Loading...
HomeMy WebLinkAbout1632 E 4th St - Building?'~%._~_ ~ CITY OF PORT ANGELES ~1 PUBLIC WORKS-BUILDING DIVISION ~ 321 EAST 5TH STREET, PORT ANGELES, WA 98362 BUILDING PERMIT ISSUED: 2/01/2001 PERMIT NO: 12464 OWNER/APPLICANT PROPERTY LOCATION 1632 4TH ST E BRAD WEATHERBEE 201 ROBINSON RD Lot: 2 Port Angeles, WA 98362 Block: 183 [] Long Legal 360/452-3710 Subdivision: TPA T: S: Parcel No: 063000018305000 CONTRACTOR ARCHITECT WEATHERBEE CONSTRUCTION N/A 386 HULSE RD Port Angeles, WA 98363 , 98360-0000 360/457-1433 360/000-0000 PROJECT INFO Project Value: $98,255.00 SFD Units: 0 Commercial: 0 '--- Project Type: SFR NEW SFD SQ FT: 0 Industrial: 0 ~ Occupancy Type: RESIDENTIAL Garage: 0 ~ MFD Units: 0 ~ Occupancy Group: Construction Type: WOODFRAME MFD SQ FT: 0 Zoning Use: RS7 PROJECT NOTES I NEW SFR 1935 SQ FT AND A 559 SQ FT ATTACHED GARAGE PLANS A-10 FEES ASSESSMENT Building Permit: $986.75 Misc Fee 1: $0.00 Plan Check: $394.70 Misc Fee 2: $0.00 State Surcharge: $4.50 Misc Fee 3: $0.00 House Moving: $0.00 Manufactured Home: $0.00 Sign: $0.00 TOTAL FEE: $1,557.85 Plumbing: $116.00 AMOUNT PAID: $1,557.85 Mechanical: $55.90 BALANCE DUE: $0.00 Radon: $0.00 Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a pedod of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of aws and ordnances govern ng th s type of work w be comp ed w th whether spec fled herein or not. The granting of a permit does not presume to give authority to viol~.te or cancel the provisions of any state or local law regulating construction or the performance of constructiqp.n. / / /,, _ IS gnature of Contractor or Author zed Agent Date Signature of Owner (if owner is builder) Date BUILDING PERMIT INSPECTION RECORD CALL 41%481 $ FOR BUILDING INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. ITIS UNL,4 WFUL TO COVER, · INSUL,4TE OR CONCEAL ANY WORg BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE I DATE IYEsACCEPTED[ NO COMMENTS FOUNDATION: FOtINDATION DRAINAGE Rouo.-rN I I ROUGH-IN WATER LINE BACK FLOW / WATER CEIkiNG JOISTS / GIRDERS SHEAR WAkL DRYWALL INSULATION I / /. HEAT PUMP WOODSTOVE / PELLET/CHIMNEY / INSERT HOOD/DUCTS ~W ETILITIES / SI'rE WORK (Engin~fing Division) $EPA~IE PERMIT ~'s: WATERLINE / METER SEWER CONNECTION LANDSCAPING SHORELINE: FINAL INSPECTIONS REQL IRED PRIOR TO OCCUPANCY/L'S~ RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTE~ YES NO ELECT~CAL - LIGHT DEPT 417-4735 ELECTRICAL CONSTRUCTION R W. / PW/ ~ ~ CONSIRUCTION - R.W, PLANNING DEPT 4174750 '//~ ~/ PLANN~G DEPT. BUILDING 417 ~,,, ~ // BUILDING ~+ VOaT ,~,._ FOR OFFICIAL USE ONLY: o~, Building/Utility/Electric/Fire Pemit App~cafion ~se fiH ~t compl~y. T~ ~ ~t in ~ If~u have qu~ons SHB1724: pl~ c~ (360) 417~81~ or F~: (360) 417~711 ~ofCo~l~, Cr~t C~ ~ .~. Date:~A MC O~WO~: SIZ~UA~ON: o EI~ ~ LP-g~ o Si~ o UST T~V~UA~ON $ ~)~,~ P~G USE O~Y: ~ROV~S: P~.