Loading...
HomeMy WebLinkAbout532 W 4th St - Building ELECTRICAL PERMIT CITY OF PORT ANGELES O 360 417 -4735 0 Application Number 12- 00000218 Date 3/28/12 c Application pin number 338664 Property Address 532 W 4TH ST REPORT SALES TAX ASSESSOR PARCEL NUMBER: 06-30-00-0-0:8430-0000- on your excise tax form Application type description ELECTRICAL ONLY Subdivision Name to the City of Port Angeles Property Use (Location Code 0502) Property Zoning RS7 RESDNTL SINGLE FAMILY Application valuation 0 Application desc 1 -4 circuits repair Owner Contractor GLOOR JOAN L ANGELES ELECTRIC �J 826 BLACK DIAMOND RD 524 E. 1ST ST. PORT ANGELES WA 983639496 PORT ANGELES WA 98362 (360) 452- 9264 Permit ELECTRICAL ALTER RESIDENTIAL �J Additional desc 1 -4 CIRCUITS Permit Fee 75.00 Plan Check Fee .00 Issue Date 2/29/12 Valuation 0 Expiration Date 9/18/12 Qty Unit Charge Per Extension BASE FEE 75.00 Fee summary Charged Paid Credited Due Permit Fee Total 75.00 75.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 75.00 75.00 .00 .00 INSPECTION TYPE DATE: RESULTS: INSPECTOR: DITCH SERVICE ROUGH -IN 4111.1 l FINAL 9'6gt Z COMMENTS: PERMIT WILL EXPIRE SIX (6) MONTHS FROM LAST INSPECTION Signature of owner or Electrical Contractor X r Date: G: \EXCHANGE \BUILDING oFPORT4'�F ELECTRICAL INSPECTION WIRING REPORT co m `'ewoe s�"F C 417 -4735 DATE: PERMIT INSPECTOR 512.7 --Z-' 17.--2« OWNER CONTRACTOR ADDRESS APPROVED NOT APPROVED DITCH ROUGH IN /COVER SERVICE FINAL CORRECTIONS NEEDED: _52-N.:P P.\ CZ V IAY'11 W LZE_S 1 k.-,1 r-1 P5 L Gw s �"1" ►4V 1 t V1- t ,.i S`S"AL.L. DtD 1 'IrLL- 7 -AriS N1mt, V,1 zA t— tbrc -ce P-, 7't Iz b \rTL 'r gyp F 1 F% 1. c- 1 Ca.o .is1 V NOTIFY INSPECTOR WHEN CORRECTIONS ARE COMPLETED WITHIN 15 DAYS DO NOT REMOVE 02/28/2012 08:41 FAX 360 452 9265 Angeles Electric U0001/0001 p t 1 n Of tT 'e) CITY OF PORT ANGELES PERMIT APPLICATION EL;:0 Building Division/Electrical Inspections INSPECTIOit3 321 East Fifth Street P.O. Box 1150 Port Angeles Washington, 98362 1.0,mpr Ph: (360) 417 -4735 Fax: (360) 417 -4711 cP Date: 2 2 _i_ 1 2 Ingle Fa mily Dwelling Plan Review May Be Required, Please Complete Electrical Plan Review Information Sheet Job Address: S3Z Building Square Footage: LD O Description of above r ebtau t r to ii21lVt 45814S Owner Informatjgji 2 Contractor Information Name: ::11 Name: A ..E4 t.f o—TRICs 2iy Mailing Address: a Mailing ..ress: 4'42 City: State: k4- Zip: 3 City: of 1 14 r' e: _e_4- _,:zip: 3_6 Phon Fax: Phone: Fax: 'fad License Exp. License Exp. Item Unit Charge (3ty Total (Qty Multiplied by Unit Charge) Service/Feeder 200 Amp. 120.00 Service/Feeder 201 -400 Amp. 146.00 Service/Feeder 401 -600 Amp 205.00 Service/Feeder 601 -1000 Amp. 262.00 Service /Feeder over 1000 Amp. 373.00 Branch Circuits 1-4 75.00 75 Branch Circuit WI Service Feeder 5.00 Branch Circuit W/O Service Feeder 63.00 Each Additional Branch Circuit 5.00 Temp. Service/ Feeder 200 Amp. 93.00 Temp. Servioe /Feeder 201 -400 Amp. 110.00 Temp. Service/Feeder 401-600 Amp. 149.00 Temp. Service/Feeder 601 -1000 Amp 168.00 Portal to Porat Hourly 96.00 Signal Circuit/ Limited Energy -18 2 Family Dwelling 64.00 Manufactured Home Connection 120.00 Renewable Electrical Energy 5KVA System or Less 102.00 Thermostat 56.00 NEW CONSTRUCTION ONLY: First 1300 Square Ft. 120.00 Each Additional 500 Square Ft. or Portion of 40.00 Each Outbuilding or Detached Garage 74.00 Each Swimming Pool or Hot Tub 110.00 5 Z Total Owner as defined by RCW.19.28.261: (1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is required to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection. After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I am making the electrical installation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296-46B, The City of Port Angeles Municipal Code, and Utility Specifications and PAMC.14.05.050 regarding Electrical Pemrit Applications. Signature of owner, electrical contractor or electrical administrator: cash Chock Cron and fit/ ICAO x 41�� F`? Dated: 4/21//2-- imam '7 v /fi F I t yy6-r --o gtfca, Electrical Survey For City of Port Angeles Weatherization Program Homeowner: ,m.i AJ (r.. �1.