HomeMy WebLinkAbout805 E 2nd St - BuildingPREPARED 5/17/10 8 45 03 INSPECTION TICKET PAGE 3 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 5/17/10 ADDRESS 805 E 2ND ST SUBDIV TENANT NBR DONALD /BOBBIE EDGMON CONTRACTOR PHONE OWNER DONALD /BOBBIE EDGMON PHONE (360) 460 0204 PARCEL 06 30 00 5 1 2430 0000 APPL NUMBER 09 00000101 RES DETACHED GARAGE PERMIT DF3 00 BUILD PERMIT RES DBL FEE REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BLFO 01 3/26/09 JLL BLDG FOUNDATION 3/26/09 AP March 26 2009 10 58 39 AM 1pangrle FOUNDATION WILL BE ACCEPTED UPON THIS REPORT FROM KRAZAN ASSOCIATES DATED 03 09 09 SEE REPORT ON FILE March 26 2009 11 00 19 AM 1pangrle BL99 01 5/17/10 Jj BLDG FINAL TIME 01 00 JV May 13 2010 9 38 49 AM 1pangrle DON EDGMON 460 0204 BUILDING FINAL GARAGE AFTERNOON PLEASE CALL HIM 30 MINUTES BEFORE YOU GET THERE SO HE CAN MEET YOU THERE COMMENTS AND NOTES Application Number Application pin number Property Address ASSESSOR PARCEL NUMBER Application type description Subdivision Name Property Use Property Zoning Application valuation Application desc 1 circuit for detached garage Owner Edgeman Don 805 E SECOND ST PORT ANGELES Permit Additional desc Permit pin number Permit Fee Issue Date Expiration Date Fee summary Permit Fee Total Plan Check Total Grand Total INSPECTION TYPE DITCH SERVICE ROUGH IN FINAL COMMENTS WA 98362 151654 57 50 8/,19/09 2/15/10 ELECTRICAL PERMIT CITY OF PORT ANGELES 360 417 -4735 09 00000818 448160 805 E 2ND ST 06 30 00 5 1 2430 0000 ELECTRICAL ONLY RESIDENTIAL HIGH DENSITY 0 Contractor ELECTRICAL ALTER RESIDENTIAL SHAMP ELECTRICAL CONTRACTING PO BOX 383 PORT ANGELES (360) 452 1689 Plan Check Fee Valuation Qty Unit Charge Per 1 00 57 5000 ECH EL R OUTBD /DTCH GAR IN /SEP Special Notes and Comments MAINTAIN CLEARANCES FROM SERVICE WIRES August 17 2009 11 05 53 AM Bob Larson 360 417 4706 City owned supply triplex must have 3 0 minimum clearance over garage roof while the conductor is under loaded conditions (1/4 of ice on wire no wind or conductor heated to 120 degrees F no wind Whichever produces the most sag) Charged Paid Credited 57 50 57 50 00 00 00 00 57 50 57 50 00 S -IL /o S• !Z to Date 8/19/09 WA 98362 Due DATE. RESULTS 00 00 00 00 0 Extension 57 50 Signature of owner or Electrical Contractor X Date INSPECTOR. V u) 3n 08/13/2009 15 46 FAX City of Port Angeles Permit Application Building Division /Electrical Impactions 321 East Fifth Street P 0 Box 1150 Port Angeles Washington, 96362 Ph (360) 417-4735 Fax (360) 417.4711 Date J 1 2 Single Family Dwelling Multi- Family o^ Commerc al' Commercial Addition /Alteration Remodel Repair' Plan Review Ma 3. Requed P ese o tele E ctncal v`ev�6o41' Stec Job address Yj(y� Building Square Foolage Description of above 1 �4C -I�.�p C.-be-Pt (4:» t 1 2 W L t Unit Charge 9.75 $113 75 $160 00 $205 00 529125 2.00 L .00 72.50 86.25 $11625 513 25 75 00 69 00 75 00 50 00 5 5000 95 75 60.00 86 25 2750 57 50 86 25 43.75 Owner Infor •l ion Nance: Mai ing City Phor> been x X i State: ax: Signature of owner electrical contractor or electrical administrator C? Cash Zip: Date: RECE_VED AUG 1 2009 ELECTRICAL INSPECTIONS nation iarn0 �Cj Contractor Name. Mailin• •ddr-, City' 0 11r it /4 Phon-" 3M L,cens g Exp, gel (Qtv Multiplied by Unil Chars Service /Feeder 200 Amp. Service /Feeder 201.400 Amp. Service /Feeder 401-600 Amp Service /Feeder 601 1000 Amp ServicelFeeder over 1000 Amp Branch Circuit W/ Service Feeder Branch Circa W/0 Service Feeder Eac Ado lional Branch Groot Temp Service! Feeder 200 Amp Temp ServicelFeeder 201.400 Amp Temp ServicelFeeder 401.600 Amp Temp Service /Feeder 601 1000 Amp 5 Ponal to Donal Hourly S:gn!Ouiline Lighting Signal Circu'U Limned Energy Commercial r Signal Circu'U Limited Energy 1 2 Family Dwelling, Signal Cirou Limited Energy Multi Family Dwelling Manglaclured Home Connection Renewable Electrical Energy 5KVA System or Less First 1300 Square Ft. Each Additional 500 Square Fl or Portion or Each Outbuilding or Detached Garage Each Swimming Pool or i10t Tub Thermostat $4 Total 1_ Check m 001/006 It. V r' State Zip v I D Fax 7,000 Owner as defined by RCW '9.28 261 (1) Owner will occupy the structure for two years after this electrical permit Is finalized (2) Owner is •equlred ro hire en electrical contractor If above said property Is for sale, rent or lease, After reading the above statement, I hereby certify that I am the owner or the above named property or a licensed electrical contractor ern making the electrical Installation or alteration in compliance with the electrical laws, N.F.C. RCW Chapter 19.28, WAC Chapter 296.468 The City of Port Angeles Municipal Code ono Utility Specifications Credit Card# e eft #r Cizd,/ find ij iNi aZarz ASSOCIATES, INC GEOTECHNICAL ENGINEERING ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING INSPECTION March 9 2009 KA Project No 106 -09031 Mr Don Edgmon 805 East 2 Street Port Angeles, WA 98362 Methodology Foundation Elements Phone (360) 460-0204 Email dedgmon @olypen.com RE. Garage Foundation Survey 805 East 2nd Street Port Angeles, WA Dear Mr Edgmon. J< Ac U Polo Repatf In accordance with your request and authorization, Krazan Associates has completed a limited scope survey o reinforcing steel in the existing perimeter concrete foundation for the referenced 30 ft. by 30 ft. detached garage. The survey was conducted March 9 2009 using a James Instruments Rebar Plus' Pachometer serial number 9201012. The pachometer provides information to the operator through the transmission of a continuous electromagnetic signal generated via a hand -held wand as the wand is moved across the surface of the concrete being surveyed. Interpretation of the signal strength on an analog R -meter and an audible signal provide the operator with the information required to locate and identify embedded steel objects. Relative signal strength provides the operator with an indication of the position of and the apparent depth of concrete cover over the reinforcing. The Rebar Plus model pachometer is effective to a depth of 5 to 6 inches. The dimensions of the spread footing were verified by excavating alongside and underneath the footings along the West and South sides of the structure To observe the typical reinforcing steel patterns, pachometer scans were performed underneath and along the exposed footing locations and along the stem walls. The foundation system consists of a continuous reinforced concrete spread footing with a reinforced concrete stem wall, configured as follows. Typical footing dimensions appear to be 16 inches wide by a minimum of 10 inches thick. The stem wall measures 6 inches wide by 20 inches high. The stem wall is generally centered on the