRLE PAT 461 5278 3RD FLOOR 5/8 DRYWALL FIREWALL 05/03/2007 04 35 PM JLIERLY BL9 07 5/08/07 JLL BLDG SHEARWALL 5/09/07 AP 05/07/2007 05 00 PM LPANGRLE PAT 461 5278 SHEARWALL SECOND FLOOR EAST SIDE 05/09/2007 08 58 AM JLIERLY BLI 02 5/16/07 JLL BLDG INSULATION 05/15/2007 03 23 PM LPANGRLE PAT 461 5278 INSULATION ON AN ELEVATOR SO HE CAN COVER IT COMMENTS AND NOTES PREPARED 5/03/07 9 42 21 INSPECTION TICKET PAGE 3 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 5/03/07 ADDRESS 1809 MELODY LN SUBDIV TENANT NBR HECKMAN CONDOMINIUM CONTRACTOR VISION BUILDERS INC PHONE (360) 452 1186 OWNER JAMES LEA HECKMAN PHONE (360) 452 6116 PARCEL 06 30 14 6 2 0440 0000 APPL NUMBER 06 00000099 RES NEW MULTI 5+ FAMILY REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BAIR 03 5/02/07 JLL BLDG AIR SEAL 5/02/07 AP 05/01/2007 02 48 PM LPANGRLE PAT 461 5278 AIR SEAL 05/02/2007 04 51 PM JLIERLY BL3 02 5/02/07 JLL BLDG FRAMING 5/02/07 AP 05/01/2007 02 49 PM LPANGRLE PAT 461 5278 PARTIAL FRAMING 05/02/2007 04 51 PM JLIERLY BLDR 01 5/03/0 BLDG -IB 02 05/03/2007 09 02 AM LPANGRLE PAT 461 5278 4 l 3RD FLOOR 5/8 DRYWALL FIREWALL a COMMENTS AND IOTES 1-ks IA-) Z. J so-0 PREPARED 5/08/07 12 10 52 INSPECTION TICKET PAGE 3 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 5/08/07 ADDRESS 1809 MELODY LN SUBDIV TENANT NBR HECKMAN CONDOMINIUM CONTRACTOR VISION BUILDERS INC PHONE (360) 452 1186 OWNER JAMES LEA HECKMAN PHONE (360) 452 6116 PARCEL 06 30 14 6 2 0440 0000 APPL NUMBER 06 00000099 RES NEW MULTI 5+ FAMILY REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BAIR 03 5/02/07 JLL BLDG AIR SEAL 5/02/07 AP 05/01/2007 02 48 PM LPANGRLE PAT 461 5278 AIR SEAL 05/02/2007 04 51 PM JLIERLY BL3 02 5/02/07 JLL BLDG FRAMING 5/02/07 AP 05/01/2007 02 49 PM LPANGRLE PAT 461 5278 PARTIAL FRAMING 05/02/2007 04 51 PM JLIERLY BLDR 01 5/03/07 JLL BLDG DRYWALL IBWP 5/03/07 AP 05/03/2007 09 02 AM LPANGRLE PAT 461 5278 3RD FLOOR 5/8 DRYWALL FIREWALL 05/03/2007 04 35 PM JLIERLY BL9 07 5/08/07 JA 4 BLDG SHEARWALL 05/07/2007 05 00 PM LPANGRLE PAT 461 5278 SHEARWALL SECOND FLOOR EAST SIDE PERMIT PL 00 PLUMBING PERMIT REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS PL1 01 7/31/06 JLL PLUMBING UNDER SLAB TIME 13 00 7/31/06 AP DEREK 452 1186 07/28/2006 09 59 AM DYASUMUR 07/31/2006 04 22 PM PBARTHOL PL2 01 4/16/07 JLL PLUMBING ROUGH IN TIME 01 00 4/16/07 AP 04/13/2007 01 31 PM PERMITS JOHN SHAY 461 0455 CALL 461 0455 SO JOHN CAN MEET YOU THERE FOR THE INSPECTION THIS IS A PARTIAL ROUGH IN 04/16/2007 03 36 PM JLIERLY PL2 02 5/0/07 PLUMBING ROUGH IN 05/07/2007 04 57 PM LPANGRLE PAT 461 5278 PLUMBING ROUGH IN COMMENTS AND NOTES PREPARED 5/02/07 8 20 37 INSPECTION TICKET PAGE 3 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 5/02/07 ADDRESS 1809 MELODY LN SUBDIV TENANT NBR HECKMAN CONDOMINIUM CONTRACTOR VISION BUILDERS INC PHONE (360) 452 1186 OWNER JAMES LEA HECKMAN PHONE (360) 452 6116 PARCEL 06 30 14 6 2 0440 0000 APPL NUMBER 06 00000099 RES NEW MULTI 5+ FAMILY REQUESTED TYP /SQ COMPLETED BAIR 03 5/02/07 BL3 02 5/02/07 INSP RESULT DESCRIPTION RESULTS /COMMENTS BLDG AIR SEAL 05/01/2007 02 48 PM LPANGRLE PAT 461 5278 AIR SEAL BLDG FRAMING 05/01/2007 02 49 PM LPANGRLE PAT 461 5278 PARTIAL FRAMING COMMENTS AND NOTES PREPARED 4/25/07 8 41 27 CITY OF PORT ANGELES ADDRESS 1809 MELODY LN SUBDIV TENANT NBR HECKMAN CONDOMINIUM CONTRACTOR VISION BUILDERS INC PHONE (360) 452 1186 OWNER JAMES LEA HECKMAN PHONE (360) 452 6116 PARCEL 06 30 14 6 2 0440 0000 APPL NUMBER 06 00000099 RES NEW MULTI 5 FAMILY REQUESTED TYP /SQ COMPLETED BL9 02 2/06/07 2/06/07 BL9 03 2/09/07 2/09/07 BL9 04 2/14/07 2/14/07 BL9 05 2/16/07 2/16/07 BAIR 02 4/20/07 4/20/07 BAIR 01 BL3 01 4/20/07 4/20/07 BLI 01 4/23/07 4/23/07 BL5 01 JLL AP JLL AP JLL AP JLL AP 4/20/07 JLL 4/20/07 AP JLL AP JLL AP 4/25/07 JAL BL9 06 4/25/07 INSP DESCRIPTION RESULT RESULTS /COMMENTS PB AP JLL INSPECTION TICKET INSPECTOR JAMES L LIERLY BUILDING SHEARWALL 02/06/2007 08 37 AM PERMITS pat 461 5278 02/06/2007 04 01 PM PBARTHOL EAST END OF BLDG 2ND AND 3RD FLOOR SHEARWALL OK BUILDING SHEARWALL 02/08/2007 02 55 PM PERMITS PAT 461 9169 02/09/2007 04 33 PM JLIERLY w and sw corner /j11 BUILDING SHEARWALL 02/13/2007 01 23 PM PERMITS 461 5278 call first 02/14/2007 04 02 PM JLIERLY BUILDING SHEARWALL 02/16/2007 11 21 AM PERMITS 461 5278 02/16/2007 03 35 PM JLIERLY BUILDING AIR SEAL 04/19/2007 01 36 PM PERMITS PAT 461 5278 FIRE SEAL CALL FIRST partial inspection top floor only 04/20/2007 04 20 PM JLIERLY BUILDING AIR SEAL 04/19/2007 01 35 PM PERMITS PAT 461 5278 CALL FIRST partial inspection top floor only 04/20/2007 04 20 PM JLIERLY BUILDING FRAMING 04/19/2007 03 44 PM PERMITS PAT 461 5278 CALL FIRST partial inspection top floor only 04/20/2007 04 20 PM JLIERLY BUILDING INSULATION 04/23/2007 09 08 AM LPANGRLE PAT 461 5278 04/23/2007 04 54 PM JLIERLY BUILDING F,.=inn% 04/24/2007 11 50 AM LPANGRLE TYLER 452 9813 CHIMNEY BUILDING SHEARWALL 04/24/2007 11 52 AM. LPANGRLE PAT 461 5278 COMMENTS AND NOTES PAGE 2 DATE 4/25/07 f) 17-akTel ges,_k Co T x 6445 PREPARED 4/23/07 12 23 31 INSPECTION TICKET PAGE 2 CITY OF PORT ANGELES INSPECTOR JAMES L LIERLY DATE 4/23/07 ADDRESS 1809 MELODY LN SUBDIV TENANT NBR HECKMAN CONDOMINIUM CONTRACTOR VISION BUILDERS INC PHONE (360) 452 1186 OWNER JAMES LEA HECKMAN PHONE (360) 452 6116 PARCEL 06 30 14 6 2 0440 0000 APPL NUMBER 06 00000099 RES NEW MULTI 5+ FAMILY REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BL9 02 2/06/07 PB BUILDING SHEARWALL 2/06/07 AP 02/06/2007 08 37 AM PERMITS pat 461 5278 02/06/2007 04 01 PM PBARTHOL EAST END OF BLDG 2ND AND 3RD FLOOR SHEARWALL OK BL9 03 2/09/07 JLL BUILDING SHEARWALL 2/09/07 AP 02/08/2007 02 55 PM PERMITS PAT 461 9169 02/09/2007 04 33 PM JLIERLY w and sw corner /ill BL9 04 2/14/07 JLL BUILDING SHEARWALL 2/14/07 AP 02/13/2007 01 23 PM PERMITS 461 5278 call first 02/14/2007 04 02 PM JLIERLY BL9 05 2/16/07 JLL BUILDING SHEARWALL 2/16/07 AP 02/16/2007 11 21 AM PERMITS 461 5278 02/16/2007 03 35 PM JLIERLY BAIR 02 4/20/07 JLL BUILDING AIR SEAL 4/20/07 AP 04/19/2007 01 36 PM PERMITS PAT 461 5278 FIRE SEAL CALL FIRST partial inspection top floor only 04/20/2007 04 20 PM JLIERLY BAIR 01 4/20/07 JLL BUILDING AIR SEAL 4/20/07 AP 04/19/2007 01 35 PM PERMITS PAT 461 5278 CALL FIRST partial inspection top floor only 04/20/2007 04 20 PM JLIERLY BL3 01 4/20/07 JLL BUILDING FRAMING 4/20/07 AP 04/19/2007 03 44 PM PERMITS PAT 461 5278 CALL FIRST partial inspection top floor only 04/20/2007 04 20 PM JLIERLY BLI 01 4/23/07 .Ij,L BUILDING INSULATION 04/23/2007 09 08 AM LPANGRLE PAT 461 5278 COMMENTS AND NOTES PREPARED 4/20/07 8 41 35 INSPECTION TICKET PAGE 2 CITY OF PORT ANGELES INSPECTOR JAMES L LIERLY DATE 4/20/07 ADDRESS 1809 MELODY LN SUBDIV TENANT NBR HECKMAN CONDOMINIUM CONTRACTOR VISION BUILDERS INC PHONE (360) 452 1186 OWNER JAMES LEA HECKMAN PHONE (360) 452 6116 PARCEL 06 30 14 6 2 0440 0000 APPL NUMBER 06 00000099 RES NEW MULTI 5+ FAMILY REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BL9 02 2/06/07 PB BUILDING SHEARWALL 2/06/07 AP 02/06/2007 08 37 AM PERMITS pat 461 5278 02/06/2007 04 01 PM PBARTHOL EAST END OF BLDG 2ND AND 3RD FLOOR SHEARWALL OK BL9 03 2/09/07 JLL BUILDING SHEARWALL 2/09/07 AP 02/08/2007 02 55 PM PERMITS PAT 461 9169 02/09/2007 04 33 PM JLIERLY w and sw corner/j11 BL9 04 2/14/07 JLL BUILDING SHEARWALL 2/14/07 AP 02/13/2007 01 23 PM PERMITS 461 5278 call first 02/14/2007 04 02 PM JLIERLY BL9 05 2/16/07 .JLL BUILDING SHEARWALL 2/16/07 AP 02/16/2007 11 21 AM PERMITS 461 5278 02/16/2007 03 35 PM JLIERLY BAIR 01 4/20/07 JLL BUILDING AIR SEAL 04/19/2007 01 35 PM PERMITS PAT 4"61 5278 CALL FIRST BAIR 02 4/20/07 JLL BUILDING AIR SEAL 04/19/2007 01 36 PM PERMITS PAT 461 5278 FIRE SEAL CALL FIRST BL3 01 4/20/07 JLL BUILDING FRAMING 04/19/2007 03 44 PM PERMITS PAT 461 5278 CALL FIRST PERMIT ME 00 MECHANICAL PERMIT REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS ME1 01 4/20/07 JLL MECHANICAL ROUGH IN 04/19/2007 03 46 PM PERMITS PAT 461 5278 CALL FIRST COMMENTS AND NOTES C Vre> A-of I oot, 1 k Se la-0,C Lit- 4,9p PREPARED 4/16/07 8 27 12 INSPECTION TICKET PAGE 1 CITY OF PORT ANGELES INSPECTOR JAMES L LIERLY DATE 4/16/07 ADDRESS 1809 MELODY LN SUBDIV TENANT NBR HECKMAN CONDOMINIUM CONTRACTOR VISION BUILDERS INC PHONE (360) 452 1186 OWNER JAMES LEA HECKMAN PHONE (360) 452 6116 PARCEL 06 30 14 6 2 0440 0000 APPL NUMBER 06 00000099 RES NEW MULTI 5+ FAMILY PERMIT PL 00 P LUMBING PERMI T REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS PL1 01 7/31/06 JLL 7/31/06 AP PL2 01 4/16/07 PLUMBING UNDER SLAB TIME 13 00 DEREK 452 1186 07/28/2006 09 59 AM DYASUMUR 07/31/2006 04 22 PM PBARTHOL PLUMBING ROUGH IN TIME 01 00 04/13/2007 01 31 PM PERMITS JOHN SHAY 461 0455 CALL 461 0455 SO JOHN CAN MEET YOU THERE FOR THE INSPECTION THIS IS A PARTIAL ROUGH IN COMMENTS AND NOTES AZ' ,-r -1:1? .1 CITY OF FORT A. N., Ht#•--- FIRE 'DEPAgMISTEN:T PERMIT i§p.1-4,04:P.O."0:rArsolts-'„_ 'JI4 8362 911, r. RA* W ,4n ASSESSOR AJUMBER namg,-41.' ,4'5 40 1, aCIP) 1', „.•P Nani:OV; ititfifshiiitkie>n4 076 ,:cr-qtaaot 9,9 valuatAft -1; rt; -t.. f v ,1,_,_:,_, K... A t• T3RE, ;,SPI?:ISTKLER -13.-Rap t RESIDENZIAL ,FIRE SSMINIKLER 4 „,n•i umbtA '96 l• 4• 4-k 114 11 h''' .4.? 4 s a C) a in ;I ,T all .C. e a /:?.:0/ 0 9116 Pp 1 't-ha't 'Per BASE- FgE, 2N•4 1889, 06 30 Y41,- l047441-40 CCINDOMATK 'RES -nNEW t, tri4 -T'Tfl T ,REs1i5EgtdAh,l-hdi-LAggg40 91'30;4;5 rf A a ep-,0110•4404, void l'e,V0.110fOttp,r hOtotanii tra 'qatd ERBRII ilif.: ,i, ENT•BE84:, VR,•.§' -'05, Nr .;.I_- on4.. n_ e :4 .,.•,r IF-...r,,, ,h, e".4.%14;a:••' "V WA ;§;a1s0-3' sziEs?1 4/ 347,2,2i” b0 3.1:6: 'oArT6 ,s :POR.:1 1 'T A ,:',A•A'r,414,.,&•.".0141A., •43(.60*.i.;•4 8 4/ ne Znfoiffiaripri: .0.'0.(1 'quo '6.. 1.131■FTIF, BON ,,6'• ,r.• w It•- ,1•4, t 4.. T-IIIA '.VOTA.B":".. 9 1 4 'BOTT... C-0„,VE BEI' '6 Ai i. .H.4.g15: '8ifitEAVE• 1A,..t.rt•-• ,.,•it, ..AV*..' i NUMBER, 4 0Et •ST012,I .4,. 6 d6viiiirgE NUMBER OR 1\II‘TS t CUM age 4,' [2 .1"977 •„,4 31 i 4)._ k 1' k: w'',1„ a., -i,, i 11 :r4, Y t ,.•.,T, -r••,•--- 10f.",010, ,,17,-..2:pi r' 'Sr 4" "Iv 4 Comments fbwne e, k 1 2i• t'••;''''''ff 4 esponLIffeC, ...i.tit ..0:14 a1 r 4rm•.". :1 .1: •,.,r inspect e .0„e±.• tl"..',CuAreti't'S. 5 -.q.'• NFPA -,4 Y., *61. 7 ,Y 1 N: r -4- iic'' 4,,• -I. -.In '4 A- 'Oa Pig, PATB,Wg ftt .7,. -t•t- 4 't••=-.. t .v plans o t;.-F6•4_1,s• t a 4 "a* The. ;d7 now., ,a.i. -Prt•-N- 1"?.4••,;s. Piihk- s' St".46 tem, 11 :i 7 f Ilpw„ stf ?at- ,c1 11p ?a.pe 1 ..1 n4. t 11 a mper d'icson th,e„f 1." h. At 4 '45,, l'. anc #thIV smok, r4"'M .2' i i o,.• Sliati,ttg; iticCei ff.° t ".kn v p •r..." .A,'•ot..,,,..e•abk., ,•••,'S' 4,,. '1, 01' ti 'pl'67',,room 1,:zontainIzit, stne, F-2kg B 111„175 X or •nti'6K Mh•g•"Pid;t:Vetts 4ViVIE" ii• iiw011 Fecy.:1 'PrMlt"11 J. f,...e.'47,7 4 i.. k. Ftsficine, --■'n- .4, tt T.-- •.4 .X4 1 'irs plans ..1., wallI, srequ ?seperae perm f.orrt.t.iety, 1 r'..:2.3" l'Jk s x "f"•' '7 1' 4, '4••••tf#.,21 r. ,i's8r egtittrted? •.'t, 04 4, ■''t mAio Ag.w,g g -fiL'Ikk-'4'r,s_•_44..m!`",h4,,,,t„7.•hte-Volitrarit,,,,,,,e'Vr,,,. "lwi.,VIh,,,,e-"It-,,..'e---5,4-P owef*tfkrk- '5, the .:W" V ''*2' '1 fra ics ,:i.,.t..43kr,tt,i_tg'ii*.,,Shgt.41•1er•e-mten A h.:4fi •••-.4t k'1ffi'; j- 0 AM ubub .4,, kh i .1A Idi,x3x.),1,0c,Kth,,,,.. -40"t w q,.„1_ EC1',,i 'bhe 'A.i. t• .K la I. lA It ..4 4 #4,• ®tcorniein :18•Crays nop4Pt ,i,r,spt.r.,pti eadlkfittexahlaci 14N1e011S' 4U .4, 1 t and4471.41.44,0:' .',i1W OffeOlAg00-54 t bf,thi perriattAclos Pf6M4' ifikliV-10tAkt: tr c'114kte=kula e tlifg?,htt 11 '4 20 9P 44 2t •1 V0101.t, ,E) 040AtTerzcit•Cdrner C ont r#OQYV r 1V...i ;4•10" Mt/ 4f, -4 7' 4 i ".4 .;T s' i 1 .44 •1 .frfi. r FOE ,Vitdergrotind:piPing tested ,IIrtc1,04. Inteiiioll'solipilygliydr tested liteKtojAmilgyinspection Di-YrSySieffi4alr, tested at 40 psi (24 hours) FIRERM 3V;74 Sp101delgtirat BOP, Rough4i1ifspection AlarirrifAS1 Ll Undergtuldkpiping,,inspectionAptessure test Ab'Orc:__?it Linspecticiniptcssure test TOPlagtentaiiiie f Applance nspection tk--gas Vara* i STORAGE TANK (UST) ABANDONMENT Ivo 4= 'a,.10W4efi00 TY 'Remo aminable/Cornbustible liquids c:1 -:-4-'41PAKIR.h Ka-b a rld°ned tigigegrldrinien't final „.„...katartmeage. PERM% OTHER (specify) perfnnal GEN.mticriivimENTs Date Passed tio7 •oinploWtby cotOctoi." Test #1 :Piping pressure:lest Time initiated, Test#,2‘ Pipingpressure.tes 11meirirtiated FIRE PERMIT INSPECTION RECORD 445f5.--for fire inspections. Please proyide a minimum 24:-hPul notice. It nmawful tO:c'ToikWittitafe atf Inspected and accepted. Post permit tn, a cortspicnon8 aNatibil. 'fi, fl If 4 KEEP PERMIT CARD AND APPROVED PLANS AT -JO). SITE 31. ‘'l c0( Meats I 4 4- 5 Tkiv nSf -5- re ii Trans f 1'4 .fii i. pplabal-liiitb rt filDPIL tirlitfrb .i54 numbe i ;PA f'''' ;spe o be a, land Comments ‘...V1 -r 4 Qg at aipn 4ef ormatd on 7-•-' te.Avf,fisi, i,.,bi.i.tid :ss. :44.- Doors" b 6.4 bairns f ire. i alici.'°f-sire alarm control panel jiiii.ipt- be •••t•"" re; t .,:t. ..t. ii 4 2V2Tt, plqr vSROS Vie.•.A.pr,O,p'osat is for a 6 4r Rt dOmi-nbilimt ti,4 Ole, l3-11:1 for tot aa• z4ioteTe0 rale of 28% .rasue:Stag,e: noted A c ktV itv ZOO ,CI da16:iii iionS and ek ',tr c'i-,32 are b! V' t•fi? ins tad: fa bi oii: at c4ab4mtbVMp e A cost lma e 4 k 7 4 A l J i b e prepared: af ter .9.a.. rpcp.f.ihTb'eMents are 0 .t. 1."4-Hm411ffi 'OMMAiN g„. b .A. 6i 1#.4kOt 0 'b&dk f ill, or ';d hour .advance led' :t '•;4 ''`-t Each ',,....,V4 w, t li aVe its own water aficb seprate 1 q 314 1 4AN 1:0:.**adk f I o'..4 peiz b'ri i(..t.enti-'4 (pv.c. water l r: 4. 4g6 ..orr.v,mc ,..,......0.Me16,61 Lane fA-r;l0 e 14111 ,require a .4.1 4,*Pe,' i it 'b T.44be Main so!. $t1r.:4Veiiiay.b; ri 'bp.j...tiewalka4te. ,Stta4tClari:40. t qktibt- V)tp6'S eel 'as4regatat$ Ibip thei, City glib' .4p,- .7,,i.y An ibspet.ioTi .b, „4 Works Eng Mg is required prior tompbpurarnT eoncrete 4 'TT- ',e.■ 'it WriAg4:,,,7I. .'SEW8.4pitptINNI. 4 V r;40 iii4 1 4 ,1 N:, 14 0:".!' PW ',1.5.1ETkS9Fr,11 USE EE Chaf'qed Pa-! tl '.•;it -..Creditect 't toq■■.4.; 4 `-',#Tot ,..4 teini .r 50 00 00 k T, Olie7e oba 1 '09 CK.i.j loilisi 7 00 4214 1 1 a l 124-24 .50 00 `dranf;11 Thbal: 12474 50 GO connection 1-nbpe.sq.%iktiv1 re d by 1 •I 21THY OP PORT ANIGE4LE REj 70. j"?.9 Port&neP W98362 'EV,44 not Thetnantnag. any tri 44. ,AM A Page ieurAo0,17-- tt.• :t) 00 A 4 4rr 79A'40' Due ei {KN. 4,0 TA, errrut. 6 •41. Iii,- 4,1- -.2." r• .4: it, 41, _Azve.4 7 beeiTmle:s...044 void if t ofizid is not c-oiiymnce t 6 '8 1180 days f a pspp ,Q.,:1: ays a er t e won Otilmekc.""edk;,o„,,r-,;ftstuved.-4p,speptions,,, a. i.;.:' t; b'fi.... ...c 44 raltiiitilroatoh.i liete.,,iiy II ati-$ate TeTad:glidliareirin61110, gpfilkation it of recognize andardilaws an&ordinances ,SWeitfitet4is wippy At .i• 13' /411:;:t .:1,/ „:,.*1 1 ofgrii,st:perralit79100 es:10e tp;:gly$90rio a ALIthortzdagenit,t, Date SighitAreAcite, Wner-OPOlype" AO, bu tilde 4-1 Call 1,(6:(1A411-4655 for fire inspections. Please provide a minimum 24-hour notice It is unlawful to cor insulate or corike0atiy work before inspected and accepted. Post permit in a conspicuous lOtation. r FIRE'S thici hydrostatically tested UndergitOuri piping flushed Interof pp ly tested I .1 KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE Inspection Type ER Inteo,OF Vying inspection Dry systertair tested at 40 psi (24'hours) Sprinkler foil IFIIRM Rough-in. inspection Alarm LP-GAS Undergatp41ping inspection/pressure test AbciAglorn;piping inspection/pressure test L'arixi0Ontather),Inspection 1.kialK" AppharicehnSOCtion LP '3? 7 gdsfrfill,, FIRE PERMIT INSPECTION RECORD 8107 MCI. usibusie 416ID'STORAGE TANK (UST) ABANDONMENT I Rern'oVit Pfl'afrnable/combUstible liquids Tarik4ppre'prrately abandoned 0.Lek UST4haytd_ornent final PERMIT OTHER (specify) permit finA GENERAL COMMENTS Date Passed I Comments Completed Sytontractor- Test #1 Piping pressure test Time initiated'. Test #2' Piping pressure test Time initiated ',71Tre...;7Gr• V 4 psi psi 1 :2V1 5 0: Application Number Application pin number Property Address ASSESSOR PARCEL NUMBER Tenant nbr name Application type description Subdivision Name Property Use Property Zoning Application valuation Owner NEWALL ENTERPRISES 903 STRAIT VIEW DR PORT ANGELES Permit Additional desc Permit pin number Sub Contractor Permit Fee Issue Date Expiration Date Qty 1 00 3 00 Unit Charge 40 0000 11 0000 WA 983628476 COMMENTS /ACTION NEEDED CITY OF PORT. ANGELES PUBLIC WORKS ELECTRICAL DIVISION 321 EAST 5TH STREET PORT ANGELES, WA 98362 06 00000099 034541 1809 MELODY LN 06 30 14 6 2 0440 0000 HECKMAN CONDOMINIUM RES NEW MULTI 5+ FAMILY RESIDENTIAL HIGH DENSITY 913115 Contractor Date 3/19/07 VISION BUILDERS INC 3705 CRITCHFIELD RD PORT ANGELES WA 98363 (360) 452 1186 Structure Information 000 000 6 UNIT CONDOMINIUM Other struct info TOTAL LOT COVERAGE HARD SURFACE AREA NUMBER OF STORIES LOT SIZE TOTAL LOT COVERAGE NUMBER OF UNITS ELECTRICAL NEW RESIDENTIAL HI TECH/ FA SYSTEM 97253 HI TECH SECURITY INC 73 00 Plan Check Fee 3/19/07 Valuation 9/15/07 Per EL LOW VOLT SYS =2500 SQFT EL LOW VOLT SYS >2500 SQFT 1 Special Notes and Comments Owner is responsible for ongoing fire alarm system inspection and maintenance per the current addition of NFPA 72 03/09/2007 02 01 PM KDUBUC 1) The plans do not show alarm points for the sprinkler system monitoring System shall monitor flow switches ab well as tamper devices on the riser and the PIV 2) The smoke detector in the sprinkler riser room is not required 3) The door to the room containing the FACP must be labeled on the exterior with the letters FACP This project will require seperate permit and fire sprinkler plans for review This project will require a seperate permit and fire alarm plans for review A minimum 2A 10BC fire exinguisher is required Extinguishers must be mounted with the top no more than 5 off the floor Suggested extinguisher placement is adjacent to an exit 02/03/2006 10 40 AM KDUBUC X28 00 3 00 13300 00 3727 00 6 00 00 0 Extension 40 00 33 00 DI I'CH ROUGH -IN COVER SERV ICE FINAL GENERAL COMMENTS: ELECTRICAL PERMIT INSPECTION RECORD CALL 417 -4735 FOR ELECTRICAL INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER INSULATE OR CONCEAL ANY WORK BEFORE IT IS INSPECTED AND ACCEPTED. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED COMMENTS YES NO PW -I 102.15 W96) Application Number Application pin number Special Notes and Comments Other Fees Fee summary Permit Fee Total Plan Check Total Other Fee Total Grand Total Charged 73 00 00 12424 50 12497 50 COMMENTS /ACTION NEEDED CITY OF PORT ANGELES PUBLIC WORKS ELECTRICAL DIVISION 321 EAST 5TH STREET PORT ANGELES, WA 98362 06 00000099 034541 A KNOX locking keybox will be required Contact the Fire Department at 417 4653 for order and location information 02/03/2006 10 40 AM KDUBUC Doors to rooms containing fire sprinkler riser and fire alarm control panel must be labeled 02/09/2006 12 28 PM SROBERDS The proposal is for a 6 unit condominium in the RHD for total lot coverage of,28% No land use issues are noted Electrical load calculations and elctrical permits are required Transformer installation at customer s expense A cost estimate will be prepared after load requirements are provided 02/01/2006 01 21 PM GMCLAIN Sanitary sewer connection inspection is required by Public Works prior to back fill of ditch 24 hour advance notice is required Each unit will have its own water meter 'and seperate irragation meter with back flow pervention 6 pvc water main is along Melody Lane 6 fire line will require a seperate tap on water main Construct driveway and Sidewalks to City Standards No concrete with exposed aggregate allowed in the City road right of way An inspection by Public Works Engineering is required prior to prouring concrete SEWER SYSTEM DELV CHARGE STATE SURCHARGE PW WATER SYSTEM USE FEE Paid Credited 73 00 00 12424 50 12497 50 00 00 00 00 Page 2 Date 3/19/07 5220 00 4 50 7200 00 Due 00 00 00 00 CALL 417 -4735 FOR ELECTRICAL INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE IT IS INSPECTED AND ACCEPTED. DU CH CH M I I ROUGH -IN COVEk I I SERVIC I I FINAL V°"." I I I I I I I I I GENERAL COMMENTS: ELECTRICAL PERMIT INSPECTION RECORD KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED YES I NO COMMENTS PW- 1102.13I46I Application Number 06 00000099 Application pin number 034541 Property Address 1809 MELODY LN ASSESSOR PARCEL NUMBER 06 30 14 6 2 0440 0000 Tenant nbr name HECKMAN CONDOMINIUM Application type description RES NEW MULTI 5+ FAMILY Subdivision Name Property Use Property Zoning RESIDENTIAL HIGH DENSITY Application valuation 913115 Owner NEWALL ENTERPRISES 903 STRAIT VIEW DR PORT ANGELES WA 983628476 Structure Information 000 000 6 UNIT Other struct info TOTAL Permit Additional desc Permit pin number Permit Fee Issue Date Expiration Date T• \Policies \1102_15 building permit inspection record05.wpd [1/4/2005] CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING DIVISION 321 EAST 5TH STREET PORT ANGELES, WA 98362 Contractor HARD SURFACE AREA NUMBER OF STORIES LOT SIZE TOTAL LOT COVERAGE NUMBER OF UNITS VISION BUILDERS INC 3705 CRITCHFIELD RD PORT ANGELES (360) 452 1186 CONDOMINIUM LOT COVERAGE FIRE ALARM SYSTEM FIRE ALARM 96701 150 00 Plan Check Fee 3/13/07 Valuation 9/09/07 Qty Unit Charge Per 1 00 100 0000 ECH FIRE INSPECTION TESTING 1 00 50 0000 ECH FIRE ALARM PLAN REVIEW Special Notes and Comments Owner is responsible for ongoing fire alarm system inspection and maintenance per the current addition of NFPA 72 03/09/2007 02 01 PM KDUBUC 1) The plans do not show alarm points for the sprinkler system monitoring System shall monitor flow switches as well as tamper devices on the riser and the PIV 2) The smoke detector in the sprinkler riser room is not required 3) The door to the room containing the FACP must be labeled on the exterior with the letters FACP This project will require seperate permit and fire sprinkler plans for review This project will require a seperate permit and fire alarm plans for review A minimum 2A 10BC fire exinguisher is required Extinguishers must be mounted with the top no more than 5 off the floor Suggested extinguisher placement is adjacent to an exit 02/03/2006 10 40 AM KDUBUC A KNOX locking keybox will be Date 3/13/07 WA 98363 28 00 1 3 00 13300 00 3727 00 6 00 00 11000 Extension 100 00 50 00 Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days if construction or work is suspended or abandoned for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last inspection I- hereby certify that -I have -read -and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of ns`ruction. 3)'30 Signature of Contractor or Authorized Agent date Signature of Owner (if owner is builder) Date CALL 417 -4815 FOR BUILDING INSPECTIONS. CALL 417 -4735 FOR ELECTRICAL INSPECTIONS. CALL 417 -4807 FOR PUBLIC WORKS UTILITIES PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE. INSPECTION TYPE DATE ACCEPTED COMMENTS YES NO FOUNDATION: FOOTINGS SHEAR WALLS WALLS FOUNDATION DRAINAGE DOWN SPOUTS PIERS POST HOLES (POLE BLDGS.) PLUMBING UNDERFLOOR /SLAB ROUGH -IN WATER LINE (METER TO BLDG) GAS LINE BACK FLOW WATER AIR SEAL WALLS CEILING FRAMING JOISTS GIRDERS SHEAR WALL/HOLD DOWNS WALLS ROOF CEILING DRYWALL (INTERIOR BRACED PANEL ONLY) T -BAR INSULATION SLAB WALL FLOOR CEILING MECHANICAL HEAT PUMP FURNACE DUCTS GAS LINE WOOD STOVE PELLET CHIMNEY COMMERCIAL HOOD DUCTS MANUFACTURED HOMES FOOTING SLAB BLOCKING HOLD DOWNS SKIRTING PLANNING DEPT SEPARATE PERMIT #'s PARKING /LIGHTING LANDSCAPING RESIDENTIAL ELECTRICAL LIGHT DEPT CONSTRUCTION R.W PW/ ENGINEERING 417 -4807 FIRE 417 -4653 1 810? 