Loading...
HomeMy WebLinkAbout921 W 15th St PermitApplication Number . . . . . 23-00000190 Date 3/15/23 Application pin number . . . 227830 Property Address . . . . . . 921 W 15TH ST ASSESSOR PARCEL NUMBER: 06-30-00-0-4-1470-0000- Application type description ELECTRICAL ONLY Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . RS7 RESDNTL SINGLE FAMILY Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc PV system ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ TERRY, TYLER REVOLUTION ENERGY SYSTEMS INC 921 W 15TH ST 9981 W 190TH ST UNIT K PORT ANGELES WA 98363 MOKENA IL 60448 (801) 406-5250 (509) 993-7858 ---------------------------------------------------------------------------- Permit . . . . . . ELECTRICAL ALTER RESIDENTIAL Additional desc . . 1-4 CIRCUITS Permit Fee . . . . 195.00 Plan Check Fee . . .00 Issue Date . . . . 3/15/23 Valuation . . . . 0 Expiration Date . . 9/11/23 Qty Unit Charge Per Extension BASE FEE 75.00 1.00 120.0000 ECH EL-0-200 SRV FEEDER 120.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 195.00 195.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 195.00 195.00 .00 .00 Public Works and Utilities Department 321 E. 5th Street, Port Angeles, WA 98362 360.417.4735 | www.cityofpa.us | electricalpermits@cityofpa.us EL1-2 SF 1 - 2 SINGLE-FAMILY ELECTRICAL PERMIT APPLICATION Project Address: Project Description: □Single-Family Residential □ Duplex / ARU Building Square footage: OWNER INFORMATION Name: Email: Mailing Address: Phone: ELECTRICAL CONTRACTOR INFORMATION Name: License: Mailing Address: Expiration Date: Email: Phone: PROJECT DETAILS Item Unit Charge Quantity Total (Quantity x Unit Charge) Service/Feeder 200 Amp.$120.00 $ Service/Feeder 201-400 Amp.$146.00 $ Service/Feeder 401-600 Amp.$205.00 $ Service/Feeder 601-1000 Amp.$262.00 $ Service/Feeder over 1000 Amp.$373.00 $ Branch Circuit W/ Service Feeder $5.00 $ Branch Circuit W/O Service Feeder $63.00 $ Each Additional Branch Circuit $5.00 $ Branch Circuits 1-4 $75.00 $ Temp. Service/Feeder 200 Amp.$93.00 $ Temp. Service/Feeder 201-400 Amp.$110.00 $ Temp. Service/Feeder 401-600 Amp.$149.00 $ Temp. Service/Feeder 601-1000 Amp.$168.00 $ Portal to Portal Hourly $96.00 $ Signal Circuit/Limited Energy - 1&2 DU.$64.00 $ Manufactured Home Connection $120.00 $ Renewable Elec. Energy: 5KVA System or less $102.00 $ Thermostat (Note: $5 for each additional)$56.00 $ First 1300 Square Feet $120.00 $ Each Additional 500 square feet``$40.00 $ Each Outbuilding / Detached Garage $74.00 $ Each Swimming Pool / Hot Tub $110.00 $ TOTAL $ Owner as defined by RCW.19.28.261: (1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is required to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection. After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I am making the electrical installation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296- 46B, The City of Port Angeles Municipal Code, and Utility Specifications and PAMC 14.05.050 