Loading...
HomeMy WebLinkAbout118 Vashon Ave - Building CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY DEVELOPMENT - BUILDING DIVISION 321 EAST5TH STREET, PORT ANGELES, WA 98362 · ..~.-.~.~,~..~,~ ~ ~w~.~ ISSUED: 11/18/2002 I"[:l~mll NO: 13~48 OWNER/APPLICANT PROPERTY LOCATION KARL FELDERN 118 VASHON 16212 BOTH ELL EVERETT Lot: MILL CREEK, WA 98012 Block: [] Long Legal 206/818-6112 Subdivision: PSCC 2ND ADDITION T: S: Parcel No: CONTRACTOR ARCHITECT ROADRUNNNER SERVICE N/A 11410 CALLOW RD. LAKE STEVENS, WA 98258-0000 , 98360-0000 425/334-5535 360/000-0000 PROJECT INFO Project Value: $122,500.00 SFD Units: 1 Commercial: 0 Project Type: MANUF. HOME SFD SQ FT: 1,232 Industrial: 0 Occupancy Type: RESIDENTIAL Garage: 0 Occupancy Group: MFD Units: 0 Construction Type: MFD SQ FT: 0 Zoning Use: PROJECT NOTES ~O {'~ [ ~.1, ~ [.._~ 1232 SQ. FT. DOUBLE WiDE MANUFACTURED HOME RECEIPT#9934 C FEES ASSESSMENT ~.. Building Permit: $0.00 Misc Fee 1: $0.00 Plan Check: $0.00 Misc Fee 2: $0.00 State Surcharge: $4.50 Misc Fee 3; $0.00 House Moving: $0.00 Manufactured Home: $230.00 Sign: $0.00 TOTAL FEE: $234.50 Plumbing: $0.00 AMOUNT PAID: $234.50 Mechanical: $0.00 BALANCE DUE: $0.00 Radon: $0.00 Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if wor~ or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work as commenced, or if required Inspections have not been requested within 180 days from the last inspection. I hereby certify that i have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Signature of Contractor or Authorized Agent Date Sign~ of Owner.~ 0wner is builder) ?:\PLANNING~FORMS~ 1102.15 [4/2002]  D~ t~.:~ BUILDING PERMIT- APPLICATION I The Building Permit Applica~'on must be filled out completely. Please type or print in Ink. If you have any questions, please call 41%4815 Applicant or Agent: ]~I/F ,2 LLC.- Phone: ~?o-'gl</-?~11~ Architect/Engineer ....... ~ ~ --=. Contractor ~o.~rJr-tjnn?~'- ~'~r-t/~O~_Liccnse #: Exp:. . LEGAL DESCRIPTION: Lot: Block: Sub~/vision CLALLAM COUNTY PARCEL NUMBER:. Credit Card Holder Name: Billing Address: City:. Credit Card #: Exp. Date: ., VISA MC ~ReE OF WORK: SIZE/VALUATION: sidential rn New Cons~r. n Re-roof [] Wood-stove SF ~ $. /SF. 13 MultiJamily [] AddiSon rn Move /3 Garage SF.(~$..~/SF.=$ n Commercial [] Remodel [] D~molition 5 Deck ~ SF, ~ $. ~ Repair ~ Sign [] TOTAL VALUATION $ ! E ~ _~-~O- COI~flVIERCL&I. dRESIDENTIAL: Occupancy C.~oup:. : O¢¢npant Load: Comt~clion Type: Exi,Ong Lot Coverage: Cov~age: ~/~[. fl. = TOTAL LOT COVERAGE: /sq. fl. /~q. 1~. .PLANNING !/SE ONLY: APPROVALS: .~ - I~AN No~tesi.. ~ ~ BLDG. ESA/W~tland(s): tn Yes r~ No SEPA Ch~kli~ r~quited? r~ Yea r~ No Other: O'l'lt/~R. BUILDINg PERMIT APPLICATION SUlil~li-I'AL: Your application and site plan must b~.fllIed attt completely to be accepted for review. The Builedag Division m provi& yon with more detailed information on the application and plan submittal req~irmmmm. Your completed application, site plan (for addition~) and building comtmction plans ar~ to be submitted to th~ Building Division. VALUATION OF CONSTRUCTION: In all eas~, a valuation amount mu~t be entered by tl~ applicant. Thi~ figure will be reviewed and may be revised by th~ Building Division to comply with current f~¢ schedules. Contact lh~ Pmmit Coordinator at 417-4815 for assistance. PLAN CBlgCK FEE: Your plan check fee ia du~ at the lime the building p~rmit application and comlruction plan~ axe submflted. All other permit fees are due at th~ tim_~ of pm'mit issuance. EXPIRATION OF PLAN RgVI~W: If no permit is issued within 180 days of the date of applicatioo, thio application will expire. The Building Offidal can ~xt~nd ~e ~ for amion by *t~ applicanl up to 180 days upon wri~n r~tn~st by the applicant (~ee $~etion 107.4 of the Uniform Building Code, cun~nt edition). No application can b~ ~xtended mor~ than once. I hereby certify that [ have read and examined this application and know the same to be true and correct, and £ am authorized to apply for thi~ permit. I understand it is not the City's legal responsibility to determine what perrnit~ are required; it remains the applicant's responsibility to determine what permits are required and to obtain such. . 11/05/02 TUE 00:42 FAX 397 9866 Roadrunner Service 0003 .~-2000 FRI 0~:27 ?1~ F~g NO, P. 02 SNOHOMtSH COUNTY PLANNING & DEVELOPMENT SERVICES ~ F.I t'~ I~ . ~',~A,,UFA.,.,TUEE.