1 c4) PLANNING DEPT 417 -4750 I BUILDING 417 -4815 i \Policies\l 102 15 building permit inspection record05.wpd [1/4/2005] BUILDING PERMIT INSPECTION RECORD I I I I I I I I I I I I FINAL FINAL SEPA. ESA. SHORELINE. DATE ACCEPTED BY. DATE ACCEPTED BY. FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE DATE YES NO COMMERCIAL DATE ACCEPTED YES I NO 417 -4735 ELECTRICAL LIGHT DEPT CONSTRUCTION R.W PW ENGINEERING I FIRE DEPT I PLANNING DEPT I BUILDING Application Number Application pin number Other Fees Fee summary T• \Policies \1102_15 building permit inspection record05.wpd [1/4/2005] CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING DIVISION 321 EAST 5TH STREET PORT ANGELES, WA 98362 06 00000099 034541 Special Notes and Comments required Contact the Fire Department at 417 4653 for order and location information 02/03/2006 10 40 AM KDUBUC Doors to rooms containing fire sprinkler riser and fire alarm control panel must be labeled 02/09/2006 12 28 PM SROBERDS The proposal is for a 6 unit condominium in the RHD for total lot coverage of 28% No land use issues are noted Electrical load calculations and elctrical permits are required Transformer installation at customer s expense A cost estimate will be prepared after load requirements are provided 02/01/2006 01 21 PM GMCLAIN Sanitary sewer connection inspection is required by Public Works prior to back fill of ditch 24 hour advance notice is required Each unit will have its own water meter and seperate irragation meter with back flow pervention 6 pvc water main is along Melody Lane 6 fire line will require a seperate tap on water main Construct driveway and Sidewalks to City Standards No concrete with exposed aggregate allowed in the City road right of way An inspection by Public Works Engineering is required prior to prouring concrete SEWER SYSTEM DELV CHARGE 5220 00 STATE SURCHARGE 4 50 PW WATER SYSTEM USE FEE 7200 00 Charged Paid Credited Due Page 2 Date 3/13/07 Permit Fee Total 150 00 150 00 00 00 Plan Check Total 00 00 00 00 Other Fee Total 12424 50 12424 50 00 00 Grand Total 12574 50 12574 50 00 00 Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days if construction or work is suspended or abandoned for a period of 180 days after the work as commenced or if required inspections have not been requested within 180 days from the last inspection I hereby certify that -I have- read -and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Signature of Contractor or Authorized Agent Date Signature of Owner (if owner is builder) Date CALL 417 -4815 FOR BUILDING INSPECTIONS. CALL 417 -4735 FOR ELECTRICAL INSPECTIONS. CALL 417 -4807 FOR PUBLIC WORKS UTILITIES PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE. INSPECTION TYPE DATE ACCEPTED COMMENTS FOUNDATION: FOOTINGS SHEAR WALLS WALLS FOUNDATION DRAINAGE DOWN SPOUTS PIERS POST HOLES (POLE BLDGS.) PLUMBING UNDER FLOOR SLAB ROUGH -IN WATER LINE (METER TO BLDG) GAS LINE BACK FLOW WATER AIR SEAL WALLS CEILING FRAMING JOISTS GIRDERS SHEAR WALL/HOLD DOWNS WALLS ROOF CEILING DRYWALL (INTERIOR BRACED PANEL ONLY) T -BAR INSULATION SLAB WALL FLOOR CEILING MECHANICAL HEAT PUMP FURNACE DUCTS GAS LINE WOOD STOVE PELLET CHIMNEY COMMERCIAL HOOD DUCTS MANUFACTURED HOMES FOOTING SLAB BLOCKING HOLD DOWNS SKIRTING PLANNING DEPT SEPARATE PERMIT #'s PARKING /LIGHTING LANDSCAPING RESIDENTIAL BUILDING PERMIT INSPECTION RECORD YES I NO FINAL FINAL SEPA. ESA. SHORELINE. DATE ACCEPTED BY. DATE ACCEPTED BY. FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE DATE YES NO COMMERCIAL DATE ACCEPTED YES I NO ELECTRICAL LIGHT DEPT 417 -4735 ELECTRICAL LIGHT DEPT CONSTRUCTION R.W PW/ CONSTRUCTION R.W ENGINEERING 417 -4807 PW ENGINEERING FIRE 417 -4653 1%/01 Kin. I I I FIRE DEPT I I I PLANNING DEPT 417 -4750 I I I I PLANNING DEPT) I I I BUILDING 417 -4815 I I I BUILDING I I I r \Policies \1102_15 building permit inspection record05.wpd [1/4/2005] Project Name Heckman Condos Address 1809 Melody Lane Plan 07 -04 PORT ANGELES FIRE DEPARTMENT FIRE ALARM SYSTEM PLAN REVIEW Installer• Hi -Tech Security Date 3 9.2007 We have checked this plan and find that it conforms to the requirements of our codes and ordinances, with the following comments. 1) The plans do not show alarm points for the sprinkler system monitoring. System shall monitor flow switches as well as tamper devices on the riser and the PIV 2) The smoke detector in the sprinkler riser room is not required. 3) The door to the room containing the FACP must be labeled on the exterior with the letters "FACP" This system is monitored by an off -site central station monitoring company and the building must be equipped with a KNOX locking keybox. The following comments apply to all systems 1 All systems shall be installed per NFPA 72 2 A final field acceptance test will be conducted before final approval. The field acceptance test will be a test of ALL system components. NOTE Prior to the issuance of a Certificate of Occupancy, compliance with the above conditions must be met. Reviewed by kCL 7~''G Date 3 •g 0 7 1 n Building Department Copy Contractor/ Owner Copy Fire Department Copy Light Department Project Name: Heckman Condos Installer• Knight Fire Protection Type of System. Wet and Antifreeze Date: Additional Comments. Contractor E Building Department Fire Department PORT ANGELES FIRE DEPARTMENT 102 East Fifth Street, Port Angeles, Washington 98362 (360) 417 -4650 FAX (360) 417 -4659 Fire Sprinkler System Plan Review Address. 1809 Melody Lane Installer Telephone 417 -0505 13 3 7.2007 PAFD Permit 07 -11 We have checked this plan and find that it conforms to the requirements of the code. All systems, including underground mains, shall be installed by a state licensed and certified company Systems shall be installed per the applicable NFPA Standard. All electrical components shall be compatible with the fire alarm system. All underground piping must be inspected and hydrostatically tested by the Port Angeles Fire Department PRIOR to being covered. A witnessed flush of the underground piping is required. A design spnnlder flow test and alarm test are required for all 13R systems. Before final acceptance of the system, an inspection will be conducted to ensure that the installation complies with the applicable NFPA Standard. This 13R system will require a measured flow test and a 200 PSI pressure test for 2 hours Reviewed by Date: 3 7 0 7 13R® 13D❑ Applicant of Agent: Owner. S 01 City. Architect/En ineerL /VDP91 4 era Address: Contractor, Address: 7x79 4 PROJECT ADDRESS DA A LEGAL DESCRIPTION Lot: CLALLAM COUNTY PARCEL NUMBER. T YP OF WORK. esidential New Constr Multi- family Addition Commercial Remodel Repair Sign BRIEF DESCRIPTION OF THE PROJECT BUILDING PERMIT APPLICATION Fill out COMPLETELY and hi INK. Your application and site plan MUST BE COMPLETE to be accepted for review If you have any questions, call PERMITS (360) 417 -4815 FAX(360)417 -4711 Srtcit Re -roof Stove Move Garage Demolition Deck Other State License Block: Phone: (fit 1 Phon -.111r 4 Phone: Subdivision. ST7 SF /SF SF /SF SF /SF TOTAL VALUATION $__Z„g_74 S Zip��J�'z ZONING Phone4jror Zip •6 COMMERCIAL/RESIDENTIAL. Occupancy Group. Occupant Load. Construction Type: No. of Stories: Lot Size: Existing Sq Ft. Proposed Sq Ft. TOTAL Sq Ft. Total lot coverage PLANNING USE ONLY ESA/Wetland(s) Yes No SEPA Checklist required? Yes No Other VALUATION OF CONSTRUCTION In all cases, a valuation amount must be entered by the applicant. This figure will be reviewed and may be revised by the Building Division to comply with current fee schedules. Contact the Permit Coordinator at 417 -4815 for assistance. PLAN CHECK FEE. IF a plan check fee is due it must be submitted at the time the building permit application and construction plans are submitted. All other permit fees are due at the time of permit issuance. EXPIRATION OF PLAN REVIEW If no permit is issued within 180 days of the date of application, the application will expire. The Building Official can extend the time for action by the applicant up to 180 days upon written request by the applicant (see Section R105.3.2 of the International Building/Residential Code, 2003). No application can be extended more than once. I hereby certify that I have read and ermined this application and know the same to be true and correct. I am authorized to apply for this permit and understand fl t/it`s my responsibility to etermine what permits are required not the City's, and that must obtain such permits prior to wor:1 A T•\FOxMS\BldgPermitform.wpd Applicant: ii Date: _1442,j- 5 Q7 FOR OFFICIAL,USE 9/\1 Date Re, Q 3697/o7 Permit eNe; 77 Date Approved: Date Issued: ©-1 �O7 APPROVALS PLAN BLDG DPWU FIRE. OTHER. FIRE DEPARTMENT PLANNING DEPARTMENT PUBLIC WORKS/ENGINEERING DIVISION LIGHT DIVISION ENERGY ENGINEERING POLICE DEPARTMENT ADMINISTRATION Li CITY CLERK Li RISK MANAGEMENT FROM. PUBLIC WORKSBUILDING DIVISION RE ADDRESS <D NAME /CONTACT a PHONE 2727 PERMIT NUMBER. c/ 9 PROJECT DESCRIPTION r, NEW CONSTRUCTION Li ADDITION /ALTERNATION COMMENTS /CONDITIONS UIREVIEW/RETURN FILE PLANNING USE ONLY BUILDING PERMIT APPLICATION Fill out COMPLETELY and in INK. Your application and site plan MUST BE COMPLETE to be accepted for review If you have any questions, call PERMITS (360) 417 -4815 FAX(360)417 -4711 Applicant or Agent: r't t Sec, r v� .1.-Y\ C. Phone 4 ,5 Owner M V\ es_ �C %Mo. v Phone Address City Zip Architect/Engineer L IAA e..t' i- S P.N-A 55 gs Phone. Contractor H t Se c.., orgy State License 14ITECT� Exp I V B 09 Phone 'Sc) a 7 7 Address 7013 rro J$ 71 CityFk A 6 .2 5 Zip gc4 3 6— PROJECT ADDRESS l gO Y\e \ock LQne_ ZONING U LEGAL DESCRIPTION Lot: Block: Subdivision. CLALLAM COUNTY PARCEL NUMBER. Credit Card Holder Name: Billing Address. City. Credit Card Type VISA MC Exp. Date: TYPE OF WORK. SIZE/VALUATION Residential X New Constr. Re -roof Stove SF /SF Multr- family Addition Move Garage SF /SF g Commercial Remodel Demolition Deck SF /SF Repair Sign Other TOTAL VALUATION A I o o a BRIEF DESCRIPTION OF THE PROJECT i f 2 4 br V" t COMMERCIAL/RESIDENTIAL. Occupancy Group Occupant Load. Construction Type No of Stories. Lot Size Existing Sq Ft. Proposed Sq Ft. TOTAL Sq Ft. Total lot coverage ESA/Wetland(s) Yes No SEPA Checklist required? Yes No Other FOR OFFICIAL USE 1'1LY Date Rec. •497 Permit D(o— q Date Approved. Date Issued. APPROVALS: PLAN BLDG DPWU FIRE OTHER. VALUATION OF CONSTRUCTION In all cases, a valuation amount must be entered by the applicant. This figure will be reviewed and may be revised by the Building Division to comply with current fee schedules. Contact the Permit Coordinator at 417 -4815 for assistance. PLAN CHECK FEE IF a plan check fee is due it must be submitted at the time the building permit application and construction plans are submitted. All other permit fees are due at the time of permit issuance. EXPIRATION OF PLAN REVIEW If no permit is issued within 180 days of the date of application, the application will expire. The Building Official can extend the time for action by the applicant up to 180 days upon written request by the applicant (see Section R105.3.2 of the International Building /Residential Code, 2003) No application can be extended more than once I hereby certify that I have read and examined this application and know the same to be true and correct. I am authorized to apply for this permit and understand that it is my responsibility to determine what permits are require ,not the City's, and that 1, st obtain such permits prior to work. A TARVESS\BLDG- forms brochures \2004- Buildingpermit.wpd Applicant: Date: 3 /6. t -7 Q -P+flt� OT -Ut/ FROM. PUBLIC WORKSBUILDING DIVISION RE ADDRESS 4t NAME /CONTACT K COMMENTS /CONDITIONS FIRE DEPARTMENT PLANNING DEPARTMENT PUBLIC WORKS/ENGINEERING DIVISION LIGHT DIVISION ENERGY ENGINEERING POLICE DEPARTMENT ADMINISTRATION CITY CLERK RISK MANAGEMENT 4i,/, 4, PHONE 7 rd S' PERMIT NUMBER. .176- 9 7 PROJECT DESCRIPTION n p S, lop r 0._ NEW CONSTRUCTION ADDITION /ALTERNATION 11 REVIEW/RETURN FILE Owner Contractor CITY OF PORT ANGELES PUBLIC WORKS ELECTRICAL DIVISION 121 EAST 5TH STREET PORT ANGELES. WA 98362 Application Number 06 00000099 Date 3/01/07 Application pin number 034541 Property Address 1809 MELODY LN ASSESSOR PARCEL NUMBER 06 30 14 6 2 0440 0000 Tenant nbr name HECKMAN CONDOMINIUM Application type description RES NEW MULTI 5+ FAMILY Subdivision Name Property Use Property Zoning RESIDENTIAL HIGH DENSITY Application valuation 913115 NEWALL ENTERPRISES VISION BUILDERS INC 903 STRAIT VIEW DR 3705 CRITCHFIELD RD PORT ANGELES WA 983628476 PORT ANGELES WA 98363 (360) 452 1186 Structure Information 000 000 6 UNIT CONDOMINIUM Other struct info TOTAL LOT COVERAGE 28 00 HARD SURFACE AREA 1 NUMBER OF STORIES 3 00 LOT SIZE 13300 00 TOTAL LOT COVERAGE 3727 00 NUMBER OF UNITS 6 00 Permit ELECTRICAL NEW RESIDENTIAL Additional desc OLY EL 600 200 &6 150A Permit pin number 96172 Sub Contractor OLYMPIC ELECTRIC Permit Fee 282 00 Plan Check Fee 00 Issue Date 3/01/07 Valuation 0 Expiration Date 8/28/07 Qty Unit Charge Per Extension 7 00 22 0000 ECH EL RM 0 200 ADD SRV FEEDER 154 00 1 00 128 0000 ECH EL RM 401 600 1ST SRV FEEDER 128 00 Special Notes and Comments This project will require seperate permit and fire sprinkler plans for review This project will require a seperate permit and fire alarm plans for review A minimum 2A 10BC fire exinguisher is required Extinguishers must be mounted with the top no more than 5 off the floor Suggested extinguisher placement is adjacent to an exit 02/03/2006 10 40 AM KDUBUC A KNOX locking keybox will be required Contact the Fire Department at 417 4653 for order and location information 02/03/2006 10 40 AM KDUBUC Doors to rooms containing fire sprinkler riser and fire alarm control panel must be labeled 02/09/2006 12 28 PM SROBERDS The proposal is for a 6 unit condominium in the RHD for total lot coverage of 28% No land use issues are noted Electrical load calculations and elctrical permits are required COMMENTS /ACTION NEEDED CALL 417 -4735 FOR ELECTRICAL INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE IT IS INSPECTED AND ACCEPTED. DITCH ROUGH -IN COVER SERVICE FINAL j. GENERAL COMMENTS: t ELECTRICAL PERMIT INSPECTION RECORD KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED YES I NO I I I I I I I I I I I I I COMMENTS PW -I 102.15 (4/961 Application Number Application pin number Other Fees Fee summary Permit Fee Total Plan Check Total Other Fee Total Grand Total Charged 282 00 00 12424 50 12706 50 COMMENTS /ACTION NEEDED CITY OF PORT ANGELES PUBLIC WORKS ELECTRICAL DIVISION 321 EAST 5TH STREET PORT ANGELES. WA 98362 06 00000099 034541 Special Notes and Comments Transformer installation at customer s expense A cost estimate will be prepared after load requirements are provided 02/01/2006 01 21 PM GMCLAIN Sanitary sewer connection inspection is required by Public Works prior to back fill of ditch 24 hour advance notice is required Each unit will have its own water meter and seperate irragation meter with back flow pervention 6 pvc water main is along Melody Lane 6 fire line will require a seperate tap on water main Construct driveway and Sidewalks to City Standards No concrete with exposed aggregate allowed in the City road right of way An inspection by Public Works Engineering is required prior to prouring concrete SEWER SYSTEM DELV CHARGE STATE SURCHARGE PW WATER SYSTEM USE FEE Paid Credited 282 00 00 12424 50 12706 50 00 00 00 00 Page 2 Date 3/01/07 5220 00 4 50 7200 00 Due 00 00 00 00 CALL 417-4735 FOR ELECTRICAL INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE IT IS INSPECTED AND ACCEPTED. DITCH ROUGH IN I COVEk SERVICE FINAL M/a- 8 61 GENERAL COMMENTS: ELECTRICAL PERMIT INSPECTION RECORD KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED YES I NO COMMENTS PW- 1102.15 (4/961 PREPARED 2/14/07 9 04 39 INSPECTION TICKET PAGE 2 CITY OF PORT ANGELES INSPECTOR JAMES L LIERLY DATE 2/14/07 ADDRESS 1809 MELODY LN SUBDIV TENANT NBR BECKMAN CONDOMINIUM CONTRACTOR VISION BUILDERS INC PHONE (360) 452 1186 OWNER NEWALL ENTERPRISES PHONE PARCEL 06 30 14 6 2 0440 0000 APPL NUMBER 06 00000099 RES NEW MULTI 5+ FAMILY REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BL9 02 2/06/07 PB BUILDING SHEARWALL 2/06/07 AP 02/06/2007 08 37 AM PERMITS pat 461 5278 02/06/2007 04 01 PM PBARTHOL EAST END OF BLDG 2ND AND 3RD FLOOR SHEARWALL OK BL9 03 2/09/07 JLL BUILDING SHEARWALL 2/09/07 AP 02/08/2007 02 55 PM PERMITS PAT 461 9169 02/09/2007 04 33 PM JLIERLY w and sw corner/j11 BL9 04 2/14/07 JL BUILDING SHEARWALL 02/13/2007 01 23 PM PERM TS 461 5278 COMMENTS AND NOTES call first J A�� A� C_ /y M Gi�� ✓F J �JZ�I 11� PREPARED 2/09/07 9 52 21 INSPECTION TICKET PAGE 4 CITY OF PORT ANGELES INSPECTOR JAMES L LIERLY DATE 2/09/07 ADDRESS 1809 MELODY LN SUBDIV TENANT NBR HECKMAN CONDOMINIUM CONTRACTOR VISION BUILDERS INC PHONE (360) 452 1186 OWNER NEWALL ENTERPRISES PHONE PARCEL 06 30 14 6 2 0440 0000 APPL NUMBER 06 00000099 RES NEW MULTI 5+ FAMILY REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BL9 02 2/06/07 PB 2/06/07 AP BUILDING SHEARWALL 02/06/2007 08 37 AM PERMITS pat 461 5278 02/06/2007 04 01 PM PBARTHOL EAST END OF BLDG 2ND AND 3RD FLOOR SHEARWALL OK BL9 03 2/09/07 LL BUILDING SHEARWALL 0' 02/08/2007 02 55 PM PERMITS 1-"") PAT 461 9169 COMMENTS AND NOTES S ti) C �r�e� PREPARED 2/06/07 9 09 01 INSPECTION TICKET CITY OF PORT ANGELES INSPECTOR JAMES L LIERLY ADDRESS 1809 MELODY LN SUBDIV TENANT NBR HECKMAN CONDOMINIUM CONTRACTOR VISION BUILDERS INC PHONE (360) 452 1186 OWNER NEWALL ENTERPRISES PHONE PARCEL 06 30 14 6 2 0440 0000 APPL NUMBER 06 00000099 RES NEW MULTI 5+ FAMILY REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BL9 02 2/06/07 BUILDING SHEARWALL 02/06/2007 08 37 AM PERMITS pat 461 5278 COMMENTS AND NOTES C4-sr g4!) N9 7 Sp i00r2 dG�- PAGE 2 DATE 2/06/07 PREPARED 12/08/06 9 52 51 INSPECTION TICKET PAGE 1 CITY OF PORT ANGELES INSPECTOR JAMES L LIERLY DATE 12/08/06 ADDRESS 1809 MELODY LN SUBDIV TENANT NBR HECKMAN CONDOMINIUM CONTRACTOR VISION BUILDERS INC PHONE (360) 452 1186 OWNER NEWALL ENTERPRISES PHONE PARCEL 06 30 14 6 2 0440 0000 APPL NUMBER 06 00000099 RES NEW MULTI 5+ FAMILY PERMIT BPC 00 BUILDING PERMIT COMMERCIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BL1 01 6/09/06 JLL 6/09/06 DA BUILDING FOUNDATION FOOTING TIME 13 00 CHAD 360 808 5775 06/08/2006 02 48 PM DYASUMUR 06/09/2006 04 08 PM PBARTHOL Id property lines so set back can be verified BL1 02 6/12/06 JLL BUILDING FOUNDATION FOOTING TIME 13 00 6/13/06 AP CHAD 808 5775 AM INSPECTION 06/09/2006 01 32 PM DYASUMUR 06/13/2006 08 37 AM JLIERLY 20 ground BL2 01 6/28/06 JLL BUILDING FOUNDATION WALL TIME 13 00 6/28/06 AP CHAD 360 808 5775 06/27/2006 08 53 AM DYASUMUR 06/28/2006 04 33 PM JLIERLY partial east side/j11 BL2 02 7/18/06 JLL BUILDING FOUNDATION WALL TIME 13 00 7/18/06 AP CHAD 808 5775 07/17/2006 07 59 AM DYASUMUR 07/18/2006 04 31 PM PBARTHOL NEED TO SEND COPIES OF ALL KRAZAN REPORTS TO THE BUILDING DEPARTMENT BLRI 01 8/04/06 JLL BUILDING REBAR INSPECTION TIME 13 00 8/04/06 AP DEREK 452 1186 08/03/2006 03 41 PM DYASUMUR 08/04/2006 04 15 PM PBARTHOL SLAB STEEL FOR ALL EXCEPT CENTER SECTION BLM 01 8/08/06 JLL BUILDING FOUNDATION MONO SLAB TIME 13 00 8/08/06 AP 08/07/2006 04 10 PM PERMITS CHAD 360 808 5775 AFTERNOON 08/08/2006 04 25 PM JLIERLY BLRI 02 8/30/06 JLL BUILDING REBAR INSPECTION TIME 13 00 8/31/06 AP 08/29/2006 10 21 AM DYASUMUR DERRICK 670 9270 08/31/2006 10 42 AM PBARTHOL 1st floor n 1/3 pan deck rebar krazan inspection ok BLRI 03 9/15/06 JLL BUILDING REBAR INSPECTION TIME 13 00 9/15/06 DA CHAD 808 5775 09/14/2006 08 58 AM DYASUMUR 09/15/2006 05 03 PM PBARTHOL not all rebar 3/4 off deck BUILDING CONCRETE FLOOR TIME 13 00 craig 461 3985 09/18/2006 12 10 PM PBARTHOL ok per krazan inspection pour was 3/4 done when i arrived pb BL9 01 12/08/06 R,L BUILDING SHEARWALL 12/08/2006 09 52 AM JLIERLY 1st flr shear wall only/j11 BCF 01 9/18/06 JLL 9/18/06 AP COMMENTS AND NOTES KraZan ASSOCIATES, INC Vision Builders Greg Hopfs (email) 3705 South Critchfield Road Port Angeles, WA 98362 PS pm Enclosures GEOTECHNICAL ENGINEERING e ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING INSPECTION November 3 2006 KA Project No 106 -06100 RE. Melody Lane 6 -Plex Condominiums Dear Mr Hopfs. In accordance with your request and authorization, the following test data are presented on the following reports, which are enclosed. September 18 Concrete Report No 27170 Referenced concrete reports and compressive strength data will be mailed following 28 -day tests, if applicable If you have any questions, or if we can be of further assistance, please do not hesitate to contact our office. Respectfully submitted, Penn Seely Laboratory Manager Peninsula Division Cc: Edward Johnson Associates Ed Johnson (email) City of Port Angeles With Offices Serving The Western United States 20714 State Hwy 305 NE, Suite 3C Poulsbo, Washington 98370 (360) 598 -2126 Fax. (360) 598 -2127 v November 3, 2006 Vision Builders, Inc. Mr Craig Heckman 3705 Cntchfield Road Port Angeles, WA 98362 RE 1809 Melody Lane Lots 2, 3, and 4 of condominium development Dear Craig: In response to our discussion m the office regarding continued site development of property located in the 1800 Block of Melody Lane, specifically Lots 2, 3, and 4 of the condominium development, significant thought and research of your request to establish the curb height as the base factor for development has occurred. You stated that you need to raise the existing property base because of a lack of fall to the stormwater basin at the northeast corner of Melody Lane and Melody Circle. However, you did not submit engmeenng calculations to support this belief. As you know, the defimtion of height is very specific in the City's Zoning Ordinance with reference to "pre alteration" grade, which, at this time, is very easy to establish as no development has occurred. You were asked to establish that grade following approval of the development on Lot 1, and I hope that by now that has been accomplished. Until engmeenng mformation is submitted that establishes a need to raise the level of the site from its natural state (pre alteration grade), the pre alteration grade level must remain the original ground level. I know that this is not the answer you were hoping for, but assure you that once submitted, supporting information will be quickly reviewed in order to keep your projects on course. W A S H I N G T O N U S A Community Economic Development Department Sue Roberds Planning Manager ORT ANGELES Phone 360 -417 -4750 Fax: 360- 417 -4711 Website www cityofpa us Email smartgrowth @cityofpa us 321 East Fifth Street P 0 Box 1150 Port Angeles WA 98362 -0217 LE- ice. (3% 'opC 3(s s3 0-- Top e 3�5 4-5 C� scot DS L_ oT L EA is179-3e--- ?P5 F°sf-D F F 34,7_ 99 FF Rai &b r' 3 49 GYP =a V /2 f D'- TE'mtv'. 1E 3U•e �ooTr brJ To pcuM1$ 7 ot a Co r 31o 5 53 3(04• SZ M €L-Sa L-N LoT Cap Lut.