Loading...
HomeMy WebLinkAbout1716 S O St - Building J ~ o Carnival 0 Commercia' , . ELECTRICAL WORK PERMIT APPLICATION ,,0 Request Inspection i ,,' C_ ~eSidenrial 0 Residential Maiol. 0 Signs 0 Thermostat a Telecom. .~ectrical Contractor CJ Annual Permit CJ Alum ~~~..~.. c" ","" .. ~~1i " '".: o Owner ~....-;;:;.....:Jo'" Job wired hy ~ectrical Contractor 0 Owner rnstallation description -,U tl!f/ c:.- #i?wr-C ."5 e:- 4t;/ V- rv iL . \ /) / Licens~ number ... ii." t:..l.? I>i.~l:~*" (y~SC:~ Purchaser's mailing address / <;.-=;; 2. 7J:1-.r~ c,:z.t Cit~ .V-zpt/t'/r? Tel pno.nc number G IrTt:"lfr ;It;":) Slate 21 P r; C; t'Srif:.-. EA.X number ,_ " g-q: ?/ C' - Premise> owner's name ~ . rJP.~ f;lh/ (. j:)rel' Address or iU5pfifioll I'llt!" '0' s, C;'YP /1 L' / o Cash 0 Check # l hereby certify that I am the owner of the above named property or a licensed electrical contractor (or the firm's authorized agent) and am making the electrical installation or alteration in compliance with the electrical law. Chapter 19.28 RCW, redi t Card )Q..'isa Mastercard Discover Signature or Card# P-AL~::;//~ contractor or electrical :administrator Expiration Date of card x WALLS [nsulation Only '\ CEILING , Insulation Only Dille Apprond By CO\,'Cr D:;l~ "'Jlflro~~1i 13~ TIfERMOSTAT DalC Dale _"pprr...od By SERVICE 3h'3/", c. A-r...n , D.lef Approval 8)' App'o~l:d. fly Cover Appm~cd B~ DITCH FErnER o-..tc ~~~BY Dille ....r~ro'."lJ ny Electrical Load Additions and or subtractions o NO LOAD CHANGES o Baseboard KW o Furnace KW a Heat Pump Ton LAR a Fan-Wall K:lN o Overhead Service o Temp Service o Underground Service Service Information VOllage/ ~Z-r/D Phasekf-, 03 Service Size' _ ~J1 Feeder Size:' ~ /l ~~ 3/;" 1"0 l ./ ~d :/ I t ( Inspcction Aren, Building or Equipment Inspected Action Tilkcn Electrical D~te Inspector - 312..1 ..HYc ~n/.L/..),.6c.; h ..:ff::.c 4P _1.LO IiPP. l!l.~ . - 2 - ),'3 .-.1/(p /1 tV.IJt-- A,P .4z-Q I I . , . . , 809 La 90 9~ J8V\! Apr 13 06 07:54a p.1 " ELECTRICAL WORK PERMIT APPLICATION ~equest Inspection ~ ' . I'" ......, T:::;.}' ~ectrjCal Contractor u Owner ~~.....:;<'" CJ Annual Permit 0 Alarm 0 Carnival 0 Commercial 1-/~-Ob I:l Residential 0 Residential Maint. Cl Signs 0 Thermostat CJ Telecom. Job ",ired by o Electrical Contractor 0 Owner Ins lallation description Electrical contractor n!IPc i2. W 6c;G/co.<- Purchascr's mailing address /c,,-3L.- ~~ City 5~tf{w-r I2-J;a;;;&t'5C3 tA//~ h~hC C-u~,c ~ State ZIP vt.41- <7 J:> r Z- FAX nu'b' ~ e:; / (;> <f .. Telephone number 77( pre~'s hh/M-C- ~ Address of inspection /7/b {7 5:r- C;'y /~ ~ >(SU:r-r:~ =Z-C:;7 I hereby certify that I am the owner of the above named property or a licensed electrical contractor (OT the finn's authorized agent) and am making the electrical installation or alteration in compliance wilh the electrical law. Chapler 19.28 RCW. o Cash 0 Check # Credit Card @ Mastercard Discover Card# -t?LY__-J'-5:tt.::? ___-____ x ~nsp;~ ~e>D ,,- WALLS " lnsulation Only Dll~ App,,",vtd By Cover Dlte AJ>p'ovcd By Expiration Date of card ,,- CEllJNG Insu\C1tiOrl Only Dal~ Approv;d By Cover Date Approved By " ,,- TIlERMOSTAT " Dale Appro"cd ny DITCH "- D..te Approved by ,,- SERVICE " Dale Approved By FEEDER Date ^?Jl'l'Ovcd By Electrical Load Additions and or subtractions 1:1 NO LOAD CHANGES o Baseboard KW o Furnace KW o Heat Pump _ Ton _ LAA o Fan-Wall KW Service Information VOl1agjf ~ z...~D Phase, 103 Service Size: ~/1 Feeder Size: 'Z?1J If- I:J Overhead Service o Temp Service o Underground Service Inspeclion Area, Building or Equipment Inspected Action Taken Electrical Date Inspector L//.. // L. /'i-A A-, ~ A. C) // / / . AcO '-f /; 3 jf) {, CITY OF PORT ANGELES DEP ARTMENT OF COMMUNITY DEVELOPMENT - BUILDING DNISION 321 EAST 5TH STREET, PORT ANGELES, WA 98362 lasered CED 06-00000073 Date 937747 1716 0 ST 06-30-00-4-4-0280-0000- FRED GANCEAU RES MANUFACTURED HOME 2/02/06 Application Number Applicat~on p~n number Property Address ASSESSOR PARCEL NUMBER: Tenant nbr, name Appl~cation type descr~pt~on Subdivision Name Property Use Property zon~ng . . . Application valuation RS9 RESDNTL SINGLE FAMILY 66314 Owner Contractor EAGLE'S LAIR LMTD PARTNERSHIP PO BOX 798 SNOQUALMIE WA 980650798 OWNER Other struct ~nfo . TOTAL % LOT COVERAGE EXISTING LOT COVERAGE LOT SIZE PROPOSED LOT COVERAGE TOTAL LOT COVERAGE 23.00 1. 00 9000.00 2032.00 2032.00 Permit BL MANUFACTURED HOME Additional desc Permit pin number 69674 Permit Fee 230.00 Plan Check Fee .00 Issue Date 2/02/06 Valuat~on 66314 Expiration Date 8/01/06 Qty Un~t Charge Per Extension BASE FEE 230.00 Perm~t BUILDING PERMIT -RESIDENTIAL Add~t~onal desc Permit pin number 69666 Permit Fee 249.75 Plan Check Fee 99.90 Issue Date 2/02/06 Valuation 12314 Expiration Date 8/01/06 Qty Un~t Charge Per Extension BASE FEE 95.75 11.00 14.0000 THOU BL-2001-25K (14 PER K) 154.00 Permit . . . . . Additional desc . Perm~t p~n number Permit Fee Issue Date Exp~rat~on Date PLUMBING PERMIT 69682 72.00 2/02/06 8/01/06 Plan Check Fee Valuation .00 o Qty Un~t Charge Per Extension 50.00 7.00 15.00 BASE FEE 1.00 7.0000 ECH PL- EA. INSTALL WATER PIPE 1.00 15.0000 ECH PL- EA. BLDG SEWER Spec~al Notes and Comments Address numbers shall be plainly v~s~ble from the street. Address numbers shall be a m~nimum of s~x ~nches high and be f1t+ALtD ?