~ P~ts ~r~: Not~:. BLDG Site PI~ md Use A~v~ ~: D~e: ES~md(s): a Y~ a No SEPA Christ r~r~? ~ Y~ o No ~: O~K~ P~CA~ON S~TT~: Yo~r~ika~onand~te~lanm~hefil~do~tcom~kte~tobeaece~tedfor~l~. pl~s me to be ~H~ to ~e ~l~ng Di~sion. o~ p~ f~ ~e due at ~e time ofp~t is~. EXP~TION OF P~ ~W: If no p~t is is~ ~in 180 ~y~ of~e date of ~pli~fi~ ~is ~pli~fion ~11 (s~ S~ion 107.4 of~e Uni~m ~d~g C~ ~mt ~fion). No a~li~ion cm be mtmd~ more ~ once. I ~reby ce~fy that I kave read a~ ~mi~d t~ a~caHon and ~w t~ same to he a~plicant's respo~btli~ to dete~i~ w~t pe~its are requi~d and to obtain suck DE~ OF FUBLIC WORKN, B~'ILDING I WATTSUN 5.6 1997 WA STATE ENERGY CODE COMPLIANCE REPORT 01/18/80 FILE: C:kkWATTSUN5\kNEWFILE HOUSE ID: SPECK 1986 Site: Analyst: Jurisdiction: ( ) - Utility: Homeowner: House Type: Single Family Floor Area: 1986 ft2 ( Builder: WEATHERBEE CONST. Weather Data: Whidbey Island, WA Climate Zone: 1 The PROPOSED design *COMPLIES* with 1997 WA State Energy Code. ~FE~NCE PROPOSED COMPONENT PERFO~ANCE 353 325 Btu/hr-F ENERGY BUDGET *** *** kWh/ft2-yr ~FERENCE DESIGN Reference Component Value X Area = UA On Grade Slab F-0,540 llOft 59.4 Floor' U--O. 029 634 18.4 Glazing (~ 15% U-O. 400 289.9 116.0 Doors U-O. 200 54.0 10.8 AG Wall U-O. 058 1821 105.6 Skylights ~' U-O. 580 8.0 4.6 Ceiling, Attic U-O. 031 1232 38.2 Infiltration ACH-O. 350 15888ft3( 101.8) Reference UA 353.0 PROPOSED DESIGN COMPONENTS Component Description Value X Area = UA On Grade Slab RiO 4~ vertical F-0.480 llOft 52.8 Floor R30 unrented Joist 16oc U-0.029 6~4 18.4 Glazing C~14% **SUMMIT VINYL HS LOW,/E GAS U-0.360 114.0 41.0 **SUMMIT VINYL PIC LOW/E GAS U-0.840 74.5 25.3 Items in parentheses not included in COMPONENT PERFORMANCE totals. ** Denotes non--standard values - check calculation of thermal value. ....................................... age ~~~~~ WATTSUN 5.6 1997 WA STATE ENERGY CODE COMPLIANCE REPORT 01,/18/80 FILE: C:X\WATTSUN5kkNEWFILE ttOUSE ID: SPECK 1986 **SUMMIT VINYL SGI) LOW/E GAS U-0.360 86.0 31.0 Doors **METAL STANLEY K-5 INSU U-0.028 54.0 1.5 AG Wall R19 STD Lap Wood U-0.062 1836 113.8 Skylights @ **CRYSTALITE VINYL W/ARIGON U-0.370 8.0 3.0 Ceiling R38 blown Attic STD baffled U-0.031 1232 38.2 Infiltration Standard Air Sealing ACH-0.350 15888ft3 (101.8) Proposed UA 325.0 Struc Mass Light Frame, Sheetrock walls M- 3.000 1986 5958 HEATING/COOLING/VENTILATING SYSTEMS PROPOSED Heating System Type: Electric: Zoned System Efficiency: 100 % Modified Efficiency: 0 % Design ACH: 0.60 Design Load(at 46F dt): 22975 Btu/hr Total Load: 22975 Btu/hr System Size(Output): 10.0 kW (15(21%) Average Annual Heat: *** kwh Annual Cost: $ *** Ventilation System: Integrated Spot & Whole House Cooling System: SEER: 0.0 () Cooling Load(at -7F dt): Btu/hr System Size(%Over): tons(@125%) Annual Cool Requirement: kWh/yr Solar Access: Partially Shaded GLAZING ORIENTATION PROPOSED PROPOSED South : ftc North : ft2 Southeast : Northwest East : West : Northeast : Southwest : Eff S Glz: Economic and energy consu~nption estimates are designed for ,comparative purposes only. Actual cost for beating will vary depending on weather conditions, occupant lifestyle and other factors. ===================================== Page 