Loading...
HomeMy WebLinkAbout709 E 1st St - BuildingMEMO COMMUNITY ECONOMIC DEVELOPMENT Nathan West Director 417 -4751 Sue Roberds Planning Manager 417 -4750 Scott Johns Associate Planner 417 -4752 Roberta Korcz Assistant Planner 417 -4804 Jim Lierly Building Inspector 417 -4816 Linda Pangrle Permit Technician 417 -4815 Patrick Bartholick Compliance Officer Building Inspector 417 -4712 Derek Beery Archaeologist 417 -4704 Fax. 360- 417 -4711 LI ES W A S H I N G T O N U S A DATE December 24, 2009 TO Public Works Engineering FROM Sue Roberds, Planning Manager RE Wolfley /Pursely Parking Lot Improvement 709 E 1St Street The plan to create a parking lot split between two adjacent commercial uses in the Commercial Arterial zone The parking lot will provide much needed off street parking for two adjacent commercial uses that have historically largely depended on street parking for customer use The plan does not pose any land use issues, in fact, resolves existing ones Thank you for the opportunity to review and comment ~ ~ORr """ 84.0~(C(~ rHii L -=- ~ 'tOi:,,~ CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY DEVELOPMENT - BUILDING DIVISION 32\ EAST 5TH STREET, PORT ANGELES, WA 98362 LaserBd CED Appl~cat~on Number Application p~n number Property Address ASSESSOR PARCEL NUMBER. Appl~cation type descr~pt~on Subdiv~s~on Name Property Use Property Zoning Application valuation 07-00000395 Date 446610 709 E 1ST ST 06-30-00-5-1-2255-0000- DEMOLITION 7/30/07 COMMERCIAL ARTERIAL 1000 Owner Contractor PURSLEY KEVIN/PAMELA 819 W 5TH ST PORT ANGELES MORRISON EXCAVATING INC POBOX 3051 WA 98363 PORT ANGELES WA 98362 (360) 452-7179 Structure Informat~on 000 000 ---------------------- TYPE V NON - RATED SINGLE FAM & CONGREGATES Construction Type Occupancy Type Perm~t DEMOLITION Addit~onal desc DEMO 1448 SFR Perm~t p~n number 99689 Permit Fee 50 00 Plan Check Fee 00 Issue Date 7/30/07 Valuation 1000 Exp~rat~on Date 1/26/08 Qty Un~t Charge Per . Extension BASE FEE 50 00 Fee summary Charged Paid Cred~ted Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 50.00 50 00 .00 .00 Plan Check Total 00 .00 00 00 Grand Total 50.00 50 00 .00 00 A I1tt led. 6 ~ 31/07 Separate Permits are required forelectncal work, SEPA, Shoreline, ESA, utilities, private and public improvements. ThiS permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work as commenced, or If required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a perl')1lt does not presume to give authonty to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Signature of Owner (If owner IS bUilder) Date T IPohcleslll02_15 bulldmg penmt mspectlOn rccord05 wpd [1/4/2005] Bun,DING PERMIT INSPECTION P...ECORD o ..J , oJ ..I:J \i\ CALL 4] 7-48] 5 FOR BUILDING INSPECTIONS CALL 4] 7-4735 FOR ELECTRlCAL INSPECTIONS CALL 4] 7-4807 FOR PUBLIC WORKS UTILITIES PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE IT IS UNLA WFUL TO COVER, INSUL/,TE OR CONCEAL ANY WOFJ( BEFORE I1VSPECTED AN]) ACCEPTED. POST PERMIT IN A CONSP1CUOUS LOCA TJON. KEEP PERMIT CARD AND APPROVED PLANS AT lOB SITE INSI'ECTION TYPE DATE ACCEPTED COMMENTS YES NO FOUN[)A nON FOOTINGS SHEAR WALLS / WALLS FOUNDA TION DRAINAGE / DOWN SI'OLJTS PIERS POST HOLES (POLE BLDGS ) PLUMBING UNDER FLOOR / SLAB ROUGH-IN WATER UNE (METER TO BLDG) GAS LINE FJNAL DATE ACCEPTED BY BACK FLOW / WATER AIR SEAL WALLS CE1LING FRAMING JOISTS / GIRDERS SHEAR W ALL/HOLD DOWNS WALLS / ROOF / CEILING DRYWALL (INTERJOR BRACED PANEL ONLY) T-BAR INSULATION SLAB WALL / FLOOR / CEILING MECHANICAL ROUGH-IN HEAT PUMY IFURNACE/DUCTS GAS LINE