regarding Electrical Permit Applications. Date Print Name Signature (□Owner □Electrical Contractor / Administrator)Permit #: New Construction Only [Electrical Permit Applications may be submitted to City Hall or epermits@cityofpa.us or faxed to 360.417.4711] PREPARED 2/23/23, 8:17:34 PAYMENT DUE CITY OF PORT ANGELES PROGRAM BP820L --------------------------------------------------------------------------- APPLICATION NUMBER:23-00000190 921 W 15TH ST FEE DESCRIPTION AMOUNT DUE --------------------------------------------------------------------------- ELECTRICAL ALTER RESIDENTIAL 195.00 TOTAL DUE 195.00 Please present reciept to the cashier with full payment 76 North Meadowbrook Drive Scott E. Wyssling, PE Alpine, UT 84004 Coleman D. Larsen, SE, PE office (201) 874-3483 Gregory T. Elvestad, PE swyssling@wysslingconsulting.com December 1, 2022 Revolution Solar 9981 West 190th Street Unit K, Mokena, IL Re: Engineering Services Tyler Residence 921 West 15th Street, Port Angeles, W A 8.450 kW System To Whom It May Concern: We have received information regarding solar panel installation on the roof of the above referenced structure. Our evaluation of the structure is to verify the existing capacity of the roof system and its ability to support the additional loads imposed by the proposed solar system. A. Site Assessment Information 1. Site visit documentation identifying attic information including size and spacing of framing for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information will be utilized for approval and construction of the proposed system. B. Description of Structure: Roof Framing: Prefabricated wood trusses at 24” on center. All truss members are constructed of 2x4 dimensional lumber. Roof Material: Composite Asphalt Shingles Roof Slope: 40 degrees Attic Access: Accessible Foundation: Permanent C. Loading Criteria Used • Dead Load o Existing Roofing and framing = 7 psf o New Solar Panels and Racking = 3 psf o TOTAL = 10 PSF • Dead Load o Existing Roofing and framing = 7 psf o New Solar Panels and Racking = 3 psf o TOTAL = 10 psf • Live Load = 20 psf (reducible) – 0 psf at locations of solar panels • Ground Snow Load = 20 psf • Wind Load based on ASCE 7-16 o Ultimate Wind Speed = 115 mph (based on Risk Category II) o Exposure Category C Analysis performed of the existing roof structure utilizing the above loading criteria is in accordance with the 2018 Washington State Residential Code (2018 IRC), including provisions allowing existing structures to not require strengthening if the new loads do not exceed existing design loads by 105% for gravity elements and 110% for seismic elements. This analysis indicates that the existing framing will support the additional panel loading without damage, if installed correctly. Page 2 of 2 D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent SunModo installation manual. If during solar panel installation, the roof framing members appear unstable or deflect non- uniformly, our office should be notified before proceeding with t he installation. 