•3 Sl Z? Sw..13 3co5 70-81) Topcor 3(es s3 365 53 re y tel z o RI ,oh a' B M Top etSRg 3bS 45 3(05 S. 4z_ S cat 41 Z'F D_-T oh1 1E 3!d 3W05 L_oT 2. '045 vosEP FF pco A NIA PA TheeuM1F3 dm 'Tb 31X 5 53 4 5l M E_L L FF LOT 3 'LLB 3 A-c /h3 b 24ti Cud co)03 31 z'7 2onn L' Rtx�s r�1 October 2, 2006 Vision Builders, Inc Mr Craig Heckman 3705 Cntchfield Road Port Angeles, WA 98362 Re 1809 Melody Lane 6 unit condomuuum Dear Craig: Thank you for your prompt response and supporting information relative to height concerns with the 6 unit condominium project at 1809 Melody Lane. I appreciated your attitude regarding the issues and your willingness to follow up and provide the needed documentation m a timely manner As you know, Eric Walrath and Roger Vess of the City's Public Works and Utilities Department worked with your employee on site to venfy the elevations that you provided. We will work with those elevations as being the "pre alteration" grade for the project. That information and joist redesign will bnng the structure into compliance with the 35 -foot height maximum for the underlying zone. One note I don't believe we have yet received engineering for the redesign. Dunng your visit to the office, we discussed that a pre alteration grade stake must be placed on the adjacent lot and verified prior to any prep grading work to avoid any possible confusion in the development of the east three lots. There may be issues that have to be worked through, such as storm or sewer given the below street grade. These issues should be brought to light early in the development process, but it is imperative that the pre alteration grade be established early on to avoid violation of development standards that may result in a needed redesign. If you should ever have any questions, please don't hesitate to contact this office or Public Works and Utilities. We look forward to working with you on this and future projects. incerely, ORT NGELES W A S H I N G T O N U S A Community Economic Development Department Sue Roberds Planning Manager Phone 360- 417 -4750 Fax 360- 417 -4711 Website www cityofpa.us Email smartgrowth @cityofpa.us 321 East Fifth Street P 0 Box 1150 Port Angeles WA 98362 -0217 September 22, 2006 VIA HAND DELIVERY Board of Adjustment c/o Becky Upton, City Clerk City of Port Angeles 321 East Fifth Street Port Angeles, WA 98362 -0217 Dear Ms. Upton. The Interpretation is erroneous for the following reasons. t. SEP 2 2 VG B•U N'C. 3705 Cntchfield Rd Port Angeles, WA 98363 Office 360 -452 1186 Fax 360- 417 -6944 Email visionbuildersinc @olypen.com RE. Petition for Review Under Port Angeles City Code 2.52.070 Interpretation of Planning Manager dated September 12, 2006 1809 Melody Lane, Port Angeles, Washington Application No. 06 -99• Application PIN No. 34541 ;ITY OF PORT ANGELES CITY CLERK The undersigned applicant and permit holder hereby appeals to the Board of Adjustment under PACC 2.52.070 the interpretation of PACC 17 08.045 by the City of Port Angeles Planning Manager Sue Roberds, as set forth in the letter dated September 12, 2006 from Ms. Roberds to Jim and Craig Heckman of Vision Builders, Inc. a copy of which is attached hereto (the `Interpretation 1 Because of man-made changes to the site elevation over the past few years, and because of the absence of adequate records to establish the site elevation as of the date of the building permit application, it is extremely difficult to establish the existing pre alteration grade. 2. There is no substantial evidence of which the undersigned is aware that the proposed building height would violate any provision of the Port Angeles City Code. 3 The Land Use Petition Act, RCW Chapter 36.70C, and the doctrine of finality in land use decisions do not allow the reconsideration of the building permit decision at this time. Under LUPA, the question whether or not a building permit conforms to applicable development standards may not be raised unless it is raised within 21 days of the date of the building permit decision. The building permit was issued on March 21 2006 Construction under the building permit commenced shortly thereafter Under RCW 36 70C.020(1), the building permit is `land use decision, and under RCW 36 70C.040(3), an appeal of the building permit may not be brought more than 21 days after the date of the decision. The date of the decision is, at the latest, the date construction commenced, the date on which affected persons had actual notice that a decision had been made. Many more than 21 days have passed since that date. The Washington Supreme Court decided in the case of Nykriem vs. Chelan County 146 Wn. 2d 904 53 P.3d 1 (2002), that a local government may not challenge even its own land use decision more than 21 days after the date of a land use decision (in that case, Chelan County was prevented from undoing a boundary line adjustment it had approved more than 21 days earlier). The Court in Nykriem decided that it was unfair to allow local governments to change their decisions after others had relied upon them. As amici curiae point out, if this court allows local government to rescind a previous land use approval without concern of fmality innocent property owners relying on a county's land use decision will be subject to change in policy whenever a new County Planning Director disagrees with a decision of the predecessor director They also assert that land use decisions from this court emphasize the need for property owners to rely on an agency's determinations with reasonable certainty The Nykriem decision, which is based on LUPA and the doctrine of finality prevents the City of Port Angeles from lawfully reconsidering the approved building permit more than 21 days after permit issuance and commencement of construction. The Interpretation should be rescinded and vacated. The names and mailing addresses of the aggrieved parties are as follows: Jim and Lea Heckman 604 S Ennis Port Angeles WA 98362 Property Owner Vision Builders, Inc. 3705 Critchfield Rd Port Angeles WA 98363 Contractor for Project The names and mailing addresses of the attorneys for the aggrieved parties are as follows: The undersigned is working in good faith with the Planning Manager to resolve these issues as soon as possible. If they are resolved to the satisfaction of the Planning Manager and the undersigned, then the undersigned will withdraw this petition for review Thank you for your consideration. Sincerely yours, Vision Build Inc. Craig He Enclosure. Copy of Interpretation cc: Greg Richardson Marco de Sa e Silva Greg Richardson Attorney at Law PO Box 2029 Port Angeles WA 98362 Attorney for Owner and Contractor W A S H I N G T O N Community Economic Development Departmenr September 22, 2006 Vision Builders, Inc Mr Craig Heckman 3705 Cntchfield Road Port Angeles, WA 98362 Re 1809 Melody Lane 6 unit condominium Dear Craig: ORT ANGELES S A T Thank you for your letter received September 21 2006 with regard to the building height issue conveyed to you in my letter of September 12, 2006 Following our on -site meeting on Monday September 18, 2006, it was agreed that you would be working to reduce the ceiling height within the three story structure to accommodate the discrepancy m building height of some 28" The revised elevation drawing received September 21, 2006, seems to identify revisions to the floor joist and building facade which reduce the height of the structure some 14" and indicates building elevations for the site which bring the final height of the structure to 35'2" above curb height. You indicated that revised plans are being prepared m support of the revisions identified in the elevation drawmg submitted for review September 21, 2006 Please be aware that those revisions are not approved by this letter The elevations identified in your revised drawing will be checked by a City employee early dunng the week of September 25, 2006 If discrepancy is found, you will be notified immediately Unless a discrepancy is found, or engmeering is not submitted to justify the revision you proposed, it is the City's position that the height issue has been satisfactonly addressed. Please be sure to submit the revised engmeenng and site drawings at the earhest opportunity for review If you have any questions with any of this information, please don't hesitate to contact this Department. Sincerely, Sue Roberds Planning Manager cc City Manager Jim Lierly, Building Inspector Phone 360- 417 -4750 Fax: 360- 417 -4711 Website www cityofpa.us Email smartgrowth @cityofpa us 321 East Fifth Street P 0 Box 1150 Port Angeles WA 98362 -0217 Sep 20 06 07 42p greg richardson c2 s-evC' +-c-4\ `LJu o.. care September 20, 2006 By Facsimile 360 417 4711 Sue Roberds Planning Manager Community Economic Development Department City of Port Angeles 321 East 5 St. PO Box 1 150 Port Angeles WA 98362 Re: 1809 Melody Lane 6 unit condominium Building Permit #06 -99 Dear Sue: Craig Heckman S B.U 3705 Ciitchfield Rd Port Angeles, WA 98363 Office 360 -452 1186 Fax 360-417-6944 Email visionbuildersinc @olypen.com 360 4571669 p 1 PN'C. SEP 2 1 2006 CITY OF PORT ANGELES Dept. of Community Development 1 am writing to thank you for your time the past few days, in which you and I have discussed the potential resolution of the building height issue raised in your letter to me dated September 12, 2006 As you know I am agreeable to your proposed resolution that the building height for all buildings in this project be measured from the average elevation of the adjacent curbs. I understand that you and 1 will continue to discuss the issue and will try to resolve it as quickly as possible. I understand that your letter to me is an informal notice of your concern about the building height, not a formal land use decision, and that I do not need to appeal it to anyone in order to preserve my rights to the event that we do not resolve the issue amicably Will you confirm that understanding to me by return letter by this Friday September 22. Sue, I have a proposal to resolve these issues which I would like to discuss with you tomorrow morning. I will give you a call. Thank you very much for your assistance. Sincerely yours, VISION BUILDERS, INC. Krazan Associates, Inc. 20714 State Hwy 305 N E Suite 3C Poulsbo WA 98370 (360)- 598 -2126 Project No. 106 -06100 Cyl. Code P11221 Pour Date 9/18/2006 Report No. 27170 Weather OVERCAST Jurisdiction CITY OF PORT ANGELES Permit No. 06- 00000099 Project MELODY LANE 6 -PLEX Engineer Location PORT ANGELES WA Architect Client VISION BUILDERS Contractor VISION BUILDERS Field Data Site Mix Reported Batch Data Supplier ANGELES Plant No. 01 Cement Type I I I Concrete X Mortar Grout Flex Beams Design Actual X Prisms Grouted Ungrouted Other Mix No. Conc. Air Cem. lbs. 614 4 Temp. Temp. Unit F Ash lbs. Time Truck Ticket Air Slump (F) (F) Wt. 0930 A59 14221 5 5 4 25 76 56 C. agg. lbs. 1830 0 Placement Area Footings Walls Columns Grade Beams Slab /Deck X Slab Pilings Other Grids 1ST FLOOR DECK, SE CORNER Remarks Inspector JIM GIBBONS Reviewed By -6 Laboratory Data Design Strength 4000 Codes for Break Types. 1 Cone 2. Cone Split 03101 Rev 1 Effective Date 11/15/02 C. agg. lbs. 2 C. agg. lbs. 3 Sand lbs. 1212 9 Water 208 3 Admixture 2 1 Other 54 8 Air Ent. (oz/cwt) 41 7 Water Added on 5 Job (gals.) Items Inspected Conforming Non Conforming Date Specimens Recd. 9/19/06 Cyl. Test Dia Length Max. Comp. Tested Break Code Date Age Dim. Area Load Str (psi) Set By Type P11221 9/25/2006 7 4X8 12 57 45285 3 600 TMA 1 P11221 10/2/2006 14 4X8 12 54 54645 4 360 TMA 3 P11221 10/16/2006 28 4X8 12 55 62880 5 010 TMA 4 P11221 10/16/2006 28 4X8 12 55 62265 4 960 TMA 3 P11221 P11221 P11221 Test Results P11221 Conforming Remarks FR #70255 Non- Conforming Results Reviewed By Cir j Date Reviewed OC. Test Method ASTM C39 x C -1231 >C Other Compressive Flexural 3 Cone Shear 4 Shear 5 Columnar (Split) PREPARED 9/18/06 11 45 49 INSPECTION TICKET PAGE 10 CITY OF PORT ANGELES INSPECTOR JAMES L LIERLY DATE 9/18/06 ADDRESS 1809 MELODY LN SUBDIV TENANT NBR HECKMAN CONDOMINIUM CONTRACTOR VISION BUILDERS INC PHONE OWNER NEWALL ENTERPRISES PHONE PARCEL 06 30 14 6 2 0440 0000 APPL NUMBER 06 00000099 RES NEW MULTI 5+ FAMILY PERMIT BPC 00 BUILDING PERMIT COMMERCIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BL1 01 6/09/06 JLL BUILDING FOUNDATION FOOTING TIME 13 00 6/09/06 DA CHAD 360 808 5775 06/08/2006 02 48 PM DYASUMUR 06/09/2006 04 08 PM PBARTHOL Id property lines so set back can be verified BL1 02 6/12/06 JLL BUILDING FOUNDATION FOOTING TIME 13 00 6/13/06 AP CHAD 808 5775 AM INSPECTION 06/09/2006 01 32 PM DYASUMUR 06/13/2006 08 37 AM JLIERLY 20 ground BL2 01 6/28/06 JLL BUILDING FOUNDATION WALL TIME 13 00 6/28/06 AP CHAD 360 808 5775 06/27/2006 08 53 AM DYASUMUR 06/28/2006 04 33 PM JLIERLY partial east side/j11 BL2 02 7/18/06 JLL BUILDING FOUNDATION WALL TIME 13 00 7/18/06 AP CHAD 808 5775 07/17/2006 07 59 AM DYASUMUR 07/18/2006 04 31 PM PBARTHOL NEED TO SEND COPIES OF ALL KRAZAN REPORTS TO THE BUILDING DEPARTMENT BLRI 01 8/04/06 JLL BUILDING REBAR INSPECTION TIME 13 00 8/04/06 AP DEREK 452 1186 08/03/2006 03 41 PM DYASUMUR 08/04/2006 04 15 PM PBARTHOL SLAB STEEL FOR ALL EXCEPT CENTER SECTION BLM 01 8/08/06 JLL BUILDING FOUNDATION MONO SLAB TIME 13 00 8/08/06 AP 08/07/2006 04 10 PM PERMITS CHAD 360 808 5775 AFTERNOON 08/08/2006 04 25 PM JLIERLY BLRI 02 8/30/06 JLL BUILDING REBAR INSPECTION TIME 13 00 8/31/06 AP 08/29/2006 10 21 AM DYASUMUR DERRICK 670 9270 08/31/2006 10 42 AM PBARTHOL 1st floor n 1/3 pan deck rebar krazan inspection ok BLRI 03 9/15/06 JLL BUILDING REBAR INSPECTION TIME 13 00 9/15/06 DA CHAD 808 5775 09/14/2006 08 58 AM DYASUMUR 09/15/2006 05 03 PM PBARTHOL not all rebar 3/4 off deck BCE 01 9/18/06 JLL BUILDING CONCRETE FLOOR TIME 13 00 A d� i craig 461 3985 6Cc o COMMENTS AND NOTES l ypf j va (360) 452 1186 LINDBERG SIVIITH A R C H I T E C T S September 15, 2006 Ms. Sue Roberds City of Port Angeles 321 East Fifth Street, PO Box 1150 Port Angeles. WA 98362 -0217 Dear Sue, This letter is not related in any way to Mr Heckman s response However, I feel compelled to clarify an incorrect statement in the first paragraph of you letter Your statement -that Building Inspector Jim Lierly met with me at the site to explain that the approved condominium development will exceed the maximum 35' height limitation is somewhat mis- leading. SinLere y LINDBERG SMITH ARCHTITECTS Bill Cre•'n 319 south peabody suite b port angeles wa. 98362 360 452.6116 fax 360 452 7064 email contact @lindarch.com www.lindarch.com RECEH SEP 182006 CITY OF PORT ANGELES Dept. of Community Development A e are in receipt of a copy of the letter dated September 12, 2006, sent to the Heckmans regarding the height issue of their condominium structure currently under construction on Melody Lane Mr Craig Heckman is currently working to address the issues presented in your letter and I presume his response will be delivered in compliance with the time specified. I met with Jim Lierly along with Pat Bartholick and a gentleman named Scott from the Planning Department (I apologize for forgetting Scott's last name) During that meeting we discussed the height issue and the placement of the building. The discussion focused on the determination of height as found in the International Building Code and concluded that thefe was really not a problem with the construction. At the conclusion of the discussion, I left the site with the understanding that there was not a problem and relayed that information to Mr Heckman. I am not contesting the description of height determination as found in the Port Angeles Municipal Code I only want to clarify that this information was not presented at the site as stated in your letter In fact none of the representatives from the city seemed to even be aware of the requirement. I trust that this issue can be mitigated with Mr Heckman's response and the project moot_ rorward. PRE -ED 9/15/06 11 11 58 CITY OF PORT ANGELES PERMIT BPC 00 BUILDING PERMIT COMMERCIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BL1 01 6/09/06 JLL 6/09/06 DA INSPECTION TICKET INSPECTOR JAMES L LIERLY ADDRESS 1809 MELODY LN SUBDIV TENANT NBR HECKMAN CONDOMINIUM CONTRACTOR VISION BUILDERS INC PHONE (360) 452 1186 OWNER NEWALL ENTERPRISES PHONE PARCEL 06 30 14 6 2 0440 0000 APPL NUMBER 06 00000099 RES NEW MULTI 5+ FAMILY BUILDING FOUNDATION FOOTING TIME 13 00 CHAD 360 808 5775 06/08/2006 02 48 PM DYASUMUR 06/09/2006 04 08 PM PBARTHOL Id property lines so set back can be verified BL1 02 6/12/06 JLL BUILDING FOUNDATION FOOTING TIME 13 00 6/13/06 AP CHAD 808 5775 AM INSPECTION 06/09/2006 01 32 PM DYASUMUR 06/13/2006 08 37 AM JLIERLY 20 ground BL2 01 6/28/06 JLL BUILDING FOUNDATION WALL TIME 13 00 6/28/06 AP CHAD 360 808 5775 06/27/2006 08 53 AM DYASUMUR 06/28/2006 04 33 PM JLIERLY partial east side/j11 BL2 02 7/18/06 JLL BUILDING FOUNDATION WALL TIME 13 00 7/18/06 AP CHAD 808 5775 07/17/2006 07 59 AM DYASUMUR 07/18/2006 04 31 PM PBARTHOL NEED TO SEND COPIES OF ALL KRAZAN REPORTS TO THE BUILDING DEPARTMENT BLRI 01 8/04/06 JLL BUILDING REBAR INSPECTION TIME 13 00 8/04/06 AP DEREK 452 1186 08/03/2006 03 41 PM DYASUMUR 08/04/2006 04 15 PM PBARTHOL SLAB STEEL FOR ALL EXCEPT CENTER SECTION BLM 01 8/08/06 JLL BUILDING FOUNDATION MONO SLAB TIME 13 00 8/08/06 AP 08/07/2006 04 10 PM PERMITS CHAD 360 808 5775 AFTERNOON 08/08/2006 04 25 PM JLIERLY BLRI 02 8/30/06 JLL BUILDING REBAR INSPECTION TIME 13 00 8/31/06 AP 08/29/2006 10 21 AM DYASUMUR DERRICK 670 9270 08/31/2006 10 42 AM PBARTHOL 1st floor n 1/3 pan deck rebar krazan inspection ok BLRI 03 9/15/06 JLL BUILDING REBAR INSPECTION TIME 13 00 D CHAD 808 5775 09/14/2006 08 58 AM DYASUMUR PAGE 11 DATE 9/15/06 COMMENTS AND NOTES Ahr VV Cb (W- i)fd- .l. BUILDING DIVISION Job Located at /q for inspection Date CITY OF PORT ANGELES Correction Notice Inspection of your work revealed that the following is not in with the codes governing the work in this 7r Z91- Z 5 C Afe* 00 A i•goo C _4 Lk 9 7- 7 5 Pt c-ri o 4 These corrections must be made and are not to be covered until reinspection is made When corrections have been made, please call 8'5 .1n;p6Otor Division DO NOT REMOVE THIS TAG September 12, 2006 Messrs. Jim and Craig Heckman c/o Vision Builders, Inc 3705 Cntchfield Road Port Angeles, WA 98362 RE 1809 Melody Lane 6 unit condominium Dear Jim and Craig: Following a footing inspection on the above referenced project dunng the week of September 4 2006, it was determined that the existing site elevation will not accommodate the 3- story structure permitted under Building Permit #06 -99 Building Inspector Jim Lierly spoke to your architect Bill Green on site to discuss the fact that the site development/grading has raised the grade threshold such that the approved condominium development will exceed the maximum 35' height limitation in the residential zone The City's definition of height is defined m Section 17 08 045 of the Port Angeles Municipal Code as follows 'Height total distance in feet from average ground elevation at perimeter walls as determined by the final grade noted on the building plan approved by the City (as long as the final grade is not higher than the existing pre- alteration grade [emphasis added] at the center of the lot) to the top of the structure, except that-television antennae, roof mounted mechanical equipment, chimneys, and other appurtenances are exempt from height requirements. Other appurtenances include architectural features, such as ornamental cupolas, domes, and spires, not exceeding ten feet in height and diameter which are also exempt from height requirements. Alteration will need to be made in order to allow the development to be in compliance with height restrictions in the underlying residential zone No further work will, be inspected and should be considered at nsk until a resolution is presented and approved. While it is unfortunate that a misunderstanding has occurred, I am confident that you will work toward a swift resolution that will allow the project to continue Please respond within 5 working days of receipt of this letter as to what that resolution will be We look forward to heanng from you. Sincerely, ORTj NGELES Community Economic Development Department W A S H I N G T O N U S A ue Roberds Planning Manager cc Lindberg and Smith Architects T\BUILDING\Heckman0699 wpd Phone 360- 417 -4750 Fax 360- 417 -4711 Website www cityofpa.us Email smartgrowth @cityofpa us 321 East Fifth Street P 0 Box 1150 Port Angeles WA 98362 -0217 PREPARED 8/30/06 8 31 56 INSPECTION TICKET PAGE 33 CITY OF PORT ANGELES INSPECTOR JAMES L LIERLY DATE 8/30/06 ADDRESS 1809 MELODY LN SUBDIV TENANT NBR HECKMAN CONDOMINIUM CONTRACTOR VISION BUILDERS INC PHONE (360) 452 1186 OWNER NEWALL ENTERPRISES PHONE PARCEL 06 30 14 6 2 0440 0000 APPL NUMBER 06 00000099 RES NEW MULTI 5+ FAMILY PERMIT BPC 00 BUILDING PERMIT COMMERCIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BL1 01 6/09/06 JLL BUILDING FOUNDATION FOOTING TIME 13 00 6/09/06 DA CHAD 360 808 5775 06/08/2006 02 48 PM DYASUMUR 06/09/2006 04 08 PM PBARTHOL Id property lines so set back can be verified BL1 02 6/12/06 JLL BUILDING FOUNDATION FOOTING TIME 13 00 6/13/06 AP CHAD 808 5775 AM INSPECTION 06/09/2006 01 32 PM DYASUMUR 06/13/2006 08 37 AM JLIERLY 20 ground BL2 01 6/28/06 JLL BUILDING FOUNDATION WALL TIME 13 00 6/28/06 AP CHAD 360 808 5775 06/27/2006 08 53 AM DYASUMUR 06/28/2006 04 33 PM JLIERLY partial east side /j11 BL2 02 7/18/06 JLL BUILDING FOUNDATION WALL TIME 13 00 7/18/06 AP CHAD 808 5775 07/17/2006 07 59 AM DYASUMUR 07/18/2006 04 31 PM PBARTHOL NEED TO SEND COPIES OF ALL KRAZAN REPORTS TO THE BUILDING DEPARTMENT BLRI 01 8/04/06 JLL BUILDING REBAR INSPECTION TIME 13 00 8/04/06 AP DEREK 452 1186 08/03/2006 03 41 PM DYASUMUR 08/04/2006 04 15 PM PBARTHOL SLAB STEEL FOR ALL EXCEPT CENTER SECTION BLM 01 8/08/06 JLL BUILDING FOUNDATION MONO SLAB TIME 13 00 8/08/06 AP 08/07/2006 04 10 PM PERMITS CHAD 360 808 5775 AFTERNOON 08/08/2006 04 25 PM JLIERLY BLRI 02 8/30/06 JLL BUILDING REBAR INSPECTION TIME 13 00 08/29/2006 10 21 AM DYASUMUR n DERRICK 670 9270 l�c 7." COMMENTS AND NOTES coo r e U J 'en-10 bed /(,P9 L41 -.1./ /415P, ct ote, PREPARED 8/08/06 11 05 20 INSPECTION TICKET PAGE 7 CITY OF PORT ANGELES INSPECTOR JAMES L LIERLY DATE 8/08/06 ADDRESS 1809 MELODY LN SUBDIV TENANT NBR HECKMAN CONDOMINIUM CONTRACTOR VISION BUILDERS INC PHONE (360) 452 1186 OWNER NEWALL ENTERPRISES PHONE PARCEL 06 30 14 6 2 0440 0000 APPL NUMBER 06 00000099 RES NEW MULTI 5+ FAMILY PERMIT BPC 00 BUILDING PERMIT COMMERCIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BL1 01 6/09/06 JLL BUILDING FOUNDATION FOOTING TIME 13 00 6/09/06 DA CHAD 360 808 5775 06/08/2006 02 48 PM DYASUMUR 06/09/2006 04 08 PM PBARTHOL Id property lines so set back can be verified BL1 02 6/12/06 JLL BUILDING FOUNDATION FOOTING TIME 13 00 6/13/06 AP CHAD 808 5775 AM INSPECTION 06/09/2006 01 32 PM DYASUMUR 06/13/2006 08 37 AM JLIERLY 20 ground BL2 01 6/28/06 JLL BUILDING FOUNDATION WALL TIME 13 00 6/28/06 AP CHAD 360 808 5775 06/27/2006 08 53 AM DYASUMUR 06/28/2006 04 33 PM JLIERLY partial east side/j11 BL2 02 7/18/06 JLL BUILDING FOUNDATION WALL TIME 13 00 7/18/06 AP CHAD 808 5775 07/17/2006 07 59 AM DYASUMUR 07/18/2006 04 31 PM PBARTHOL NEED TO SEND COPIES OF ALL KRAZAN REPORTS TO THE BUILDING DEPARTMENT BLRI 01 8/04/06 JLL BUILDING REBAR INSPECTION TIME 13 00 8/04/06 AP DEREK 452 1186 08/03/2006 03 41 PM DYASUMUR 08/04/2006 04 15 PM PBARTHOL SLAB STEEL FOR ALL EXCEPT CENTER SECTION BLM 01 8 /0gg /06 r BUILDING FOUNDATION MONO SLAB TIME 13 00 ki 08/07/2006 04 10 PM PERMITS 111 CHAD 360 808 5775 AFTERNOON COMMENTS AND NOTES CITY OF PORT ANGELES Application Number Application pin number Property Address ASSESSOR PARCEL NUMBER Tenant nbr name Application type description Subdivision Name Property Use Property Zoning Application valuation Owner NEWALL ENTERPRISES 903 STRAIT VIEW DR PORT ANGELES Permit Additional desc Permit pin number Permit Fee Issue Date Expiration Date WA 983628476 PUBLIC WORKS ELECTRICAL DIVISION 321 EAST 5TH STREET PORT ANGELES, WA 98362 06 00000099 034541 1809 MELODY LN 06 30 14 6 2 0440 0000 HECKMAN CONDOMINIUM RES NEW MULTI 5+ FAMILY RESIDENTIAL HIGH DENSITY 913115 Contractor ELECTRICAL NEW COMMERICAL Qty Unit Charge Per 1 00 36 4000 ECH EL LVT FIRST THERMOSTAT 5 00. 