FINAL DATE ACCEPTED BY WOOD STOVE / PELLET / CHIMNEY MANUFACTURED HOMES FOOTING / SLAB BLOCKING & HOLD DOWNS SKIRTING PLANNING DEPT SEPARATE PERMJT#'s SEPA PARKING/LIGHTING ESA LANDSCAPING SHORELINE FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED YES NO ELECTRJCAL- LlGHTDEPT 417-4735 ELECTRJCAL LIGHTDEPT CONSTRUCTION - R W - CONSTRUCTIONR W /PWI ENGINEERING 417-4807 PW 1 ENGINEERING FIRE 4J 7-4653 FIRE DEPT PLANNING DEPT 417-4750 PLANNING DEPT BUILDING 4]7-4815 0/7'3IID'1 3"L-l BUILDING -J o ...,S) ft"\ (J\ -r f o ::c ..c OQ VI ~ T IPol,clesll J02 15 bm1dmg penn I! JJJspecnon recDld05 wpd [1/4/2005J <... PREPARED 7/31/07, 8 32 03 CITY OF PORT ANGELES ADDRESS CONTRACTOR OWNER PARCEL APPL NUMBER INSPECTION TICKET INSPECTOR JAMES LIERLY PAGE DATE 709 E 1ST ST MORRISON EXCAVATING INC PURSLEY KEVIN/PAMELA 06-30-00-5-1-2255-0000- 07-00000395 DEMOLITION SUBDIV PHONE PHONE (360) 452-7179 PERMIT, DEMO 00 DEMOLITION REQUESTED INSP TYP/SQ COMPLETED RESULT DESCRIPTION RESULTS/COMMENTS ~ -------------------------------------- COMMENTS BL99 01 7/31/07 (( " BLDG FINAL 07/30/2007 03 18 PM LPANGRLE DAN MORRISON STATED THAT THE HOME HAS BEEN DEMOLISHED BLDG FINAL 10 7/31/07 AND NOTES -------------------------------------- r- CJ~ rnC/') a("Q Qj Q \. ~n':;' \,' > \~j ~. '~ ~< , ' ,',\ ..' :,' l' .. '~! . .~ /:" \ .\,,:.'<':, '~',' ~ORTANGELES 0 0 ..J:::: .....l \ Lasered ~ VJ CEO - 0 ...I:J -J \/\ WAS H I N G TON, U. S. A PUBLIC WORKS & UTILITIES DEPARTMENT April 17, 2007 Morrison Excavation P.O. Box 3051 Port Angeles, W A 98362 RE: Port Angeles Transfer / Landfill Waste Disposal Application, WDA 07-16; Building demolition at 709 East 1 st Street, Port Angeles, W A We have received your application for disposal of building demolition debris from the referenced site and reviewed the testing results for lead content. Based on the testing results the debris appears to be acceptable for use in the landfill. A copy of your approved application is attached. This approved application must be shown to the landfill scale attendant at the time of disposal. Please be advised that this disposal application is only for the materials and quantities listed in the application. Materials not listed or in excess of the quantities noted may require separate applications and approval. , . : :>". <;:' Please call if you have questions. ) ';c ','" , _', ' ".,1 '.: ,;, ";:1' Very truly yours, '. ;' : \:~ ' ' . ~ ,!. ' '1'_;',1 '> '- , _/ 'I ,<,]' 'j . '" " ',l "'" ,", ' . " . ~ ", " ,,' ' " . "~ ' J/UA<L~ ~ r Gary W. Kenworthy, P.E. City Engineer Deputy Director of Engineering Services GWKtf Enel WOA 07.16 Copy Claudla Stromskl Bldg Ftle N IPWKSIENGINEER\WOAPPLlC\07.16 Ftle Landfill Sohd Waste Disposal Appheatlons 321 EAST FIFTH STREET. POBOX 1150 · PORT ANGELES, WA 98362-0217 PHONE 360-417-4805. FAX 360-417-4542. TTY 360-417-4645 E-MAIL publlcworks@cltyofpa US ~ ~ ~ --- ~ :,"/ " ; LvDA- 07- t /tt7 Laserw' CEf' PORT ANGELES LANDFILL WASTE DISPOSAL APPLICATION To: City of Port Angeles, City Engineer 321 E Fifth Street P.O. Box 1150 Port Angeles, Washington 98362 Phone: (360) 417-4803 FAX: (360) 417-4709 1. Generator Information: NOTE: All questions must be answered for waste to be approved. Company Name: Mailing Address: Phone: Project Name: Project Location: I1~S()tJ €~~-1J( P. b. i!:A ~ b/):S" ( /1;2"1 A.1J~kU.<', wA '7ffll. z '1S:::J, ({7 'f f5t/1c..6w..Jt ~o 709 Ii.AS~ f V -Y~"'t:" 1M- '7 AW(["i.L.cS , 2. Other Contacts (if applicable): Consulting Firm: 2vvovlc.-1 A.rsoc., ~c. , Contact: 7~'1' tC~ Phone: '1. (? - os- () I Contractor Name: Contact: Phone: Laboratory: Contact: Phone: M ~'tc s v.J 6ofC"'''o(J-1'~ ~Io/V M~.