HomeMy WebLinkAbout1730 E 3rd St - Building ~ ""ORT ~ $:.J.O~~~ rea ~ -- ~-:;--~ CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY DEVELOPMENT - BUILDING DNISION 321 EAST 5TH STREET, PORT ANGELES, WA 98362 LCasere(/ 'ED 12/30/05 Application Number Application pin number Property Address ASSESSOR PARCEL NUMBER: Tenant nbr, name Application type description Subdivision Name Property Use Property Zoning . . . Application valuation 05-00001252 Date 669996 1730 E 3RD ST 06-30-00-5-5-0105-0000- FRANK FRITZER RES ADDITION Fl~eo 0/~/oh RS7 RESDNTL SINGLE FAMILY 3000 Owner Contractor FRITZER FRANK P 904 S F ST PORT ANGELES OWNER WA 983635520 Other struct info . TOTAL % LOT COVERAGE NUMBER OF STORIES EXISTING LOT COVERAGE LOT SIZE PROPOSED LOT COVERAGE TOTAL LOT COVERAGE NUMBER OF UNITS 29.10 1.00 1640.00 7000.00 400.00 2040.00 1.00 Permit . . . . . Additional desc . Permit pin number Permit Fee Issue Date Expiration Date BUILDING PERMIT -RESIDENTIAL 68080 109.75 12/30/05 6/28/06 Plan Check Fee Valuation 43.90 3000 Qty Unit Charge Per Extension 95.75 14.00 BASE FEE 1.00 14.0000 THOU BL-2001-25K (14 PER K) Special Notes and Comments The Fire Department has reviewed the project application and has no comments 12/29/2005 12:28 PM SROBERDS -- The proposal is to add a storage shed to an existing residence in the RS-7 zone. No land use issues are noted. $0 Connect Fee. 12/21/2005 07:34 AM JHEBNER ---------------------------- Public works electrical engineering has no requirements for this plan review. Any modifications to the City'S electrical facilities will be at the customer's expense. Public Works Uti11ty Eng1neering has no requirements for this plan review. Other Fees STATE SURCHARGE 4.50 Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 109.75 109.75 .00 .00 Plan Check Total 43.90 43.90- .00 .00 Other Fee Total 4.50 4.50 .00 .00 Grand Total 158.15 158.15 .00 .00 ~ \ ~ ~ \? - -l ~ \) (\'\ ~ ~ ~ Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public Improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating struction or the performance of construction. ~ Signature of Contractor or Authorized Agent Date Signature of Owner (if 0 T:\PohCles\1102_15 buildmg pennlt mspectlOn record05 wpd [1/4/2005] \ BUILDING PERMIT INSPECTION RECORD CALL 417-4815 FOR BUILDING INSPECTIONS. CALL 417-4735 FOR ELECTRICAL INSPECTIONS CALL 417-4807 FOR PUBLIC WORKS UTILITIES PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE IT IS UNLA WFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE. INSPECTION TYPE DATE ACCEPTED COMMENTS YES NO FOUNDATION: FOOTINGS WALLS FOUNDATION DRAINAGE 1 DOWN SPOUTS PIERS POST HOLES (POLE BLDGS ) PLUMBING UNDER FLOOR 1 SLAB ROUGH-IN WATER LINE (METER TO BLDG) GAS LINE FINAL DATE ACCEPTED BY BACK FLOW 1 WATER AIR SEAL WALLS CEILING I FRAMING JOISTS 1 GIRDERS SHEAR W ALLIHOLD DOWNS WALLS 1 ROOF 1 CEILING DRYWALL (INTERIOR BRACED PANEL ONLY) T-BAR INSULATION SLAB WALL 1 FLOOR 1 CEILING I MECHANICAL HEAT PUMP 1 FURNACE 1 DUCTS GAS LINE WOOD STOVE 1 PELLET 1 CHIMNEY FINAL DATE ACCEPTED BY' COMMERCIAL HOOD 1 DUCTS MANUFACTURED HOMES FOOTING 1 SLAB BLOCKING & HOLD DOWNS SKIRTING PLANNING DEPT. SEPARATE PERMIT #'s SEP A- P ARKINGILIGHTING ESA LANDSCAPING SHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCYIUSE RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED YES NO ELECTRICAL - LIGHT DEPT 417-4735 ELECTRICAL LIGHT DEPT CONSTRUCTION R W 1 PWI CONSTRUCTION - R W ENGINEERING 417-4807 PW 1 ENGINEERING FIRE 417-4653 FIRE