Loading...
HomeMy WebLinkAbout1430 Rook Dr - BuildingApplication Number . . . . . 23-00000956 Date 9/07/23 Application pin number . . . 767704 Property Address . . . . . . 1430 ROOK DR ASSESSOR PARCEL NUMBER: 06-30-14-7-2-0240-0000- Application type description ELECTRICAL ONLY Subdivision Name . . . . . . Property Use . . . . . . . . RESIDENTAL SF 9000 Property Zoning . . . . . . . RS9 RESDNTL SINGLE FAMILY Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc PV system ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ CAROL C AND KENNETH B KIDDER POWER TRIP ENERGY CORP. 1430 ROOK DR 83 DENNY AVE PORT ANGELES WA 98362 PORT TOWNSEND WA 98368 (612) 718-9725 (360) 643-3080 ---------------------------------------------------------------------------- Permit . . . . . . ELECTRICAL ALTER RESIDENTIAL Additional desc . . Permit Fee . . . . 240.00 Plan Check Fee . . .00 Issue Date . . . . 9/07/23 Valuation . . . . 0 Expiration Date . . 3/05/24 Qty Unit Charge Per Extension 2.00 120.0000 ECH EL-0-200 SRV FEEDER 240.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 240.00 240.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 240.00 240.00 .00 .00 Public Works and Utilities Department 321 E. 5th Street, Port Angeles, WA 98362 360.417.4735 | www.cityofpa.us | electricalpermits@cityofpa.us EL1-2 SF 1 - 2 SINGLE-FAMILY ELECTRICAL PERMIT APPLICATION Project Address: Project Description: □Single-Family Residential □ Duplex / ARU Building Square footage: OWNER INFORMATION Name: Email: Mailing Address: Phone: ELECTRICAL CONTRACTOR INFORMATION Name: License: Mailing Address: Expiration Date: Email: Phone: PROJECT DETAILS Item Unit Charge Quantity Total (Quantity x Unit Charge) Service/Feeder 200 Amp.$120.00 Service/Feeder 201-400 Amp.$146.00 $ Service/Feeder 401-600 Amp.$205.00 $ Service/Feeder 601-1000 Amp.$262.00 $ Service/Feeder over 1000 Amp.$373.00 $ Branch Circuit W/ Service Feeder $5.00 $ Branch Circuit W/O Service Feeder $63.00 $ Each Additional Branch Circuit $5.00 $ Branch Circuits 1-4 $75.00 $ Temp. Service/Feeder 200 Amp.$93.00 $ Temp. Service/Feeder 201-400 Amp.$110.00 $ Temp. Service/Feeder 401-600 Amp.$149.00 $ Temp. Service/Feeder 601-1000 Amp.$168.00 $ Portal to Portal Hourly $96.00 $ Signal Circuit/Limited Energy - 1&2 DU.$64.00 $ Manufactured Home Connection $120.00 $ Renewable Elec. Energy: 5KVA System or less $102.00 $ Thermostat (Note: $5 for each additional)$56.00 $ First 1300 Square Feet $120.00 $ Each Additional 500 square feet``$40.00 $ Each Outbuilding / Detached Garage $74.00 $ Each Swimming Pool / Hot Tub $110.00 $ TOTAL $ Owner as defined by RCW.19.28.261: (1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is required to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection. After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I am making the electrical installation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296- 46B, The City of Port Angeles Municipal Code, and Utility Specifications and PAMC 14.05.050 regarding Electrical Permit Applications. Date Print Name Signature (□Owner □Electrical Contractor / Administrator)Permit #: New Construction Only [Electrical Permit Applications may be submitted to City Hall or electricalpermits@cityofpa.us or faxed to 360.417.4711] 1430 Rook Dr Port Angeles, WA 98362 14.36 kW Grid-Tied Roof-Mounted PV Carol & Kenneth Kidder ken.b.kidder@gmail.com 1430 Rook Dr Port Angeles, WA 98362 (612) 718-9725 Power Trip Energy POWERTE964JN 4-15-202483 Denny Ave Port Townsend, WA 98368 buddy@powertripenergy.com (360) 643-3080 $ 8/31/2023 Andy Cochrane 240.00 2 240.00 AC PC SYSTEM STATS PV MODULE Make and model – 435-AC INVERTER Make and model – Enphase IQ7HS 384W Max AC amps – 1.6A (continuous) AC volts – 240V AC watts –384W SYSTEM # of branch circuits –4 # of inverters in branch circuit – 10,10,10,3 Branch circuit operating amps – 16A, 16A, 16A, 4.8A System operating amps – 52.8A (continuous) System operating volts – 240V Sizing Conductors and Overcurrent Devices (690.8(B)(1) Circuit Breaker - (operating amps x 1.25 = 20A (20A breaker) Branch Circuit - #12 THHN minimum System breaker – continuous output of all inverters x 1.25 = 66A, 70A breaker Equipment