~, HOME CONCRE;TE SLAB OR RIBBON CONSTRUCTION ~,~_, AIL OPTION T;~DQWN ' ,, ~OOP .~MO~PN~,[~j~,OC ~u ' i MrJxi~Jm ~" Sleeve m~y b~ ~ed [O ~ak~ the connection of the manufaclured onchor 11/05/02 TUE 00:43 FAX 397 9866 Roadrunner Servlce ~005 #ZN~ CJ)NCRUE FOOTII~ $IZ£$ ~]ZL ~&~[NG ~lP/l~lTY ISO~ PSl ~ PSl ~o0' P~I 3mO PSI NZ/dlleUN ~ LGAD CP~') ROi}' LOA~ a~c) R~F LOA~ ~) ~ LO~ ~) 'A' ~ 6 ~ 8 10 6 6 ,8 l0 6 6 G 6 6 G 6 8 '~ 6...." 6x 10 10 ~ 6 8 8 6 ~ 6 8 ~ ~ 6 6 ~ILE ~T A STR~ K~[~NT TO ~[T ~ ~ET~ ~S ~N~S ~R~TER V~L SU~T ~ ~S V]~ ~ ~ TO PRE~NT ~S~TIC C~ ~[TT[ ~S ~LL ~[ ~ aNY V~TY CLA[NS ~TAINI~ TO OR.ALL :~ I~ P~ ~,~T iS ~T ~NT ON ~& F~ ~ ~ , ~L VALL ~LfE~TE RE~S S[~V~L ~ ~ ~ TYPICAL ~UBLE ~[~E ~]TH P~T[AL SLA~ FOUNDATION 11/05/02 TIlE 00:42 FAX 397 9866 Roe~drun~er Service ~004 TIE-DOWN INSTRUCTIONS Il" oiJ of the home. In Zone II and III. connect both the vertical tie-down straps and the diagonal frame straps to double After blocking and leveling, the home must be made head anchors. Straps should not be tight at this secure from overturning due to wind. The requirements will point. Construct the tie-down system with adjustable vary depending on which wind zone your home is located in devices in o~der that the strap tension may be periedi- (see the wind zone map shown on page 4.). cally adjusted to compensate for heaving and settling In Wino Zone I. tie-0own is accomplished by installing 6. With one man on each sloe of the home, start at the frame ties only supplied by the owner or installer, l'ness front and tighten straps on both sides at the same time. straps are wrapped around the frame I-beams and The home could be pulled ol/ its piers if all straps are ancho~nd, tightened on one side at a time. I~ Wind Zones II.~nd III, vertical tie-down straps insteJled. by thq. factory ston~ the sidewafls must also be connected SINGLE WIDE CHART to grou~danchors in addition to the frame ties. '\ ~e~c~on The number of frame and vertical ties required varies sw~, ~.L(~ MAXlMUMAHCHOR~..ACING{',:T,) depending on the wind zone and the strapping method ~-rH0sC~AC~ ZO~EI [ ZO~J~' 1 Ground anchors should be certified .by a professional engineer, architect or a nationally recognized testing labora- tory as to their resistance, based on the maximum angle of diagonal tie and/or vertical tie loading and angle of anchor ?-0" installation, and'type of soil in which the anchor is to be MAX. ~(. installed. Ground anchors should be embedde0 below the frost line and be at least 12" above the water table. . Ground anchors should be Installed to their full depth, and stabilizer plates should be installed to provide added resistance to overturning and sliding forces. Minimum ancl~or capacity required is as noted and indi- ~CH0~ coted on P.E. certified Ground Anchor/Frame Tie Strapping ~0P Vll~ OF Requirements detail. The. following instructions are for installing tis-aowns on a Marlette by Sohult home. DO~BL~ "- WIDE CHART 1, From the chart and details below, select either the single ~c,~4o~I~' or double strap metho(t (Note: Double strap method is s~ not available in zones II an0 Ill). Be sure to use ground ~HOP CAPAClI~ ZONE ~nNEll zePEILI anchors equal to or stronger than the minimum load ~ ,77~LaS. 11 / 11' 11' ,' ,~'-,'l , 4' l,'.4',5'-,' capacities listed in the chart for the method selected. DOUBLE =Z ,,,, ,. ., ., 2. Install ground anchom at the required locations per the NA-NOTAPPUCABt. E ~l~esj~e~tmpspa~lng). details shown below. Anchors should be installed per the manufacturer's instructions. 2'-0' DOUBLE WIDE 2'-0' In Zone I, install ~lngle head ground anchors at all ~x. INT[RII[DRT[ ~IN~ P[~ 0dArq "frame-tie-only" locations when using the single strap method. Install double head ground anchors at all '?came- tie-only" locations when using the double strap method. In Zones 11 and Ill, install double head ground a~chors at all vertical tie locations. 3, The first and last frame tres must be installed within 2'-0" u~c L~[ of the. ends of the home, · 4. Endwall t[e-downa are required at each I-beam. Run anchor straps from a double head anchor through angle~ slot cut in I-beam web, then, return to double head anchor, /~ SI~LL EN ~V~U. ~NCHOI~ 5. Connect frame ties to the frame I-beam at all ground~.~..~ TOP MEW 0¢ H0~ anchor locations (double and single head) on both sides 28