�t �t%t nab D A �a '3 Address: 6 i`; a ;t iV4- v`r: 1 ';al1 is L' E.i; °i' Insulation Installer: Electrical Contractor: ?L :;"fie' i -E` We have surveyed the wiring at the above location and have found the following in regards to the requirements of WAC 296 -46B -394 (see below): Attics: Yes No Active knob tube wiring (T) Junction boxes covered (X) Flying Splices 15 A S fuses or breakers on knob tube circuits X 00 Wiring in good condition r Wiring and circuit protection adequate to meet the load Electrical Work Performed: 4' 4' 3u4Afr it:/ y 4,,, I+rd 'V 64.1k I C �,:a, .`ii „Sr4ttL Notes: Walls: Yes No 15 A S fuses or breakers on knob tube circuits ('r.) (A) Wiring in good condition (c) Wiring and circuit protection adequate to meet the load Electrical Work Performed: Notes: 001 Knob and -tube wiring. Article 394 NEC does not prohibit the installation of loose or rolled thermal insulating material in spaces containing existing knob- and -tube wiring provided that all the following conditions are met: (1) The wiring must be surveyed by an appropriately licensed electrical contractor who must certify in writing to the department that the wiring is in good condition with no evidence of improper overcurrent protection, conductor insulation failure or deterioration, and with no improper connections or splices. The electrical inspector must inspect all repairs, alterations, or extensions to the electrical system. (2) The insulation must meet Class 1 specifications as identified in the Uniform Building Code, with a flame spread factor of twenty -five or less as tested using ASTM E84 -81 a. Foam insulation may not be used with knob -and -tube wiring. (3) All knob and -tube circuits must have overcurrent protection in compliance with NEC Table 310.16, 60 degree centigrade, Column C. Overcurrent protection must be either circuit breakers or Type S fuses. p ORTgyC� ELECTRICAL INSPECTION 9 WIRING REPORT ORKS 417 -4735 DATE PERMIT INSPECTOR 2-'2:1 I 1 Z &A, i trz Fr-S .3 1i 4 )P OWNER /CONTRACTOR ADDRESS X32-- ‘1 APPROVED OT APPROVED DITCH ROUGH IN /COVER SERVICE FINAL 0 CORRECTIONS NEEDED: Gj 9�J7 6L� T IVk 1.1,C G>kkpoc TD iz-S 3i- P- L 13,s- r ki Uc�Ti 2.) ol5 11)16v... lizo 144 gt)rLV w__Yct) g) uG NS p E.LeG` cp c� TQ fl t;T i) fz_ Z L g615 3" 3� C6v-\-Ni vZt1Z1 h s��i' S) -t' Zt_ 1 i19 YF-- 1 °ro Chi 4t 6 Grr 6- 5eVZ -PiT N,-G 110 NOTIFY INSPECTOR WHEN CORRECTIONS ARE COMPLETED WITHIN 15 DAYS DO NOT REMOVE OLYMPIC PRINTERS, INC. (360) 452 -1381 BUILDING PLANNING SECTION R312 Exception: An automatic residential fire sprinkler system GUARDS shall not be required for additions or alterations to existing R312.1 Where required. Guards shall be located along buildings that are not already provided with an automatic open -sided walking surfaces, including stairs, ramps and land residential sprinkler system. ings, that are located more than 30 inches (762 mm) measured R313.2.1 Design and installation. Automatic residential vertically to the floor or grade below at any point within 36 fire sprinkler systems shall be designed and installed in inches (914 mm) horizontally to the edge of the open side. accordance with Section P2904 or NFPA 13D. Insect screening shall not be considered as a guard. R312.2 Height. Required guards at open -sided walking sur SECTION R314 faces, including stairs, porches, balconies or landings, shall be SMOKE ALARMS not less than 36 inches (914 mm) high measured vertically above the adjacent walking surface, adjacent fixed seating or R314.1 Smoke detection and notification. All smoke alarms the line connecting the leading edges of the treads. shall be listed in accordance with UL 217 and installed in accordance with the provisions of this code and the household Exceptions: fire warning equipment provisions of NFPA 72. 