(~ YS1'1/?r IV V L L4d ,~~~-<~ rt:vc A:",^'\~ -:J 2 7A., ?d6 ~Cff ...d (J " City of Port Angeles - Landfill Waste Disposal Application Wed, 1 0/4/2006 0 4 PM Page - 1 , \:o.s'G~'G~ rvs'0 ~ 3. Source of Waste: Check the appropriate box below and briefly describe the project, process, and/or cleanup that will or has produced the waste requiring disposal. Include the gasoline service station number (if applicable). CERCLAlMTCA Remediation Independent Remedial Action Unused Chemical Product Spill Agency Contact: UST Removal ~ Other Source: J)'tMDLI. -I,vJ 4. Waste Material Composition: (check all that apply and include percent of total) Soil - % _ Foundry Slag - % Concrete/Asphalt - % _ Dredge Sediments - % Preserved Wood - % ~ Debris .l.1A:L % Coal Ash _% _ Other (list) Wood Ash - % - % _% NOTE: Total must equal 100%. 5. Waste Material Contaminants: (check all that apply) NOTE: Gasoline Metals Solvents _ Heating Oil Unused Motor Oil Used Motor OillWaste Oil Other ~o/.n -feif 69 Other Petroleum Product /~4o(&?o~ I.ly ()~~ - '.: f\.b MO~-1&.s V1)JNQ Unknown Supply any MSDS information with application, if available. Diesel PCBs -L City of Port Angeles - Landfill Waste Disposal Application Page - 2 Wed, 10/4/200604 PM .. ,J Lasered CEO 6. Estimated Quantity of Waste for Disposal: 2<; Cubic yards / Drums / liD Tons (estimate both) Tons (estimate both) Other NOTE: Estimated quantity for disposal must be within 20% of the quantity actually disposed. (10% for projects over 7,500 tons or 5,000 cubic yards.) 7. Frequency of Disposal: -K. One time _ Monthly Annual Other 8. Waste Sampling: Proper characterization of the waste for disposal requires the collection of representative samples. The methods and equipment necessary for obtaining representative samples of a waste, and the frequency of sampling, will vary with the type and form of the waste. Check the appropriate box and briefly describe how and where the waste was sampled. Include site maps with sampling locations if possible. Number of COMPOSITE samples --L & number of discrete samples per composite S I Number of DISCRETE samples -5 70 ~ NOTE 1: Unless prior approval has been granted by Port Angeles, the following sampling frequency will be used: 0-25 cubic yards = 25 - 100 cubic yards = 101 - 500 cubic yards = 501 - 1000 cubic yards = 1001 - 2000 cubic yards = >2000 cubic yards = NOTE 2: One composite sample shall discrete samples. 1 composite sample 3 composite samples 5 composite samples 7 composite samples 10 composite samples 10 plus one sample for each additional 500 cubic yards contain a minimum of three/maximum of five City of Port Angeles - Landfill Waste Disposal Application Page - 3 Wed. 1 0/4/2006 0 4 PM ~~~ 'v 'O-S~<.v'\) .. 9. Waste Analysis: The "Dangerous Waste Regulations" (WAC 173-303) shall be utilized to determine the appropriate analytical requirements for waste characterization. Ecology Publication #91-30 (Revised April 1994) "Guidance for Remediation of Petroleum Contaminated Soils" shall also be used to characterize petroleum contaminated soils from UST releases. Submit all laboratory analytical results, QA/QC data, and Chain of Custody sheets along with this application. (NOTE: The laboratory must be accredited by the Washington State Department of Ecology. ) a) List all antytical test methods used: tt}A 1~1I ., ~~ b) Provide a narrative as to why the above an ytical methods were selected: ~0It ~ :.