2. The maximum allowable withdrawal force for a 5/16” lag screw is 235 lbs per inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications. Based on a minimum penetration depth of 2½”, the allowable capacity per connection is greater than the design withdrawal force (demand). Considering the variable factors for the existing roof framing and installation tolerances, the connection using one 5/16” diameter lag screw with a minimum of 2½” embedment will be adequate and will include a sufficient factor of safety. 3. Considering the wind speed, roof slopes, size and spacing of framing members, and condition of the roof, the panel supports shall be placed no greater than 48” on center. 4. Panel supports connections shall be staggered to distribute load to adjacent framing members. Based on the above evaluation, this office certifies that with the racking and mounting specified, the existing roof system will adequately support the additional loading imposed by the solar system. This evaluation is in conformance with the 2018 Washington State Residential Code, current industry standards, and is based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. Very truly yours, Scott E. Wyssling, PE Washington License No. 20111163 Signed 12/01/2022 AERIAL VIEW:MAP VIEW: GENERAL NOTES 1. INSTALLATION OF SOLAR PHOTOVOLTAIC SYSTEM SHALL BE IN ACCORDANCE WITH NEC ARTICLE 690, AND ALL OTHER APPLICABLE NEC CODES WHERE NOTED OR EXISTING 2. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110 3. ALL WIRES, INCLUDING THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE IN ACCORDANCE WITH NEC ARTICLE 250 4. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE; THIS SYSTEM IS UTILITY INTERACTIVE PER UL 1741 AND DOES NOT INCLUDE STORAGE BATTERIES OR OTHER ALTERNATIVE STORAGE SOURCES 5. ALL DC WIRES SHALL BE SIZED ACCORDING TO [NEC 690.8] 6. DC CONDUCTORS SHALL BE WITHIN PROTECTED RACEWAYS IN ACCORDANCE WITH [NEC 690.31] 7. ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL JURISDICTIONAL BUILDING CODE PHOTOVOLTAIC (PV) SYSTEM SPECIFICATIONS APPLICABLE GOVERNING CODES SITE SPECIFICATIONS OCCUPANCY: R-3 ZONING: RESIDENTIAL COVER PAGE - PV01 SITE INFORMATION TERRY MICHAEL TYLER 921 W 15TH ST PORT ANGELES, WA 98363 DC System Size: 11.70 kW DC Lat, 48.11402 Long, 123.46147 (26) CANADIAN SOLAR CS3W-450MS 450 PV Modules Inverter(s) CITY OF PORT ANGELES DRAWN BY: N. GARCIA DATE: 11/30/2022 9981 West 190th St Unit K Mokena IL 60448 T: 708-995-1643 Revolution Energy Systems Inc. (26) ENPHASE IQ8M-72-2-US (240V) AC System Size: 8.45 kW AC / 8.45 kVA 2020 NEC 2018 IRC 2018 IMC 2018 IFGC EQUIPMENT: AC System Size: 8.45 kW AC / 8.45 kVA DC SYSTEM SIZE: 11.70 kW DC (26) CANADIAN SOLAR CS3W-450MS 450 PV Modules (26) ENPHASE IQ8M-72-2-US (240V) Inverters RACKING: NANOMOUNT - 48" O.C. SHEET INDEX: PV01 COVER PAGE PV02 SITE PLAN PV03 ROOF ATTACHMENTS