continuous footing, with 3 to 6 inches of footing concrete exposed in front of the stem wall. Concrete surface finish is relatively dense and appears to have been well consolidated during placement. With Offices Serving The Western United States 1230 Finn Hill Road, Suite A Poulsbo, Washington 98370 (360) 598 -2126 Fax. (360) 598 -2127 Summary Respectfully submitted, KRAZAN ASSOCIATES, INC. Jonathan aas roject M nager Pe su a Division Krazan Associates, Inc. Offices Serving The Western United States Edgmon Garage Rebar Survey KA Project No 106 -09031 March 9 2009 Page No 2 Rebar Survey The following indications of reinforcing steel were observed during the course of the survey Stem Wall. One continuous horizontal top bar positioned near the center of the stem wall. o The top bar appears to be positioned from 2 and 6 inches below the top of the wall Typical vertical bar spacing is 48 inches on center at all wall locations. o Vertical bars were also observed at wall ends and corners. o Vertical bars appear to have a horizontal hook embedded near the bottom of the spread footing. inch diameter sill anchor bolts appear to be embedded a minimum of 7 inches into the top of the stem wall. Rebar size appears to be minimum #4 bar based on pachometer signal strength and indicated cover Spread Footings. Two continuous horizontal bars were detected in the continuous spread footing. o Rebar appears to have a minimum of 3 inches of cover to the bottom and 4 inches to the outside formed faces of the footing Rebar size appears to be minimum #4 bar based on pachometer signal strength and indicated cover Based on the above observations, the stem walls and continuous footing dimensions and reinforcing steel details found in the subject structure generally conform to the requirements noted on the untitled "FDN PLAN" provided. Additionally the dimensions and reinforcing steel details appear to meet or exceed the minimum requirements for two story construction in accordance with the applicable provisions of the 2006 IRC Sections R403 and R 404 1 4 and Table R403 1 If you have any additional questions, or if we can be of further assistance, please do not hesitate to contact the undersigned. 1 l1 411 0 lu L' 6 L CU rt /f� f/ 15X4. 5:15 4>C8(B)° III Ln 11 LL (7H86 Lfo,H''N At i p c ho d 214 Hi 1C l 1 FE 1' t rho d ?rd 111 1655 1 SE 1,eb 2 4 IIF S1 d W3 N- 4 NI 1800f 1 bL AGUITt6N.t1. LOADS PC Fros 80 Pi 4 at 10 10 t 30 r&F t 19 tlyule En1n, -rej Ptodncts, fa Sa.,ammtu Ca 1 3 R 1414 4-31.4 W 3 5 3X5 3X5 x 5X7 3X5 ft W3 l 100 nth 7 .d 5 00 ft +mcan hgt .Ct I 42 cicsro ttc le Led 1 rc't Cc 1 YP C 1 n IC 0L -4 par WI °C 0t -6 0 pit IN 111.0 Cl 1R11CIJ1A1 P4PLLS OR FICI0 CII((NG U'L PURL INS CHUF0 .,P4CING(IN UC) TART (FT) I'NO(FT1 8t T20 r1 02 21 7 Trus da I p 18C sect 2;L.6 1 1U 00 psf r,n to nt bott 11 load ppllEd per P.N /TP1 1 0 rlectton 1!24€3 11 e •nd Lf180 or 1 1 ad l `r ITT 1{0508 5X5= 15X4 O. 12 0 0j 7 5 4 1_ 7 6 1 7 E 1? I. 5 4 5 5 5 i 4 5 13 1 10 1 13 5 13 `1 5 5 5 15 0 ._,..1- 15 0 0 -30 0 0 (liar Cu07Urt 1 is 046 PILP4 .IC I r1 COIF 11 1 1P111 0.115 1 0'111 CV.i ABM 1 1 11 11 'S P>`'Y. 4X8kB3) i R 131613 314 W 3 5 0 4 3 .1_ 1 3 0 0 ip,rhe_ e hord i 1. 