11 4000 ECH EL LVT ADD THERMOSTAT VISION BUILDERS INC 3705 CRITCHFIELD RD PORT ANGELES WA 98363 (360) 452 1186 Structure Information 000 000 6 UNIT CONDOMINIUM Other struct info TOTAL LOT COVERAGE 28 00 HARD SURFACE AREA 1 NUMBER OF STORIES 3 00 LOT SIZE 13300 00 TOTAL LOT COVERAGE 3727 00 NUMBER OF UNITS 6 00 73056 93 40 Plan Check Fee 3/21/06 Valuation 1/31/07 Special Notes and Comments This project will require seperate permit and fire sprinkler plans for review This project will require a seperate permit and fire alarm plans for review A minimum 2A 10BC fire exinguisher is required Extinguishers must be mounted with the top no more than 5 off the floor Suggested extinguisher placement is adjacent to an exit 02/03/2006 10 40 AM KDUBUC A KNOX locking keybox will be required Contact the Fire Department at 417 4653 for order and location information 02/03/2006 10 40 AM KDUBUC Doors to rooms containing fire sprinkler riser and fire alarm control panel must be labeled 02/09/2006 12 28 PM SROBERDS The proposal is for a 6 unit condominium in the RHD for total lot coverage of 28% No land use issues are noted Electrical load calculations and elctrical permits are required Transformer installation at customer s expense A cost COMMENTS /ACTION NEEDED Date 8/07/06 00 0 Extension 36 40 57 00 CALL 417 -4735 FOR ELECTRICAL INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE IT IS INSPECTED AND ACCEPTED. FINAL GENERAL COMMENTS: ELECTRICAL PERMIT INSPECTION RECORD KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED YES I No DITCI-1 ROUGH -IN COVER SERVICE COMMENTS PW -I 102.15 (496J Application Number Application pin number Special Notes and Comments estimate will be prepared after load requirements are provided 02/01/2006 01 21 PM GMCLAIN Sanitary sewer connection inspection is required by Public Works prior to back fill of ditch 24 hour advance notice is required Each unit will have its own water meter and seperate irragation meter with back flow pervention 6 pvc water main is along Melody Lane 6 fire line will require 5 seperate tap on water main Construct driveway and Sidewalks to City Standards No concrete with exposed aggregate allowed in the City road right of way An inspection by Public Works Engineering is required prior to prouring concrete Other Fees Fee summary COMMENTS /ACTION NEEDED CITY OF PORT ANGELES PUBLIC WORKS ELECTRICAL DIVISION 321 EAST 5TH STREET PORT ANGELES. WA 98362 06 00000099 034541 Page 2 Date 8/07/06 SEWER SYSTEM DELV CHARGE 5220 00 STATE SURCHARGE 4 50 PW WATER SYSTEM USE FEE 7200 00 Charged Paid Credited Due Permit Fee Total 93 40 93 40 00 00 Plan Check Total 00 00 00 00 Other Fee Total 12424 50 12424 50 00 00 Grand Total 12517 90 12517 90 00 00 -4 GENERAL COMMENTS: ELECTRICAL PERMIT INSPECTION RECORD CALL 4I7 -4735 FOR ELECTRICAL INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE IT IS INSPECTED AND ACCEPTED. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED YES I NO DITCH I I I ROUGH -IN COVER I I SERVICE I I I FINAL Itt 8- 07 l, L.-' I I I I I I I I I I I I I COMMENTS Pw -I 102.15 (496J PREPARED 8/04/06 8 14 25 INSPECTION TICKET PAGE 9 CITY OF PORT ANGELES INSPECTOR JAMES L LIERLY DATE 8/04/06 ADDRESS 1809 MELODY LN SUBDIV TENANT NBR HECKMAN CONDOMINIUM CONTRACTOR VISION BUILDERS INC PHONE (360) 452 1186 OWNER NEWALL ENTERPRISES PHONE PARCEL 06 30 14 6 2 0440 0000 APPL NUMBER 06 00000099 RES NEW MULTI 5+ FAMILY PERMIT BPC 00 BUILDING PERMIT COMMERCIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BL1 01 6/09/06 JLL 6/09/06 DA BUILDING FOUNDATION FOOTING TIME 13 00 CHAD 360 808 5775 06/08/2006 02 48 PM DYASUMUR 06/09/2006 04 08 PM PBARTHOL Id property lines so set back can be verified BL1 02 6/12/06 JLL BUILDING FOUNDATION FOOTING TIME 13 00 6/13/06 AP CHAD 808 5775 AM INSPECTION 06/09/2006 01 32 PM DYASUMUR 06/13/2006 08 37 AM JLIERLY 20 ground BL2 01 6/28/06 JLL BUILDING FOUNDATION WALL TIME 13 00 6/28/06 AP CHAD 360 808 5775 06/27/2006 08 53 AM DYASUMUR 06/28/2006 04 33 PM JLIERLY partial east side/j11 BL2 02 7/18/06 JLL BUILDING FOUNDATION WALL TIME 13 00 7/18/06 AP CHAD 808 5775 07/17/2006 07 59 AM DYASUMUR 07/18/2006 04 31 PM PBARTHOL NEED TO SEND COPIES OF ALL KRAZAN REPORTS TO THE BUILDING DEPARTMENT BLRI 01 8/04/06 JLL BUILDING REBAR INSPECTION TIME 13 00 DEREK 452 1186 0 08/0303 /2006 03 41 PM DYASUMUR COMMENTS AND NOTES PREPARED 7/31/06 11 15 18 INSPECTION TICKET PAGE 2 CITY OF PORT ANGELES INSPECTOR JAMES L LIERLY DATE 7/31/06 ADDRESS 1809 MELODY LN SUBDIV TENANT NBR HECKMAN CONDOMINIUM CONTRACTOR VISION BUILDERS INC PHONE (360) 452 1186 OWNER NEWALL ENTERPRISES PHONE PARCEL 06 30 14 6 2 0440 0000 APPL NUMBER 06 00000099 RES NEW MULTI 5+ FAMILY PERMIT PL 00 PLUMBING PERMIT REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS PL1 01 7/31/06 JLL PLUMBING UNDER SLAB TIME 13 00 DEREK 452 1186 7 3 l ^'`lr w 4) 07/28/2006 09 59 AM DYASUMUR -r COMMENTS AND NOTES PREPARED 7/18/06 9 58 26 INSPECTION TICKET CITY OF PORT ANGELES INSPECTOR JAMES L LIERLY ADDRESS 1809 MELODY LN SUBDIV TENANT NBR HECKMAN CONDOMINIUM CONTRACTOR VISION BUILDERS INC PHONE (360) 452 1186 OWNER NEWALL ENTERPRISES PHONE PARCEL 06 30 14 6 2 0440 0000 APPL NUMBER 06 00000099 RES NEW MULTI 5+ FAMILY PERMIT BPC 00 BUILDING PERMIT COMMERCIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BL1 01 6/09/06 JLL 6/09/06 DA BUILDING FOUNDATION FOOTING TIME 13 00 CHAD 360 808 5775 06/08/2006 02 48 PM DYASUMUR 06/09/2006 04 08 PM PBARTHOL Id property lines so set back can be verified BL1 02 6/12/06 JLL BUILDING FOUNDATION FOOTING TIME 13 00 6/13/06 AP CHAD 808 5775 AM INSPECTION 06/09/2006 01 32 PM DYASUMUR 06/13/2006 08 37 AM JLIERLY 20 ground BL2 01 6/28/06 JLL BUILDING FOUNDATION WALL TIME 13 00 6/28/06 AP CHAD 360 808 5775 06/27/2006 08 53 AM DYASUMUR 06/28/2006 04 33 PM JLIERLY partial east side /j11 BL2 02 7/18/06 JLL BUILDING FOUNDATION WALL TIME 13 00 CHAD 828 5775 0 07/1/1 7/2006 07 59 AM DYASUMUR COMMENTS AND NOTES PAGE 10 DATE 7/18/06 p I j�t� b e42 /mil s Tz MC 3c1 1C_1> 'E 4 All rig •E 1- PREPARED 6/28/06 13 00 31 INSPECTION TICKET PAGE 5 CITY OF PORT ANGELES INSPECTOR JAMES L LIERLY DATE 6/28/06 ADDRESS 1809 MELODY LN SUBDIV TENANT NBR HECKMAN CONDOMINIUM CONTRACTOR VISION BUILDERS INC PHONE (360) 452 1186 OWNER NEWALL ENTERPRISES PHONE PARCEL 06 30 14 6 2 0440 0000 APPL NUMBER 06 00000099 RES NEW MULTI 5+ FAMILY PERMIT BPC 00 BUILDING PERMIT COMMERCIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BL1 01 6/09/06 JLL BUILDING FOUNDATION FOOTING TIME 13 00 6/09/06 DA CHAD 360 808 5775 06/08/2006 02 48 PM DYASUMUR 06/09/2006 04 08 PM PBARTHOL Id property lines so set back can be verified BL1 02 6/12/06 JLL BUILDING FOUNDATION FOOTING TIME 13 00 6/13/06 AP CHAD 808 5775 AM INSPECTION 06/09/2006 01 32 PM DYASUMUR 06/13/2006 08 37 AM JLIERLY 20 ground BL2 01 6/28/06 JLL BUILDING FOUNDATION WALL TIME 13 00 CHAD 360 808 5775 06/27/2006 08 53 AM DYASUMUR �(a-(1 -4 COMMENTS AND NOTES Oac E, 1,p PREPARED 6/12/06 12 12 44 INSPECTION TICKET PAGE 8 CITY OF PORT ANGELES INSPECTOR JAMES L LIERLY DATE 6/12/06 ADDRESS 1809 MELODY LN SUBDIV TENANT NBR HECKMAN CONDOMINIUM CONTRACTOR VISION BUILDERS INC PHONE (360) 452 1186 OWNER NEWALL ENTERPRISES PHONE PARCEL 06 30 14 6 2 0440 0000 APPL NUMBER 06 00000099 RES NEW MULTI 5+ FAMILY PERMIT BPC 00 BUILDING PERMIT COMMERCIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BLI 01 6/09/06 JLL 6/09/06 DA BL1 02 6/1/06 BUILDING FOUNDATION FOOTING TIME 13 00 CHAD 360 808 5775 06/08/2006 02 48 PM DYASUMUR 06/09/2006 04 08 PM PBARTHOL Id property lines so set back can be verified BUILDING FOUNDATION FOOTING TIME 13 00 CHAD 808 5775 AM INSPECTION 06/09/2006 01 32 PM DYASUMUR COMMENTS AND NOTES s •.5 '11-50 PREPARED 6/09/06 11 32 11 CITY OF PORT ANGELES INSPECTION TICKET INSPECTOR JAMES L LIERLY ADDRESS 1809 MELODY LN SUBDIV TENANT NBR HECKMAN CONDOMINIUM CONTRACTOR VISION BUILDERS INC PHONE (360) 452 1186 OWNER NEWALL ENTERPRISES PHONE PARCEL 06 30 14 6 2 0440 0000 APPL NUMBER 06 00000099 RES NEW MULTI 5+ FAMILY PERMIT BPC 00 BUILDING PERMIT COMMERCIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BL1 01 6/09/06 JLL BUILDING FOUNDATION FOOTING TIME 13 00 i CHAD 360 808 5775 06/08/2006 02 48 PM DYASUMUR COMMENTS AND NOTES S re (ow-- LR. PAGE 9 DATE 6/09/06 Job Located at Date _Cr BUILDING DIVISION CITY OF PORT ANGELES ,,..w _s.:. r� .,.+:t Correction Notice 1 so9 L EI Inspection of your work revealed that the following is not in accordance with the codes governing the work in this jurisdiction These corrections must be made and are not to be covered until reinspection is made When corrections have been made, please call c h for inspection Inspector for BuiTalFrgTiFirsion DO NOT REMOVE THIS TAG OP PORT, 4 fr Application Number Application pin number Property Address ASSESSOR PARCEL NUMBER Application type description Subdivision Name Property Use Property Zoning Application valuation Owner NEWALL ENTERPRISES 903 STRAIT VIEW DR PORT ANGELES Permit Additional desc Permit pin number Permit Fee Issue Date Expiration Date Permit Fee Total Plan Check Total Grand Total Signature of Contractor or T \Policies \1102.15R [1/05] Qty Unit Charge WA 983628476 PUBLIC WORKS RES WATER SERV FIRE HYDRANT METER 79244 42 50 Plan Check Fee 00 Valuation 0 12/02/06 Per CITY OF PORT ANGELES PUBLIC WORKS UTILITIES DIVISION 321 EAST 5TH STREET PORT ANGELES, WA 98362 06 00000579 868758 1809 MELODY LN 06 30 14 6 2 0440 0000 PUBLIC WORKS UTILITES RESIDENTIAL HIGH DENSITY 0 BASE FEE Contractor VISION BUILDERS INC 3705 CRITCHFIELD RD PORT ANGELES (360) 452 1186 Fee summary Charged Paid Credited Due 42 50 42 50 00 00 00 00 42 50 42 50 00 Date 6/05/06 WA 98363 Extension 42 50 00 00 00 Separate Permits are required for electrical work, SEPA, Shoreline ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days if construction or work is suspended or abandoned for a period of 180 days after the work as commenced or if required inspections have not been requested within 180 days from the last inspection. here• certify that I have read and examined this application and know the same to be true and correct. All provisions of con strucfi I presunu) t Igii$ y o ol or cancel the provisions of any state or local law regulating construction or the performance of laws and or nan governing his pe of work will be complied with whether specified herein or not. The granting of a permit does not s o 4 uthorized Agent Date Signature of Owner (if owner is builder) Date CALL 417 -4807 FOR UTILITY INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED COMMENTS PW UTILITIES (Engineering Division) WATERLINE METER SEWER CONNECTION SANITARY STORM SITE DRAINAGE SITE EROSION CONTROL PARKING SIDEWALK CURB GUTTER DRIVEWAY APPROACH BACK -FLOW DEVICE T \Policies \1102.15R [1/05] RESIDENTIAL PERMIT INSPECTION RECORD YES 1 NO FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE DATE YES NO COMMERCIAL DATE ACCEPTED YES I NO CONSTRUCTION R.W PW/ CONSTRUCTION R.W ENGINEERING 417 -4807 PW ENGINEERING FIRE 417 -4653 I I I I FIRE DEPT PLANNING DEPT 417 -4750 I I I I PLANNING DEPT BUILDING 417 -4815 I I BUILDING Application Number Application pin number Property Address ASSESSOR PARCEL NUMBER Tenant nbr name Application type description Subdivision Name Property Use Property Zoning Application valuation Owner NEWALL ENTERPRISES 903 STRAIT VIEW DR PORT ANGELES WA 983628476 CITY OF PORT ANGELES PUBLIC WORKS UTILITIES DIVISION 321 EAST 5TH STREET PORT ANGELES, WA 98362 06 00000099 034541 1809 MELODY LN 06 30 14 6 2 0440 0000 HECKMAN CONDOMINIUM RES NEW MULTI 5+ FAMILY RESIDENTIAL HIGH DENSITY 913115 Contractor Structure Information 000 000 6 UNIT CONDOMINIUM Other struct info TOTAL o LOT COVERAGE 28 00 Permit Additional desc Permit pin number Permit Fee Issue Date Expiration Date Permit Additional desc Permit pin number Permit Fee Issue Date Expiration Date Permit Additional desc Permit pin number Permit Fee Issue Date Expiration Date T• \Policies\ 1102.15R [1/05) HARD SURFACE AREA 1 NUMBER OF STORIES 3 00 LOT SIZE 13300 00 TOTAL LOT COVERAGE 3727 00 NUMBER OF UNITS 6 00 PUBLIC WORKS RES WATER SERV 71381 5990 00 Plan Check Fee 3/21/06 Valuation 9/17/06 Qty Unit Charge Per 6 00 715 0000 EA PW W/M 1 SERV 5/8 METER 1 00 750 0000 EA PW W/M 1 SERV 3/4 METER 1 00 950 0000 ECH HOT TAP 6 ON 6 RIGHT OF WAY 71399 50 00 Plan Check Fee 3/21/06 Valuation 9/17/06 Qty Unit Charge Per 1 00 50 0000 ECH RIGHT OF WAY PERMIT SANITARY SEWER HOOK UP Date 3/21/06 VISION BUILDERS INC 3705 CRITCHFIELD RD PORT ANGELES WA 98363 (360) 452 1186 00 913115 Extension 4290 00 750 00 950 00 00 913115 Extension 50 00 71373 150 00 Plan Check Fee 00 3/21/06 Valuation 913115 9/17/06 Qty Unit Charge Per Extension 1 00 110 0000 EA SAN SEWER HOOKUP 110 00 5 00 8 0000 EA SAN SEW HOOKUP ADD /UT 40 00 Special Notes and Comments This project will require seperate permit and fire Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days if construction or work is suspended or abandoned for a period of 180 days after the work as commenced or if required inspections have not been requested within 180 days from the last inspection I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give a hority to violate or cancel the provisions of any state or local law regulating construction or the performance of dij C1 construction. Signatur ontractor or Authorized Agent Date Signature of Owner (if owner is builder) Date PW UTILITIES (Engineering Division) WATERLINE METER SEWER CONNECTION SANITARY STORM SITE DRAINAGE SITE EROSION CONTROL PARKING SIDEWALK CURB GUTTER DRIVEWAY APPROACH BACK -FLOW DEVICE RESIDENTIAL CONSTRUCTION R.W PW/ ENGINEERING 417 -4807 FIRE 417 -4653 I PLANNING DEPT 417 -4750 I BUILDING 417 -4815 T•\Policies \1102.15R 1/05] PERMIT INSPECTION RECORD CALL 417 -4807 FOR UTILITY INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED COMMENTS YES NO FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE DATE YES NO COMMERCIAL DATE ACCEPTED YES I NO CONSTRUCTION R.W PW ENGINEERING I FIRE DEPT I PLANNING DEPT BUILDING I I I I I I I I I I Application Number Application pin number Special Notes and Comments sprinkler plans for review This project will require a seperate permit and fire alarm plans for review A minimum 2A 10BC fire exinguisher is required Extinguishers must be mounted with the top no more than 5 off the floor Suggested extinguisher placement is adjacent to an exit 02/03/2006 10 40 AM KDUBUC A KNOX locking keybox will be required Contact the Fire Department at 417 4653 for order and location information 02/03/2006 10 40 AM KDUBUC Doors to rooms containing fire sprinkler riser and fire alarm control panel must be labeled 02/09/2006 12 28 PM SROBERDS The proposal is for a 6 unit condominium in the RHD for total lot coverage of 280 No land use issues are noted Electrical load calculations and elctrical permits are required Transformer installation at customer s expense A cost estimate will be prepared after load requirements are provided 02/01/2006 01 21 PM GMCLAIN Sanitary sewer connection inspection is required by Public Works prior to back fill of ditch 24 hour advance notice is required Each unit will have its own water meter and seperate irragation meter with back flow pervention 6 pvc water main is along Melody Lane 6 fire line will require a seperate tap on water main Construct driveway and Sidewalks to City Standards No concrete with exposed aggregate allowed in the City road right of way An inspection by Public Works Engineering is required prior to prouring concrete Other Fees Fee summary T• \Policies \1102.15R 1/05] CITY OF PORT ANGELES PUBLIC WORKS UTILITIES DIVISION 321 EAST 5TH STREET PORT ANGELES, WA 98362 06 00000099 034541 Page 2 Date 3/21/06 SEWER SYSTEM DELV CHARGE 5220 00 STATE SURCHARGE 4 50 PW WATER SYSTEM USE FEE 7200 00 Charged Paid Credited Due Permit Fee Total 6190 00 6190 00 00 00 Plan Check Total 00 00 00 00 Other Fee Total 12424 50 12424 50 00 00 Grand Total 18614 50 18614 50 00 00 Separate Permits are required for electrical work, SEPA, Shoreline ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days if construction or work is suspended or abandoned for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Signature of Contractor or Authorized Agent Date Signature of Owner (if owner is builder) Date PW UTILITIES (Engineering Division) WATERLINE METER SEWER CONNECTION SANITARY STORM SITE DRAINAGE SITE EROSION CONTROL PARKING SIDEWALK CURB GUTTER DRIVEWAY APPROACH BACK -FLOW DEVICE RESIDENTIAL CONSTRUCTION R.W PW/ ENGINEERING 417 -4807 FIRE 417 -4653 I PLANNING DEPT 417 -4750 I BUILDING 417 -4815 I T•\Policies \1102.15R 1/051 PERMIT INSPECTION RECORD CALL 417 -4807 FOR UTILITY INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED COMMENTS YES I NO FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE DATE YES NO COMMERCIAL DATE ACCEPTED YES NO CONSTRUCTION R.W PW ENGINEERING I FIRE DEPT I PLANNING DEPT BUILDING w y �Oh�u Application Number Application pin number Property Address ASSESSOR PARCEL NUMBER Tenant nbr name Application type description Subdivision Name Property Use Property Zoning Application valuation Owner NEWALL ENTERPRISES 903 STRAIT VIEW DR PORT ANGELES Structure Information Other struct info Signatu Permit Additional desc Permit pin number Permit Fee Issue Date Expiration Date Permit Additional desc Permit pin number Permit Fee Issue Date Expiration Date Permit Additional desc Permit pin number 73049 Permit Fee 434 35 Issue Date 3/21/06 Expiration Date 9/17/06 Contractor or Authorized Agent CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING DIVISION 321 EAST 5TH STREET PORT ANGELES, WA 98362 06 00000099 034541 1809 MELODY LN 06 30 14 6 2 0440 0000 HECKMAN CONDOMINIUM RES NEW MULTI 5+ FAMILY Contractor WA 983628476 RESIDENTIAL HIGH DENSITY 913115 VISION BUILDERS INC 3705 CRITCHFIELD RD PORT ANGELES WA 98363 (360) 452 1186 000 000 6 UNIT CONDOMINIUM TOTAL LOT COVERAGE 28 00 HARD SURFACE AREA 1 NUMBER OF STORIES 3 00 LOT SIZE 13300 00 TOTAL LOT COVERAGE 3727 00 NUMBER OF UNITS 6 00 BUILDING PERMIT COMMERCIAL 73072 5226 75 Plan Check Fee 3/21/06 Valuation 9/17/06 Qty Unit Charge Per BASE FEE 414 00 4 7500 THOU BL -500 001 1M (4 75 PER K) ELECTRICAL NEW COMMERICAL 73056 93 40 3/21/06 9/17/06 Qty Unit Charge Per 1 00 36 4000 ECH EL -LVT FIRST THERMOSTAT 5 00 11 4000 ECH EL LVT ADD THERMOSTAT MECHANICAL PERMIT Qty Unit Charge Per BASE FEE 6 00 14 7000 ECH ME INSTALL 100- FAU 24 00 7 2500 ECH ME VENT FAN 6 00 10 6500 ECH ME VENT SYSTEM OTHER T:\Policies \1102_15 building permit inspection record05.wpd [1/4/2005] Date Plan Check Fee Valuation Plan Check Fee Valuation Date 3/21/06 3397 39 913115 Extension 3260 25 1966 50 00 0 Extension 36 40 57 00 00 0 Extension 50 00 88 20 174 00 63 90 PdG ovIeNTs �1 Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to e a thority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction Signature of Owner (if owner is builder) Date CALL 417 -4815 FOR BUILDING INSPECTIONS. CALL 417 -4735 FOR ELECTRICAL INSPECTIONS. CALL 417 -4807 FOR PUBLIC WORKS UTILITIES PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE. INSPECTION TYPE DATE ACCEPTED COMMENTS FOUNDATION: FOOTINGS WALLS FOUNDATION DRAINAGE DOWN SPOUTS PIERS POST HOLES (POLE BLDGS.) PLUMBING UNDERFLOOR /SLAB ROUGH -IN WATER LINE (METER TO BLDG) GAS LINE BACK FLOW WATER AIR SEAL WALLS CEILING FRAMING JOISTS GIRDERS SHEAR WALL/HOLD DOWNS WALLS ROOF CEILING DRYWALL (INTERIOR BRACED PANEL ONLY) T -BAR INSULATION SLAB WALL FLOOR CEILING MECHANICAL HEAT PUMP FURNACE DUCTS GAS LINE WOOD STOVE PELLET CHIMNEY COMMERCIAL HOOD DUCTS MANUFACTURED HOMES FOOTING SLAB BLOCKING HOLD DOWNS SKIRTING PLANNING DEPT SEPARATE PERMIT #'s PARKING/LIGHTING LANDSCAPING RESIDENTIAL ELECTRICAL LIGHT DEPT I I I I I I I I I I I I I I I I I I I I I I CONSTRUCTION R.W PW/ ENGINEERING 417 -4807 FIRE 417 -4653 I PLANNING DEPT 417 -4750 I BUILDING 417 -4815 T\Policies \1102_15 building permit inspection record05.wpd [1/4/2005] BUILDING PERMIT INSPECTION RECORD YES I NO I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I FINAL FINAL SEPA. ESA. SHORELINE: 417 -4735 ELECTRICAL LIGHT DEPT CONSTRUCTION R.W PW ENGINEERING I FIRE DEPT. I PLANNING DEPT BUILDING DATE ACCEPTED BY. DATE ACCEPTED BY. FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE DATE YES NO COMMERCIAL DATE ACCEPTED YES I NO I I I I I I I I I o -pORT k a Page 2 Application Number 06 00000099 Date 3/21/06 Application pin number 034541 Qty Unit Charge Per Extension 5 00 10 6500 ECH ME -GAS PIPE 1 TO 5 53 25 1 00 5 0000 ECH ME -GAS PIPE 5+ 5 00 Permit PLUMBING PERMIT Additional desc Permit pin number 73064 Permit Fee 644 00 Plan Check Fee 00 Issue Date 3/21/06 Valuation 0 Expiration Date 9/17/06 Qty Unit Charge Per Extension BASE FEE 50 00 60 00 7 0000 ECH PL EA FIXTURE ON ONE TRAP 420 00 6 00 7 0000 ECH PL- EA INSTALL WATER PIPE 42 00 6 00 15 0000 ECH PL- EA BLDG SEWER 90 00 6 00 7 0000 ECH PL- EA WATER HEATER 42 00 Special Notes and Comments This project will require seperate permit and fire sprinkler plans for review This project will require a seperate permit and fire alarm plans for review A minimum 2A 10BC fire exinguisher is required Extinguishers must be mounted with the top no more than 5 off the floor Suggested extinguisher placement is adjacent to an exit 02/03/2006 10 40 AM KDUBUC A KNOX locking keybox will be required Contact the Fire Department at 417 4653 for order and location information 02/03/2006 10 40 AM KDUBUC Doors to rooms containing fire sprinkler riser and fire alarm control panel must be labeled 02/09/2006 12 28 PM SROBERDS The proposal is for a 6 unit condominium in the RHD for total lot coverage of 28% No land use issues are noted Electrical load calculations and elctrical permits are required Transformer installation at customer s expense A cost estimate will be prepared after load requirements are provided 02/01/2006 01 21 PM GMCLAIN Sanitary sewer connection inspection is required by Public Works prior to back fill of ditch 24 hour advance notice is required Each unit will have its own water meter and seperate irragation meter with back flow pervention 6 pvc water main is along Melody Lane 6 fire line will require a seperate tap on water main Construct driveway and Sidewalks to City Standards No concrete with exposed aggregate allowed in the City road right of way An inspection by Public Works Engineering is required prior to prouring concrete Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work orconstruction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Signature of Contractor or Authorized Agent Date Signature of Owner (if owner is builder) Date T•\Policies \1102_15 building permit inspection record05.wpd [1/4/2005] CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING DIVISION 321 EAST 5TH STREET PORT ANGELES, WA 98362 CALL 417 -4815 FOR BUILDING INSPECTIONS. CALL 417 -4735 FOR ELECTRICAL INSPECTIONS. CALL 417 -4807 FOR PUBLIC WORKS UTILITIES PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE. INSPECTION TYPE DATE ACCEPTED COMMENTS FOUNDATION: FOOTINGS WALLS FOUNDATION DRAINAGE DOWN SPOUTS PIERS POST HOLES (POLE BLDGS.) PLUMBING UNDER FLOOR SLAB ROUGH -IN WATER LINE (METER TO BLDG) GAS LINE BACK FLOW WATER AIR SEAL WALLS CEILING FRAMING JOISTS GIRDERS SHEAR WALL/HOLD DOWNS WALLS ROOF CEILING DRYWALL (INTERIOR BRACED PANEL ONLY) T -BAR INSULATION SLAB WALL FLOOR CEILING MECHANICAL HEAT PUMP FURNACE DUCTS GAS LINE WOOD STOVE PELLET CHIMNEY COMMERCIAL HOOD DUCTS MANUFACTURED HOMES FOOTING SLAB BLOCKING HOLD DOWNS SKIRTING PLANNING DEPT SEPARATE PERMIT #'s PARKING/LIGHTING LANDSCAPING RESIDENTIAL ELECTRICAL LIGHT DEPT BUILDING PERMIT INSPECTION RECORD I I I I I I I I I I I I I I I I I I I I I f I I I I I I I I I I 1 CONSTRUCTION RW PW/ ENGINEERING 417 -4807 FIRE 417 -4653 I PLANNING DEPT 417 -4750 I BUILDING 417 -4815 I r•\Policies \1102_15 building permit inspection record05.wpd [1/4/2005] YES I NO FINAL FINAL SEPA. ESA. SHORELINE. DATE ACCEPTED BY. DATE ACCEPTED BY. FINAL. INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE DATE YES NO COMMERCIAL DATE ACCEPTED YES I NO 417 -4735 ELECTRICAL LIGHT DEPT CONSTRUCTION RW PW ENGINEERING I FIRE DEPT. I PLANNING DEPT I BUILDING I I I I I I I I I r r r W Application Number Application pin number. T•\Policies \1102_15 building permit inspection record05.wpd 1/4/2005] CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING DIVISION 321 EAST 5TH STREET PORT ANGELES, WA 98362 06 00000099 034541 Fee summary Charged Paid Credited Due Page 3 Date 3/21/06 Other Fees SEWER SYSTEM DELV CHARGE 5220 00 STATE SURCHARGE 4 50 PW WATER SYSTEM USE FEE 7200 00 Permit Fee Total 6398 50 6398 50 00 00 Plan Check Total 3397 39 3397 39 00 00 Other Fee Total 12424 50 12424 50 00 00 Grand Total 22220 39 22220 39 00 00 Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Signature of Contractor or Authorized Agent Date Signature of Owner (if owner is builder) Date BUILDING PERMIT INSPECTION RECORD CALL 417 -4815 FOR BUILDING INSPECTIONS. CALL 417 -4735 FOR ELECTRICAL INSPECTIONS. CALL 417 -4807 FOR PUBLIC WORKS UTILITIES PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE. INSPECTION TYPE DATE ACCEPTED FOUNDATION FOOTINGS WALLS FOUNDATION DRAINAGE DOWN SPOUTS PIERS POST HOLES (POLE BLDGS.) PLUMBING UNDER FLOOR SLAB ROUGH -IN WATER LINE (METER TO BLDG) GAS LINE BACK FLOW WATER AIR SEAL WALLS CEILING FRAMING West 5iwrs lkoh5`I JIL 01005- Mq i GU SHEAR WALL/HOLD DOWNS L /a I v kt, JOISTS GIRDERS WALLS/ROOF/CEILING DRYWALL (INTERIOR BRACED PANEL ONLY) 13 ht fl 5/ SI b i T I L T -BAR T INSULATION SLAB WALL FLOOR CEILING MECHANICAL HEAT PUMP FURNACE DUCTS GAS LINE WOOD STOVE PELLET CHIMNEY COMMERCIAL HOOD DUCTS MANUFACTURED HOMES FOOTING SLAB BLOCKING HOLD DOWNS SKIRTING PLANNING DEPT SEPARATE PERMIT #'s PARKING/LIGHTING LANDSCAPING RESIDENTIAL ELECTRICAL LIGHT DEPT 417 -4735 I I M 0C/2A 10+ I I 1 I YES NO SEPA. ESA. SHORELINE. FINAL. INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE DATE YES NO COMMERCIAL CONSTRUCTION RW PW/ ENGINEERING 417 -4807 FIRE 417 -4653 I PLANNING DEPT 417 -4750 I p BUILDING -77-t1 3 417-4815 I IQ" I�'t 1 I ILL T•\Policies \1102_15 building permit inspection record05.wpd [1/4/2005] ELECTRICAL LIGHT DEPT CONSTRUCTION RW PW ENGINEERING I FIRE DEPT I PLANNING DEPT I BUILDING COMMENTS mono S/ -b 8/8 /o6 4PJ 1 /66 06 4e .i Rovg,tykl Pivihbihq 5tgi Ttl- vai t 0Z "ILL- a, U t1145 FINAL 115 I O 1 DATE ACCEPTED BY. 5;110A 'q LL -4 4 tl tni" c� rseal jb (oar '4Izo)oi 3LL Fire Seal 4 1 2 10` 7 3 4L Qirseat 5/2 /o7 Shear wall 4125 1 (37 ;u- 9, 6 J L1— 5; 9 //4 /-1-. 