PV04 MOUNTING DETAIL PV05 LINE DIAGRAM PV06 ELECTRICAL CALCS PV07 LABELS PV08 PLACARD PV09 SITE PHOTOS Signed 12/01/2022 D R I V E W A Y PROPERTY LINE ~132'-1''PROPERTY LINE ~132'-1''P R O P E R T Y L I N E ~ 4 8 ' - 1 ' ' P R O P E R T Y L I N E ~ 4 8 ' - 1 ' 'ACMMSPCPVJBACMMSPCPVJBSITE INFORMATION TERRY MICHAEL TYLER 921 W 15TH ST PORT ANGELES, WA 98363 DC System Size: 11.70 kW DC Lat, 48.11402 Long, 123.46147 (26) CANADIAN SOLAR CS3W-450MS 450 PV Modules Inverter(s) CITY OF PORT ANGELES DRAWN BY: N. GARCIA DATE: 11/30/2022 9981 West 190th St Unit K Mokena IL 60448 T: 708-995-1643 Revolution Energy Systems Inc. (26) ENPHASE IQ8M-72-2-US (240V) AC System Size: 8.45 kW AC / 8.45 kVA SITE PLAN - PV02 MOUNTING PLANE: MP1 ARRAY DETAILS: AZIMUTH: 240° TILT: 40° MP2 60°40° VISIBLE, LOCKABLE, LABELED AC DISCONNECT LOCATED WITHIN 10' OF UTILITY METER CLOSE UP OF HOUSE MSP M UTILITY METER PV AC VISIBLE, LOCKABLE, LABELED AC DISCONNECT METER SOCKET (For utility PV meter) INV C INVERTER EQUIPMENT LEGEND: SUB PANEL COMBINER BOX LC BATT SD JB PV MODULES PROPERTY LINE SUB LOAD CENTER BATTERY(IES)JUNCTION BOXMAIN SERVICE PANEL SERVICE DISCONNECT SS SMART SWITCH (IQ System Controller) FIRE ACCESS PATHWAY (3' TYP) ATS AUTOMATIC TRANSFER SWITCH M P 1 GARAGE MAIN HOUSE M P 2 Signed 12/01/2022 ACMMSPCPVJBSITE INFORMATION TERRY MICHAEL TYLER 921 W 15TH ST PORT ANGELES, WA 98363 DC System Size: 11.70 kW DC Lat, 48.11402 Long, 123.46147 (26) CANADIAN SOLAR CS3W-450MS 450 PV Modules Inverter(s) CITY OF PORT ANGELES DRAWN BY: N. GARCIA DATE: 11/30/2022 9981 West 190th St Unit K Mokena IL 60448 T: 708-995-1643 Revolution Energy Systems Inc. (26) ENPHASE IQ8M-72-2-US (240V) AC System Size: 8.45 kW AC / 8.45 kVA ROOF ATTACHMENTS - PV03 PV MODULE COUNT: ARRAY AREA: ROOF AREA: PHOTOVOLTAIC ARRAY STRUCTURAL CRITERIA: 26 PERCENT OF ROOF COVERED: ARRAY WEIGHT: POINT LOAD: DISTRIBUTED LOAD: (lbs/ft²) 992.62 ft² 62% MODULE COUNT * 54.9 lbs = 1427.40 lbs MODULE COUNT * 23.63 ft² = 614.38 ARRAY LBS/ATTACHMENTS = 16.22 (ARRAY)WEIGHT/AREA = 2.3 lbs/ft² HOUSE ELEVATION EQUIPMENT INFORMATION: RAIL MANUFACTURER: RAIL PART NUMBER: ATTACHMENTS ATTACHMENT QTY: SPLICE QTY: MIDCLAMP QTY: ENDCLAMP QTY: SUNMODO SMR NANOMOUNT 88 10 38 20 ROOF TYPE: ROOF FRAMING: RAFTER/TOP CHORD SIZE: RAFTER/TOP CHORD SPACING: ATTACHMENT SPACING: ROOF INFORMATION COMP SHINGLE MANUFACTURED TRUSS 2" X 4" 24" 48" 3'TYP 3'TYP 34'-10" 3' TYP 20'-11" 14'-2" 32'-10" Signed 12/01/2022 SITE INFORMATION TERRY MICHAEL TYLER 921 W 15TH ST PORT ANGELES, WA 98363 DC System Size: 11.70 kW DC Lat, 48.11402 Long, 123.46147 (26) CANADIAN SOLAR CS3W-450MS 450 PV Modules Inverter(s) CITY OF PORT ANGELES DRAWN BY: N. GARCIA DATE: 11/30/2022 9981 West 190th St Unit K Mokena IL 60448 T: 708-995-1643 Revolution Energy Systems Inc. (26) ENPHASE IQ8M-72-2-US (240V) AC System Size: 8.45 kW AC / 8.45 kVA SHARED RAIL END CLAMP SHARED RAIL BONDING MID CLAMP 1 2 PV MODULE RAIL PV MODULE RAIL PV MODULE 