3 Cl s171t Cri tPl 2013 fIBt.. Tia 20 Gauge HS Wave. C3 /RT =1 00(1 'S) 710(0) 7 2 0411 1 Pret TY L WA/ /Li r l a1 1675 /Ft Lti7dLL MA 452.3366 Sl6 N! I s1 ciao ,a -l1 wIr If, ;14:4 J 61 Late Fam RA, terl aclgr-IedtVA ev 4 tv� yr .a rY1 a q fl. LL Il P. F �_FE �7i1' i9 4$ 'E I'"' "F 44, 11. F s TC [1 i_ 7 0 P 5 F GATE 10/17/040 .4. 4 n p t 1 ft o- tw .a .1L: Apr l0 ,l P S I �n L 11SN 11 76_ J1). .3 ALPINE t r c BC LL lc P5F i C< £ti f, ,uli3fGNH If; Ir, ar M s i.� •-L •1 C n .1sr k. TOT LO "7 1J `5F ,F 141 30 .w IR u. GUP fat 1 15 SPAT—Ty-6— :4 0 J- EI 111 117 04 CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY ECONOMIC DEVELOPMENT BUILDING DIVISION 321 EAST 5TH STREET PORT ANGELES WA 98362 Application Number 09 00000101 Date 2/17/09 Application pin number 104443 Property Address 805 E 2ND ST ASSESSOR PARCEL NUMBER 06 30 00 5 1 2430 0000 Tenant nbr name DONALD /BOBBIE EDGMON Application type description RES DETACHED GARAGE Subdivision Name Property Use Property Zoning RESIDENTIAL HIGH DENSITY Application valuation 27000 Application desc 900 SQ FT DETACHED GARAGE Owner Contractor DONALD /BOBBIE EDGMON OWNER 805 E SECOND ST PORT ANGELES WA 98362 (360) 460 0204 Structure Information 000 000 ADD 900 SF DETACHED GARAGE Other struct info HARD SURFACE AREA Permit BUILDING PERMIT RESIDENTIAL Additional desc ADD 900 SF DETACHED GARAGE Permit pin number 141077 Permit Fee 437 95 Plan Check Fee 284 67 Issue Date 2/17/09 Valuation 27000 Expiration Date 8/16/09 Qty Unit Charge Per Extension BASE FEE 417 75 2 00 10 1000 THOU BL -25 001 50K (10 10 PER K) 20 20 Special Notes and Comments The Fire Department has reviewed the project application and has no comments February 12 2009 4 16 04 PM sroberds Permit is for detached accessory garage in the RHD No land use issues are anticipated MAINTAIN CLEARANCES FROM SERVICE WIRES Electrical load calculations and electrical permits are required Any modifications to the City s electrical facilities will be at the customer s expense Existing sewer lateral may be located under proposed garage Any damage to sewer requires an inspection by Public Works Engineering prior to covering repair Call 417 4831 for inspection Other Fees DOUBLE PERMIT FEE 437 95 STATE SURCHARGE 4 50 Fee summary Charged Paid Credited Due F'0 f Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned fora period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the last inspection I hereby certify that 1 have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. 217Joq >6 f Date Print Name ture of Contractor or Authorized Agent Signature of Owner (if owner is builder) T.FormsBuilding Di Pe FOUNDATION Footings Stemwall Foundation Drainage Downspouts Piers Post Holes (Pole Bldgs.) PLUMBING Under Floor Slab Rough -In Water Line (Meter to Bldg) Gas Line Back Flow Water AIR SEAL. Walls Ceiling FRAMING Joists Girders Under Floor Shear Wall Hold Downs Walls Roof Ceiling Drywall (Interior Braced Panel Only) T -Bar BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDE A MINIMUM 24 -HOUR NOTICE FOR INSPECTIONS Building Inspections 417 4815 Electrical Inspections 417 4735 Public Works Utilities 417 4831 Backflow Prevention Inspections 417 4886 IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED POST PERMIT IN CONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments INSULATION. Slab Wall Floor Ceiling MECHANICAL. Heat Pump Furnace FAU Ducts Rough -In Gas Line Wood Stove Pellet Chimney Commercial Hood Ducts MANUFACTURED HOMES Footing Slab Blocking Hold