5 shy �ramin 5 torF1,00 r 1 4120/o7 �lL. ifl t�c( Vent 5 IN aft 41 2.51o1 Tt.L 11' y �l� heri,�wQ r DLL elevad'or ;ova 6,►tie n 5 116(tr7'SU- insvlation w1t3 JLt Stcohd Floor i nsula ion 5/3(o'7 W. I theA.nx. i cal I Rough -t r+ -r,o f floor 4 a12o 6,00 to 1Z- ALL ��.c�l.S C F redr,)n9 SI'ioy v S CQ ^°I Floor 1 x /07 TCL FINAL 13' l5/ DATE ACCEPTED BY. q z1 o 1 TLI. ai 4 Urn ]t "retY1 o+�t� Cof SII‘5107- 11i51o7 e +o() /f (00'r 2y 0+5 T U- DATE ACCEPTED YES I NO 1 MLCC•802.2 PRINTED IN U.S.A. LINDBERG SMITH A R C H I T E C T S March 14, 2006 Mr Jim Lierly Building Official, Dept. of Community Development City of Port Angeles Port Angeles, WA 98362 -0217 R P• A eek.m.an..Cnnri nmini]] m. Mer_hanir_al CITY OF PORT ANGELES BUILDING DIVISION TO r f:=06.N/ F ern y =left r LINDBE ITH CEIVED AR C H I C T S MAR 15 16 tbl e• body suite b p ort ang email conta eles, wa 98362 360.452.6116 fax 360.452.7064 c t @l www.lindarch.com DATE is RECEIVED M AR 1 5 2006 CITY OF PORT ANGELES BUILDING DIVISION 2 2 SUBJECT t/_‘&.L4c4ALL Caz ,e4647 J4; U ,424,1/4 .161-1.4e-- o 4 ,//s pLeLm A C',v,4 _4-r,,� J) /7;a, T .dt,L uJ. jj JA r S TS (A -Z. I 44-2.2) LINDBERG SMITH A R C H I T E C T S March 9 2006 Mr Jim Lier Building %:)ffie,tal, Dept. of Community Development City cf Port Angeles Port Angeles, WA 98362 -0217 Re Heckman Condominium Vletody Matte Dear Jail This letter is a follow -up to our March 7 phone conversation and review of responses .o your review comments. All responses were determined to be acceptable with the ,.xception of item #9 regarding location of an accessible parking stall for visitors and Item 414 regarding design loads. ;ti re t tf Item -9 we ha` attached a revised. site plan showing a new ha. eft na; king s-7 n the north side of thc building providing access at grade to the LlCVat) response to [tern #14 and your concetns.about the structural calcs, we have attached a 'espons:. lroln Fct Joiisori, the structural engineer He clarifies that his calculations arc fc- Ac.te D. id that the drifting snow factoris included n his calculations. Also, in reference to Item #5 regarding the storage in the parking level, we have directed he contractor that all storage room walls must be provided with 5/8" Type X GWB We antic spate that this information will be sufficient to allow the permit process to move forward. I hank you for your time in resoh-tng these Items Sincerely I INBBERC &SMITH ARCHITECTS Ii111 (trees 319 south peabody suite b port angeles wa 98362 360 452.6116 fax 360 452 7064 email contact@lindarch.com www.lindarch.com m KN Date March 8, 2006 To Bill Green Firm Lindberg &Smith Architects Fax No Structural review comments Site class D2 and D The spectral response acceleration factor for site class D2 and D are the same. Snow loads. The design snow load used for this project is 25 psf 5 psf 30 psf. The additional 5 psf used on the entire roof is for drifting snow If you have any questions please call Sincerely, Edward Jonson and Associates, P S Edward Jonson P.E President For EDWARD JONSON AND ASSOCIATES, P S Consulting Structural Engineers 5990 Northeast Battle Point Drive Bainbridge Island, WA 98110 (206) 780 -0524 Fax (206) 780 -5587 Approval /Comments Coordination Correctio Information Hard copy will will not be sent Project Heckman Condominium From Ed Jonson No of pages 1 (including cover) File Per your request 02/28/2006 TUE 15 55 FAX 3 v�Z LINDBER ,SMITH A R C H I I .E C T S February 28,2006 Mr Jim i.ierly Building Official, Dept of Community Development City of Port Angeles Port Angeles, WA 98362 -0217 Re: Heckman Condominium Melody Lane Dear Jim, This letter is in response to your drawing review letter dated February 24, 2006 We understand that this is a preliminary review and additional items may be forthcoming We will attempt to address each of your review items with a written comment and will provide revised drawings if deemed necessary 4 Site. An Erosion Control and Drainage Plan developed by Zenovic Engineers was submitted with the permit sets and should meet the requirements of the City Plan. It is not clear from your comment where the additional smoke detector is required but it certainly is not a problem to add. We can add a written statement to be attached to the permit sets stipulating that all detectors are to be wired together Plan. This comment regarding stairs and ramps is somewhat confusing. The drawings show two exterior exit stairs separated from the building by a covered deck. However, some confusion may result from the fact that we have provided partial enclosure walls to protect them from the weather We assumed that exterior stairs did not require a fire rated enclosure. Section 1022.3 of the IBC requires that exterior exit stairways be open on at least one side. Our design complies with this requirement as well as having openings at the landing level. Section 1022.6 referenced in your letter addresses separation of exterior stairs from the interior of the building by rated construction as specified in Section 1019 1 However, our exten or stairs, as designed, are physically separated from the building by a 5 ft deck and it doesn't appear that this requirement would be applicable in our condition. We would like to discuss this matter with you for further clarification. Plan. Type `B" Units_ All of the units are adaptable as Type "B" Units. Grab bars are shown as hidden lines at the Master Bath toilets and showers. This 319 south pcabody suite h port ange]es wa 98362 360 452.6116 fax 360.452.7064 email contaulglindarch_com www.lindarch.com 02/28/2006 TUE 15 56 FAX 5 tgel 0 y 0:: e )r 0 issue has been discussed with the owner and contractor and blocking will be provided at these locations for future installation of grab bars if desired. The doors in each unit are also accessible. Plan. A fire rated separation between the Parking and Storage areas was not provided because we felt that since the storage areas are not heated they were better categorized as S -2 storage which is the same category as the parking. We understand that a variety of items are typically stored in these type of units but without heat, it would not be practical to store many of the items listed in the S -1 category (furniture, clothing, etc). If in your opinion these truly are S- 1 storage units we would like to request that the units directly adjacent or facing the parking be left as S -2 sincethey would only comprise 8% of the total square footage. We would then provide a 1 -hour separation between the larger storage rooms and the remainder of the building. Footnote "c of table 302.3.2 allows the 1 -hour separation. Plan. Penetrations of the wall between the two units at each level should not occur We have planned for mechanical units to supply each side of the building separately so that penetrations would not occur However, we would be happy to add such a note to the drawings. Plan. We will add this note to the drawings. Plan. It is not clear from you note which area you are making reference to regarding the fire -rated walls and ceilings. We would appreciate the opportumty to discuss this item with you further in order to fully understand where this requirement applies. We were under the assumption (as listed on Sheet A -1 0) that we qualified as a Type VB structure and with sprinklers should not have rated assemblies other than as listed above. Plan. This requirement is difficult to meet from the street side parking area. We could accommodate one handicap parking stall in the alley with access to the elevator through the parking level. We would need to discuss this further with you to see what would be acceptable. Plan. The intent of this comment is not clear since we assumed that the elevator made all of the units accessible. There are numerous other condominium projects in Port Angeles that arc similar to this proposed project. The tenant parking is at grade in the parking level and access to the elevator which is also at grade is accessible from the tenant parking. Further clarification of the intent of this comment is desired. Plan. The cab of the elevator selected for this project and listed in the drawings on Sheet A -2.0 is 6' -8" by 4' -3" clear inside. The size of the ambulance stretcher listed in Section 3002.4 is 24 "x76' which easily fits inside of the cab. Detail. The elevator shaft is shown on Sheet A-4 1 of the project drawings to have a vent at the top of the shaft to meet this requirement. Detail. See item #12 above. Design. All of the design loads are listed on Sheet S -1 of the structural drawings. i ce, S(zr,s„w,. c, foQ rtl P CA- L fl 0003 02/28/2006 TUE 15 56 FAX J 004 We look forward to the opportunity to clarify and resolve all of these items with you so this project can move forward through the completion of the permitting process. Sincerely, Bill Green for Lindberg Smith Architects 02/28/2006 TUE 15 55 FAX 319 South Peabody Street, Suite B Port Angeles, WA 98362 Phone (3 60) 452 -6116 Fax (360) 452 -7064 DATE: 2..2 TO h L- FIRM. FAX NO 4 -7 47 LINDB]ERG SMITE ARCHITECTS, INC. For Approval/Comments Corrections lgarci copy avill will not be sent i PROJECT NO PROJECT r C FROM. NO OF PAGES 4- (including cover) n ..c>. 4 Goa Coordination Information If this material is nafccorapletely received, please notify us immediately at, (3 60) 452 -6116 Fi1c Per Your Request IeULU Project Number Project Name Address SHEET IDENTIFICATION CORRECTION REQUIRED 3 plan 4 plan 5 plan City of Port Angeles Community Developement (Building Division) 321 E 5th St Port Angeles Washington 98362 360 417 -4815/ Fax 417 -4711 Plan analysis based on the 2003 International Building Code Contractor Date February 24, 2006 Occupancy Construction Engineer Report By JIM LIERLY NOTE The code items listed in this report are not intended to be a complete listing of all possible code requirements in the 2003 IBC It is a guide to selected sections of the code 1 site 4 Erosion control is required per The City of Port Angeles Public Works Dept 2 plan A smoke detector is required in this location NOTE All detectors are be wired together Sec 907 2 10 1 2 Stairs and /or ramps do not comply with section 1022 6 of the 2003 IBC Stairs and ramps are required to be protected from openings by separation or rated enclosure Type "B" units Where there are four or more dwelling units or sleeping units intended to be occupied as a residence in a single structure, every dwelling unit and sleeping unit intended to be occupied as a residence shall be a Type "B" unit This is required to be a hour fire resistive assembly since it is a fire barrier to separate different occupancy (use) areas Sec 302 3 2 and Table 302 3 2 0.1- a_ 2 S 2 a tip-. Code review for Project Id Address 6 plan 7 plan 8 plan 9 plan 10 plan 11 plan 12 details 13 details 14 design Page 2 Penetrations of fire rated walls shall be protected Sec 712 3 Ducts and air transfer openings through fire assemblies are required to be protected Sec 716 The wall and ceiling finish material in this area must comply with Class C. requirements Sec 803 5 and Table 803 5 At least one accessible route shall connect each accessible level Sec 1104 4 At least 50 percent but not less than one entrance shall comply with accessibility requirements Sec 1105 1 At least one elevator is required to accommodate an ambulance -type stretcher Sec 3002 4 Elevator hoistways are required to vent smoke and hot gases Sec 3004 1 Show the location and size of smoke and heat vents Sec 910 Show all design loads used in the design of this building on the plans (snow, wind, seismic, live etc Sec 1603 1 Project Number 06 -99 Project Name Condomiumn Address 1809 melody In Occupancy R -2 S -1,S -2 Construction V -A City of Port Angeles Community Developement (Building Division) 321 E 5th St Port Angeles, Washington 98362 360- 417 -4815/ Fax 417 -4711 Plan analysis based on the 2003 International Building Code Contractor Architect Engineer Report By Date February 22, 2006 Vision Builders Linberg Smith Edward Johnson JIM LIERLY NOTE The code items listed in this report are not intended to be a complete listing of all possible code requirements in the 2003 IBC It is a guide to selected sections of the code Report created using Plan Analyst software by IHS Global 800 854 -7179 FRONTAGE INCREASE Perimeter of the entire building 282 feet Perimeter which fronts a public way or accessible open space 141 feet Minimum width of public way or accessible open space 20 Allowable area increased 16 67% for frontage increase Sec 506 2 FL NAME OCC MAX FLR AREA ALLOWED RATIO STATUS 3 Condos R -2 3 Condos R -2 TOTAL FOR FLOOR 2 Condos R -2 2 Condos R -2 TOTAL FOR FLOOR 1 Condos R -2 1 Condos R -2 TOTAL FOR FLOOR B1 Parking Garage S -2 B1 Storage /Stock Room S -1 TOTAL FOR FLOOR BUILDING TOTAL Sec 503 504 506 and Table 503 ok 2015 14000 0 14 ok ok 2014 14000 0 14 ok 4029 14000 0 29 ok ok 2015 14000 0 14 ok ok 2014 14000 0 14 ok 4029 14000 0 29 ok ok 2015 14000 0 14 ok ok 2014 14000 0 14 ok 4029 14000 0 29 ok ok 1963 24500 0 08 ok ok 2066 16333 0 13 ok 4029 19500 0 21 ok 12087 42000 0 29 ok Code review for Project Id Condomiumn Address 1809 melody In Page 2 Allowable area and height calculations are based on different uses being separated by fire barriers Sec 302 3 2 Basement area not included in the total when checking allowable area Sec 503 1 1 The actual height of this building is 40 0 feet The maximum height of this building is 50 0 feet Table 503 PROPERTY DESCRIPTION North Side has a property line Distance to property line 25 0 East Side has a property line Distance to property line 11 0 South Side has a public way Distance to public way 25 0 width 70 0 Exterior wall rating based on distance to center line of public way Sec 702 1 FIRE SEPARATION DISTANCE West Side has a public way Distance to public way 14 0 width 70 0 Exterior wall rating based on distance to center line of public way Sec 702 1 FIRE SEPARATION DISTANCE EXTERIOR WALL FIRE RATINGS AND OPENING PROTECTION Sec 602 Tables 601 and 602, and Sec 704 NORTH OCC BRG NON OPNG% WALL BRG UP /PR R -2 1- hr *1- hr *45 /NL S -1 1- hr *1- hr *45 /NL S -2 1- hr *1- hr *45 /NL EAST BRG NON OPNG% WALL BRG UP /PR 1- hr *1 -hr *15/45 1- hr *1 -hr *15/45 1- hr *1 -hr *15/45 SOUTH BRG NON OPNG% WALL BRG UP /PR 1- hr *0- hr *NL /NL 1- hr *0- hr *NL /NL 1- hr *0- hr *NL /NL WEST BRG NON OPNG% WALL BRG UP /PR 1- hr *0- hr *NL /NL 1- hr *0- hr *NL /NL 1- hr *0- hr *NL /NL The exterior walls may be of COMBUSTIBLE material Sec 602 5 Exterior walls are required to be fire -rated for exposure to fire 1 From Both sides when fire separation is 5 feet or less 2 On the interior side only when separation is greater than 5 feet Sec 704 5 Code review for Project Id Condomiumn Address 1809 melody In Page 3 up /pr Maximum percent of openings in the exterior wall Table 704 8 up The maximum percent if all openings are unprotected pr The maximum percent if all openings are protected If some are protected and some are not, then use formula in Sec 704 8 Openings in lhr walls are required to be protected with 3/4 hour assemblies Sec 704 12 and Sec 715 4 Openings in walls required to be greater than lhr are required protected with 1 1/2 hour assemblies Sec 715 4 NL No fire protection requirements for openings NP Openings are not permitted in this wall These walls may be required to have a parapet wall 30 inches above the roofing The parapet wall is required to have the same fire rating as the wall and shall have noncombustible faces for the uppermost 18 inches Sec 704 11 Exception 1 A parapet wall is not required when the wall is not required to be fire resistive Exception 4 A parapet wall is not required on 1 -hour fire resistive exterior walls provided 4 1 Where roof /ceiling framing are parallel to the wall framing and support shall be not less than 1 -hour fire resistive for a minimum width of 4 feet from the inside of the exterior wall 4 2 Where roof /ceiling framing are not parallel to the wall, the entire span of framing and support shall be not less than 1 -hour fire resistive 4 3 Openings in the roof shall not be located within 5 feet of the exterior wall 4 4 The entire building shall be provided with not less than a Class B roof covering Code review for Project Id Condomiumn Address 1809 melody In Page 4 FIRE RESISTANCE RATINGS FOR BUILDING ELEMENTS Table 601 ELEMENT MATERIAL RATING NOTES Structural Frame Any 1 hour Interior Bearing wall Any 1 hour Interior nonbrg wall Any 0 hr Shaft Enclosure Any 2 hour Note 1 Floor /Ceiling Assembly Any 1 hour Note 9 Roof /Ceiling Assembly Any 1 hour Note 8, 4 Stairs Any None NOTES 1 Fire resistance rating for shafts based on Section 707 4 NOTE See Section 707 2 for shaft enclosure exceptions 4 Heavy timber shall be permitted where a 1 hour or less fire rating is required Table 601, c 2 8 Except in Fl, H, M and S1 uses fire protection is not required for structural members including protection of roof framing and decking where every part of the roof construction is 20 feet or more above any floor immediately below Fire retardant treated wood members are permitted to be used for unprotected members Table 601, c 1 9 Parking surfaces shall be of concrete or similar noncombustible and nonabsorbent materials Asphalt parking surfaces are permitted at ground level Sec 406 2 6 SHAFT REQUIREMENTS Openings other than those necessary for the purpose of the shaft shall not be permitted Sec 707 7 1 Penetrations other than those necessary for the purpose of the shaft shall not be permitted Sec 707 8 1 Shafts that do not extend to the bottom of the building shall 1 Be enclosed at the lowest level with the same fire resistance rating as the lowest floor but not less than the rating of the shaft enclosure; or 2 Terminate in a room having a use related to the purpose of the shaft The room and openings shall have a fire resistance rating at least equal to the shaft enclosure; or 3 Be protected by approved fire dampers installed at the lowest floor level within the shaft enclosure Sec 707 11 Code review for Project Id Condomiumn Address 1809 melody In Page 5 REFUSE AND LAUNDRY CHUTES Openings into chutes shall not be located in exit access corridors Sec 707 13 1 Access openings shall be located in rooms or compartments completely enclosed by construction that has a fire resistance rating of not less than 1 hour and openings into access rooms shall be protected by openings having a fire protection rating of not less than 3/4 hour Sec 707 13 3 Chutes shall discharge into a enclosed room completely separated from the remainder of the building by construction that has a fire resistance rating of not less than 1 hour and openings into access rooms shall be protected by openings having a fire protection rating of not less than 3/4 hour Sec 707 13 4 A fire sprinkler system shall be installed Sec 707 13 6 System shall be installed at the top and in the terminal room Chutes extending through three or more floors shall also have heads at alternate floors Sec 903 2 10 2 PENETRATIONS OF FIRE RESISTIVE ASSEMBLIES Sec 712 WALLS ASSEMBLIES Sec 712 3 Through penetrations of walls 1 Penetrations shall be installed as tested in the fire resistance rated assembly Sec 712 3 1 1 2 Penetrations shall be protected by an approved penetration firestop system with a minimum positive pressure differential of 0 01 inch of water and shall have an F rating of not less than the required rating of the wall penetrated Sec 712 3 1 2 Exception Where penetrating items are steel, ferrous or copper pipes or steel conduits, the annular space between the and the penetrating item and the fire resistance rated wall shall be permitted to be protected as follows 1 In concrete or masonry walls where the penetrating item is a maximum of 6 inches nominal diameter and the openings is a maximum 144 square inches concrete, grout or mortar shall be permitted 2 The material used to fill the annular space shall prevent the passage of flame and hot gasses sufficient to ignite cotton Code review for Project Id Condomiumn Address 1809 melody In Page 6 Membrane penetrations of walls The requirements are the same as for through penetrations Sec 712 3 2 Exceptions 1 Steel electrical outlet boxes that do not exceed 16 square inches provided that the area of such openings does not exceed 100 square inches for any 100 square feet of wall area Boxes on opposite sides of the assembly shall be separated by a horizontal distance of not less than 24 inches 2 Sprinklers with metal escutcheon plates FLOOR /CEILING AND ROOF /CEILING ASSEMBLIES Sec 712 4 Through penetrations of fire resistive horizontal assemblies 1 Through penetrations shall be installed as tested in an approved fire resistance rated assembly Sec 712 4 1 1 2 Penetrations shall be protected by an approved penetration firestop system with a minimum positive pressure differential of 0 01 inch of water and shall have an F rating and a T rating of not less than 1 hour but not less than the required rating of the floor penetrated Sec 712 4 1 2 Exceptions 1 When penetrating items are steel, ferrous or copper conduits, pipes tubes and vents through a single concrete floor, the annular space shall be permitted to be grout or mortar The minimum thickness is the thickness required to maintain the fire rating The maximum size of the penetrating items is equivalent to a 6 -inch diameter and the opening is a maximum of 144 square inches 2 Electrical outlet boxes that have been tested for use in fire assemblies Membrane penetrations of fire resistive horizontal assemblies The requirements are the same as for through penetrations Sec 712 4 2 Exceptions 1 When penetrating items are steel, ferrous or copper conduits electrical outlet boxes pipes, tubes and vents through concrete or masonry and the annular space is protected by an approved penetration firestop assembly or protected to prevent the free passage of flame and products of combustion Such penetrations shall not exceed an aggregate area of 144 square inches in any 100 square feet of ceiling area in assemblies without penetrations 2 Electrical outlet boxes that, have been tested for use in fire assemblies 3 Sprinklers with metal escutcheon plates Code review for Project Id Condomiumn Address 1809 melody In Page 7 DUCTS AND AIR TRANSFER OPENINGS Sec 716 Dampers shall be accessible for inspection and servicing 716 4 Where required Sec 716 5 1 Fire walls Sec 716 5 1 2 Fire barriers Sec 716 5 2 See exceptions 3 Shaft enclosures Sec 716 5 3 See exceptions 4 Fire partitions Sec 715 5 4 See exceptions 5 Smoke barriers Sec 715 5 5 (smoke damper) See exceptions DRAFTSTOPPING