2 =================================== ~. E. 4TH CITY OF PORT ANGELES DEPARTMENT OF PUBLIC WORKS ........... INSPECTION REPORT ........... REQUEST: Date ''~ "~ ~-- "' -~ ~ Time Received by {phone, person) Location of Work to be inspected /g~--~ ~ Name of person requesting inspection Address of person requesting inspection Phone No. Type of/~-~--'--~p~lnspecti°n {circle appropriate one): Permit No. Sewer (Fou~ndati~] Framing Chimney Plumbing Final Sewer Excav. Other INSPEC NOTES: Inspected: Date C:~ - ~ ~ ~:~)/ Tim,e By ~7~ Remarks: RESTORATION REQUIRED ...... YES NO SURFACE RESTORATION: SURFACE TYPE: [] Unimproved ~JGravel []Asphalt E~]PCC []Other [] Repaired by City Work Order # I--}Repaired by Permittee [] COMPLETE I~1 No Damage Found [] INCOMPLETE (Continue on reverse side if necessary) STREET SUPERINTENDENT (DATE) CITY OF PORT ANGELES DEPARTMENT OF PUBLIC WORKS ........... INSPECTION REPORT ........... REO. U:.E~T~ .?~ ,~'~ ~ ~-~ Date ~':'~ ~' ~' ~ Time Received by ~, {phone, person) Location of Work tO be inspected /~'~ :-~ 7- ~ ~ Name of person requesting inspection Address of person requesting inspection Phone No. Type of Inspection {circle appropriate one): Permit No. / Z~G ~ Sewer Foundation Framing Chimney Plumbing Final Sewer Excav. Other .~-, ~-~ /~,~ INSPECTION NO~T/E~S:~..~ . ~' Inspected: Date ! f Time. By Remarks: RESTORATION REQUIRED ...... YES. NO SURFACE RESTORATION: SURFACE TYPE: [] Unimproved []Gravel []Asphalt []PCC []Other []Repaired by City Work Order # ElRepaired by Permittee [] COMPLETE []No Damage Found [] INCOMPLETE (Continue on reverse side if necessary) STREET SUPERINTENDENT (DATE) CITY OF PORT ANGELES DEPARTMENT OF PUBLIC WORKS ........... INSPECTION REPORT ........... REQUEST: Date /'~-- ~-~- ~) [ Time ~/~ ~ Received by ~- ~- (phone, person) Location of Work to be inspected /(o -~ ~ ~ ~-~ Name of person requesting inspection Address of person requesting inspection Phone No. Type of Inspection (circle appropriate one): Permit No. f ~/ ~ c_/~ Sewer Foundation ~ Chimney Plumbing Final Sewer Excav./,f~th--~r 4~'/f,~ INSPECTION NOT. ES: Inspected: Date ~ Z ~/~- ~ Time By RemarksL RESTORATION REQUIRED ...... YES_ NO SURFACE RESTORATION: SURFACE TYPE: [] Unimproved [~Gravel []Asphalt ~]PCC [~]Other [] Repaired by City Work Order # E] Repaired by Permittee [] COMPLETE [] No Damage Found [] INCOMPLETE (Continue on reverse side if necessary) STREET SUPERINTENDENT (DATE) CITY OF PORT ANGELES DEPARTMENT OF PUBLIC WORKS ........... INSPECTION REPORT ........... REQUEST: Date ~-7~Z~--- (~ f Time '/---~" / ¢~"~ Received by f~-~ ~person) Location of Work to be inspected /~ ':~'~-- (:~ Name of person requesting inspection ~ ~ ~ ! Address of person requesting inspection Phone No. ~ ~'~-'~-) Type of Inspection (circle appropriate one): Permit No. t Sewer Foundation Framing Chimney Plumbing Final SewerExcav.(~the~ INSPECTION NOTES: Inspected: Date ~7/~'~>-O / Time /~ ~ ~).