Grounding Conductor - #12 minimum This PV system includes AC PV modules. The inverter is built into the module. SunPower® Maxeon® Technology Built specifically for use with the SunPower Equinox® system, the only fully integrated solar solution designed, engineered, and warranted by one company. Highest Power AC Density Available. The patented, solid-copper foundation Maxeon Gen 6 cell is over 5% larger than prior generations, delivering the highest efficiency AC solar panel available.1 Highest Lifetime Energy and Savings Designed to deliver 60% more energy over 25 years in real-world conditions like partial shade and high temperatures.2 Best Reliability, Best Warranty With more than 42.6 million and 15 GW modules deployed around the world, SunPower technology is proven to last. That’s why we stand behind our module and microinverter with the industry’s best 25-year Combined Power and Product Warranty. Datasheet 0510 15 20 25 150% 140% 130% 120% 110% 100% 90% 80% 70% 60%25-year Energy Yield per WattYears of Operation Up to 60% More Lifetime Energy Conventional Panel M-Series Part of the SunPower Equinox® Solar System • Compatible with mySunPowerTM monitoring • Seamless aesthetics Factory-integrated Microinverter • Highest-power integrated AC module in solar • Engineered and calibrated by SunPower for SunPower AC modules 6.37 in[161.7 mm]6.54 in[166 mm]5% larger 420-440W Residential AC Module M-Series: M440 | M435 | M430 | M425 | M420 SunPower® Residential AC Module 1 Based on datasheet review of websites of top 20 manufacturers per Wood Mackenzie US PV Leaderboard Q3 2021. 2 Maxeon 435 W, 22.5% efficient, compared to a Conventional Panel on same-sized arrays (260 W, 16% efficient, approx. 1.6 m²), 7.9% more energy per watt (based on PVSyst pan files for avg. US climate), 0.5%/yr slower degradation rate (Jordan, et. al. “Robust PV Degradation Methodology and Application.”PVSC 2018). 3 Voltage range can be extended beyond nominal if required by the utility. 4 Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. 5 Factory set to IEEE 1547a-2014 default settings. CA Rule 21 default settings profile set during commissioning. 6 Standard Test Conditions (1000 W/m² irradiance, AM 1.5, 25°C). All DC voltage is fully contained within the module. 7 UL Listed as PVRSE and conforms with NEC 2014 and NEC 2017 690.12; and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors; when installed according to manufacturer’s instructions. 8 Please read the safety and installation instructions for more information regarding load ratings and mounting configurations. See www.sunpower.com/company for more reference information. Specifications included in this datasheet are subject to change without notice. ©2022 SunPower Corporation. All rights reserved. SUNPOWER, the SUNPOWER logo, EQUINOX and MYSUNPOWER are trademarks or registered trademarks of SunPower Corporation in the U.S. MAXEON is a registered trademark of Maxeon Solar Technologies, Ltd. For more information visit www.maxeon.com/legal. AC Electrical Data Inverter Model: Type H (Enphase IQ7HS)@240 VAC @208 VAC Max. Continuous Output Power (VA)384 369 Nom. (L–L) Voltage/Range3 (V)240 / 211–264 208 / 183–229 Max. Continuous Output Current (Arms)1.60 1.77 Max. Units per 20 A (L–L) Branch Circuit4 10 9 CEC Weighted Efficiency 97.0%96.5% Nom. Frequency 60 Hz Extended Frequency Range 47–68 Hz AC Short Circuit Fault Current Over 3 Cycles 4.82 A rms Overvoltage Class AC Port III AC Port Backfeed Current 18 mA Power Factor Setting 1.0 Power Factor (adjustable)0.85 (inductive) / 0.85 (capacitive) DC Power Data SPR-M440- H-AC SPR-M435- H-AC SPR-M430- H-AC SPR-M425- H-AC SPR-M420- H-AC Nom. Power6 (Pnom) W 440 435 430 425 420 Power Tolerance +5/−0% Module Efficiency 22.8%22.5%22.3%22.0%21.7% Temp. Coef. (Power)−0.29% / °C Shade Tolerance Integrated module-level max. power point tracking Tested Operating Conditions Operating Temp.