1'-8" MAX. RAIL FRONT VIEW 1 END CLAMP DETAILS 2 MID CLAMP DETAILS RAIL NANO MOUNT 10" MIN - 1'-4" MAX 2'-8" MIN - 3'-10" MAX (E) RAFTER/TOP CHORD 2'-8" MIN - 3'-10" MAX 3 10" MIN - 1'-4" MAX (E) RAFTER/TOP CHORDS 48" MAX SPAN 3 DETAIL, MOUNTING AND FLASHING SIDE VIEW 6" MAX MOUNTING DETAIL - PV04 PV MODULE COUNT: ARRAY AREA: ROOF AREA: PHOTOVOLTAIC ARRAY STRUCTURAL CRITERIA: 26 PERCENT OF ROOF COVERED: ARRAY WEIGHT: POINT LOAD: DISTRIBUTED LOAD: (lbs/ft²) 992.62 ft² 62% MODULE COUNT * 54.9 lbs = 1427.40 lbs MODULE COUNT * 23.63 ft² = 614.38 ARRAY LBS/ATTACHMENTS = 16.22 (ARRAY)WEIGHT/AREA = 2.3 lbs/ft² EQUIPMENT INFORMATION: RAIL MANUFACTURER: RAIL PART NUMBER: ATTACHMENTS ATTACHMENT QTY: SPLICE QTY: MIDCLAMP QTY: ENDCLAMP QTY: SUNMODO SMR NANOMOUNT 88 10 38 20 ROOF TYPE: ROOF FRAMING: RAFTER/TOP CHORD SIZE: RAFTER/TOP CHORD SPACING: ATTACHMENT SPACING: ROOF INFORMATION COMP SHINGLE MANUFACTURED TRUSS 2" X 4" 24" 48" Signed 12/01/2022 SITE INFORMATION TERRY MICHAEL TYLER 921 W 15TH ST PORT ANGELES, WA 98363 DC System Size: 11.70 kW DC Lat, 48.11402 Long, 123.46147 (26) CANADIAN SOLAR CS3W-450MS 450 PV Modules Inverter(s) CITY OF PORT ANGELES DRAWN BY: N. GARCIA DATE: 11/30/2022 9981 West 190th St Unit K Mokena IL 60448 T: 708-995-1643 Revolution Energy Systems Inc. (26) ENPHASE IQ8M-72-2-US (240V) AC System Size: 8.45 kW AC / 8.45 kVA LINE DIAGRAM - PV05 TYPE: MODULES: INVERTERS: AC DISCONNECTS: QTY: (26) (1) DESCRIPTION: CANADIAN SOLAR CS3W-450MS 450 PV AC Disconnect, 240V, 2-Pole, with 50A Fuses RATING: 450 W 60 A Equipment Schedule PV AC DISCONNECT 60A VISIBLE, LOCKABLE, LABELED, OPEN 240V, 2-POLE WITH 50A FUSES 1 (2) (1)THWN-2 COPPER - (GROUND)N/A - FREE AIR 2 (2) (1)10 AWG (90°C) THHN/THWN-2, COPPER - (L1, L2) THWN-2 COPPER - (GROUND) 3/4" EMT TAG QTY WIRE GAUGE Conduit & Conductor Schedule DESCRIPTION CONDUIT SIZE CANADIAN SOLAR CS3W-450MS 450 Specs POWER MAX (PMAX): OPEN CIRCUIT VOLTAGE (VOC): MAX POWER-POINT CURRENT (IMP): MAX POWER-POINT VOLTAGE (VMP): SHORT CIRCUIT CURRENT (ISC): SERIES FUSE RATING: 450W 20A 49.1V 10.96A 41.1V 11.6A LINE SIDE TAP USING INSULATION PEIRCING 705.12(A) (E) G (E) UTILITY METER (E) GROUNDING ELECTRODE N (E) LOADS (E) 100A MAIN SERVICE PANEL 120/240 VAC TO UTILITY GRID (E) LOADS CONNECTION AS A LINE/SUPPLY SIDE CONNECTION - NEC 705.12(A) ENPHASE IQ8M-72-2-US (240V)325 W(26) ENPHASE : IQ8M-72-2-US (240V) Specs MAX INPUT VOLTAGE: MAX INPUT CURRENT: NOMINAL DC INPUT VOLTAGE: MAXIMUM OUTPUT POWER: NOM. OUTPUT VOLTAGE: MAX OUTPUT CURRENT: 1-Phase, 60 HZ, UL 1741 Listed 480 V 20 A 400 V 325 W 240 V 1.35 A Q-CABLE , COPPER (L1, L2) 4 COMBINER BOX:(1)ENPHASE COMBINER 4 N GND 2P - 10A ENVOY-IQ MONITOR J-BOX 3 J-BOX 1 2 13 MODULES ===2P - 20A 2P - 20A J-BOX 1 2 STRING (1): 20.0A 13 MODULES === STRING (2): 20.0A 690.12 RAPID SHUTDOWN COMPLIANT (N) 240V/125A PV ENPHASE PV LOAD CENTER, AC COMBINER WITH INTEGRATED MONITORING, NEMA 3R RATED VISIBLE, LOCKABLE, LABELED AC DISCONNECT LOCATED WITHIN 