/2t;; ftb ~ ~ --1 ...... ~\' -F \)' \ ) -=::: ~ Separate Permits are required forelectncal work, SEPA, Shoreline, ESA, utilities, pnvate and public Improvements. This permit becomes null and void If work or construction authonzed IS not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last inspection I hereby certify that I have read and examined this application and know the same to be true and correct. All provIsion of laws and ordinances governing this type of work Will be complied with whether specified herein or not The granting of a permit does ot presume to give authonty to violate or cancel the provisions of any state or local law regulating construction or the performance f construction. ;!:,,{'f2 ff~ ;<-;z..~6 Signature of Contractor or Authorized Agent Date Signature of Owner (If owner IS builder) Date T \Pohcies\1102_15 buildIng permIt InspectIOn record05 wpd [1/4/2005] CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY DEVELOPMENT - BUILDING DNISION 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Applicat10n Number . . . . . 06-00000073 App11cation pin number 937747 Page Date 2 2/02/06 Spec1al Notes and Comments of contrasting color from the background. All homes in new subdiv1sions that are outside of the F1re Department four-m1nute response area shall be equ1pped with residential f1re sprinkler systems that comply with the International Fire Code (IFC) and National Fire Protection Assoc1ation (NFPA). 01/30/2006 01:48 PM SROBERDS --The proposal will result in the placement of a new mfg home 1n the RS-9 for total lot coverage of 23%. No land use issues are noted. Electr1cal load calculat10ns and elctrical perm1ts are required. Electrical connection fee of $410.00. U/g service form pole at s/e corner of lot. 01/24/2006 04:21 PM GMCLAIN ---------------------------- Sidewalk to City standards along "0" Street requ1red for school walk1ng route. Sanitary sewer connection inspection is required by Public Works prior to back fill of ditch. 24 hour advance notice 1S required. Construct driveway and Sidewalks to C1ty Standards. No concrete with exposed aggregate allowed in the C1ty road r1ght of way. An 1nspection by Public Works Engineer1ng is requ1red pr10r to prour1ng concrete. Other Fees SEWER SYSTEM DELV CHARGE STATE SURCHARGE PW WATER SYSTEM USE FEE 870.00 4.50 1200.00 Fee summary Charged Paid Cred1ted Due ----------------- ---------- ---------- ---------- ..--------- Permit Fee Total 551.75 551.75 .00 :00 plan Check Total 99.90 99.90 .00 .00 . Other Fee Total 2074.50 2074.50 .00 .00 Grand Total 2726.15 2726.15 .00 .00 Separate Permits are required for electncal work, SEPA, Shoreline, ESA, utilities, private and public Improvements. This permit becomes null and void If work or construction authorized IS not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All proviSions of laws and ordinances governing this type of work will be complied With whether specified herein or not. The granting of a permit does not presume to give authOrity to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Signature of Contractor or Authorized Agent Date Signature of Owner (If owner IS builder) Date T \Pohcles\1102_15 bUIldIng perrm! InspectIOn record05 wpd [1/4/2005] BUILDING PERMIT INSPECTION RECORD CALL 417-4815 FOR BUILDING INSPECTIONS CALL 417-4735 FOR ELECTRICAL INSPECTIONS CALL 417-4807 FOR PUBLIC WORKS UTILITIES PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE IT IS UNLA WFUL TO COVER, INSULA TE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED COMMENTS YES NO FOUNDATION: FOOTINGS /Pe>v~+{,(1Vl 1f"1/~'- -:::/7-v ~~''I0~ry~ WALLS 3 ! 7A./. (b(, Jk FOUNDATION. (DRAINAGE I DOWN SPOUTS) ? /'l-IJ--/q.. :riA...; t1fr(/J Pe, PIERS POST HOLES (POLE BLDGS ) PLUMBING Mv,ttk,f. ~'2J-~~ Tc- UNDER FLOOR I SLAB ROUGH-IN WATER LINE (METER TO BLDG) "3[t.t,(oc. J"l-u GAS LINE BACK FLOW I WATER AIR SEAL WALLS CEILING I FRAMING JOISTS I GIRDERS SHEAR W ALUHOLD DOWNS WALLS I ROOF I CEILING - . , DRYWALL (INTERIOR BRACED PANEL ONLY) 14/'2.4/0" (/Iv 1I~..s- /0 G.. .J L.t/ T-BAR "I INSULATION SLAB W ALL I FLOOR I CEILING MECHANICAL HEAT PUMP I FURNACE 1 DUCTS GAS LINE WOOD STOVE I PELLET I CHIMNEY COMMERCIAL HOOD I DUCTS MANUFACTURED HOMES FOOTING I SLAB 21d- -r / ()(P ,J~ BLOCKING & HOLD DOWNS 3//J/t:76 d~ . SKIRTING PLANNING DEPT SEPARATE PERMIT #'s SEPA P ARKING/LIGHTING ESA LANDSCAPING SHORELINE FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCYIUSE RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED YES NO ELECTRICAL - LIGHT DEPT 417-4735 ELECTRICAL LIGHT DEPT CONSTRUCTION R W 1 PWI CONSTRUCTION - R W ENGINEERING 417-4807 PW 1 ENGINEERING FIRE 417-4653 FIRE DEPT PLANNING DEPT 417-4750 J J PLANNING DEPT BUILDING 417-4815 J/)(/~ l/k/ BUILDING ~ ~ 3 VJ -t - -r~ :t 7- ~ ~~ ~ o " ~ ' T \Pohcles\1102_15 bUlldmg permIt mspectlon record05 wpd [1/4/2005] PREPARED 5/25/06, 10 59:56 CITY OF PORT ANGELES ADDRESS TENANT, NBR CONTRACTOR OWNER PARCEL APPL NUMBER 1716 0 ST FRED GARCEAU INSPECTION TICKET INSPECTOR: JAMES L LIERLY PAGE DATE 13 5/25/06 SUBDIV EAGLE'S LAIR LMTD PARTNERSHIP 06-30-00-4-4-0280-0000- 06-00000073 RES MANUFACTURED HOME PHONE PHONE 01 2/27/06 2/27/06 PERMIT: BLM 00 BL MANUFACTURED HOME REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BUILDING FOUNDATION FOOTING TIME 08 00 02/27/2006 09.59 AM DYASUMUR --------------------------- FRED 02/27/2006 02 21 mono slab for manf BUILDING BLOCK AND 03/15/2006 10 36 FRED 460-7390 03/16/2006 04:09 PM JLIERLY ---------------------------- BUILDING FOUNDATION FOOTING TIME 08.00 * OVERRIDE TAKEN BY DYASUMUR DATE: 03/22/06 TIME. 15 23:22 03/22/2006 03:22 PM DYASUMUR --------------------------- FRED 460-7390 WANTS AM INSPECTION, WANTS TO POUR AFTERNOON 03/23/2006 04 35 PM JLIERLY ---------------------------- BUILDING FOUNDATION WALL 03/24/2006 04:16 PM JLIERLY ---------------------------- 03/24/2006 04 17 PM JLIERLY ---------------------------- BUILDING DOWN SPOUT DRAINS 03/24/2006 04:16 PM JLIERLY ---------------------------- 03/24/2006 