Loading...
HomeMy WebLinkAbout3115 City Lights Place - Building ".�a. t ems.^_ �;"'� �i. :4� ,. i ., ., i - - i _ .. i i - -2 SPI 1 - 2 SINGLE-FAMILY ELECTRICAL PERMIT APPLICATION �- PUblic NVorks and t=utilities Department 321 E. 5th Street, Port Angeles, WA 98362 360.417.4735 1 www.cityofpa.us ! electricalpenxnits��,cityofpa.us W `N Project Address: 3115 City Lights Place Port Angeles, WA 98362 Project Description: 7.0 kW Grid-Tied PV Roof top mounted 1�1 Single-Family Residential ❑ Duplex/ARU Building Square footage: OWNER INFORMATION Name: Deborah Frazier Email: frazierleach(a)_wavecable.com Mailing Address: 3115 City Lights Place Port Angeles, WA 98362 Phone: (360)477-7762 ELECTRICAL CONTRACTOR ORMATION Name: Power Trip Energy Corp License: POWERTE964JN Mailing Address: 83 Denny Ave Port Townsend, WA 98368 Expiration Date: April 2022 Email: buddy@powertripenergy.com Phone: (360)643-3080 . .O DETAILSJECT bm Unit Charge Quantity Total(Quantity x Unit Charge) Service/Feeder 200 Amp. $120.00 f' $ Service/Feeder 201-400 Amp. $146.00 $ Service/Feeder 401-600 Amp. $205.00 $ Service/Feeder 601-1000 Amp. $262.00 $ Service/Feeder over 1000 Amp. $373.00 $ Branch Circuit W/Service Feeder $5.00 $ Branch Circuit W/O Service Feeder $63.00 $ Each Additional Branch Circuit $5.00 $ Branch Circuits 1-4 $7500 $ Temp. Service/Feeder 200 Amp. $93.00 $ Temp. Service/Feeder 201-400 Amp. $110.00 $ Temp. Service/Feeder401-600Amp. $149.00 $ Temp. Service/Feeder601-1000Amp. $168.00 $ Portal to Portal Hourly $96.00 $ Signal Circuit/Limited Energy-1&2 DU $64 00 $ Manufactured Home Connection $120.00 $ Renewable Elec. Energy: 5KVA System or less $102.00 $ Thermostat(Note:$5 for each additipnal) $56.00 $ . ;. oF rss.. , N ,,._ er . - Owner as defined by RCW 19.28.261: (1)Owner will occupy the structure for two years after this electrical permit is finalized.(2)Owner is required to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection. After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I am making the electrical installation or alteration in compliance with the electrical laws, N.E.C., RCW.Chapter 19.28,WAC. Chapter 296- 46B,The City of Port Angeles Municipal Code, and Utility Specifications and PAMC 14.05.050 regarding Electrical Permit Applications. 12/14/2020 Andy Cochrane Date Print Name Signature(❑ Owner E' Electrical Contractor/Administrator) [Electrical Permit Applications may be submitted to City Hall or electricalpermits@cityofpa.us or faxed to 360.417.4711] ,xM Solar Agent: Michael Slater Client Name: Frazier Residence Power Trip Energy Corp 83 Denny Ave, Port Townsend, WA 98368 (360)643-3080 www.powertripenergy.com LIC: POWERTE964JN Project: Frazier Residence Client: Deborah Frazier Phone: (360)477-7762 Address:3115 City Lights Place,Port Angeles,WA 98362 System Description:7 Residential Grid-tied PV Solar Modules: Branch Circuit A-12 SunPower 350W AC modules AC Circuit Combiner Panel: Model: SPR-X21-350-AC-BLK Exterior north wall of garage Micro inverter max power output 320 watts House roof Solar Modules: Branch Circuit B-8 SunPower 350W AC modules Model: SPR-X21-350-AC-BLK Micro inverter max power output 320 watts House roof AC System Disconnect: (For Rapid Shutdown of AC Modules) Exterior north wall of garage Utility Grid:City of Port Angeles Net Meter: Exterior north wall of garage Meter#:31S9 Customer Owned Production Meter: Exterior north wall of garage Main Service Panel (LOAD): Interior north wall of garage December 14,2020 -3- Solar Agent: Michael Slater Client Name: Frazier Residence Power Trip Energy Corp 83 Denny Ave Port Townsend,WA 98368 (360)643-3080 www.powertripenergy.com LIC: POWERTE964JN Project: Frazier Residence, Client: Deborah Frazier Phone: (360)477-7762,Address: 3115 City Lights Place,Port Angeles,WA 98362 System Description: 7 Residential Grid-tied PV Project Photos and Notes: 111 South facing roof line of house-Location of 20 SunPower 350 W AC modules December 14,2020 -4- z Solar Agent: Michael Slater Client Name: Frazier Residence There is attic space at the top of the roof line. A piece of conduit(in red) can run up the roof along side of the skylight to the upper 5 modules, and then into the attic space available for the final run to the breaker panel located on the north interior wall of garage. Exterior north wall of garage- Location of utility meter,combiner panel,AC disconnect, production meter and data monitoring. Breaker panel is located on the interior of this wall. 4� December 14,2020 -5- 'emw ' Solar Agent: Michael Slater Client Name: Frazier Residence Y I4�S J 2 n 24p4 3 c�sxs:Gaw a x.2 * x nab , fN x ' Ys Square D homeline. Space needs to be made for PV breaker. Two open poles at top of panel are empty. December 14,2020 -6- Y Solar Agent: Michael Slater Client Name: Frazier Residence 19 l" � t t� December 14,2020 -7- Solar Agent: Michael Slater Client Name: Frazier Residence Exterior north wall of garage-Location of utility meter,combiner panel,AC disconnect, production meter and data monitoring. Interior north wall of garage-Location of breaker panel s 3D South facing roof line of house-Location of 20 SunPower 35OW AC modules. December 14,2020 -8-