~_ By Remarks: RESTORATION REQUIRED ......YES_ NO . ,4 P / , SURFACE RESTORATION: SURFACE TYPE: [] Unimproved ~Gravel I~lAsphalt I~PCC []Other []Repaired by City Work Order # [--lRepaired by Permittee [] COMPLETE ~--I No Damage Found [] INCOMPLETE (Continue on reverse side if necessary) STREET SUPERINTENDENT (DATE) CITY OF PORT ANGELES  PUBLIC WORKS - ELECTRICAL DIVISION ~21 EAST 5TH STREET, PORT AN( ELES WA 98362 ELECTRICAL PERMIT ISSUED: 4/16/2001 PERMIT NO 7218 OWNER/APPLICANT PROPERTY LOCATION BRAD WEATHERBEE 1632 4TH ST E 201 ROBINSON RD Lot: 2 Block: 183 [] Long Legal Port Angeles, WA 98362 360/452-3710 Subdivision: TPA T: S: Parcel No: 063000018305000 CONTRACTOR ARCHITECT DAVIS ELECTRIC N/A 453 WILLIAMSON RD. SEQUIM, WA 98382 , 98360-0000 360/683-3842 360/000-0000 PROJECT INFO Project Type: RES.NEW Project Value: $3,500.00 Occupancy Type: RESIDENTIAL Construction Type: Occupancy Group: Zoning Use: RS7 Electrical Heat: ,.- [] Baseboard 0 KW [] Riser [] Underground Service [] Furnace 0 KW [] Overhead Service Voltage: 0 [] Heat Pump 0 KW [] TempService Phase: [] 1 [] 3 \ [] Fan Wall 8 KW Service Size: 200 Feeder Size: 0 PROJECT NOTES WIRE NEW SFD, FEES ASSESSMENT Service: $0.00 Additional Feeders: $0.00 Circuit Wiring: $110.00 Temp Service: $0.00 Misc Fee: $0.00 TOTAL FEE: $110.00 AMOUNT PAID: $110.00 BALANCE DUE $0.00 ( ()kVx!l~N'I ~/ACTION NEEDED ELECTRICAL PERMIT INSPECrlON RECORD CALL 417-4735 FOR ELECTRICAL INSPECTIONS. PLEASE PROVIDE A ~ 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE IT !$ INSPECTED AND ACCEPTED. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE DITCH ROUGH-IN / COVER SERVICE FINAL I s<'~</~i I r'~ I GENERAL COMMENTS: ~"-~ .~. ~- CITY OF PORT ANGELES PUBLIC WORKS "BUILDING DIVISION 321 EAST 5TH STREET, PORT ANGELES, WA 98362 /~5Z E 4~ PUB/LIe WORKS & R/W PERM/T o Attached Notes OWNERIAPPLlCANT BRAD WEATHERBEE 201 ROBINSON RD Port Angeles, WA 98362 0001604-2310 PROJECT INFO Work is: Plans Required: Contractor: OWNER Performance Bond Required: Proof of Insurance: Work to Perform: Issued: 4/17/2001 Permit No: Work Order: 1140 o Value Work: II Finish Date: 2061000-0000 PROPERTY LOCATION 1632 4TH ST E Lot: 2 Subdivision: Parcel No: TPA 063000018305000 Block: 183 o Long Legal Start Date: Amount: ~ Install o Repair ~ Watermain PROJECT NOTES $0.00 ~ Sanitary Sewer o Storm Drain o Underground TelelElec ~ Mise $0.00 II dwy FEES ASSESSMENT 1.) RIW Excav: 2.) Sidewalk: 3.) Curb/Gutter: 4.) Driveway: 5.) Dwy Culvert: 6.) Street Cut: 7.) Other RIW: 8.) Fire Hydrant: 9.) Res Water Serv: 5/8" 10.) Comm Water Serv: 11.) Other Water Service: 12.)Water System Dev: 13.) San Sewer SFR: 14.) San Sewer MFR: add unit: $45.00 $0.00 $0.00 $145.00 $0.00 $230.00 $0.00 $0.00 $640.00 $0.00 $0.00 $1,025.00 $95.00 $0.00 o . Receipt No: Inspection Fee: RW 6950 $0.00 WATER SANITARY 15.) Other San Sewer: 16.) Sew Tap WyelMan Tap: 17.) Sew Capl WIM Removal: 18.) Alter Repair Sewer: 19.) Storm Drain: 20.) Catch Basin per ea: 21.) Sewer System Dev: 22.) Milwaukee Dr. Sew Ass: 23.) RIW Use Perm: 24.) Admin Cost (D.R.A) 25.) D.RA 26.) Mise: TOTAL FEE: Amount Paid: $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $745.00 $0.00 $0.00 $0.00 $0.00 $0.00 $2,925.00 $2,925.00 . Balance Due: DWY STORM $0.00 DRA OTHER Separate Permits are required for electrical work, utilities, private and public improvements. This permit becomes null and void ~ work or construction authorized is not commenced within 180 days, ~ construction or work is suspended or abandoned for a period of 180 days after the work as commenced, or ~ required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Sinnature of Contractor or Authorized AQent Date Date Sinnature of Owner err owner is builder) CITY OF PORT ANGELES DEPARTMENT OF PUBLIC WORKS . . . . . . INSPECTION REPORT. . . REQUEST: Date Time Received by ~,.-- ~rson) 11032. R 4~ l' )~~H-L> R- J S \J C-.-> Phone No. Permit No. 11-4 () Location of Work to be inspected Name of person requesting inspection Address of person requesting inspection Type of Inspection (circle appropriate one): 8 Foundation Framing Chimney Plumbing Final Sewer Excav. Other INSPECTION NOTES' m h . Inspected: Date 4/2- -=s 112\ Remarks: Time J{),3CJ ftn1 By ./fAt! C no'Yl p (e:k, ^f!J RESTORA TION REQUIRED. . . . .. YES p,,:s-r- vJ1 e 'i'ct-p ,,,.I (()- NO )\ , '.I ~ .l:. " ~,~ ~ \:::' ~ / SURFACE RESTORATION: SURFACE TYPE: 0 Unimproved OGravel o Asphalt OPCC o Other o Repaired by City [] Repaired by Permittee o No Damage Found Work Order # o COMPLETE o INCOMPLETE (Continue on reverse side if necessary) STREET SUPERINTENDENT (DATE) b"-' - ~ DC> I - 18 :3" CITY OF PORT ANGELES DEPARTMENT OF PUBLIC WORKS . . . . . . . . . . . INSPECTION REPORT. . . . . . . . . . . REQUEST: Date [1_ ~ \.{ - 0 I ~ ,,..: Time Received by (phone, person) Location of Work to be inspected Name of person requesting inspection Address of person requesting inspection Type of Inspection (circle appropriate one): Jb 5 '2 E- If-fl1 /1-e VYf W'I \ Ley 11 Hi 'tr J1, Phone No. //<10 (;..)Ci. f-er Permit No. Sewer Foundation Framing Chimney Plumbing Final Sewer Excav. Other INSPECTION NOTES: Inspected: Date Time Remarks: t: IV Sk II f\te- u \ ~ /V{ J /2 ....JL By I y ~h LuCL--f----e/)-- I RESTORATION REQUiRED...... YES / NO I~ ft~i r ~ ~ ~ C; ~~ , ( ;;l."e~ 96 4--r , I 1 r I. SURFACE RESTORATION: SURFACE TYPE: D Unimproved DGravel D Repaired by City D Repaired by Permittee D No Damage Found D Asphalt D PCC D Other Work Order # /9J~ ~MPLETE D INCOMPLETE f f:nntinuA,nn.rAverse.side.if.necessar.v.l C'''I''n~~''I'' C"llnr-r..'u...r-Iu....,......... lro. A....r-l ~ '. Dtv-2oo1-tB ilG. f- . APPLICATION FOR WATER . City Water Department ~ ~ Part Angeles, Wash. I'/} ~t?/. -", . I hereby apply for water to be Furnished in accordance w.;th rates c:nd rules of the City for the Following premises: Name of Applicant 4-L1 /~ . /r!/Jfr e t1 r71 Renewal 0 New Servic.e G-:'~ Blk /(3 LOLL / 'V.5 II Size of Service /\ Meter Number Service Left On 0 Servic: Left Off Iti Signed Installedby -rW ~-ooo 0 (,0 ?'-fl"ffl/r-::;ll /1#lJ /.AO~+ /oes'le Remarks: "7(ec;-'di- tJ;qSV tp'-rl / r.n4;~~ ( ;;?J / ,f',11 U~ .I?J .4>.-rr Address