DEPT. PLANNING DEPT. 417-4750 I J PLANNING DEPT. BUILDING 417-4815 ~f.'H'" //'J/. \flA-- BUILDING T:\Pohcles\1 102_15 bUlldmg peront mspectlOn record05 wpd [1/4/2005] PREPARED 9/26/06, 10 08 49 CITY OF PORT ANGELES INSPECTION TICKET INSPECTOR JAMES L LIERLY , PAGE DATE 3 9/26/06 ADDRESS TENANT, NBR CONTRACTOR OWNER PARCEL APPL NUMBER 1730 E 3RD ST FRANK FRITZER SUBDIV FRITZER FRANK P 06-30-00-5-5-0105-0000- 05-00001252 RES ADDITION PHONE PHONE PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS Lasered CEO BL99 01 5/09/06 5/10/06 JLL DA BUILDING FINAL TIME 13 00 05/08/2006 09 37 AM DYASUMUR --------------------------- FRANK 457-9449 05/10/2006 04 31 PM JLIERLY ---------------------------- No 1nspect1ons on slab before pour no 1nspect1on/]11 BUILDING FINAL TIME. 13 00 FRANK 670-1417, CALL FIRST TO MEET YOU AT PROJECT SITE 09/07/2006 08 44 AM DYASUMUR BL99 02 9/08/06 9/08/06 JLL DA BL99 03 9 -------------------------------------- COMMENTS AND NOTES -------------------------------------- 9/26/06 ,- 09/08/2006 04 32 PM JLIERLY ---------------------------- eng1neer letter reqd and complete work that lS requ1red by eng1neerIJ 11 BUILDING FINAL FRANK 457-9449 09/25/2006 09:17 AM PERMITS ---------------------------- F),NfOVnc & ASSOCIATES CML ENGINEERING LAND SURVEYING Lasered CEO 301 East 6th Street, SUite 1 Parr Angeles,Washlllgron 98362 (360) 417-0501 Fax (360) 417-0514 E-mall.zenovlC@olympus.net INCORPORATED August 31, 2006 ------- --------------- ~ (--- r~ & -----..... Mr. Frank Fritzer 904 South F. Street Port Angeles, W A 98362 SUBJECT: Shop Constructe Dear Mr. Fritzer: ort Angeles, Washington At your request this office performed a field inspection of the shop constructed at the address noted above to verify the foundation system for the new structure. Based on my site inspection and the documentation provided by you, the monolithic footings supporting the structure is of adequate depth and has proper reinforcing to support the required vertical loads imposed by the structure. To provide positive drainage away from the structure to conform to building code requirements it is recommended that a concrete apron be installed on the south and west sides of the structure. The apron on the south side shall extend from the building line to the block retaining wall and shall slope away from the building. The apron on the west side shall be a minimum of two feet wide and shall slope away from the structure. The existing lawn area on the west side shall be graded as necessary to direct runoff from the aprons away from the new structure. Please note that a complete framing inspection was not performed by this office. This inspection should be performed by the local building department. Please call me if you have any further questions on this matter. - ~ ~ W- ~ \~ Sf- Fc: IN 06229 FRITZER FRANK P 06-30-00-5-5-0105-0000- 05-00001252 RES ADDITION PREPARED 9/08/06, 10 30-57 CITY OF PORT ANGELES ADDRESS TENANT, NBR CONTRACTOR OWNER PARCEL APPL NUMBER: 1730 E 3RD ST FRANK FRITZER INSPECTION TICKET INSPECTOR JAMES L LIERLY PAGE DATE 8 9/08/06 SUBDIV PHONE PHONE Lasered CED PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL99 01 5/09/06 JLL 5/10/06 DA BL99 02 '/W"~ BUILDING FINAL TIME 13 00 05/08/2006 09 37 AM DYASUMUR --------------------------- FRANK 457-9449 05/10/2006 04 31 PM JLIERLY ---------------------------- No lnspectlons on slab before pour no lnspectlon/]ll BUILDING FINAL TIME 13-00 FRANK 670-1417, CALL FIRST TO MEET YOU AT PROJECT SITE 09/07/2006 08 44 AM DYASUMUR -------------------------------------- COMMENTS AND NOTES -------------------------------------- ft1~ ~1- l.