04.17 PM JLIERLY ---------------------------- BUILDING FTG/WALL TIME 13:00 03/28/2006 01.49 PM JLIERLY ---------------------------- garage foot1ng and wa11s/)11 03/28/2006 01 50 PM JLIERLY ---------------------------- BUILDING DOWN SPOUT DRAINS TIME. 13:00 03/24/2006 02:34 PM DYASUMUR --------------------------- FRED 460-7390 03/28/2006 01 48 PM JLIERLY ---------------------------- ths1 1nspect1on was complete on the 24th due to tra1n1ng on the 27th and 28th/)11 RV PUBLIC WORKS FINAL AP 05/19/2006 09:30 AM IE 05/19/2006 09.33 AM BL99 01 ~~13~_ L BUILDING FINAL TIME ~ FRED 460-7390 OS/24/2006 11:50 AM DYASUMUR --------------------------- --------------------- -- --------------------------------------------------------------------- BL1 BLBT 01 BL1 BL2 DSD BLFW 01 DSD PW99 01 3/16/06 3/16/06 02 3/23/06 3/23/06 JLL AP JLL AP JLL AP JLL AP JLL AP JLL AP JLL AP PM JLIERLY ---------------------------- home/) 11 TIEDOWNS TIME: 13.00 AM DYASUMUR --------------------------- RVESS RVESS 13:00 TYP/SQ PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL REQUESTED INSP DESCRIPTION COMPLETED RESULT RESULTS/COMMENTS 01 3/24/06 3/24/06 BL9 01 4/06/06 JLL BUILDING SHEARWALL 4/06/06 AP 04/06/2006 08:50 AM PBARTHOL --------------------------- c11nt 477-9600 04/06/2006 04 26 PM JLIERLY ---------------------------- BL9 02 4/18/06 JLL BUILDING SHEARWALL 4/19/06 DA 04/18/2006 08:12 AM PBARTHOL --------------------------- CLINT 477-9600 04/19/2006 09 12 AM JLIERLY ---------------------------- wedge anchors are not allowed 1n bp or abp/ f1n1sh fram1ng 02 3/24/06 3/24/06 ----------------------------------- CONTINUED ONTO NEXT PAGE ----------------------------------- 3/24/06 3/24/06 01 3/29/06 3/24/06 5/18/06 5/19/06 PREPARED 5/25/06, 10 59 56 CITY OF PORT ANGELES INSPECTION TICKET INSPECTOR JAMES L LIERLY PAGE DATE 14 5/25/06 ADDRESS TENANT, NBR CONTRACTOR OWNER PARCEL APPL NUMBER- 1716 0 ST FRED GARCEAU SUBDIV: EAGLE'S LAIR LMTD PARTNERSHIP 06-30-00-4-4-0280-0000- 06-00000073 RES MANUFACTURED HOME PHONE PHONE TYP/SQ REQUESTED COMPLETED INSP RESULT DESCRIPTION RESULTS/COMMENTS BLDR 02 on return wall remove gwb/Jll BUILDING DRYWALL IBWP 04/21/2006 11 15 AM PBARTHOL FRED G 460-7390 04/25/2006 08 12 AM BUILDING DRYWALL IBWP 04/25/2006 08 03 AM CLINT 477-9600 04/25/2006 04 21 PM JLIERLY ---------------------------- ~ BUILDING FINAL TIME 13 00 FRED 460-7390 OS/24/2006 11:52 AM DYASUMUR --------------------------- ------------------------ ----------------------------------------------------------------------- 4/25/06 4/25/06 JLL AP JLIERLY ---------------------------- TIME 13 00 DYASUMUR --------------------------- BLDR 01 4/24/06 4/25/06 JLL AP BL99 01 5/25/06 It PERMIT: PL 00 PLUMBING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 01 3/16/06 3/16/06 JLL AP TIME 13 - 00 DYASUMUR --------------------------- PL6 PLUMBING WATER SUPPLY 03/15/2006 03 34 PM FRED 460-7390 5/25/06 -ttf ~~~~i~gO~IN~~:09TI~~ i~I~~LY ---------------------------- ., FRED 460-7390 OS/24/2006 11:51 AM DYASUMUR ------------------------- ------~~~~~~-~~~:~::-~~-~~:::-~------------------------------------- PL99 01 PREPARED 4/25/06, 13 00:41 CITY OF PORT ANGELES ADDRESS TENANT, NBR: CONTRACTOR OWNER PARCEL APPL NUMBER: 1716 0 ST FRED GARCEAU PAGE DATE 8 4/25/06 INSPECTION TICKET INSPECTOR JAMES L LIERLY EAGLE'S LAIR LMTD PARTNERSHIP 06-30-00-4-4-0280-0000- 06-00000073 RES MANUFACTURED HOME 01 4/06/06 4/06/06 PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL9 BL9 BLDR 01 02 4/18/06 4/19/06 JLL AP JLL DA JLL AP BUILDING SHEARWALL 04/06/2006 08 50 AM cl1nt 477-9600 04/06/2006 04:26 PM BUILDING SHEARWALL 04/18/2006 08 12 AM CLINT 477-9600 04/19/2006 09 12 AM wedge anchors are not on return wall remove BUILDING DRYWALL IBWP 04/21/2006 11 15 AM FRED G 460-7390 04/25/2006 08:12 AM BUILDING DRYWALL IBWP 04/25/2006 08 03 AM CLINT 477-9600 ~ -------------------------------------- COMMENTS BLDR 02 4/24/06 4/25/06 ~ SUBDIV PHONE PHONE PBARTHOL --------------------------- JLIERLY ---------------------------- PBARTHOL --------------------------- JLIERLY ---------------------------- allowed 1n bp or abp/ f1n1sh fram1ng gwb/J 11 PBARTHOL JLIERLY ---------------------------- TIME. 13:00 DYASUMUR --------------------------- AND NOTES -------------------------------------- PREPARED 4/24/06, 12-03 04 CITY OF PORT ANGELES INSPECTION TICKET INSPECTOR JAMES L LIERLY PAGE DATE 8 4/24/06 ADDRESS TENANT, NBR CONTRACTOR OWNER PARCEL APPL NUMBER 1716 0 ST FRED GARCEAU SUBDIV EAGLE'S LAIR LMTD PARTNERSHIP 06-30-00-4-4-0280-0000- 06-00000073 RES MANUFACTURED HOME PHONE PHONE PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL9 01 4/06/06 4/06/06 JLL AP PBARTHOL --------------------------- BLDR 01 BUILDING SHEARWALL 04/06/2006 08 50 AM cllnt 477-9600 04/06/2006 04-26 PM BUILDING SHEARWALL 04/18/2006 08 12 AM CLINT 477-9600 04/19/2006 09:12 AM wedge anchors are not on return wall remove ~L BUILDING DRYWALL IBWP 04/21/2006 11 15 AM PBARTHOL FRED G 460-7390 ------------------------ ------------ COMMENTS AND NOTES -------------------------------------- JLIERLY ---------------------------- BL9 02 4/18/06 4/19/06 JLL DA PBARTHOL --------------------------- JLIERLY ---------------------------- allowed In bp or abp/ flnlsh framlng gwblJ 11 4~t;; PREPARED 4/18/06, 13 37 15 CITY OF PORT ANGELES INSPECTION TICKET INSPECTOR: JAMES L LIERLY PAGE DATE 8 4/18/06 ADDRESS TENANT, NBR. CONTRACTOR OWNER PARCEL APPL NUMBER 1716 0 ST FRED GARCEAU SUBDIV EAGLE'S LAIR LMTD PARTNERSHIP 06-30-00-4-4-0280-0000- 06-00000073 RES MANUFACTURED HOME PHONE PHONE PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL9 01 4/06/06 JLL 4/06/06 AP BUILDING SHEARWALL 