Loading...
HomeMy WebLinkAbout809 W 5th St - Building )j . CITY OF PORT ANGELES LIGHT DEPARTMENT 321 E. Fifth Street Port Angeles, WA 98362 (206) 457-0411 Installed By: ELECTRICAL PERMIT y.e" PERMIT NO. ~J// '7/.;2.3 /93 / ' DATE Site Address: ,l!b READY FOR INSPECTION License Number: D WILL CALL FOR INSPECTION Phone: Owner/Business: Phone: OwnerfBusiness Address: Sq. Ft. C><l RESIDENTIAL b COMMERCIAL D BASEBOARD KW ~ FURNACE KW -LcL tJ FAN/WALL KW ~ HEAT PUMP KW---S:.- D SIGN D TEMPORARY SERVICE ':81- PERMANENT SERVICE (g" NEW CONSTRUCTION b REMODEL D ADD/ALTER CIRCUITS D SERVICE UPGRADE/REPAIR D SPECIAL EQUIPMENT (LIST BELOW) E1 If'<sEZ * OVERHEAD SERVICE ~ UNDERGROUND7.SERVICE VOLTAGE: aO zi/D Ja" SINGLE PHASE' D THREE PHASE SERVICE SIZE~OO AMPS DetailslDescription: /'IJ:u) ~~, . W.S. No. SERVICE SIZE CAPACITY: D O.K. NOT O.K. ACTION REQUIRED: D CHANGE TRANSFORMER D INSTALL SERVICE POLE DATE ENGR. D CHANGE SERVICE WIRE D OTHER D Ditch Inspection O.K. "~ Rough-in/cover O.K. .~ffJ O.K. to connect service N-NtFinalo.K. SltegOS: 1.1./, ~t-t Installer: New Meters .---- . Notify Port Angeles y Light by Street Address and Permit Numberwhen ready for inspection. Work must not be covered before inspection and O.K. for covering has been given by the electrical inspector in writing on either the Wiring Report or on the Building Permit. PHONE 457-0411, EXT. 224. .,/,/ &-e> '-, ~ NO OCCUPANCY OR USE ESTABLISHED UNDER THIS PERMIT $ 7/ SO - Etectricallnspector Permit Fee WHITE - File by address YELLOW - file by number PINK - Top: Eng, Bottom, Customer GREEN - Top: Meter Dept., Bottom: City Hall OLYMPIC PRINTERS INC . CITY OF PORT ANGELES LIGHT DEPARTMENT 321 E. Fifth Street Port Angeles, WA 98362 (206) 457-0411 PERMIT NO. lIz.D '1 7~S-/Y3 DATE ELECTRICAL PERMIT Site Address: 0. s--ft. Installed By: , IG o READY FOR INSPECTION License Number: o WI LL CALL FOR INSPECTION Phone: Owner/Business: Phone: Owner/Business Address: Sq. Ft. o RESIDENTIAL o COMMERCIAL o BASEBOARD KW _ o FURNACE KW o FAN/WALL KW o HEAT PUMP KW_ o SIGN )1 TEMPORARY SERVICE o PERMANENT SERVICE o NEW CONSTRUCTION o REMODEL o ADD/ALTER CIRCUITS o SERVICE UPGRADE/REPAIR o SPECIAL EQUIPMENT (LIST BELOW) ~ OVERHEAD SERVICE o UNDERGROU~CE YTAGE: /q:// . ~ ~INGLE PHAS~ o THREE PHASE SERVICE SIZE AMPS Details/Description: .~~/~, I . W.S. No. SERVICE SIZE CAPACITY: o O.K. NOT O.K. ACTION REQUIRED: 0 CHANGE TRANSFORMER o INSTALL SERVICE POLE DATE ENGR. o CHANGE SERVICE WIRE o OTHER o Ditch Inspection O.K. o Rough-in/cover O.K. ~ O.K. to connect service o Final O.K. . Site AdSO? W. s 1-4 Installer: C-ur?4( Notify Port Angeles City Light by Street Address and Permit Numberwhen ready for inspection. Work must not be covered before inspection and O.K. for covering has been given by the electrical inspector in writing on either the Wiring Report or on the Build~ Permit. PHONE 457-0411, EXT. 224. (%J ~~ NO OCCUPANCY OR USE ESTABLISHED UNDEA THIS PERMIT $ 0D ~ Electrical Inspector Permit Fee WHITE - File by address YELLOW - file by number PINK - Top: Eng, Bottom, Customer GREEN - Top: Meter Dept., Bottom: City Hall OLYMPIC PRINTERS INC. Application Number . . . . . 23-00000546 Date 5/26/23 Application pin number . . . 285224 Property Address . . . . . . 809 W 5TH ST ASSESSOR PARCEL NUMBER: 06-30-00-0-1-0262-0000- Application type description ELECTRICAL ONLY Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . RS7 RESDNTL SINGLE FAMILY Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc PV system and Battery backup ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ M EMIL AND JUDITH P MOILANEN BLOSSOM SOLAR LLC 142 LEWALLEN RD 1706 LOMBARD AVE PORT ANGELES WA 983632110 EVERETT WA 98201 (425) 610-7067 (425) 330-4322 ---------------------------------------------------------------------------- Permit . . . . . . ELECTRICAL ALTER RESIDENTIAL Additional desc . . Permit Fee . . . . 130.00 Plan Check Fee . . .00 Issue Date . . . . 5/26/23 Valuation . . . . 0 Expiration Date . . 11/22/23 Qty Unit Charge Per Extension 2.00 5.0000 ECH EL-BRANCH CIRCUIT W/FEEDER 10.00 1.00 120.0000 ECH EL-0-200 SRV FEEDER 120.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 130.00 130.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 130.00 130.00 .00 .00 1 - 2 SINGLE-FAMILY ELECTRICAL PERMIT APPLICATION Pub! ic \Yorks and ULili ties Department 32 l E. 5th Street. Port ;\ngeles. WJ\ 98362 300.417.47]5 ! www.cilyofjJa us I electricalpcnnitsr21/cityofpa.us Project Address:--------------------------------------­ Project Description:--------------------------------------□Single-Family Residential D Duplex/ ARU Building Square footage: _______________ _ OWNER JNFORMATtON Name: ________________________ Email: ______________ _ Mailing Address: ________________________ Phone: ___________ _ ELECTRfCAL CONTRACTOR fNFORMATION Name: ___________________________ License: ___________ _ Mailing Address: ________________________ Expiration Date: ________ _ Email: Phone: ___________ _ PROJECT DETAILS Item Unit Charge Qy51ntit3£ :To1s.l (Quantity x Unit Charge) Service/Feeder 200 Amp. $120.00 $ Service/Feeder 201-400 Amp. $146.00 $ Service/Feeder 401-600 Amp. $205.00 $ Service/Feeder 601-1000 Amp. $262.00 $ Service/Feeder over 1000 Amp. $373.00 $ Branch Circuit W/ Service Feeder $5.00 $ Branch Circuit W/O Service Feeder $63.00 $ Each Additional Branch Circuit $5.00 $ Branch Circuits 1-4 $75.00 $ Temp. Service/Feeder 200 Amp. $93.00 $ Temp. Service/Feeder 201-400 Amp. $110.00 $ Temp. Service/Feeder 401-600 Amp. $149.00 $ Temp. Service/Feeder 601-1000 Amp. $168.00 $ Portal to Portal Hourly $96.00 $ Signal CircuiULimited Energy - 1 &2 DU. $64.00 $ Manufactured Home Connection $120.00 $ Ren ewable Elec. Energy: 5KVA System or less $102.00 $ Thermostat (Note: $5 for each additional) $56.00 $ First 1300 Sql;Jare Feet $120.00 $ Each Additional 500 square feet" $40.00 $ Each Outbuilding / Detached Garage $74.00 $ Each Swimming Pool/ Hot Tub $110.00 $ TOTAL $ Owner as defined by RCW.19.28.261: (1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is required to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection. After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I am making the electrical installation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296- 468, The City of Port Angeles Municipal Code, and Utility Specifications and PAMC 14.05.050 regarding Electrical Permit Applications. Date Print Name Signature (0 Owner D Electrical Contractor/ Administrator) [Electrical Permit Applications may be submitted to City Hall or electricalpermits@cityofpa.us] '"'CJ CD PREPARED 5/24/23,11:36:55 PAYMENT DUE CITY OF PORT ANGELES PROGRAM BP820L --------------------------------------------------------------------------- APPLICATION NUMBER:23-00000546 809 W 5TH ST FEE DESCRIPTION AMOUNT DUE --------------------------------------------------------------------------- ELECTRICAL ALTER RESIDENTIAL 130.00 TOTAL DUE 130.00 Please present reciept to the cashier with full payment 13 8 ' - 5 "50'-3"13 8 ' - 5 "48'-9"7'-5"34 ' - 6 "5'-0"31'-4"UMMSPPV-014/1/2023SHEET TITLEDRAWN DATEDRAWN BYPCADSHEET NUMBERSYSTEM DETAILSPHONE - (425) 610-7067REVDATEDESCRIPTIONREVISIONSDC SIZE: 14.800 KW DC-(STC)AC SIZE: 11.600 KW AC(40) SILFAB SOLAR SIL-370 HC(40) ENPHASE IQ8PLUS-72-2-US [240V]CONTRACTORPROJECT NAME & ADDRESS1706 LOMBARD AVEEVERETT, WA 98201BLOSSOM SOLARAPN #: 0630000102620000AHJ: CITY OF PORT ANGELESUTILITY: CITY OF PORT ANGELESEMIL MOILANEN809 W 5TH ST ,PORT ANGELES, WA 98363VICINITY MAPSATELLITE VIEWCOVER PAGESHEET INDEXCOVER PAGEPV-01NOTESSITE PLANELECTRICAL DIAGRAMWARNING LABELSATTACHMENT PLAN & DETAILSPROJECT NOTES1.1.1 THIS PHOTOVOLTAIC (PV) & ENERGY STORAGE SYSTEMSHALL COMPLY WITH THE RELEVANT YEAR OF THE NATIONALELECTRIC CODE (NEC), ALL MANUFACTURER’S LISTING ANDINSTALLATION INSTRUCTIONS, AND THE RELEVANT CODES ASSPECIFIED BY THE AUTHORITY HAVING JURISDICTION’S (AHJ)APPLICABLE CODES.1.1.2 THE UTILITY INTERCONNECTION APPLICATION MUST BEAPPROVED AND THE PV & ENERGY STORAGE SYSTEM MUST BEINSPECTED PRIOR TO OPERATION1.1.3 ALL PV & ENERGY STORAGE SYSTEM COMPONENTS;MODULES, UTILITY-INTERACTIVE INVERTERS, BATTERIES, ANDSOURCE CIRCUIT COMBINER BOXES ARE IDENTIFIED AND LISTEDFOR USE IN PHOTOVOLTAIC SYSTEMS AS REQUIRED BY NEC ANDOTHER GOVERNING CODES1.1.4 ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCALBUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UVRESISTANT. ALL PLAQUES AND SIGNAGE WILL BE INSTALLED ASREQUIRED BY THE NEC AND AHJ.STRING DIAGRAMPV-02PV-03PV-05PV-07PV-08SCALE:1"-20'-0"PROPERTY PLANPV-011NEW PHOTOVOLTAIC ROOF MOUNTED SYSTEM - 14.80 KW DC/11.600 KW AC& ENERGY STORAGE SYSTEM - 10.5 KWH809 W 5TH ST , PORT ANGELES, WA 98363LEGEND- PROPERTY LINE- FENCE LINEBATTERY:(1) ENCHARGE-10-1P-NA [240V]SCOPE OF WORK1.2.1 CONTRACTOR IS RESPONSIBLE FOR THE DESIGN ANDSPECIFICATIONS OF THE GRID-TIED PHOTOVOLTAIC & ENERGYSTORAGE SYSTEM. THE CONTRACTOR WILL BE RESPONSIBLEFOR COLLECTION OF EXISTING ONSITE CONDITIONS TO DESIGN,SPECIFY, AND INSTALL THE ROOF-MOUNTED PV SYSTEM ANDENERGY STORAGE SYSTEM DETAILED IN THIS DOCUMENTDESIGN CRITERIAROOF SURFACE TYPE: STANDING SEAM METALROOF FRAMING: 2"X6" RAFTER @ 24" OCBUILDING STORY: ONE STORYGROUND SNOW LOAD: 0 PSFROOF SNOW LOAD:25 PSFSOIL BEARING CAPACITY:1500 LBSWIND SPEED: 110 MPHWIND EXPOSURE: CRISK CATEGORY: IINOTES:1. ROOF ACCESS POINT SHALL NOT BE LOCATEDIN AREAS THAT REQUIRE THE PLACEMENT OFGROUND LADDERS OVER OPENINGS SUCH ASWINDOWS OR DOORS, AND LOCATED ATSTRONG POINTS OF BUILDING CONSTRUCTIONIN LOCATIONS WHERE THE ACCESS POINT DOESNOT CONFLICT WITH OVERHEAD OBSTRUCTIONSSUCH AS TREE LIMBS, WIRES OR SIGNS.2. STRUCTURES, PATIO COVERS, AND/ORADDITIONS BUILT WITHOUT PERMITS TO BERESOLVED BY A SEPARATE PERMIT.NEW PV SYSTEM SPECIFICATIONSSYSTEM SIZE:DC SIZE: 14.800 KW DC-(STC)AC SIZE: 11.600 KW ACMODULE:(40) SILFAB SOLAR SIL-370 HCINVERTER:(40) ENPHASE IQ8PLUS-72-2-US [240V](E) UTILITY METER(UNDERGROUND SERVICE)(40) SILFAB SOLAR SIL-370 HCMODULES WITH ENPHASEIQ8PLUS-72-2-US [240V]UNDER EACH MODULEROOF ACCESS POINTFENCERESOURCE DOCUMENTR-01 -> R-15PV-06W 5TH STG A R A G E M A I N H O U S E SHEDSHED(E) MAIN SERVICE PANELAPPLICABLE CODESALL WORK SHALL CONFORM TO THE FOLLOWING CODES:2018 INTERNATIONAL BUILDING CODE2018 INTERNATIONAL RESIDENTIAL CODE2018 INTERNATIONAL EXISTING BUILDING CODE2018 INTERNATIONAL FIRE CODE2018 WASHINGTON STATE ENERGY CODE2020 NATIONAL ELECTRICAL CODEAS ADOPTED BY CITY OF PORT ANGELESPV-04EQIPMENTS ELEVATIONW 4TH STD R I V E W A Y PV-04.1FLOOR PLAN 36" FIRE SETBACK18" FIRE SETBACK18" FIRE SETBACK 18 " F I R E S E T B A C K 18 " F I R E S E T B A C K 36" FIRE SETBACK4 1 1 1 1 1 1 1 1 1 2 1 22222223333333 2 2333444444444 UMMSPRSDSC2CBESSACDJB SUBPV-024/1/2023SHEET TITLEDRAWN DATEDRAWN BYPCADSHEET NUMBERSYSTEM DETAILSPHONE - (425) 610-7067REVDATEDESCRIPTIONREVISIONSDC SIZE: 14.800 KW DC-(STC)AC SIZE: 11.600 KW AC(40) SILFAB SOLAR SIL-370 HC(40) ENPHASE IQ8PLUS-72-2-US [240V]CONTRACTORPROJECT NAME & ADDRESS1706 LOMBARD AVEEVERETT, WA 98201BLOSSOM SOLARAPN #: 0630000102620000AHJ: CITY OF PORT ANGELESUTILITY: CITY OF PORT ANGELESEMIL MOILANEN809 W 5TH ST ,PORT ANGELES, WA 98363ROOF SECTION(S)SLOPE - 18°AZIMUTH - 121°MODULE QTY- 06RAFTER - 2"X6" @ 24" O.C.SURFACE TYPE- STANDING SEAM METALSEAM SPACING- 12" O.C.ROOF 2SLOPE - 18°AZIMUTH - 121°MODULE QTY - 34RAFTER - 2"X6" @ 24" O.C.SURFACE TYPE- STANDING SEAM METALSEAM SPACING- 12" O.C.ROOF 11- MODULE STRING2- MODULE STRING3- MODULE STRING4- MODULE STRINGSITE PLANNOTE:TO AVOID ADDITIONAL TEMPERATURE DERATECORRECTIONS, CONDUIT MUST BE A MINIMUM OF7/8” ABOVE THE ROOF SURFACE (EXTERIOR) OR 18”BELOW ROOF THROUGH ATTIC (INTERIOR).PLAN VIEW TOTAL ROOF AREA:2379 FT²TOTAL PV ARRAY AREA:845.31 FT²TOTAL % OF ROOF COVERED BY PV:35.53%PV CIRCUITSLEGEND- JUNCTION BOXJB- VENT, ATTIC FAN (ROOF OBSTRUCTION)- CHIMNEY (ROOF OBSTRUCTION)- SKYLIGHT (ROOF OBSTRUCTION)- CONDUIT RUN- (40) SILFAB SOLAR SIL-370 HC MODULESWITH ENPHASE IQ8PLUS-72-2-US [240V]MICROINVERTERS UNDER EACH MODULESCALE:3/32" = 1'-0"SITE PLANPV-021ROOF 1(40) SILFAB SOLAR SIL-370 HCMODULES WITH ENPHASEIQ8PLUS-72-2-US [240V] UNDEREACH MODULEROOF ACCESS POINT(N) JUNCTION BOXNEMA 3RFRONT OF HOUSEBACK OF HOUSE(N) VISIBLE-OPEN, LOCKABLE,LABELED AND FUSED AC DISCONNECTROOF 2(N) RAPID SHUTDOWN DEVICE(E) UTILITY METER(UNDERGROUND SERVICE)(E) MAIN SERVICE PANEL(N) ENPHASE SYSTEMCONTROLLER 2(N) BACKUP LOAD PANEL(N) ENCHARGE 10 BATTERY(N) AC COMBINER PANELW 5TH STW 4TH ST 18" FIRE SETBACK9"48'-8"6"4'-0"ATTACHMENT SPACING17'-1" FLAT 18" FIRE SETBACK36" FIRE SETBACK6'-2"10'-4"6'-2"12'-7" FLATPV MODULE(E) STANDING SEAM METAL ROOFSEE ENLARGED VIEWScale: NTSATTACHMENT DETAILPV-032Scale: NTSENLARGED VIEWPV-033IRONRIDGE AIRE INTEGRATEDGROUNDING & MID/END CLAMPIRONRIDGE AIRERAILIRONRIDGE AIREDOCKALL PURPOSE L FOOT(E) STANDING SEAM METALROOFS-5-U CLAMP ATTACHMENTPV-034/1/2023SHEET TITLEDRAWN DATEDRAWN BYPCADSHEET NUMBERSYSTEM DETAILSPHONE - (425) 610-7067REVDATEDESCRIPTIONREVISIONSDC SIZE: 14.800 KW DC-(STC)AC SIZE: 11.600 KW AC(40) SILFAB SOLAR SIL-370 HC(40) ENPHASE IQ8PLUS-72-2-US [240V]CONTRACTORPROJECT NAME & ADDRESS1706 LOMBARD AVEEVERETT, WA 98201BLOSSOM SOLARAPN #: 0630000102620000AHJ: CITY OF PORT ANGELESUTILITY: CITY OF PORT ANGELESEMIL MOILANEN809 W 5TH ST ,PORT ANGELES, WA 98363ATTACHMENT PLAN& DETAILSATTACHMENT PLANSCALE: NTSPV-031- ATTACHMENT POINTS- RAIL- RAFTER/TRUSS/SEAMTOTAL ATTACHMENT POINTS - 96LEGENDPOINT LOAD CALCULATIONSMODULE TYPESILFAB SOLAR SIL-370 HCMODULE WEIGHT43 LBSNUMBER OF MODULES40TOTAL WEIGHT OF MODULES1720.00 LBSTYPE OF RACKINGIRONRIDGE AIRE RAILDISTRIBUTED WEIGHT OF RACKING0.5 PSFTOTAL WEIGHT OF ARRAY2142.66 LBSTYPE OF ATTACHMENTS-5-U CLAMP ATTACHMENTSNUMBER OF ATTACHMENTS96POINT LOAD AT EACH ATTACHMENT17.93 LBSAREA OF MODULE21.13 SQFT.TOTAL ARRAY AREA845.31 SQFT.DISTRIBUTED LOAD2.06 PSFTOTAL PLAN VIEW ROOF AREA2379 SQFT.PERCENTAGE OF TOTAL ROOFCOVERED BY ARRAY35.53 %ROOF SECTION(S)SLOPE - 18°AZIMUTH - 121°MODULE QTY- 06RAFTER - 2"X6" @ 24" O.C.SURFACE TYPE- STANDING SEAM METALROOF 2SLOPE - 18°AZIMUTH - 121°MODULE QTY - 34RAFTER - 2"X6" @ 24" O.C.SURFACE TYPE- STANDING SEAM METALROOF 1NOTE: CONTRACTOR/INSTALLER TO VERIFY COMPATIBILITY OF ANYBRANDS OR PRODUCTS SUBSTITUTED OR USED AS ALTERNATESWITHIN ANY BRAND-SPECIFIC SYSTEMS. CONTRACTOR SHALLSUPPLY AND PRESENT CERTIFICATES OF COMPATIBILITY TO THEBUILDING OFFICIAL UPON INSPECTION AS NEEDED.ROOF 2ROOF 1METAL SEAM SPACING = 12" O.C. TO PVTO MSPFROM UTILITYMETERTO ACDFROMMSPTO IQCONTROLLER2FROM ACDTO RSDFROM IQCONTROLLER2PV-044/1/2023SHEET TITLEDRAWN DATEDRAWN BYPCADSHEET NUMBERSYSTEM DETAILSPHONE - (425) 610-7067REVDATEDESCRIPTIONREVISIONSDC SIZE: 14.800 KW DC-(STC)AC SIZE: 11.600 KW AC(40) SILFAB SOLAR SIL-370 HC(40) ENPHASE IQ8PLUS-72-2-US [240V]CONTRACTORPROJECT NAME & ADDRESS1706 LOMBARD AVEEVERETT, WA 98201BLOSSOM SOLARAPN #: 0630000102620000AHJ: CITY OF PORT ANGELESUTILITY: CITY OF PORT ANGELESEMIL MOILANEN809 W 5TH ST ,PORT ANGELES, WA 98363EQUIPMENTELEVATION(N) UTILITYMETER(N) RAPID SHUTDOWN DEVICE(N) ENPHASE SYSTEMCONTROLLER 2(N) ACDISCONNECT(N) BACKUP LOAD PANEL(N) ENCHARGE 10BATTERY(N) COMBINER PANEL(E) MAIN SERVICEPANELNORTH-WEST WALL(OUTSIDE)(INSIDE)FLOORScale: NTSEQUIPMENT ELEVATION1 1 2 3 8 7 6 5 4 PV-04.14/1/2023SHEET TITLEDRAWN DATEDRAWN BYPCADSHEET NUMBERSYSTEM DETAILSPHONE - (425) 610-7067REVDATEDESCRIPTIONREVISIONSDC SIZE: 14.800 KW DC-(STC)AC SIZE: 11.600 KW AC(40) SILFAB SOLAR SIL-370 HC(40) ENPHASE IQ8PLUS-72-2-US [240V]CONTRACTORPROJECT NAME & ADDRESS1706 LOMBARD AVEEVERETT, WA 98201BLOSSOM SOLARAPN #: 0630000102620000AHJ: CITY OF PORT ANGELESUTILITY: CITY OF PORT ANGELESEMIL MOILANEN809 W 5TH ST ,PORT ANGELES, WA 98363FLOOR PLANScale: NTSFLOOR PLAN16RAPID SHUTDOWN DEVICEENPHASE ENCHARGE BATTERY7BACKUP PANEL821MAIN SERVICE PANEL3ENPHASE ENPOWER SWITCHUTILITY METER45COMBINER PANELUTILITY DISCONNECTFRONT OF GARAGEGARAGE'S DOORDOOR GN70A/2P20A/2P200A FACTORY WIRINGNFT (AUTOTRANSFORMER)AC COMBINERIQ BATTERYGENERATORIQ BATTERYAC COMBINERIQ GATEWAY/GENERATOR(N) ENPHASE SYSTEM CONTROLLER 2200A, NEMA 3R, 120/240VN/C3N/C4WIRELESSCOMMS2AC ~DC ±BATTERY+-L2L1GL2L1G(N) ENPHASEENCHARGE-10-1P-NA [240V]BATTERY(2) #10 AWG THWN-2(1) #8 AWG THWN-2 GRND3/4" EMT CONDUIT(N) ENPHASERAPIDSHUTDOWNSWITCH(4) #12 AWG THWN-2(1) 3/4" EMT CONDUITGN(N) 60A/2PMAIN BREAKER(N) 100A BACKUPLOADS PANEL,NEMA 3R, 120/240V,1-PHASEGL1L2NESS HOLD DOWNKIT BRHDK125 ISREQUIRED PERNEC 705.154GN20A/2PIQ GATEWAY15A/2P(N) ENPHASE COMBINER PANELNEMA 3R, UL LISTED,125A RATEDCELLMODEMWIRELESSCOMMS10A OR 15A BREAKER ISSUITABLE FOR USE20A/2P20A/2P20A/2PENPHASE QCABLE(S)SILFAB SOLAR SIL-370 HC10 MICROINVERTERS IN STRING 110 MICROINVERTERS IN STRING 210 MICROINVERTERS IN STRING 310 MICROINVERTERS IN STRING 4313(N) JUNCTION BOX600 V, NEMA 3RUL LISTEDENPHASE IQ8PLUS-72-2-US [240V]MICROINVERTERS ONE UNDEREACH PANEL (240V)L2L1GL2L1(N) JUNCTION BOX600 V, NEMA 3RUL LISTEDL2L1GL2L1LOADLINEGL1L2N(N) SERVICE RATEDAC DISCONNECT:VISIBLE, LOCKABLE, LABELED100A FUSED, (2) 90A FUSES,240V, NEMA 3R, UL LISTEDL1L2BONDEDNSUPPLY SIDEINTERCONNECTIONAT MAIN PANELGMN(E) 200A MAINSERVICE PANEL,240V(E) 200A/2P MAINBREAKER, 240VSUPPLY SIDECONNECTIONL2NL2L1TO UTILITY GRIDLINELOAD(E) BI-DIRECTIONALUTILITY METER1-PHASE, 3-W,120V/240VEXISTING GROUNDINGELECTRODE SYSTEMGEC33(ENPHASE X-IQ-AM1-240-4C)(E) OR (N) GROUNDINGELECTRODE SYSTEMGEC#8 OR #6 OR #4 GROUNDINGELECTRODE CONDUCTORPV-054/1/2023SHEET TITLEDRAWN DATEDRAWN BYPCADSHEET NUMBERSYSTEM DETAILSPHONE - (425) 610-7067REVDATEDESCRIPTIONREVISIONSDC SIZE: 14.800 KW DC-(STC)AC SIZE: 11.600 KW AC(40) SILFAB SOLAR SIL-370 HC(40) ENPHASE IQ8PLUS-72-2-US [240V]CONTRACTORPROJECT NAME & ADDRESS1706 LOMBARD AVEEVERETT, WA 98201BLOSSOM SOLARAPN #: 0630000102620000AHJ: CITY OF PORT ANGELESUTILITY: CITY OF PORT ANGELESEMIL MOILANEN809 W 5TH ST ,PORT ANGELES, WA 98363ELECTRICALDIAGRAMMICROINVERTER SPECIFICATIONSMANUFACTURER / MODEL #ENPHASE IQ8PLUS-72-2-US [240V]MIN/MAX DC VOLT RATING22V MIN/ 60V MAXMAX INPUT POWER235W-440WNOMINAL AC VOLTAGE RATING240V/ 211-264VMAX AC CURRENT1.21AMAX MODULES PER STRING13 (SINGLE PHASE)MAX OUTPUT POWER290WAMBIENT TEMPERATURE SPECIFICATIONSRECORD LOW TEMP-6°CAMBIENT TEMP (HIGH TEMP 2% AVG.)25°CCONDUIT HEIGHT7/8"CONDUCTOR TEMPERATURE RATE90°CSOLAR MODULE SPECIFICATIONSMANUFACTURER / MODEL #SILFAB SOLAR SIL-370 HCVMP34.95VIMP10.60AVOC41.75VISC11.25ATEMP. COEFF. VOC-0.28%/°CMODULE DIMENSION73.97" x 41.14"DESCRIPTIONFORMULARESULTPV OVERCURRENT PROTECTION NEC 690.9(B) TOTAL INVERTER OUTPUT CURRENT x 1.25 = (40 x 1.21)A x 1.2560.50A (SELECTED OCPD = 70A)WIRE IDEXPECTED WIRETEMP (°C)TEMPDERATE(90 °C)QTY OF CURRENTCARRYINGCONDUCTORSCONDUIT FILLDERATECONDUITSIZE &TYPEWIRE GUAGE& TYPECONDUCTORAMPACITY @90°C (A)CONDUCTORAMPACITY @75°C (A)REQUIRED CIRCUITCONDUCTORAMPACITY (A)ADJUSTEDCONDUCTORAMPACITY @ 90 °C (A)NEUTRALCONDUCTORSIZE & TYPEGROUND WIRESIZE & TYPE1251.0480.703/4" EMT#10 THWN-2403515.1329.12NONE#8 THWN-22251.0421.001" EMT#4 THWN-2958560.5098.80#4 THWN-2#8 THWN-23251.0421.001-1/4" PVC#3 THWN-211510080.50119.60#3 THWN-2#8 THWN-24251.0421.001" EMT#6 THWN-2756560.5078.00#6 THWN-2#10 THWN-25#6 SBCESS ENERGY CAPACITY SHALL BE SIZEDTO SUPPLY ALL DESIRED LOADS DURINGAN OUTAGE. POWER CAPACITY OF THEESS SHALL BE CAPABLE OF SUPPLYINGTHE LARGEST LOAD ON SITE, PER 2017NEC 710.15(A) & NEC710.15(E)1.IQ GATEWAY TO BE POWERED FROM GENERATOR BREAKERSLOT FOR ENPOWER R2 SYSTEMS2.SYSTEM CONTROLLER 2 IS 200A SERVICE ENTRANCE RATED3.INSTALL USB COMMS KIT AND CELL MODEM KIT AS NEEDED4.IQ BATTERY AND PV BREAKER(S) REQUIRE EATON HOLDDOWN KIT (BRHDK125).5.ATTENTION: TO PREVENT COMPLICATION BE SURE TOPOWER DOWN SYSTEM CONTROLLER 2 BEFORECONNECTING THE SHUTDOWN SWITCHCOMMUNICATION NOTES:- ETHERNET COMMUNICATION TO BE RUN FROM THE INTERNET ROUTER TOTHE ENPHASE IQ COMBINER.- WIRELESS COMMUNICATION KIT NEEDED FOR COMMUNICATION BETWEENENVOY (COMMS KIT-01). TO BE INSTALLED AT THE IQ ENVOY FORCOMMUNICATION WITH ENCHARGE AND CONTROLLER 2.INCLUDES USB CABLE FOR CONNECTION TO ENVOY/IQ COMBINER ANDALLOWSWIRELESS COMMUNICATION WITH ENCHARGE AND CONTROLLER 2 PV-064/1/2023SHEET TITLEDRAWN DATEDRAWN BYPCADSHEET NUMBERSYSTEM DETAILSPHONE - (425) 610-7067REVDATEDESCRIPTIONREVISIONSDC SIZE: 14.800 KW DC-(STC)AC SIZE: 11.600 KW AC(40) SILFAB SOLAR SIL-370 HC(40) ENPHASE IQ8PLUS-72-2-US [240V]CONTRACTORPROJECT NAME & ADDRESS1706 LOMBARD AVEEVERETT, WA 98201BLOSSOM SOLARAPN #: 0630000102620000AHJ: CITY OF PORT ANGELESUTILITY: CITY OF PORT ANGELESEMIL MOILANEN809 W 5TH ST ,PORT ANGELES, WA 98363NOTESSITE NOTES2.1.1 A LADDER WILL BE IN PLACE FOR INSPECTION IN ACCORDANCEWITH OSHA REGULATIONS.2.1.2 THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE ANDTHIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM WITH STORAGEBATTERIES.2.1.3 THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANYPLUMBING, MECHANICAL, OR BUILDING ROOF VENTS.2.1.4 PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTINGAND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED INACCORDANCE WITH SECTION NEC 110.26.2.1.5 ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, ANDMAINTAINED IN ACCORDANCE WITH THIS CODE AND THE APPROVEDMANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERINGSERVES TO PROTECT THE BUILDING OR STRUCTURE.EQUIPMENT LOCATIONS2.2.1 ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS INACCORDANCE WITH NEC 110.26.2.2.2 WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BERATED FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED BYNEC 690.31 (A),(C) AND NEC TABLES 310.15 (B)(2)(A) AND 310.15 (B)(3)(C).2.2.3 JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PVMODULES IN ACCORDANCE WITH NEC 690.34.2.2.4 ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THEINVERTER IS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT.2.2.5 ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIEDPERSONNEL IN ACCORDANCE WITH NEC APPLICABLE CODES.2.2.6 ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATEDFOR OUTDOOR USAGE WHEN APPROPRIATE.STRUCTURAL NOTES2.3.1 RACKING SYSTEM & PV ARRAY WILL BE INSTALLED INACCORDANCE WITH THE CODE-COMPLIANT INSTALLATION MANUAL.TOP CLAMPS REQUIRE A DESIGNATED SPACE BETWEEN MODULES,AND RAILS MUST ALSO EXTEND A MINIMUM DISTANCE BEYOND EITHEREDGE OF THE ARRAY/SUB-ARRAY, IN ACCORDANCE WITH RAILMANUFACTURER’S INSTALLATION PRACTICES.2.3.2 JUNCTION BOX WILL BE INSTALLED PER MANUFACTURER'SSPECIFICATIONS. IF ROOF-PENETRATING TYPE, IT SHALL BE FLASHED& SEALED PER LOCAL REQUIREMENTS.2.3.3 ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BECOMPLETED AND SEALED W/ APPROVED CHEMICAL SEALANT PERCODE BY A LICENSED CONTRACTOR.2.3.4 ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NOGREATER THAN THE SPAN DISTANCE SPECIFIED BY THE RACKINGMANUFACTURER OR PROFESSIONAL ENGINEERING GUIDANCE.2.3.5 WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILLBE STAGGERED AMONGST THE ROOF FRAMING MEMBERS.WIRING & CONDUIT NOTES2.4.1 ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FORTHEIR PURPOSE. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ONMINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMITUP-SIZING.2.4.2 CONDUCTORS SIZED IN ACCORDANCE WITH THE NEC2.4.3 AC CONDUCTORS TO BE COLORED OR MARKED PER NECGROUNDING NOTES2.5.1 GROUNDING SYSTEM COMPONENTS SHALL BE LISTEDFOR THEIR PURPOSE, AND GROUNDING DEVICES EXPOSED TOTHE ELEMENTS SHALL BE RATED FOR SUCH USE.2.5.2 PV EQUIPMENT SHALL BE GROUNDED IN ACCORDANCEWITH NEC 690.43 AND NEC TABLE 250.122.2.5.3 METAL PARTS OF MODULE FRAMES, MODULE RACKING,AND ENCLOSURES CONSIDERED GROUNDED IN ACCORDANCEWITH NEC 250.134 AND 250.136(A).2.5.4 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZEDIN ACCORDANCE WITH NEC 690.45 AND INVERTERMANUFACTURER'S INSTALLATION PRACTICES2.5.5 EACH MODULE WILL BE GROUNDED AS SHOWN INMANUFACTURER DOCUMENTATION AND APPROVED BY THEAHJ.2.5.6 THE GROUNDING CONNECTION TO A MODULE SHALL BEARRANGED SUCH THAT THE REMOVAL OF A MODULE DOESNOT INTERRUPT A GROUNDING CONDUCTOR TO ANOTHERMODULE.2.5.7 GROUNDING AND BONDING CONDUCTORS, IF INSULATED,SHALL BE COLORED GREEN OR MARKED GREEN IF #4 AWG ORLARGER PER NEC 250.1192.5.8 THE GROUNDING ELECTRODE SYSTEM COMPLIES WITHNEC 690.47 AND NEC 250.50 THROUGH 250.106. IF EXISTINGSYSTEM IS INACCESSIBLE, OR INADEQUATE, A GROUNDINGELECTRODE SYSTEM PROVIDED IN ACCORDANCE WITH NEC250, NEC 690.47 AND THE AHJ.2.5.9 GROUND-FAULT DETECTION SHALL COMPLY WITH NEC690.41(B)(1) AND (2) TO REDUCE FIRE HAZARDSDISCONNECTION AND OVERCURRENT PROTECTION NOTES2.6.1 DISCONNECTING SWITCHES SHALL BE WIRED SUCH THATWHEN THE SWITCH IS OPENED THE CONDUCTORS REMAININGENERGIZED ARE CONNECTED TO THE TERMINALS MARKED“LINE SIDE” (TYPICALLY THE UPPER TERMINALS).2.6.2 DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITYPERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH2.6.3 PV SYSTEM CIRCUITS INSTALLED ON OR IN HABITABLEBUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION TOREDUCE SHOCK HAZARD FOR EMERGENCY RESPONDERS INACCORDANCE WITH 690.122.6.4 ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDINGTO NEC 690.8, 690.9, AND 240.2.6.5 INVERTER ON-GRID BRANCHES SHALL BE CONNECTED TOA SINGLE BREAKER OR GROUPED FUSE DISCONNECT(S) INACCORDANCE WITH NEC 110.3(B).2.6.6 IF REQUIRED BY THE AHJ, SYSTEM WILL INCLUDEARC-FAULT CIRCUIT PROTECTION IN ACCORDANCE WITH NEC690.11 AND UL1699B.INTERCONNECTION NOTES2.7.1 LOAD SIDE INTERCONNECTION SHALL BE INACCORDANCE WITH NEC 705.12.2.7.2 THE SUM OF THE UTILITY OCPD AND INVERTERCONTINUOUS OUTPUT MAY NOT EXCEED 120 PERCENT OFBUSBAR RATING PER NEC 705.12.2.7.3 THE SUM OF 125 PERCENT OF THE POWER SOURCE(S)OUTPUT CIRCUIT CURRENT AND THE RATING OF THEOVERCURRENT DEVICE PROTECTING THE BUSBAR SHALLNOT EXCEED 120 PERCENT OF THE AMPACITY OF THEBUSBAR, PV DEDICATED BACKFEED BREAKERS MUST BELOCATED OPPOSITE END OF THE BUS FROM THE UTILITYSOURCE OCPD PER NEC 705.12.2.7.4 AT MULTIPLE ELECTRIC POWER SOURCES OUTPUTCOMBINER PANEL, TOTAL RATING OF ALL OVERCURRENTPROTECTION DEVICES SHALL NOT EXCEED AMPACITY OFBUSBAR. HOWEVER, THE MAIN OVERCURRENT PROTECTIONDEVICE MAY BE EXCLUDED IN ACCORDANCE WITH NEC705.12.2.7.5 FEEDER TAP INTERCONNECTION (LOAD SIDE) INACCORDANCE WITH NEC 705.12.2.7.6 SUPPLY SIDE TAP INTERCONNECTION IN ACCORDANCEWITH TO NEC 705.12 WITH SERVICE ENTRANCECONDUCTORS IN ACCORDANCE WITH NEC 230.42.2.7.7 BACKFEEDING BREAKER FOR ELECTRIC POWERSOURCES OUTPUT IS EXEMPT FROM ADDITIONALFASTENING PER NEC 705.12.GENERAL NOTES UM MSP RSD SC2 CB ESS ACD JBSUB PV-074/1/2023SHEET TITLEDRAWN DATEDRAWN BYPCADSHEET NUMBERSYSTEM DETAILSPHONE - (425) 610-7067REVDATEDESCRIPTIONREVISIONSDC SIZE: 14.800 KW DC-(STC)AC SIZE: 11.600 KW AC(40) SILFAB SOLAR SIL-370 HC(40) ENPHASE IQ8PLUS-72-2-US [240V]CONTRACTORPROJECT NAME & ADDRESS1706 LOMBARD AVEEVERETT, WA 98201BLOSSOM SOLARAPN #: 0630000102620000AHJ: CITY OF PORT ANGELESUTILITY: CITY OF PORT ANGELESEMIL MOILANEN809 W 5TH ST ,PORT ANGELES, WA 98363WARNING LABELSMULTIPLE SOURCES OF POWER.POWER TO THIS BUILDING IS ALSO SUPPLIEDFROM THE FOLLOWING SOURCES WITHDISCONNECTS LOCATED AS SHOWN:CAUTIONUTILITY METERJUNCTION BOX(E) PV ARRAYBACKUP LOAD PANELBATTERYAC DISCONNECTAC COMBINERLABEL LOCATION: RSD INITIATION DEVICE, AC DISCONNECTPER CODE: NEC 690.56(C)(2)ELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONWARNINGLABEL LOCATION: COMBINER PANEL, ACDISCONNECT, POINT OF INTERCONNECTIONPER CODE: NEC 706.15(C)(4), NEC 690.13(B)WARNINGDUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEMLABEL LOCATION: MAIN SERVICE DISCONNECT, PRODUCTION/NET METERPER CODE: NEC 690.59, 705.12(C)LABEL LOCATION: MAIN SERVICE DISCONNECT, UTILITY METERPER CODE: NEC 690.13(B)POWER SOURCE OUTPUTCONNECTION. DO NOT RELOCATETHIS OVERCURRENT DEVICE.WARNINGLABEL LOCATION: POINT OF INTERCONNECTIONPER CODE: NEC 705.12(B)(3)(2)LABEL LOCATION: AC DISCONNECTPER CODE: NEC 705.12(B)(3)(3)TURN OFF PHOTOVOLTAIC ACDISCONNECT PRIOR TOWORKING INSIDE PANELWARNINGLABEL LOCATION: COMBINER PANEL(S), MAIN SERVICE DISCONNECTPER CODE: NEC 110.27(C), OSHA 1910.145(f)(7)ELECTRICAL SHOCK HAZARDTERMINALS ON BOTH LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONWARNINGDC VOLTAGE IS ALWAYS PRESENT WHENSOLAR MODULES ARE EXPOSED TO SUNLIGHTLABEL LOCATION: DC DISCONNECTPER CODE: NEC 690.13(B)LABEL LOCATION: AC DISCONNECTPER CODE: NEC 690.13(B)LABEL LOCATION: MAIN SERVICE DISCONNECTPER CODE: NEC 690.56(C)!!!!!PHOTOVOLTAIC POWER SOURCELABEL LOCATION: DC CONDUIT/RACEWAYSPER CODE: NEC 690.31(D)(2)SOLAR PV DC CIRCUITLABEL LOCATION: DC CONDUIT/RACEWAYSPER CODE: NEC 690.31(D)(2)LABEL LOCATION: AC DISCONNECT/POINT OF INTERCONNECTIONPER CODE: NEC 690.54PHOTOVOLTAIC SYSTEM AC DISCONNECTRATED AC OUPUT CURRENT:48.40 ANOMINAL OPERATING AC VOLTAGE:240 VTHIS EQUIPMENT FED BY MULTIPLESOURCES:TOTAL RATING OF ALL OVERCURRENTDEVICES EXCLUDING MAIN POWERSUPPLY SHALL NOT EXCEEDAMPACITY OF BUSBARWARNING!LABEL LOCATION: MAIN SERVICE DISCONNECTPER CODE: NEC 705.12(D), NEC 690.59CAUTIONPHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED!SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNSOLAR ELECTRICPV PANELSTURN RAPID SHUTDOWNSWITCH TO THE"OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCESHOCK HAZARDIN THE ARRAYDO NOT DISCONNECTUNDER LOADLABEL LOCATION: MAIN SERVICE DISCONNECTPER CODE: NEC 690.15(B) & NEC 690.33(D)(2)LABEL LOCATION: DC DISCONNECT/INVERTER/PV DIST.EQUIPMENTPER CODE: NEC 690.53MAXIMUM DC VOLTAGEOF PV SYSTEMPV SYSTEMDISCONNECTRAPID SHUTDOWN FORSOLAR PV SYSTEMMAIN PHOTOVOLTAICSYSTEM DISCONNECTMAIN SERVICEPANELRAPID SHUT DOWN DEVICEWARNINGMULTIPLE POWER SOURCESOURCES: UTILITY GRID, PV AND ESS SYSTEMLABEL LOCATION: MAIN SERVICE DISCONNECT, PRODUCTION/NET METERPER CODE: NEC 690.59, 705.12(C)!W 5TH ST W 4TH ST IQ SYSTEMCONTROLLER 2 PV-084/1/2023SHEET TITLEDRAWN DATEDRAWN BYPCADSHEET NUMBERSYSTEM DETAILSPHONE - (425) 610-7067REVDATEDESCRIPTIONREVISIONSDC SIZE: 14.800 KW DC-(STC)AC SIZE: 11.600 KW AC(40) SILFAB SOLAR SIL-370 HC(40) ENPHASE IQ8PLUS-72-2-US [240V]CONTRACTORPROJECT NAME & ADDRESS1706 LOMBARD AVEEVERETT, WA 98201BLOSSOM SOLARAPN #: 0630000102620000AHJ: CITY OF PORT ANGELESUTILITY: CITY OF PORT ANGELESEMIL MOILANEN809 W 5TH ST ,PORT ANGELES, WA 98363STRING DIAGRAMREFERENCE ONLY R-014/1/2023SHEET TITLEDRAWN DATEDRAWN BYPCADSHEET NUMBERSYSTEM DETAILSPHONE - (425) 610-7067REVDATEDESCRIPTIONREVISIONSDC SIZE: 14.800 KW DC-(STC)AC SIZE: 11.600 KW AC(40) SILFAB SOLAR SIL-370 HC(40) ENPHASE IQ8PLUS-72-2-US [240V]CONTRACTORPROJECT NAME & ADDRESS1706 LOMBARD AVEEVERETT, WA 98201BLOSSOM SOLARAPN #: 0630000102620000AHJ: CITY OF PORT ANGELESUTILITY: CITY OF PORT ANGELESEMIL MOILANEN809 W 5TH ST ,PORT ANGELES, WA 98363RESOURCEDOCUMENT R-024/1/2023SHEET TITLEDRAWN DATEDRAWN BYPCADSHEET NUMBERSYSTEM DETAILSPHONE - (425) 610-7067REVDATEDESCRIPTIONREVISIONSDC SIZE: 14.800 KW DC-(STC)AC SIZE: 11.600 KW AC(40) SILFAB SOLAR SIL-370 HC(40) ENPHASE IQ8PLUS-72-2-US [240V]CONTRACTORPROJECT NAME & ADDRESS1706 LOMBARD AVEEVERETT, WA 98201BLOSSOM SOLARAPN #: 0630000102620000AHJ: CITY OF PORT ANGELESUTILITY: CITY OF PORT ANGELESEMIL MOILANEN809 W 5TH ST ,PORT ANGELES, WA 98363RESOURCEDOCUMENT R-034/1/2023SHEET TITLEDRAWN DATEDRAWN BYPCADSHEET NUMBERSYSTEM DETAILSPHONE - (425) 610-7067REVDATEDESCRIPTIONREVISIONSDC SIZE: 14.800 KW DC-(STC)AC SIZE: 11.600 KW AC(40) SILFAB SOLAR SIL-370 HC(40) ENPHASE IQ8PLUS-72-2-US [240V]CONTRACTORPROJECT NAME & ADDRESS1706 LOMBARD AVEEVERETT, WA 98201BLOSSOM SOLARAPN #: 0630000102620000AHJ: CITY OF PORT ANGELESUTILITY: CITY OF PORT ANGELESEMIL MOILANEN809 W 5TH ST ,PORT ANGELES, WA 98363RESOURCEDOCUMENT R-044/1/2023SHEET TITLEDRAWN DATEDRAWN BYPCADSHEET NUMBERSYSTEM DETAILSPHONE - (425) 610-7067REVDATEDESCRIPTIONREVISIONSDC SIZE: 14.800 KW DC-(STC)AC SIZE: 11.600 KW AC(40) SILFAB SOLAR SIL-370 HC(40) ENPHASE IQ8PLUS-72-2-US [240V]CONTRACTORPROJECT NAME & ADDRESS1706 LOMBARD AVEEVERETT, WA 98201BLOSSOM SOLARAPN #: 0630000102620000AHJ: CITY OF PORT ANGELESUTILITY: CITY OF PORT ANGELESEMIL MOILANEN809 W 5TH ST ,PORT ANGELES, WA 98363RESOURCEDOCUMENT R-054/1/2023SHEET TITLEDRAWN DATEDRAWN BYPCADSHEET NUMBERSYSTEM DETAILSPHONE - (425) 610-7067REVDATEDESCRIPTIONREVISIONSDC SIZE: 14.800 KW DC-(STC)AC SIZE: 11.600 KW AC(40) SILFAB SOLAR SIL-370 HC(40) ENPHASE IQ8PLUS-72-2-US [240V]CONTRACTORPROJECT NAME & ADDRESS1706 LOMBARD AVEEVERETT, WA 98201BLOSSOM SOLARAPN #: 0630000102620000AHJ: CITY OF PORT ANGELESUTILITY: CITY OF PORT ANGELESEMIL MOILANEN809 W 5TH ST ,PORT ANGELES, WA 98363RESOURCEDOCUMENT R-064/1/2023SHEET TITLEDRAWN DATEDRAWN BYPCADSHEET NUMBERSYSTEM DETAILSPHONE - (425) 610-7067REVDATEDESCRIPTIONREVISIONSDC SIZE: 14.800 KW DC-(STC)AC SIZE: 11.600 KW AC(40) SILFAB SOLAR SIL-370 HC(40) ENPHASE IQ8PLUS-72-2-US [240V]CONTRACTORPROJECT NAME & ADDRESS1706 LOMBARD AVEEVERETT, WA 98201BLOSSOM SOLARAPN #: 0630000102620000AHJ: CITY OF PORT ANGELESUTILITY: CITY OF PORT ANGELESEMIL MOILANEN809 W 5TH ST ,PORT ANGELES, WA 98363RESOURCEDOCUMENT R-074/1/2023SHEET TITLEDRAWN DATEDRAWN BYPCADSHEET NUMBERSYSTEM DETAILSPHONE - (425) 610-7067REVDATEDESCRIPTIONREVISIONSDC SIZE: 14.800 KW DC-(STC)AC SIZE: 11.600 KW AC(40) SILFAB SOLAR SIL-370 HC(40) ENPHASE IQ8PLUS-72-2-US [240V]CONTRACTORPROJECT NAME & ADDRESS1706 LOMBARD AVEEVERETT, WA 98201BLOSSOM SOLARAPN #: 0630000102620000AHJ: CITY OF PORT ANGELESUTILITY: CITY OF PORT ANGELESEMIL MOILANEN809 W 5TH ST ,PORT ANGELES, WA 98363RESOURCEDOCUMENT R-084/1/2023SHEET TITLEDRAWN DATEDRAWN BYPCADSHEET NUMBERSYSTEM DETAILSPHONE - (425) 610-7067REVDATEDESCRIPTIONREVISIONSDC SIZE: 14.800 KW DC-(STC)AC SIZE: 11.600 KW AC(40) SILFAB SOLAR SIL-370 HC(40) ENPHASE IQ8PLUS-72-2-US [240V]CONTRACTORPROJECT NAME & ADDRESS1706 LOMBARD AVEEVERETT, WA 98201BLOSSOM SOLARAPN #: 0630000102620000AHJ: CITY OF PORT ANGELESUTILITY: CITY OF PORT ANGELESEMIL MOILANEN809 W 5TH ST ,PORT ANGELES, WA 98363RESOURCEDOCUMENT R-094/1/2023SHEET TITLEDRAWN DATEDRAWN BYPCADSHEET NUMBERSYSTEM DETAILSPHONE - (425) 610-7067REVDATEDESCRIPTIONREVISIONSDC SIZE: 14.800 KW DC-(STC)AC SIZE: 11.600 KW AC(40) SILFAB SOLAR SIL-370 HC(40) ENPHASE IQ8PLUS-72-2-US [240V]CONTRACTORPROJECT NAME & ADDRESS1706 LOMBARD AVEEVERETT, WA 98201BLOSSOM SOLARAPN #: 0630000102620000AHJ: CITY OF PORT ANGELESUTILITY: CITY OF PORT ANGELESEMIL MOILANEN809 W 5TH ST ,PORT ANGELES, WA 98363RESOURCEDOCUMENT R-104/1/2023SHEET TITLEDRAWN DATEDRAWN BYPCADSHEET NUMBERSYSTEM DETAILSPHONE - (425) 610-7067REVDATEDESCRIPTIONREVISIONSDC SIZE: 14.800 KW DC-(STC)AC SIZE: 11.600 KW AC(40) SILFAB SOLAR SIL-370 HC(40) ENPHASE IQ8PLUS-72-2-US [240V]CONTRACTORPROJECT NAME & ADDRESS1706 LOMBARD AVEEVERETT, WA 98201BLOSSOM SOLARAPN #: 0630000102620000AHJ: CITY OF PORT ANGELESUTILITY: CITY OF PORT ANGELESEMIL MOILANEN809 W 5TH ST ,PORT ANGELES, WA 98363RESOURCEDOCUMENT R-114/1/2023SHEET TITLEDRAWN DATEDRAWN BYPCADSHEET NUMBERSYSTEM DETAILSPHONE - (425) 610-7067REVDATEDESCRIPTIONREVISIONSDC SIZE: 14.800 KW DC-(STC)AC SIZE: 11.600 KW AC(40) SILFAB SOLAR SIL-370 HC(40) ENPHASE IQ8PLUS-72-2-US [240V]CONTRACTORPROJECT NAME & ADDRESS1706 LOMBARD AVEEVERETT, WA 98201BLOSSOM SOLARAPN #: 0630000102620000AHJ: CITY OF PORT ANGELESUTILITY: CITY OF PORT ANGELESEMIL MOILANEN809 W 5TH ST ,PORT ANGELES, WA 98363RESOURCEDOCUMENT R-124/1/2023SHEET TITLEDRAWN DATEDRAWN BYPCADSHEET NUMBERSYSTEM DETAILSPHONE - (425) 610-7067REVDATEDESCRIPTIONREVISIONSDC SIZE: 14.800 KW DC-(STC)AC SIZE: 11.600 KW AC(40) SILFAB SOLAR SIL-370 HC(40) ENPHASE IQ8PLUS-72-2-US [240V]CONTRACTORPROJECT NAME & ADDRESS1706 LOMBARD AVEEVERETT, WA 98201BLOSSOM SOLARAPN #: 0630000102620000AHJ: CITY OF PORT ANGELESUTILITY: CITY OF PORT ANGELESEMIL MOILANEN809 W 5TH ST ,PORT ANGELES, WA 98363RESOURCEDOCUMENT R-134/1/2023SHEET TITLEDRAWN DATEDRAWN BYPCADSHEET NUMBERSYSTEM DETAILSPHONE - (425) 610-7067REVDATEDESCRIPTIONREVISIONSDC SIZE: 14.800 KW DC-(STC)AC SIZE: 11.600 KW AC(40) SILFAB SOLAR SIL-370 HC(40) ENPHASE IQ8PLUS-72-2-US [240V]CONTRACTORPROJECT NAME & ADDRESS1706 LOMBARD AVEEVERETT, WA 98201BLOSSOM SOLARAPN #: 0630000102620000AHJ: CITY OF PORT ANGELESUTILITY: CITY OF PORT ANGELESEMIL MOILANEN809 W 5TH ST ,PORT ANGELES, WA 98363RESOURCEDOCUMENT R-144/1/2023SHEET TITLEDRAWN DATEDRAWN BYPCADSHEET NUMBERSYSTEM DETAILSPHONE - (425) 610-7067REVDATEDESCRIPTIONREVISIONSDC SIZE: 14.800 KW DC-(STC)AC SIZE: 11.600 KW AC(40) SILFAB SOLAR SIL-370 HC(40) ENPHASE IQ8PLUS-72-2-US [240V]CONTRACTORPROJECT NAME & ADDRESS1706 LOMBARD AVEEVERETT, WA 98201BLOSSOM SOLARAPN #: 0630000102620000AHJ: CITY OF PORT ANGELESUTILITY: CITY OF PORT ANGELESEMIL MOILANEN809 W 5TH ST ,PORT ANGELES, WA 98363RESOURCEDOCUMENT R-154/1/2023SHEET TITLEDRAWN DATEDRAWN BYPCADSHEET NUMBERSYSTEM DETAILSPHONE - (425) 610-7067REVDATEDESCRIPTIONREVISIONSDC SIZE: 14.800 KW DC-(STC)AC SIZE: 11.600 KW AC(40) SILFAB SOLAR SIL-370 HC(40) ENPHASE IQ8PLUS-72-2-US [240V]CONTRACTORPROJECT NAME & ADDRESS1706 LOMBARD AVEEVERETT, WA 98201BLOSSOM SOLARAPN #: 0630000102620000AHJ: CITY OF PORT ANGELESUTILITY: CITY OF PORT ANGELESEMIL MOILANEN809 W 5TH ST ,PORT ANGELES, WA 98363RESOURCEDOCUMENT ELECTRICAL INSPECTION WIRING REPORT APPROVED NOT APPROVED DITCH ROUGH IN/COVER SERVICE FINAL COMMENTS 1. Label new circuit in directory. NEC 408.4 2. Equipment grounding conductor required for back-up load panel circuits. NEC 250-109 3. I need the installer to meet me for the next inspection. NOTIFY INSPECTOR at (360) 808-2613 WHEN CORRECTIONS ARE COMPLETED WITHIN 15 DAYS DATE PERMIT # INSPECTOR 6/5/2023 23-546 TAP OWNER CONTRACTOR Blossom Solar PROJECT ADDRESS 809 W 5th St ELECTRICAL INSPECTION WIRING REPORT APPROVED NOT APPROVED DITCH ROUGH IN/COVER SERVICE FINAL COMMENTS NOTIFY INSPECTOR at (360) 808-2613 WHEN CORRECTIONS ARE COMPLETED WITHIN 15 DAYS DATE PERMIT # INSPECTOR 6/21/2023 23-546 TAP OWNER CONTRACTOR Blossom Solar PROJECT ADDRESS 809 W 5th St