If there is combustible construction in the floor /ceiling assembly draftstopping shall be installed in line with unit separations Sec 717 3 2 If there is combustible construction in the roof /ceiling assembly, draftstopping shall be installed in line with unit separation walls that do not extend to the roof sheathing Sec 717 4 2 Attic space may be subdivided into areas not exceeding 3,000 sq ft or above every two dwelling units whichever is smaller Exception 3 Opening in the partitions shall be protected by self- closing doors with automatic latches constructed as required for the partitions Sec 717 4 1 1 OCCUPAAry PEPaRATIONS Sec 302 3 2 and Table 302 3 2 R -2 to S -1 3 -hour fire barrier Openings in this fire barrier are required to be protected with 3 hour fire assemblies Table 715 3 R -2 to S -2 2 -hour fire barrier Openings in this fire barrier are required to be protected with 1 1/2 hour fire assemblies Table 715 3 NOTE Areas used only for private or pleasure vehicles may be reduced by 1 hour Table 302 3 2 c S -1 to S -2 3 -hour fire barrier Openings in this fire barrier are required to be protected with 3 hour fire assemblies Table 715 3 NOTE Areas used only for private or pleasure vehicles may be reduced by 1 hour Table 302.3 2 c Except when required by Table 302 1 1 accessory areas occupying 10% or less of the area of any floor and not more than the area or height listed in Table 503 are not required to be separated Sec 302 2 Code review for Project Id Condomiumn Address 1809 melody In Page 8 SEPARATION OF INCIDENTAL USE AREAS Table 302 1 1 Furnace rooms where any piece of equipment is over 400 000 BTU per hour input 1 hour Rooms with any boiler over 15 psi and 10 horsepower 1 hour Refrigerant machinery rooms 1 hour Parking garages 2 hours Incinerator rooms 2 hours NOTE An automatic sprinkler system is required Laundry rooms over 100 square feet 1 hour Storage rooms over 100 square feet 1 hour Waste and linen collection rooms over 100 square feet 1 hour Dwelling units are required to be separated by a fire partition Sec 708 1 The minimum fire resistance rating shall be 1 hour Sec 708 3 Openings in partitions are required to have a 3/4 hour rating Table 715 3 Note This list covers only the most common uses See Table 302 1 1 for a complete list EXIT REQUIREMENTS FL NAME NUMB MIN MIN PANIC CORRIDOR DOOR NOTES OCC EXITS WIDTH HDWR RATING SWING 3 Condos 10 1 2 0 No None N/R 3 Condos 10 1 2 0 No N/A N/R TOTAL FOR FLOOR 20 2 6 0 No 1 hour N/R 2 Condos 10 1 2 0 No None N/R 2 Condos 10 1 2 0 No N/A N/R TOTAL FOR FLOOR 20 2 6 0 No 1 hour N/R 1 Condos 10 1 2 0 No None N/R 1 Condos 10 1 2 0 No None N/R TOTAL FOR FLOOR 20 2 4 0 No 1 hour N/R 11 Bl Parking Garage 10 1 2 0 No None N/R B1 Storage /Stock Room 7 1 1 4 No None N/R TOTAL FOR FLOOR 17 2 5 1 No None N/R FOOTNOTES 11 Note If 2nd floor and basement exit through the first floor exiting on the first floor is to be based on egress convergence Base exiting requirements on the 1st floor using the sum of the occupants on the 2nd floor and in the basement Sec 1004 5 Code review for Project Id Condomiumn Address 1809 melody In NOTES FOR EXIT TABLE Door swing is based on Section 1008 1 2 Occupant load is based on Section 1004 and Table 1004 1 2 Exit width is in inches and based on Section 1005 1 Table 1005 1 Width shown for all areas is based on other egress components Width shown for 1st floor is based on other egress components Width shown for other floors basements is based on stairways For the minimum width of doors see Section 1008 1 1 For the minimum width of corridors see Section 1016 2 For the minimum width of stairways see Section 1009 1 Exits shall be continuous from the point of entry into the exit to the exit discharge Sec 1003 6 If 'CORRIDOR RATING' N/A There is no corridor in this area Page 9 If 'CORRIDOR RATING' None Walls and ceilings of corridors are not required to be fire- resistive unless they are required to be fire resistive based construction type Table 1016 1 There is no restriction as to the amount and type of openings unless protection of openings is required by some other code provision If 'CORRIDOR RATING 1 hour or 1/2 hr Walls shall be fire resistive Table 1016 1 Walls shall extend to the underside of the floor /roof slab or deck or to the fire resistance rated floor /ceiling or roof /ceiling assembly above Sec 708 4 Exception 2 Where the room -side membrane is carried through to the underside of a fire resistance rated floor or roof, the ceiling of the corridor shall be permitted to be protected by the use of ceiling materials as required for a 1 -hour rated system or the ceiling shall be constructed as required for the corridor walls Door openings are required to be protected with 20 minute (1/3 hour) fire assemblies Sec 715 3 3 Table 715 3 Doors shall be self closing or automatic closing Sec 715 3 7 Doors shall have an active latch bolt that will secure the door when closed Sec 715 3 7 1 Code review for Project Id Condomiumn Address 1809 melody In Page 10 Window openings are required to be protected with labeled 45 minute (3/4 -fire- hour) fire assemblies Sec 715 4 Table 715 4 Exception Glazing in 0 5 -hour walls is permitted to have an 0 33 -hour rating The total area of windows shall not exceed 25 percent of the area of a common wall with any room Sec 715 4 7 2 Corridors shall not serve as supply return, exhaust relief or ventilation air ducts or plenums Sec 1016 4 See Exceptions Fire resistant corridors shall not be interrupted by intervening rooms Sec 1016 5 Exception Foyers lobbies or reception rooms constructed as required for corridors When more than one exit is required, exit access shall be arranged such that there are no dead ends in corridors more than 20 feet Sec 1016 3 EXIT SEPARATION In areas where 2 exits are required, the minimum separation is 1/2 of the maximum diagonal of the area or floor measured in a straight line between exits or exit access doorways Sec 1014 2 1 Multiple means of egress shall be sized such that the loss of any one means of egress shall not reduce the available capacity by more than 50 percent Sec 1005 1 EXIT SIGNS Exits and exit access doors shall be marked by an approved exit sign Signs shall be placed where the exit or the path of egress travel is not immediately visible No point to be more than 100 feet from an exit sign Sec 1011 1 Exception 1 Exit signs are not required in rooms or areas which require only one exit Exception 2 Main exterior exit doors which obviously and clearly are identifiable as exits need not be signed when approved Exit signs shall be internally or externally illuminated Sec 1011 2 Exit sign shall be illuminated at all times including during loss of primary power Sec 1011 4 Sec 1011 5 3 Code review for Project Id Condomiumn Address 1809 melody In Page 11 BOLT LOCKS Manually operated flush bolts and surface bolts are not permitted Sec 1008 1 8 4 Exception 1 Bolt locks are permitted on doors not required for egress in dwelling units LOCKS AND LATCHES Egress doors shall be readily openable from the egress side without the use of a key or any special knowledge or effort Sec 1008 1 8 Locks and latches shall be permitted to prevent operation where any of the following exists Exception 3 Where egress doors are used in pairs, automatic flush bolts shall be permitted to be used, provided the door leaf having the automatic flush bolts has no doorknob or surface mounted hardware Exception 4 Doors from individual dwelling or sleeping units of Group R occupancies having an occupant load of 10 or less are permitted to be equipped with a night latch dead bolt or security chain provided such devices are openable from the inside without the use of a key or tool ADDITIONAL DOORS Where additional doors are provided for egress purposes, they shall conform to the requirements in Section 1008 1 LANDINGS AT DOORS 1 There shall be a floor or landing on each side of a door Sec 1008 1 4 2 Such floor or landing shall be at the same elevation on each side of the door Sec 1008 1 4 3 The floor or landing shall not be more than 1/2 inch lower than the threshold Sec 1008 1 6 4 Landings shall have a width not less than the width of the stairway or width of the doorway whichever is the greater Where a landing serves an occupant load of 50 or more doors in any position shall not reduce the landing dimension to less than one half it required width The minimum length in the direction of exit travel is 44 inches Sec 1008 1 5 5 The space between two doors in series shall be 48 inches plus the width of door swinging into the space Sec 1008 1 7 Code review for Project Id Condomiumn Address 1809 melody In Page 12 EMERGENCY ESCAPE AND RESCUE Sleeping rooms, including those within basements shall have at least one exterior emergency escape and rescue opening Such openings shall open directly into a public street, public alley yard or court Sec 1025 1 Exception 2 An exterior opening is not required in sleeping rooms provided with a door to a fire resistance rated corridor having access to two remote exits in opposite directions Emergency escape and rescue openings shall have a minimum net clear opening of 5 7 square feet Sec 1025 2 Exception The minimum clear opening on the ground level is 5 0 square feet The minimum net clear opening height shall be 24 inches The minimum net clear opening width shall be 20 inches Sec 1025 2 1 Openings shall have the bottom of the clear opening not greater than 44 inches measured from the floor Sec 1025 3 Emergency escape and rescue window openings shall be operational from the inside without the use of keys or tools Bars grills grates must not reduce the required clear area and be openable without the use of a key, tool or force greater than normal operation Sec 1025 4 Window wells shall allow the window to be fully opened and provide a minimum accessible net clear opening of 9 square feet with a minimum dimension of 36 inches Sec 1025 5 1 Window wells with a vertical depth of more than 44 inches shall be equipped with an approved permanently affixed ladder or steps Sec 1025 5 2 Code review for Project Id Condomiumn Address 1809 melody In Page 13 STAIR REQUIREMENTS Dwelling stairs Within individual dwelling units 1 A stairway must be at least 36 inches wide Sec 1009 1 Exception 1 2 The maximum rise of a step is 7 3/4 inches and the minimum run is 10 inches A nosing not less than 3/4 inches but not more than 1 1/4 inches shall be provided on stairways with solid risers where the tread depth is less than 11 inches Sec 1009 3 Exception 5 3 Provide a handrail on at least one side of stairway Sec 1009 11 Exception 2 Handrail height measured above stair tread nosing, shall be not less than 34 inches and not more than 38 inches Sec 1009 11 1 Stairways 1 The riser heights shall not be less than 4 inches or greater than 7 inches The minimum tread depth is 11 inches Sec 1009 3 The maximum variation is 3/8 inch between the largest and the smallest in a stairway flight Sec 1009 3 2 The minimum width of a stairway is 36 inches, 44 inches if the occupant load is greater than 50 Sec 1009 1 Also, check exit table above to see if minimum width is greater than 44 inches 3 Provide a handrail on each side of stairways Sec 1009 11 Handrail height measured above stair tread nosing, shall be not less than 34 inches and not more than 38 inches Sec 1009 11 1 Handrails with a circular cross section shall have an outside diameter of at least 1 1/4 inches and not greater than 2 inches or shall provide equivalent graspability Sec 1009 11 3 Handrail gripping surfaces shall be continuous without interruption by newel post or other obstructions Sec 1009 11 4 Handrails shall return to a wall guard or the walking surface or shall be continuous to the handrail of an adjacent stair flight Where handrails are not continuous between flights the handrails shall extend horizontally at least 12 inches beyond the top riser top riser and continue to slope for the depth of one tread beyond the bottom riser Sec 1009 11 5 4 Open sides of walking surfaces which are located more than 30 inches above the floor or grade below are required to have a guard Sec 1012 1 5 The minimum height is 42 inches Sec 1012 2 Within individual dwelling units Exception Guards whose top rail also serves as a handrail shall have a height not less than 34 inches and not more than 38 inches measured vertically from the leading edge of the stair tread nosing 6 Open guards shall have balusters or ornamental pattern such that a 4- inches diameter sphere cannot pass through any opening up to a height of 34 inches From a height of 34 inches above the adjacent walking surface to 42 inches above the walking surface a sphere 8 inches in diameter shall not pass Sec 1012 3 Exception 1 The triangular opening formed at the riser, tread and guardrail may be 6 inches Code review for Project Id Condomiumn Address 1809 melody In Page 14 Exception 3 Areas which are not open to the public within 1 -3, F, H, or S occupancies, balusters horizontal intermediate rails, or other construction shall not permit a sphere with a diameter of 21 inches to pass through 7 The minimum headroom clearance is 80 inches (6 ft 8 inches measured vertically from a line connecting the edge of the nosing Headroom shall be continuous to the point where the line intersects the landing below The minimum clearance shall be maintained the full width of the stairway and landing Sec 1009 2 8 Enclosed usable space under the stairs is required to be protected by 1 -hour fire resistive construction or the fire resistance rating of the stairway enclosure whichever is greater Sec 1019 1 5 9 A flight of stairs shall not have a vertical rise greater than 12 feet between floor levels or landings Sec 1009 6 STAIRWAY ENCLOSURES 1 Stairways are required to be in 2 hour fire resistive exit enclosures Sec 1019 1 Exception 4 Stairways that are not a required means of egress element only need to comply with shaft enclosure requirements in Section 707 2 Exception 7 in Section 707 2, Not required if 7 1 Does not connect more than two stories 7 3 Is not concealed 7 4 Is not open to a corridor in Group I and R 7 6 Is separated from openings to other floors by construction complying with shaft requirements 2 The openings into the exit enclosure are required to be 1 1/2 hour fire assemblies Table 715 3 Openings into enclosure are limited to those necessary for exit access to the enclosure from normally occupied spaces and for egress from the enclosure Sec 1019 1 1 Doors shall be self closing or automatic closing Sec 715 3 7 Code review for Project Id Condomiumn Address 1809 melody In Page 15 3 Exit enclosure must discharge directly to the exterior of the building Sec 1023 1 Exception 1 50 percent of the number and capacity may exit through areas on the level of discharge provided all of the following are met 1 1 There is a free and unobstructed way to the exterior that is readily visible and identifiable form the exit enclosure 1 2 The level of exit discharge is separated from areas below by construction conforming the fire resistance rating for the enclosure 1 3 The egress path from the enclosure and all portions of the level of discharge with access to the egress path are protected with an automatic sprinkler system or separated from the egress path as required for an exit enclosure Exception 2 50 percent of the number and capacity may exit through a vestibule provided all of the following are met 2 1 The area of the vestibule is separated from areas below by construction conforming the fire resistance rating for the enclosure 2 2 The depth from the exterior of the building is not greater than 10 feet and the length is not greater than 30 feet 2 3 The vestibule is separated from the remainder of the level of exit discharge by construction providing at least the equivalent of approved wired glass in steel frames 2 4 The vestibule is used only for means of egress and exits directly to the outside 4 The walls and soffits within enclosed usable spaces under stairways shall be protected by 2 hour fire resistant construction Access to the enclosed usable space shall not be directly from within the stair enclosure Sec 1019 1 5 5 If a stairway continues below the level of exit discharge an approved barrier is required at the level Directional exit signs shall be provided Sec 1019 1 6 ELEVATOR REQUIREMENTS 1 An approved pictorial sign of a standardized design shall be posted adjacent to each elevator call station on all floors instructing occupants to use the exit stairways and not to use the elevators in case of fire Sec 3002 3 3 Hoistways of elevators penetrating more than three stories shall be provided with a means for venting smoke and hot gases to the outer air in case of fire Sec 3004 1 Code review for Project Id Condomiumn Address 1809 melody In Page 16 1104 4 Multilevel buildings and facilities At least one accessible route shall connect each level, including mezzanines in multilevel buildings and facilities EXCEPTION 1 An accessible route is not required to stories and mezzanies above and below accessible levels that have an aggregate area of not more that 3,000 S F This exception does not apply to 1 1 Muliti tenant facilities of group M occupancies containing five or more tenant spaces; 1 2 Levels containing offices of health care providers (Group B or I) 1 3 passenger transportation facilities and airports (Group A -3 or B) or 1 4 buildings owned or leased by government agencies RAMP REQUIREMENTS 1 The minimum width is 44 inches If a ramp serves an occupant load of 50 or less, it may be 36 inches wide If the ramp is serving a high occupant load, check exit table above for required width Sec 1010 5 1 1016 2 Exception 2 2 If the ramp is part of the means of egress, the maximum slope is 1 12 All other ramps may have a slope of 1 8 or less Sec 1010 2 3 The rise for any ramp shall be 30 inches maximum Sec 1010 4 4 Landings shall be provided at the top, bottom, points of turning and at doors Sec 1010 6 Landings shall have a length of at least 5 feet in the direction of travel Sec 1010 6 3 Where changes in direction of travel occur at landings the landing shall be 60 inches by 60 inches minimum Sec 1010 6 4 5 The surface shall of slip- resistant materials that are securely attached Sec 1010 7 1 6 Handrails shall be per stair requirements Sec 1010 8 A rail shall be mounted below the handrail 17 to 19 inches above the ramp or landing surface Sec 1010 9 1 7 A curb or barrier shall be provided that prevents the passage of a 4 -inch diameter sphere where any portion of the sphere is within 4 inches of the floor or ground surface Sec 1010 9 2 Code review for Project Id Condomiumn Address 1809 melody In Page 17 EXIT ACCESS TRAVEL DISTANCE The maximum travel distance in Group R is 200 feet Table 1015 1 The maximum travel distance in Group S1 is 200 feet Table 1015 1 The maximum travel distance in Group S2 is 300 feet Table 1015 1 BUILDING ACCESSIBILITY 1 In addition to accessible entrances required by Sections 1105 1 1 through 1105 1 6 at least 50 percent of all public entrances shall be accessible Sec 1105 1 2 At least one accessible entrance shall be provided to each tenant dwelling unit and sleeping unit in a facility Sec 1105 1 6 3 Where parking is provided accessible parking spaces hall be provided in compliance with Table 1106 1 Sec 1106 1 4 At least one accessible route shall connect each accessible level Sec 1104 4 See exceptions 5 Accessible routes shall coincide with or be located in the same area as a general circulation path Where the circulation path is interior the accessible route shall also be interior Sec 1104 5 6 On floors where drinking fountains are provided, at least 50 percent but not less than one fountain shall be accessible Sec 1109 5 7 ADA title 3 technical assistance manual (covering public accomodations and commercial facilities) A "professional office of health care provider" is a location where state regulated professionals provides physical or mental health services to the public The ADA's elevator exemption does not apply to buildings housing the offices of a health care provider Accessible dwelling units shall be provided in accordance with Table 1107 6 1 1 ROOFING REQUIREMENTS 1 The roofing on this building is required to be Class B or better Table 1505 1 Code review for Project Id Condomiumn Address 1809 melody In An automatic sprinkler system is R- occupancy Sec 903 2 7 An automatic sprinkler system is enclosed parking garages Sec An automatic sprinkler system is located beneath other groups Page 18 AUTOMATIC SPRINKLER SYSTEMS Sec 903 If openings are not provided in each 50 feet on at least one exterior wall or there is floor area more than 75 feet from an exterior opening an automatic sprinkler system is required Sec 903 2 10 1 Openings shall have a minimum dimension of 30 inches There must be at least 20 sq ft of opening in every 50 lineal feet of wall or fraction thereof Sec 903 2 10 1 Openings must be entirely above the adjoining ground level Exception Openings below grade that lead directly to ground level by an exterior stairway or outside ramp Sec 903 2 10 1 #1 See sections 905 4 and 905 6 for required locations See section 905 7 for cabinet requirements required in fire areas containing an required throughout buildings classified as 903 2 9 required in an enclosed parking garage where Sec 903 2 9 STANDPIPE AND HOSE SYSTEMS Sec 905 Class III standpipe systems shall be installed throughout buildings where the floor level of the highest story is located more than 30 feet above the lowest level of fire department vehicle access Sec 905 3 1 FIRE ALARM SYSTEM Sec 907 A manual fire alarm system is required Sec 907 2 9, #1 Single or multiple station smoke alarms shall be installed in corridor or area giving access to each rooms used for sleeping purposes in sleeping rooms and on each floor Sec 907 2 10 1 2 Code review for Project Id Condomiumn Address 1809 melody In Page 19 LIGHT AND VENTILATION 1 Every space intended for human occupancy shall be provided with natural light The minimum net glazed area shall not be less than 8% of the floor area Sec 1205 1 and 1205 2 Any room is permitted to be considered as a portion of an adjoining room where one half of the area of the common wall is open and unobstructed and provided not less than one tenth of the floor area or 25 square feet, whichever is greater Sec 1205 2 1 Artificial light shall be provided that is adequate to provide an average illumination of 10 foot candles over the area of the room at a height of 30 inches above the floor Sec 1205 3 2 Natural ventilation of an occupied space shall be through windows, doors louvers or other openings to the outdoors Sec 1203 4 The minimum openable area to the outdoors shall be 4 percent of the floor area Sec 1203 4 1 Any room is permitted to be considered as a portion of an adjoining room where unobstructed openings are provided that have an area not less than 8% of the floor area of the interior room but no less than 25 square feet Sec 1202 3 1 1 When openings are below grade, clear space measured perpendicular to the opening shall be one and one half times the depth of the opening Sec 1203 4 1 2 3 Rooms containing bathtubs, showers spas and similar bathing fixtures shall be mechanically ventilated As per the 2003 Washington State Ventilation and Indoor Air Quality code CEILING HEIGHTS Occupiable spaces habitable spaces and corridors shall have a ceiling height of not less than 7 feet 6 inches Bathrooms toilet rooms, kitchens, storage rooms and laundry rooms shall be permitted to have a ceiling height of not less than 7 feet Sec 1208 2 Code review for Project Id Condomiumn Address 1809 melody In Page 20 WALL AND CEILING FINISH 1 Wall and ceiling finish materials are required to comply with Sec 803 5 and Table 803 5 2 Textile wall coverings shall have Class A flame spread index and shall be protected by automatic sprinklers or meet the criteria in Section 