04/06/2006 08 50 AM PBARTHOL --------------------------- c11nt 477-9600 04/06/2006 04:26 PM JLIERLY ---------------------------- BUILDING SHEARWALL 04/18/2006 08 12 AM PBARTHOL --------------------------- CLINT 477-9600 BL9 02 ~~ COMMENTS AND NOTES -------------------------------------- ~ lJ~i MJc~S ~G ~ ~~6 fi~t~ ~ ~~~_. PREPARED 4/06/06, 12 07-13 CITY OF PORT ANGELES INSPECTION TICKET INSPECTOR JAMES L LIERLY PAGE DATE 9 4/06/06 ADDRESS TENANT, NBR CONTRACTOR OWNER PARCEL APPL NUMBER 1716 0 ST FRED GARCEAU SUBDIV: EAGLE'S LAIR LMTD PARTNERSHIP 06-30-00-4-4-0280-0000- 06-00000073 RES MANUFACTURED HOME PHONE PHONE PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL9 01 ~~ BUILDING SHEARWALL 04/06/2006 08 50 AM cl~nt 477-9600 PBARTHOL --------------------------- -------------------------------------- COMMENTS AND NOTES -------------------------------------- PREPARED 3/24/06, 16 16 58 CITY OF PORT ANGELES ADDRESS TENANT, NBR CONTRACTOR OWNER PARCEL APPL NUMBER 1716 0 ST FRED GARCEAU INSPECTION TICKET INSPECTOR JAMES L LIERLY PAGE DATE 1 3/24/06 SUBDIV EAGLE'S LAIR LMTD PARTNERSHIP 06-30-00-4-4-0280-0000- 06-00000073 RES MANUFACTURED HOME PHONE PHONE PERMIT: BLM 00 BL MANUFACTURED HOME REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL1 01 2/27/06 JLL 2/27/06 AP BLBT 01 3/16/06 JLL 3/16/06 AP BL1 02 3/23/06 JLL 3/23/06 AP BUILDING FOUNDATION FOOTING TIME 08:00 02/27/2006 09 59 AM DYASUMUR --------------------------- FRED 02/27/2006 02 21 mono slab for manf BUILDING BLOCK AND 03/15/2006 10 36 FRED 460-7390 03/16/2006 04 09 PM JLIERLY ---------------------------- BUILDING FOUNDATION FOOTING TIME 08 00 * OVERRIDE TAKEN BY DYASUMUR DATE 03/22/06 TIME. 15:23,22 03/22/2006 03 22 PM DYASUMUR --------------------------- FRED 460-7390 WANTS AM INSPECTION, WANTS TO POUR AFTERNOON 03/23/2006 04 35 PM JLIERLY ---------------------------- BUILDING FOUNDATION WALL 03/24/2006 04 16 PM JLIERLY ---------------------------- BUILDING DOWN SPOUT DRAINS 03/24/2006 04 16 PM JLIERLY ---------------------------- PM JLIERLY ---------------------------- home/) 11 TIEDOWNS TIME 13:00 AM DYASUMUR --------------------------- ::::: .~ -------------------------------------- COMMENTS AND NOTES -------------------------------------- PREPARED 3/23/06, 14 21 39 CITY OF PORT ANGELES ADDRESS TENANT, NBR CONTRACTOR OWNER PARCEL APPL NUMBER: 1716 0 ST FRED GARCEAU INSPECTION TICKET INSPECTOR JAMES L LIERLY 10 3/23/06 PAGE DATE SUBDIV- EAGLE'S LAIR LMTD PARTNERSHIP 06-30-00-4-4-0280-0000- 06-00000073 RES MANUFACTURED HOME PHONE PHONE PERMIT: BLM 00 BL MANUFACTURED HOME REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL1 01 2/27/06 JLL 2/27/06 AP BLBT 01 3/16/06 JLL 3/16/06 AP BL1 02 ~ ~ BUILDING FOUNDATION FOOTING TIME 08 00 02/27/2006 09-59 AM DYASUMUR --------------------------- FRED 02/27/2006 02 21 mono slab for manf BUILDING BLOCK AND 03/15/2006 10:36 FRED 460-7390 03/16/2006 04 09 PM JLIERLY ---------------------------- BUILDING FOUNDATION FOOTING TIME: 08-00 * OVERRIDE TAKEN BY DYASUMUR DATE 03/22/06 TIME: 15:23:22 03/22/2006 03 22 PM DYASUMUR --------------------------- FRED 460-7390 WANTS AM INSPECTION, WANTS TO POUR AFTERNOON PM JLIERLY ---------------------------- homelJ 11 TIEDOWNS TIME 13:00 AM DYASUMUR --------------------------- -------------------------------------- COMMENTS AND NOTES -------------------------------------- PREPARED 3/16/06, 13'45 39 CITY OF PORT ANGELES INSPECTION TICKET INSPECTOR JAMES L LIERLY PAGE DATE 5 3/16/06 ADDRESS TENANT, NBR: CONTRACTOR OWNER PARCEL APPL NUMBER 1716 0 ST FRED GARCEAU SUBDIV EAGLE'S LAIR LMTD PARTNERSHIP 06-30-00-4-4-0280-0000- 06-00000073 RES MANUFACTURED HOME PHONE PHONE PERMIT: BLM 00 BL MANUFACTURED HOME REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL1 01 2/27/06 2/27/06 JLL AP BUILDING FOUNDATION FOOTING TIME. 08 00 02/27/2006 09 59 AM DYASUMUR --------------------------- FRED 02/27/2006 02 21 mono slab for manf BLBT 01 ~6 0 ~ BUILDING BLOCK AND 03/15/2006 10:36 FRED 460-7390 ------------------------ ---------------------------------------------------------------------- PM JLIERLY ---------------------------- homelJll TIEDOWNS TIME: 13'00 AM DYASUMUR --------------------------- PERMIT: PL 00 PLUMBING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS PL6 01 ~16 06 1(2 PLUMBING WATER SUPPLY 03/15/2006 03:34 PM FRED 460-7390 ----------- -------------------------- COMMENTS AND NOTES -------------------------------------- TIME 13 00 DYASUMUR --------------------------- PREPARED 2/27/06, 13,08 14 CITY OF PORT ANGELES INSPECTION TICKET INSPECTOR. JAMES L LIERLY PAGE DATE 5 2/27/06 ADDRESS TENANT, NBR, CONTRACTOR OWNER PARCEL APPL NUMBER 1716 0 ST FRED GARCEAU SUBDIV EAGLE'S LAIR LMTD PARTNERSHIP 06-30-00-4-4-0280-0000- 06-00000073 RES MANUFACTURED HOME PHONE PHONE PERMIT: BLM 00 BL MANUFACTURED HOME REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL1 01 ~ JLL ~'\ BUILDING FOUNDATION FOOTING TIME, 08 00 02/27/2006 09 59 AM DYASUMUR --------------------------- FRED -------------------------------------- COMMENTS AND NOTES -------------------------------------- ~iANf . t\t'1 s c.... ~ Fill out COMPLETELY and in INK. Your applIcatiOn and SIte plan :M:DST COlvIPLETE Ie be aCLepLeu 1'01 1 t-vicV\. If you have any questions, ~~11 PERMITS (360) 417-4815 FAX(360)417-4711 l'\ ~()IU'l \'; ~:--.. - -~/I '-....: ,:... r'- .,., fJ (~<~.1) ~;;-~ ~,"TO. ~"... ';:t\h,,-.:;""- u- ~';.~~ - -, ~-~"- , .... - ~--,...,"- ~ -.- I '''~/ BUILDING PERMIT - APPLICATION ApplIcant or Agent: F'""e..d Gr G.<A..~ Phone </?eJ- 7 .3 ~ 0 O\vner .,..5d..~ -L Phone, Address / ~ 'I !I-l.,J,., ,;1-< h1 .ed CIty fJ;r ~~~7 w.1- , ZIp: 9? j1~d- ArclutectlEngmeer. ContractollaJkl~?t ,:r.