Downs Skirting PLANNING DEPT Separate Permit #s SEPA. Parking Lighting 1 ESA. Landscaping 1 SHORELINE. Inspection Type Electrical 417 -4735 Construction R.W PW Engineering 417 -4831 Fire 417 -4653 Planning 417 -4750 Building 417 -4815 T:Forms /Building Division /Building Permit FINAL Date Accepted by ANAL Date Accepted by FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/ USE Date Accepted By r'" Application Number Application pin number Permit Fee Total Plan Check Total Other Fee Total Grand Total CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY ECONOMIC DEVELOPMENT BUILDING DIVISION 321 EAST 5TH STREET PORT ANGELES, WA 98362 Page 2 09 00000101 Date 2/17/09 104443 437 95 437 95 00 00 284 67 284 67 00 00 442 45 442 45 00 00 1165 07 1165 07 00 00 Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the last inspection I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Date Print Name Signature of Contractor or Authorized Agent Signature of Owner (if owner is builder) T.Forms/Building Division/Building Permit Inspection Type FOUNDATION Footings Stemwall Foundation Drainage Downspouts Piers Post Holes (Pole Bldgs.) PLUMBING Under Floor Slab Rough -In Water Line (Meter to Bldg) Gas Line Back Flow Water AIR SEAL. Walls Ceiling FRAMING Joists Girders Under Floor Shear Wall Hold Downs Walls Roof Ceiling Drywall (Interior Braced Panel Only) T -Bar INSULATION. Slab Wall Floor Ceiling MECHANICAL. Heat Pump Fumace FAU Ducts Rough -In Gas Line Wood Stove Pellet Chimney Commercial Hood Ducts MANUFACTURED HOMES Footing Slab Blocking Hold Downs Skirting T Forms /Building Division /Building Permit BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDE A MINIMUM 24 -HOUR NOTICE FOR INSPECTIONS Building Inspections 417 4815 Electrical Inspections 417 4735 Public Works Utilities 417 4831 Backflow Prevention Inspections 417 4886 IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED POST PERMIT IN CONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Date Accepted By :3- 2 (0° -b IkL PLANNING DEPT Separate Permit #s SEPA. Parking Lighting 1 ESA. Landscaping 1 SHORELINE. Comments e'er letter dcc 3 -0 q G FINAL Date Accepted by FINAL Date Accepted by FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/ USE Inspection Type Date Accepted By Electrical 417 -4735 Construction R W PW Engineering 417 -4831 Fire 417 -4653 }u— Planning 417 -4750 r Building 417 -4815 5_I 1 a c�L-L— (._Q 1_ Floor Areas Basement 1St Floor 2nd Floor 3 Floor Garage Carport Covered Porch Deck Shed Other Total footprint of structures I/�15 „2.00S Max. height of proposed structures 17 f7 Will a lawn sprinkler system be installed? Will a fire sprinkler system be installed? BUILDING PERMI- YTPPLA TION Print in ink CITY OF PORT ANGELES Attn: Building Permit Technician 321 E. Fifth St. Port Angeles, WA 98362 (360) 417 -4815 fax (360) 4 17 -4711 Applicant or Agent /(,Q //c Property Owner /opt Property Owner's Address 7S Contractor /Engineer 40rp►-e owv► Contractor /Engineer's Address License ft. Cfr_*_tz a_0 Expires *5ap AOP n o U O� ,nU� QS'C� PROJECT ADDRESS r 2' Ft Parcel Number O(-3D OD 57 2 43 D Project Type Brief Description. residential Commercial Check all that apply New Construction Addition Remodel Repair Re -roof Demolition Heat System o Other Existing (sp. ft) Posed (sa. ft.) sq. ft. T Lot size i0C0 Occupancy group Occupant Toad Construction type t Phone Phone one E -mail Lot 1 ho- f-r..0 kp shed 4 Si a.Vk ape i a A 'dui.) a ir) u441 be Rbu re l Heat pump wood- burning stove gas fireplace pellet stove For City UsP only to Received 0 't# Cer, pproved I,S 6 0'204 Zoning f 4t;0 Multi- family Industrial other per sq. ft. 2700D TOTAL VALUATION 2 .7, 0CY) sq. ft. Lotcoverage% a$ G of bedrooms of full baths ,n of half baths a 1 have read and completed this application and know it to be true and correct. 