1. Guards on the open sides of stairs shall have a height R314.2 Smoke detection systems. Household fire alarm sys- not less than 34 inches (864 mm) measured vertically tems installed in accordance with NFPA 72 that include smoke from a line connecting the leading edges of the treads. alarms, or a combination of smoke detector and audible notifi- 2. Where the top of the guard also serves as a handrail on cation device installed as required by this section for smoke the open sides of stairs, the top of the guard shall not alarms, shall be permitted. The household fire alarm system be not less than 34 inches (864 mm) and not more than shall provide the same level of smoke detection and alarm as 38 inches (965 mm) measured vertically from a line required by this section for smoke alarms. Where a household connecting the leading edges of the treads. fire warning system is installed using a combination of smoke R312.3 Opening limitations. Required guards shall not have detector and audible notification device(s), it shall become a openings from the walking surface to the required guard height permanent fixture of the occupancy and owned by the home which allow passage of a sphere 4 inches (102 mm) in diameter. owner. The system shall be monitored by an approved super vising station and be maintained in accordance with NFPA 72. Exceptions: Exception: Where smoke alarms are provided meeting the 1. The triangular openings at the open side of a stair, requirements of Section R314.4. formed by the riser, tread and bottom rail of a guard, R314.3 Location. Smoke alarms shall be installed in the fol- shall not allow passage of a sphere 6 inches (153 mm) lowing locations: in diameter. 1. In each sleeping room. 2. Guards on the open sides of stairs shall not have open- ings which allow passage of a sphere 4 inches (111 2. Outside each separate sleeping area in the immediate mm) in diameter. vicinity of the bedrooms. R312.4 Exterior woodplastic composite guards. Woodplas 3. On each additional storyof the dwelling, including base tic composite guards shall comply with the provisions of Sec- menu and habitable attics but not including crawl spaces tion R317.4. and uninhabitable attics. In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels, a smoke alarm installed on SECTION R313 the upper level shall suffice for the adjacent lower level AUTOMATIC FIRE SPRINKLER SYSTEMS provided that the lower level is less than one full story below the upper level. R313.1 Townhouse automatic fire sprinkler systems. An When more than one smoke alarm is required to be installed automatic residential fire sprinkler system shall be installed in within an individual dwelling unit the alarm devices shall be townhouses. interconnected in such a manner that the actuation of one alarm Exception: An automatic residential fire sprinkler system will activate all of the alarms in the individual unit. shall not be required when additions or alterations are made R314.3.1 Alterations, repairs and additions. When alter to existing townhouses that do not have an automatic resi- ations, repairs or additions requiring a permit occur, or dential fire sprinkler system installed. when one or more sleeping rooms are added or created in R313.1.1 Design and installation. Automatic residential existing dwellings, the individual dwelling unit shall be fire sprinkler systems for townhouses shall be designed and equipped with smoke alarms located as required for new installed in accordance with Section P2904. dwellings. R313.2 One- and two family dwellings automatic fire sys Exceptions: tems. Effective January 1, 2011, an automatic residential fire 1. Work involving the exterior surfaces of dwellings, sprinkler system shall be installed in one- and two- family such as the replacement of roofing or siding, or the dwellings. addition or replacement of windows or doors, or 62 2009 INTERNATIONAL RESIDENTIAL CODE® BUILDING PLANNING the addition of a porch or deck, are exempt from R316.3 Surface burning characteristics. Unless otherwise the requirements of this section. allowed in Section R316.5 or R316.6, all foam plastic or foam 2. Installation, alteration or repairs of plumbing or plastic cores used as a component in manufactured assemblies mechanical systems are exempt from the require- used in building construction shall have a flame spread index of ments of this section. not more than 75 and shall have a smoke developed index of not more than 450 when tested in the maximum thickness R314.4 Power source. Smoke alarms shall receive their pri- intended for use in accordance with ASTM E 84 or UL 723. mary power from the building wiring when such wiring is Loose -fill