~.,.; {' nrz c,/ Address&'~ !It~t;/~:VJ J?d PROJECT ADDRESS } 7 /{; 0- ~T LEGAL DESCRIPTION- Lot :2 ~ Phone' State LIcense tII~ I~p COb7C fExp .p,/; tjIJ t CIty ,i?r-T~~~ ~ kJ A- Phone4'&c- 7 3 9 D ZIp' 9r3 t-r?- ZONING: Block SubdIVISIOn' CLALLAM COlThTTY PARCEL NUlYffiER: wa...'...." ~- I (ptlfl/ TYPE OF WORK: SIZENALUATION: ,5- Resldenb.al 0 New Constr. 0 Re-roof 0 Stove I4/S~ SF. @ $ /SF = $ 0'/1 000, ()O o MUltl- fann.1y 0 Addmon 0 Move ~ Garage !? '1(( SF, @ $ .;{ I. 1,''6' /SF = $ / :J I 3 / ~. 0 () o CommercIal 0 Remodel 0 DemolITIon 0 Deck SF @ $ /SF = $ ~ ? 1'1. oc? o Reparr 0 SIgn 0 Other TOTAL VALUATION $ I BRIEF DESCRIPTION OF THE PROJECT: )""A"Z//.A/~ ---rn~o(L-~ ~ ~ a/&_..&//<'-r- ' COMMERCL4.LIRESIDENTIAL: Occupancy Group' No of Stones _ LotSlZe: ~ ()oO EXlstrngSq Ft'''W.e:f. Total lot coverage :J. ~ % Occupant Load ConstrucTIon Type' '[ Proposed Sq Ft). t) 3 :J... = TOTAL Sq Ft :<, I:) 3::Z- ESAIW etland( s). 0 Yes 0 No SEP A ChecklIst required? 0 Yes 0 No OtlIel. APPRO V ALS: PLAN: BLDG: DPWU: FIRE: OTHER: PLANNING USE ONLY: VALUATION OF CONSTRUCTION In all cases, a valuation amount must be entered by the applIcant. ThIs figure 'will be reVIewed and may be reVIsed by the Buildrng D1VISlOn to comply WIth current fee schedules Contact the Permit Coordrnator at 417 -4815 f01 aSSIstance. PLAN CHECK FEE: IF a plan check fee IS due 1t must be subIDltted at the tlme the bUlldrng peIIDlt applIcation and construCTIon plans are subIDltted. All other peIIDlt fees are due at tlIe TIme of pernnt 1ssuance EXPIRATION OF PLAN REVIEW: lino pernnt IS Issued w1thm180 days of the date ofapphcation, the application will expire. The BUlldrng OffiCIal can extend the tlille for actlOn by the applIcal1t up to 180 days upon wrItten request by the apphcant (see Section R1 05.3.2 of the Internatlonal BUlldmg/ResldentIal Code, 2003). No applIcaTIon can be extended more than once. I hereby certify that J have read and examined thiS applicatIOn and know the same to be true and correct I am authonzed to apply for thiS permJt and understand that It is my responsibility to determme what permits are required ,not the City'S, and that I must obtam such permits pnor to work T \Pohcles\BL-1l02_13 wpd APPlIcan~~c;2ff ~~ Date: / - 023 - 0 ~ / " " / 1724 "~I ,,/ '<, )',-, ,^~ / / ',/ 'if ". '" '''<,'' ")/6/1 I ~<: ,,'-.1 "~ ''6......, / " ',,,..... " " ,,,/ I ~ X 1619 / ~"/V " 'J "'''- / '" 'y"'" / .r ", If "'j I { I " , ~ 80 I N Area Map ThiS map IS 110t Intended to be used as a legal descriptIOn This map/dl awmg is p,oduced bv the elfV of Port Angeles {OJ lls OWIlllse and pw poses Anv other use of thIs map/drawmg shall not be the respomlblluv of the em ,/~~ (~ '~ Valalll Datum = NA VD 88 HOflz01rtal Datum = NAD 8319/ Feet " ~'d rrt:..--d G", Y'c..e..a-vI-' riff:, 0-5T /....t:> T Gl. 'is" .E.. a..S e /'7 /.- p"','r If I.:~() f"' vi qo/ 5 l -'~- I I ~ Q~"'- " '-'- I i~' <' ,~ - - 'L ~ - '~J- /YVI Cl.. 1'1 U fo-.c.. t~ V'e..cl H 0.... e. I I r\)~~ f -'--- -- ~ I I 3 ~ B DR fe-C.roV'[ 11 ' 1'\ I:)r ~l"o'lN" 0 r Oo~ov- f~V'(.. VO /)f'I6e.1r"" C' '- 'VI / ~ ~ont'. " ;" C '-,. ~ \ '\ / ).,'1' , ~ {) \ "- I G ",-",o..j-€. " 5,'del.JlLll<. \ I ~ ()( \ (/ .\ II ~/ "i \:~ ~ V)/ -~ J ~\ \ I _ {v I .25 i )0'"\ \ / -.r-v \ 1"Wl Hf Po ,....we V" / to (J" ~e"?lo..c..e <:u.......b t. GI.A T-rer D-51 CITY OF PORT ANGELES - Construction Plans The Issuance Of this permit based upon these plans, speclfi. cations and other data shall not prevent the bUlldmg official from thereafter reqUiring the correctIOn of errors in said plans, speclflcaltons and other data, or from preventmg bUlldmg operations belllg carned on thereunder when In ViolatIOn of all codes and ordmances of this Jurisdiction. iW:TI9~J3:6(ej~Sel:le.) ~'b ~ Approval Date .1 'C By ~l ( F~lE za;;J ~~. ~S- e~~.LO 90 ~l uer -- -I o -I jl:! '"0 . IS) w Optional Glamour Bath J .-;wola.y' /1/ ~ ;3 ~ qp"/vt:zrre M!TER BED OOM t~ . t2'~ - 1/\, I ' ,n I oorW\o Y'" I '+ ~~dfl V'" I \ I I I \ l I I I I I l (;.0-- .,-~ ~,II; <aHlrmtnIPEJtl1~Redm.." .011 ..".... It. ~U.._A D......__ .V ~/ -$ ( / i ~ .T"-V~ crt-' , '- I,}- t c. t..,e re.; (' LIVING ROOM 11'~'" "-6" 3 \ ~ I L t....o.,r 1-"oJl ~ ll!.e-',~" .,l/ tv Do_.,.. V-ODEl143 3 BEDROOM. 2 BATH ACTUAL SIZE: 2S'-8"x4B'oO" TOTAL AREA: 1.280 SQ. FT. ~ MJ.W, . I 26~-8" il IS: r.. "- IS r.. !!2IIS! 17.14~ I!IIt& Munufuctured House F oundu tlon Plun Pod Angeles, VIA I I I ~-------------------56~--------------------1 I I TYP I I 4 corner~ I #4 Rebo.r continuous I _____~'~~j_ 1--- All sides I ! 1'-6' G"';---"'U-----n- ---"'(J----"';: n1 T -1- Il.ol--------.::.L.--------~---Fl I I II II I II 5,5' Concrete slub II I II 2500 psi II I I I MClrrlClge line I I 2(' II See Mo.nuFo.durer Colul'ln support requlrel'lents II I II II I II II I II II J ~---~---------~--~--~ ~---~----~----~--~--~ - -------- NOTEI All set up deto.lls to be per Mo.nuf'o.cturer Set Up Mo.nuo.l 6 Anchors Equo.lly Spo.ced ANCHOR DETAIL #4 rebo.r ~, Tie Down Engineering Mdl MIJ2 Go.l vo.nlzed PN 59121 or equlvo.lent Mbedded 5' Typlco.l of 12 . ~ ( 6 Anchors Equo.lly Spo.ced 2'X2' po.d Concrete Notesl ASTM Std C-150 & C-33 Re-bo.r ASTM A-615 Gro.de 40 Vnlley Properties & Construction) Inc ~ Frame Spacing (in) S tra p Max. Beam Tie Spacing ft o.c. 80 96 99.5 Angle M a x. S id e w a" H t. (in) Max. t'ler M a x. t' Ie r M a x. t' Ie r Max. H t. (in) H t. (in) H t. (in) o eg rees 84 90 96 14 NA NA 40 13-5 12-7 11-11 CD 19 NA NA 45 12-4 11 -7 11 -0 "C E 25 15 13 50 11-3 10-6 10-0 ~ m CD CD 32 21 18 55 10-0 9-5 8 -11 :c lD ::> iii 42 28 25 60 8-9 8-3 7-9 0 Cl CD 54 37 34 65 7-4 6-11 6-6 z v 6-0 5-7 5-4 N 73 51 46 70 80 74 67 75 4-6 4-3 4-0 . .