- 't? vl/lld-'~tr \ ~C- "rf ~\ <... BUILDING DIVI~ION ~- II'::,~/ Lasered CEO CITY OF PORT ANGELES * * Correction Notice Job Located at /7 30 G -:s720 Inspection of your work revealed that the following is not in accordance with the codes governing the work in this jurisdiction: * JJo ~<;,.pe~~0 w (3-~-:- L r4-l1 IL.t ~~ ~ou~Dt-J~ g~eJ ~ - r~.:D~ ~~~ \.J:nt ~r~~/p These corrections must be made and are not to be covered until reinspection is made. When corrections have been made, please call L/ J 7 -Lj il r- for inspection. Date ~/, In fc, I , ~ Inspector for Building Division DO NOT REMOVE THIS TAG PREPARED 5/09/06, 9:22 38 CITY OF PORT ANGELES INSPECTION TICKET INSPECTOR: JAMES L LIERLY PAGE DATE 14 5/09/06 ADDRESS TENANT, NBR. CONTRACTOR OWNER PARCEL APPL NUMBER 1730 E 3RD ST FRANK FRITZER SUBDIV FRITZER FRANK P 06-30-00-5-5-0105-0000- 05-00001252 RES ADDITION PHONE PHONE PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS Lasered CEO BL99 01 ~~ BUILDING FINAL TIME 13 00 05/08/2006 09 37 AM DYASUMUR --------------------------- FRANK 457-9449 -------------------------------------- COMMENTS AND NOTES -------------------------------------- J ~ City of Port Angeles Applicant Project Review Sheet Lasered CEO ApplIcant: r::R A~ /.L H ; rzej( Owner. / \..\~ Property Address. Proposed Use' /?,?tJ E 3Ad fJie6)df">f\I Ii tL SfpfJ. e I} Ii Zonmg: _ Is the proposed use hsted as a "permItted use" or an "accessory use" In thlS zone? Is thIs the only use (bUSineSs,S etc.) on thIs sIte? Has there ever been a subdIvIsIOn, shortplat, or PRD approved for thIS sIte, or has one been submItted and IS pendmg approval? Does the proposed use reqUIre a new bUlsmess hcense? Does the project extend mto any requITed setbacks or cross any lot lmes (mtenor or extenor)? Does the proJ ect exceed the perrmtted heIght allowance or cause the property to exceed the allowed lot coverage in tills zone? Does the project reqUIre any addItIOnal parkmg or specIal design/landscape Improvements m tills zone? Does the project ellllllllate any eXIstmg parkmg spaces? Is the project located WIthin 200' of the shorelme? Are there any envIronmentally senSItIve areas on or wItilln 200' of the property, mcludmg: . wetlands or areas of standmg water (year round or seasonal); . streams (year round or seasonal), . areas WIth a slope of 40% or greater, or . areas that have eVIdence of past ground movement or eroSIOn? Have all ilie requITed subll11ttals been proVIded by the applIcant? o SIte Plan 0 Construction Drawmgs o Parkmg/Dramage Plan 0 CIvIl Drawmgs o Energy Calc 0 Supportmg Engr. Calc o Landscape/LIghtmg Plan 0 Oilier ~es: ok Ono. reqUITes PD reVIew ~ yes. ok o no requITes PD Dyes requIres PD D no ok D yes. reqUIres CC ij( no ok reVIew D yes' reqUITes PD Jano' ok reVIew D yes: reqUIres PD r4no: ok reVIew D yes: requires PD ~no, ok revIew D yes' requITes PD ~o'ok reVIew D yes' reqUITes PD iX.no' ok reVIew Dyes' reqUITes PD .;g! no: ok reVIew If Planlllng Department reVlew is required, the processlllg tlme may be extended Iflt lS determllled a separate Planning Department permlt(s) lS needed, the Plannll1 De artment ernut(s) must be a roved nor to the lssuance of any other ermlt The lI1formatLOn provlded above is true to the best of my knowledge, I understand that 1Il the event that any of tIllS lIlformatLOn is determllled by the CIty to be lIlcorrect, thls pro 'ect will be stopped until such time the CIty determll1es the correct informatLOn is provided and any subsequently re lred rev' (::j 'Ppro s are completed and granted; /) /~-/?