type foam plastic insulation shall be tested as board served from a commercial source, and when primary power is stock for the flame spread index and smoke developed index. interrupted, shall receive power from a battery. Wiring shall be permanent and without a disconnecting switch other than those Exception: Foam plastic insulation more than 4 inches (102 required for overcurrent protection. Smoke alarms shall be mm) thick shall have a maximum flame spread index of 75 interconnected. and a smoke developed index of 450 where tested at a mini- mum thickness of 4 inches (102 mm), provided the end use Exceptions: is approved in accordance with Section R316.6 using the 1. Smoke alarms shall be permitted to be battery oper- thickness and density intended for use. ated when installed in buildings without commercial power. R316.4 Thermal barrier. Unless otherwise allowed in Section R316.5 or Section R316.6, foam plastic shall be separated from 2. Interconnection and hard wiring of smoke alarms in the interior of a building by an approved thermal barrier of min existing areas shall not be required where the alter- imum' inch (12.7 mm) gypsum wallboard or an approvedfin- ations or repairs do not result in the removal of inte- ish material equivalent to a thermal barrier material that will rior wall or ceiling finishes exposing the structure, limit the average temperature rise of the unexposed surface to unless there is an attic, crawl space or basement avail- no more than 250 °F (139 °C) after 15 minutes of fire exposure able which could provide access for hard wiring and complying with the ASTM E 119 or UL 263 standard time tem- interconnection without the removal of interior fin- perature curve. The thermal barrier shall be installed in such a ishes. manner that it will remain in place for 15 minutes based on NFPA 286 with the acceptance criteria of Section R302.9.4, FM 4880, UL 1040 or UL 1715. SECTION R315 CARBON MONOXIDE ALARMS R316.5 Specific requirements. The following requirements R315.1 Carbon monoxide alarms. For new construction, an shall apply to these uses of foam plastic unless specifically approved carbon monoxide alarm shall be installed outside of approved in accordance with Section R316.6 or by other sec each separate sleeping area in the immediate vicinity of the tions of the code or the requirements of Sections R316.2 bedrooms in dwelling units within which fuel -fired appliances through R316.4 have been met. are installed and in dwelling units that have attached garages. R316.5.1 Masonry or concrete construction. The thermal R315.2 Where required in existing dwellings. Where work barrier specified in Section R316.4 is not required in a requiring a permit occurs in existing dwellings that have masonry or concrete wall, floor or roof when the foam plas- attached garages or in existing dwellings within which tic insulation is separated from the interior of the building fuel -fired appliances exist, carbon monoxide alarms shall be by a minimum 1 -inch (25 mm) thickness of masonry or con provided in accordance with Section R315.1. crete. R315.3 Alarm requirements. Single station carbon monoxide R316.5.2 Roofing. The thermal barrier specified in Section alarms shall be listed as complying with UL 2034 and shall be R316.4 is not required when the foam plastic in a roof installed in accordance with this code and the manufacturer's assembly or under a roof covering is installed in accordance installation instructions. with the code and the manufacturer's installation instruc- tions and is separated from the interior of the building by tongue- and groove wood planks or wood structural panel SECTION R316 sheathing in accordance with Section R803, not less than FOAM PLASTIC 15 32 inch (11.9 mm) thick bonded with exterior glue and R316.1 General. The provisions of this section shall govern identified as Exposure 1, with edges supported by blocking the materials, design, application, construction and installation or tongue-and-groove joints or an equivalent material. The of foam plastic materials. smoke developed index for roof applications shall not be limited. R316.2 Labeling and identification. Packages and contain- ers of foam plastic insulation and foam plastic insulation R316.5.3 Attics. The thermal barrier specified in Section components delivered to the job site shall bear the label of an R316.4 is not required where all of the following apply: approved agencyshowing the manufacturer's name, the prod 1. Attic access is required by Section R807.1. uct listing, product identification and information sufficient to determine that the end use will comply with the require- 2. The space is entered only for purposes of repairs or ments. maintenance. 