-'- -.. ~ . - -- 19 13 NA 40 13-5 12-7 11-11 Ql 26 18 16 45 12-4 1 1 -7 11 -0 "C 22 50 11 -3 1 0-6 1 0-0 ~ E 33 24 m CD CD 42 31 28 55 10-0 9-5 8 -11 :c lD ::> ... 54 40 37 60 8-9 8-3 7-9 8 m Ql 69 52 49 65 7-4 6 -11 6-6 z co 66 6-0 5-7 5-4 N 80 70 70 NA 80 80 75 4-6 4-3 4-0 24 l17) 16 40 13-5 12-7 (11-11') CD 31 '2"! 21 45 12-4 11-7 11-=lJ "C E 10-0 ~ 39 30 28 50 11-3 10-6 m Ql Ql 49 38 35 55 10-0 9-5 8 -11 :c lD ::> ... 62 49 46 60 8-9 8-3 7-9 0 III Cl CD 80 63 59 65 7-4 6 -11 6-6 CD z N NA 80 79 70 6-0 5-7 5-4 NA NA 80 75 4-6 4-3 4-0 Ql 32 26 24 40 13-5 12-7 11-11 "C E ~ 41 33 31 45 12-4 11 -7 11 -0 III CD Ql 51 42 40 50 11 -3 10-6 10-0 :c lD ::> ... 64 52 50 55 10-0 9-5 8 -11 0 III Cl CD 80 66 63 60 8-9 8-3 7-9 z N (') NA 80 80 65 7-4 6 -11 6-6 . - '" E 43 36 34 40 13-5 12-7 11-11 'tJ ~ m 53 45 43 45 12-4 11 -7 11 -0 '" Ql :a lD 65 56 54 50 11-3 10-6 10-0 :J ... 0 III 80 69 67 55 10-0 9-5 8 -11 c CD co z NA 80 80 l') 60 8-9 8-3 7-9 Wind Zone 1- Multi-Section Homes 5.4.1.2 Installation of Ground Anchors _ Ground anchors must be installed in full conformance with the anchor manufacturer's instructions. Ground anchors for all Wind Zones must have a stabilizer plate at the top of the anchor unless the manufacturer's instructions do not require stabilizer plates for a particular installation of their model. In the latter case, conform to the manufacturer's instructions provided that the required holding capacity is produced. Ground anchors for Wind Zone I may have a single head. Ground anchors for Wind Zone" and III must have double heads. Install ground anchors vertically with stabilizers as shown in Figure 5.12. All ground anchors shall be embedded below the frost line and be at least 12 inches above the water table. Page 32 2llOO.CM Professional EngIneers Seal TABLE 4.2A MINIMUM PIER LOADS FRAME PLUS PERIMETER BLOCKING Both Frame and Perimeter Blocking Required Minimum Pier Capacity - Lbs. ROOF SECTION LIVE WIDTH LOAD Maximum Pier Spacing - Feet PSF 4 !:; 6 7 A 10 1? 14 12 20 FRAME 1,300 1,600 2,000 2,300 2,600 3,300 3,900 4,600 PERIMETER 1000 1200 1500 1700 2000 N/A N/A N/A 30 FRAM E 1,300 1,600 2,000 2,300 2,600 3,300 3,900 4,600 PERIMETER 1300 1600 1900 2200 2600 N/A N/A N/A 40 FRAME 1,300 1,600 2,000 2,300 2,600 3,300 3,900 4,600 PERIMETER 1600 2000 2400 2700 3100 N/A N/A N/A 60 FRAME 1,300 1,600 2,000 2,300 2,g~0 3,300 3,900 4,600 PERIMETER 2:10n ?'700 3200 3800 4 00 N/A N/A N/A 80 FRAME 1,300 ~,~gg ~,~gg ~,~gg ~,~gg 3,300 3N~~0 4,600 PERIMETER ?'7nn N/A N/A 13 20 FRAME 1,400 1,800 2,100 2,500 2,900 3,600 4,300 5,000 PERIMETER 1:100 1300 1600 1900 2100 N/A N/A N/A 30 FRAME 1,400 1,800 2,100 2,500 2,900 3,600 4,300 5,000 PERIMETER 1.400 1700 2100 2400 2800 N/A N/A N/A 40 FRAM E 1,400 1,800 2,100 2,500 2,900 3,600 4,300 5,000 PERIMETER 1700 ?'100 2:500 3000 3400 N/A N/A N/A 60 FRAME ~ ,400 ~,800 2,100 2,500 2,900 3,600 4N300 5,000 PERIMETER .300 900 3:500 4100 4600 N/A IA N/A 80 FRAME 1,400 ~,~gg 2'lgg 2,500 ~,~gg 3N~~0 4N~~0 5N~~0 -""' PERIMETER ~'nnn A'A, S:?OO ~ 20 FRAM E 1,500 1,900 2,300 2,700 3,000 3,800 4,600 N/A PERIMETER 1 100 1400 1700 2000 2300 N/A N/A N/A 30 FRAM E 1,500 1,900 2,300 2,700 3,000 3,800 4,600 N/A PERIMETER 1500 1800 2:200 2600 2900 N/A N/A N/A 40 FRAME 1,500 ~,900 2,300 2,700 3,000 3N800 4,600 N/A PERIMETER 1 800 200 2700 3100 3600 IA N/A N/A 60 FRAM E 1,500 1,900 2,300 2,700 3,000 3,800 4,600 N/A PERIMETER 2:400 3100 3700 <!(300 4900 N/A N/A N/A 80 FRAME k~gg k~gg ~,~gg ~,~gg ~,ggg 3N~~0 4,600 N/A PERIMETER N/A N/A 16 20 FRAME 1,700 2,100 2,6~g 3,000 3,400 4,300 5,~~0 N/A PERIMETER 1200 1500 180 2:100 ?400 N/A NI N/A 30 FRAME 1,700 2,100 2,600 3,000 3,400 4,300 5,~~0 N/A PERIMETER 1"600 1.900 2300 2700 3100 N/A NI N/A 40 FRAM E 1,700 2,100 2,600 ~,ggg ~,~gg 4,300 5,100 ~~~ PERIMETER 1'~nn ?'.4nn ?'~nn N/A N1A 18 20 FRAME 1,900 2,~~0 2,900 3,400 3,900 4,800 5.800 N~~ PERIMETER 1300 1 00 ?'OOO 2400 2:700 N/A N/A NI 30 FRAME 1,900 2,400 2,900 3,400 3,~gp 4,800 5~~0 ~~A PERIMETER 1700 2:?00 2:600 3000 3 0 N/A IA 40 FRAME 1,900 2,400 2,900 3,400 ~,~gg 4,800 5N~~0 N/A PERIMETER ~,. 1 on ?'7nn ~'?On ~'70n N/A N/A 1. Mate line pier blocking capacity is 2 x perimeter pier capacity and shall not exceed 4 ft. spacing. 2. Blocking shall be located each side of openings in perimeter and marriage walls over 4 ft. (see tables 4.1 B or 4.2B). 3. Perimeter support recommended for gypsum board tape and texture homes. Page 13 2000,04 ProfessoonaJ Engmeers Seal FIGURE 4.3 TYPICAL PIER LOCATIONS ~ TYPICAL TIE DOWN STRAP FRAME BLOCKS III FRAME SUPPORT o PERIMETER SUPPORT (IF USED) ~ MATE LINE OPENING SUPPORT o SIDEWALL OPENING PERIMETER BLOCKS MATE-WALL OPENING PERIMETER BLOCK WHEN SECTIONS ARE OFFSET AS SHOWN MATE LINE BLOCKS FRAME BLOCKS PERIMETER BLOCKS FOR OPENING IN SIDEWALL REFER TO 4.1.5.1 MULTI-SECTION NOTES FOR OFF-SET DESIGN 1. ROOF OF OFF-SET SECTION MUST HAVE CENTER PEAK. 2. MAX. OFFSET WITHOUT CENTER PEAK IS 4' IN WIND ZONE I ONLY. 3. ALL OTHER OFF SETS NEED SET-UP ADDENDUM. 4. OFF-SET SHOULD BE TIED DOWN AND BLOCKED AS A SINGLE SECTION FOR THAT PORTION OF THE HOME. ALSO BLOCKING SHALL BE PLACED AT THE INSIDE CORNERS WHERE FLOORS JOIN. FRAME OR FRAME PLUS PERIMETER BLOCKING SEE SUPPORT TABLE ~ TYPICAL TIE DOWN STRAP FRAME BLOCKS PERIMETER BLOCKS PERIMETER BLOCKS FOR OPENING IN SIDEWALL REFER TO 4.1.5.1 SINGLE- SECTION FRAME OR FRAME PLUS PERIMETER BLOCKING SEE SUPPORT TABLE Page 17 2000.04 ProfessIOnal Englll9lll'S Seal Fred Ga.""t:,.~tL~ G R fl.Ai:J e. a:t1:oAb e cI. 1'7 lIP 0 - 5'7 F..G J {-oJ- (, '-1'Q. i5 'Ib ~ !- I : I ~ ---I-.~ --r--, ."~-r~- ~- (..-:. r - - .._--J ... __ __ __1-._ ._.1- - ~.:_L_. ;~~_~.