{ H,A-1~ ,- S/(o -r7' ~ ~ lJ~ f AtA-r o.J ~~ s=?4l..t:'?'v-e'f. NOTE: Additional sheets attached: YES NO 10. Soil Classification: (-FOR PETROLEUM CONTAMINATED SOILS ONLY**) Based on the analytical data and Ecology Publication #91-30, the soil classification is: (check one) Class 1 Class 2 Class 3 Class 4 Calculated Hazard Index 11. Dangerous Waste Affidavit: Based on a review of the analytical test results, site history, and the applicable regulations, this waste is classified as: (check one) ~ Neither Dangerous Waste (OW) nor Extremely Hazardous Waste (EHW) Dangerous Waste (OW) and Waste Code: Extremely Hazardous Waste (EHW) and Waste Code: City of Port Angeles.. Landfill Waste Disposal Application Page - 4 Wed, 1 0/4/2006 0 4 PM Lasered CEO 12. Certification: enerator Signatu -4<<7 6u<J~<<- Printed Name 2~~'hC- " ASS'~(, J.v'C Company ~ h3/l) '/ Date City of Port Angeles Approval: <-~4'('a. ~,/,vVcurA:~~ IE: City Engineer tJ :> 1- /1-07 Date f-/7-07 Approval Expiration Date City of Port Angeles - Landfill Waste Disposal Application Page - 5 Wed,10/4/2006 0 4 PM APR. 13. 2007-10:26AM-NVL LABORATORIES INC NVL Laboratories, InclI 4708 Aurora Ave. N.. Seattle, WA 98103 Tel: 206.547.0100, Fax: 206.634.1936 www.nvllabs.eom Las~~e6 CED NO. 9261-P. 2 . ~ AIHA -IH # 101861 ACCIUIDIT.D WA . DOE # C176S LA80llAYORY ~ Anal sis Report Toxicity Characteristic Leaching Procedure - Lead (Pb) Client: Zenovic & Associates, Inc. Address: 301 E. 6th St. Suite 1 Port Angeles, WA 98362 Batch #: 2705940.00 Matrix: Bulk Method: EPA 1311nOOOB Client Proiect #: 07063 Date Received: 04/1112007 Samples Received: 1 SamDles Analvzed: 1 Attention: Mr. Tracy Gudgel Project Location: 709 1 st East, Port Angeles Lab 10 Client Sample # 07063A RL mg/L 0.4 Results in mg/L 1.5 Results in ppm 1.5 27041106 Sampled by: Client Analyzed by: Ahmad Izzat Date Analyzed: 04/1312007 DRAFT mg/ L =Milligrams per liter RL = Reporting Limit ppm = parts per million '<' = Below the reporting Limit Note: Method QC results are acceptable unless stated otherwise. Unless otherwIse indicated, the condition of all samples was acceptable at time of receipt. APR. 13. 2007 10: 27 AM NVL LABORATORIES INC CHAIN of CUSTODY SAMPLE LOG NO. 93~ ]rc~~'I) 2705940.00L~~~ed ~ I 4708 Aurora Ave N, SeaUIe. WIA 881Ga. Tel; 206,547.0100 Emera. Pager. 206.344.1878 t,888.NVLLABS (885.5227) OIlent Zenovic & AsSOCIates, Inc. NVL aatDh Number StrHt ~a 0\ Go;. "" ~ ~,~ ~ l CltentJob Number (5'21) {,3 Port Angeles Total Salllp1e8 ----1- ProjectlllaMge '~"'I C~.J~~~ TumAroundTd1Ie 0 1-Hr D~rs 04 Days PfOject ~.: 7G)CJ ,1d '~~., PNL'f' A.v4'4df.s, B~: m g:: Sg ~~ Davs I PlnsD CIII forTAT IiiI U. zc HIS em_a....... ~.A_ iL?~"""'~ AlA~ PhOne: (360) 417-0501 Fa: (360) 417.o5~4 fo ~beItOI Air I Cl PCM (NIOSH 7400) 0 ll;M (NIO" 7402) tJ TEM (AHEM) 0 TEM tEPA L.Svel II) 0 0Iber CI ACes. Bt,dk o PlM (EPAI8OOIR-131118l CI PLM (l!PA Point Count) 0 PLM (EPA Gramumy) 0 TEM Bulk METALS ~k 118trbr: ReRA ..... Cl AI e _I' ~ Metatt (A/'S) I:l Nr Filter 0 Patnt Chips o Anienic (As) 0 Lead (Pb) U All a CLP o ppb (GFM) a Drinking water 0 Paint CI1Ip$ (Areo) o Barium (Ba) 0 Merttlry (Ha) DCGpper(Cu) U Duatlwlpe 0 Waste water o cadmILIm (Cd) Cl Setenfum (88) CI Nickel (WI') CJ SolI o Chron'IiUIn (Cr) CI SilVer (Ag) o ZInc (Zn) o Other Types Cl FbItgJaIs 8 ~lsance DU&t 0 Rotometer Calibtedon 0 Other '(Specify) , of Analysis o Sica RespIrable Du5l CJ MaldlFunaWl AIR $8mpIed by Reli~ ReceIved by , AnaIp:ed by Results Called by Results Faed by Special ntructions: Unless requested in writing. aU liampl. wiD be di~d-d ~ (2) weekS after analytis. ft~ ~ .e,,"ul.-t'S ~ \... ..../ '.