2009 INTERNATIONAL RESIDENTIAL CODE 63 04/04/2012 16:18 FAX 360 452 9265 Angeles Electric 160001 /0001 4 flt/ j A /Z Electrical Survey For City of Port Angeles Weatherization Program Homeowner: 04.A.) C9 t K h f tuw.*m 9S2-1433 Address: 332 ail 4/ eeT letbit vrt Rersii Si�.c,e. ern,✓ Insulation Installer: Electrical Contractor: „l y We have surveyed the wiring at the above location and have found the following in regards to the requirements of WAC 296 -46B -394 (see below): Attics: Yes No -7;17') Active knob tube wiring' (t Junction boxes covered r r Flying Splices N,4 15 A S fuses or breakers on knob tube circuits ELECTRICAL Wiring in good condition INSPECTIONS Wiring and circuit protection adequate to meet the load Electrical Work Performed: o.; ask I ran .edx/2.14 AtAeM*.. &WV 4 Notes: Walls: Yes No (tr 15 A S fuses or breakers on knob tube circuits Wiring in good condition (y� Wiring and circuit protection adequate to meet the load Electrical Work Performed: fit. t"qh I(, 001 Knob -and -tube wiring. /Iwr' V L P r Article 394 NEC does not prohibit the installation of loose or rolled thermal insulating material in spaces containing existing knob- and -tube wiring provided that all the following conditions are met: (1) The wiring must be surveyed by an appropriately licensed electrical contractor who must certify in writing to the department that the wiring is in good condition with no evidence of improper overcurrent protection, conductor insulation failure or deterioration, and with no improper connections or splices. The electrical inspector must inspect all repairs, alterations, or extensions to the electrical system. (2) The insulation must meet Class I specifications as identified in the Uniform Building Code, with a flame spread factor of twenty-five or less as tested using ASTM E84-81 a. Foam insulation may not be used with knob and -tube wiring. (3) All knob -and -tube circuits must have overcurrent protection in compliance with NEC Table 310.16, 60 degree centigrade, Column C. Overcurrent protection must be either circuit breakers or Type S fuses. Site Address: CITY OF PORT ANGELES LIGHT DEPARTMENT . ELECTRICAL PERMIT PERMIT NO. ":;>.;2 70 DATE 9'-/2.-9/ Installed By: o READY FOR INSPECTION License Number: o WILL CALL FOR INSPECTION Phone: Owner/Business: Phone: OwnerlBusiness Address: Sq. Ft. fI Residential Heat KW o Baseboard 0 Furnace/Boiler o Heatpump 0 Other o Commercial/Industrial load Total Connected load (attach breakdown) Total Motor load (attach breakdown) o New Construction ~ Remodel b Service update/alter/repair f'5: Overhead o Underground Voltage 010 03.0 Service size o Temporary ~ Add/alter circuits o Auxiliary power (list below) o Special equipment (list below) Amps DetailslDescrlption: cjJj- PfL ~.I:cp... -~;~ . W.S. No. Service Capacity: 0 O.K. 0 Not O.K. o Ditch inspection O.K. A rt:tJ Rough-in/cover O.K. . V b O.K. to connect service o Final OK Size Comments Date Hold for: 0 Easement 0 Letter o Signed up for service/meter o Meter Department notified for installation o Fire Department notified of inspection o Plan Review approved/pendi ng Installer: Site Address: . Notify the Department of City Light by Street Address and Permit Number when ready for inspection. Work must not be covered or electricaily energized before inspection and O.K. for covering or service has been given by the InspectQJjJ:ljAlUting on the Wiring Report or the Buiiding Permit. PHONE 457-0411, EXT. 158 or EXT. 224. ~ NO OCCUPANCY OR USE ESTABLISHED UNDER THIS PERMIT ~ tJ,Q ~ 0- Inspector .. Amount paid WHITE - file by address YELLOW - file by number PINK - Top: Eng, Bottom: Customer GREEN - Top: Inspector, Bottom: City Hall