-..!_:~-~-~~_.-~~-.I-~;;~~ -: C J ~'~H:OTc':-,-c~ L .---. ---.----....1--.-- -.1----1 ----t--- ---r-- .--,-- --r----- - --r':"- - - I' I L I , -_L__.' -r'_~'._--rn ____u_____ Tl I: I' 3D...t b & . j- I ' . I , 1 I i . ; I ~ I I : I I 11: , I i I ; ! I ' . I . i I ! _-+_L-LJ_ 1..&../" f)(30 / R~ STtl e. Elcvpf~f..} 1)oofl +~oW "~CIU UAIt..'1 petL (!)pt:~L~ .s..x-t::.c. -j L--. ~__ .-...--- ~(" - . i " I' I , I I f T . I n "\ I . . , . .- . i I I . , , . I I I- I .. I f . I . ............ . ..... , -, . I I L I ~ j),o'/3 ~ \J\ .~ I;:) I ":t .. - : , .. Lerr S/de.. ~'YI ~ .~ 51' I R'P ! --iJ f:r 8~ ec raK~1 t.j.Fr I!J ~QCC js.-' i . ; , \;;u/ f . ~ 'SI.4I!e1" flod ! I . - - :B'P ~I .:l v'" -Cf'.oe.. .... ( '1 \~ t>~c~:J' I . . JJ;Ol<.ou,~ ~.. ~o , ~II ,- r . i . I i" - -_.' - - . J, - j.... l ' f' -- -- '- --- . -- -- -.-- -. -- -- - . . . . I I i /117R D-<7T I I ----------- ....-- --- 1 f i ~ j i ~ - ....-. -- 0 .-- ---- . -- - - -- -------. --.-.- - : . I.i 'i ~ kJ '\kJ" C() W~ . I./j..?, 1 ;1~ . :J..,.." 11<~:<,", Fiona P'AIU. rJ-'f-.lrt H~ . j ~ --'~ :....&of:. ,Oerrt,c...l.1e.J - - - - . - ----. . . -i ! }f i -j . f - ! I , J6( , - \ ; ,- - ~ - , 0 t , I . I - , .' ! -IQ.u.~~ .;l.," ole -- -. i , " I - . . , I J .i r .1 .i ; . . .f , '! ;AY8 <<.0 ,0 U. f . I . i . . Q; ,j ~i : i ! /. I.L 1f I'UL II., H 4\..1 .y, i sP : ~ f-- Ij/ - .' - .:?\le.II....~ _~.L i ! i - Wl c\.-~ -- ! P ',If II R.~ 8P 3 Tllb c.p ioo7 ,5' flt' 7,g. 0-' 3: r:t <Sc.. Lf: 12 P.rtd ~ I II 11 -, 'j 'i'1t!.;(K. j 6 H~Jr.c.. Fr-tJ....' V l'e~ I. '\ { -'; 4- ~ .. J ~..'- C'~r ;;z ~ .LI ~_ ?'J Fred -- G- t:;t r-C eo-. ~ /'7/4> D-r;j'T Fb hI a'11.c.J-t' ;. w /I q '6 -.:, t:. ;2.., /1rra.c.."'-e..d G~ y.~~~ 3 Tab Roofing, 15 lb Felt EnQ. Manufactured Trusses @ 24" X 6" Fascia Vent Blocld ng 2.5 or Equivalent Clips #0 H-e.c\:r 'i,' 2 x 4. Studs @ 16" o.c. .- . .' :3 ~ 3 Ga.JV, 2 x 4 Pressure Treated Si 11 S~tulJ.e.. k14.~4e.r 1/2" x 10" Anchor Bolt 61 o.c. ( 6" Concrete Stem Wall No. 4 Bar - Vertica 48'OC. . I.f" Sf eJ:, ,./ '. // // ~ ------ . ./ //~~~~ / ~ /- .. _.~ /.,1 ~ 5"'/.l-b '5T~e.1 L Concrete Footing wI 2 No.4 Bars Continue . Ia.;c 4SEASONS ENGINEERING, INC (360) 452-3023 · Fax (360) 452-3047 619 S. Chase Street. Port Angeles, WA 98362 April 25, 2006 Jim Lieriy City of Port Angeles Building Official PO Box 1150 Port Angeles, W A 98362 FilE Subject: Bolt hole inspection, Fred Garceau, 1716 "0" St., Port Angeles, W A 98363 4 Seasons Engineering, Inc. has provided an inspection of the drilled holes for epoxy in place anchor bolts and hold down bolts at the above address. All holes inspected on April 24, 2006 were in compliance. If there are any questions, please give me a call at (360) 452-3023. Sincerely, Donna J. Petersen P.E. D cc. Fred Garceau ! EXPIRE~ .A . D'1 _.-.J RECEIVED [ APR 262006 ] CITY OF PORT ANGELES BUILDING DIVISION RECEfVED AP~ .2 2006 , .. I 1'\ Y. """ ~- '--1l (:;- A h: (!t' ~K.-' - I J :IR'P - a.'~C 11 'P' . , ~ ..:;:p 'hQCi' n.'~ '1' ono. Ic...lnt"' . ,: \i1)/ e're J A,.,.. .oil. ~Jr.- 1 : ~4.ee1' 1lo t\... :J.VY 'V 'oe.. ... U 1 \('t- o~"r ,;'1 'o~ !BP .' ~' IJ>>......... ,~ -1/ .. I 5 . __" ~o ~ II.:> os I . 4" n(HL~ I ( () i I . i~ . I - r - --.' i- -. - '- .. - --~- . - --- ~- -- ~_. . - I -- - -- - I . I -------------...-..---- I , I 17/~ o.S; ! . . . . 1J'i~ -.... ! J ~.\",.J...,. a ' -- .- ___..___.. ._.u 4_ .. _. --- ! . '- "'" I-k.Ad:<..... !Jj..?J w~ ! . .' . cl Pi..... .. f}...~ H~ ;~A.j ! :...~ ,De..""""~l1~ci . "'! i - -.. .. .. .. .. -----.. ---, l . , ~f ! - 1 ; .II>~ ! 1- - - j I - - ,i --' - - . I i 1 I . TQ.\u~~ . . I .. .;l.," ole:. , ." . ! -- .. : 1 I I ; :- ,1 .- . 1 t . I I . I , .i I I . . . ! ~l :J..)l'"f c..uAU - ! ! ... ., ! J-- ",,"' IL ... ..d. ~. , i -- - ! sP i I ~\lecr~ 4-ASP .. _!il- ! 1.. " ~~~Wl~~ <J 4 37,41, <:>>-p ioo-f ,s' ~lr "7"". 0", ASP A 1Z--u .. _ trlQuc..tNru fled TIZ.,,*s .:J..qo:ot:... 3 : l=l 6 c.. 4: 1:1. R:;::rd .If'X~ij 6 _H~Jr'.c.. Fr()~l V,'e~ I. '\ { ; . ~! "It .. \~OL\..,) DOVJ~ ~ V I If d, - ~ II ~ ~~t)-:" I H D 2 C?/e, 'P A, \, ~~ e.- \''1\.. 'b 'l V\ \0 C.ON c.xe..\.e..) 'S~\ oCl. :L' E'?O)<.T ~ · f ----: . ,u.,.~. ~ '\oOr...i' CITY OF PORT ANGELES PUBLIC WORKS - ELECTRICAL DIVISION :Ul EAST 5TH STREET. PORT ANGELES. WA 91;:162 Application Number Application pin number' Property Address ASSESSOR PARCEL NUMBER: Tenant nbr, name Application type description Subdivision Name Property Use Property Zoning . . . Application valuation 06-00000073 Date 937747 1716 0 ST 06-30-00-4-4-0280-0000- FRED GARCEAU RES MANUFACTURED HOME 3/22/06 RS9 RESDNTL SINGLE FAMILY 66314 Owner Contractor EAGLE'S LAIR LMTD PARTNERSHIP PO BOX 798 SNOQUALMIE WA 980650798 OWNER Other struct info . TOTAL % LOT COVERAGE EXISTING LOT COVERAGE LOT SIZE PROPOSED LOT COVERAGE TOTAL LOT COVERAGE 23.00 1. 00 9000.00 2032.00 2032.00 Permit . . . . . Additional desc . Permit pin number Sub Contractor Permit Fee Issue Date Expiration Date ELECTRICAL NEW RESIDENTIAL RW BECKER/ MOBILE 72967 RW BECKER ELECTRIC 78.70 3/22/06 9/18/06 Plan Check Fee Valuation .00 o "- --.J " ~ Qty 1. 00 Unit Charge Per 78.7000 ECH EL-MANF HOME SERVICE & FEEDER Extension 78.70 () Special Notes and Comments Address numbers shall be plainly visible from the street. Address numbers shall be a minimum of six inches high and be of contrasting color from the background. All homes in new subdivisions that are outside of the Fire Department four-minute response area shall be equipped with residential fire sprinkler systems that comply with the International Fire Code (IFC) and National Fire Protection Association (NFPA). 