-40° F to +185°F (-40°C to +85°C) Max. Ambient Temp.122°F (50°C) Max. Test Load8 Wind: 125 psf, 6000 Pa, 611 kg/m² back Snow: 187 psf, 9000 Pa, 917 kg/m² front Max. Design Load Wind: 75 psf, 3600 Pa, 367 kg/m² back Snow: 125 psf, 6000 Pa, 611 kg/m² front Impact Resistance 1 inch (25 mm) diameter hail at 52 mph (23 m/s) Mechanical Data Solar Cells 66 Maxeon Gen 6 Front Glass High-transmission tempered glass with anti-reflective coating Environmental Rating Outdoor rated Frame Class 1 black anodized (highest AAMA rating) Weight 48 lb (21.8 kg) Recommended Max. Module Spacing 1.3 in. (33 mm) Warranties, Certifications, and Compliance Warranties • 25-year limited power warranty • 25-year limited product warranty Certifications and Compliance • UL 1741 / IEEE-1547 • UL 1741 AC Module (Type 2 fire rated) • UL 61730 • UL 62109-1 / IEC 62109-2 • FCC Part 15 Class B • ICES-0003 Class B • CAN/CSA-C22.2 NO. 107.1-01 • CA Rule 21 (UL 1741 SA)5 (includes Volt/Var and Reactive Power Priority) • UL Listed PV Rapid Shutdown Equipment7 Enables installation in accordance with: • NEC 690.6 (AC module) • NEC 690.12 Rapid Shutdown (inside and outside the array) • NEC 690.15 AC Connectors, 690.33(A)–(E)(1) When used with AC module Q Cables and accessories (UL 6703 and UL 2238)7: • Rated for load break disconnect PID Test 1000 V: IEC 62804 Packaging Configuration Modules per pallet 25 Packaging box dimensions 75.4 × 42.2 × 48.0 in. (1915 × 1072 × 1220 mm) Pallet gross weight 1300.7 lb (590 kg) Pallets per container 32 Net weight per container 41,623 lb (18,880 kg) 1-800-SUNPOWER | sunpower.com 539973 RevB January 2022 Please read the safety and installation instructions for details. Solar Agent: Rodney Just Client Name: Kidder Residence August 8, 2023 - 3 - Power Trip Energy Corp 83 Denny Ave, Port Townsend, WA 98368 (360)643-3080 www.powertripenergy.com LIC: POWERTE964JN Project: Kidder Residence Client: Kenneth Kidder Phone: (612) 718-9725 Address: 1430 Rook Drive, Port Angeles, WA 98362 System Description: 14.36 Residential Grid-tied PV AC Circuit Combiner Panel: West Interior Wall on Garage Solar Modules: Branch Circuit A-10 Modules Model: SPR-M435-WHT-AC Micro inverter max power output 384 watts East and West Roofs of Home Net Meter: Remote 25' North of Home Meter #: E52781 Utility Grid: City Of Port Angeles AC System Disconnect: (For Rapid Shutdown of AC Modules) West Exterior Wall on Garage Main Service Panel (LOAD): East Interior Wall in Garage Solar Modules: Branch Circuit B-10 Modules Model: SPR-M435-WHT-AC Micro inverter max power output 384 watts East and West Roofs of Home Solar Modules: Branch Circuit C- 10 Modules Model: SPR-M435-WHT-AC Micro inverter max power output 384 watts East and West Roofs of Home Solar Modules: Branch Circuit D- 3 Modules Model: SPR-M435-WHT-AC Micro inverter max power output 384 watts East and West Roofs of Home Solar Agent: Rodney Just Client Name: Kidder Residence August 8, 2023 - 4 - Power Trip Energy Corp 83 Denny Ave Port Townsend, WA 98368 (360)643-3080 www.powertripenergy.com LIC: POWERTE964JN Project: Kidder Residence Client: Kenneth Kidder Phone: (612) 718-9725 Address: 1430 Rook Drive, Port Angeles, WA 98362 System Description: 14.36 Residential Grid-tied PV Project Photos and Notes: East and West Roofs on Home – Location of 33 SunPower 435 Watt Modules Solar Agent: Rodney Just Client Name: Kidder Residence August 8, 2023 - 5 - West Exterior Wall on Garage – Location of AC Disconnect West Interior Wall In Garage – Location of Combiner Panel & Data Monitoring East Wall in Garage – Location of Electrical Panel Remote, 25’ North of Home – Location of Utility Meter Solar Agent: Rodney Just Client Name: Kidder Residence August 8, 2023 - 6 - East Interior of Garage – Location of Electrical Panel Solar Agent: Rodney Just Client Name: Kidder Residence August 8, 2023 - 7 - Solar Agent: Rodney Just Client Name: Kidder Residence August 8, 2023 - 8 - Exterior Wall on Garage – Location of AC Disconnect Roof on Home – Location of 33 SunPower 435-Watt Modules Remote 25’ North of Home – Location of Utility Meter Interior Wall in Garage – Location Of Electrial Panel, Combiner Panel and Data Monitoring ELECTRICAL INSPECTION WIRING REPORT APPROVED NOT APPROVED DITCH ROUGH IN/COVER SERVICE FINAL COMMENTS NOTIFY INSPECTOR at (360) 808-2613 WHEN CORRECTIONS ARE COMPLETED WITHIN 15 DAYS DATE PERMIT # INSPECTOR 9/20/2023 23-956 TAP OWNER CONTRACTOR Power Trip Energy PROJECT ADDRESS 1430 Rook Dr