10' OF UTILITY METER 125 A 10 AWG (90°C) 6 AWG (90°C) 10 AWG (90°C) 10 AWG (90°C) 10 AWG (90°C) THHN/THWN-2, COPPER - (L1, L2) THWN-2 COPPER - (GROUND) 3/4" EMT3 (4) (1) THHN/THWN-2, COPPER - (L1, L2, NEUTRAL) THWN-2 COPPER - (GROUND) 3/4" EMT4 8 AWG (90°C) 8 AWG (90°C) (3) (1) THHN/THWN-2, COPPER - (L1, L2, NEUTRAL) THWN-2 COPPER - (GROUND)5 (3) (1) 6 AWG (75°C) 6 AWG (75°C) 3/4" RMC/IMC LOAD SIDE UTILITY PV PRODUCTION METER BASE LINE SIDE 5 5 ELECTRICAL CALCS - PV06 SYSTEM OCPD CALCULATIONS INVERTER MODEL(S): # OF INVERTER(S): MAX OUTPUT CURRENT: (# OF INVERTERS) X (MAX OUTPUT CURRENT) X 125% <= OCPD RATING SITE INFORMATION TERRY MICHAEL TYLER 921 W 15TH ST PORT ANGELES, WA 98363 DC System Size: 11.70 kW DC Lat, 48.11402 Long, 123.46147 (26) CANADIAN SOLAR CS3W-450MS 450 PV Modules Inverter(s) CITY OF PORT ANGELES DRAWN BY: N. GARCIA DATE: 11/30/2022 9981 West 190th St Unit K Mokena IL 60448 T: 708-995-1643 Revolution Energy Systems Inc. (26) ENPHASE IQ8M-72-2-US (240V) AC System Size: 8.45 kW AC / 8.45 kVA PV LOAD CALCULATIONS: SUPPLY SIDE TIE-IN FEEDER WIRE RATING: (FEEDER RATING ÷ 1.25) 100A 80.0000A (FEEDER WIRES ALLOWABLE SOLAR) 80.0000A (AVAILABLE FOR PV) ALLOWABLE SOLAR CALCULATION 26 1.35A ENPHASE IQ8M-72-2-US (240V) (26 X 1.35A X 1.25) = 44.01A <= 50A, OK STRING CALCULATIONS ENPHASE : IQ8M-72-2-US (240V) MAX AC CURRENT MICRO INVERTER(S) IN SERIES: NOMINAL VOLTAGE / RANGE²: MAX AC OUTPUT POWER: ARRAY DC POWER: TOTAL MAX AC CURRENT: 11700W 35.21A STRING #1 13 4225W STRING #2 13 4225W 211V - 264V211V - 264V TAG QTY DESCRIPTION CONDUIT SIZE CONDUCTOR RATING Conduit & Conductor Schedule CONDUCTOR TEMP. RATE AMBIENT TEMP # OF CONDUCTORS DERATE CONDUCTOR RATING W/DERATES CONDUIT FILLTEMP. DERATEWIRE GAUGE 10 AWG 10 AWG 3/4" EMT 40A 90°C 1.04 11.45% THHN/THWN-2, COPPER - (L1, L2) THWN-2 COPPER - (GROUND)25°C 1.0(1) (2) 1 (1) (2) 6 AWG 10 AWG THWN-2 COPPER - (GROUND)N/A - FREE AIR 40A 90°C 25°C 1.04 N/A - FREE AIR 41.6A N/A - FREE AIR 2 10 AWG 10 AWG 3/4" EMT 40A 90°C 1.04 33.28A 19.09% THHN/THWN-2, COPPER - (L1, L2) THWN-2 COPPER - (GROUND)3 25°C 0.8 (4) (1) 41.6A Q-CABLE , COPPER (L1, L2) 22A 22A NUMBER OF CURRENT CARRYING CONDUCTORS 4-6 7-9 10-20 PERCENT OF VALUES .80 .70 .50 GROUNDING & GENERAL NOTES: 1. PV INVERTER IS UNGROUNDED, TRANSFORMER-LESS TYPE. 2. DC GEC AND AC EGC TO BE SPLICED TO EXISTING ELECTRODE 3. ANY EXISTING WIRING INVOLVED WITH PV SYSTEM CONNECTION THAT IS FOUND TO BE INADEQUATE PER CODE SHALL BE CORRECTED PRIOR TO FINAL INSPECTION. 4. JUNCTION BOX QUANTITIES, AND PLACEMENT SUBJECT TO CHANGE IN THE FIELD - JUNCTION BOXES DEPICTED ON ELECTRICAL DIAGRAM REPRESENT WIRE TYPE TRANSITIONS. 5. AC DISCONNECT NOTED IN EQUIPMENT SCHEDULE OPTIONAL IF OTHER AC DISCONNECTING MEANS IS LOCATED WITHIN 10' OF SERVICE DISCONNECT. INTERCONNECTION NOTES: 1. INTERCONNECTION SIZING, LIMITATIONS AND COMPLIANCE DETERMINED IN ACCORDANCE WITH [NEC 705.12], AND [NEC 690.64]. 