1 am authorized to apply for this permit and understand that it is my responsibility to determine what permits are required, and to obtain permits prior to working on projects. Date J1/2 Print Name Dvl ,g41 Signature S>cfrv.. 14A‘.* z° ao M` trod o gcxs cat, =,,i 1V 471 =L 0 0 '~ .....;;;;0 CITY OF PORT ANGELES PUBLIC WORKS - BUILDING DIVISION 321 EAST 5TH STREET, PORT ANGELES, W A 98362 BUILDING PERMIT OWNER/APPLICANT DON EDGMON 805 E 2ND STREET Port Angeles, WA 98362 360/000-0000 T: S: ISSUED: 1/03/2002 PERMIT NO: 13164 PROPERTY LOCATION 805 2ND ST E Lot: 11 Block: 24 D Long Legal Subdivision: NR SMITH Parcel No: 063000512430000 CONTRACTOR FOXS REMODELING & ROOFING 428 ORCAS PORT ANGELES, WA 00009-8362 360/457-4742 PROJECT INFO Project Value: $3,318.00 Project Type: REROOF Occupancy Type: RESIDENTIAL Occupancy Group: Construction Type: Zoning Use: ARCHITECT NIA , 98360-0000 360/000-0000 SFD Units: SFD SO FT: Commercial: Industrial: Garage: o o o o o ':x:-; ,S V. '\, MFD Units: MFD SO FT: o o \,.,} , , ,.\ ;:: ( ") ..~ PROJECT NOTES TEAROFF 1 FELT 1 COMP RECEIPT # 8688 FEES ASSESSMENT Building Permit: Plan Check: State Surcharge: House Moving: Manufactured Home: Sign: Plumbing: Mechanical: Radon: $97.25 $0.00 $4.50 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Misc Fee 1: Misc Fee 2: Misc Fee 3: $0.00 $0.00 $0.00 TOTAL FEE: AMOUNT PAID: BALANCE DUE: $101.75 $101.75 $0.00 Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work as commenced, or i!required Inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances goveming this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of co~struction. s: ,~ 01 - 0'3 -Joo...... Sig re of Contractor or Authorized Agent Date Signature of Owner (if owner is builder) Date BUILDING PERMIT INSPECTION RECORD CALL 417-4815 FOR BUILDING iNSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLA WFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED COMMENTS VES I NO FOUNDATION: FOOTINGS WALLS FOUNDA liON DRAINAGE ELECTRICAL (LIGHT DEPT) SEPARATE PERMIT: # ROUGH+fN I I I PLUMBING UNDER FLOOR I SLAB ROUGH-IN WATER LINE GAS LINE BACK FLOW I WATER AIR SEAL WALLS I CEILING T FRAMING JOISTS / GIRDERS SHEAR WALL WALLS / ROOF I CEILING DRYWALL T-BAR INSULATION SLAB WALL I FLOOR / CEILING I I MECHANICAL HEAT PUMP WOODSTOVE I PELLET/CHIMNEY I INSERT HooD/DUCTS PW UTILITIES I SITE WORK (Engineering Division) SEPARATE PERMIT #'s: WATERLINE I METER SEWER CONNECTION SANITARY STORM PLANNING DEPT. SEPARATE PERMIT #'s SEPA: PARKING/LIGHTING ESA: LANDSCAPING SHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED YES NO ELECTRICAL - LIGHT DEPT. 417-4735 ELECTRICAL LIGHT DEPT CONSTRUCTION R. W. I PW I CONSTRUCTION - R.W. ENGINEERING 417-4807 PW I ENGINEERING FIRE 417.4653 FIRE DEPT. PLANNING DEPT. 417-4750 / / / )/1 PLANNING DEPT. tJl- , BUILDING BUILDING 417-4815 T 7 C\APPl.WPD