01/30/2006 01:48 PM SROBERDS --The proposal will result in the placement of a new mfg home in the RS-9 for total lot coverage of 23%. No land use issues are noted. Electrical load calculations and elctrical permits are required. Electrical connection fee of $410.00. U/g service form pole at s/e corner of lot. 01/24/2006 04:21 PM GMCLAIN ---------------------------- Sidewalk to City standards along "0" Street required for school walking route. Sanitary sewer connection inspection is required by Public Works prior to back fill of ditch. 24 hour advance notice is required. Construct driveway and Sidewalks to City Standards. No concrete with exposed aggregate allowed in the City road right of way. An inspection by Public Works fA '\ , COMMENTS! ACTION NEEDED ELECTRICAL PERMIT INSPECTION RECORD ." CALL 417-4735 FOR ELECTRICAL INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLA WFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE IT IS INSPECTED AND ACCEPTED. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED COMMENTS , YES NO I JII :H ~ Will 11TH-IN / CUVhK ShKVICh FINAL I , GENERAL COMMENTS: PW-II02.U (4196) '~ w CITY OF PORT ANGELES PUBLIC WORKS - ELECTRICAL DIVISION ~21 EAST 5TH STREET. PORT ANGELES. WA 98362 Application Number . . . . . 06-00000073 Application pin number 937747 Page Date 2 3/22/06 Special Notes and Comments Engineering is required prior to prouring concrete. Other Fees SEWER SYSTEM DELV CHARGE STATE SURCHARGE PW WATER SYSTEM USE FEE 870.00 4.50 1200.00 Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 78.70 78.70 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 2074.50 2074.50 .00 .00 Grand Total 2153.20 2153.20 .00 .00 COMMENTS! ACTION NEEDED ELECTRICAL PERMIT INSPECTION RECORD CALL 417-4735 FOR ELECTRICAL INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLA WFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE IT IS INSPECTED AND ACCEPTED. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED COMMENTS YES NO I JlI :H WIIII'yH-IN / COVER ~bK V lCb "TN AT I;, ~,.1~~ I7h I .k.i ) , I GENERAL COMMENTS: PW-II02.U (4196) '''.,~. J(id~ ~ '\oOr~ CITY OF PORT ANGELES PUBLIC WORKS - ELECTRICAL DIVISION ~21 EAST 5TH STREET. PORT ANGELES. WA 98362 r\ '" Application Number Application pin number Property Address ASSESSOR PARCEL NUMBER: Tenant nbr, name Application type description Subdivision Name Property Use Property zoning . . . Application valuation 06-00000073 Date 937747 1716 0 ST 06-30-00-4-4-0280-0000- FRED GARCEAU RES MANUFACTURED HOME RS9 RESDNTL SINGLE FAMILY 66314 Owner Contractor EAGLE'S LAIR LMTD PARTNERSHIP PO BOX 798 SNOQUALMIE WA 980650798 OWNER Other struct info . TOTAL % LOT COVERAGE EXISTING LOT COVERAGE LOT SIZE PROPOSED LOT COVERAGE TOTAL LOT COVERAGE Permit . . . . . Additional desc . Permit pin number Sub Contractor Permit Fee Issue Date Expiration Date ELECTRICAL NEW RESIDENTIAL RW BECKER/ GARAGE 74468 RW BECKER ELECTRIC 48.10 4/13/06 10/10/06 Plan Check Fee Valuation Qty 1. 00 Unit Charge Per 48.1000 ECH EL-R-OUTBD/DTCH GAR SEP Special Notes and Comments Address numbers shall be plainly visible from the street. Address numbers shall be a minimum of six inches high and be of contrasting color from the background. All homes in new subdivisions that are outside of the Fire Department four-minute response area shall be equipped with residential fire sprinkler systems that comply with the International Fire Code (IFC) and National Fire Protection Association (NFPA). 01/30/2006 01:48 PM SROBERDS --The proposal will result in the placement of a new mfg home in the RS-9 for total lot coverage of 23%. No land use issues are noted. Electrical load calculations and elctrical permits are required. Electrical cohn€ction fee of $410.00. U/g service form pole at s/e corner of lot. 01/24/2006 04:21 PM GMCLAIN ---------------------------- Sidewalk to City standards along "0" Street required for school walking route. Sanitary sewer connection inspection is required by Public Works PFior to back fill of ditch. 24 hour advance notice is required. Construct driveway and Sidewalks to City Standards. No concrete with exposed aggregate allowed in the City road right of way. An inspection by Public Works COMMENTS/ACTION NEEDED 4/17/06 23.00 1. 00 9000.00 2032.00 2032.00 .00 o ......... "-.l ........ (S' Extension 48.10 () {j\ :; ELECTRICAL PERMIT INSPECTION RECORD { \LL 417-4735 FOR ELECTRICAL INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLA WFUL TO COVER, INSULA TE OR CONCEAL ANY WORK BEFORE IT IS INSPECTED AND ACCEPTED. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED COMMENTS I YES NO III .. 'H Will I( iH-IN I CUV,hK SERVICh "IN A T I I GENERAL COMMENTS: PW-II02.U (4196) tI '\oO~ CITY OF PORT ANGELES PUBLIC WORKS - ELECTRICAL DIVISION ~21 EAST 5TH STREET. PORT ANGELES. WA 98362 Application Number . . . . . 06-00000073 Application pin number -. . . 937747 Page Date 2 4/17/06 Special Notes and Comments Engineering is required prior to prouring concrete. Other Fees RES OVERHEAD SERVICE FEE SEWER SYSTEM DELV CHARGE STATE SURCHARGE PW WATER SYSTEM USE FEE 410.00 870.00 4.50 1200.00 Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 48.10 48.10 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 2484.50 2484.50 .00 .00 Grand Total 2532.60 2532.60 .00 .00 COMMENTS/ACTION NEEDED ELECfRICAL PERMIT INSPECTION RECORD G ~..LL 417-4735 FOR ELECTRICAL INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLA WFUL TO COVER, INSULA TE OR CONCEAL ANY WORK BEFORE IT IS INSPECTED AND ACCEPTED. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE I ACCEPTED COMMENTS I YES I NO III '.'hI WlllllyH_IN / COVER ShK VICh FINAL I c/"'';;'O -06 rh~.J GENERAL COMMENTS: PW-II02.U (4196)