2. GROUND FAULT PROTECTION IN ACCORDANCE WITH [NEC 215.9], [NEC 230.95] AND [NEC 690.5] 3. ALL EQUIPMENT TO BE RATED FOR BACKFEEDING. 4. PV BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THE BUSBAR RELATIVE TO THE MAIN BREAKER. DISCONNECT NOTES 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING LIVE ARE CONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS) 2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH 90°C 26.7%8 AWG 8 AWG 55A 52.8A THHN/THWN-2, COPPER - (L1, L2, NEUTRAL) THWN-2 COPPER - (GROUND)4 (3) (1) 25°C 1.0 75°C 1.05 THHN/THWN-2, COPPER - (L1, L2, NEUTRAL) THWN-2 COPPER - (GROUND)5 (3) (1) 25°C 1.0 35.49 %6 AWG 6 AWG 65A 68.3A3/4" RMC/IMC 1.043/4" EMT 7 LABELING NOTES: 1. LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. 2. LABELING REQUIREMENTS BASED ON THE 2017 NATIONAL ELECTRIC CODE, OSHA STANDARD 19010.145, ANSI Z535. 3. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 4. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED [NEC 110.21(B)(3)] 5. LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND; REFLECTIVE, AND PERMANENTLY AFFIXED [IFC 605.11.1.1] 5 (ONLY IF PV INTERCONNECTION CONSISTS OF LOAD SIDE BREAKER) 3 5 (ONLY IF PV INTERCONNECTION CONSISTS OF LOAD SIDE BREAKER) 9 1 6 INTEGRATED DC DISCONNECT *ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL REPRESENATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PRESENTED MAY VERY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON THE ELECTRICAL DIAGRAM PAGE. 6 4 LABEL 1 FOR PV DISCONNECTING MEANS WHERE THE LINE AND LOAD TERMINALS MAY BE ENERGIZED IN THE OPEN POSITION. [NEC 690.13(B)] LABEL 2 PLACED ADJACENT TO THE BACK-FED BREAKER FROM THE INVERTER IF TIE IN CONSISTS OF LOAD SIDE CONNECTION TO BUSBAR. [NEC 705.12(B)(2)(3)(b)] TURN RAPID SHUTDOWN SWICH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY LABEL 7 FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [NEC 690.56(C)(1)(A)] LABEL 6 AT DIRECT-CURRENT EXPOSED RACEWAYS, CABLE TRAYS, COVERS AND ENCLOSURES OF JUNCTION BOXES, AND OTHER WIRING METHODS; SPACED AT MAXIMUM 10FT SECTION OR WHERE SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS. [NEC 690.31(G)(3&4)] LABEL 3 PLACED ADJACENT TO THE BACK-FED BREAKER FROM THE INVERTER IF TIE IN CONSISTS OF LOAD SIDE CONNECTION TO BUSBAR. [NEC 705.12(B)(2)(3)(c)] TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN CONDUCTORS OUTSIDE THE ARRAY. CONDUCTORS WITHIN THE ARRAY REMAIN ENERGIZED IN SUNLIGHT ! LABEL 8 FOR PV SYSTEMS THAT ONLY SHUT DOWN CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [NEC 690.56(C)(1)(b)] LABEL 4 EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUSBAR OR CONDUCTOR SUPPLIED FROM MULTIPLE SOURCES SHALL BE MARKED TO INDICATE THE PRESENCE OF ALL SOURCES [NEC 705.12(B)(3)] MAIN SERVICE PANEL LABELING DIAGRAM:1 LABEL 5 AT POINT OF INTERCONNECTION, MARKED AT AC DISCONNECTING MEANS. [NEC 690.54, NEC 690.13 (B)] 3 2 4 EXISTING SUB PANEL (IF WHERE POINT OF INTERCONNECTION IS MADE) 1 2 PV COMBINER SUBPANEL - AC DISCONNECT 1 5 IF USED TO COMBINE PV OUTPUT CIRCUITS 1 3 4 INVERTER (S) LABEL 9 SIGN LOCATED AT RAPID SHUT DOWN DISCONNECT SWITCH [NEC 690.56(C)(3)]. AC JUNCTION BOX OR COMBINER BOX DC ELECTRIC SHOCK HAZARD WARNING TERMINALS ON %OTH LINE AND LOAD SIDES MAY %E ENERGIZED IN THE OPEN POSITION ! WARNING THIS E4UIPMENT IS FED %Y MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES E;CLUDING MAIN SUPPLY OVERCURRENT DEVICE SHALL NOT E;CEED AMPACITY OF %US%AR. ! INVERTER OUTPUT CONNECTION WARNING DO NOT RECOLCATE THIS OVERCURRENT DEVICE ! DUAL POWER SUPPLY WARNING SOURCES UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM ! RATED AC OUTPUT CURRENT NOMINAL OPERATING AC VOLTAGE PHOTOVOLTAIC AC DISCONNECT 240 V 8 WARNING PHOTOVOLTAIC POWER SOURCE SOLAR PV SYSTEM E4UIPPED WITH RAPID SHUTDOWN SOLAR PV SYSTEM E4UIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS SOLAR ELECTRIC PV PANELS RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM SITE INFORMATION TERRY MICHAEL TYLER 921 W 15TH ST PORT ANGELES, WA 98363 DC System Size: 11.70 kW DC Lat, 48.11402 Long, 123.46147 (26) CANADIAN SOLAR CS3W-450MS 450 PV Modules Inverter(s) CITY OF PORT ANGELES DRAWN BY: N. GARCIA DATE: 11/30/2022 9981 West 190th St Unit K Mokena IL 60448 T: 708-995-1643 Revolution Energy Systems Inc. (26) ENPHASE IQ8M-72-2-US (240V) AC System Size: 8.45 kW AC / 8.45 kVA LABELS - PV07 35.21 A ACMMSPCPVJBSITE INFORMATION TERRY MICHAEL TYLER 921 W 15TH ST PORT ANGELES, WA 98363 DC System Size: 11.70 kW DC Lat, 48.11402 Long, 123.46147 (26) CANADIAN SOLAR CS3W-450MS 450 PV Modules Inverter(s) CITY OF PORT ANGELES DRAWN BY: N. GARCIA DATE: 11/30/2022 9981 West 190th St Unit K Mokena IL 60448 T: 708-995-1643 Revolution Energy Systems Inc. (26) ENPHASE IQ8M-72-2-US (240V) AC System Size: 8.45 kW AC / 8.45 kVA CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED SOLAR ARRAYS WITH SAFETY DISCONNECTS AS SHOWN: 921 W 15TH ST, PORT ANGELES, WA 98363 DIRECTORY PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM. (ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS OUTLINED WITHIN: NEC 690.56(B)&(C), [NEC 705.10]) PLACARD - PV08 AC DISCONNECT MAIN DISTRIBUTION UTILITY DISCONNECT UTILITY METER COMBINER BOX PV ARRAY PV METER SITE INFORMATION TERRY MICHAEL TYLER 921 W 15TH ST PORT ANGELES, WA 98363 DC System Size: 11.70 kW DC Lat, 48.11402 Long, 123.46147 (26) CANADIAN SOLAR CS3W-450MS 450 PV Modules Inverter(s) CITY OF PORT ANGELES DRAWN BY: N. GARCIA DATE: 11/30/2022 9981 West 190th St Unit K Mokena IL 60448 T: 708-995-1643 Revolution Energy Systems Inc. (26) ENPHASE IQ8M-72-2-US (240V) AC System Size: 8.45 kW AC / 8.45 kVA SITE PHOTOS - PV09 SITE PHOTOS: ELECTRICAL INSPECTION WIRING REPORT APPROVED NOT APPROVED DITCH ROUGH IN/COVER SERVICE FINAL COMMENTS NOTIFY INSPECTOR at (360) 808-2613 WHEN CORRECTIONS ARE COMPLETED WITHIN 15 DAYS DATE PERMIT # INSPECTOR 4/5/2023 23-190 TAP OWNER CONTRACTOR Revolution Solar PROJECT ADDRESS 921 W 15th St