803 6 1 1 or 803 6 1 2 Sec 803 6 1 3 Carpet and similar textile materials used as a ceiling shall have a Class A flame spread index and be protected by automatic sprinklers Sec 803 6 2 4 Expanded vinyl wall coverings shall comply with the requirements for textile wall and ceiling materials Sec 803 7 5 Toilet room floors shall have a smooth, hard nonabsorbent surface that extends upward onto the walls at least 6 inches Sec 1210 1 6 Walls within 2 feet of urinals and water closets shall have a smooth, hard nonabsorbent surface, to a height of 4 feet above the floor Sec 1210 2 INSULATION NOTES 1 Insulating materials shall have a flame- spread rating of no more than 25 and a smoke developed index of not more than 450 Sec 719 2 (concealed installation) and Sec 719 3 (exposed installation) 2 Where such materials are installed in concealed spaces, the flame spread and smoke developed limitations do not apply to facings coverings and layers of reflective foil that are installed behind and in substantial contact with the unexposed surface of the ceiling wall or floor finish Sec 719 2 1 Foam plastic insulations are required to be protected Sec 2603 ADDITIONAL REQUIREMENTS For R -2 occupancy For S -1 occupancy For S -2 occupancy Floor -B 1 Occupancy- Parking Garage Vehicle barriers not less than 2 feet high are required where the difference in elevation is greater than 1 foot Sec 406 2 4 Vehicle barrier systems shall be designed to resist a single load 6 000 pounds applied horizontal Sec 1607 7 3 Note Garages accommodating trucks and buses shall be designed for that use Code review for Project Id Condomiumn Address 1809 melody In Page 21 ACCESSIBLE FACILITIES NOTE Except as noted, section numbers listed below are from ANSI A117 1 -2003 AND CHAPTER 11 OF THE 2003 INTERNATIONAL BUILDING CODE WATER FOUNTAINS AND WATER COOLERS Accessible units must comply with the following 1 Spout is to be within 36 inches of the floor Sec 602 4 2 Spout arranged for parallel approach shall be located 3 1/2 inches maximum from the front edge Units with a forward approach shall have the spout 15 inches minimum from the vertical support and 5 inches maximum from the front edge of the unit Sec 602 5 3 Spouts shall provide a flow of water 4 inches height minimum Sec 602 6 TOILET FACILITIES 1 A 60 inch diameter turning space or T- shaped space is required in the toilet room Sec 603 2 1 and 304 3 Doors shall not swing into the clear floor space for any fixture 603 2 3 See exception for rooms used for individual use 2 Water closet shall be mounted adjacent to a side wall or partition The distance from the side wall or partition to the centerline of the water closet shall be 16 to 18 in Sec 604 2 3 When the accessible water closet is not in a compartment Clearance around the water closet shall be 60 inches minimum measured perpendicular to the side wall, and 56 inches minimum measured perpendicular to the rear wall Sec 604 3 1 4 When the accessible water closet is in a compartment Wheelchair accessible compartments shall be 60 inches wide minimum measured perpendicular to the side wall, and 56 inches deep minimum for wall hung water closets and 59 inches deep for floor mounted water closets, measured perpendicular to the rear wall Sec 604 8 1 1 Compartment doors shall not swing into the minimum required compartment area Sec 604 8 1 2 Code review for Project Id Condomiumn Address 1809 melody In Page 22 5 Grab bars shall have a circular cross section with a diameter of 1 1/4 inch minimum and 2 inches maximum or shall provide equivalent graspability Sec 609 2 The space between the wall and the grab bar shall be 1 1/2 inches Sec 609 3 Grab bars shall be mounted in a horizontal position 33 inches minimum and 36 inches maximum above the floor Sec 609 4 a Side wall grab bars are required to start within 12 inches of the backwall and extend to 54 inches from the back wall (The minimum length of the bar is 42 in) Sec 604 5 1 b The rear bar shall be 24 in long minimum centered on the water closet Where space permits the bar shall be 36 in long minimum, with the additional length provided on the transfer side Sec 604 5 2 6 The top of the water closet seats shall be 17 to 19 inches above the floor Sec 604 4 7 Accessible urinals shall be of the stall type or wall hung with the rim at 17 inches maximum above the floor Sec 605 2 8 Accessible lavatories shall be mounted with the rim 34 inches maximum above the floor Sec 606 3 9 Sinks shall be 6 1/2 inches deep maximum Sec 606 5 10 Water supply and drain pipes under lavatories shall be insulated or otherwise treated to protect against contact Sec 606 6 11 Mirrors shall be mounted with the bottom edge of the reflecting surface 40 inches maximum above the floor Sec 603 3 FIRE WALL REQUIREMENTS Each opening through a fire wall shall not exceed 120 square feet The aggregate width of openings at any floor level shall not exceed 25 percent of the length of the wall Sec 705 8 Code review for Project Id Condomiumn Address 1809 melody In Page 23 If the building has a projection (overhang canopy etc) at the fire wall the fire wall shall extend to the outer edge of the horizontal projection Sec 705 5 2 Exception 1 If projection is without concealed spaces fire wall may stop at the exterior wall if the exterior wall and projection on each side of the fire wall is 1 -hour fire resistive for the depth of the projection on each side of the fire wall Exception 2 If projection has concealed space and is noncombustible fire wall may stop at the exterior wall if the projection has a one hour wall in the concealed space and the exterior wall and projection is 1 -hour fire resistive for the depth of the projection on each side of the fire wall Exception 3 If projection has concealed space and is combustible fire wall may stop at the exterior wall if the fire wall extends through the projection in the concealed space and the exterior wall and projection is 1 -hour fire resistive for the depth of the projection on each side of the fire wall If the fire wall intersects an exterior wall at less than 180 degrees, the fire resistance rating for the exterior walls on both sides of the fire wall shall have a 1 -hour fire resistance rating with 3/4 hour opening protection The fire resistance rating of the exterior wall shall extend a minimum of 4 feet on each side of the intersection Sec 705 5 1 A Code review for Project Id Condomiumn Address 1809 melody In Page 24 PEDESTRIAN WALKWAY Sec 3104 1 The pedestrian walkway shall be of noncombustible construction Sec 3104 3 Exception Combustible construction is permitted when buildings are combustible construction 2 Walkway shall be separated from the interior of buildings by fire barrier walls with a fire resistive rating of not less than 2 hours Sec 3104 5 Exceptions 1 The distance between buildings is greater than 10 feet and the walkway and both buildings have an automatic sprinkler system per NFPA 13 See exception for glass requirements 2 The distance between buildings is greater than 10 feet and the sidewalls of the walkway is at least 50% open 3 Walkway is not required to be separated when buildings are on the same lot are treated as one building per Section 503 1 3 3 The unobstructed width of pedestrian walkways shall not be less than 36 inches The total width shall not exceed 30 feet Sec 3104 8 4 The length of exit access travel shall not exceed 200 feet Sec 3104 9 Exceptions 1 If walkway has an automatic sprinkler system, length shall not exceed 250 feet 2 If both sides are at least 50 percent open, length shall not exceed 300 feet 3 If walkway has an automatic sprinkler system and both sides are open 50 percent or more, length shall not exceed 400 feet 5 Smoke and heat venting shall be provided for enclosed walkways Sec 3104 11 Code review for Project Id Condomiumn Address 1809 melody In Page 25 GLAZING REQUIREMENTS All glazing in hazardous locations is required to be of safety glazing material Sec 2406 1 Locations Sec 2406 3 1 Glazing in swinging doors except jalousies 2 Glazing in fixed and sliding panels of sliding patio door assemblies and panels in sliding and bifold closet door assemblies 3 Glazing in storm doors 4 Glazing in all unframed swinging doors 5 Glazing in doors and enclosures for hot tubs whirlpools saunas steam rooms bathtubs and showers Glazing in any portion of a building wall enclosing these compartments where the bottom exposed edge of the glazing is less than 60 inches above a standing surface 6 Glazing in fixed or operable panels adjacent to a door where the nearest exposed edge of the glazing is within a 24 -inch arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60 inches above the walking surface Exception Panels where there is an intervening wall or other permanent barrier between the door and glazing 7 Glazing in an individual fixed or operable panel other than those locations described in items 5 and 6 above, than meets all of the following conditions 7 1 Exposed area of an individual pane greater than 9 square feet 7 2 Exposed bottom edge less than 18 inches above the floor 7 3 Exposed top edge greater than 36 inches above the floor 7 4 One or more walking surfaces within 36 inches horizontally of the plane of the glazing See Exceptions 8 Glazing in guards and railings regardless of the area or height above a walking surface 9 Glazing in walls and fences enclosing indoor and outdoor swimming pools, hot tubs and spas where all of the following are present 9 1 The bottom edges of the glazing on the pool or spa side is less than 60 inches above the walking surface 9 2 The glazing is within 60 inches of the water's edge 10 Glazing adjacent to stairways, landings and ramps within 36 inches horizontally of a walking surface when the glass is less than 60 inches above the plane of the walking surface 11 Glazing adjacent to stairways within 60 inches horizontally of the bottom tread of a stairway in any direction when the exposed glass is less than 60 inches above the nose of the tread See Exceptions Code review for Project Id Condomiumn Address 1809 melody In Page 26 ATTIC REQUIREMENTS 1 Provide an access to all attic areas with a clear height over 30 inches The minimum size is 20 inches by 30 inches There must be 30 inches or more clear height above the access Sec 1209 2 Note Opening may be required to be larger if mechanical equipment is located in the attic space See the International Mechanical Code Sec 1209 3 2 Provide cross ventilation in all attic areas The net free vent area shall not be less than 1 square foot for each 150 square feet of attic area with 50% of the required ventilating area provided by ventilators located in the upper portion of the space at least 3 feet above eave or cornice vents Sec 1203 2 Exception The minimum vent area may be 1/300 if a vapor retarder having a transmission rate not exceeding 1 perm is installed on the warm side of the attic insulation and 50 percent of the required vent area is located in the upper portion of the space at least 3 feet above eave or cornice vents Is the surface sloped toward a floor drain and does the plans show a trap primer t ‘34,-1-6 Building Department Copy Contractor/ Owner Copy Reviewed by 111 Fire Department Copy PORT ANGELES FIRE DEPARTMENT PLAN REVIEW Project Name Heckman Condos at 1809 Melody Lane Address 1809 Melody Lane Plan 06 -08 Com Residential Date 2.3.2006 We have checked this plan and find that it conforms to the requirements of our codes and ordinances. 1) Separate fire sprinkler plans are required for review 2) Separate fire alarm plans are required for review 3) A KNOX locking keybox is required for the building. Contact the Fire Department at 417 -4653 for ordering information and mounting location. 4) Doors leading to rooms containing fire sprinkler riser and fire alarm control panel must be labeled. 5) Fire extinguishers in cabinets are required at each level. Only one per level is required. Location at discretion of the contractor Cabinets to be mounted no more than 5' off the floor, in a readily accessible location. NOTE Prior to the issuance of a Certificate of Occupancy, compliance with the above conditions must be met. Date .2 3 06 Fill_out COMPLETELY and in INK. Your application and site plan MUST B COMPLETE to be accepted for review If you have any questions, call PERMITS (360) 417 -4815 FAX(360)417 -4711 Applicant or Agent: l4�'� 3 orC Live Owner• ci c-, 't _'Len I�P s ��vlci ro� Address &-vl,u S ..Sf City 'w Architect /Engineer• L r v\ 1n.A2e< Contractor_\,) 4 q tr r State License 6 Address 3 7(\L ("-st( -Z( A -L City PROJECT ADDRESS S t`40-1612. LK. DESCRIPTION Lot: -'7 4 :4 Block'. �b+ CLALLAM COUNTY PARCEL NUMBER U ,�1 11 L4l.-;Z.oc-E Li Od(`Y7 Credit Card Holder Name Billing Address. Credit Card Type VISA MC TYPE OF WORK je sidential e' New Constr Re -roof Multi-family Addition Move Garage Commercial Remodel Demolition Repair Sign Other BRIEF DESCRIPTION OF THE PROJECT CEO Y 1 a?frl. r ✓t a t .1 r,, h/n 4 �L e /n 9 l -lam(. Le1 w Gj ✓'C�(F�O G �G, vl e- rye R COMMERCIAL /RESIDENTIAL Occupancy Group -Z Occupant Load Construction Type. V lA No of Stories .3 Lot Size 133 (5 Existing Sq Ft. Total lot coverage 0-R" PLANNING USE ONLY ESA /Wetland(s): Yes No SEPA Checklist required? Yes No Other VALUATION OF CONSTRUCTION In all cases, a valuation amount must be entered by the applicant. This figure will be reviewed and may be revised by the Building Division to comply with current fee schedules. Contact the Permit Coordinator at 417 -4815 for assistance PLAN CHECK FEE IF a plan check fee is due it must be submitted at the time the building permit application and construction plans are submitted All other permit fees are due at the time of permit issuance EXPIRATION OF PLAN REVIEW If no permit is issued within 180 days of the date of application, the application will expire. The Building Official can extend the time for action by the applicant up to 180 days upon written request by the applicant (see Section R105.3 2 of the International Building /Residential Code, 2003). No application can be extended more than once I hereby certify that I have read and examined this application and know the same to be true and correct. I am authorized to apply for this permit and understand that it is my responsibility to determine what permits are required not the City's, and that I must obtain such per ioi work. BUILDING PERMIT APPLICATION SIZE /VALUATION Stove 6.1%1 SF 70 /SF 7 g b (7 3:727 SF /SF I 4- 1 t -i 6 Deck SF /SF O,0 TOTAL VALUATION -1 13. I I.S. Qk7D,r'■1 Applicant: l/ A-vt 4. t— Subdivision aelawk-oLS Date FOR OFFI` Ip ONLY Date Rec. lJ� Date Approved 7 Date Issued. Zip 9 3 S ZONING K1—A-7) Gat, 4C- 39eb Cl�a Phone 6 i tL--( 5 2 Phone 3.A. L i 5- 7 o 0111 Zip 9g 3 42 Phone /,l) q <s Exp 5/3I) t Phone 3ba Lis? cl 6 7 6 51 LtM l Proposed Sq Ft. TOTAL Sq Ft. 7 Z 7 APPROVALS PLAN BLDG DPWU FIRE OTHER. ()2 70 Feet Vertical Datum NA VD 88 Horizontal Datum NAD 83/91 U a 0 2 1 roc--to 5 rrl Area Map 742 Melody Ln 724 tr. ctr C co U ti 163 This map is not intended to be used as a legal descteption. This nap /drawing is produced be the City of Port Angeles, for its own use and purposes At oth use of th ap /drawl ig shall of be th sponsibilihe of the Cih r— 1703 7 1 i 1702 LP_V_C_259ft 155 -2.2 (.1 co 3.2 o a) PG098. 8in CONC 213ft 9 8in Ct -a- -w- --)4--.------ U� 0 0o (T) J f i `1 1833 2 I� of i 1 i at Melody Ln 8in -PVC PG127 8in PVC PG126 -PG128 P,G 123 11 t i I I I}\ 1 1 I I 1 I 111 1 I AA I l I\ 1 i f 1 I I I 1 1 1 I I II \1 I IV I t (I i 1 \I I i t 1 i I 7 r\ I r 1 ri I I f f J 7 I I 1 r\ r/ 1826 r i I 1 1830 I I I 1 8 9 /8 LJ 362 8! PG100 1800) t0• 37.7:68 PG 130.5 N 721 1834 1:42z8 i t�86s� 721 or), 0 o ci /9 292 -6 366.2 PG097 810 733 Lj 4 9 -10 2 )1 0 739 z o 1__- 0 99 -8 362.2 1838 -8in P ti 1842 LINDBERG SMITH A R C H I T E C T S anu- ry 21 '006 Litt' of `'ort A[ Btu/ding Departmcnh 325 E 4th Street Port Angeles. WA )b "i62 Re. Heckman six -writ condominium To Whom It May Concern. The undersigned has provided building enclosure documents that in my professional judgment are appropriate to satisfy the requirements of Sections 1 through 10 of EHB 1848, adopted ?005 Surt,erely, i�.SiW Y SM1 '11 Akt 111'I ECTS �`'tllt n P I. ad'.ierg Smith Architects 319 south peabody suite b port angeles wa 98362 360 452.6116 fax 360 452 7064 email contact @lindarch.com www.lindarch.com SLOPE I ROCK l5 TRENCH DRAM ?BENCH DRAIN RETAINING II II f LANL CAFI WALL 1.4 c NC P6rdCMCs SIGN ON PvST �.n I LANDSCAPING z w a_ at a— 14 1 SETBACK LANDSCAPING L NC SYMBOL PAINTED ON PAVEMENT 0 0 0 D IS' -o° RED COVERED C PAWING PARKING ROCK RETAINING WALL AT PROPERLY LINE LANDSCAPING PROPERTY LINE 100' UELSTOP O TRENCH DRAIN ASPHALT DRIVEWAY CONC. WALK I r ASPHALT PARKING (6) PARKING STALLS -6° x 18' -0° MELODY LANE Ul1EELSTOP TRENCH DRAIN COVERED PARKING LANDSCAPING 24' 36' 6° DUMPSTEF ENCLOSUF J Icon P ELECTRI' EASEMEP L 1O'T0° LANDSCAPING I SLOPE DN ROCK RETAINING WALL MM VALVE WC HG P�RKING SIGN ON POST 1 3' -0° SETBACK LANDSCAPING L I NC SYMBOL PAINTED ON PAVEMENT CITY WATER LINE TRENCH DRAIN IS' o° in LANDSCAPING oc w w I I I� COVERED PARKING F LANDSCAPING T SCALE: I I ROCK RETAINING WALL AT PROPERTY LINE rvo b PROPERTY LINE 100' U1IEELSTOP ASPHALT DRIVEWAY TRENCH DRAIN COVERED PARKING TRENCH DRAIN CONC. WALK WHEELSTOP ASPHALT PARKING (6) PARKING STALLS -6° X IS' O° PROPERTY LINE 100' MELODY LANE 1 TRENCH DRAIN COVERED PARKING LANDSCAPING 24' —O" 36. C7 LANDSCAPING. DLIMPSIEf ENCLOSUF I I 'r O 150 c UNDE PROI L' LANISCAPI I 1 5E113 P ELECTRII EASEMEI' 101.0° 1 ir AI tgALL WO Vie IW r tAlve 1 0 La� I�- CO ?MOO 6014-6 8 L c oviEPV rt-ODY tftverA r I p J SO GAL. fFer I 1 1 A 1 -6s ccr 1 31 5E1I 'GK L.11,1E A____ 1 I r� 4 r -t; I tr J A '11_,\ I LL I rJ J- I YJ 1 1- 1 J I 1 J T t woo. 1 I tq t m I I ll 1 1 1 1 I I i_ a I I .\)"(p a 1 1.. I I 1 I 1 Y M A ore 1 1>t): I 1 .1 I r 1 I 1 I r 1 I 1 I I V__a I V 1 I 1 I 1 i 1 Sce AFWAS I Dovewo T (6) ?Wick* 5 '1D0' pf'EI LI 24'-0 Mkt -4pY LE. NOR purtFereg i 1 L c 1 o v FAUST FAN UNIT 'I BUILT-UP CURB PAL OF ¢)ASHING P RIDGE DUCT CHASE BELOW MEMBRANE ROOF WALK PADS ELEVATOR PENTHOUSE ROOF HATCH LAN A MINIMUM v RECEIVED MAR 1 5 2006 CITY OF PORT ANGELES BUILDING DIVISION J /.01/11 4$ 12" -I" 2' I rV�E'NAT� A$L Es 0 M.5ATN FAN s STORAGE 3' -6" 0 'I CL 286 1 CFM FAN�� O 0 44TH DUCT GHA�E 1 12nd t 3rd i SEE NOTE s i. S LVES 1 ROOF HATCH AN (TOP Fl R ONI Y) FA 9 CFM R1' TILE u SHOWER ktv 3' -O" ES LI, 'b °I 1 M.R4TW 110 A N LA W CFM FAN I VENT I 2 ,C140! E ,I I' 2"112c3" 154TH arRafat VS r CL 2068 5' -1" K412" I 3 6 1, 1, I, 74-1 8 'I ,I p CHASE ii4W'!f• co FM KITCHEN ENT oII TEMP 4 3 RECEIVED MAR 15 2006 CITY OF PORT ANGELES BUILDING DIVISION C L y- f vz e' 1 v "V 1 Floor Ceiling Assembly —The 1 hr fire -rated solid or trussed lumber joist floor- ceiling assembly shall be constructed of rte materials and in the manner specified in the individual L500 Series Floor- Ceiling Designs in the UL Fire Resistance Directory The general construction features of the floor ceiling assembly aresummarized below A. Flooring System Lumber or plywood subfloor with finish floor of lumber, plywood or Floor Topping Mixture* as specified in the individual Floor Ceiling Design. Rectangular cutout in'.flooring to accomodate the bathtub drain piping (Item 2) to be max 8 in. by 12 in. Cutout to be patched on underside of stibfloor using one layer of min 3/4 in. thick plywood or min 5/8 in. thick gypsum wallboard (Item 1C) sized to lap min 2 in',beyond edge of rectangular cutout. Diam of opening hole -sawed through patch to accomodate drain piping: (Item 2) to be°9 in. larger than outside diam of drain piping and positioned such that drain piping is centered in opening. Patch split into two pieces at opening hole -sawed for bathtub drain piping. Two pieces positioned around drain piping, with cut edges tightly butted, and screw- attached to underside of subfloor with 1 1/4 in. long Type S steel screws spaced max 6 in. OC: B. Wood Joists* Nom 10 in. deep (or deeper) lumber, steel or combination lumber and steel joists, trusses or Structural Wood C7C Members* with bridging as required and with ends firestopped. Q C. Gypsum Board* Nom 4 ft. wide by 5/8 in. thick, attached as described in the individual Floor Ceiling Design. .0 2. Drain Piping Nom 1 1/2 in. diam (or smaller) Schedule 40 cellular or solid core polyvinyl chloride (PVC) acrylonitrile butadiene styrene (ABS) or SDR17 chlorinated polyvinyl chloride (CPVC) pipe and drain fittings cemented together and provided with PVC ABS or CPVC bathtub waste /overflow fittings. The annular space shall be a min 3/8 in. to max 5/8 in. 3. Fill, Void or Cavity Material* Sealant— Min 5/8 in. depth of fill material applied within annular space, flush with both surfaces of plywood or gypsum wallboard patch. SPECIFIED TECHNOLOGIES INC SpecSeal 100,101 102 or 105 Sealant, SpecSeal LCI Sealant (o *Bearing the UL Classification Marking it System No. F -C -2156 October 20, 2000 .F Rating, -1 Hr 'jT Raft= Hr I J 1=1 I Reproduced courtesy of Underwriters Laboratories, Inc. Created or Revised: 09/01/01 Specified Technologies, Inc. Somerville, NJ (800) 992 -1180 FOD -3306 Fa- Commander Series Selectable Candela Evacuation Signals Applications The Commander Series is a low profile strobe or horn/strobe combination that offers dependable audible and visual alarms and the lowest current available. The GE3 Series 24VDC offers tamperproof field selectable candela options of 15, 30, 60, 75. and 110 candela. The 12VDC offers tamperproof field selectable candela options of 15, 30 60, and 75 candela. The Commander Series horn offers a continuous or synchable temporal three in 2400Hz and mechanical tone, a chime and whoop tone. All tones are easy for the professional to change in the field by using switches. The GE3 Series has a minimal operation current and has a minimum flash rate of 1Hz regardless of input voltage. The Commander Series is shipped with the standard 4" mounting plate which incorporates the popular Super Slide'' feature that allows the installer to easily test for supervision. The product also features a locking mechanism which secures the product to the bracket without any screws showing. The Commander also features the Checkmate Instant Voltage Verification feature which allows the installer to check the voltage drop draw and match it to the blueprint. The GE3 Series appliances are UL 464 and UL 1971 listed for use with fire pro- tective systems and are warranted for three years from date of purchase. Standard Features Nominal Voltage 12 24 VDC 24 VDC units have field selectable candela options of 15, 30, 60, 75, and 110 candela 12 VDC units have field selectable candela options of 15, 30, 60 and 75 candela GEH horn is available in 12 or 24 Volt Super Slide'" Bracket Ease of Supervision Testing Checkmate'" Instant Voltage Verification Unit Dimensions: 5' high x 4.5' wide x 2.5' deep Synchronize Strobe and/or Horn with Gentex Series Control Module (12 Volt product must use the AVSM Module) Prewire Entire System, Then Install Your Signals Lower Installation and Operating Costs Input Terminals 12 to 18 AWG Switch Selection for High or Low dBA Switch for Chime, Whoop, Mechanical and 2400Hz Tone Tamperproof Re- entrant Grill GEC3 /GES3 12 &24VDC S E R I E S Product Listings OSOVED ttttiiv :kareW.TP? Weei0..ke4A SS?i 77i BFP (City of Chicago) BS +A/MEA #285 -91 -E CSFM 7135 -0569:122 (GEC3 -24 GEH -24) 7125 -0569:123 (GES3 -24) 7125 -0569:129 (GES3 -12) 7135 0569:130 (GEC3 -12 GEH -12) FM Approved UL 464 UL 1971 Listed CAN/ULC S526-M87 Listed ULSZ7.S3406 Listed (GEC3 -24, GEH24 GEH12) Product Compliance NFPA 72 Americans with Disabilities Act (ADA) PAEM Switch for Continuous or Temporal 3 (not available on whoop tone) Surface Mount with the GSB Gentex Surface Mount Box) Silence Horn While Strobes Remain Flashing Wide Voltage Range 8 -17.5 VDC (12 Volt Models) 16 -33 VDC or FWR (24 Volt Models) Faceplate Available in Red or Off -White GEH 12 or 24 Volt Low Profile Evacuation Horn Model Number Part Number Nominal dBA GEH12 -Ft 1 EH12 -W UEH24 -R I GEH24 -W GES3 12 or 24 Volt Selectable Candela Model Number Part dumber GES3 -12WR I 904- 1235 -002 GES3 -12WW I 904 -1237 -002 ES3- 1219WR1 I 0014 -002 ES3 -12PWW 904 -002 •tit S3 -24WW S.3- 241 GEC3 12 or 24 Volt Selectable Candela Low Profile Evacuation Horn /Strobe Model Number GEC3 -12W R GEC3 -12WW GLU3-12 PWR EC3 -12PWW EL3 24V71 tt ft EC3 -24PWR EC3 -24 9047816 -002 Notes: The GE3 Series is not listed for outdoor use. Operating temperature. 32°to 120 °F (0° to 49° C). For nominal and peak current across UL regulated voltage range for filtered DC power and unfiltered (FWR [Full Wave Rectified]) power, see installation manual. 12 volt models are DC only Gentex does not recommend using a coded or pulsing signaling circuit with any of our strobe products (see Technical Bulletin Number 014). GE3 -12 Product tro a Current Ratings Candela 1 06mA 1 1 ii ml 186mi 1 237mi UL Max2 163mA I 212mA 1 331 mA I 436mA GE3 12 Product horn Current Ratings orFT n Mode Minimum Tiimtmum Regulated dBA 10ft. dBA 10ft. 12VDC Max. per UL464 per U1464 Operating 0 (HIGH) (LOW) High Setting (mA) temp 3 2400Hz temp 3 Mechanical llemp 3 Chime Lontinuous 24Z j ;;ontinuous Mechanical I ;;ontinuous Chime vvnoop Voltage 10ft. Per UL 4641 9047239 -002 I 12 VDU' I 62�'Z 904- 1241 -002 I 12 VDC 62 -82 904-1205-002 I 24 VC)C I 62 -82 964 1207 -002 I 24 DL' j 62 -82 904 1321 -002 19 -UU2 904 1322 -002 904 -1320 -002 Part Number FRominan Candela Voltage I (UL 1971) 904 -1231 -002 I 904 -1233 -002 904 -1232 -002 90472 -002 90417 -002 -002 904718 -002 Low Profile Evacuation Strobe �3ominal� Candela Voltage (UL 1971) 12 VDC 15, 30, 60, 75 12VDC 15,30,60,75 12 VDC 15,30,60,75 12 VDC: 15, 30, 60, 75 24DC 15, .$U, 60, 75, 1 24 75, 30, 60, 75"1 0 j 24 T5, 3U, 6U 7 10 24 VU(: 15, $U, 60, 7 5; -10 12 VDC 1 15,30 60 75 12 VDC 1 15,30,60,75 uC I 15, 30, 60, 75 DC l 15, 30 60, 75 1 24 ue 1- 15, 30, 60, 75, 1171 24 VDC5, 30, 60, 75, 110 I 24 15, 30, 60, 75, 1 24VDC f 15, 30, 60, 75, 1'T71 To obtain the horn/strobe current draw, add the strobe current draw and the horn current draw. IHeverberant siBA 10ft Per UL 4641 62 -82 62 -82 62 -82 62 -82 62 -82 62 -82 62 -82 62 -82 GE3-24 Product Strobe Current Ratings Candela 1 15cd 30cd I 60cd 75cd I 110cd 24 VDC 55mA 63mAj 86mA 112in1r'I 11 UL Max 1 78mA I 96mA l 137mAf 180mA 224mA GE3-24 Product horn Current Wings oA m Moode In Anechoic Room dBA @10ft. iau 100 100 166 Model designations: "W" Wall Mount "R" Red Faceplate "W" Off -White Faceplate "P' Plain (no lettering) Available with all models. These units are non returnable. "Agent" bezel also available. In Anechoic Room dBA 10ft. 100 100 1150 100 100 1 00 100 100 Minimum dBA rd 10ft. dBA G 10ft. per UL464 per UL464 (HIGH) (LOW) 76 69' I 29 (temp 3 2400R1 78 I 71' 75 I 68' I 26 temp 3 Mechanical 76 I 70' 62' I 66' I 1 a temp 3 Chime I /0° i 66' 79 I (4" 1 29 continuous 2400Hz l 81 74° 78 1 72° 26 ontinuous n7lecnamcat "I 8 0 I 72' 63' I 61' I 13 ontinuous Chime 1 70 I 66° 1 78 I 71' I 55 n oop I 82 1 89" I Regulated 24VDC Max. Operating 0 High Setting (mA) 28 25 l b 28 25 15 Oki 'Operating the horn in this mode at this voltage will result in not meeting the minimum UL everberant sound level required for public mode fire protection service. These set- tings are acceptable only for private mode fire alarm use. Use the high dBA setting for public mode application (not applicable when using the chime tone. The chime tone is always private mode). Notes: The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. 1 The listed reverberant dBA are for the Continuous Tone mode. The Temporal 3 Tone has a reverberant dBA H 10ft. per UL 464 is 77 -83 with a horn current draw of 34mA. 2 RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16 -33VDC for 24VDC units) (8 -17VDC for 12VDC units). For strobes the UL max current is usually at the minimum listed voltage (16VDC for 24VDC units) (8VDC for 12VDC units). For audibles the max current is usually at the maximum listed voltage. For unfiltered FWR ratings, see installation manual. 360".172733 .' ST OF WA L&I 08: 16:32 a.m. 08-08-2007 1/1 PAGE 131 138/137/213137 138:133 36134174729 Ii PORT ANGELES CITI' L T CITY OF PORT ANGELES LIGHT DIVISION FAX TRANSMISSION COVER SHEET Date: To: Fax: Re: Sender: af7107 labor & Industries 417-2733 Inspections Kathy Trainor Phone: 417-4724 Fax: 4174729 YOU SHOULD RECEIVE 1 PAGE, INCI.UDING THIS COVER SHEET. IF YOU DO NOT RECEIVE ALL THE PAGES, PlEASE CALL (360)417-4724 Please inspec! for: Mike, Olympic Electric 57-5303 Heckman Condos 09 E Melody Lane / ;;/ FINAL. - Top 2 units and elevator room :::ykYOU'cPK A~ q/JfJ5 6f I f1>>5I ,y rJ pj"O""" ~ ., -,. r~ ...1liIlii;;;....~ ELECTRICAL WORK PERMIT APPLICATION Jub wired by ~IcClrical Contractor a ()wner InSlallation description B-Commercial 0 Rc~iLlclllhll Electcical contractor name Liceni:ic number DaLe expires ~_e~ $ot.c.uFl..\."'\T' PllfC":3sc:r'~ mailing address 7 z. 3 -r.f"">' 'r~c.... j.\,~....:> 9s-S'13.~ IJ~~ . o New o Altered/Addition Citv ~ ~t-\'e5. F""RO"':>' S, . State ZIP 9fl3~ 2- F"~~~;;b~''iS-2 _ 8sC:,o s;.i>-'i..W\R~ J :t::'...,"'....~L L . ~f'- ~,~'l:... P-\-"'t-........ S;:) s. ...-e.......... \ ; 1 . Tclcphl:InC number 3bO- 4'5"2 - :212-=/ Premi,;es owner's n..me H"'-c.\l"'!.'-.:l C~Q""";'" "'" ~. AddrcS5 of inspectiQn ~Dq ('I"\~\OO'l' L.-iwr C i' Y ~ ll!SL _~..:>Ue.. '" S. Phone nlImber [0 schedule i~cctioR: '3f1D-'-/S2..- 1I~0 Owner as dt'Jifl<,d hy,RCWJ9.18.161:(I) ()wner will ()(t:(IPY the. srruclrtr('for tWI) yea";:; a.tkr lhi.~ dec'/rh",,] permit is finalized. (2) Owner is mqllired lo hir(! an efectJ"ical CO/lfrc/CIQr if above 5aid p/"lJpt'rly is fOl" .~ak nm( 01' lease, Atkr reading the ,lbove ~tatcmcnL I hereby certify thal [ am the owner of the above named properly or a licemcd electrical contractor, I am m,lkitlg the electrical instal- lalion (lr al\~r';lIjon in eompliant;c with the electrical hlW$., N.fl"C., RCW, Chapter 19.28., WAC. Chaplet 296-468, The City or Port An.se]e~ Municlpal Cock, and Utilil)' SpC'c.itic3ticln~;, Sign.lLturc or owner, el~dric.:l1 conrractol' 1)1' electrical adoolni.i!;trator X Date: 3/'''''101 o Cash 0 Check # 0":::' F7\\~ o Credit Card Visa Mastercard Discover Card # Expiration Date of card 7~ oV ~peC1ion fee $ 7~"IO Servlp.e. Information ubtractions Electrlca!.Lo-'11! Additions and o NO LOAD CHANGES o Baseboard KW o Furnace KW o Heat Pump Ton LAR o Fan-Wall i<W o Overhead Service Cl Temp Service D Underground Servicg Voltage ..~ Ph.seO 1!:l 3 Service Si:<:e: _,_ Feeder Size: _,~", SAi\:IE DAY INSPRC!:lON. CALL B~FORE 1:00 AM 360-417-4735 THERMOSTAT SERVICE RUUGH.IN ---n~ Approv;:<.l~ -'D:;~ ApprQ~ Ill\t~ -ApPro~"dHY FINAL "'em..", ) DITCH FEEDER '-. I)mte 0," A.pprn...~d By D~l" Appwv",<i By Inspectiun Oatc Area. Building or J:quipmcnl Jnspected Aelion Ttlkell Electrical Inspector ~. 10 ft' t-- MAR 1 6 2007 1I~0i00C: 91: :"'''01 --. 09S8 CSt;> 09>: 'ON Xl:JeJ SJINOdlJ3l3 HJ31-IH WOdeJ 02/2&/2007 10:4& 3504523498 OLYMPIC ELECTRIC PAGE 01 -"I G-~ ,.", . '. . ELECTRICAL WORKI:'ERMlT APPLICATION Jab wired by riledrleal Coo tractor 0 Owller I~M~UO" dl:llciription tr' Commerellll 0 R..ldentl.1 Elcccri~1 eontr.ctar nlme Ucen:e number t):!,1tI b:plres ;ZjZJfb ~/"~.,, OiJ'/1?#;M5/// Pure r'! &ilin. Idl:ltell '1.21'0 TL/"1~/#re:/?' ci,3 /7;f Slate ZIP z:;,,--f- /'7/7/" I 1./ ,?'. Telephone numbe( . FAX 'number ;> 1I aNew a AlteredlAddldoa ?f/h"7 -..5" 7".f"~ -.120 r.~_ ';)~~ 00 .' b,en. . I .;I!) .cY( .;'<." Premln' owaer'.lI DlmM j/JrM7/? g.d I'~r Ad~"" ~r ~.p.ell" &j J If' 0 )11'11 /17. tl17 ~ A:Z; . r r 1rr- r Pboo. aurab.. .. "bedul. 'alp."loo: 'IJ7 -(I//; 0","" os d(/lntd by RCW-J9.28.26I:(I) Ow... will oC""P)' 'he ') cr.rlf~""'" yttU'I ~r lAb .JutrlCGl pemlJll.rftna11:ed. (1) Ow,," it r'9lJl~d It/hi,., an ~/~ leal CfNWOCI()I' "abon lIJ;d propfl'ty i.J for sale. 1'fYI' or Iwe. / After teadlnJ the above ,tatament. I bmby certifY 'ltlall am 0\0 Jwner or the. ve DallIed propeR)' or I lIemlcd. electricll conlraClor. l .to makin.; t1m eleC'lrlc:al ill IAI- I....ion. or .Iteration in c;:o~li.llce willi. Ihe electrical lawl. N,E.C.. RCW. Ch r 19.28. WAC. Chapter 296-463, Th. Cil7 01 Port Ancel.. M 'lelp.1 Cod. nd Uli~ity SpacdGcatioDs. SIr..at..... or ."per, electrlclt contrattol' or ele trlclJ .d , C NO LOAD CHANGES C eaoeboard ...l r:-N C ~um... ....lKW C He.lpump -.JTon_ LAR o "an.WalI \ r:-N . ' -i SAME DAY INSPECT ROO C~h a Check # IB'6,dit Card VISl\ MllStcrcard Discover x Expiration Date ofeud ~ o Overhoad Service o Temp Service o Undergraund service EFORE 7:00 AM 360-417-4735 THERMOSfAT Valtaga .:z.of Ph_al~ Sorvloo Sl%s: 60'0 Feeder SI%s: ,. , 0.. ApPI'lIV1llI1III1, SERVICE 0_ ~~">>J FEEDER 0'. A&I~8y Action TakeD Et.ctl'lc.l Inspector /W,e,."c;D &: FINAII ,//o.pnlVNfJ DrrCH DAO APfll'OValB, Inlpe:ction C.te Area, BUilding ar Ellulpmcet Inspected 3-1-07 NO (),.JJFC r 02/26/2007 10:46 3604523498 OLYMPIC ELECTRIC PAGE 03 . . . PANEL LOAD CALCULATION PROJECT: HECKMAN CONDO lYPICAL UNIT DATE 27 -Feb-07 VOLTAGE 120/208 PHASE 1 PHASE CONNECTED LOAD DEMAND LOAD LlGHITNG & RECEPT 1458 SF 3VA = 4,374 APP CIRCUITS 2 X 1500 VA = 3,000 LAUNDRY 1 X 1500 VA = 1,500 RANGE 1 X 12000 VA = 12,000 WATER HEATER 1 X 4500 VA = 4,500 DISHWASHER 1 X 1200 VA = 1,200 DRYER 1 X 5000 VA = 5,000 31,574 FIRST 10,000 VA 10,000 REMAINDER 21,574 X 40% 8,630 SUB TOTAL 18,630 UNIT HEATERS OX 100% 0 HEAT PUMP 4160 X 100% 4,160 STRIP HEAT 10000 X 65% 6,500 CONNECTED LOAD 45,734 TOTAL DEMAND LOAD 29,290 AMPS 220 AMPS 141 2/27/2007..,8:56 AM Prepared by R. Rockett HECKMAN CONDOXLS Loadcalc Panel 02/25/2007 10:45 35045234~8 PROJECT: HECKMAN CONDO OLYMPIC ELECTRIC PANEL LOAD CALCULATION DATE 27-Feb-07 SERVICE VOLTAGE 1201208 PHASE CONNECTED LOAD 3 PHASE TYPICAL CONDO 45734 X 6 TABLE 220.84 5-7 UNITS 44% HOUSE PANEL DEMAND 62070 X 100% CONNECTED LOAD AMPS 212712001...8:56 AM Prepared by R. Rockett 336,474 935 TOTAL DEMAND LOAD AMPS DEMAND LOAD = 274,404 = 120,738 = 62,070 182,808 PAGE 02 . , , . \ 508 HECKMAN CONDOXLS SERVICE -' If) o " , w '" <[ (L HOUSE PANEL 3 s;6 4 WIRE 120/208 VOLTS 225A MAIN BREAKER SURFACE MOUNT 42 POLES BOTTOM FEED 22000 AIC MIN CIR. CIRC. CIRC. CIR. LOAD CIRCUIT DIRECTORY NO. BRKR. AB C BRKR. NO. CIRCUIT DIRECTORY LOAD 1 3P / , 1P-20A 2 FIRE ALARM / W I HANDLE LOCK 40680 ELEVATOR 3 / 1P-20A 4 5 / 175 1P-20A 6 720 RECEPTALCES 7 1p.20A 1 P.20A 8 4500 HEAT 9 2P / 1P-20A 10 11 /'30A 12 4500 HEAT 13 2P /' 14 15 /30A 16 1200 LlGHITNG 17 1 P-20A 18 19 1 P-20A 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 51600 TOTAL VA= 51,600 CURRENT 143 AMPS DIVERSITY % DEMAND VA= 62,070 DEMAND CURRENT 172 AMPS U H '"' c- u w -" w U H (L '" :>- -" o co '" '<t M N If) '<t o cD M cD '<t o H "- o o N "- cD N "- N o ENGltllEERIHG'~LEo,TO.\~ l&'lHECK\W\I CONOOJQ& A.OPl PNL 02/25/2007 10:45 3504523498 OLYMPIC ELECTRIC PAGE 04 ~.{. . ~ PANEL LOAD CALCULATION PROJECT: HECKMAN CONDO HOUSE PANEL DATE 27-FetHl7 VOLTAGE 120/208 VOLTS PHASE 3 PHASE CONNECTED LOAD DEMAND FACTOR DEMAND LOAD LIGHTING 1200 X 125% '" 1,500 RECEPTACLES THRU 10,000 720 X 100% '" 720 OVER 10,000 0 X 50% '" 0 TOTAL 720 MOTORS/COMPRESSORS LARGEST 40680 125% '" 50,850 0 X 100% '" 0 HVAC EQUIPMENT 9000 X 100% " 9,000 AND MECHANICAL SPECIFIC-USE 0 X 100% = 0 RECEPTACLES KITCHEN EQUIPMENT 0 X 65% = 0 APPLIANCES: 0 X 100% = 0 RANGES 0 X 35% = 0 MICROWAVES 0 X 51% = 0 TOTAL CONNECTED LOAD 51,600 TOTAL DEMAND LOAD 62,070 AMPS 143 AMPS 172 HECKMAN CONDO.xLS 05/11/2005 01:15 13504525177 ALL WEATHER HEATING PAGE G'Io~ ~ ~ ELECTRICAL WORK PERMIT APPLICATI .fob wired by CI Electrical Contractor DOwner EJe"ctTic:.nl contr<lctor nallle , License number DMe Expires/.... M\ \J..a+\.v-r \\eo.~-".(' ~~ f\\\\J~\\{'\,tiaili o/e(l Purchoocr'. mnillng ,ddress C' _ '-(J'-'-"""" u .3(');l I,(o~ ~. C~or<\- (\~... "lb. ZrP Q2;-;s{o;J. Telephone number FAX nurnbcr Inst:.l11:ttion description Q Commercial J4. Residential QNew o Altered! Addition L>oJ +. '5~ ..rm ~ "'* -\l '/o.lV'.~ I ~:d:s 6, "'I . // / 0'1111,1:'1' os dcfin,ed by RCW.J9.28,261:(J) Owner wW oCCllpy the struct ':/or 1'11'0 )'t?(JJ~'i nfier this electrical pcnnll is finalized. (2) Owner i.~ required in '/l"r: an elec~'ir.al cm!lrtJclor if aho"tJ said property Is for .'inte. rt!nr Qr €. Aner rcndins lhe El.bovc iltak'menl, I hereby certify t !It t a l'h7'"owncT of tJ1C B ov named property or a licertshd electrical corn-racier, I m cillg the electrical in . li'ltion or :lllerM1on in com~llQnc'C~with \e clchr;c. IIl,S:N,E.C" RCW. Chnptcr 19.28. WAC. Chapter 296:"'46S, he . or Ron Angeles Mllnicipal Code. and Utility Spceific:nions. I.. .,/ SfgnAtllrc or owner. c1'ctr nl con actor or ell!drh=al ndmlnlstrator ;,/ Date: ~Ij 0'7 AAd_Q!',:'s,lIb.\(ll.CllOJl!\ / / _KW / . T on/ LAR - /- Q Fan-WolI _ !5W Q Underground Service L SAME DAY INSPECTION, CALL BEFORE 7:00 AM 360-417-4735 / CJ Cheek # ~ Credit Card Visa Card # Mastercard Disoover - - -------....,..--------- Expiration Date of card ,Splv!ce Information CI Overhead Service o Temp Service Voltage Phase010S Service Size: Feeder SIze: ROUGH-IN / TIIERMOSTAT SERVICE OlllO ^pprav~d By "- OlllO ^IlIlTllVct1I;',Y Dill" ^T'llmvetl l:Iy / / F1NALN7 DITCH FEEDER I"~J ~6? "- I)Atc I'provcdDY7 "- nlll~ ApI7"''Y1lll 8y :, D~tc AJlprovcd hy./ fnspcction Area, Building or Equipment lni;pected E:lcctrical Oate Action Takon Inspector ,.- z,. -0 7 .A~<Iov~ ~,t.. . . ! I -l ,~,,~ . " , . . Cashier info Payment Type Check # ICash Adjustment I Application # 07- 111 /7t,8~ ~;/ANE.1 :z)p7 C.c0jA #' <!/;;';'-731;{)-7P1.3-z-z-"l3 Llc -0/'06 J 1 c> , {TV Refund Amount f 90. t:> 0 Receipt # Fee Type Posted Fee New Fee ;<~A:3o", ; 61f'./1I /t'4..A-L- (!.()N .~<L 0>1 eN (3""u-oU2S }ht;s /1 LI2t!-m;; Pm D /"0.'1- " T-S77'H75 or' p~ r-r #: 6{,- '/ '1 Amount Paid Adjustment Signature fl 'f'C /I (vJ fI ILJ LO(JJt<'It floolt -- Sfjf, f :; 7 0 ;u ~()eA-1ib'@v - 6~)f!;LJ- ol'le VJ~st~)p ODe:' e/!-S+~ ;Jp I'll I d d IY' F /OOf2 - cd, Pf-J C 0.17 e ,I/'PfJ I fj(.l/~Il ~. 7(;;0 / 8 kUJ t "lee f,p,' i C I, ell-I ~ IIUe:,! p y.)6 J /vT I - I . '" r I I' j; -, / / "-0 C -A-lJUfll -- I'\(jd ~~(J,!U}v'f>(:7;{)IV .. ,. -0a.f1-~~rv- ONe we'S.f-~I~1"" , ON f" ~;}~ t~ / J p u f? E 1. t- )00((. -- I ..;.. - I"> n J....D ~ 11- . /()Iv . c;::.Od;- 1:0/1:0 39\1d \ r!.O,;\/ J (j ',- ~ '~ , ,1 / ' 1- J 1 '+ s;/-s:,' PI'...1 lIPr.-,' It</t rij) ~ il/; _iIL,1 I I (,..) t ft, ) J !~, i,,<J j:i"C ~,(?i C h pt,.'f, 00. +-dCld(2 LtIU; I-C/~-e:A fPWflf j , i3t2iA/(PrfsJz ('" a r 19/i1/J . / 0/", r a '-<. ,,-f( '"!" "2)D-....) uvdooi2 VII) I' L 1:SlLflk'Pl? S 12'('" O,I,\w Soil fliP S, Be~f~fZ J... ,12,}l, fa G tJ./J1pS , S(Zf' 5'( () " ' ,,' 'j , 1/ ..,.... 2 rft-c;(fr-jf !~:fJ/!-f[(1'1JS,()./? JON 8 KkJ [(~ci;e;c h~~J s IAJ;!I~ )0 (j/I\.+ (IJ ;U~)~cJ !() i- J ,I ' I,:,) .f'l;J/''e-;:l S /2. eo ~o 1LT ,~ I , LRA 72,S 9NI1\13H ~3Hl\13M ll\1 OE:1:1: 9001:/TT/SO LLTS1:Sr09ET ,bOt .....;;;.0 CITY OF PORT ANGELES PUBLIC WORKS - ELECTRI(:AL DIVISION ,21 EAST 5TH STREET. PORT ANGELES. WA 98362 /,r " /,r , /' / " ,/ \, c Date 2/14/07 / i APV~lcatlon Number Application pin number Property Address ASSESSOR PARCEL NUMBER: Application type description Subdivision Name Property Use Property Zoning Application valuation 07 00000149 562542 1809 MELODY LN 06-30~14-6-2-0440-0000- ELECTRICAL ONLY /~ f,i" ,/ RESIDENTIAL HIGH DENSITY o / / Owner HECKMAN, JAMES C!GLEVA % JAMES & ASSOCIATES 1115 E FRONT ST B PORT ANGELES (360) 417~2810 ALL WEATHER HTG & COOLING 302 KEMP ST/ PORT ANGELES / (360) 452-9813/ / -----;~~~:~- ----~------;~~~;~~;~~-~~~-;~~~~~~;~~~--~t------------------- Additional desc AgLSL24WOEATHER/ 6_T_S~TATS /,1' ~ Permit pin number ' Sub Contractor ALL WEATHER HTG & OOLJN G;tNC. 1.1. Permit Fee 90,00 ft Ian .check Fee ,,, . 00 Issue Date 2/14/07 I Ilua-tion . , , , /""",," 0 Expiration Date 8/13/07 Il ~ ,J , Qty Unit Charge Per / I " Extension 1.00 35.0000 ECH Fee summary Charged Paid Credited Due - u_ - ---- uu - - u ---1-- - _u f u - - ___ __ ___ u - u_ ______ Permlt Fee Total 90 00 ,f 90.00 .00 ,00 Plan Check Total \ ,00 I .00 .00 .00 Grand Total 90.,00 I 90.00 .00 .00 ~\J i/ '\u"'> ; / \ / - / 'f / ; /' WA 98362 COMMENTS/ACTION NEEDED ~ . f -....:. .~ () ""'{) ~ t't\ t' t;) t> ~ i~ "---' 2006/AUG/01/TUE 02:21 PM CITY OF PA BLOG OEPT FAX No. 360 417 4711 P 002/002 . I ! -!------:,------------:--------_._'"--._- ___n______-------------- __~__~ ELEClRICAL WORK PERMIT APPLICATION . ~ 1 u&S s -.' I . . J ~-- i I Jo~ wired by Electrical Contractor 0 Owner IC&lallation description / P. ~!>,Ill~,ercla1 t'!:(Re,idential . ~w 0 AltetedlAddltlon 'lJ "Q 6lecttical contractor came License nwnber. Dale: E"Pires . g,liUJ . (aA",{~17ZIG-. J2,/4-,~(.it2:7<!JS ...f.vrpnas.eJ)I.Jl1a,iJhJ&...,I~>:! 1-1'73>0 C?To'/1lkr/lE'IEfl.- (14) N.c, City Stale ZIP POOLS 11-0 \tV!)-. 1(3)0 Telepho e nuin~ .' FAX n . (I ) '771- 2-// ~ 71"/ .- lLJI,<] (f {() f}1i1!lSL"(tV/(AJ: 7 '1i ~ 1c.fJ41Y71' ~et-s \ " \ "remisel owner', bame VI~/ON A ddreu' or 1"'ptl;:Ul)1l, /YJ E-i-{)C>'-I LA I--l E 0"<" /l rOIL-, nN4EL-e? Bou,DEfl.S /809 Clfy '0 ,J _6 1 ~ 0 1t-L€c.:\yZ---tC ~'Y,O__" 1- ___cJk -:t:F_2?Jj)"'__ ____ ______.'~ o Cash 0 Check # . -il= 79 { Db Cl Credit Card Yisa MllStercard Discover '. ___ _<"_"~~___~v'c....__ ____.I. ~A_,_~_9____ Card # - -... ~~AS~L~~~~L'~8o--- EXptrabon Date ' of card 10~ :IO~ -+ $"'P"';oo foe I~ Service Information Voltage i ~O IlIJO Phase B"i 0 3 . Service Size; ~MP Feeder Size: '7'00 (Y)(..fYl IH_v. I _'"J_'><- .)=__-::_~~l?~IL,s. _- n?.3..<'{o__ i /J ( \ SONlco l'uj5#~'::'...Q__~_ ]~_7._3.'-j.Q}_(j(P3'~~/,'ce . loa ServIce J -- u.;J...1Bu.L'll_O-417-4735 iTAT ,_u~__ E1fl1P?N..'1~/_~_ _ _-__2..18. t. 0_. _L:L't,3o {t:l ;2 "pproVt~ Ey SERVICE CoN O,,-,T' 7~ Approved-Dr 6Nl-' J FEEDER ^l'flrowd 6y o..\~ Al>pr<>vl'd Et~ b ~8o Electrical - -~ -. _._~- - _L --:ted Action Taken Insp~ctor - n_ ----_.- .- --- ------ - --~-- AA""'ov~'lI M,:e - - -- - ~ - -- - - .~ n -- n _n - --- n - - - -- n__ . . --- - n - -- -.- - .n u - ---- - _u -_.-. n ..._.u_.____. ..-.-.-. -- .. ..om u __.n.n.. - - - n_ -- - ------ - - -- ~ . ---- - - - -- -- - n~ --- - -- --_._- - -- -- - .- u --- .- - -- . ~J)/ . ELECTRICAL WORK PERMIT APPLICATION, .' Job wired by Electrical Contractor 0 Owner lnstallation description o Commercial esidential Electrical contractor name B,/fl-/) ELEk17Ut-- Purchaser's mailing address License number Date Expires DNew o Altered/Addition BmOEl-lie .,OJ'S '1-. ~"l ;0 c,. Tl> rr l-G ry1t~"a ,to City State ZIP fJtJ()~S~ Witt Qg?'70 Telephone number FAX number ,"1- 2-11'1- Premises owner's name '2- (/() If " B>1 f' StPt'itd: ()Ie.. \/t ~lDrv rAddress of inspection '. -I!I/~, City R.~(J~ 1W~~"f /fw~Et<fiS tAJ;/iE" /801 Phone numb Owner as defined by RCWI9.28.26/:(I) Owner will occupy the structure for two years after thi.~ electrical permit is finalized. (2) Owner is required to hire an electrical contractor if above said property is for sale, rent or lease. After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I am making the electrical instal- lation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296-46B, The City of Port Angeles Municipal Code, and Utility Specifications. ~gnatu e n owner, e'e;tt;;;;;;{) or e'~t:;;: ~:;;t:a:r Electricalll ad Additions and or subtractions D NO LOAD CHANGES D Baseboard KW D Furnace KW D Heat Pump Ton LAA o Fan,Wall KW o Cash D Check # o Credit Card Card # Visa Mastercard Discover Expiration Date of card Service Information D Overhead Service o Temp Service o Underground Service Voltage PhaseD 1 D3 Service Size: Feeder Size: SAME DAY INSPECTION, CALL BEFORE 7:00 AM 360-417-4735 ROUGH-IN Dale Approved By ~FINAL of Ob ~ / / THERMOSTAT "- Dale Approved By /' DITaI '-. Date Approved By SERVlCE Dale ApprovedBy / FEEDER Date Approved By tJL Inspection Date Area, Building or Equipment Inspected Action Taken $~ '#II CITY OF PORT ANGELES PUBLIC WORKS - ELECTRICAL DIVISION 32\ EAST 5TH STREET. PORT ANGELES. WA 98J62 Application Number Application pin number Property Address ASSESSOR PARCEL NUMBER Application type description Subd1vision Name Property Use Property Zoning App11cat1on valuation 06-00000844 Date 266780 1809 MELODY LN 06-30-14-6-2-0440-0000- ELECTRICAL ONLY 8/07/06 .1 RESIDENTIAL HIGH DENSITY o Owner Contractor NEWALL ENTERPRISES 903 STRAIT VIEW DR PORT ANGELES WA 983628476 BIRD ELECTRIC 22930 STOTTLE MEYERRD. NE SEBRING FL (360) 779-2112 Perm1t Additional desc Permit p1n number Sub Contractor Permit Fee Issue Date Expiration Date ELECTRICAL NEW RESIDENTIAL BIRD/ 600A SVC + 7 FEEDERS 84145 BIRD ELECTRIC 298 10 Plan Check Fee . . 8/07/06 Valuation 2/03/07 00 o ~ , ( Lt i\~ i.....< th !Q\! '- i ~I & \'O! ~\j\ ~~ '~J ~ ~ ~ p ~ ~~ ~ ~ t. <: Qty 7 00 1 00 Unit Charge Per 23 4000 ECH EL-RM-0-200 ADD SRV FEEDER 134 3000 ECH EL-RM-401-600 1ST SRV FEEDER Extension 163 80 134 30 Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Perm1t Fee Total 298 10 298.10 00 00 Plan Check Total 00 00 .00 00 Grand Total 298.10 298 10 .00 .00 COMMENTS/ ACTION NEEDED ELECfRICAL PERMIT INSPECfION RECORD CALL 417-4735 FOR ELECTRICAL INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLA WFUL TO COVER. INSULATE OR CONCEAL ANY WORK BEFORE IT IS INSPECTED AND ACCEPTED. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE .1, INSPEC110N TYPE DATE COMMENTS NO .5IE1/!...~ Iof:- UNI)I1-rr ()tVi-'J GENERAL COMMENTS: PW-II02." 14'961 '~ ~~ CITY OF PORT ANGELES PUBLIC WORKS - ELECTRICAL DIVISION 321 EAST 5TH STREET. PORT ANGELES. WA 911362 Application Number Application p~n number Property Address 'l;8o~ ASSESSOR PARCEL NUMBER Application type description Subdiv~s~on Name Property Use Property Zon~ng Appl~cat~on valuation 06-00000376 Date 773104 ~ELODY LN 06-30-14-1-1-0130-0000- ELECTRICAL ONLY 4/25/06 RS9 RESDNTL SINGLE FAMILY o Owner Contractor HENDRICKSON RICHARD G 1826 MELODY LN PORT ANGELES WA 983624942 BIRD ELECTRIC 22930 STOTTLE MEYERRD NE SEBRING FL (360) 779-2112 Permit Add~tional desc Perm~t pin number Sub Contractor Perm~t Fee Issue Date Exp~ration Date ELECTRICAL TEMPORARY SERVICE BIRD/ 200A TEMP SVC 75226 BIRD ELECTRIC 61 30 Plan Check Fee 4/24/06 Valuation 10/21/06 00 o " ~ C) '-t) Qty 1 00 Un~t Charge Per 61.3000 ECH EL-TEMP SRV - 101-200 SRV FDR Extension 61 30 Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 61 30 61.30 00 00 Plan Check Total 00 .00 00 00 Grand Total 61 30 61.30 .00 00 ~ ~ ~ \) U ~ COMMENTS/ACTION NEEDED \\ ELECfRICAL PERMIT INSPECfION RECORD CALL 417-4735 FOR ELECTRICAL INSPECTIONS PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE rr IS UNLA WFUL TO COVER. INSULATE OR CONCEAL ANY WORK BEFORE rr IS INSPECTED AND ACCEPTED. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE I INSPECTION TYPE DATE ACCEPTED COMMENTS I YES I NO I IlITI'H I III II IfTH_~ I CUVhK ~~K vICE I I I 7;;::.i:/ -I) ~ .Ar /) I I I I I I I [ GENERAL COMMENTS: I PW-Il02 U (4'96) CITY OF PORT ANGELES DEPARTMENT OF PUBLIC WORKS . . . . INSPECTION REPORT . . . . . . REQUEST: Date 8'- Z-l -0 Co Time 7 AVVL Received by Oe....vt,S E-. (phone. person) Location of Work to be inspected 1<S(Yi t~(ody Name of person requesting inspection ~"'vtlS t= Address of person requesting inspection Lor f Y "'- r~ Type of Inspection (circle appropriate one): Sewer Foundation Framing Chimney Plumbing Final La. VLL. 1'7Cb- 6 Phone No. iff 7 -48</"1. Permit No ~ Sewer Excav. ~ lA-k.+e.r.- ") INSPECTION NOTES: Inspected: Date ~-1.\ -0 " Remarks: ~f~e.J k," Coqoo , Time (lv:c..... 0(' { z- fJ M By.De...-<A. ,s E ' t<J I + "'- p-- ..( L., "'j e.. lo(.. w\...::r 61>0. + ~ v"-~. RESTORATION REQUIRED. . . . .. YES NO X pittloJ.1 ~Ihl& b)<.(, To.p /f-q ~ b" ~v.L--. 5f. ( (kef' CJ ~ I:JL ~ ~ '". '\3 .~ '" \() Met 0 J-y L4.VLL SURFACE RESTORATION: SURFACE TYPE: 0 Unimproved OGravel o Repaired by City o Repaired by Permittee o No Damage Found o Asphalt 0 PCC 0 Other Work Order # So '7 <( &' - 23 S o COMPLETE o INCOMPLETE (Continue on reverse side if necessary) STREET SUPERINTENDENT (DATE)