-6S- Applicant Date Permlt Category # Route to: 0 BD Staff ImtJals (see reverse side) o CC 0 FD 0 LD BUIlding PermIt # o PD 0 PW 0 FIle Master Trackmg # o Other Date CompletIon of tIllS form lS reqUlred for all category 1 b, 2 & 3 pernuts CompletLOn lS not requlred for \..ase~ed CEt\) '\, ~, ", I I I I Feel Vertical Datum c NA VD 88 Harrwntal Datum c NAD 83/91 I N Area Map ff This map IS not intended to be used as a legal descriptIOn t::!!:!!:.S This map/drawmg is Ploduced bv the Otl' of Port Angeles f01 Us own llse and purposes lr ~I Any other lIse of this map/dra>>mg shall not be the responslbt{'~l of the Cu\' ~i A ~0\~[)11T'1\.(,(( ~, ,:::..." '...'~ - .(J '-' -;1+" _r' I~'- -..- ~ - ~) .,,, .-~ r:' }J:","~m~ ~ - - ,--- ,~ ". - ~~-,-~ ~ ,.. ...--~~ I "~/ lasered BUILDING PERMiT - APPLICATION CED ," Fill out COMPLETELY and in INK. Your applIcation and site plan l\1UST BE C()I\1PLETE, Tn he aCLepLeu lur revie:~. If you have any questions, ~:lll PERMITS (360) 417-4815 FAX(360)417-4711 ~AN ApplIcant or Agent j- /? IlJ1lJ!. Owner .s:;:;/rJ e Address' 1130 F/;JJ' Tze~ Phone -::1 6 t) t; ~ 7 ~t;-!;- q 3itJ//JtJ /f/7 aEf Zlp 9K3tJ. E:3Rd Phone Clty. foR f J)N9c:'./e..~ luchItect/Engmeer Contractor Phone: State Llcense #' Exp Phone Address: CIty: PROJECT ADDRESS J 730 E, 3 I<d, LEGAL DESCRIPTION: Lot j Block )0 tJ CLALLAM COUNTY PARCEL NUMBER dc. <5 0 ZIp' ZONING: SubdIVISIOn' fiidfJRd)F:G- S' u !J bh S-St1/LJS--9g L1tr TYPE OF WORK: ~Resldentlal 0 New Consrr 0 Re-roof o MultI-family ~ddmon 0 Move o Connnerclal 0 Remodel 0 DemohtlOn o Reparr 0 SIgn BRIEF DESCRIPTION OF THE PROJECT SIZENALUATION: o Stove SF @ $ /SF =.'); o Garage SF @ $ /SF =.'); o Deck SF, !2V, $ /SF =.'); )(Other TOT.A.L '\Ti>.LUATION X$ /s () () 0,60 5" tIJ R.1t7e ~C: led 1}#jlrJecJ /h (b'/6/..t;e COMJVIERCL1\L/RESIDENTIAL: Occupancy Group No of Stones _ Lot SlZe. 5"0 xl4-0EXlstmg Sq Ft Total lot coverage~ . Occupant Load I/, t;-/J & Proposed Sq Ft Construcnon Type (/Jpo(j FjJ .4ftl e.- ~!) 0 = TOTi>.L Sq Ft. a tJ 'to APPROVALS: PLAN: BLDG: DP"WU: FIRE: OTHER:_ PLANNING USE ONLY: ESAfW etland( s): 0 Yes 0 No SEP A Checkhst requrred? 0 Yes 0 No Othel VALUATION OF CONSTRUCTION In all cases, a valuation amount must be entered by the apphcant Tlus figure wIll be revIewed and may be revIsed by the Buildmg DIVlslOn to comply WIth current fee schedules COlltact the Pernnt Coordmator at 417-4815 fOl aSSIstance. PLAN CHECK FEE IF a plan check fee IS due It must be subnntted at the tnne the bUlldmg pemut apphcation and construcnon plans are subnutted. All other pernnt fees are due at the tm1e of pemut issuance EXPIRA..TION OF PLAN REVIEW: !fno perilllt IS Issued Wlthm 180 days of the date of apphcatlOn, the application will expire. The BUlldmg OfficIal can extend the tm1e for actlOn by the apphcant up to 180 days upon wntten request by the applicant (see SectlOll RI 05.3.2 of the IntematlOnal Bmldmg/Resldennal Code, 2003). No applicanon can be extended mOle than once I hereby certify that I have read and exammed thiS appiJcation and know the same to be true and correct. I am authorjzed to apply for thiS permJt and understand that H IS my respons/bJiHy to determ' what permUs ar; ired ,not the City'S, and that I must obtain such permits pnor to work Date: J:;J-:/6'-a~ T \Pohcles\BL-Il 02_13 wpd Applicant: