Loading...
HomeMy WebLinkAbout2532 W 16th St - Buildinge P O T AV a 1211A1 U T F N Nkic,,,c0 Application Number 04- 00000052 Date 3/10/04 Pin number 781164 Property Address 2532 W 16TH ST ASSESSOR PARCEL NUMBER 06 30 -00 4 4 0050 0000 Application description RES MANUFACTURED HOME Subdivision Name 41 16 Property Use Property Zoning RS9 RESDNTL SINGLE FAMILY 4 r Application valuation 64600 Owner GERALD MORRIS /MARILYN DAVIS 1009 S LAUREL STREET PORT ANGELES WA 98362 Other Fees T \PLANNING\FORI4s 1 :102:1 [11/14/2003] CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING DIVISION 321 EAST 5TH STREET PORT ANGELES, WA 98362 Contractor OWNER Structure Information NEW 1280 SF MAN W /ATTACHED GARAGE Construction Type TYPE V NON RATED Occupancy Type SINGLE FAM CONGREGATES Other struct info TOTAL LOT COVERAGE 19 00 EXISTING LOT COVERAGE 1 00 LOT SIZE 9075 00 PROPOSED LOT COVERAGE 1760 00 TOTAL LOT COVERAGE 1760 00 NUMBER OF UNITS 1 00 Permit ELECTRICAL NEW RESIDENTIAL Additional desc MOBILE HOME Sub Contractor QUALITY ELECTRIC Permit Fee 76 30 Plan Check Fee 00 Issue -Date 3/10/04 Valuation 0 Expiration Date 9/06/04 Qty Unit Charge Per 1 00 76 3000 ECH EL -MANF HOME SERVICE FEEDER Special Notes and Comments Address numbers shall be plainly visible from the street Address numbers shall be a minimum of six inches high and be in contrast in color of there background A residential fire sprinkler system shall be installed per NFPA 13D will be required 2nd option is to install an out side alarm bell that is eletronicly connected to the residence s smoke detectors The alarm bell will be painted red in color and identified as Fire alarm Electrical load calculations and elctrical permits are required SEWER SYSTEM DELV CHARGE STATE SURCHARGE PW WATER SYSTEM USE FEE Extension 76 30 745 00 4 50 1025 00 Fee summary Charged Paid Credited Due Permit Fee Total 76 30 76 30 00 00 Plan Check Total 00 00 00 00 Other Fee Total 1774 50 1774 50 00 00 Grand Total 1850 80 1850 80 00 00 Separate Permits are required for electrical work, SEPA, Shoreline ESA, utilities private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last inspection I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Signature`of Contractor or Authorized Agent Date Signature of Owner (if owner is builder) Date c-,: CALL 417 -4815 FOR BUILDING INSPECTIONS. CALL 417 -4735 FOR ELECTRICAL INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE. INSPECTION TYPE FOUNDATION: FOOTINGS WALLS I FOUNDATION DRAINAGE /DOWN SPOUTS I I I ELECTRICAL (LIGHT DEPT) SEPARATE PERMIT ROUGH -IN I I I PLUMBING UNDER FLOOR SLAB ROUGH -IN I WATER LINE (METER TO BLDG) I GAS LINE I I BACK FLOW WATER I I AIR SEAL WALLS I CEILING I I I I FRAMING JOISTS GIRDERS I SHEAR WALL/HOLD DOWNS I WALLS ROOF CEILING I I I DRYWALL (INTERIOR BRACED PANEL ONLY) I I I T -BAR I I I INSULATION SLAB I I WALL FLOOR CEILING I I I I MECHANICAL HEAT PUMP I GAS LINE I I I WOOD STOVE PELLET CHIMNEY I I I HOOD DUCTS I I I I PW UTILITIES SITE WORK (Engineering Division) SEPARATE PERMIT 4's: WATERLINE METER I SEWER CONNECTION I SANITARY STORM I I I PLANNING DEPT SEPARATE PERMIT #'s PARKING/LIGHTING I I I LANDSCAPING I I I RESIDENTIAL ELECTRICAL LIGHT DEPT CONSTRUCTION R.W PW/ ENGINEERING 417 -4807 FIRE 417 -4653 PLANNING DEPT 417 -4750 I BUILDING 417 -4815 I T\PLANNING\FORMS \1102.15 [11/14/2003) BUILDING PERMIT INSPECTION RECORD DATE ACCEPTED YES I NO SEPA. ESA. SHORELINE. COMMENTS FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE DATE YES NO COMMERCIAL DATE ACCEPTED YES I NO 417 -4735 ELECTRICAL LIGHT DEPT CONSTRUCTION R.W PW ENGINEERING I FIRE DEPT I PLANNING DEPT I BUILDING I I I I I I I I I a -NO r CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING DIVISION 321 EAST 5TH STREET PORT ANGELES, WA 98362 Application Number 04 00000052 Pin number 781164 Page 2 Date 3/10/04 Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days if construction or work is suspended or abandoned for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last inspection I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Signature of Contractor or Authorized Agent Date Signature of Owner (if owner is builder) Date T•\PLANNING\FORMS \1102.15 [11/14/2003] ELECTRICAL LIGHT DEPT 417 -4735 BUILDING PERMIT INSPECTION RECORD CALL 417 -4815 FOR BUILDING INSPECTIONS. CALL 417 -4735 FOR ELECTRICAL INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE. INSPECTION TYPE DATE ACCEPTED COMMENTS YES NO FOUNDATION: FOOTINGS WALLS FOUNDATION DRAINAGE /DOWN SPOUTS ELECTRICAL (LIGHT DEPT) SEPARATE PERMIT ROUGH -IN PLUMBING UNDERFLOOR /SLAB ROUGH -IN WATER LINE (METER TO BLDG) GAS LINE BACK FLOW WATER AIR SEAL WALLS CEILING FRAMING JOISTS GIRDERS SHEAR WALL/HOLD DOWNS WALLS ROOF CEILING DRYWALL (INTERIOR BRACED PANEL ONLY) T -BAR INSULATION SLAB WALL FLOOR CEILING MECHANICAL HEAT PUMP GAS LINE WOOD STOVE PELLET CHIMNEY HOOD /DUCTS PW UTILITIES SITE WORK (Engineering Division) SEPARATE PERMIT #'s: WATERLINE METER SEWER CONNECTION SANITARY STORM PLANNING DEPT SEPARATE PERMIT #'s SEPA. PARKING/LIGHTING ESA. LANDSCAPING SHORELINE. FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED YES I NO CONSTRUCTION R.W PW/ ENGINEERING 417 -4807 FIRE 417 -4653 I PLANNING DEPT 417 -4750 I BUILDING 417 -4815 I T \PLANNING\FORMS \1102.15 [11/14/2003] ,fig L160. I ELECTRICAL LIGHT DEPT CONSTRUCTION R.W PW ENGINEERING I FIRE DEPT I PLANNING DEPT I BUILDING ~ ..........- . . . . CITY OF PORT ANGELES . . DEPARTMENT OF COMMUNITY DEVELOPMENT - BUTI...DING DIVISION 321 EAST 51H STREET,"PORT ANGELES, W A 98362 95.00 1/27/04 7/25/04 Plan Check Fee . Valuation . . . .00 64600 ;~:'" ' ^');- :".G.0,~1:(;'}~'i:" <.1 ".;', Application Number Property.Address . ASSBSSORPARCELNUMBER: ..Application description ... ~pbdivision Name 'ProJ;lerty Use . . . . 'Property Zoning . .. ~plication valuation 04-00000052 Date 1/27/04 2532 W16TH ST 06-30-00~4~4-0050-0000- RES MANUFACTURED HOME RS9 RBSDNTL SINGLE FAMILY 64600 Contractor GBRALD.MORRIS/MARILYN DAVIS 1009 S'LAORBL STREET PORT ANGBLES WA 98362 ;;I!-';'--M-.-c.:--c;~, -..,_':_~:Structure Information Construction. Type '. . Occupancy Type . . . Otherstruct info. . . . NEW 1280 SF MAN W/ATTACHED GARAGB TYPB V NON-RATED SINGLE FAM & CONGREGATES TOTAL Ik LOT. COVERAGB EXISTING LOT CovERAGB LOT SIZE PROPOSED LOT COVERAGB TOTAL LOT COVERAGB NUMBBR OF UNITS 19.00 1.00 9075.00 1760.00 1760.00 1.00 ------~-----------------------~------------~-------------------------------~ Permit . . . . .' Additionai desc Permit Fee '. . Issue nate EXpiration Date BUILDING PERMIT -RESIDENTIAL 480SF ATTACHED GARAGB 204.75 Plan Check Fee . 1/27/04 Valuation .. 7/25/04 81.90 9600 WE FEE 8.00 14.0000 THOU BL-2001-2SK (14 PER K) Qty Unit CharsJe Per Extension 92.75 112.00 --~---------------------------------------~-_._-----~-------.-,~-------------- Permit . . . . Additional desc p~rmit Fee Issue Date ~~fationDate PUBLIC WORKS RES WATER SERV DROP IN WATER METER 150.00 Plan Check Fee 1/27/04 . Valuation . . 7/25/04 .00 64600 -......._,..;;.... c.:;:?J~~y unit Charge Per Extension. 150.00 :'. C0~ r:; BASE FEE .' . - - -.- - -:"'J"'l;~.7"~ ,~\.---- -- - - - - - - - ~ - - -- - - - - - - - - - - - - - - - - - - - - - -- - - - - - -... - - - --......... -... - -'- - ~ -- Permit ... . RIGHT OF WAY ,~.__Additi9naldesc Permit Fee i:ssu~Date EXpifa:tion nate 45.00 1/27/04 7/25/04 Plan Check Fee . Valuation . .00 64600 Qty Unit Charge Per 1.00 45.0000 ECH RIGHT OF WAY PBRMIT Extension 45.00 ------~~~~~---~-~-.------~-------~~_..._-------~-~'----~~~~--------------~-----~ Permit . . . . _ . _.. .,Additional desc Permit Fee Issue Date 'EXpiration Date SANITARY SBWBR BOOK UP Separat~f'. . m,ltsaRtreqUlrefor efebbical work, SEPA, Shoreltne. ESA, utilities,1fJffiP.ROWRI public improvements.' This pel1l1lt.~comes nullan(j.vqldjf.wor:kor construction authorized is notcommencedwithin1.80days, if construction or work Issuspendedo~a~iri~oned fora period of180 days after the work as commenced, or if requiredlrispections havenot been requested within 180 days from.thEfl.ast inspectio.n~J hereby certify that I have read and examined tI:lis application and know the same to be true and correct. AHprov!Sionspf laws and ordinances governing thistype.of work will be complied with whether specified herein or not. The granting of a permitdoesp~t presumE;t.tqgive authority to violate or cancel the provisions of any state or local law regulating construction or the performance (If conskUOQon. . . ~aht()f7J1{~. .. Date Signature 6fOWner (ffowner is builder) . T:'l'I..ANN'IN~RMS\1I02.1S [1111412003] P8'~,~'. -. ,V~.\:::~":. ' . .:,~\-.~_. -:." .::'~L~j'r~" BUILDING PERMIT INSPECfiON RECORD CALL4 I 7-48 IS FOR BUILDING INSPECTIONS. CALL 4 I 7-4735 FOR ELECTRICAL INSPECfIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE; "IT IS UNLAWFUL TO COVER,IIVSupATE ORqONCEALANY WOo INSPECTEDAjVD ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION. .0 , \,.. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE. ......... ..... .... INSPECTION TYPE DA.TE ACCEPTED .... . COMMENTS . , .' YEs I NO '.' . FOUNDATION: . . ........< I FOOTIJIlGS ...... I WALLS ,.... <~ .' FOUNDATION DRAINAGEIOOWN Spours . ELECTRICAL (UGHT DEPT) SEPARATE PERMIT: t# . .... ,:" [e. ROUGH-IN l , . .' - '0 J .' .( .."Di....... t' '. .' PLUMBING "', .:. ".... UNDER FLOOR I SLAB ... ROUGH-IN I WATER LINE (METER TO BLDG) . GAS LINE BACK FLOW I WATER '. .. AIR SEAL .... WALLS .. I , CEILING , .. FRAMING ,. . Jr, ..' , JOISTS/.GIRDERS SHEAR W ALLIHOLD DOWNS . WALLS I ROOF I CEILING .... DRYWALL (INTERIOR BRACED PANEL ONLY) T-BAR . INSULATION SLAB WALL I FLOOR I CEILING . . I . MECHANICAL . HEAT PUMP GAS UNE WOOD STOVE I PELLET I CHIMNEY HOOD I DUCTS PW UTILITIES I SITE WORK. (Engineering Division) SEPARATE PERMIT.#'s: W ATERLINEI ~TER I.... SEWER CONNECTION . ., SANITARY . STORM . PLANNING DEPT. SEPARATEPERMITtI's SEPA: PARKINGlLIGHTlNG . ESA: . . ~DSC.~PING ....... " St!()~: ...... ' " .. ,,' ,,",, ','; ..... " ,. ;7" : . " ',. '. FlNAli INSPECTIONS REQUIRED PRIOR TO OCCUPANcYtuSE .,. . . ;I- ;; '. RESIDENTIAL n.' '" DATE .' YES NO COMMERCIA.L DATE." ACCEl"rED . '/1 YES. ."NO ~, '. .... , ELECTRICAL - UGHT DEPT. 417-4735 I' ELECTRICAL " UGHT DEPT CONSTRUCTION R. W; I PWI CONSTRUCTION - R. W. ENGINEERING 417-4807 PW I ENGINEERING FIRE 417-4653 , FIRE DEPT. " : " ~LANNING DEPT. .. 417-4750 PLANNING DEPT. . BUILDING .' :417-4815 BUILDING ' .. T:\PLANNING\FORMS\II02.15 [II/14IlOO3] j.:;' ...CITY qF PORT ANGELES DEPARTMENT OF coMMUNITY DEVELOPMENT -'BUlliDINGDIVISION 321 EAST 51H STREET,PORT ANGELES, W A 98362 Separate P~rmltsare required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. Thispe.-mltbecomes nullllnd void. if work orconstructlon authorized is not commenced within 180 days,. if construction or work Is sus~nded or1lbandoned for a p~iiodof180days after the work as commenced, or if required Inspections have not been requested within180daysf@lTl.the.last Insp~ctlon. J here~y certify that I have read. and examinedthisapplication and know the same to be true and . correct,A1IPr:6yi~i~ns(>f laws and ordinances govemingthls type of work will be complied with whether specified herein or not. The grantirigof a perrriitdOesnot presum~"togiveauthority to violate or cancel the provisions of any state or local law regulating construction or theperf()rmanceof constructlOrl," . ::;'.:~:::;.~: tl4-00000052 Page . 2 Date 1/27/04 unit Charge Per 95.0000 SA SANSEWBR HOOKUP Extension 95.00 ~~~.~-~~-~~~--~-----~-----~-------~-------~._~~~~--~--~~--~~-----------~----- . . . Permit . . . . Additional desc Pem1tFee Issue Date Expiration Date . BL . MANUFACTURED HOME HOMBS NORTHWEST MOD#48724 230.00 Plan Check Fee. 1/27/04 Valuation 7/25/04 .00 64600 Per Extension 230.00 BASE FEE ~---~----~-~------------~-----------~---~---------~------~------------------ Special. "Notes and Comments . Addrflssnumbers shall be plainly visible from the street. Address numbers shall be a minimum of six inches high and be ill contrast in color of there background. A residential fire sprinkler system shall be installed per NFPA13D will be required. . 2nd option is to install an out side alarm bell that is elet;-onicly connected.. to the residence's smoke detectors. The alarm bell will be painted red in color ~d identified as nFire alarmn . Electrical load .calculations and elctrical permits are required. --~---~-~-----------------~~-~--~_...~--------------------.----------.-.----- Other Fees SEWER SYSTEM DEr.V CHARGE STATE SURCHARGE PW WATER SYSTEM USE FEE 745.00 4.50 1025.00 ., . . '.' ,0. . ,_ .. .. " ~ . .. Fee. summary credited Charged Paid Due ,-- - -,.....-----,----_... perinit Fee Total ~liU1~Check.Total .,pther Fee Total ;J~i;~~ Total :o'C: .,",,: .00 .00 .00 .00 .00 .00 .00 .00 '724.75 81.90 . 1774.50 2581.1~ 724.75 81.90 1774.50 . 2581.15 0~~-; Date Signature of Owner (if owner is builder) Signature of Contractor or Authorized Agent T:\PI;AJllNING\FORMS\IIQ2.IS [1111412003) f :.:~~C!";:~:';l~t~:':,":::i;~,:~;':~?,:~'" , " ' ~.:.'t~~1rr:':"i:~'~"1~':('~'''ffi}~:i~".,(i;;l;i('::'~'':\ , ,',' ::,,"'~i~i,,::,,,,,),,~~, ~:i'~,f~ ' BlJILi)ING PERMIT~SPECrlON RECORD :,:;.1 ' : /',.' ., CALL 417-4815 FOR BUILDING INSPECflONS. CALL 417-4735 FORELECfRICAL INSPECfIONS. I.", ,c' . , ','.." ' ",( ,..',.... ;,,0,' ",' '''', " ",':i,:":,>',:, PLEASE PROVIDE A MINIMUM 24H01JR;.l'IOTICE.lTIS UNLAWPut TO'COVER;'INSuy,'ff10R-CONCEAL ANY WORiBEirO~', INSPECTElfAimAPg1PTED. ' POST PllltMIT IN A: C;{)NS~IgtOUS:I.OCATION. ' ,',' , KEEPPElUJ1!r CARD ANDAPPROVEDPLANS:ATI0B:SITE .' INSPECl'ION TYPE " , ,DATE ' " A~gpnm ,'" >', COMMENTS ,". ", I - "" YES NO " " " " "" J'~~iJlHI, !J14tq:f).'~11~1 FOUNDATION: FOOTINGS ""~~', 3 -I? ,,6 f.( WALLS " , ~,A '. ' '," 'C_ ~ A12-> ~.t..(~ "FOUNDATION DRAlNAGEIDOWN SPOUTS ' , " 1.L " ELECTRICAL (LIGHTDEPT) SEPARATEPERMrr: # V ,1 I I , ROUGH-IN , , PLUl\f~ING , ";";,,' ~ :'1,' " ~,ERFLooR:1 SLAB " , , ROUGH-IN ," W A TERUNE (METER TO BLDO) , GAS'LINE , BACK FLOW I WATER : '" AIR SEAL I . WALLS CEILING " I , , " ,', " , " .: FRAMING JOISTS I GIRDERS , SHEAR WALUHOLD DOWNS IS"?'~OIJ ,J..-L. WALLS I ROOF I CEILING l~ -'tj.-(:)l-' ~l~ 1" DRYWALL (INTBRIOR )3RACED PANEL ONLY) I T-BAR " , : INSULATION " SLAB , WALL t FLOOR I CEILING I - MECHANICAL ' HEAT PUMP GAS LINE , '" , WOOD STOVE I PELLET I CHIMNEY HOOD I DUCTS "" PW UTILmES1 SITE WORK (Engineering Division) SEPARATE PERMIT #'s: WATERLINE I METER " SEWER CONNECTION SANITARY SWRM , , , ,'" " P~~G DEPT., sEPARATE PERMIT #'5 SErA: PARKING/LIGHTlNG , ESA: LANDSCAPING> . "". , ., '," ~'1,+ \3:'1':" ,'\ ,t":,,', " ,., , ,8,HO~, " ',;, .. , .' ..... , "; " ".., ," FIl\I,AA1JltlSI',EqTI()~s,RE9UIRED PRIOR. TO,~C~~CYLUSEJ\~iii';!,i';\':' '" ::, ',: -, ,,:;'; -c__:" ....... I", " RESIDEN'I'IAi. ,,,-\c "DATE, ';'.'.' YES NO " 1 :.' '.' cOMMEIlCIA'l::" DATE ';\ 'AC(!~D I.... ~: '.' I,,':;, " . ";','; , .";iB, '" I.~,r:, YES .' I'NO ELECTRICAL - LifuIT DEPT. 417-:4735.: , , ELECtRICAL , YGHTDEIT " CONSTRUCTION R. W.I PWI t,... ~f)lJ ~F. CONsnWcnON,~R. W. ENGINEERING 417-4807 'PW!:~qINEERlNG FIRE 417-4653 ','" " ,'.. '.' ""'~""'-'-~"'" '.' , FIRE DEPT. .. \! ,) ., ,'e"", PLANNING DEn 417-:4750 PL~GDEPT. .. BUILDING 417-4815 BUILDING ;., P > ~'~"""~'t ;'~;L~~~~~_~__ T:\PLANNlNG\FORMS\1 102.15 [1111412003] PREPARED 6/15/04. 13:26:29 CITY OF PORT ANGELES ADDRESS CONTRACTOR OWNER PARCEL . . APPL NUMBER: 2532 W 16TH ST INSPECTION TICKET INSPECTOR JAMES L LIERLY PAGE DATE GERALD MORRIS/MARILYN DAVIS 06-30-00-4-4-0050-0000- 04-00000052 RES MANUFACTURED HOME SUBDIV: PHONE PHONE : PERMIT: BLM 00 BL MANUFACTURED HOME REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BLM 2/19/04 2/20/04 3/17/04 3/17/04 4/08/04 ~~ 01 JLL AP JLL AP JLL BLBT 01 BLM 02 BL99 01 BUILDING FOUNDATION MONO SLAB JIM 808-3281 MANUFACTURED HOME BUILDING BLOCK AND TIEDOWNS KEITH 461-1999 BUILDING FOUNDATION MONO SLAB this slab is for garage /jll BUILDING FINAL JIM 417-4737 SLAB 4 6/15/04 CONTINUED ONTO NEXT PAGE ----------------------------------- PREPARED 6/15/04, 13:26:29 CITY OF PORT ANGELES ADDRESS CONTRACTOR OWNER PARCEL . . APPL NUMBER: 2532 W 16TH ST INSPECTION TICKET INSPECTOR JAMES L LIERLY GERALD MORRIS/MARILYN DAVIS 06-30-00-4-4-0050-0000- 04-00000052 RES MANUFACTURED HOME PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL9 01 5/07/04 JLL 5/07/04 AP BL3 01 6/07/04 JLL 6/07/04 AP BL99 01 ~ JLL ~ BUILDING SHEARWALL JIM 808-3281 BUILDING FRAMING JIM 477-1737 BUILDING FINAL JIM 417-4737 PAGE DATE SOODIV: PHONE PHONE : 5 6/15/04 COMMENTS AND NOTES -------------------------------------- PREPARED 6/07/04, 12:41:28 CITY OF PORT ANGELES 2532 W 16TH ST INSPECTION TICKET INSPECTOR JAMES L LIERLY PAGE DATE ADDRESS CONTRACTOR OWNER PARCEL . . APPL NUMBER: GERALD MORRIS/MARILYN DAVIS 06-30-00-4-4-0050-0000- 04-00000052 RES MANUFACTURED HOME PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL9 01 5/07/04 JLL BUILDING SHEARWALL 5/07/04 AP JIM 808-3281 ~:~__::____~\~)~~_~__::~:~~N::::::::~AND SUBDIV: PHONE PHONE : 4 6/07/04 NOTES -------------------------------------- \ EOR OFFICIAL USE ONLY: BUILDING PERMIT - APPLICATION ~f>~\i~... ~teRec.: 12--/2.-63 c-o~,\""f, " permit#:~ Fill out COMPLETELY and in INK. Your application and site plan MUS~ BE Date Approve . '0 COMPLETE to be accepted for review: Uyou have any questions, call (360) 417-4815 Date Issued: " Q., , Applicant or Agent: ~~ft;f1J:;;::~~/~; Owner: Cfii2A L-/l It (l w::.s Address: City: Zip: Architect/Engineer: Phone: Contractor/"lfC ~A.t~~..J"NState License #:JII~A&-~xp:IO/ ()l~- , " I Address: CIS'" -S/V ? W.' City: S~ ~....v1 PROJECT ADDRESS: '2...5.52 \Iv \ to ...,. \..t ~ Block: Phone: t:83- ~v-?/ Zip: 9~3e2 ( ZONING: ~ . \- "Subdivision:;" l!j/.es.~d.' r ..l.L Db~OCXJ4'1(JoS~ LEGAL DESCRIPTION: Lot: CLALLAM COUNTY PARCEL NUMBER: Credit Card Holder Name: Billing Address: City: Credit CardType VISA MC # Exp. Date: TYPE OF WORK: SIZEN ALUATION: _ ~ )(Residential 0 NewConstr. 0 Re-roof 0 Stove Ij:O SF.@$.....s.~8 ~/SF.=$~S...:>oqO ~ o Multi-family 0 Addition 0 Move . Garage _80 SF. @ $ .x; cp ISF. = $ t (;-0 " o Commercial 0 Remodel 0 Demolition 0 Deck SF. @ $ ISF. = $_ '_ ~ o Repair 0 Sign 0 Other TOTAL VALUATION $--..Gf GO () ;;0..--' BRIEF DESCRIPTION OF THE PROJECT: lv/5.cA..I ~A,uU~Ae7?//2.4C/J .~~.!!! ~77.,L A-r:7J ~4 (;A72--~// Htt>"1- " COMMERCIALIRESIDENTIAL: Occupancy Group: . Occupant Load: Construction Type: . No. of Stories: ---1- Lot Size: 9" 7 S- Existing Sq. Ft. ," 0 & Proposed Sq. Ft. /7~ = TOTAL Sq.Ft. J?e-.O Existing lot coverage~ % & Proposed lot coverage ~% = Total lot coverage / r % APPROVALS: PLAN: BLDG: DPWU: FIRE: OTHER:_ PLANNING USE ONLY: ESAlWetland(s): 0 Yes 0 No SEPA Checklist required? 0 Yes 0 No Other: BUILDING PERMIT APPLICATION SUBMITTAL: The Building Division can provide you with information on the application and plan submittal requirements if you have questions. VALUATION OF CONSTRUCTION: In all cases, a valuation amount must be entered by the applicant. This figure Will be reviewed and may be revised by the Building Division to comply with current fee schedules. Contact the Permit Coordinator at 417 -4815 for assistance. PLAN CHECK FEE: IF a plan check fee is due it must be submitted at the time the building permit application and construction plans are submitted. All other permit fees are due atthe time of permit issuance. EXPIRATION OF PLAN REVIEW: Ifno permit is issued within 180 days of the date of application, the application will expire. The Building Official can extend the time for action by the applicant up to 180 days upon written request by the applicant (see Section 107.4 of the Uniform Building Code, current edition). No application can be extended more than once. I hereby certify that I have read and examined this application and know the same to be true and correct. I am authorized to apply for this permit and understand that it is my responsibility to determine what permits are required ,not the City's, and that I must obtain such permits prior to work. nFORMSIAPPSlB'i1di,gpemicwpd APPliC/~ ~ Date: /"2 ~//..." .' ,. &'A&vES ?A-PIC e?oT ~ S- / II..:: 10 I ~" I \' , C) ~ "\ 1- ,,'tPV \)E- ) 'JOfI'~.J v IQ _ ~o/ b_,/" x~~;~ .~ ! 't ( N co/vc,tz,..e.n::- 1f;J ,J2.otV' , II- 0 ii1!3- I I' -0 l' " ~ .. \;. ~wbr . or . ~'lE./ ~ xc. H /)12... CITY OF 'PORT ANGELES - Construction Plans The issuance of this permit based upon these' plans, specifi. catlofoS and other data shall not prevent thebuHdin~o(fi~ial' irom thereafter requiring thecorrectionol.ertor~in'~id plans, specifications and other d~ta, orfromipre~enb6g building operations being carried on Ihereundeiwhen in vIOla !ion of all codes and ordinances of risdiction. (S~'::TiON 303(c) - U form uilding Code,' \ :\pproval Date By ~., ~~_~.6IJotl. '1'1' fI~J< % . 7'f~ (... )' F.JU- wA t.? ., ,::'-:.:;;\'.,:-" . ", , ..:j3c!8?~~~~!I?~~~j~~~-f;.==~;:1 , / e X )i~; () H.;;'l;() daY;;;.' .' '. , . . . .' " ~\> .' p...,tJ. .' Y.J.... P .....;~'f';i; l./ Q E XJ 5 77 ;...t /-/-t:;M€ 1 ~o JllltJJ-- F ~tz..~ /)06f2.. ~ .. ~' /VOI2-TH- # ?F.~ ""/Ze.r,A/ 1&":::-// " ~ . / ~ :'0 I' M' > 2 ~>''-n I' ~ . 'J-:- .-' SCI oTH &- ',,1. V A- /:ZeN ~.. f< 2/. '';8'' "'::,)k~i.. . " "-i'{,-!,"::;;'-'~_f~~h i;,i:i-.;"" .-. .,-,....,;--~~: . "".~~~',:: ';<,,''1,' '~'EJ' .,~::,' :;:'," , i. '.. . .... . . .2. . II . II "f -0 ....~..... ~ ;t ( :"~:t~~,:( ".' '"~,,,. ~ .", ~.. t..".. ----. rl ,. \' .. ~'" I',,"'.", ~. . ~J. 0 . \ ~ ~\\\!, \~ tAf " 0~0 J- x4 S,r.Ilj ~ 16/0 c. tPpt# . H~.P~6 PAtVJ,~ \{ \~ Tic (JtATI ~ .2/f1- 1!)'~t2.. . ?fI/t.Ii1~"j ". p." ~/"" III 1.1 or.fft I k. .5)~ ,t, V'" Y /3-"#~" ~ ~ '.'11-" " . i " ~ in the footing and centered beneath the pier locations (See Figure 303.7); (9) A minimum of 4 inch (10 cm) nominally thick con- tinuous footings. not less than 48 inches (121 cm) wide, reinforced with approved fibers or with 10 gauge 6 inch ( 15 cm) by 6 inch (15 cm) wire fabric centered vertically within the continuous footing and no closer than I inch (3 cm) from the edge of the continuous footing. (See Fig- ure 303.8); , (I OFR'minimum 4 irich "(TO cmfilominl1lyth"icK slaD ~ -I es~.areaJhan.the.manufactured,dw.tl.lltng. and.cabam~, -;reinforcea~witn.apP'r.oveaJiberlor with 10 gauge 6 inch ( 15 cm) by 6 inch (15 cm) wire fabric c,entered vertically within the slab and no closer than I inch (3 cm) from the edge of the slab. (See Figures 303.9 and 303.10); ( 11 ) Tested and listed prefabricated footings; (12) Footings designed by an Oregon licensed professional engineer or architect and approved by the Division; or (13) Other equivalent materials approved for the intended use by the authority having jurisdiction. (b) Piers. Piers shall be placed on footings and shall not exceed the size of the footing. Piers shall be: (I) 8 inch (20 cm) by 8 inch (20 cm) by 16 inch (41 cm) concrete blocks (See Figure 303.11); d 1Il~1I .II~ :91 - ""N,MUM 256 SOUARE INCH PL YWOOO FOOTING PRESSURE TREATED ON AU SIX SIDES liOJ!; FJELD TREAn.tENT OF CUT EDGES IS NOT ACCEPTABLE Fig.ure 303.5 Single Layer 'Plywood Footing 16 ~ II~JIIVl' ~ MINIMUM 256 SQUARE INCH OOUBLE PLYWOOD FOOTING PRESSURE TREATED ON AU SIX SIDES .tIllIt; FJELD TREAn.tENT OF CUT EDGES IS NOT ACCEPTABLE Figure 303.6 Double Layer Plywood Footing so L-MIN. 2" MINIMUM I MJ(JVf. GRADE 16" MINIM M 10" so MIN, (2) CONTINUOUS #4 REBAR CONTINUOUS POURED-iN-PLACE CONCRETE FOOTING W!MiNiMUM 2500 PSi IN 28 DAYS. ,Figure 303.7 Continuous Concrete Footing . I / /. .. .. .. .. .. .. .. . . . . . . . . . . . . . :. . t . . - -,- ~ -~:~--.:.. '. ,'oJ L 48" MINIMUM liQIE; SEE TABLE 304 FOR REQUIRED PIER SPACING Figure 303.8 Continuous Concrete Footing Isometric . . "....<... '....X",.., ........X" ,," ...... ~" NOMINAl:=- II POURED-IN-PLACE'l~, ~ ;;4CONCRETE-=StAB..F.:OOT~G 250.0 ~P..SI_IN_28-DAY.S ~~ yf<' . Figure 303.9 Poured-In-Place Concrete Slab HIll] ,1 ~~'_n__. .. ..._. ~ :..u"",,- I \ ~.. d LlMINIMUM NO~AL '4" CONTINUO'US... 'CONCRETE-FOOTING 2500;';;PSI-'/C28 DAYS REINFORCED, PER SECTION 303~ OF THE-STANDARD? 10 GAUGE 6" X 6" WIRE FABRIC CENTERED VERTlge.LLY_If':L~.LAB OR t:::::RElt\fFORCED WITf;j~ ~~PROVED FIBER_eER:t &SECTION '303....eF-THElI l~J8NDARD- ---- 17 . . ."'<~.;' Figure 303.10 Poured-In-Place Concrete Slab Isometric ~ (2) Tested and listed prefabricated piers (See;Figure 303.12); (3) Designed by an Oregon licensed professional engi- neer or architect and approved by the Division; or (4) Of other equivalent materials approved for the intended use by the authority having jurisdiction. Exception: Concrete pier blocks may have wood placed between each block to absorb shock if the wood is equal in area to the block and is one of the approved materials identified in Section 303(c)(2). (3) and (4) of this standard. (c) Pier Caps. Each concrete pier shall be capped with a pier cap equal in area to the pier blocking (i.e., 8 inches (20 cm) x 16 inches (41 cm) or 16 inches (4i cm) x 16 inches (41 cm)). Pier caps shall be (See Figure 303.13): ( I ) A 4 inch (10 cm) nominally thick solid concrete block; (2) A I inch (2.5 cm) nominally thick group 2 or 3 paral- lei laminated veneer wood plate; (3) One 1-1/4 inch (3.18 cm) piece or two 3/4 inch (19 mm) pieces of plywood; (4) One 2 inch (5 cm) nominally thick Number 2 or better grade board lumber; (5) One 2 inch (5 cm) nominally thick wood polymer com- posite; 18 L \....4. NOMINAL L.. -:",POURED-IN - PLACE" CONCRETE SLAB-FOOTING -2~P"SI~IN...2B rDAYS- (6) Tested and listed prefabricated pier caps; (7) Designed by an Oregon licensed professional engi- neer or architect and approved by the Division; or (8) Of other equivalent materials approved for the intended use by the authority having jurisdiction. . Exception: Wood and wood product materials specified in Subsections (2), (3) and (4) of this section shall be pressure treated on all six sides when placed in an area subject to excess moisture (i.e. outside the underfloor enclosure or below open deck areas). (d) Pier Shims. Where shim material is used between the top of the pier cap and the bottom of the main frame. the shimming material shall not exceed 9 vertical inches (23 cm). Pier shims shall not be used with prefabricated piers unless the shims are included in and installed according to the pier's listing. Pier shims, when used. shall be one or more of the following (See Figure 303.13): (I) 2 inch (5 em) nominally thick solid concrete block equal in area to the pier cap; (2) I inch (2.5 em) nominally thick group 2 or 3 parallel laminated veneer wood plate equal in area to the pier cap; (3) 3/4 inch (19 mm) or greater plywood equal in area to the pier cap; .. .- .. .. ell .. .. .. .. .. e.. .- . i" ~ DelSlgn .Loads I Wltld 15 PS~ ' Soil Be.a..-ing 1()(X) PSF \1 TIt Down Stnpt 3150 t Wo0:in8l..oad ' S eismJc Zone 4 I Tle do'.lIll Sll'-fl' ~ fMaral sp<<l:ticltion, QQ-S.781H for Type 1, CliL~ B, Gmdt I strapping and bt a.tleut 1-114" ll. ms. zinc plAted. E.art:h Auger; 2962 ~ (TeMbd to 4750., rrunimum) Crou Dri~. 1717 .. (Calculated) . r_ !;:lSWi> -Anch~ 1390~ (C~l;Ubr.cd) '~f,'el.4' M~"'" soil presl<rr i.J 1000 P SF wJhoutcuoilJ fCport I G&~eraJ Notes i , I. The charts shown nere'J\ lIt't 10r the requirld nwnber of tlC cjowOJ on the sides of the Marrufactllred HolDC. 2 Tie dowus m required at each ehassi! bea..1\, each end of each trll.tl~b~ s<<tlOn of the Ma.tluf~turtd Ho~ 31\0 can be any of th~ types shown herein. I 1 CombUutions of the differeD! cypt& of be downs ~ be used. 14.m the CYe%lt All 04Ith ;lUser cannot be inWlI.ed. d~c to UI ob&tnlc. ciao. U$e of cross drive lJl,hors Is pe~ttod. pcovidt<i 2 c.tos.~ dri't'e , anchors &re iDJ~ for et~h e.mll AUa<< that cannol be i.1lsWlod. I Ii 5, For a.llli~ down insullrions, the MM,.fl)Otu.Ied Home ehu,is members ue shown u T btCfnj for illwtrntion purpo~s only, I Cha.!w bemns can ~50 be "CO thaped Of RFC ~. 6. E.nd tic 00WnJ: C2Il ~. teared wlthm IS- of e.ither ~d. of ehusl.& b.:.ml uil &$ soown OM end \141 doW1'\ required '~G> Chassis eeam at each ",' Mum end lb.'.... I .. i 7, The &izes, types, lengths, etc. of nultrl.1& ~.11 herein are . rril'll~rim: ~er, lonier, heavier rnmrials suppli1:d by Tl~ Down EnPnoenog ma~ be ~ a: the Rme spaciux ana locations shown. 8 Alternate devices may bo 5ubstiruted with en(ine.en approvals. - .'" .. .~.. .~...~,~- ......-:~._..__..~. 1- 15-0'-\ '-.eJ'l'd ..4 ~Q.L.\I ----, \ I I \ "'." I I I j ~ II .J I State Approval ~ ENGINEERED T1E.DOWI~ ;3YSi'tN,-i I APPROVED 1 roMC1 TO :OWC1lCMllmJ IIW!QV~I does nvt IIl1i)OIIll! C' ""'~Y'l zr.; ~':'tl~>, '; dl~. ttt:l'l rt<l~I~cClenU Q~ lpjl/i,C;lc SUt: 1:-", ,....; ret"""'^"""~ ~e o! ~:~~IS ~ ~ Of H.>J1:C~ ond CQt:l/'rtJ:/~, :'.<. ,;:: -.:- . . ~. otCC'C!.SAl""ST:fo.~~..?~: b . D.\< I" Z -1. 2. . (11 (~cunttl ~---- - .lWAf<O_... ~ 11 ':i_~~.. 00 PW1.l;l~WlI ~l5 (J"2. -1. "Z. ~ ~ 'I __.__ T\ fhi' tI. rJ.0>V1" syat,,1YI m~<1t.'l tone ~"Irem.:.-..-t;-' ! ,6CtlO/"II~M.!, 9ul1~U,;.ion (,11)' i Ii Ii Jlli - ---J) nE DOWN ENGINEEf11NG 5901 Wheaton Driv", AtI~nt~. GliIorgia 30336 404'3+HOOO Fax 404,349-0401 :- ~""~'~."/ -~ · .7P . ";': ~" .5-02 04:02 PM TJT INC SALEM I' ;1\2GGHFRli 11:0\ m Don mlNELRm -"" ~ .. P.06 503 393 6134 tr~X!~~~ ~~~ ~~G\ ~" U~I / ". . ",NSTALLATION INFORMATION . I ceoncr~t8 Anchd? &..- ~,. The MIJ2 Is designed lo ba In,1allo~ Into ;1 com:re\~ lilab a\ the time lhe ooncr6lo ID D&/no Dourad. Patio Slab Anchor This anchor Is de510nod 10 be Inserted through a 3/4' holo drilled or formed Into l1n ex/sling concrete alab. · Concrete m~t be.a 2500 PSI mInimum sl:1h wIth 4" mInimum thlckneas and S/! )( 10/10 wire mesh or fiber mOih 111$111l1t~. · Concrete slab must allow 4725 Ibs of vertical tensIon on l/'lohor without nttinQ. This II!Unwi that the Qonoretll \..elol\s 150 Ibe per cu. n. · Minimum dIstance from the anchor shaft to one edge or the '$lab Is 4 In. from ano ttlge and 2 It. from any other lIdco. · Concrete must be ; 2500 FSI minimum slab with 4' minimum thickness and ala x 10/1 0 wire mesh or fiber mesh Instatred. · Concr6't'l 51ab musl allow 4725 "bE (1 vertical tenclon on lInchor wltho\..\ IIttlng. This a~umes th,lt the concrete weighs 160 Ibe pllr cu. ft. · MinImum ol5tilnce from the anchor ahaft to one edDe of the 'lab 16 4 In from O~ caae Dne! 2 1t. trr>m any other adQo. · It Initllled In n 4" slab at mln:mi/r-, dIStances from edges. an addltionJll4yer of 5/5 or 10r10 mash (s recommended. · Slab mu5t be B In. minimum thick"!!1 al location under any onc:hor to ISlIow Sin. embedmant o111nahor 'J' roc. Concrete Slab Anchor ~ ~ ~ ~ ~ l it1la anchor 15 d · After fllvl.wlng raUrlCHOn; O$toa to &no rlgnt arUI a ole In lC 3 In. holt In the .Iab whart tho DIlellor hB11d III 10 be looateo. an a)(I~\Jng cOnl;n~ICl IOI&b. · eoner.le must be II 2500 PSI minImum slilb y,iln .r mlnlmum lhlck/'lfn and s/e x 1Cl110 wir1l mash or fjt.cr lI1.titl r"'11Wa 11. . Plac, IUlDI ~pal1$lon 81DM o~gr bolllnd place Into th~ tjrUlca hole. · C9norQlo $lab mUlll allow 4725 Ibs 01 ...ortl~110t1sion on anchor wllhoul /if11J){). 'T'h" lIuvmOl rh~l 1110 cencrOID wolghs 1 ~a Ib~ per cu. It. · Pbca rho wouhor onto the oxpanslan bon " thread nut onlQ eXJlllnllim bait 11m! tighten 1Itltil mvclmum 8xpanclon of 1I1ullxpUlclon I1MVll ~. baan aohleved. · Mlnlmum d!!tanGl! from the ancl1~H shAH to OliO 0000 Of ilia 'l~b i~ .. in. from onl tdQI anQ , It. trom ani' other lldgo. · " In.Udlid In , 'I" i'_b .al mlnJmiJm elm-MOS frc m IIdges,iln DddUlon3ll.ly.r ot ale or 10/10 'rtlre me~h or nbcr mosh Is nlCDmmended. " RlImovi nul and Wil:lhgr und pIneo cnchor hand cvor exposlld bolt. · Placi W1IihQr and nul onto bon 10 :lltllch ilnthor he<ld, tlon/on nut. . . . . ~ -.'-~ ~ . ---- ~ ..t g 1..-. c . ~.--~I I j I I I . -' ~ ....... Q1/25/02 : 16 25 ... . TX/RX NO. 2045 P. 022 P.22 f.UH . . "1iiltf m......YiAI1fI R .~'y'-~i",;- "~-"";:"-",;~,,,-,,' III .... I 11'6" I '1'10" I 12'0"---;_ 4bxSev "'~ . - Kl""'" "'*'9 Room r _2 ~~ ~ ~=~ ~ ~ :s ~ :!: " "*.... ttnhlbI - - .. --------- - ---- - - - --. -- ~ ~ N J I - I Opt m ~> :'t Master Bedroom Livi1g Room Cool. . i-3 .~ I 4bx5eJV 4bxSev 4bxSev 14'e" I 21'4" I 12'0"---; 4e'0" Model: 4e124 HO MG;:. N(!)~," W e.sT i l,2eo Sq. Ft. ~ 3~ " ~a ..j :::1~~ ,~ ~ -.- PREPARED 5/07/04, 13:53:04 CITY OF PORT ANGELES INSPECTION TICKET INSPECTOR JAMES L LIERLY PAGE DATE 3 5/07/04 ADDRESS CONTRACTOR OWNER PARCEL . . APPL NUMBER: 2532 W 16TH ST SUBDIV: PHONE PHONE : GERALD MORRIS/MARILYN DAVIS 06-30-00-4-4-0050-0000- 04-00000052 RES MANUFACTURED HOME PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL9 01 ~7/ 4 ~ BUILDING SHEARWALL JIM - 808-3281 ------------------- ----- ------------ COMMENTS AND NOTES -------------------------------------- L PREPARED 4/08/04, 12:48:15 CITY OF PORT ANGELES INSPECTION TICKET INSPECTOR JAMES L LIERLY PAGE DATE 7 4/08/04 ADDRESS CONTRACTOR OWNER PARCEL . . APPL NUMBER: 2532 W 16TH ST SUBDIV: PHONE PHONE : GERALD MORRIS/MARILYN DAVIS 06-30-00-4-4-0050-0000- 04-00000052 RES MANUFACTURED HOME PERMIT: BLM 00 BL MANUFACTURRD HOME REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BLM 01 2/19/04 JLL BUILDING FOUNDATION MONO SLAB 2/20/04 AP JIM 808-3281 MANUFACTURED HOME SLAB BLBT 01 3/17/04 JLL BUILDING BLOCK AND TIEDOWNS 3/17/04 AP KEITH 461-1999 BLM 02 A4{0,!1,0-L-J. "L~ BUILDING FOUNDATION MONO SLAB ~ ~ this slab is for garage /jll -------------------------------------- COMMENTS AND NOTES -------------------------------------- .L ~ INSPECTION TICKET INSPECTOR JAMES L LIERLY PREPARED 3/15/04, 12:15:09 CITY OF PORT ANGELES ADDRESS CONTRACTOR OWNER PARCEL . . APPL NUMBER: 1028 W 16TH ST HOCH CONSTRUCTION HOCH, RICK/TERRY 06-30-00-0-4-4130-0000- 04-00000168 RES REMODEL PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS SUBDIV: PHONE (360) 452-5381 PHONE: (360) 452-5381 PAGE DATE 8 3/15/04 BL3 01 3/15/04 JLL BUILDING FRAMING ---------~--~--------- COMMENTS AND NOTES ---------------------------------_____ -- i-\~ '6Je~k.. ~ rut\- ~J-l CdL "i4 f ) .~ -e. BUILDING DIVISION CITY OF PORT ANGELES * * Correction Notice Job Located at -fU 1.- ~ ~ ~ Inspection of your work revealed that the following is not in accordance with the codes governing the work in this jurisdiction: ) F\t2-f; b~ouk,B 'PuP- VeuJJ ~~\ itJ(~ 1--\~vJ ~~ ~, These corrections must be made and are not to be covered until reinspection i~de. When corrections have been made, please call I, .... 4~ I S-- for inspection. Dale ~ ~~. ~.:..-. Inspector for Building Division DO NOT REMOVE THIS TAG PREPARED 2/19/04, 13:02:00 CITY OF PORT ANGELES INSPECTION TICKET INSPECTOR JAMES L LIERLY PAGE DATE 5 2/19/04 ADDRESS CONTRACTOR OWNER PARCEL . . APPL NUMBER: 2532 W 16TH ST SUBDIV: PHONE PHONE : GERALD MORRIS/MARILYN DAVIS 06-30-00-4-4-0050-0000- 04-00000052 RES MANUFACTURED HOME PERMIT: BLM 00 BL MANUFACTURED HOME REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BLM 01 ~19/04 JL: 11 BUILDING FOUNDATION MONO SLAB ~ JIM 808-3281 MANUFACTURED HOME SLAB ---------------- ~-------------------- COMMENTS AND NOTES -------------------------------------- PREPARED 3/17/04. 12:46:32 CITY OF PORT ANGELES INSPECTION TICKET INSPECTOR JAMES L LIERLY PAGE DATE 2 3/17/04 ADDRESS CONTRACTOR OWNER PARCEL . . APPL NUMBER: 2532 W 16TH ST SUBDIV: PHONE PHONE : GERALD MORRIS/MARILYN DAVIS 06-30-00-4-4-0050-0000- 04-00000052 RES MANUFACTURED HOME PERMIT: BLM 00 BL MANUFACTURED HOME REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BLM 01 2/19/04 JLL BUILDING FOUNDATION MONO SLAB 2/20/04 AP JIM 808-3281 MANUFACTURED HOME SLAB ~~~~_::__~__~~_____~~:~~:~::~::::S~DT:::::N:_____________________________________ t FROM KIRSCH ELECTRIC FAX NO. : 3606830869 Mar. 08 2004 09:03AM Pi .""".. "Il'" . I)' . ~', , ~LIUif ;I.M:/l ::,: ;n~ Oi :35 iM CITY OF PM BLOC DEFT ? A'! JL~.. x:J .11'/ '!J 1'"'11 ""I .."').... r;,'. '.1'_:,:'.;:)':: , [111;0 ,~ w EL..ECTRICAL PERMIT APPLICATION fOR omC!A.!.. 'JSJ; O~"l.':" Daef.t.c:. _ Pu.i\., Dlllt~C; C~lYo><I The EIQ;clt:'cal PermllAppllcalion m.us1. b!: filled mn cl.lnJDletelv PJeB!;1! fypttor reprint In Ink: Hyoo nave any que"UQIlC, pleas. cliI,ll (36(1J 411-4r.!5 Fax. nu~b8f: f36O) .417-4711 o~-sz.. O"".'.rEI.c.Con...oto,Ag.n~ Qv:) ~ P. Ie cf, F'ropo:tyOwner. j'Y7~,t..$L.._ __ C; Add....: ~+ S ~ ~ Lj".i~.s L", ~CI'" .f:. rl- aoctn..1 Con~or:a:_u~\ 11;. ? ( ~ c~, . . .. u-.. <<< Mdr...: City: P.ond:'l(' ~ - Gift<=; Fax~ Phone: Jln:J~J( S Exjo: Zip; PIiooe: Zip; Credit Can! Holder Neme: OA, ~r:rRICAL pONTRACTOR ,~.t~ . INSTAlLATION WtRm BY: 0 OWNER BIlling Adc1ress: GilT, cretfJt Card Number. Exp, DaM' Zip: VISA: Me; - - PRO.lECT ADDRess: ?- ? 3 2- t..o> , I C, t!1 ,..:5T TVP!; OF WORK: Cne~ ..lithe! apply: rN~ 0 A1teraUo!\lAddifion:: ~ Residenlial 0 Multl-famny IJ Commercial 'A Mo~ne H~me., Sq. Ft }5'00. . CJ Remote Maler 0 Detached g~e ' 0 Hot Tub O-Swlm Pool D SeptiC "'ump. 0. Low VoilBlIe. 0. Telecom, 0 Slgl Number of ercuib!l !lltded or altsr9d: . DESCRIPTION OF THE ELECTRICALPRCJECT;. /110&1L-~ ~~. e.octnc:a( Heat Load Additions and or Subtractfona o !laseto3nf. 1!/.FumeCB O_tP"",p o F:an..WaJl -~ ,Ja... ~N lRA =I<W - CJ OVerhoad Service o Temp Service . . Xunde'll,ound S.rvice 'Sl!rvJce Infonnatto'l VolIBge: I;). rf.. '-10 Phase: V:'1 0:> . ServioeS1ze:~~ Feeder S~:~." , hereby certify that I have rfJlJd and examined this application and know that same to tJt' Irve and correot, and I 8m authorized to apply forthis permit I understand it is not the Clty's legal responsibility to determine Whot permits 3re roqulred: it remains the eppliCBnts responsibility to (ermine what pe ifJJ ar9 require!! and to obtein such. jjIW. erL . .~It Card Holder.'s Signature: Owner Dr Elle. Cont. Signature: 1N.~ 3-q-o~ Date::?:. -;L -01 Data: PERMIT FEE: $ ~ 6. :s 0